Document Ne56anbb6nq8aad5jagyG221y

190 _________ i_Chapter 9\-1945 Guide of the proper size and is affected by conditions beyond control, is to resort to mechanical draft. This can often be done at small, expense and the arrangement can be such that the fan or blower need be operated only when conditions are bad. Two or more chimneys, either large or small, should never.be connected together especially near the bottom. Hot gases in an inverted U-tube thus formed will be in unstable equilibrium. Cold air will descend through one such chimney, from the top, and drive the hot gases out of the other and ^thus annul the draft. More than one device can be served by one chimney.. Batteries of boilers are commonly connected to a single chimney in power plants. However, if two or more chimneys are used, each chimney should be used separately for part of the boilers, and not connected in manifold with another chimney, in order to avoid the difficulty described previously. In domestic installations it is sometimes, necessary to serve a space heater or cooking stove and a water heater with the same chimney flue. This is not desirable, especially for low chimneys, since doors left open on one device while it is un-fired will tend to annul the draft on another device. Gas burning devices, with their draft hoods and lack of draft dampers, are especially bad in this respect. The traditional method of avoiding this with brick chimneys has been to construct multiple-flue chimneys, so that each fuel-burning device could be served by a separate opening. If two devices must be served by one flue-opening in a chimney, their connections to the chimneys should not be located opposite each other. The connection from the larger, device should be reasonably low down and that from the smaller, up near the ceiling, so that each device can be serviced as well as possible, regardless of the treatment of the other. Excessive height in a chimney does no harm but means for controlling ' the draft are more than ordinarily essential if the chimney is too large in capacity. Coal-burning devices often have air leaks around the fire-box and the draft doors sometimes fit poorly so that the fire cannot be con trolled at a low .rate. Perhaps the simplest remedy for such cases is the barometric damper which admits air into the flue pipe and thus reduces the draft. Directions for building chimneys for fireplaces are contained in Depart ment of Agriculture Farmers' Bulletin No. 1230. It is considered bad practice to connect any heating device to a fireplace flue unless the fireplace is effectively sealed. ! if: CHAPTER 10 _Automatic Juei (Burning. ^Ic^uipment Classification of Stokers, Combustion Process and Adjust ments, Furnace Design, Classification of Oil Burners, Combus tion Chamber Design, Classification of Gas-Fired Appliances AUTOMATIC mechanical equipment for the combustion of solid, liquid, and gaseous fuels is considered in this chapter. MECHANICAL STOKERS A mechanical stoker is a device that feeds a solid fuel into a combustion chamber, provides a supply of air for burning the fuel under automatic control and, in some cases, incorporates a means of removing the ash and refuse of combustion automatically. Coal can be burned more efficiently by a mechanical stoker than by hand firing because the stoker provides a uniform rate of fuel feed, better distribution in the fuel bed and positive control of the air supplied for combustion. CLASSIFICATION OF STOKERS ACCORDING TO CAPACITY Stokers may be classified according to their coal feeding rates. The following classification has been made by the U. S. Department of Com merce, in cooperation with the Stoker Manufacturers Association. Class 1. Capacity under-61 lb of coal per hour. Class 2. Capacity 61 to 100 lb of coal per hour. , Class 3. Capacity 101 to 300 lb of coal per hour. Class 4: Capacity 300 to 1200 lb of coal per hour. Class 5.- Capacity 1200 lb of coal per hour and over. Class 1 Stokers These stokers are used primarily for home heating and are designed for quiet, automatic operation. Simple, trouble-free construction and attractive appearance ar$ desirable characteristics of these small units. A common stoker in this class (Fig. 1) consists essentially of a coal hopper, a screw for conveying the coal from the hopper to the retort, a fan which supplies the air for combustion, a transmission for driving the. coal feed worm, and an electric motor for supplying power for coal feed and air supply. Air for combustion is admitted to the fuel through tuyeres at the top of the retort, and in this class, the retort maybe either round or rectan gular. Stokers in this class are made for burning anthracite, bituminous,; semi-bituminous, and lignite coals, and coke.' The U. S. Department of Commerce has issued commercial standards for household anthracite stokers1. Units are available in either the hopper type, as shown in Fig. 1 or in the bin-feed type as shown in Figs. 2 and 3. Sortie stokers, particularly those designed for use with anthracite automatically remove ash from the ash pit and deposit it in an ash receptacle as shown in Fig. 3. Most of the bituminous models, however, require removal of the ash from the fuel bed after it is fused into.a clinker. Domestic Burners for Pennsylvania Anthracite (Underfeed Type), (U. S. Department of Commerce, national Bureau of Standards, Commercial Standard No. CS4S-40).