Document NeoZY8mLGYD27jyqbrMjDjMzp

Air Conditioning, Automatic Healing Systems Gar Wood Industries, Inc. OafO/oaf AIR CONDITIONING DIVISION 7924 Riopelle St., Detroit, Mich. Licensed Distributors in All Principal Cities TEMPERED-AIRE UNIT The Tempered-Aire heating and air-conditioning equipment made in six (6) capacities, consists of filters, blower, burner, humidifier, and oil furnace engineered into one compact, coordinated system. Clean, humidified, warmed air is delivered from the unit to the duct system and then uniformly distributed to all parts of the building. Air is cleaned by dry cloth filters and circulated by a multiple-blade blower fan. The heating unit is a down-draft, warm-air furnace equip ped with an integral pressure atomizing type oil burner. The humidifier is a steam tube within the firebox, assuring simple and prompt humidification. The new line of Tempered-Aire units (Models 101, 201, 301) have many improve ments including the new Model "O" oil burner and new cabinet design (see cut opposite). The oil burner starts, operates and cuts off smoothly even with widely varying draft con ditions. Combustion is clean, quiet and ef ficient, due to the improved manner in which the air and oil are mixed to make a sunburst shaped flame. CO? is exceptionally high, and even greater economy than previous models is assured. Tempered-Aire Ratings and Dimensions Btu 1 Hour at Bonnet........................................... Btu 1 Hour at Grilles......... ................................... Air Delivery CFM................................................. Air Temperature at Bonnet............................. Oil Rate. Gallons 1 Hour....................................... Heating Surface. Sq Ft.......................................... Filter Area. SqFt.................................................. Motor Horse Power-Burner................................... Motor Horse Power-Blower................................... Over all Length. Inches......................................... Over all Width. Inches........................................... Over all Height. Inches.......................................... No. 101 100.000 60,000 . 1,000 160 1.00 54% 30 1/6 1/5 77% 32 54 No. 201 135.000 110.000 1350 160 135 64 30 *i/5 82% 32 54 No. 301 200.000 160.000 2.000 160 2.00 86% 40 1/6 1/3 9214 32 54 No. 104 225.000 185.000 2.250 160 2.25 176 60 1/6 1/2 140% 38 64 No. 105 300.000 245.000 3.000 160 3.00 220 77 1/6 3/4 156% 38 64 No. 105-C 400.000 4.000 160 4.00 220 77 1/4 156% 38 64 GAS FIRED TEMPERED-AIRE Built in a single unit, it provides air filtering, blower circulation, humidifying and heating. Furnace is made, of heavy gauge copper bearing steel. Thermostatically operated. Safety con No. 90 No. 120 trols give full protec tion. Ap proved by Amer. Gas Assoc. AGA Input, Btu per hour............ AGA Output, Btu per hour......... Grille Delivery Btu per hour....... Air Delivery CFM............... Filter Surface Sq Ft.............. Blower Motor Size........................ Blower Motor Current Consump. Overall Length. Inches................. Overall Width, Inches.................. 135.000 101,250 90.000 900-1425 34 1/5 hp 250 Watu 96% 40 160,000 135.000 120.000 1200-1900 34 1/5hp 250 Watu 96% 40 906 Car Wood Industries, Inc. Air Conditioning, Automatic Healing Systems MODEL "R" BOILER-BURNER UNIT A compact firetube steam or hot water heating boiler, with an integral oil burner. Boiler built of heavy rust-resisting boiler plate, electrically welded. The combustion chamber walls are carried clear to the crown sheet. The result is a considerably higher temperature of fire than is found in the conventional boiler, and better com bustion of No. 3 oil. Since there are no water legs, the bulk of the heating surface is concentrated in the firetubes, or secondary heating surface, resulting in maximum extraction of heat from the hot gas which leaves the firebox and consequent low stack temperature, high efficiency and operating economy. Burner Model Firing Rate--Gal per Hour . -............................... Mifmirn Net Steam Load--Sa Ft...................... Maximum Net Hot Water Load--Sq ht.............. Maximum Gross Steam Load--Sq fr t................... Maximum Gross Hot Water Load--Sq Ft........... Heating Surface--SqFt.......................................... Overall width--Jacket........................................... Overall Length--Jacket..'..................................... R500 H 1.65 500 800 750 1200 52 30% 53 R750 H 2.50 750 1200 1125 1800 68 30% 65 R1000 D 3.25 1000 1600 1500 2400 84 37% 59V, R1400 D 4.50 1400 2240 2100 3360 II8 37*% 66 . RI800 D 6.00 1800 2880 2700 4320 154 37% 60 VENTILATOR A silent op erating venti lator--attic or commercial use. Ventilator consists of beltdriven propel ler type fan; electric motor with overload protection; metal hous ing; automatic shutter; insect screen; canvas connection and clamps; suspension springs. 8 Sizes: 20 in. to 60 in. CFM: 3500 to 30,000. INDIRECT AIR CONDITIONING EQUIPMENT Made in eight (8) sizes. Consists of a compact cabinet unit containing cloth air filter and vapor mist filter, blower, hu midifying chamber, and indirect, blast heater. While designed par ticularly for use with Gar Wood Boiler-Burner Units (steam, vapor, or hot water), the air con ditioning unit may be used effectively with any adequate existing plant. OIL-FIRED WATER HEATERS Commercial Type--An attractive, quiet operating balanced unit, in 2 sizes. Burns No. 3 fueloil. Fully auto matic. Separate tank.Capacities: 200 and 300 gal per hour 100 F tem perature rise. Over all widths: 28% in.; lengths:49in.-6lin. Domestic Types--Model S50 --coil type heater for use with separate storage tank. Cap. 50 gal per hour 100 F temperature rise. Model S40 has storage tank integral. Cap. 40 gal per hour 100 F tem- perature rise. Both || d T types have vertical j. rotary burner with jV| only one moving Egjgggafl part and for use with No. 2 or lighter oil. Model Sso Model S40 Highly efficient for installation in- existing heating plants. Pres sure atomizing type. Simple in design. Han dle No. 3 fuel oil. Sturdy, quiet, easily accessible. Fit any shape of firebox. CONVERSION OIL BURNERS Model " W** 41-500 sq ft net steam radiation. Model "K" 41-600 sq ft net steam radiation. Model "H" Up to 66 sq ft net steam radiation.