Document Ne4YvqoEeJ2j9zbrxa8Y2aD6g
MoBiOTto
FROM J. H. Orem - Galt Labs - 1730
4 N AM E -- t- OC AT ION -- RHONE I
BATE SUBJECT REFERENCE
TO
June 22, 1978
cc` .
THIOKOL CHEMICAL CORP. CUSTOMER CALL 6-14-78 S. F. Hastay CR 6-14-78
J. A. Cannon
S. F. Hastay - 1940
T. G. Iversen - B3NC
C. N. Keeney
A. W. Morgan
J. T. Renshaw
.
P. Stordeur -5045
J. VanOudenhove - 5040
N. W. Touchette
W. T. Vreeland - B3NC
J. S. Williams - 1940
FOR THIOKOL:
FOR MONSANTO:
Tony Castor, Marketing Mgr. Ted Grobelny, Marketing Program Mgr. Mel Schulman, Mgr. Tech.-Service
S. F. Hastay J. H. Orem
XA-1014A:
Status of the project for low durometer urethane rollers was reviewed by Messrs. Castor and Grobelny. They are rapidly approaching the decision point. Based upon their lab's work, XA-1014A is the technically superior product. One drum is required for a trial at a major customer.
Two additional one quart samples will be sent to S. F. Hastay. One is re quired for continued work in the low durometer urethane program; the other is for use in a new polyether urethane project.
Polysulfide Sealants For Insulated Windows:
Santicizer 278:
'
1. Mr. Schulman recently returned from a 2 week technical service trip to Europe. He found many of these sealants being made with Santicizer 160. No fogging concerns were raised. This S-160 use was found all over Western Europe including Italy and the south of France.
2. Based upon their laboratory evaluation results, today, Thiokol would recommend the use of chlorinated paraffins over Santicizer 278. In fact, there is a large volume being used; refer to my report on PRC.
3. Wet UV testing is conducted by immersing simulated window units (small lab size) under water, temperature is 170-180F, and exposing to UV light. When the sealant parts, the bond at the glass-sealant interface begins to deteriorate. Thiokol will place these units under a vacuum and look for deflection. If the seal is good, the "unit will deflect.
' 0623464
HARTOLDMONOOQ4724
2.
Suggested formulation for our work:
LP 2 or 32 Plasticizer Hakuenka Epoxy silane Catalyst*
100 30 30
3-2-1 15
(* essentially 1:1 S-278/Mn02 "D" grade)
The three levels of epoxy silane were suggested to permit a determination of the plasticizer's contribution to adhesion.
5. They inquired regarding the moisture pick-up of Santicizer 278 vis-a-vis CP's at 100% RH/100F.
Chlorinated Paraffins:
1. use in the U.S is known by European sealant producers, and they are working with them in development programs.
2. outperform S-278 in MVT and wet UV. CP's are more hydrophobic.
3. are good tackifiers.
4. without calcium carbonate fillers will never cure; CaCO, is needed to absorb the HC1.
5. cannot be used to make a stable Mn02 paste. Pastes with CP's lose activity.
6. as temperatures decrease, are more difficult to pump than is S-278. This was mentioned to Mr. Schulman by several European manufacturers of polysulfide sealants.
General:
In production of these sealants, the U.S. uses much more solvent than do European manufacturers. Europeans are reluctant to use solvents.
0623465
HARTOLDMONOOQ4725