Document Ne4Qo2eGQmD8vQ7rVdRmQ5XMR
FILE NAME Caterpillar CAT DATE 1974 Aug 29
DOC CAT060
DOCUMENT DESCRIPTION Memo RE Air Sampling Conducted at the Milwaukee
Plant
A CATERPILlar
PEORIA
tractor
co
OFFICE | DEPARTMENT [ ATTENTION
DATE
PLANT OR OFFICE
August 29 1974
Milwaukee
DEPT
ATTN
Planning
M. Nordling
DESTROY
FILE UNTIL DATE
CC
G. W. Grawey M.D.
R. R. Hoffman
J. C. Myers E. J. Sabljack M.D.
D. Stollenwerk
Subject
Results of Air Sampling Conducted
in the Milwaukee Plant
This report covers the results and evaluation of air samples collected at brake band assembly and hard facing operations during late June 1974
I. Pipe Layer Brake Band Assembly
Four samples were taken for determination of airborne asbestos These samples covered one hour of operation at an above normal
The results are tabulated below
fiber count work pace
Sample #
A
Date
6-14-74
Air Vol 29.25 liters
Fibers Found 24,000
Asbestos
Fibers cc air
0.82
B
6-14-74
29.25 liters .
24,300
C
6-14-74
29.25 Ilters
22,800
0.83 0.78
D
6-14-74
29.25 liters
21.600
0.74
Note 1 - total fiber count represents those greater than 5 micrometers ia lengths as specified in OSHA 1910.93a
Note 2 - The present OSHA limit is
Effective July 1 1976 this limit
centimeter of air
5 fibers per cubic will be reduced to
centimeter of air 2 fibers per cubic
.
.
Results of this recent air monitoring indicate that there is no excessive asbestos fiber exposure at present With any increased production rate and
the absence of exhaust ventilation control this operation should be critically reviewed in light of the reduced exposure limit effective in July 1976. The results reported in this study are about 50 percent of the 1976 allowable
limit
PLAINTIFF'S
tabbles
EXHIBIT
01-896-80505.2 01-896-80505.2 01-896-80505.2
CAT
forotpe
1030770 013
M. Nordling
August 29 1974
Since there is no local and the no effect level
following action should
exhaust ventilation in the brake of asbestos fibers in air is not be taken
band assembly area established the
1. Newly opened boxes of brake bands should be vacuumed as parts are
removed
.
2 Any dust generated at drilling and countersinking should be vacuumed up and not left to be redispersed
.3 Bench tops in the work area should be kept clean by periodic vacuuming
4 Any waste scrap or other debris should be sealed in plastic bags for proper disposal as per OSHA 1910.93A
5 Plant Medical Department review of OSHA regulations 1910.93a on employee
examinations and records
6 A recheck of asbestos fiber concentration should be made in six months
I believe a small vacuum cleaner could be used effectively in the areas mentioned in Items 1 2 and 3
REDACTED
103077110307 1
013
M. Nordling
;
August 29 1974
Please keep us informed of any action taken pertaining to this report
REKinser
Industrial Hygiene Engineer
Ext 5315 jw
R.E. R.E. Kinser
1030772
013