Document NeZvbzNKQoVaw2jygB7bR60g8

3. For tie rod and concrete from plane D to plane E the conductance Ci is _ 0.00048 400 0.99952 12 ,,,,oc Ci = ~io-><r5+-rr><r5 =0192 +11994 -12186 i Series Flow. After the conductance values have been determined, the total re sistance and U value can be determined as follows: 1 ii 1 .I+I+5+1- C,C,k,f. ______ 1_ 3f) 1 1 1 ___ " 1.65 + 12.0 + 12.186 + 0.197 + 12.186 "r 12.0 ^ 6.0 Rt = 0.606 + 0.250 + 0.0821 + 5.076 + 0.0821 4- 0.250 + 0.167 = 6.513 U = = -j-- = 0.153 Btu per (hr) (sq ft) (F deg). Rt 6.513 The Hot Box test value, from University of Minnesota, for this wall,'? corrected for a 15 mph wind velocity, was U = 0.150 Btu per (hr) (sq ft)? (F deg). The error between the calculated and test values would be ?! 0.153 - 0.150 ^ X 100 *= 2 percent. ? If the effect of the tie rods were omitted from the calculations, the over-:-, all U value would be 0.103. Although the percentage of area occupied by.? 0.00048 .. _ _o _cent| the tie rods per square foot of wall area is X 100 = 0.048 perc the error between the calculated and test values would be 0.150 - 0.103 x 100 = 3i percent. $ I In making the calculations for values of U shown in Tables 7 to 19, thej: following conditions have been assumed: vf- Equilibrium or steady-state heat transfer, eliminating effects of heat capacity. , Surrounding surfaces at ambient air temperatures. i.r Exterior wind velocity of 15 mph. Surface emissivity of ordinary building materials = 0.83. \ No correction for position or direction of heat flow. (Average coefficients used)-,r Air spaces are I in. or more in width. Variation of conductivity with mean temperature neglected. Corrections for framing made on basis of parallel heat flow through 2 X 4 in. ( nal) studs, 16 in. on centers, the framing covering 15 percent of wall area. Heat Transmission Coefficients of Building Materials 183 Actual thicknesses of lumber assumed to be as follows: Nominal Actual 1 in. (S-2-S)............... ............... H in. H in- (S-2-S)............... ............... It* in. 2 in. (S-2-IS)............... ...It in. 2\ in. (S-2-S)............... ............... 2| in. Nominal Actual 3 in. fS-2-S)...................................... 2| in. 4 in. (S-2-S)...................................... 3f jn. Finish flooring, (maple or oak) . . .1J| in. Coefficients for frame construction are corrected for the effect of framing where such correction would increase the coefficients, but not where the correction would decrease the coefficients.10 It should be noted that the effects of poor workmanship in construction and installation have an increasingly greater percentage effect on heat transmission as the coefficient becomes numerically smaller. Failure to meet design estimates may be caused by lack of proper attention to exact compliance with specifications. A factor of safety may be employed as a precaution when it is judged desirable. Some engineers do not use a 17value less than 0.10. Roof Coefficients Computations for wood shingle roofs applied over wood stripping are based on 1 by 4 in. wood strips, spaced 2 in. apart. Values for roofs con taining Spanish and French clay roofing tile are assumed the same as for slate roofs. Values for pitched roofs in Table 17 apply where the roof is over a heated attic or top floor, so that the heat passes directly through the roof structure, including any interior finish material. Combined Ceiling and Roof Coefficients If the attic space between the ceiling and roof is unheated and not venti lated, the combined coefficient from room air below the ceiling to exterior air can be calculated from the following formula: ^ Uc+nUr and (4) vhere V = 1/Rt V = combined coefficient to be used with ceiling area. A ij = total resistance of eeiiing and roof. u,, u, -- = coefficient coefficient of of transmission transmission of of ceiling. roof. n = ratio of roof area to ceiling area. (5) It should be noted that the overall coefficient U should be multiplied by the ceiling area to determine heat loss, and not by the roof area. Values f U, and U,,, should be calculated using a value of 2.2 (the reciprocal of one-half the air space resistance) rather than 1.65 for the conductances of surfaces facing the attic, since the attic is equivalent to an air space. the attic contains windows, dormers and vertical wall spaces, and if their area is small compared to that of the roof, they may be considered part of the roof area. For accuracy, the sum of the coefficients of each ^dividual section, multiplied by its percentage of the total area, should be usea as UT. Where attic wall areas are large, it is preferable to estimate the temperature as illustrated in Chapter 12, and calculate the heat loss