Document NYjEjdrmM86mDJL4Jb0oDZ3V
Et hyl Gasol ine Corporat ion
Chemical Resear ch Labor at or y 160og S West Eight Mil e Road
De t r o i t , Mi c h ig a n
December 14, 1940
Dr. Robert A. Kehoe College of Medicine University of Cincinnati Cincinnati, Ohio Dear Bob Please find herewith a copy of Dr. Beatty's memorandum dated December 13 covering the operation of the army gasoline stove. The two significant observations to date are:
(a) One-third of the lead input goes off with the combustion products, setae of it settling on the bottom of the heated kettle. (2) The trouble with gumin the heated tube, encountered by the Army, has not yet been observed. This coming week we shall experiment vdth the triple filter, and we are also expecting to hear from the Army about the gumming up. We shall be very glad, if you wish, to send Mr. Heal to Cincinnati to help your men familiarize themselves vdth the operation and idiosyncrasies of the equipment.
GC:JH Enel. CC Dr. Edgar
Mr. Gay
000354!
/ / /
MEMORANDUM Test of U.S. Amy Gasoline Stove
December 13, 1940
A complete fire unit of a U.S. Army gasoline.Field Range, together Y.ith spare filters and cleaning tools, was received through Mr. E. Oay, and has been installed in an outside shed at the Chemical Laboratory. A series of five runs has been made by Mr. H. R. Heal on three different fuels: Red Crown Base, 'the S.0.I7.J. Fuel B (6S%olefine), and a 100%Michigan eraclced (3 years old, very high gum), each containing 3 cc. lead per gallon in 70-45 Fluid.
From the viewpoint of lead removal and deposits, the principal feature of the operation is that, after the flame has been started and maintained by hand for a time, it then heats a "generator" in which the fuel is fed under pressure, completely vaporized, partially cracked, and passed through a filter to remove the lead; from this generator, the fuel vapor goes to the "flame valve" where its rate of flow is controlled and it is mixed with air and fed to the burner proper. The operating instructions call for replacement of the filter every four hours, and cleaning the connecting tube, flame valve, and burner surface with scraping tools and (if required) a gum solvent every 12 hours.
Our tests were planned to determine: (1) The percentage of the lead input retained by the filter disc. (2) The location and amount of lead deposits elsewhere, and of gum. (3) The performance of the unit as a whole:
(a) when cleaned as per instructions, and (b) when allowed to operate without cleaning (except for
change of filter each 4 hrs.), until faulty operation occurred at some point. The results obtained may be summarized as follov/s: (l) Lead retained by filter. - About 70%of the lead input is retained by the stove, practically all in the filter and its case. Tho data are: Run 2, 6.75 hrs., 1 filter used, about 68%of the lead recovered, 5%in the filter case, 25%in the outlet half side of the filter, and 37%in the inlet half side; Run 3, 12 hrs., 3 flit erf .used, 66%of the lead recovered* Run 4, 15 hrs., 4 filters used, 77%of the lead recovered; Run 5, analysis in progress.
HE 0003542
/ 2.
(2) Other lead deposits. - In the flame valve jet, about 10 or 20 mg. lead is deposited every 4 hrs., and this Is sufficient to require cleaning the valve about every 12 hrs. On the tubing and burner surfaces, the lead deposited is small, readily removed, and not troublesome. On the bottom of a kettle, containing warmcrater, which was placed directly over the burner flame, lead was deposited at the rate of 50 mg. every 4 hrs. (2 Runs, which checked).
GumDeposits. - Yery little gum, about 10 mg. every 4 hrs., was deposited in the connecting tubing using the Red Crown or S.O.N.J. fuels; the Michigan fuel will show large deposits in tubes and flame valve (data not yet available).
(3) "When the filters are changed every 4 hrs. and the various parts are cleaned every 12 hrs. following the specified procedures, there are no troubles resulting from lead or gum deposits,except that, first: the flame valve may require cleaning before 12 hrs., especially with a high-gum fuel, and second: the openings into the filter case may not be adequately cleaned by the specified procedure (an ammonium acetate extraction of the case following the routine cleaning dissolved 546 mg. lead ).
.
Numerous mechanical difficulties were encountered which could not be directly ascribed to the deposits: the most frequent were leaks at the filter case and the valves.
Summary. - The operation is reasonably satisfactory, except that only 70% of the lead is retained; the change of filters and cleaning operations are not unduly difficult and give satisfactory results, but cannot be neglected without running into trouble.
It is planned to make a new case to hold 3 filters together, and test the lead removal.
HAB:JH
H. A. Beatty 12-13-40
0009543