Document NgGk8ZROZDpDKgE5xORyJovR

TOWOLDMONOQ24608 Why Therminol? Does your process require indirect heating -- that is, high working temperatures delivered to remote "user" locations without tlame? Perhaps your process requires indirect healing and cool ing within the same system. Or, maybe you'd like to get more out of your process heat by us ing it in a nearby space healing application, as well. There arc a number of ways to get these jobs done. A common one involves the use of a pres- This Dutch tanker uses a Therminol system to heat living quarters ss well as cargo. Apartment buildings, offices, hospitals--buildings of all kinds find Therminol an economical alternative to steam. surized heating system -- water (or other liq uids) heated to the vapor phase and transferred under high pressures to the user. But there are drawbacks to this type of indirect heating. Cost ly, often complex equipment, for one The need for licensed boiler operators for another. Then, loo, high operating pressures pose some very real safety problems. That's Why There's Therminol'*' Heat Transfer Fluids With Therminol fluids, you discover the best of all indirect heating worlds--high and low heat ranges, thermal stability, and efficient heat trans fer without high pressure, without the need tor costly equipment, and without the need for con tinuous observation. Therminol fluid heat sys tems offer you the most dependable, most effici ent indirect heating and cooling your process dollars can buy--and this booklet tells you why. Several resin kettles with various heat needs can be hoaled from one Therminol system. Petroleum processors, both on-shore and off-shore, enjoy increased heat transfer safety with Therminol Rolls in rubber, plastics, textiles and paper get uni form hoat with Therminol. Therminol brings uniform temperature control to tex tile processing and finishing. 01739 78 TOWOLDMONOQ24609 f Whal makes Therminol right for your application? Hundreds ot customers who have specified Ther minol for new installations and conversions of ex isting systems will give you these answers. LOWER CAPITAL COSTS | Without pressure you can save 25% to 50%. That's because you don't need heavy piping, relief valves or other high pressure devices. LOWER OPERATING COSTS | Fluid make-up is generally not required. Heat losses are reduced over vapor phase systems because condensate sub cooling is not present. Routine maintenance is minimized and these non-pressured systems re quire only minimum attention by non-licensed per sonnel. V TOWOLDMONOQ24610 m <iiH |n<c.<inci and finishing - whore close temi , :,.:uic r finlrol ir. a tiiur.l is a "nalural" for Tlieri'. with no need lor venting. high operating in-:., and continuous observation. You'll be surprised at how easy it is to woik with a Thcrminol heat transfer sys tem. The middle diagram at the right shows typical Therminol liquid heating and cooling systems used together to maintain very close temperature control at the user. Note thal the term "heater" is used rather than "boiler" since we do not boil Therminol in the primary heat source. Benefits of a Liquid Heating System You gain a wide spectrum of benefits with a Therminol liquid heating system. In many locations, codes favor Ther- minol systems, thus minimizing the need foi expensive operating personnel. Positive circulation through your users ends venting problems; the system re mains scaled and flooded. Liquid systems respond more rapidly to your system's load changes. Install your users at any level in relation to the heater; there's no condensate re moval problem. You realize a substantial cost savings with smaller pipe. Also, smaller valves control temperature more accurately-- down to :* 2F. No temperature loss due to pressure drop in the piping; with vapor, any line friction loss results in a lower vapor condensing temperature at the users. You can meet different temperature de mands in the same user if required 'by certain processes by adjusting the cir culation rate. A liquid heating medium, like Ther minol, will usually give you higher heat transfer rates in certain types of users, such as shell and tube heat exchangers. Cooling can be handled in the same system. Heating systems for Therminol arc sold around the world on a compet itive basis. Contact your nearest Mon santo office, (fisted on the inside back cover) for information anb recommen dations on the Jieating equipment that will fit your particular need. the (('liver.mu of the IVlmit Uivei lloufir* Ooopoi<111vi lioin Mciim k'llm. K> Itieimmol tio.'ilmg ;;;ivoe; S.ab.ODO ;mi:u;illy by providing non-pumr.un/rd uniPb'iKlrd oprin'icn iitul Ituuupb (iormnciitcd fuel !mv i ng! m TOWOLDMONOQ24611 The Therminol Family You find more design and engineering flexibility with Therminol than with any other heat transfer, media because of the wide range ot fluids in the Therminol family. The Therminol series of heat transfer fluids offer an operating range of 0" to 800F. Important for the future, as your processes change, you can pick a new Therminol fluid to match your new needs. Most Therminol fluids are interchange able in your liquid heating system. The charts on the next two pages detail the broad characteristics of the Therminol family of fluids. On both ships and barges Therminol proornpis ihc high costs of pressurized indirect heating Thcrminol's ability to recover waste heat adds to the savings. Low temperature pumpability allows convenient cold weather start up, so viscou:-, liquid cargoes are ready for unloading where the vessel reaches pori 0173981 TOWOLDMONOQ24612 Temperature Use Ranges For Therminol Heat Transfer Fluids Thorminol heat transfer fluids offer a wide range of operating temperature capa bility. As this bar chart indicates, there is a Therminol fluid for virtually any spe cial temperature situation your process may encounter -- from 0 to 800:'F. Each Therminol fluid is carefully formulated to bring the best heat transfer prop erties to a given temperature situation. This page and the followingwill help you select the right Therminol fluid for your application. VJ TOWOLDMONOQ24613 f- ,1' : L 1" * ' * 'i* (>' ` * THERMINOL 55 ' Temperature F *c PAmVrberasnsposHoluuorrt.e* .... ( BSTpHUee.e/aHLtbta.T 4 ' BTCUoT/nHhdreu.rfmctt*iavcliFty/ft 0 -18 . . 0.420 0.0813 100 38 , , 0.5 ` 0.472 ' ' 0.0784 200 93 , 3.0 0.522 0.0753 300 149 400 204 10 40 00..567220 >1 0.0724 0.0692 500 260 100,,, , 0.670 . 0.0661 600 316 250 ' V 0.718. ;; ' 0.0630 ' LObo./nGsiatyl. . 7.62 ' 7.31 7,00 6.69 . 6.39 8.07 5.76 ViscCossity 1610 30 _ 2.1 1.18 0.80 0.60 T~r THERMINOL 66 FTemperatureC PAmrVbemsasopsHlouugrrt.ee BTSUpHe.e/cLaibfti.c'F BTCUoT/nHhderu.rmcftt1aivliFty/ft. LDbe.n/Gsiatyl. ViscCossity t 0 __ 50 10 100 38 _____ 0.320 0.350 0.380 0.0720 0.0711 0.0703 6.67 50000 8.51 250 8.34 28.0 ! 150 66 200 93 __ 0.1 , 0.405 0.430 : 0.0695 0.0687 8.14 7.91 10.0 4.40 > 250 121 300 350 149 2.0 177 ' .-- 400 204 20.0 0.455 0.480 0.505 0.530 ` . 0.0678 0.0670 0.0662 0.0653 7.77 7.59 7.39 7.17 2.60 1.70 1.20 0.90 450 232 500 260 550 288 50.0 100.0 200.0 0.555 0.580 0.605 0.0645 0.0637 0.0628 7.04 6.75 6.62 0.69 0.55 0.46 600 316 350.0 0.630 0.0620 6.42 0.40 650 343 760.0 0.655- 0.0613 6.24 0.36 700 371 1000 0.680 0.0605 6.09 0.31 tax THERMINOL 88 : 1 r ^Temperature F *c PmVremaspsHougrr.e BSTpHUee/ca#ifticF BTCUoT/nhhdre-urfmct't-aivlFity/ft. LDbe.n/Gsiatyl. Viscocssity 300 149 1.2 0.467 0.0738 8.41 1.57 400 204 ii 0.497 0.0712 8.00 0.87 500 260 65 0.525 0.0686 7.66 0.55 | 600 316 260 0.554 0.0660 7.33 0.38 t 700 371 800 0.584 0.0634 6.91 0.29 800 426 1500 0.613 0.0608 6*58 0.23 900 482 3000 0.642 0.0581 6.16 0.19 n\.73`>tt3 TOWOLDMONOQ24614 Applications Unlimited The pictures on the preceding pages have given you a glimpse of a few typical Therminol applications. On land and sea. In plants and apartment buildings. But the applications for Therminol are actually unlimited. As unlimited as your needs for safe, uniform, efficient heat delivery. Here are a few more areas where Therminol has met those needs: CHEMICAL PROCESSING . . . especially where flammable materials are handled. Therminol has proved particularly success ful for exchangers, distillation columns, reboilers, mixers, dryers, etc. RESIN PROCESSING . . . where a single "circuit" with multiple users and varying temperatures is desirable. PLASTICS, RUBBER MOLDING AND PAPER . . . where uniform heating, rapid temperature flux and pin-point control is essential such as heating corrugating and drying rolls, crimping presses, calendars, platens and molds. TEXTILES PROCESSING ... for con trolled temperatures in processing and finishing of synthetic fibers. PETROLEUM AND OH'-SIr> r.! : 1 ING . . .offers control over a wide tem perature range and the ability to accom modate sudden fluctuations in processing loads automated with complete safety. SHIPS AND BARGES . . . preempts the cost of pressurized indirect heating sys tems with efficient, dependable heating while underway. SPACE HEATING . . . ideal for hospitals, hotels, apartment houses and office build ings where the goal is safety, low main tenance and reduced operating costs. 017396* TOWOLDMONOQ24615 You Don't Have To Be An Expert We'll loan you ours. Talk to the Monsanto heat transfer ex perts. They've provided consultation for hundreds of Therminol fluid sys tems--in both new installations and in conversions of existing systems. They can point ouf the benefits of a Ther minol system, and offer detailed as sistance to you now-- no matter what stage your project is in, what applica tion you have in mind. From design and engineering to start up opera tions, you'll be surprised at how easy it is to work with a Therminol heat transfer system. TOWOLDMONOQ24616 DISTRICT SALES OFFICES ALLDIVISIONS | Additional District Offices an maintained by: AKRON, OHIO 44313 260 Springside Drive Montrose Development Park Tel. (216) 666-4111 ATLANTA. GEORGIA 30339 320 Interstate North Parkway Suite 500 Tel. (404) 432-7111 BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617) 387-5010 CHICAGO, ILLINOIS 3158 Des Plaines Ave. Des Plaines, Illinois 60018 Tel. (312) 296-6688 CINCINNATI, OHIO 45206 1501 Madison Road Tel. (513) 751-6707 DETROIT, MICHIGAN 500 Northland Towers West Southfield. Mich. 48075 Tel. (313) 357-0910 HONOLULU, HAWAII 96812 205 Pacific International Bldg. 677 Ala Moana Blvd., P. O. Box 3824 Tel. (808) 531-2744 HOUSTON. TEXAS 77027 1301 Post Oak Tower 5051 Westheimer Road Tel. (713) 621-9550 . LOS ANGELES, CALIFORNIA 90022 6670 E. Flotilla St. Tel. (213) 723-2492 J Agricultural Division DECATUR, ILLINOIS 62523 J 207 Decatur Professional Building 363 South Main Street Tel. (217) 423-6031 DES MOINES, IOWA 60310 J 312 Merle Hay Tower Tel. (616) 276-8603 J INDIANAPOLIS INDIANA 46206 Suite 215, 4002 Meadows Drive Building * Tel. (317) 647-9148 KANSAS CITY, MISSOURI 64133 l 701 Blue Ridge Tower 4240 Blue Ridge Boulevard J Tel. (816) 353-8060 LULING, LOUISIANA 70070 P. O. Box 174 Tel. (504) 784-6263 MANKATO, MINNESOTA 66001 111 Madison East Tel. (607) 387-3406 MEMPHIS, TENNESSEE 38104 303 Union Plaza Building 1835 Union Avenue Tel, (901) 278-7811 J MUSCATINE, IOWA 62761 P. 0. Box 473 Tel. (319) 263-1331 Hydrocarbons & Polymers Division NEW ENGLAND AREA 730 Worcester St. Indian Orchard, Mass. 01051 Tel. (413) 788-6911 Lion Oil EL DORADO, ARKANSAS 71730 Lion Oil Building Tel. (601) 863-3111 JACKSON. MISSISSIPPI 39209 P. O. Box 10937, Westland Station Tel. (601) 362-3648 J N. LITTLE ROCK, ARKANSAS 72119 410 West 8th Street, P. O. Box 6821 ! Tel. (601) 376-2437 MEMPHIS, TENNESSEE 38113 1023 Riverside Drive, P. 0. Box 13248 Tel. (901) 948-4451 f , i < r S , i : ' : NEW YORK, NEW YORK 10017 277 Park Avenue Tel. (212) 922-4111 ST. LOUIS, MISSOURI 63166 800 N. Lindbergh Blvd. Tel. (314) 694-1000 SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara, Calif. 95052 Tel. (408) 243-0414 SEATTLE, WASHINGTON 98121 2112 Third Avenue Tel. (206) 622-4203 WILMINGTON, DELAWARE 19810 Sdlte 204, Bancroft Bldg. 3411 SHverside Road Tel. (302) 478-4600 Plastic Products & Rosins Division EUGENE, OREGON 97402 l 865 Seneca Road Tel. (603) 342-7201 2 KENILWORTH, NEW JERSEY 07033 North Seventh St. & Monroe Ave. J Tel. (201) 276-2900 NEW ENGLAND AREA 190 Grochmal Avenue Indian Orchard, Mass. 01051 Tel. (413) 788-6911 Taxtilts Division CHARLOTTE, NORTH CAROLINA 28210 6230 Fairview Road, Suite 400 l Tel. (704) 364-0110 GREENVILLE, SOUTH CAROLINA 29606 ! McAlister Plaza P. O. Box 5564, Station B Tel. (803) 242-6700 * NEW YORK, NEW YORK 10001 l 350 Fifth Ave. Tel. (212) 556-5100 ,10 ' j j ; ! ' , 1 { : , " MONSANTO, 800 N. LINDBERGH BLVD., ST. LOUIS, MISSOURI 63100 \ J8/71 "Nothing contained herein is to be construed as a recom mendation to use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES^S TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCTS REFERRED TO. no guarantee of satisfactory results from reliance upon con tained Information or recommendations, and disclaims all liability for any resulting loss or damage." TOWOLDMONOQ24617 0173987 Monsanto Monsanto Industrial Chemical Company / Specialty Products / 800 North Lindbergh Blvd. / St. Louis. Missouri 63166 TOWOLDMONOQ24618