Document NVw8B9db8wp4xjZn6Q7VDewE

PLAINTIFF'S EXHIBIT PORM P927 CER1AIMTEED description: TECHNICAL SPECIFICATIONS CT-378 SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION T.C.O. REF. NO. 2 SUPERSEDES: SPECIFICATION NO: 528 PAGE NO.: DATE OF ISSUE: 1 March 30, 1966 NOV 2 1976 CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling A. General 1.0 Description The CERTA-SPACER band herein described consists of a synthetic compound that is plastic in nature. Plastic is defined as a material that deforms and remains deformed after reduction of the deforming stress. The synthetic compound shall be properly compounded to meet the requirements of this specification. 2.0 Design The CERTA-SPACER bands shall be rectangular in cross section and shall be manufactured to the shape and dimensions as shown in Figures I, II, and III of this specification. 3.0 Color The bands shall be gray in color. The gray color shall be similar to that of the A/C Pipe. The color shall be approved by the Materials Laboratory Supervisor, P&PG. Use The CERTA-SPACER bands are intended for use with Asbestos-Cement Pressure 4", 18" 20", 24" and Gravity Sewer Pipe and Coupling as manufactured by P&PG of CertainTeed Corporation, as an aid in keeping the ends of the assembled pipe separated to allow for axial expansion. Lot Size For sampling and inspection purposes, a lot shall be defined as the quantity of CERTA-SPACER bands shipped on one order, received at one time, and identified by a code number. D. Requirements 1.0 Special CTD015051. All compounds shall be approved by the Materials Laboratory Supervisor of P&PG in writing and referenced by the Vendor Compound Number. After PREPAREO BY: M'H APPROVED BV: Q CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL FORM P927 CER1WWTIED description: TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: L A/C Standard Purchasing Specification CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION T.C.O. REF. NO. 2 SUPERSEDES: SPECIFICATION NO: 528 PAGE NO.: 2 DATE OF ISSUE: March 30, 1966 NOV 2 1976 CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling approval no changes in compounds shall be made without authorization, in writing, from the Materials Laboratory Supervisor of P&PG and a new vendor reference number assigned. The manufacturer shall notify the Purchasing Department and the Materials Laboratory Supervisor of P&PG when such an authorized change is actually placed in effect. 2.0 Manufacturers Inspection and Control Data The manufacturer shall perform such inspection duties so that all defective bands are removed before shipment. 3.0 Appearance The surface and body of the CERTA-SPACER band shall be free from pitting, cracks, blisters, porosity and air pockets. A slight flash at the splice is allowed. 4.0 Splice The splice shall be properly joined and sufficiently strong to withstand 50% elongation without separation or pulling. 5.0 Dimensions The dimensions shall be in accordance with the requirements as shown in Figures I, II, and III of this specification. 6.0 Physical Characteristics The physical characteristics shall be in accordance with the requirements as shown in Table A of this specification. Test Methods 1.0 Dimensional and Appearance (a) Appearance Visual examination. (b) Splice CTD015052 Visual examination when specimen is under 50% elongation. The entire band shall be used in this test. All specimens tested must pass. At PREPARED BY: MU APPROVED by: R ft D MFG. SALES |.E Cjfc CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL FORM P927 CERIAIHTtED description: TECHNICAL SPECIFICATIONS SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION T.C.O. REF. NO. 2 SUPERSEDES: SPECIFICATION NO: 528 PAGE NO.: 3 OATE OF ISSUE: March 30, 1966 NOV 2 1976 CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling least three bands per lot shall be tested. (c) Outside Diameter The outside diameter shall be tested by cutting the band at the splice and measuring the cut length. At least three specimens per lot shall be tested; these specimens shall not be the same specimens used to test the splice. All samples tested must meet the requirements as shown in this specification. (d) Thickness and Height A dial micrometer accurate to 0.001 inch shall be used. Each band measured shall be measured at 4 points 90 apart. The average of the readings must be within specification limits. 2.0 Physical Characteristics (a) Tensile Strength, Elongation, & Modulus at 100% Elongation Samples for tensile strength, elongation and modulus shall be taken from the band itself. The entire cross section of the band shall be used. The samples shall be six (6) inches long. Three bands per lot shall be tested. Test to be performed in Materials Laboratory of P&PG. The average results must meet specification requirements. (b) Hardness The test shall be made by means of the Shore A2 Durometer on the finished bands themselves. Five bands in each lot shall be tested. Two readings shall be made on each band and the median reading recorded. All tests are to be carried out at a temperature of 75F + 5. (c) Ozone Three specimens 10" + 1/8" shall be cut from each end. Form the speci mens into a loop by putting the two marks together and tying securely with wire at the marks. Slide the completed loop over the 2" diameter mandrel. After specimens are mounted, allow them to rest for a minimum of 48 hours at room temperature in a relatively ozone free atmosphere. Then expose to 50 pphm of ozone at 100F for 48 hours. CTD015053 PREPARED BY: jsii APPROVED BY: CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL TECHNICAL SPECIFICATIONS CertairileedEI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. 4 SPECIFICATION NO: 528 PAOE NO.: 4 SUPERSEDES: June 10, 1977 DATE OF ISSUE: JAN 0 1980 description: CERTA-SPACER Bands For Use With CT Pressure And Gravity Sewer Pipe And Coupling The degree of cracking shall be determined in accordance with ASTM Test D 1171 (Latest Edition), Figure 3. The average test results of th specimens tested shall comply with the requirements. (d) Low Temperature Flexibility Five (5) specimens shall be prepared for the Low Temperature Flexibility Test in accordance with ASTM Specification D 746 (Latest Edition) Test for IiritLlcness Tar.perature of Plastics. Procedure B under Routine Inspection and Acceptance shall be followed. (e) Aging Test Five (5) specimens shall be prepared from the finished bands. They shall he cut in six inch lengths and placed in a circulating air oven for 166 hours +2 hours at 158F + 21'. Upon removal, allow to cool to room temperature (4 hours), Perform tensile, elongation, and hardness tests on the aged samples. (f) Packaging and Marking CERTA-SPACER bands shall be shipped in the size cartons as shown below. The carton shall be a standard color and 275 pound test regular slotted carton, the flute to run parallel to the height. All cartons are to be sealed using reinforced tape or stapled. The markings on the carton may be either Vendor's label or stencil. The color of the marking shall be black. All cartons must show the size, CERTA-SPACER hands, the number of bands in the carton, and P&PG's order number. CTD015054 PREPARED BY: /-tT APPROVED BT: R AO 02-10-0023 (P9?7) 12/76 CONFIDENTIAL DOCUMENT - NOT MFO 0 SALES JA I.E. Qtte OTHERS TECHNICAL SPECIFICATIONS CertairileedEI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PA0E NO.: 4 supersedes: November 2, 528 1976 5 DATE OF ISSUE: JAN 9 1980 DESCRIPTION: CERTA-SPACER Bands For Use With C T Pressure And Gravity Sewer Pipe And Coupling Size 3 4 6 8 10 12 14 16 18 20 24 Length 15 15 15 45 45 45 36 36 36 36 36 PRELIMINARY Carton Size Inside Dimensions, Inches Wid th Height 10 10 10 8 8 .8 12 12 12 12 12 .. 10 10 10 8 8 8 12 12 12 12 12 No. of Bands Per Carton 500 500 500 500 500 500 500 500 250 250 250 CTD015055 PREPARED BY: /K APPROVED BY: >4>> R *D MFQ. SALES J.fiA I.E. 0*b 02-10-002 3 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZEd'pERBONNEL OTHERS FORM P927 CERTNNTRD DESCRIPTION: TECHNICAL SPECIFICATIONS SPECIFICATIONS classification: A/C Standard Purchasing Specification CERTAIN-TEED PROOUCTS CORPORATION PIPE DIVISION T.C.O. REF. NO. SPECIFICATION NO: SUPERSEDES: 528 March 30, 1966 DATE OF ISSUE: NOV 2 1976 CERTA SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling (g) Acceptance and Rejection P&PG reserves the right to reject any lot or lots found not conforming to the requirements of this specification. Such rejection or acceptance of a lot, lots, or portions thereof shall not be limited to the time of delivery but shall be accomplished within thirty (30) days from receipt date. In the event of rejection, the vendor shall be immediately advised and the reason for the rejection explained. The vendor shall be given the opportunity to inspect rejected material on representative samples of the rejected material. The vendor must express his desire to inspect rejected material within seven days after notification of the rejections and the physical inspection of rejected material must be performed within 30 days after the notification of rejections. PREPARED BY: CTDO15056 APPROVED BY: D MFG. SALES I.E. OTHERS CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL FORM P927 CER1AINTIED description: TECHNICAL SPECIFICATIONS SPECIFICATIONS CLAS SIFICATION: CERTAIN-TEED PRODUCTS CORPORATION PIPE DIVISION A/C Standard Purchasing Sjjecification T.C.O. REF. NO. SPECIFICATION NO PAOE NO: 2 528 7 SUPERSEDES: DATE OF ISSUE: March 30, 1966 NOV 2 1976 CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Couplings FIGURE I 3 THRU 12 Size 3" 4" 5" 6" 8" 10" 12" Class All All All All All All All O.D. Inches 3.24 4.02 5.00 5.70 7.45 9.20 10.95 Cut Length Inches 9.67 12.10 15.37 17.35 22.85 28.40 34.00 Cut Lengt Tol. Inct + .125 + .125 + .125 + .125 + .125 + .125 + .125 PREPARED BY: CTD015057 | APPROVED BY: R D MFC. SALES I.E. OTHERS | CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL TECHNICAL SPECIFICATIONS CertairileedEI SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO..' CertainTeed Corporation Pipe and Plastics Group 3 528 SUPERSEDES: November 2 , 1976 8 DATE OF ISSUE: JUN 1 0 1977 DESCRIPTION: CERTA-SPACER Bands for use with CT Pressure and Gravity Sewer Pipe and Couplings FIGURE I 14"$ 16 Size 14" 15" 16" Class All All All O.D. Inches 12.80 13.70 14.50 Cut Length Inches 39.60 42.40 45.00 Cut Length Tol. Inches + .125 + .125 + .125 CTD015058 PREPARED BY: 8r: R &D MFG. SALES I.E. OTHERS 02-10-0023 (P927) * (MS 12/76 CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL TECHNICAL SPECIFICATIONS CertairileedEi CerlainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: 3 528 9 November 2, 1976 DATE OF ISSUE: JUH 1 0 1977 DESCRIPTION: CERTA-SPACER Bands for use with CT Pressure and Gravity Sewer Pipe and Coupling FIGURE M 18 THRU 24 V .450 Size 18" 20" 21" 24" Class All All All All Inches 16.53 18.30 19.00 21.95 Cut Length Inches 51.25 56.75 58.80 68.10 Cut Length Tol. Inches + .125 . +.125 + . 125 + .125 CTD015059 PREPARED BY: 0)1 02-10-002 3 (pqg71 dftf' APPROVED BY: R *O MFO. SALES I.E. OTHERS Is Ote' 12/76 confidential document - wot to be distributed to unauthopitp PERSONNEL TECHNICAL SPECIFICATIONS CertairileedEI SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C.O. REF. NO. SPECIFICATION NO: PAGE NO.: CertainTeed Corporation Pipe and Plastics Group 3 SUPERSEDES: November 2 528 1976 10 DATE OF ISSUE: JUN 1 0 1977 MKKIPTIOK: CERTA-SPACER Bands for use with CT Pressure and Gravity Sewer Pipe and Coupling TABLE A Physical Characteristics Property Original Tensile, psi Min. Average Min. Single Sample Aged Tensile, 166 hrs. + 2 158F + 2; 7o decrease from orig. Original Elongation at Rupture, per cent Min. Average Min. Single Sample Aged Elongation, 166 hrs. + 2 158F + 2; % decrease from orig. Hardness, Shore Durometer (Type A or A2) Aged Hardness, 166 hrs. + 2 158F + 2; change from orig. points Max. Modulus, 1007. elongation, psi Min. Low Temperature flexibility, -25C Ozone Resistance, 100F, 48 hrs. 50 pphm Ozone, Max. Rating 1400 1300 10 250 200 15 80+5 5 750 No Cracks PREPARED BY: 0 CTD015060 APPROVED BY: R ft D MFG. SALES I.E. OTHERS t Octe PERSONNEL TECHNICAL SPECIFICATIONS CertairileedEI CertainTeed Corporation Pipe and Plastics Group SPECIFICATIONS CLASSIFICATION: A/C Standard Purchasing Specification T.C-O- REP. NO. 3 SPECIFICATION NO: 528 Addendum PAGE NO.: 1 SUPERSEDES: OATE OF ISSUE: JUN 1 0 1977 description: Certa-Spacer Bands for Use with CT Pressure and Gravity Sewer Pipe and Couplings ' NOT TO BE DISTRIBUTED TO VENDORS i Approved Vendors: Pawling Rubber Company Pawling, New York 12564 Ktrkhill Rubber Company 300 East Cypress Street Brea, California 92621 i I PRCPARED BY: APPROVED BY: >4) CTD015061 R ft D MFC SALES I.E. OTHERS 0<tS