Document NyaaEenwbw9Z3xJ69eZrQd2D

CM.102* *CV UTUtJlNC id E. I. du Pont ds Nemours & Company iMOP0*rt3 Wilmington. Delaware 19898 ENGINEERING DEPARTMENT LOUVIERS BUILDING June 13,* 1972 . j. nines or Emp. Eel oubcomei w v e e Memcers J.L. Anthony - ERD H.A. Heideiberger - Design Refer to Serial Letter lC13 Dated November 8, 1972 P..D. CARLTON, B IOC HEM., V.'ILM. (2) E. E.ROBBINS, CENT. RES., EXP.STA. (2) H.F EATON , ELASCHSM, VILM. (9) J.u.BRECKENRIDGE,EKP.REL.,VILM. (1) C.S.ELLER, BMfcID, LOUVIERS (1) C. 0 .BROWN , CONSTRUCTION, LOUVIERS (1) R.F.STEWART, DESIGN, LOUVIERS (8) J.P.KLIKCWICZ, ERD, EDL (1) F. J.MARTIN, ESD, LOUVIERS (1) H.H.hOHL, F4J, WILY. (12) V'.E.NEFF, FILM, VILM. (7) V..H.MC COY, IND.CKEM. ,V:iLM. C.W.ANDRUS,INTL., VILM. J.V.FLYNN, ORCHEM, CH.VKS. J. J.LAURINO,PHOTO PROD.,VILM. R.H.MC CONNELL,PIGM.,EDGE MOOR K. V.'.DAHL, PLASTICS, VILM. T.C.HILL, POLYMER INTER., VILM. H.G.SHULBY,PURCHASING,LOUVIERS J.A.SIGMAN, TEX.FIB., VILM. R.H.GRUSS,REM.ARMS,BRIDGEPORT iu (1 (6 (5 (6 (7 U- (2 (2 (2 dTAN'DARDd SECTION - SAFETY L FIRE PROTECTION SUBCOMMITTEE ouT - MEASUREMENT AND CONTROL OF ASBESTOS DUST EXPOSURE This standard was approved without comment by the following departments: ElaiChem, Employee Relations, ESD, FScF, International, Film, Pigments, Purchasing. In addition, the following comments have been received from the Engineering Standards Committee. These have been reviewed by the subcommittee, with replies as shown below. Comments have oeer. arranged to put like replies together due tc the number involved, rather than the usual procedure. vH '*^7' '<'* i COKMZNTS BY R. D, GCTWAL5/W. S. PERoON - ORCHEM "oes the TLV (S2T) meet proposed Federal limits': aKS . REPLY - The thresnold limit value (TLV) for asbestos listed on values of American Conference of Governmental Indust A new, mere restrictive limit for asbestos has been included regulation promulgated in the U.S. Federal Register of June 11313-11322. Both ^ZT and B^T must be changed accordingly. i 'L. * L 4^, orrna: n . dwir.? .AURINO - PHOTO PRODUCT.; cmmer.d tr.at tnis standard not be issued r.e part covered fcv OSHA is in use. o2T was based .1 Hygienists. the OoHA_ 1972, pages e new FIY - standard has seen delayed as you suggested. Also, see reply tc Comment -Nc . 1. he part covered by 05HA will be printed in red. a ^ Mu PA V^CsI /R . FIoH--R - IND. CHEM. - r.~ r r.i i. u CK. .i-_ tnis concept e. extended to axf insulating materials and v u- a5C6StCS b.ar.y insulations contain nc asbestos cu: are dusty an. fioro-u. Il.culat.ic5b containing silica, altr.oug r. _es V lx X IL w can cau_e silicccis and cr.rcnic lung disease. DUP 1153852 DU 062080 11/3/71 June 13 , lv72 * r> IS S C an si 3.FIS ^.UnitSC. t,0 ^S38 wOS* uuf.Sr IRSU^ awiHn 1713 t>Sri3.*.3 , alcr.ouun uusty "ana cicrous, do ncc ccn-ain carcinogenic material. \ -- " w A >>'0 W i s:\op cper acicr. ns scmewnat out erent, ircn '^* r*-** j . *pelinos in .itiut oncu^d we now mention ^he acoxicat^cn ;; this stanaara nn liexa worx as weilV *3 inter.xea as a guide. :cr a^j. .cases ci asoestos exposure incl--in.: iielu v.or<c, as outlined in tne scope. -- a 1 .m.ec . r* ..:..r'i ? _ cream/' ^ W.-. ^ -V p n '/ "770^1' ~ v _ mrv rrq . pT r. - - - - -- v o_.__: - - .;us we:;*:^ a.own o: msuxaticn sncuxi carry a -efrain Iron, wetting aowr. net lines where: a) water ccula be ,c w.-.cr ani cause ourns; o) water ccula fracture pipe or cy water couia ireeze out or siow aown process f^ow m i! o, n lines. . r_ - ,,eti ucwr carriea out on lines that are sti^.* insuxatea, tr.erefcre oirect conca. t ny the water should net create a prooler.. wording 'aIx- ce cnan.gee wet aowR". supervision snouxu review -.iu-uu* voCwuacicrs COMLIHT M. 6 - 6.1.1 - Sacr. area group of insulators at Ola Hickory are asKea to tn.-.e at .Least one sample (not necessarily of 8-hr. auraticn) on a different jeo eacr. wee.<. ('.ore samples are requestea when there are indi cations of any' change ta.cin~ place or new types of materials are being tried .nis type of sampling provides us with new data in some jo os ana shows results of our efforts to imorove .dust control in other jobs. c.-.* -"rruli 8-hr shift not necessary-one nr is sufficient, * *y -> p * n -s . n*y >** * O - C i jUjw i *" x w^V 'f K *> r* ' " r.n ill xiO ^ n- i. xx rv> x __. - c.^.*. - question need :or sampling eacn operation :cr a I _ ;uiit monthl". Many operations are not continuous ana 3-hr ;-1: is impractical. Also, sampling can show TLV limits have never been mcoe^ou in c-particular operation. Some samples should be taken monthly, mere _emi-r.outr.ly, or annually. .. sy w. fading - tsx. fib. - /::;stc;; ?la:.t cisapp.) 6 . * . ^ we are taKing ^ eignt-nour samples mertn^v as a 'r.istrocia* fi^e . OU..w *" oartcu.ar*rn sneu-j oe carneu ter 3 rr.cr.w*r.-.v i.or equivalent,, usuailv is -- w- r\ ^ ',,(,1 n . 1a*uau*r,g mi cctp x6t8 cperaticn m tr**s nannen wich "i*lipore (meriorane) paper, or ics 01 snor luration (10-15 min.) because of tne higr. OUP IJ53853 DU 062031 H/3/7 3 197 2 collection efficiency of this paper, ouch a procedure, as described, might involve taking'many samples for an 8-hour shift for each operation. It 815.10 per sample for analysis, the cost of this operation will exceed tr.e cenefits, since the results cf these analyses are not known for some ti ant any reference to the TLV for that work period will be meaningless, ouch a program of sampling could be satisfactory provided the work con ditions do net change. Respiratory protection must be required in ail case; where the degree of exposure is unxnown. REPLY TO COMMENTS 6-11 - Right-hours' sample is advisable in the prelim inary sampling in accordance with frequency ana pattern by 15HA. iuosecuent samples may oe tailored to'the individual needs of the location, c.l _ revised accordingly. C. i. oilHAN. COMMENTS 5Y ?. . M. 500NS - TEX. FIB. - DORDRECHT CoV-VnNT Kl. i2 - Change 5.2 as follows: "Clothes must be kept free cf dust accumulation. Clothes contaminated with dust shall be vacuum-cleaned before taking them cfiT avoid breathing asbestos dust when removing clothesH. Sei more speeme at this point is desirable. 1. A. 5IGMAN, COMMENT 3Y W. R. CLARK - TEX. FI5. - SEAF0R1 PLANT COMMENT NC. 13 - 5.2 - Intent good - but how and' to what extent'1;" .REPLY TO COMMENTc 12 AND 13 - We do not agree the underlined sentence should be aaaea. Specific teenniques for removing dust accumulation from clothes should be developed locally. Vacuum cleaning is one way, but it may net be the Dest method availaDle. '.A. cIGMAN, COMMENT BY W. R. CLARK - TEX. FIB. - 5EAFORD PLANT COMMENT NO. lu. - 3.1.2"- omit. REPLY - This is considered a large source of asbestos dust; therefore we feel it is necessary. COMMENT NO. 15 - 3.1.3 - Include vacuum or respiratory protection. Should be done cniy if sample analyses so indicate. REPLY - Subcommittee prefers current wording. COMMENT NO. 16 - 3.2.1 - Recommend use of respirator with or without exhaust system. REPLY - ivs sc not fee 1 that a respirator should be required when it is net necessary. Requirements cf Sect. <+ will determine need. 0KMEN7 NC. C 3 - Assume portable vacuum cleaners are acceptable. REPLY - Yes, also see reply to comment No. *5. J. A.-.IGMAN . COMMENT 5Y a. R. CLARK. ( CON ' T . ) CIMKENT ~]iC. u3 - 3.J .I - ft'ny not eliminate use of asbestos cement? Use Tower" House cement, which contains no asbestos. DUP 1153854 DU 062082 saasar ftifUfilMif iftiiat-j lagfe-iai.... I,mi i'iifl'*5*1 ' "jj-Sw. ,1. ^CI3 11/3/71 4 June 13 1972 J.A. oIGMAN. C0MML..T BY/'J. M. MARTIN - TEX, -13. - CHATTANOOGA PLANT COMMENT NO. i9 - Asbestos-cement should be avoided whenever possible. REPLY TC COMMENTS 13 AND 19 -2.7 encourages the substitution of nonasbestos bearing material! wherever possible. J. A. EIGMAN. COMMENTS BY V. R. CLARK (CON'T.) COMMENT NO. 20 - 3..+ .1 - jo not recommend wetting down. vacuum before removal and-for job cleaning. Do recommend J. A. SI OMAN, C OMMEN TS BY_ V. M. READING (CON * T,) COMMENT N'0. 21 - 3.4.1'- Impractical; would create a slipping hazard. Also, lit. .ssibl'e to protect electrical equipment. There is little likelihood that this would be done unless a most elaborate and unusual precautionary pro cedure was followed. J. A. SIOMAN. COMMENT BY A. PAETSCH (CON'T.) CQMFEKT'KO. - Insulation will be used more than one time. Wet insulation cannot be used. Insulation with finish is water-resistant. COMMENT NO. 23 - 3.4.3 - Area should be cleaned with vacuum system. Water should not be"used. REPLY TO COMMENTS 10-23 - We consider wetting down the desirable technique. Local conditions may indicate other control measures. "Wetting" changed to `damper. J. A. SIGMAN, COMMENT BY W. R. CLARK (CON'T.} COMMENT NO. 2l - Add- where dust problem exists (5.3) J. A. SIGMAN, COMMENT BY W. M. READING (CON'T.) COMMENT NO. 23 -5.3 - We have not insisted on this. ment is questionable. Practical enforce J. A. oIGMAN, COMMENT BY A. PAETSCH (CON'T.) COMMENT NO. 2 c - - Gum or eat mg-tobacco can be consumed in working areas oecause oreath-way will be kept wet. No smoking. No food. REPLY TO COMMENTS 2--26 - Food, tobacco and gum should be restricted, since dust concentrations are not always known. J A. -I3MAN, COMMENT BY P. F. PKILTAW - TEXTILE FIBERS'- WAYNESBORO PLANT COMMENT N. i.r - 5.3 - Adherence to this item" will create problems in that alternate facilities must be provided which will result in lost time from the job. Lr.less there is a clear need for this item, it should be deleted. REPLY - Tim restriction is recommended tc prevent ingestion of asbestos particles into tne system orally. We consider it is needed. J. A. wICMAN. COMMENT BY J. M. MARTIN (CON'T.) (COMMENT NO. IS - Not necessary to isolate power cutting equipment in a separate worn area if adequate exhaust system is provided. REPLY -- Ot 5. A ..re-a. -n -.-equate exnaust system will eliminate the need for G_aticr. o;' tne equipment. DUP 1153855 DU 062083 w M V' k. , 73/' - .5 972 . IOMAN, :QWGu.r 3Y J. H, MARTI:: _( CON TT, ) vj *1 - 01 xluwejowtiwonu necessity cf extensive aaily clean-up; gcou *, w snouia be exercised for frequency of clean-up. REPLY - Daily clean-up is strongly recommended. J. A. oIGMAN, COGENT 5Y W. K. READING (C0N;T.) COMSKT liD. 30 - In general, we believe that the stanaard is basically gooa tut unrealistic. We would, at best, require a major modification of our equipment ana procedures to comply. REP I _ - We unaerstar.a that a major modification of equipment ana procedures ma ce recuired; however, we celieve the stanaard is reasonable when con- worker health and OLHA regulations. Also, see reply to Comment ho. COMMENT NO. 31 - '.'either vacuum or mask are believea to be necessary(313). REPLY - /acuum cr respiratory protection is considered necessary since this operation is a major source of airborne asbestos fibers. COMMENT NO. 32 - Would like to know where to purchase and what type of insu-ation is available. We cannot accept Unibestos (3.1.4). COMMENT NO. 33 - 3.3.2 - Would like to know where this type of cement could De purcrarea. REPLY TO CCKMENT5 32 AND 33 - This information is being included in insulation specifications. Contact the Insulation Standards Subcommittee. COMMENT NO. 3u - 3.2.1 - Our saws are not isolatea, but we have not been above the 117 in our tests. Our exhaust system performs very well; however, the dust is not wet down.. Adjacent carpenter shop's outside exhaust system is tiea into same system. Contents from cyclone drop into closed dumpster, dome fibers are lost in cyclone air exhaust outside of the building. REPLY - oaws must not necessarily be isolated in the sense of partitioning off. They should be in a separate area and the efficiency of the exhaust systems measured to assure they are functioning properly. (Eee Comment 1.) | COMMENT NO. 35 - 1.1.1 - We do not believe this is necessary, but the ! information is pertinent. N. COMMENT 3Y w. F. DOBBS - 3I0CHSMICALE_ - "LL* i-- r --" T * \' _`_2 - 32 - Relieve s/ome exception sncu- a be maae to requirement permitting small' amounts cf insulation to be remove i respiratory protection. Can a rule-01-thumb quantity oe stipulat will not res ult in exposure to higher than permitted rPT \T ^ - r- * removal of i nsuiation not requiring over 5-10 minutes be excepted - ** cr without wmch cien^ ceaure r--"C, TMMENTs 3 AND 3o - Local conditions should be monitored ana estaoaisr.e in icO ro' ^ns* 'i/a- er^ation of ctner sections of ^ wa.rw.ar -- 0- DUP H53856 DU 062084 11/8/71 6- - <j UH6 > 972 J. A. a IGKAN . COMMENT BY n. PAET3CH ( CON 'T. ) rpRMZKT^ib'. 37 - 2.3 - Standard d2T should be in conformity to the latest threshold limit values (TLV's) or to the limits of German authorities (otaubforschunginstitut). REPLY - S2T is revised annually to conform with latest TLV's. See reply to comment No. 1. COMMEND NO. 33 - 3*1.5, 3*4*1 - Design of proposed work table is required. COMMENT NO. 39 - 3*m-*5 (New) - If possible transportable work-table with vacuum. system should be usea for working in the areas. REPLY TG COMMENTS 38 AND 39 - Tables should be designed to meet .local needs. COMMENT NO. uC - 3*4.2 - Which dimension should the area haver REPLY - Dimensions of the area would be determined by monitoring. K. .v, rAHL, COMMENT 3Y C. C. PRING - PLADTICE - SABINE RIVER WORKS COMMENT No. *A~- We woula like to nave suggested sampling equipment aaaea to the standard. W. H. VC COY, COMMENT BY W. 0. CHRIbTY (CON'T.) TZWZU 7 Mr~l'2 - 274^ - Sampling fibers and particulates can differ. The cattery-operated sampler approved for fiber sampling should be specified to include millipore filter. COMMENT NO. ^ - 6.1 - Suggest clarification of this statement. Recommend addition o:i: "with a battery-powered personal air sampler". Suppliers of such samplers are: The Mine Safety Equipment Company, and the Union Industrial Equipment Company. COMMENT NO. -** - 6.1.3 - Asbestos handling is now recognized as an extremely serious industrial hygiene problem. Analyzing asbestos samples is necessary. But the prooiems in sending samples several hundreds of miles by mail should be pointed out and the importance of correct handling emphasized. Some of the prooiems are: transportation of samples may cause damage to the sample and possible loss of sample; delay in receiving results. This will, prccabiy, be inevitable with laboratories receiving many such samples. Expensive as it may appear, the alternative may be to do local monitoring, use local laooratcries, or to utilize the best engineering and personal protect! measures available. R Y4DTA- TC vJDKMENTD - We recognize that fibers and particulate sampling "a iTers. Haskell Laboratory will recommend appropriate pump ana filter , or various applications. DUP 1153857 DU 062085 - *+w i ,, 11/5/72 <- uRc _ ^ ) *v7 2 Type cf vacuum cleaner and filter should be specifier. Without nigh efficiency filters, this cleaning operation will filter cut all particles ana fibers, except those in the respirable fraction. RnPLY - Type of vacuus cleaners and filters will vary with location, ivaxnation shouli oe mate and selection based on local need. COMMENT NO. -.6 - }.i.j - Type of respiratory protection should be speciflea. COMMENT NO. *7 - 3.*+.2 - specify suitable respiratory protection. HI?' TC COMMENTS *.c A.'.'l *7 - Requirea type of respiratory protection is specified as that wnicn complies with 3ureau of Mines Schedule 21B, see *+.1.2 There are various manufacturers who make an acceptable type. COMMENT NO. -+3 - *.*.2 - A reference to U.5. Bureau of Mines Schedule rare *h-, Suopart A, item In.*, minimum efficiency C.3 micron is neeaea. several suppliers of respirators that meet this requirement are: Acme Protection Equipment Company American.Optical Company IsO* haiamazoo otreet oouthbridge, Mass. South haven, Michigan Mine Safety Equipment Co. Bradaock, Thomas, and Meaa Streets Pittsburgh, Pa. REPLY - All requirements of Schedule 21B must be met ana we should not pinpoint the part ana suopart. We will delete the effective filtration range to avcia possible confusion. COMMENT NO. *9 - 3.1.3 - This operation can still produce oust in breathing zones unless carefully controlled, perhaps a self-closing damper on the shuts or flexible self-seaiing slot. HZ PLY - Some aust is inherent in all operations. If this is above the acceptaole TLV, respiratory protection should be providea. ^CMKENT N0. -C - 3.2.2 - "An adequate exhaust system" should be aefinea. minima* exr.aust rate per fan shoula be specified. Our experience snowea that, aesyite exhau*t fans and no appearance of austiness, the TLV still was exceeaea. Suitable protection is not aefinea. Consideration shoula be given to exposure of other people in the work area. REPLY - -n aaoa-ate exnau*t system is one which maintains asbestos fiber concentrations oe*ow the acceptable TLV. 3.2.2 revised. COMMENT NC. 31 - 3.*.* - We have found no plant or governmental regulations governing tne aisposal of asbestos. REPLY - OSHA Regulations recently issuea on an emergency basis, ana new perrr.ar.er. z , r - ' ^ c z: 0 j i socsal cT b.s'dsszcz ^0*8 F 0 a 0 r a 1 Rs^iCw^r rsfsrsr.zc ' ~ DU 062086 DUP \ 1S3858 .1/3/ (1M 3 u une 1972 tec: res-. c, ~ 2 - *. 1 - This rule really says always- wear respiratory pro- wnen nandiii.a asoestos. oamcies are sent away for analysis ana are Known long after the fact - too long for corrective action. F.f FIT - Respiratory protection.should ce provided until sample results are receives ana it is established that TL7Ts are not being exceedea. v. H_. -.1 CCF. COMMENTS ST J. PAV'LOoRI/R. FI5HSR - IND. CHEM. - REPAUNG WQftKd CC.MldhT NO. zj - In paragraph 2.1, spray' asbestos for insulation ana fireproofing should be aadea as this is discharged directly from a hose to cue a-mesphere. Contractors sometimes ao this work at Plant sites and aaecuate isolation cf the area is advisable. J. dGXAN. JOW'ZDTs i: 3. 3. KIRKPATRICK (CON'T.) C0Ma.d' ,U. d - 2.2o - "Opening coxes of new insulation" should reaa, 'Opening ccxes end stocking oins from new boxes of insulation''. Ola Hlexery has maos repeatea sampling tests cf this bin stocking operation ana fount them over TL/ limits. Our safety rules are being changed to induce this operation where dust respirators will be worn. CONMn.'T NC. 5 5 - 3.1 - This may nave to be rewritten to harmonize with comments above for 2.2o. C3>iMi&T iNO. ;6 - Dust respirators are to be worn anyway when removing insulation (2.2c). J_. -IDd.iN, 3Y F. E. M. UPON5 - TEX. FI3. - DORDRECHT COMKRNT DO. 5 7 - Change point 3.1.^ as follows: r*Glaze coating on block insulation reauces asbestos as a potential dust source". Available or not available is of minor importance here. ;3 - Add to 3.2.2: "Consideration also must be given to exposure cl other personnel working in the area who are not directly involved, The same warning has been given in point 3.4.2. To our opinion * it applies here, too. J. d did.:;. COMMENT 3Y W. R. CLARK (CON'T. ) COMYEd d. \i- 3.1.5 - jo not agree - Use cf vacuum cleaner to clean up wcrxter.cn. Use of plastic bag oxay, but question value of wetting bag unless none continually. This is not practical. J. n., dbdn. COMMENTS LY ?. F. PHILYAi (CON'T.) DlYXEhT oC - 3.2.1 - Asbestos oust does not precipitate readily ir. cyclone collectors. A bag filter for asbestos dust should be required. A' *1 A M w U'JL.i . MARTIN I r t -- j ou - meter t c wear protective equipment when stripping insu^at iC.n aoner than we ttins sc that insulation can be reused. t. <J r. w ^ -dd-w* .* v * `r n f r> r\\x f m \ . 4. I ft > j* , X U j -> Uii i. / uOMfcBhT d. s2 - 3.1.3 - We are not using a plastic bag or wetting the scrap cecause of slipping hazards and housekeeping problems that would oe create:. fed re yenc _y crusr. waste from taole top into paper arum, for dis posal ar.d :c net -daw accumulations to build up. DU 062087 DUP 1153859 11/3/71 -9- June 13, 1972 5 v s w err. acscrce man, comment e Y A. PAETSCH ( C ON ' T.) ^- J._.y, 3.s-.- - lust should be eliminated through vacuum ^vetting seems not tc be successful because fine dust cannot be t .trough water and will reduce the effect of the cyclone. COMMENT NO. 6u - 3.2.1, 3-u.l - Dust should not be wetted (see 3.1.5). lust collecting bag should be closed ana thrown away. Vacuum system should ce uesignea for using one-way bags. R. /. uTEaART, COMMENT 3Y . 3. HALL - DESIGN - LOUVIERS CCl-C-ITT h'O. c5 - Suggest paragraph 3.1o be reworded as below in oraer to sfilct parallel construction and improve clarity; - Asoestos insulation blocks should be handled with care. If dust cannot be removes oy vacuum, respiratory protective equipment must be used1. a .. . xc ccy . by a. o. ckristy {con *t.) COlNfZENT NO. bo - 3.2.1 - Experience with cyclone collectors for asbestos indicates they are inefficient and in some instances cause atmospheric pollution. CONMuNT NO. b? - Air sampling will not control dust. Air samples should oe taxer, tc oocument the adequacy of controls (3.2.4). COMMIT NO. 68 - 5.1 - Recommend addition of: "and should be disinfected alter earn use''. (See 52H). COMMENT^ A 0. . o9 - 5.2 - Recommend addition of: "wear respirator when removing dusty clothing". REPLY TO COMMENTS 33-69 - The standard will be revised as suggested. R. 0. CARLTON, COMMENT BY J. A. FLATTMANN - BIOCHEMICALS - GRAoSSLLI PLANT COMMENT hi. 7u - Will probably have to incorporate some of this into Plant Safety Instruction. COMMENT N 0. "1 - Ii this comes under OSHA, we will also have to cover in arrangementc with insulating contractors. J. -TOMAN, COMMENT 3Y J. M. MARTIN (CQN'T.) COMMENT .,3. 2 - Kot necessary to wet insulation when emptying cyclones if iiicr.ar'o : into a plastic bag and sealed. o .i 7r-* in COMMENT -- V V 3-- A -- T'n Oi ft 9 i*. * Pi LS 41 (CQN'T.) Insulation is lifted from boxes ana cartons put COMMENT NO. 7- - 3.2.3 - The ledges, lights, inside of storage cins are "cleaneu cr. ^ weekly schedule. Other parts of work area are cleaned daily or more frequently. DU 062088 US38*>0 OOP -WMtiiUSstir rr *+W - J> :i/s/n 10 J une _ 1972 0OMMEN7 N0. 75 - 3-2.h. - We are using Mine oafety air sampling pump with the Miliipore filter type Aerosol Cat. MAWG037A0 pore size .3. The pump is oattery powered. COMMENT NO. 76 - 3*3.1 - We are using Eagle-Picker ouper 66 which conforms to Commer ciai_o t and ar d C.E. 117-u9 issued by U.b.D.C. COMMENT NO, 77 - 3.^.2 - We are barricading the work area to Keep people cut. certain amount of dust inevitady drifts outside of the roped off enclosure. Infrequent large removals have created considerable rust at times. 00" -ENT NO. 73 - 3.u.3 - We are putting our scrap insulation in boxes and cans but not wetting it down, nor do we believe it necessary to do so. COMMENT NO. 79 - 5.2 - The men wear coveralls when working; however, nothing is oeing done to keep them free of dust other than a brushing off from time to time. The statement is ambiguous. COMMENT NO. 30 - 6.1.3 - Samples are sent to Felix Stein, Department of Occupational health, University of Pittsburgh. J. A. JIGMAN. COMMENT BY A. PAETSCH (CON'T.) CTEE?m>pr -ar~~2".4 - Sample for asbestos fiber analysis may be obtained by using an instrument as it is used by German authorities (Staubforschungsinstitut), i.g., Konimeter. COMMENT NO. 82 - 3.2.1, 3.4.1 - Working area should have a little vacuum in order to keep the ad.jointed areas free of dust. COMMENT NO. 33 - 3.2.1, 3.4.1 - Exhaust system should have provision of keeping work place free of dust. COMMENT NO. 84 - 3.3.2 - Not possible because the whole quantity cannot be used at any time. H. H. KOHL. COWENT BY W. H. THOMPSON - F & F - PARLIN PLANT 0OtGCENT NO. 85 - This is not necessarily good measurement on the Plant *evei in as much as this standard will probably form the basis for Plant standard Practices or Standard Operating Procedures, which will take precedence from then on. Without a standard on this subject, local practices will vary from no protection to unnecessarily involved protection. This Iooks like an excellent guide from the Plant standpoint. W. H. MC wOT. COMMENTS BY W. 0-. CHRIcTY (CON'T.) COMMENT :.C. .36 - 3.1.- - Qlazelcoated insulation is satisfactory until tne coating is penetrated by cutting blocks. COMMENT NO. 37 - 3.2.3 - "Avoid sweeping" - this should be a positive rule. Do not sweep. DUp 1153861 T>tS 062089 11/3/71 - II 3, 1972 M. 33 - 3.3.3 - Respiratory protective equipment should be rtorn wr.er. disposing of old asbestos cement. TO COMMENT., 70-33 reoutrej. Your comments are appreciated. No action io sixteen engineering Standards Committee members aavise an estimated tota^ ci 245 uses for this standard as reference per year. aocve. (fl er.ce of additional comments, which should be received oy 72, this standard will be issued with the revisions shown DESIGN DIVISION standards section o Z, SiK " K C. E. Marsh Senior Standards Engineer DUP 1 153862 DU 062090