PLAINTIFF'S EXHIBIT Department of Energy Savannah River Operations Office PQ Box A Aiken, South Carolina 29801 AUG 2 0 1979 Mr. Ruben Ridgeway Associate Staff Manager - Safety Southern Bell Telephone 1600 Hampton Street Columbia, SC `29201 Dear Mr. Ridgeway: Enclosed is a copy of the results of the Du Pont evaluation of exposure of Southern Bell Telephone (SBT) installers to airborne asbestos fibers generated from hand-operated drills. The test was conducted with guidance from an SBT representative on work techniques and load levels to simulate as close as possible actual conditions of drilling into asbestos containing wallboard (Transits). This evaluation meets the initial asbestos monitoring requirements of the Occupational Safety and Health Program at Department of Energy facilities. We recommend that a written procedure be issued by SBT to cover this situation for its Savannah River Plant operation. Drilling into asbestos containing wallboard should be. limited by the procedure to hand-operated equipment, and not higher than shoulder level. A provision for cleanup of the asbestos bearing waste with a HEPA-filtered vacuum cleaner or by wet sweeping into a labeled waste bag should be included. If you will provide a" copy of the procedure, we will review it and appropriately inform Du Pont. It should be noted that any change in work techniques or load levels which could affect airborne asbestos fiber concentrations will require additional evaluation. Your cooperation in this matter is appreciated. Sincerely, Enclosure CONFIDENT.',* * W. T. Thornton, Chief Health, Safety Fire Protection Branch Safety 5 Environment Division 004005 ns-Mliai LEVEL CAVE MAINTENANCE SHOP FOREMAN R. B. Geddlngs S. BELL REPRE. C. Caudill * NO LOCATION BKGRD AT 76' i Area at wall 16' 2 Left 38' shoulder 4 Barricade 38' 7 Area by 16' floor 2' high FLOWRATE 1.38 pm PUMP NO. 5 3 Neptune 7 25 1.95 10 3 Neptune 7 TOTAL VOL 104.88 48.0 CONCENTRATION DESCRIPTION 0.01 F/cc Before all the tests 7/16/79 ND Tests 1-3 76.0 n.u 48.0 o.io 0.06 0.14 Tests 1-6 clean-up Tests 1-6 f; clean-up Tests 4-6 Clearing 19' 3 Neptune 7 57.0 0.02 After tests Blank L ---- -- -- 0.05 F/Field Same lot as other filters NO. LOCATION 3 Right shoulder S Right shoulder 6 Right ' shoulder 8 Right : shoulder 9 Right shoulder 10 Right shoulder i AT FLOWRATE PUMP NO. TOTAL VOL CONCENTRATION DESCRIPTION 6' 1.95 pm 27 2* 1.95 27 11.7 t 3.9 0.11 -ND .Test 1 hand drill 8 holes Test 2 wheel drill 8 holes 2' 1.95 27 3.9 ND Test 3 brace 6bi` drill 8 holes ,S' 1.95 1pm 2 2' 1.95 27 9.75 3.90 0.14 ND test 4 hand drill 8 holes Test 5 wheel dril 8 holes 2' 1.95 27 3.90 ND Test 6 brace 5 bii drill 8 holes Tests 1-3 Tests 4-5 Tests 6 Standing 2 ft from wall Kneeling m ft from wall Kneeling 2 ft from wall CONFIDENTIAL 004006 Nomenclature AT * Sampling Time * * Minutes F/cc - Fibers longer than 5 micrometers per cubic centimeter of air tpm Liters Per Minute AVERAGE BREATHING ZONE CONCENTRATION . 0,.05 F/cc HIGHEST SAMPLE CONCENTRATION 0.14 F/cc TLV = 2 F/cc CONFIDENTIAL 004007