Document Newokga0R58LavQLvYo75yybw

AMERICAN STANDARD KEWANEE cmijiprMrjT BOILER UNITS W^tSf:tyPe a truly versatile ' W!mpy unit s M-&*- Kewanee's famous "Square-Heat" boilers for heating and low pressure process applications have earned the respect of architects, engineers, contractors and owners everywhere in every conceivable type of installation--industrial buildings, offices, schools, motels, churches, stores and institutions. Compact--yet effective three pass, wet back, firebox design offers generous amounts of heating surface and combustion volume . . . economical operation with minimum attention and care. The "Square-Heat" Boiler Unit features gas-tight construction and is furnished complete with refractory filled, skidtype base; steam or water trim; insulated, enameled steel jacket. All components are assembled and shipped as a single unit for field mounting of fuel burning equipment of your choice. The Kewanee Square-Heat Boiler Unit is ideally adaptable to a wide range of burners... gas or oil, forced or mechan ical draft. The unit will easily operate at and maintain 80% efficiency when fired at recommended rates, and will carry peak loads without wear or strain and constant burner adjustment.. . with real fuel saving economy. MORE "ALL-AROUND" QUALITY FEATURES THREE PASS DESIGN Efficient three pass design provides maximum heat transfer with low stack tempera ture . . . highest operating efficiency. Large firebox with arched upright crown sheet allows thorough mixing of fuel and air... complete combustion before hot gases enter fire tubes. The second pass is rear to front through direct fire tubes... the third from front to rear in return tubes. Gas travel is longer and there are no refractory baffles to burn out causing the short circuiting of gases. 1. COMPLETELY ASSEMBLED--bate and refrac- steeljacMtwiftiattractive.snioothonaniellinish. ,, _ tpiy. insulated Jaclwt,tr^0f;4tpmor ; , Grass of mineral fiber Insulation rninimizes heat ijimprotelyaerableJaifid(rtl(iil(4edDiitlieuniL . L :;Vr Only burner mounting pldte, burner and requited - , - Wdc cont^Uoos^fnnnededta put.th* writtu. operation, ' : v' . V". ^ Spjp^lTSEU.tCTfOltf^ . ptate. All diBlded constiui:tiDn fi)r strength and durability. Gas tight throughout. 2. WATER HEATtNC COILS-slandard Kewanee able for jll tmiti.' Cirll ojiening at front of boiler Wlfl* .tmrflrtti; wiring nr B. HIGH EFFICIENCY HEATING SURFACE-the ' ratio of off^Vb jniqiery heafing surface (ex-: posed directlyto theflamejto secondary Heating io%surface (exposed to hot gases) is nearly i greater than fii niariy eompefitive units. 3. AMPLE STU* SPACE AND WATER CON t'lwifer 'enntoi^'ldiS'.Sfendy^afe'r .. line and a pleotifulreserve ot dry stearp. *. LARGE FURNACE VOLUNE-lor complete ' mioimfinhg; ... unrestricted gas flow... quiet operation. 4. TUBES ROLLER EXPAHDED-all tubfes are . securedto tubesheets b> roller expaniler... nonel ,VA CKS; TO TUBE.S-steell tlue .access ^'K IW |MrK:e provides qurch access to Hues without disturbing . fuel burning equipment. .; c -BrfMstflATED STEEL JACKET-heavy gauge. 10. SKID TYPE RASE, REFRACTORY FILLED-- provides ventilation under the unit and distrib- ; utes weight evenly. Floor of The combustion chamber is poured, insulating-type refractory, installed at the factory for durability and low maintenance cost. ASME Boiler Construction Code requirements have been followed in every detail... and the Kewanee name assures design and performance beyond any code requirements: 1. COMPLETELY ASSEMBLED 2. WATER HEATING COILS 3. AMBLE STEAM SPACE ANO WATER CONTENT d. TOBESROLLEfl EXPANDED 5. EASY ACCESS TO TUBES A INSULATED, steel Jacket 7. GAS TIGHT , CONSTRUCTION 8. HIGH EFFICIENCY HEATING SURFACE 9 URGE FURNACE VOLUME 10. SKID TYPE BASE 28520 toy:American-Standard, Inc. '" / Since product improvement is a continuing effort at American-Standard, the right is reserved to make reasonable changes of any kind without notice. -HH a;. a; -^eH %%;%%cVV%Si;%:t. Ill KEWANEE SQUARE-HEAT BOILER UNITS Ratings and Data---forced-draft-- Oil, gas f-s ' >%& v UNIT NUMBER 1 3R1-F ! 3R2-F 3R3-F 3R4-F | 3R5-F 3R6-F 3R7-F 3R8-F 3R9-F 3R10-F 3R11-F| 3R12-F SBI gross output horsepower steam per hour 212F. steam SBI net rating--steam MBh. lbs. sq. ft. sq. ft. 324 10 334 1350 1010 | 396 ! 12 1 408 1650 '1240 ! 468 14 482 1950 11460 540 16 557 2250 1690 648 19 i 668 12700 12020 792 24 816 3300 2480 1 936 1 28 ! 965 3900 12930 1080 32 1113 4500 3380 1260 38 1299 5250 3940 1440 43 1484 6000 4500 1620 48 1670 6750 5060 i 1800 1 54 1855 17500 5620 Firing rate--gas 1000 Btu/cu. ft. oil 140,000 Btu/gal. 405 | 495 : 585 675 ' 810 990 |1170 1350 1575 1800 2025 2250 2.9 ! 3.5 4.2 4.8 5.8 7.1 . 8.4 9.6 11.2 12.9 14.5 16.1 Fleating surface--Total primary sq. ft. sq. ft. Furnace vol. net cu. ft. Safety valve capacity steam per hour lbs. Approximate dry weight lbs. 53 65 77 20.5 . 22.8 25.2 7.8 . 9.1 ! 10.5 424 520 . 616 1650 ; 1800 11950 88 i 106 27.5 j 33.0 11.7 ! 15.4 704 848 2100 12350 129 ' 153 36.6 1 40.4 17.9 20.4 1032 1224 2700 13000 177 44.5 23.3 1416 3300 206 49.5 29.5 1648 3700 236 54.1 33.4 1888 4150 265 294 58.4 62.6 37.1 40.8 2120 2352 4500 14900 . Vent diameter--forced draft Stack diameter--natural draft Stack height--natural draft in. 6 6 6 6 8 8 1 8 8 10 10 10 ' 10 in. 12 12 12 12 15 15 15 15 18 18 18 18 40ft. 30 , 35 i 35 ,_iL_ ! 35 40 i 40 45 35 45 ! 50 Dimensions (Inches) A -- Boiler length A, --Overall length 301/2 46 V? 361/2 52`/> 42 y? ' 48 y? 58% 64'/2 A2 --Overall length including tube removal B --Overall width C --Overall height Cj --Shell height D -- Boiler centerline to greatest width E -- Rear smokebox depth --Standard rear outlet ' --Top outlet forced draft --Top outlet natural draft -- Front smokebox 70 37% : 59 55 211/2 8 8>/2 12/2 8 82 371/2 59 55 21 y? j 8 81/2 ; 12 V? : 8 94 , 106 37`/2 37'/. 59`/2 . 59`/ 55 ; 55 1 211/2! 8 8/2 : 12`/? : 8 21'/2 ! 1 8. 81/2 ; 121/2 8 J Boiler shell width K, -- Firebox length K? Width ...K3 Height L --Smoke outlet diameter--forced draft -- natural draft N -- Smoke outlet height--rear outlet --top outlet 28 % 25 V2 24 18/2 6 12 36 42% 28'/2 311/2 24 18/2 6 12 36 42/4 28% 371/2 . 24 18'/2 6 12 36 421/4 281/2 431/2 24 I81/2 6 12 36 421/4 i P -- Supply size 0 --Supply location R -- Supply height S -- Return location -- Return size V -- Safety valve location w -- Normal waterline Y --Coil connection height AA -- Base length BB -- Base width HH --Tube removal space 4 10 56 7 3 8 46 47 33`A 32 v? 31/2 4 12 56 7 3 8 46 47 39% 32% 37% 4 14 56 7 3 8 46 47 45/2 321-? 431/2 , 4 16 56 7 3 8 46 47 511/ 32'-.? 491/2; Addforihcreasedlength if top smoke outlet h> used, See dimension E. **150 lb. American Standard flange--eight 34 in. bolts- 9l/2 in. bolt circle. 421/2 501/2 : 58 67 56y? 641/2 59`/2 671/2 75 84 75`/2 831/2 94 | 110 : 125 42 i 42 42 67 ' 67 ! 67 62 I 62 ; 62 143 123 139 42 ? 49 i 49 67 761/2 1 76/2 62 1 71 : 71 231/2 231/2! 231/2 8 10y2 141/, 9 8 10 V? 141/2 9 8 101/2 14/2 9 23'/2! i 8; ioy2 141/2 9 27 1 9 121/2 , 161/2! 10 27 9 121/2 I61/2 10 321/2 , 371/2 28 : 23 32/2 45 28 23 32/2 53 28 23 321/2 62 28 23 391/2 51 . 35 ; 28 . 391/2 59 35 28 8 15 41 491/4 8 15 41 491/4 8 15 41 491/4 8, 15 , 41 491/4 1 10 1 18 471/2; 571/21 10 18 471/2 57'/2 4 4 4 4 6** 6** 14 17 19 22 16 18 63 63 63 63 : 75'/. 751/2 71/2 7 '/> 71/2 TV?. IVi TV? 4 4 4 4. 4 4 8 10 10 10 : 12 12 53 53 53 61 61 61 54 54 54 54 62 62 451/2 37 53 `/2 37 61V? 37 70 37 59 y? 44 67 V? 44 431/? 51 %2 59 68 571/2. 65 % 72 91 154 49 76y? 71 27 9 121/2 16y2 10 391/2 661/2 35 28 10 18 47`/2 57'/2 20 751/2 71/2 4 12 61 62 75 44 73 28521 79y? --I-5 98!/2 . . 169 49 76'/2 71 27 %%, 9 121/? 16 y? /"Tiy/* 10 391/2 /TV-. 74 . 35 28 10 18 47'/ 57% // , - 6** 24 75% - IV? 4* H 12 61 62 82% 44 80% STANDARD AND OPTIONAL EQUIPMENT standard equipment optional equipment ALL UNITS 1 Three-pass ASME Code Boiler 2. Refractory Filled Skid Type Base 3. Gas-Tight, insulated f-'ront Smokebox 4. Rear Pyrex Observation Port 5. 3" Firetubes--Roller Expanded --with Spinner Blades in Direct Tubes 6. Gas-Tight Rear Smokebox with Rear Vent for Forced Draft Firing 7. Wrap-around Insulated Steel Jacket 8. Washout Plug Socket Wrench 9. Flue Cleaner with Handle 10. Listed Standard and Selected Optional Equipment --assembled and mounted, ready for burner installation and connection to water and steam. (Exceptions: Items shipped separately to prevent shipping damage.) 1. Relief Door 2. Top Vent 3. Operating Limit Control 4. Safety Limit Control 5. Control Wiring Harness 6. Instantaneous or Tank Type Hot Water Coils 7. Flue Gas Temperature Gauge 8. Burner Mounting Plate--adaptable to most burners. Blank plate with retaining ring for refractory to fit boiler opening. 9. Factory Burner Mounting 1. No 767 Low Water Cut-off 2. Safety Valve 3. Compound Steam and Vacuum Gauge 4. Water Gauge and Glass STEAM UNITS 1. Combination Low Water Cut-Off and Pump Control 2. Combination Water Feeder, Low Water Cut-off and Alarm Switch 3. Second Low water Cut-off 4. Surface Blow-off 1. No. 764 Low Water Cut-off 2. Relief Valve 3. Combination Altitude Gauge and Thermometer HOT WATER UNITS 1. Combination Water Feeder, Low Water Cut-off and Alarm Switch AMERICAN STANDARD HLAT TRANSFER PRODUC I'S DEPARTMENT DETROIT. MICH 4H2U Bulletin No. 92-6-92C 20M 8-67 JM Unit 3R1- 4F 3R5- 8F 3R9-12F a 11 12 V; 13'/2 CONTACT YOUR NEAREST KEWANEE SALES OFFICE- b 20`A 25 30!/2 28522 Lit ho in U S. A