Document NeQ5Mxxd0pR69j1a1NEY5rNe8
FILE NAME: Asbestos in Hair Dryers (HD)
DATE: 1978 DOC#: HD011
DOCUMENT DESCRIPTION: Report to CPSC - Review of NIOSH Testing of 30 Hand Held and Standing Hair Dryers for Asbestos Release
Review of NIOSH Testing of 30 Hand Held and Standing Hair Dryers
for Asbestos Release
Report to CPSC Contract # CPSC-C-78-0109
William J. Nicholson, Fh. D. Mount Sinai School of Medicine
ENVIRONMENTAL SCIENCES LABORATORY
m o u n t S in ai S C H O O L Of MEDICINE O f THE C l T v u n i v EKSITV O* NEW y o u
COCI GI00001
introduction This report is in response to a request by the Consumer Froduct Safety Commission (.CPSC) to revisv the National Institute for Occupational Safety and Health (NIOSH) study of asbestos emissions from various hand held and standing hair dryers. The reviev includes a discussion of the sampling and analytical techniques utilized by NIOSH, a comparison of results obtained by NIOSH vith other environmental asbestos measurements, and, in an appendix, a discussion of possible health consequences from asbestos concentrations that are found in the effluent of some hair dryers.
Sampling and Analytical Techniques The procedures developed to sample the effluent air from hair dryers are, by far, the best utilized in any available report to date. Care is taken to assure that clean air, uncontaminated by asbestos fibers, enters the dryer and a good determination is made of total dryer effluent and the fraction collected for analysis. While isokinetic sampling was not utilized, this would be difficult to achieve under the circumstances of testing high velocity air streams from a variety of dryers. The absence of isokinetic conditions may result in an underestimate (as the air velocity through the sampling head exceeded the duct air velocity), but this would be a relatively small effect. A greater underestimate of fiber release from the dryers may occur from the analytical procedures used to quantitate the number and mass of asbestos fibers released. Firstly, collection of fibers on Millipore filters and the subsequent dissolution of the filters by a Jaffe wick method can lead to significant fiber loss (perhaps up to 80Z) unless extreme care is taken.
.
C0 02
GI00002
percent of the effluents measured were typical of the ambient air. However, without further data it is not possible to determine if this is an attribute of the model tested or the particular dryer tested (in its current state of use). Special concern must be paid to standing dryers because of the possibility of their nearly continuous use, often in confined spaces, in hair salons. Here a build up of asbestos concentrations in excess of that in dryer effluents can occur.
SUMMARY
Using analytical techniques which may underestimate the concentration of asbestos, NIOSH has clearly demonstrated that some hair dryers release considerable quantities of asbestos fiber. The fiber concentrations in the effluent of some dryers exceeded the highest we have measured in eight years of surveillance of environmental asbestos contamination. Appendix 1 discusses the possible health risks of such concentrations. u m ift the risk to an individual from the intermittent use of an asbestos emitting hair dryer is less than that from many current occupational asbestos exposures, the large number of individuals that may be exposed clearly calls for the elimination of the exposure.
e 003
GI00003
Appendix 1 ENVIRONMENTAL ASBESTOS CONTAMINATION
AND HUMAN HEALTH EFFECTS
Report to CFSC Contract # CPSC-C-78-0109
William J. Nicholson, Fh. D. Mount Sinai School of Medicine
CO 04
GI00004
'
The contamination from spray sites was extensive, with asbestos debris
o i covering the sidewalks and streets adjacent to the building. Attempts
were made on some Job sites to contain the spray by tarpaulins, but these were
often torn, loosely secured, and ineffective as containment. It is difficult
to imagine contamination about a factory, even forty years ago, exceeding that
from the direct spraying of asbestos materials into a community from a building
40 or more stories high. The evaluation of building air was in schools in which
damage, sometimes extensive, had occurred to friable asbestos surfacing material
in hallways or cafeterias. In some schools, the students had reached up to the
ceiling and physically dislodged asbestos material. The household measurements
were made in the homes of workers employed in chrysotile mining operations in
California and Newfoundland. At the time
neither shower facilities nor
adequate change rooms were available to the workers.' Thus, the households
sar 'ed oecassionally had visible asbestos fibers in the living areas of the
house as well as dusty clothes awaiting cleaning in laundry facilities.
ANALYTICAL TECHNIQUES
In these measurements, the same analytical techniques have been utilized .
as were originally developed for the analysis of ambient air samples of chrysotile
asbestos.^ Thus, there is a direct comparability in the results of all analyses
reported here. All samples were collected on 0.8 pm pore size membrane filters
and analyzed using electron microscopic techniques that determined the amount
of chrysotile asbestos in each specimen. This variety of asbestos was quantitated
because it could easily'be identified on the basis of its unique tubular structure.
Amphibole asbestos (either amosite or crocidolite) could also be present in the
air of buildings or in the ambient air, but it is much less commonly found. However,
if sent in the air sampled, such asbestos would add to the concentrations reported
here.
.
G005
GI00005
A
' ^rs, higher values than those mentioned above were obtained.^ These were
six-to-eight hour samples collected between 8:00 A.M. and 5:00 P.M., and'
reflect what could be intermittently higher concentrations during those hours
compared to night time periods, for example. Table 2 records the chrysotile
content of 22 samples collected in the five boroughs of New York. It should
be noted that the samples analyzed in all of the studies discussed above were
taken during a period when fireproofing high rise buildings by spraying asbestos-
containing materials was permitted. The practice was especially common in
New York City. While no sampling station was known to be located adjacent to
an active construction site, unusually high levels could nevertheless have
from the procedure. Other sources that may have'.contributed to these
air concentrations include automobile braking, other construction activities,
consumer use of asbestos products and maintenance or repair activities of
asbestos-containing materials (thermal insulation, for example).
'
CHRYSOTILE ASBESTOS CONCENTRATIONS ABOUT CONSTRUCTION SITES
To determine if construction activities could Indeed be a significant
source of chrysotile fiber in the ambient air, six--to--eight hour daytime
sampling was conducted in lower Manhattan in 1969 about sites where extensive
spraying of asbestos-containing fireproofing material was taking place. 4,7
Eight sampling sites were established about the World Trade Center'construction
site during the period when asbestos materials were sprayed on the steelwork
of. the. first tower. Table 3 shows the results of those sites located within
one-half mile of the Trade Center site and demonstrated that spray fireproofing
can contribute significantly to asbestos air pollution. In some Instances,
cb atile asbestos levels approximately 100 times the concentrations typically
found in the ambient air were observed.
006
GI00006
6
CHRYSOTILE CONCENTRATIONS IN THE HOMES OF WORKERS
The finding of asbestos disease in family contacts of individuals occupa tionally exposed to the fiber directs attention to air concentrations in the homes of such workers. Thirteen samples have been collected in the homes of asbestos mine and mill employees and analyzed for chrysotile. The workers were employed at mine operations in California and Newfoundland and did not, at the time of sampling (1973 and 1976) have access to shower facilities nor commonly change clothes before going home. Table 5 lists the concentrations range of these samples. Three samples taken in homes of non-miners in Newfoundland yielded concentrations of 32, 45, and 65 ng/m^. In contrast, the workers homes were much higher, pointing to the need for appropriate shower and change facilities in asbestos workplaces. As asbestos cancers have been documented in family contacts of ww_.cers, concentrations such as seen here should be viewed with particular concern.
DISCUSSION
Three sets of data have been obtained demonstrating significant environ
mental contamination by asbestos in different circumstances. Seventeen samples
collected at various sites about the World Trade Center during the spraying of
asbestos materials on the steelwork for fireproofing purposes were analyzed for
chrysotile asbestos. Twenty-seven samples collected in public schools with
damaged asbestos surfaces and 13 in the homes of asbestos mine and mill
employees were also studied. In all cases the sampling was designed to reflect
the more serious instances of contamination in these circumstances. The severity
o ame of the conditions sampled was sufficiently great that it is difficult
to imagine conditions even in past years, more egregious than those considered here.
'
C007
GI00007
8
would primarily consist of deaths from mesothelioma and lung cancer.
Other data are in hand linking the incidence of lung cancer in workers
engaged in asbestos mining and milling and asbestos products manufacturing
to total dust concentrations in the workplace.
The best fit to these
data demonstrate a linear relationship between total dust and the rate of
excess mortality from bronchogenic carcinoma. Even though fiber concentrations
are unavailable in these studies, the linear relationship, with no evidence
of a threshold below which disease does not appear, suggests that any
extrapolation of the risk of asbestos disease in occupational circumstances
to environmental exposures should utilize a linear relationship. If 10% of
the deaths in workers exposed to 60,000 ng/m^ are asbestos related, such an
extrapolation suggests that 1/6000 deaths will be asbestos related,at daily-
environmental exposures of 100 ng/m^ and 1/600 at 1000 ng/m^. If the
exposures are intermittent, the risk would be correspondingly reduced.
While these risks are considerably less than those of occupational
circumstances, concern arises from the fact chat millions of people may
be exposed to multiple sources of lover concentrations through the daily
use of such products as asbestos insulated hair dryers, habitation of
public and private buildings containing asbestos-materials as fireproofing,
acoustic or thermal insulation, and in other environmental circumstances.
C008 GI00008
Table 2
Distribution of 4- to 8-hour daytime chrysotile asbestos concentrations in the
ambient air of New York City 1969 - 1970
Asbestos concentration (ng/m^) Less than
Number of samples
Percentage of samples
1
0
0.0
2
1
4.5
5
4
18.1
10
8
36.4
20
16
72.7
50
21
95.4
100
22
100.0
00C9
GI00009
Table 4
Distribution of chrysotile asbestos concentrations in 4- to 8-hour samples
talcen in public schools vith damaged asbestos surfaces
Asbestos concentration (ng/n3) Less than
Number of Percentage
samples
of samples
5 10 20 50 100 200 500 1000 2000
0
0.0
1
3.7
1
3.7
6
22.2
12
. 44.4
19
70.4
25
92.6
26
96.3
27
100.0
COiO GI00010
it r
References
1. Nicholson, W. J. Cancer following occupational exposure to asbestos
'
and vinyl chloride. 197?. Cancer 39:1792-1801.
2. Newhouse, M. and Thompson, H.. Mesothelioma of pleura and peritoneum following exposure to asbestos in the London area. Br. J. Ind. Med. 22:261-269.(1965)
3. Anderson, E. A. et al. Asbestosis among household contacts of asbestos factory workers. Ann. N. 7. Acad. Sei. In press. (1979)
4. Greenberg, M. and Davies, T.A. Mesothelioma Register 1967-68. Bt. J. of Ind. Med. 31_:91-104. 1974
5. Nicholson, W. J. and Pundsack, F. L. Asbestos in the environment.
Biological effects of Asbestos, Lyon, International Agency for
.
Research on Cancer, 126-130. (1973)
"
6. Nicholson, W. J. Measurement of asbestos in ambient air, Final Report, Contract CPA 70-92, National Air Pollution Control Administration (1971).
7. Nicholson, V. J. , Rohl, A. N. and Ferrand, E. F. Asbestos air pollution - :
in New York City. In Proceedings of the Second Clean Air Congress,
'
(eds.) England, H. M. and Barry, W. T. Academic Press, New York (1971)
8. Nicholson, W. J. et al. Contamination of U.S. Schools by asbestos surfacing materials. N. Y. Acad. Sei. In Press. (1979)
9. U.S. Environmental Protection. National emission standards for hazardous air pollutants. Federal Register 2113:8820 (April 6)
10. Peto, J. The hygiene standard for chrysotile asbestos. Lancet <l:484-489. (1978)
11. Committee on Hygiene Standards. Hygiene standards for chrysotile asbestos dust. British Occupational Hygiene Society. Ann. Occup. Hyg. 11:47-69
12. U. S. Environmental Protection Agency. Criteria for asbestos in water. (1979)
13. McDonald, J.C. Mortality in Canadian miners and millers exposed to chrysotile. Ann. N.Y. Acad. Sei. In press. 1979
14. Henderson, V. L. and Enterline, Philip. Asbestos exposure factors associated with excess cancer and respitatory disease mortality. .Ann. N. Y. Acad. Sei. In press. 1979
0011 GI00011
TESTING OF KAIR DRYERS FOR
ASBESTOS EMISSIONS
Charles L. Geriei, Jr., Fh.D. Paul A. Baron, Ph.D. Janes V. Carter Dav-id L. Smith \
Interagency Agreement NIOSH IA-79-29 with
U.S. Consumer Product Safety Commission
U. S. Department of Health, Education, and Welfare Public Health Service
Center for Disease Control National Institute for Occupational Safety and Health
Division of Physical Sciences and Engineering Cincinnati, Ohio September, 1979
G012
GI00012
t e s t i n g o f h a i r d r y e p .s FOR
ASBESTOS EMISSIONS
Charles L. Gerici, Jr, Ph.D. Paul A. Baron, Ph.D. Jaaes W . Career David L. Smith
\
Interagency Agreement NIOSH IA-79-- 29 with
.S. Consumer Product Safety Commission
D. S. D e partment of Health, Education, and Welfare Public Health Service
Center for Disease Control National Institute for Occupational Safety and Health
Division of Physical Sciences and Engineering Cincinnati, Ohio September, 1979
0012 GI00012
REPORT TO THE U.S. COMSUMER PRODUCT SAFETY COMMISSION ON TESTING OF HAIR DRYERS FOR ASBESTOS EMISSIONS BY
THE DIVISION OF PHYSICAL SCIENCES AND ENGINEERING NATIONAL INSTITUTE FOR OCCUPATIONAL SAFETY AND HEALTH
Background
Beginning in April 1979, the National Institute for Occupational Safety
and Health (NIOSH) furnished to the Consumer Product Safety Commission
'(CPSC) the laboratory and other support services necessary-to test the
effluent air of hand-held hair dryers for asbestos fibers. The need to
determine the possible release of asbestos fibers from h a n d-held hair
dryers containing asbestos insulation materials was realized by CPSC as a
result of news media disclosure of asbestos release and a petition by the
Environmental Defense Fund, Inc. (EDF). The petition presented by EDF
requested that CPSC proceed under the Consumer Product Safety Act to remove
hair dryers containing asbestos from the consumer marketplace. Preliminary
evidence was presented by EDF which allegedly demonstrated the ability of
several hair dryers containing asbestos insulation material to emit
asbestos fibers. To fully evaluate the potential consumer exposure tc
asbestos from asbestos containing hand-held hair dryers CPSC determined
that the identification and quantitation of fibers emitted by the dryers
having lengths and diameters of as little as 1 micrometer (um) or less
would be necessary. To accomplish this task any samples generated woulc
require analysis by a transmission electron microscope (TEH) capable of
performing energy dispersive analysis of x-rays (EDAX) and selected are*
electron diffraction (SAED). The actual sampling of effluent air from thi
hair
dryers
would
also require expertise and capabilities in the area of
C013
GI00013
air sampling and Che fabrication of controlled atmosphere test systems Both the sanpl-ing and analysis experience necessary to perforn a study o this type reside within the Division of Physical Sciences and Engineerin (DPSE) of NIOSH. On April 12, 1979, NIOSH and CPSC entered into a Interagency Agreement to accomplish the task of evaluating potentia consumer exposure to asbestos released by hair dryers.
Ob 1e c tive
The primary objective of the project was to quantitate and identif asbestos structures in the effluent air of hand-held hair dryers durin operation. Making this determination would require the following:
1. A count of asbestos structures and fibers sampled during operatio of the product.
2. Qualitative Identification by EDAX or SAED of fibers sampled a being asbestos or non-asbestos.
3. Determination of the size distribution of sampled asbestos fibe lengths and diameters.
A. D e t e rmination of fiber count and fiber mass per cubic meter o effluent air.
To meet the needs of the project a system to determine asbesto emissions from hair dryers was fabricated and validated by NIOSH. sampling of hair dryers, new and used, that contained asbestos wa collected by CPSC and submitted to IIIOSH for testing. All dryers wer
- 2-
.
.
0014
GI00014
tested as received from CPSC.
Test Syster.
The valid determination of asbestos release from the hair dryers
demanded the test system meet several reqairements Previous tests (1-4)
indicated that a valid determination of the amount of asbestos emitted by
various hair dryers would require a clean sampling system capable of
accurately determining asbestos concentrations over a vide range.
Therefore, the air entering the hair dryers in the test system was filtered
to eliminate the possibility of external asbestos contamination and to
reduce the amount of background particulate that m i g h t Interfere with the
electron microscope analysis of the samples. Th e high flovrate of air
through many of the dryers precluded complete collection of the effluent.'-
Therefore, the test system vas designed to obtain an accurate represent-
;tive sample of the hair dryer effluent.
The hair dryer test system consisted of several components Including a
clean air source, a sampling duct assembly, several types of monitoring
equipment and filter samplers. A schematic of the test system is shown in
Figure 1.
3 The high flovrate (up to 2 n /min) produced by some hair dryers
required a high flowrate, clean air source to eliminate background
Interferences during testing. A test tunnel in the NIOSH dust laboratory
was adapted for these tests. Two 60 cm x 60 cm high efficiency particulate
air (HEPA) filters in series were used to remove ambient particulate. The
ducting around the high flowrate blower was
sealed
to prevent
-3-
0015
GI00015
.ricontanmation ^ of the air introduced into the specially constructed clear air test chamber (volume*' 1 m^). The airstream entering the test
chanber was deflected by a netal plate and diffused through a punched-hol< screen. Excess air exhausted from the test chamber via a 25 cm square pori through which the sampling duct entered. With the entire systei operational and a hair dryer operating, a positive pressure in the hood oi approximately 0.15 cm 1120 was obtained. This pressure was low enough to preclude any significant, effect on hair dryer operation. The aij velocity through the exit port was high enough ( 100 cm/sec) to prevent turbulent back diffusion of ambient air into the hood. That portion of tht test s ystem in which the dryer was placed is herein referred to as thi clean air hood.
A dry box glove was fitted to the side of the hood to permit manipulation of the hair dryer controls during a test run without contaminating the hood with ambient air.
The air exhausting from the sampling duct was fed back into the inlet
of the test tunnel HEP filter to prevent potential
the laboratory.
.
asbestos
escape
intc
A velocity profile was obtained in the return air duct in order tc.
estimate the total air flow through the clean air supply. The velocity it
the 12.7 cm diameter duct was uniformly 762 cm/sec indicating a flowrate of
3
5.78n/min.
.
The sampling duct assembly consisted of a one meter length of 18 cn diameter duct and various tapered adapters which allowed direct connectior to the outlet of various shaped hair dryers. The duct was selected to be
-4-
C01G
GI00016
large enough to easily contain three side by side '37 on filter cassette
samplers. Millipore
The sampling protocol was subsequently changed to use a single
3*
aerosol open-type 47 nn filter holder with a stainless steel body
and support screen. The walls of the duct and tapered sections were coated
with oil to prevent reentrainment of particles fron the surface of th
duct, thereby assuring that particulate from any one dryer would not be
detected during subsequent tests.
Based on w o r k by Liu and Agarwal (S) the losses in the duct of part
icles smaller than S us aerodynamic diameter were expected to be less tha
10Z for the flowrates of all the hair dryers tested. The air "flow througl
the duct for these flowrates was in the turbulent regime indicating that
the potential source of any primary particle losses expected would bt
turbulent i m paction on th of the duct rather than gravitational settelini
of the particles.
Sampling the hair dryer air supply and effluent was accomplished b;
using 37 mm and 47 mm filter cassettes, respectively, and 0.8 um po.n
size mixed cellulose ester membrane filters. These filters have greate
than 99Z effic i e n c y for all particles of interest (6).
A vacuum pump was used to draw 69.4 liters per minute of air throug'
the 47 mm filter cassettee. The sampling system was calibrated using a
American Meter Company 150 liter spirometer. An MSA Model C pump was use
to sample the supply air at 2 liters per minute with a 37 mm open-fac
cassette. C a l i b r a t i o n of this system was accomplished with a soap fil
bubble meter.
-5001 f
GI00017
Sampling at 69-4 L/min allowed collection of a sufficient volume of effluent in a reasonable amount of time to allow an accurate determination of airborne particulate concentrations. Any possible error because of the resulting anisokinetic sampling was judged negligible since the major source of error lies with particles larger and heavier than those expected from the hair dryers. Also, most treatments of anisokinetic sampling error assume laminar flow in the sample stream. As stated previously, the flow in the sampling duct was turbulent and not laminar.
Three different real time particle monitors were used during the assembly and initial testing of the hair dryer test system. These instruments included, a E.oyco Model 225 connected, to a multichannel analyzer, a Particle Measuring Systems (PMS) ASAS-X particle spectrometer and a ' CCA Fibrous Aerosol Monitor (FAH). All of these instruments detect particles by their light scattering properties.
The Royco Model 225 was used to determine the uniformity of distribution of particles across the sampling duct. Monodisperse, 12 urn potassium biphthalate particles were generated using a TSI, Berglund-Liu generator. These particles were injected into the duct just downstream of an operating hair dryer which produced a duct air velocity of 58 cm/sec. A probe connected to the Royco particle counter was Inserted into the duct at the sampling location and nine representative locations across the duct were sampled. The coefficient of variation at these nine traverse ppint locations was less than 0.08, indicating acceptably uniform distribution of particles within the duct. Sampling the hair dryer effluent at various locations within the duct was thus expected to be r eprsenttive of the
-6-
0018
GI00018
entire effluent.
The PMS ASAS-X aerosol spectroneter was used to monitor the
effectiveness of the air cleaning system. Particles in the 0.15 to 0.30 um
range were monitored with the ASAS-X since this size produced a rapid
instrument response and was expected to have the highest penetration into
the clean air system. Ambient particle concentrations (0.15 - 0.30 um)
were reduced by a factor of 40 in the clean air hood (see Table 1).
Background filter samples were found to be quite clean by electron
microscopy! so no further effort was made to. reduce this concentration.
The production of particles by some of the hair dryers was also noted with the ASAS-X.
TABLE I
'
Particles Larger than 0.15 um Using ASAS-X Spectroneter .
3
Ambient air
35-50 particles/cm
.
Clean air hood
'
Test duct, dryer on
1-2 particles/cn^
3 2-4 particles/cm
These particles were apparently generated by motor bearing or electrical
brush wear, although these concentrations were barely above the clean air
background.
.
The clean air sy s t e m was found to be entirely adequate to supply air to
all the dryers. Using the ASAS-X, it was found that the particle c o ncen
tration in the hood was brought down to its baseline level less than one
minute after the high volume blower was turned on.
The third monitoring instrument used was the FAH. This device was used
-7-
0019
GI00019
to indicate the fiber concentration in the hair dryer effluent. The FAM responds only to the larger fibers (and not just to asbestos) visible by light microscopy. The FAM was used with several hair, dryers. In some cases, a single fiber was noted in a two hour period, and in others, none were detected. A one fiber count in a two hour period indicated approximately 0.01 fibers/cc. The statistical significance of one fiber counted in the size range limitations of the FAM was questionable for this study. Use of the FAM on this study was discontinued because of its lack of sensitivity at such low concentrations. It should be noted that the,FAM was designed to operate primarily in the 0.1 to 20 fiber/cc range to meet the requirements of the OSHA standard for asbestos (7).
Sampling Procedure
.
Before positioning the dryer to be tested in the clean air hood, the appropriate reducer was attached to the sampling duct. Various size reducers were fabricated to ensure the best interface possible between the dryer and sampling duct. The dryer was firmly clamped into position and sealed to the sampling duct reducer with duct tape. The dryer was then plugged Into the power supply located inside the clean air hood. The clean air supply blower was then turned on and allowed to flush the clean air hood for 15 minutes and the dryer was then turned on. An air velocity profile was determined in the sampling duct using a Sierra Instruments Model 440 thermo-anemometer. A uniform velocity profile indicated a good placement of the dryer. If the velocity profile indicated nonhoraogeneous flow, the dryer was repositioned to produce uniform flow. Dryer velocities
- 8
0020
GI00020
were determined with a Taylor rotating vane anemometer. Dryer flow rates
were also checked by interfacing a 2 inch plastic pipe to the dryer inlet
nd determining the air velocity with the thermo-anemometer.
A 47 mm diameter filter, Millipore AAWP, was placed in the stainless
steel filter holder and the assembly placed in the sampling duct. Also, a
37 m e filter, Hillipore AAWP preloaded in a styrene open-faced cassette was
positioned inside the clean air hood near th.e dryer inlet. Pumps for both
filter samplers were started and the dryer effluent was sampled for 2
hours. The dryer was accessed when necessary during the high-heat-lov-heat
cycle via the glove port in the clean air hood.wall. At the end of the
sampling period the 47 mm filter sample was removed from the filter holder
and carefully placed in a 47 mm petri dish and brought to the TEM
laboratory for examination. Background samples were obtained both in the
clean air hood and at the end of the sampling tunnel while operated without
a dryer in the test chamber*
.
TEH Analysis
'
The asbestos analyses for the study were performed on a JEQL 100B electron microscope equipped with both selected area electron diffraction (SAED) and energy dispersive analysis of x-rays (EDAX). The microscope magnification was calibrated using 0.5 uo Latex spheres, and during the course of the study Individual fibers were Identified on a random basis by diffraction patterns and metal content.
Due to the light loading of fibers seen on samples obtained early in the study, the decision was made to scan the entire grid in order to
-9-
0021
GI00021
Co acquire a representative sample* Each grid contained approximately 200 fields each measuring 80 x 80 un. Counting time varied from 2 hours for lightly loaded samples to 3.5 days for the most heavily loaded samples. Background samples o.f the supply air shoved very clean, fiber free filters. A detection limit of one fiber per grid would result in a sensitivity of 9 x 10 5 fiber/cc. Representative photomicrographs are presented in Appendix 1. Sample Preparation
. The Millipore AA filters used in sampling the- effluent from the hair dryers were prepared for analysis following the standard HIOSH procedure described in Technical Information Bulletin $77-204 (8). A disk was removed from the center of each filter with a No. 5 cork bore. The sample disks were affixed to a clean glass slide and allowed to clear in acetone vapor for 5 minutes. The samples were then coated with a thin carbon film .n a vacuum evaporator to provide an electron beam transparent surface to which the collected particles could adhere. After coating the cleared filter disks were cut out and placed upside down on pre-coated 200 mesh copper grids which had been placed in a petri dish on absorbent Whatman $41 filters. The Whatman filters were carefully saturated with acetone and left to sit overnight to allow complete dissolution of the sample filters. When dry, the preparations were ready for analysis by electron microscopy.
Fiber Count
The sample grids were scanned initially to ensure that at least 70S of the preparation remained intact. A fiber search was carried out at a magnification of 1700X and fibers were sized and counted at a magni f i c a t i o n of 10,000X. Fiber clumps and bundles which exhibited unequal or ambiguous
-in .
0022
GI00022
dimensions were "sized in segments or were ass-igned an average diametc
based on 3 or more measurements. In all cases, multiple measurements' takei
on fiber bundles, clumps, and clusters were bracketed in the data record t
indicate that they be treated as a single airborne structure in calculatin
air concentrations.
The length and diameter of each individual fiber was determined t
allow calculation of the volume of each fiber. Calculating the volume o
each fiber allowed an accurate estimation of fiber mass. The onl
assumption made was that each fiber approximated a solid cylinder.
All recorded data were reduced by computer to obtain air concentration
and fiber size distributions. A description of the calculation can b
found in A p p e n d i x I, Test Data.
..
Summary
.
'
During the testing program conducted for CPSC, 30 dryers were tested Of these, 25 were home use hand-held appliances, 3 were table-top hood models, one was a hobby heat gun, and one was a heavy duty commercial sale style dryer. A i r b o r n e asbestos concentrations generated by these dryei ranged from 0 to 0.11 structures/cc and the mass concentrations ranged fre 0 to- 7652 ng/o^. During the test program, one asbestos fiber was detected in the entire group-of background samples. The pooled results < these background samples resulted in a b ackground concentration of 3 10"5 fibers/ec.
The pairs of results obtained by running each hair dryer on high he versus cycled heat were used to determine an upper limit on the v a r i a b i l i of the sampling and analysis. The geometric mean of the ratios of t
-11-
0023
GI00023
5 tructurc-s /cc concentrations of high heat to cycled heat for 21 pairs of non-zero results was 1.19 with a 95X confidence interval of 0.82 to 1.73. Thus, the successive sample ratio for each dryer cannot be' considered significantly different from unity, indicating no significant differance between samples taken at high heat or at cycled heat. The paired samples were evaluated to find the variability due to sampling and analysis techniques. The geometric standard deviation was used to determine the upper and lower 95Z confidence limits on any measurement, N. These limits can be determined by respectively multiplying and dividing N by the factor 3.4. In other words, at a 95X confidence the true value for any measurement, N, is between N X 3.4 and N/3.4. '
Figures 2 and 3 show frequency distribution graphs of the hair dryer test results as a function of the number of asbestos structures emitted, and the mass of asbestos emitted, respectively. In each figure, th bar on the extreme left indicates the number of dryers from which aero emissions were observed.
- 12-
C024
GI00024
REFERENCES
1. "Asbestos Discharge fron Six Hair Dryers in a Two-Hour Test". El'V
Associates, March 19, 1979.
'
2. "Hair Dryer Asbestos Enissions". Health, Safety and Environment
Department, Johns-Manville Corporation, April 10, 1979.
.
3. "Asbestos Analyses:
Son-of-a-Gun Hair Dryers Model TD-1 and TD-2".
Report to Clairol, Inc. by Wa l t e r C. McCrone Asssociates, Inc., April
30, 1979.
.
.
A. "Examination of Hair. Dryers from CPSC (#7166 and # 7267 ) for Asbestos". Memorandum to Consumer Product Safety Commission from U.S. Department of Commerce, National Bureau of Standards, May 2, 1979.
5. Liu, B. and Agarual, J. Experimental Observations of Aerosol Deposition in Turbulent Flow. Aerosol Science, 5:145, 1974
6. A i r Sampling Instruments from Evaluation of Atmospheric Contaminants,
5th Edition. American Conference of Governmental Industrial
Hygienists, p N-6, Cincinnati, Ohio 1978.
~
7. OSHA Occupational Safety and Health Standards. Federal Regulations, Part 1910.1001, Asbestos.
Title 29, Code of
8. Zumwalde, R.D. and Dement, J.M. Review and Evaluation of Analytical Methods for Environmental Studies of Fibrous Particulate Exposures. DHEW (NIOSH) Publication Ho. 77-204. U.S. Department of Health, Education, and Welfare, Public Health Service, Center for Disease Control, National Institute for Occupational Safety and Health, Cincinnati, Ohio.
-13-
0025
GI00025
Figure 1. Schematic of Test System -14-
0026
GI00026
Number Concentration Frequency
20 -,
1 CO CD 15 -
XI
u
cd
10 -
0 3
5 J
zZS;
LI yA
\ 0 " `b
lO"5
1 v O " 12,
&
\0"v
Number of Fiber Structures per cc
Figure 2
-15-
0027
GI00027
Mass Concentration Frequency
Figure 3 -16-
0028
GI00028
APPENDIX I
. SAMPLING
TEST DATA AND
AND ANALYSIS
INFORMATION
1. Sanpling race: 69.4 L/nin (2.45 cfn)
2. Sanpling cine: 2 hours
3. Fiber councs are presented as follows:
I Individual fibers not pare of a clunp or bundle
B/C - Nunber of bundles or clunps
T - Nunber of individual fibers (I) plus the number of fibers contained in each clump or bundle
4. The structures/cc calculation treats each bundle or clunp as one airborne structure e.g.: froc a count of I 5, B/C ), and T 45... the nunber used to calculate structures/cc would be I + B/C - 12.
Structures/cc - (FC/TEM) x ECA
VOL
FC - Total structures counted (I + B/C)
TEM - TEM grid area examined (on )
_
ECA - Effective filter collecting area (960 on j
VOL - Sample volume in cc
Example Calculation:
If: 1 - 5 5
TEM - 1.22 m m 2
. B/C - 30
VOL - 8328000 cc
.
Then: Airborne structures/cc - (85/1.22)960 0.008
(8328000)
'
If effluent volume is 170 ra2 , total a i r b o r n e structures in effluent - (0.008 s t r uctures/cc) x (1.7 x 105*8 cc) - 1.36 X 10 structures
5. The volume of each fiber counted, both individual fibers and those in clunps (T value), is calculated and its mass d e t e r m i n e d using a density of 2.4 grans/cc for chrysotile asbestos. Tota.1 fiber mass as reported is a sum of individual massess.
-17-
.
.
0029
GI00029
Sample Number: D-8 70-5361
.
'ianufacCurer/Uistributor: New York Merchandise Co.
Dryer Mane: ' Mighty 1200
.
Model/Series: Modell0/2100
.
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flow Rate (L/nin): Effluent Volune (L): Sample Volume (L): Airborne Asbestos
Structures Counted:
Hich Heat 673 8.1 X 10* 8 328
1-171 B/C-4
T-181
Hip.h-H eat -Low-Heat 673 8.1 X 10* 8328
1-23 B/C-l
T-25
Airborne Structures/cc: Jtal Structures in Effluent: 3
Fiber Mass (ng/n ):
Total Fiber Mass in Ef fluent (ng):
Fiber Length Range (u b ) :
M ean Fiber Length (u b ):
Fiber Diameter Range (urn):
Mean Fiber Diameter (u b ):
Total TEH Fie ield Area Examined (am ) :
1.6 X 10" 2 1.3 X 106 13.9
1121
'
0.6-26
3.7
0.05-1.2
0.21
1.24
7.1 X 10" 3 5.7- X 105 8.8
709 . 0.8-23
4.1 0.005-0.8 0.22
0.39
I-Individual Fibers B/C-3undles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Number of Fibers in Bundles or Clumps
-18-
0030
GI00030
Sample Dunbar: U-S35-3535
Manufacturer/Distributor: Schick
'
Dryer Wane: Shick 1000
llodel/Series: PD-100.1A
Asbestos Use and Co nncnts: Used, hand --held hair dryer The asbestos insulation was present as a tubular lining to the barrel.
Dryer Flow Rate (L/nin):
Effluent Volume (L):
Sample Volume (L): Airborne Asbestos
Structures Counted:
Hiflh Heat 2632 3.16 X 105 832S
. Hiah-Heat-Low-Heat Cycle
2632
3.16 X 105
-
8328
"
1-6 B/C-0
T-6
1-13
B/C-2
T-20
irborne Structures/cc:
5.2 X 10~A
Total Structures in Effluent:
1.6 X 105
3 Fiber Hass (ng/m ):
C. 22
.
Total Fiber Hass
in Effluent (ng):
71
Fiber Length Range (uo):
0.8-13.2
Mean Fiber Length (un):
5.0
Fiber Diameter Range (ua):
0.06-0.3
Mean Fiber Diameter (urn):
0.2
Total TEM Fielg Area Examined (am ):
1.32
. 1.3 X 10" 3
4.1 X 105
2.2
693 0 .7-9.0 3.5 0.05-1.2 0.2
1.3
I-Individual Fibers B/C-Bundles or Clumps
1+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Humber
0031
GI00031
Sample Number: CPSC-2 lianufacturer/Distributor: General Electric Dryer Kane: Power Turbo 1200 Watts liodel/Series: .Sl-5115-0 Asbestos Use and Comments: Used hand held hair dryer. The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flow Rate (1/min): Effluent Volume (1): Sample Volume (1 ): Airborne Asbestos
Structures Counted:
High Heat 1089 135161 8328
1-8 B/C-4
T-29
Airborne Scructures/cc: Total Structures in Effluent: Fiber Mass (ng/n3): Total Fiber Mass
in Effluent (na): Fiber Length Ranze (urn): Mean Fiber Length (ua): Fiber Diameter Range (un): Mean Fiber Diameter (um): Total TD-I Fiel^ Area
Examined (mm ):
1.4 X 10" 3 1.9 X 105 15
2027 0.6-15 3.8 0.05-1 0.25
0.98
High-Heat-Low-Heat 1089 135'.61 8328
1-5
B/C-l
.
T-9
6.5 X 10`A 1.1 X 105 13
1757 1.3-11.5 3.8 0.1-1 .3 0.31
1.07
I*Individual Fibers B/C-Bundles or Clunos
.
revised 6/3/1980
I+B/CAirborne Structures Counted T-Individual Fibers Plus Estimated Number of Fibers in Bundles or Clunos
0032
GI00032
Sande Kur.ber: E-100-375 lanufacturer/Distributor : General Electric Dryer Nane: Super-Pro 1400 Model/Series: S1-5H2-0 Asbestos Use and Coonents: Used, hand held, hair dryer. The asbes insulation was present as a tubular lining of the barrel
Dryer Flow Rate (1/min): Effluent Volune (1 ): Sample Volune (1 ):
Airborne Asbestos Structures Counted:
Hizh Heat 1398 167760 8328
1-37 B/C-0
T-37
Hifih^Heat-Lov-Heat
1398
167760
'
8328
1-8 B/C-l T-10
Airborne Structures/cc:
Total Structures in Effluent:
Fiber Mass (ng/o3):
Total Fiber Mass in Effluent (ng):
Fiber Length Range (un):
Mean Fiber Length (un):
fiber Diameter Range Cun)!
Mean Fiber Diameter (un):
Total TEH Field Area Exanined (no2):
3.6 X 10" 3 6 X 105 0.44
73.8 0.8-23 4.7 0.05-8 0.2
1.19
l.l X 10" 3 1.8 X 105 0.69
168 ' 1.8-13 5.7 0.15-1.4 0.4
0.95
I-Individual Fibers B/C-Bundles or Clunps
*revised 6/3/1980
I+B/C*Airborne Structures Counted T-Individual Fibers Plus Estiaated Nunber of Fibers in Bundles or Clumps
C03 a
GI00033
Sanple Number: CPSC-8
i.cnufacturer/Dis:ributor: Dryer Kane: Norelco 1000
North American Phillips Corp. '
Mode 1/Series : UB1700
,
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos insulation was present as a tubular lining
of the barrel
Dryer Flow Rate (L/nin): Effluent Volume (L): Sanple Volume (L): Airborne Asbestos
Structures Counted:
High Heat 849 95880 8328
1-18 B/C- 6
T-30
High-Heat-Low-Heat Cvrlo
849
' 95880
3 32 8 -
1-21 B/C-6
T-56
Airborne Struetures/cc: Total Structures in Effluent: Fiber liass (ng/a^) : Total Fiber Mass
in Effluent (ng) : Fiber Length Range (urn): Mean Fiber Length (urn): Fiber Diameter Range (un): Mean Fiber Di ameter (un): Total TEM Field Area
Examined (aa j :
2.5 X 10" 3 2.4 X 105 15
1438
0.5-12
3.4
0.05-2
0.31
'
1.2
2.7 XIO- 3 2.6 X 105 8.6
1822
:
. *
0.7-22
3.2
0.05-1.2
0.23
1.25
1-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of F i b e r s in B u n d l e s or C l u m p s
Number
- 20-
0034
GI00034
Sample Number: E-100-352
lianu fact urer/Lis cribu tor: Conair
.
jryer Name: Prostyle 1200
Ilode 1/Series : 065
Asbestos Use and Comments: Used, hand-held hair dryer* The asbestos insulation was present as a tubular lining of- the barrel.
Dryer Flow Kate (L/min): Effluent Volume (L) : Sample Volume (L) :
Airborne Asbestos Structures Counted:
Kinh Heat 1284 154080 8323
1-1 B/C-0
T-l
High-Heat-Low-Heat Cycle
1284
154080
8328
-
1-4 B/C-0
T-4 '
Airborne Structures/cc:
Total Structures in Effluent: 3
Fiber Mass (ng/a ):
Total Fiber Mass . in Effluent (ng):
Fiber Length Range (um):
Mean Fiber Length Cum):
Fiber Diameter Range (um):
Mean Fiber Diameter (um):
Total TEi-i Fielg Area Examined (mia ) :
1.15 X 10" 4 1.77 X 104 0.096
14.7 no range 7 . 1 no range 0.25
1.0
4.2 X I 0 ~ l 6.5 X 104 7.7
1.2 X 10J 3.8-36 12.9 0.05-1 0.5
1.05
I-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Humber . of Fibers in Bundles or Cluaps
- 21-
C035
GI00035
S an l e Nunber: E-- 100-- 377
Manuf a c tu r e r / D i s t r i b u c o r : Ge n e r a l E l e c t r i c '
.
Dryer 'Jane: Power Pro 1000
Mode 1/ Seri es : 5105-013
Asbestos Use and Comments: Used, hand-held hair dryer The asbestos insulation was present as a tubular lining of the barrel
Dryer Flow Kate (L/nin)i
Effluent Volume (L): Saaple Volume (L): Airborne Asbestos
Structures Counted:
High Heat
1035
124200
8328
'
1-16 B/C-l
T-l 8
High-Heat-Low-Heat Cycle
1035
124200
.
8 3 28
"
1-92
B/C-6
T-108
Airborne Structures/cc:
Total Structures in Effluent:
Fiber Mass (ng/n3):
.
Total Fiber Mass in Effluent (ng):
Fiber Length Range (un):
Me a n Fiber Length (un):
Fiber Diameter Range (un):
Mean Fiber Dlaaeter (un):
Total TEn Fielg Area Examined (am ):
1.7 X 10" 3 2.1 X 105 29
361 0.8-25 6.9 0.03-0.7 0.25
1.17
0
1 in o
o
9.3 X 10" 1.2 X 106 17
2148 0.7-45 5.2
0.22
1.2
I " I n i vi du al Fibers B/Ciiundles or Clumps
I+B/C-Airborne Structures Counted
T-Individual Fibers Plus Estiaated Number
of Fibers in Bundles or Clumps
'
- 22-
C036
GI00036
Sanple Number: E - 840-5924 iianu factu re r /D ist ribu tor : Zayre Corp.
. '
Dryer Name: 1 200 Foldaway
Mode1/Series: JK-115
Asbestos Use and Comnents: Hand-held hair dryer. The asbestos insulation was present as a lining to the barrel
Iiryer Flow Rate (L/min): Effluent Volume (L):
Sample Volume CL)! Airborne Asbestos
Structures Counted;
High Heat
418 170160 8328
1-7 B/C-l
T-l 3
High-Heat-Low-Keat Cycle
415
`
170160
8328
-
1-1 B/C-0
T-l
Airborne Structures/cc:
Total Structures in Effluent:
3
Fiber Mass (ng/n ) :
7 X 10" 4 1.2 X 105 35
Total Fiber Mass in Effluent (ng):
Fiber Length Range (urn);
Mean Fiber Length (urn); Fiber Diameter Range (urn):
6609 1.0-25 ' . 8.6 C.03-3.0
o
On
Mean Fiber Diameter (um)s
Total TEM Fielg Area Examined (mm ):
1.31
' .
o
X 00
H
1.1 X 10"
0.098
' 16 no range 5.3 no range 0.3 1.06
I-Individual Fibers B / O S u n d l e s or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Number of Fibers in Bundles or Clunps
0037
GI00037
Sanple Number: E-100-361
Manuiacturer/L'istributor: Hamilton Beach
.
Dryer Ilane: Crooner II
.lodel/Serles: 423
Asbestos Dse and Comments: Used, hand-held, coab type dryer* ihe asbestos was present as a lining to the barrel*
Dryer Flow Rate (L/min): Effluent Volume (L): Sample Volume (L):
Airborne Asbestos ' Structures Counted:
High Heat 184 19017 8328
1-7 B/C-3
T-l 7
High-Heat-Low-Heat Cycle Dryer has only one'settin
8 328
_
Airborne Structures/cc:
" 'tal Structures in Effluent:
Fiber Mass (ng/m3):
Total Fiber Mass
.
in Effluent (ng): '
Fiber Length R.ange (um):
Mean Fiber Length (um):
Fiber Diameter Range (um):
Mean Fiber Diameter (um):
Total TEM Fiel Area Examined (on ):
1.1 X 10"3 2.1 X 104 2.2
42 1-21 6.4 0.05-0 .8 0*25
1.06
I-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Kumber of Fibers in Bundles or Clumps
-25
'
0039
GI00039
Sanple Dumber: -100-376 Manufacturer/Distributor: Montgomery Ward
.ryer Mace: Montgomery Ward 1200
M o d e 1/Series: 53-19375 As bestos Use and Comments: Used, hand-held hair d ry e r The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flow Rate (L/min):
Effluent Voluce (L) :
Sample Volume (L): Airborne Asbestos
Structures Counted:
Hich Heat
1104
132460
8328
'
1-2 B/C-l
T-4
High-Heat-Low-Heat Cycle
1104
132480
<
8 32 8 "
1-5 B/C-0
T-5
'
`Irborne Structures/cc:
3.0 X 10" 4
Total Structures in Effluent : 4.0 X 104
Fiber Mass (ng/a^):
0.22
Total Fiber Mass
in Effluent (ng):
29
Fiber Length Range Cum):
3.5-17
Mean Fiber Length (urn):
9.75
Fiber Diameter Range (ua):
0.08-0.3
'
Mean Fiber Diameter (ua):
0.17
Total TEM Fiel^ Area Examined (mm ):
1.16
4.6 X 10" 4 6.1 X 104 0.16
21
1.5-5.5
3.44
0.07-0.4
0.2
;
1.25
I-Individual Fibers B/C-Bundles or Clumps
I+L/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Hunber
0040
GI00040
Sample Kuaber: E-10G-360 Manufaeturer/Distributor: Cille cce >ryer ane: 'Super Max
Mod e l/ Se ries : HD-5 .
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos was present as a component of the support for the heati ng element.
Dryer Flow Rate (L/cin): Effluent Volume (L): Sample Volume (L): Airborne Asbestos
Structures Counted:
Kish Heat 618 74 160 8328
1-314 B/C-24
T- 386
Hijrh-Heat-Low-11eat Cycle
618
74160
-
8328
"
1-177
B/C-8
T-206
' /
Airborne Structures/cc: vocal Structures in Effluent: Fiber Mass (ng/m3 ): Total Fiber Mass
in Effluent (ng) : Fiber Length Range (un): Mean Fiber Length (un): Fiber Diameter Range (un): Mean Fiber Diameter (un): Total TEM Fielg Area
Examined (mo ):
3.4 X 10"2 . 2.5 X 106 34
2.5 X 103 0.3-50 4.1 0.05-1.3 0.2
1.23
2.0 X 1C" 2 1.5 X 106 21
1.6 X 103 0.4-40 3.5 0.05-1.1 0.2
1.22
I-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Humber of Fibers in Bundles or Clunps
C041
GI00041
Sample iiunber: E-100-390
Ha nu factu rcr/D istri butor: Fraz ier
jryer liane: Frazier Slow Out Comb Styler
rode 1 /S e ri es : W-069-1
Asbestos Use ana Comments: Used, hand-held, comb type dryer The asbestos
was present as a conical lining around the heating element
* Uncountable due to high background level of amo rp hou s,opaque material
from the dryer. Insulation material in dryer was identified as
chrysotile asbestos.
.
** Low speed inoperative; therefore, only high heat test conducted.
High Heat
High --Heat--Low-Heat Cycle
Dryer Flow Rate (L/nin):
99
**
Effluent Volume (L):
11880
Sample Volume (L):
8328
Airborne Asbestos
Structures Counted:
*
Airborne Struetures/ee:
Total Structures in Effluent:
'
Fiber Mass (ng/m^):
Total Fiber Mass in Effluent (ng):
'
.
Fiber Length Range (urn):
-
Mean Fiber Length (ua):
-
Fiber Diameter Range (ui):
Mean Fiber Diameter (ua):
Total 7 EM Fiel Area Examined (so ):
IIndividual Fibers 3/C-Eundles or Clumps
I+B/CAirborne Structures Counted T-lndividual Fibers Plus Estimated Number of Fibers in Sundles or Clumps
0042
GI00042
Sanple Humber: E-- 100 --355 Manuf a ct urer/D is cr i bu tor : M o nt g o m er y i.'ard Dryer Name: Variable Power 1400 M o de 1/ S er i es : 5 2-1 9361 Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos was present as a tubular lining of the barrel.
Dryer Flow Rate (L/min):
Effluent Volune (L):
Sample Volume (L):
Airborne Asbestos
.
Structures Counted:
High Heat 1417 1.7 X 105 8328
1-28 B/C-5
T-41
High -Heat-Low-Heat Cycle
1417
1.7 X 105
8328
_
1-3 B/C-4
T-30
Airborne Structures/cc:
Total Structures in Effluent:
3
Fiber Hass (ng/in ):
Total Fiber Mass in Effluent (ng):
Fiber Length Range (an):
Mean Fiber Length (urn):
Fiber Diameter Range (urn):
Mean Fiber Diameter (urn):
Total TEM Fiel Area Examined (ram ):
3.1 X 10~3 5.3 X 105 3
5.15 X 102 0.5-48 4.9 0.03-0.7 0.19
1.18
o
CM
O
o
1.1 X 10~ 3 1.9 X 105 0.35 60 0.7-10.5 2.9
0.12 1.16
I-Individual Fibers B/CBundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Mu mb e r
- 29-
C043
GI00043
Sample Number: E-100-375
.
Manufacturer/Distributor: General Electric
Dryer Name: Super-Pro 1A00
Mode 1 /S eri es : Sl-5112-0
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos insulation was present as a tubular lining of the barrel.
. Dryer Flow Rate (L/rain): Effluent Volume CL): Sample Volume (L): Airborne Asbestos
Structures Counted.
High Heat 1398 1697760 8328
1>37 B/C-0
T-37
Airborne Structures/cc: Total Structures in Effluent: Fiber Mass (ng/n3) : Total Fiber Mass
in Effluent (ng): Fiber Length Range (urn): Mean Fiber Length (um): Fiber Diameter Range (um): Mean Fiber Diameter (uc): Total TEM Field Area
Examined (am;:
3.6 X 10" 3 6 X 105 0.44
740 0.8-23 4.7 0.05-8 0.2
1.19
High-Heat-Low-Heat Cyel
' 1398
1697760
8328
..
1-8
B/C-l
T-l 0
: ;
1.1 X 10 1.8 X 10 0.69
1179
1.8-13
5.7
.
0.15-1.4
0.4
0.95
I-Individual Fibers B /C -Bu nd les or C lum ps
I+B/C-Airborne Structures Counted TIndividual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
- 30-
0044
GI00044
Sar.ple Nunber: E - 8 G 5 - 1 2 9 2
M a n u f a c t u r e r / D i s t ri b u t o r : Co n a i r Dryer Uar.e: Professional Elow Cocb
' '
iodel/S e r i e s : Model 067
Asbestos Use and Connents: Used, hand-held comb type dryer.
The dryer was of a configuration such that the inside could not be inspected for asbestos position.
Dryer Flow Rate (L/nin): Effluent Volume (L): .Sample Volume (L): Airborne Asbestos
Structures Counted:
Hich Heat .
98.7
11844
8328 '
Hij^h-Heat-Low-Heat Cvcli
'
98.7
'
11844
8328
"
1-0 B/C-0
T-0
'
1-1
B/C-0
T-l
' '
Airborne Structures/cc:
Total Structures in Effluent:
Fiber Mass (ag/m3 ):
Total Fiber Mass in Effluent (ng):
Fiber Length Range (un):
Mean Fiber Length (urn):
Fiber Diameter Range (un):
Mean Fiber Diameter (un):
Total TEM Fiel^ Area
Exanined (no4):
'
0.98
. '
9.1 X 10" 5 1.1 X 103 0.02
0.25
no range
20
no range
.
0.25
1.27
I-Individual Fibers B/C=5undles or Clunps
I+B/CAirborne Structures Counted TIndividual Fibers Plus Estimated Number of Fibers in Bundles or Clunps
C045
GI00045
Sample Number: CPSC-3 Nanufacturer/Distrifcutor: Dryer Name: Sears 1000
Sears
iiodel/Series: 25 3-8 75-4
.
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flov Rate (L/min): Effluent Volume (L): Saaple Volume (L): Airborne Aabestos
Structures Counted:
High Keat 863 103560 8328
1-267 B/C-16
T-304
H i g h - H e a t - Low- He at CvcTe 863 103560 8328
1-139 B/C-10
T-163
Airborne Struetures/cc: Jtal Structures in Effluent:
Fiber Hass (ng/m2 ): Total Fiber Hass
in Effluent (ng): Fiber Length Range (um): Me a n Fiber Length (urn): Fiber Diameter Range (ua): Me an Fiber Diameter (um): Total TH Field Area
Examined (mia ):
0.031 3.2 X .10 16
1.6 X 10 0.3-55 3.5 0.02-0.9 0.12
1.15
0.016 1.6 X 106 1.9
2 X 102 0.4-24 2.5 0.02-0.5 0.1
1-11
I-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-32-
0046
GI00046
5ample Number: E-100-354
'anu fa c turer/bis t ribu to r : Uartaan
.
Dryer Name: PRO 1000
Hodel/S eri e s :
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flow Rate (L/ain): Effluent Volume (L) : Sample Volume (L): Airborne Asbestos
Structures Counted:
High Heat 696 83400 8328
1-32 B/C-8
T-64
Airborne Structures/cc: Jtal Structures in Effluent:
Fiber Mass (ng/m3 ): Total Fiber Hass
in Effluent (ng): Fiber Length Range (us):
Mean Fiber Length (un): Fiber Dia met er Range (urn): Mean Fiber Diameter (un): Total TEH Fiel| Area
Examined (nm ):
4.4 X 10" 3 3.7 X 105 5*3
439 0 .8 - 1 2 3.3 0.05-1.4 0.22
1.13
High-Heat-Low-Heat Cycle
696
83400
8328
-
1-9 B/C-5
T-2 7
1.5 X ,10" 3 1.3 X 105 1.4
118
0.4-14
3.2
.
0.05-1.0
0.18
1.13
I-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-33-
C047
GI00047
Sample Number: CPSC-2
Mar.uiaccurer/Distribu tor: General Electric
.
Dryer Name: Power Turbo 1200 Watts
.
M o d e l / S e r i e s : S 1-- 5115--0
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flow Rate (L/nin): Effluent Volume (L): Sample Volume (L): Airborne Asbestos
Structures Counted:
High Heat 1089 39960 8328
1-8 B/C-4
T-29
Hlnh-Heat-Low-Heat Cycle
1089
39960
8328
-
1-5 . B/C-l
T-9
Airborne Structures/cc: lotal Structures in Effluent: Fiber Mass (ag/m3 ): Total Fiber Mass
in Effluent (ng): Fiber Length Range (urn): Mean Fiber.Length (urn): Fiber Diameter Range (un): Mean Fiber Diameter (un): Total TEK Fielg Area
Examined ( m m ; :
1.4 X 10" 3 5.6 X 105 15
604
0.6-15
3.8
.
0.05-1
0.25
0.98
6.5 X 10" 4 2.6 X 1 0 5 13
5 36
1.3-11 .5
3.8
0 .1 - 1 .3
.
0.31
1.07
I"Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted TIndividual Fibers Plus Estimated of F i be rs in B u n d l e s or Clumps
Humber
0048
GI00048
Sample Humber: F.-- 100 --359
Manufacturer/Distributor: Korvettes
Dryer. N a m e : S u pe r . 1400
'
ilodel/Series : 1IA-1214S
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos was present as a tubular lining of the barrel.
Dryer Flow Rate (L/nin): Effluent Volume (L) : Sample Volume (L) : Airborne Asbestos
Structures Counted:
High Heat 1064 127680 8328
1-1 B/C-l
T-3
Airborne Structures/ec:
Total Structures in Effluent: 3
Fiber Hass (ng/a ):
Total Fiber Mass in Effluent (ng):
Fiber Length Range (urn):
Mean Fiber Length (un):
Fiber Diameter Range (urn):
Mean Fiber Diameter (um):
Total TEM Field Area Examined ( m m ; :
1.9 X 10" 4 2.4 X 104 0.23
29
1.5-9.5
4.5
.
0.15-0.6
0.35
1.2
High-Heat-Low-Heat C v c U
1064
127680
8328
"
1-0
`
B/C-0
T-0 '
"
1.24
l" Individual Fibers B/C-Bundles or Clumps
.
I+B/CAirborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-35-
CO 49
GI00049
Sample Number: C^SC-l i.anuiuccurvir/Miseri butor:
5a ny c i Corp.
Dryer Name: Sanyei Corp.
.
Model/Serics: E-2100
.
.
Asbestos Lse and Comments: Used) hand-held hair dryer* The asbestos insulation was present as a tubular lining of the barrel.
Dryer Flow Rate (L/min): Effluent Volume (L): Sample Volume (L): Airborne Asbestos
Structures Counted:
High Heat 1104 132480 8328
1-256 B/C-27
T-318
High-Heat-Low-Heat Cycle
1104
.
132480
8328
"
1-141
B/C-l5
T-181
` .
Airborne S triicture s /cc: Total Structures in Effluent: Fiber hass (ng/n^): Total Fiber tlass
in Effluent (ng): Fiber Length Range (ua): Mean Fiber Length (uo): Fiber Diameter Range (urn): Mean Fiber Diameter (uo): Total TEM Fielg Area
Examined (mta ):
2.9 X 10" 2 3.8 X 106 8.7
1200 0.5-42 2.6 0 .0 1 - 1 0.14
1.25
\0
o
H X
o
e CM
1.5 X 10" 2
4.3 560 0.3-35 3.0 0.03-7 0.14 1.23
I-Individual Fibers B/C-Bundles or Clump's
I+E/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clunps
Number
-36-
coso
GI00050
Sanple iiui..ber: CPSC-9 lianufacturer/Distributor: General Electric Tryer Hare: Super-Pro 1400 flodel/Serios : S 1-5112-0 Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos was present as a tubular lining of the barrel. * Fiber dimensions could not be determined
Dryer Flow Rate (L/nin): Effluent Volume (L): Sanple Volume (L): Airborne Asbestos - Structures Counted:
High Heat 1398 167760 8328
1-0 B/C-l
T-2
High-Heat-Low-Heat Cycle
1398
167760
8328
- .
1-0 B/C-l
T-l
Airborne Struetures/ec: otal Structures in Effluent:
Fiber Mass (ng/n2): Total Fiber Mass
in Effluent (ng): Fiber Length Range (un): lean Fiber Length (un): Fiber Diameter Range (un): lean Fiber Di aneter (un): Total TEM Fiel Area
Exaained (un ):
1 X 10" A 1.7 X 10A 1 . 1 x io" 2
1.9 1.5-2.5 2.0 0 . 0 5 - . 15 0.1
1.17
1 X 10~ 4 1.7 X 10 *
0.96
I"Individual Fibers B/C3undles or Clumps
I+3/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bu ndles or Clumps
Humber
-37
0051
GI00051
Sample. N u m b e r : E - 1 0 0 - 3 5 3
iiur.ufucturer/Distributor:
Sunbeam
Dryer Name: Prof e'ssionaire .1000
.
Node1/Se ri e s : 52-9C
Asbestos Use and Comments: Used, hand-held hair dryer. The asbestos was present as a tubular lining of the barrel.
Dryer Flow Rate (L/rain): Effluent Volume (L): Sample Volume (L):
Airborne Asbestos Structures Counted:
Rich Heat 967 116440 8328
1-1 B/C-0
T-l
Hiah-Heat-Low-Heat 987 118440 8328
1-1 B/C-0
T-l
Airborne Struetures/cc:
tal Structures in Effluent: 3
Fiber Mass (ng/m ):
Total Fiber Mass in Effluent (ng):
Fiber Length Range (un):
Mean Fiber Length (urn):
Fiber Diameter Range (urn):
Mean Fiber Diameter (urn): .
Total TEM Fielg Area Examined (mm ) :
1.1 X 10" 4 1.3 X 104
17 no range 4.6 no range 0.4
1.09
1.5 X 10" 4
.
1.8 X 104
3*1
no range
. 4.1
.
no range
0.15
0.75
I-Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborae Structures Counted T-Individual Fibers Plus Estimated of Fibe r s in B u n d l e s or C l u m p s
Number
-38-
G052 '
GI00052
Sample Number: E-100-374 Manufacturer/Distributor: Presto Mist Dryer Name: Presto Mist Hair Dryer Model/Series: PP-19A Asbestos Use and Comments: Used, table top hood type dryer. The asbestos insulation was
present as a sheet under the heating element.
Dryer Flow Rate (L/nin): Effluent Volume CL): Sample Volume (L):
Airborne Asbestos Structures Counted:
High Heat 1302 .
8328
1-12 B/C-0
T-12
High-Heat-Low-Heat .1302
.
8328
1-15 B/C-0
T-12
o i o H
X
H --f
Airborne Struetures/cc:
Total Structures in Effluent: Fiber Mass (ng/a3):
1.7 X 105 19.8
Total Fiber Mass in Effluent (ng):
3104
Fiber Length Range (urn):
1.3-48
`
Mean Fiber Length (um): V
Fiber Diameter Range (ua):
7.5 0.1-1.5
Mean Fiber Diameter (um):
0.3
Total TEli Field Area Examined (mm2 ):
1.22
OO
1.4 X 10~3 2.2 X 1 0 5 ' 0.278 43 1 .1 - 6
0.05-0.3 0.17 1.21
I-Individual Fibers B/CBundles or Clumps
1+3/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-40-
0054
GI00054
Sanple Number: CPSC-26
Manufacturer/!/iscrifcutor: Dryer Dane:
Westinghouse
Mode 1 /S eri es : H 10-2
Asbestos Us. and Coonents: Ds.d, table top bonnet type dryer.
position Of any asbestos insulation was not noted.
The
Dryer Flow Rate (L/min): Effluent Volume (L): Sample Volume (L):
Airborne Asbestos Structures Counted:
High Heat 277 33240 8328
1-0 B/C-0
T-0
Hich-Heat-Low-Heat Cyri-
277
33240
8328
-
1-0 B/C-0
T-0
Airborne Structures/cc: iOtal Structures in Effluent: Fiber Hass (ng/m^): Total Fiber Mass
in Effluent (ng): Fiber Length Range (um): Mean Fiber Length (un): Fiber Diameter Range (um): Mean Fiber Diameter (um): Total 7EM Field Area
Examined (mm 1.1
I" Individual Fibers E/C*Bundles or Clumps
I+B/C-Airborne Structures Counted
T-Individual Fibers Plus Estimated Kumber
of Fibers in Bundles or,Clumps
-41
0055
GI00055
Sample Humber: CPSC-22
'
lai:uiac tu re r/D is trihu to r : General Electric
Dryer Kane: Professional Hair Dryer
Hodel/Series: HD51
Asbestos Use and Comments: Used, table top hood type dryer, The asbestos was present as a pad under the heating element.
Dryer Flou Rate (L/cin): Effluent Volume (L): .Sample Volume (L): Airborne Asbestos
Structures Counted:
High Heat 2207 264340 8328
1-0 B/C-0
T-0
Bifh-Heat-Low-Heat Cycle
2207
264840
8328
-
1-0
B/C-0
.
T-0
Airborne Structures/cc: .'otal Structures in Effluents Fiber Hass (ng/m^): Total Fiber Mass,
in Effluent (ng): ^iber Length Range (urn): Mean Fiber Length (um): Fiber Diameter Range (um): Hean Fiber Diameter (un): Total TEM Field Area
Examined (mm ):
1.13
1.23
I-lndividual Fibers 3 / C - B u n d l e s or C l u m p s
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Number of Fibers in Bundles or Clumps
-42
0056
GI00056
Sanple Number:. E-- 850 --5327 Ha nu facturer/Distributor: Zonae Inc. Dryer Nan e : Eonse Blower Dryer Mode1/Series : Model 10 Asbestos Use and Comments: Used, stand mounted professional, dryer, The asbestos insulation was present as a lining to the barrel.
Dryer Flow Hate (L/min): Effluent Volume (L): Sample Volume (L) : Airborne Asbestos
Structures Counted:
High Heat 1044 125312 8328
1-650 B/C-137
T-1375
Airborne Structures/ee: Total Structures in Effluent: Fiber liass (ng/n3 ) : Total Fiber Mass
in Effluent (ng): Fiber Length Range (un): Mean Fiber Length (urn): Fiber Diameter Range (um): Mean Fiber Diameter (um): Total TEM Fiel Area
Examined (mm;:
0.11 1.3 X 107 7652 918211
0.15-95 7.1 0.04-15 0.4 0.83
High-Heat-Low-Hear Cycle 1044 125312 8328
1-450 B/C-72
T-720
- 0.08 9.6 X 10 6 651 78088
0.2-95 6.1 . 0.01-3.5 0.3 0.73
I-Individua1 Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-43-
057
GI00057
Sample Number: E-860-1440
'
Manufacturer/Distributor: Dryer Name: Super Zap
Clairol
Mode1/Series: SZ-1
'
Asbestos Use and Comments: Used, hand-held hair dryer. The insulation was present as a lining to the barrel.
Dryer Flow Rate (L/min): Effluent Volume (L): Sample Volume (L):
Airborne Asbestos Structures Counted:
Hieh Heat 687 82440 8328
1-18 B/C-l .
T-20
High-Heat-Low-Heat Cv c Ip
687
'
82440
8328
--
1-17
B/C-5
T-37
-
Airborne Structures/cc:
2 X 10- 3
otal Structures -in Effluent:
1.6 X 105
Fiber Mass (ng/n^):
1 .1
Total Fiber Mass
in Effluent (ng):
.
89
.
Fiber Length Range (uo): '
1.0-11.5
Mean Fiber Length (um):
3.5
Fiber Diameter Range (um):
eo o Ul o
e
Mean Fiber Diamet er (um):
Total TEM Field Area Examined (mm ; :
0.2 1.08
1.9 X 10" 3 1.6 X 15 9.6
789 0.9-31.5 5.0 . . 0.7-1.4 0.25
1.3
I-Individual Fibers B/ C- Bun dle s or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-44-
0058
GI00058
Sample Number: E-805-1291
Manufacturer/Oistributor: Jheri Redding
Jryer Name: Jr. Pro 1000
.
Ilode 1 / Series : 066
Asbestos Use and Comments: Hand-held dryer. Its asbestos insulation was present as a lining to the barrel.
Dryer Flow Rate (L/nin): Effluent Volume (L): Sample Volume (L): Airborne Asbestos
Structures Counted:
High Heat 829 99480 8328
1-360 B/C-17
T-410 .
Kigh-Heat-Low-Heat Cycle
829
99480
8328
"
1-148 B/C-8
T - 17 4
Airborne Structures/cc: Total Structures in Effluent: Fiber Mass (ng/m2 ): Total Fiber Mass
in Effluent (ng): Fiber Length Range (um): Mean Fiber Length (urn): Fiber Diameter Range (um): Mean Fiber Diameter (um): Total TEM Fielg Area
Examined (mm ):
3.3 X 10" 2 3.6 X 106 26
2627 0.3-43 3.2 0.03-1.2 0.18
1.3
. 1.4 X 10- 2 1.5 X 106 30
2975 0.1-95 4.9 0.0 5-1.5 0.2
1.32
I-Individual Fibers B/C-3undles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated .of Fibers in Bundles or Clumps
-45-
0059
GI00059
Sample Number: D-815-0580
Manufacturer/Distributor: Topflite
.
Dryer Kane: Monolcote Heat Cun
Mode1/Series: none present
Asbestos Use and Comments: Hand-held hobby heat gun. insulation was present as a lining of the barrel.
The asbestos
Dryer Flow Rate (L/min): Effluent Volume (L): Sample Volume (L) : Airborne Asbestos
Structures Counted:
Hich Heat
1S2
21840
8328
1-324 B/C-20
T-439
Hieh-Hent-Low-Heat Cvcle
182
21840
8 328
-
1-100
E/C-6
T-121
;
Airborne Struetures/cc: Jtal Structures in Effluent: 3
Fiber Mass (ng/m ): Total Fiber Hass
in Effluent ( n g): Fiber Length Range (urn):
Mean Fiber Length (ua):
Fiber Diameter Range (um):
Mean Fiber Di ameter (urn):
Total TEU Fielg Area Examined (mm ):
3.8 X 10" 2 8.4 X 105 4154
91395 0.8-90 6.3 0.05-13 0.36
1.05
1.3 X 10" 2
2.9 X 105
168
3700 0.4-60 6.2 0.03-3.5 0.33
0.93
1" Individual Fibers 3/C-Bundlcs or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated Number of Fibers in Bundles or Clumps
- 46-
C060
GI00060
Sample Number: E-840-4024
:.auufacture:/L'iscri jutor: Cer.air
I-ryer Name: Pro Style 1200 Watts
Iiodel/Series: Ho del 065 Series 0278
sbescos Use and Comments: Used, hand-held dryer. lio asbestos was present in the dryer. It was run as a control.
Dryer Flow Rate (L/nin):
Effluent Volume (L): Sample Volume (L): Airborne Asbestos
Structures Counted:
High Heat 1284 154080 8328
1*0 B/C-0
T - 0
Hig h - K e at-Lov-Keat Cv p Ip 1284 154080 8328
1-0 ' B/C-0
T-0
Airborne Strue Cures/cc: 'otal Structures in Effluent: Fiber Mass (ng/m^): Total Fiber Mass
in Effluent (ng): Fiber Length Range (urn): Mean Fiber Length (ua): Fiber Diameter Range (ua): Mean Fiber Diameter (ua): Total TEM Field Area
Examined (cm2 ):
0.83
1.29
I" Individual Fibers B/C-Bundles or Clumps
I+B/C-Airborne Structures Counted T-Individual Fibers Plus Estimated of Fibers in Bundles or Clumps
Number
-47-
0061
GI00061
APPENDIX II PHOTOMICROGRAPHS
1* (Plate 479) - Supply air sanple showing absence of dust and fibers in supply air (Nag. - 1000X).
2. (Plate 548) - Very long asbestos fibers associated in a loose cluster (Nag. - 2000X).
3. (Plate 549) - Typical asbestos fiber bundle showing splayed ends and snail fibril fragnents (Mag. - 2700X).
4. (Plate 555) -Typical asbestos elunp/bundle association showing random orientation of sone fibril. (Mag. - 50 0 0X ) .
5. (Plate 551) - A large cluster of individual fibers, large bundles, and clunps deposited as a single structure on filter (Mag. 3300X).
6 . (Plate 562) - Numerous asbestos fibers and bundle structures deposited in close proximity on filter (Mag 1300X).
7*
(Plate 553) - Typical small chrysotile fiber bundle deposited sihely-
(Mag - 2000X).
8 . (Plate 556) - Extre me ly large chrysotile bundle 15 to 25 um in diameter deposited on filter. (Mag - 1700X).
9. (Plate 552) - Asbestos fiber bundles with organic globular particulates adhering to surface (Mag - 6700X).
10. (Plate 563) - Large asbestos bundles deposited as a single structure on filter (Mag -1700X).
11. (Plate 560) (Mag - 1200X).
Large
asbestos fibers associated in a single cluster.
12. (Plate 560) - Large asbestos bundle and fibrils associated as a single structure. (Mag - 2000X). '
13. (Plate 557) - Typical heavy loading of asbestos structures on filter, (hag - 1000X).
14. (Plate 465) - Sample of bulk insulation material taken from a dryer. 15. Example EDAX spectrum from a dryer air sample.
-48-
C062
GI00062