Document NVw8B9db8wp4xjZn6Q7VDewE
PLAINTIFF'S EXHIBIT
PORM P927
CER1AIMTEED
description:
TECHNICAL SPECIFICATIONS
CT-378
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
CERTAIN-TEED PRODUCTS CORPORATION
PIPE DIVISION
T.C.O. REF. NO.
2
SUPERSEDES:
SPECIFICATION NO:
528
PAGE NO.:
DATE OF ISSUE:
1
March 30, 1966
NOV 2 1976
CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling
A. General
1.0 Description
The CERTA-SPACER band herein described consists of a synthetic compound that is plastic in nature. Plastic is defined as a material that deforms and remains deformed after reduction of the deforming stress. The synthetic compound shall be properly compounded to meet the requirements of this specification.
2.0 Design
The CERTA-SPACER bands shall be rectangular in cross section and shall be manufactured to the shape and dimensions as shown in Figures I, II, and III of this specification.
3.0 Color
The bands shall be gray in color. The gray color shall be similar to that of the A/C Pipe. The color shall be approved by the Materials Laboratory Supervisor, P&PG.
Use
The CERTA-SPACER bands are intended for use with Asbestos-Cement Pressure 4", 18" 20", 24" and Gravity Sewer Pipe and Coupling as manufactured by P&PG of CertainTeed Corporation, as an aid in keeping the ends of the assembled pipe separated to allow for axial expansion.
Lot Size
For sampling and inspection purposes, a lot shall be defined as the quantity of CERTA-SPACER bands shipped on one order, received at one time, and identified by a code number.
D. Requirements 1.0 Special
CTD015051.
All compounds shall be approved by the Materials Laboratory Supervisor of P&PG in writing and referenced by the Vendor Compound Number. After
PREPAREO BY:
M'H
APPROVED BV:
Q
CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
FORM P927
CER1WWTIED
description:
TECHNICAL SPECIFICATIONS
SPECIFICATIONS CLASSIFICATION: L
A/C Standard Purchasing Specification
CERTAIN-TEED PRODUCTS CORPORATION
PIPE DIVISION
T.C.O. REF. NO. 2
SUPERSEDES:
SPECIFICATION NO:
528
PAGE NO.:
2
DATE OF ISSUE:
March 30, 1966
NOV 2 1976
CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling
approval no changes in compounds shall be made without authorization, in writing, from the Materials Laboratory Supervisor of P&PG and a new vendor reference number assigned. The manufacturer shall notify the Purchasing Department and the Materials Laboratory Supervisor of P&PG when such an authorized change is actually placed in effect.
2.0 Manufacturers Inspection and Control Data
The manufacturer shall perform such inspection duties so that all defective bands are removed before shipment.
3.0 Appearance
The surface and body of the CERTA-SPACER band shall be free from pitting, cracks, blisters, porosity and air pockets. A slight flash at the splice is allowed.
4.0 Splice
The splice shall be properly joined and sufficiently strong to withstand 50% elongation without separation or pulling.
5.0 Dimensions
The dimensions shall be in accordance with the requirements as shown in Figures I, II, and III of this specification.
6.0 Physical Characteristics
The physical characteristics shall be in accordance with the requirements as shown in Table A of this specification.
Test Methods
1.0 Dimensional and Appearance
(a) Appearance
Visual examination. (b) Splice
CTD015052
Visual examination when specimen is under 50% elongation. The entire band shall be used in this test. All specimens tested must pass. At
PREPARED BY:
MU
APPROVED by:
R ft D
MFG.
SALES
|.E
Cjfc
CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
FORM P927
CERIAIHTtED
description:
TECHNICAL SPECIFICATIONS
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
CERTAIN-TEED PRODUCTS CORPORATION
PIPE DIVISION
T.C.O. REF. NO.
2
SUPERSEDES:
SPECIFICATION NO:
528
PAGE NO.:
3
OATE OF ISSUE:
March 30, 1966
NOV 2 1976
CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling
least three bands per lot shall be tested.
(c) Outside Diameter
The outside diameter shall be tested by cutting the band at the splice and measuring the cut length. At least three specimens per lot shall be tested; these specimens shall not be the same specimens used to test the splice. All samples tested must meet the requirements as shown in this specification.
(d) Thickness and Height
A dial micrometer accurate to 0.001 inch shall be used. Each band measured shall be measured at 4 points 90 apart. The average of the readings must be within specification limits.
2.0 Physical Characteristics
(a) Tensile Strength, Elongation, & Modulus at 100% Elongation
Samples for tensile strength, elongation and modulus shall be taken from the band itself. The entire cross section of the band shall be used. The samples shall be six (6) inches long. Three bands per lot shall be tested. Test to be performed in Materials Laboratory of P&PG. The average results must meet specification requirements.
(b) Hardness
The test shall be made by means of the Shore A2 Durometer on the finished bands themselves. Five bands in each lot shall be tested. Two readings shall be made on each band and the median reading recorded. All tests are to be carried out at a temperature of 75F + 5.
(c) Ozone
Three specimens 10" + 1/8" shall be cut from each end. Form the speci mens into a loop by putting the two marks together and tying securely with wire at the marks. Slide the completed loop over the 2" diameter mandrel. After specimens are mounted, allow them to rest for a minimum of 48 hours at room temperature in a relatively ozone free atmosphere. Then expose to 50 pphm of ozone at 100F for 48 hours.
CTD015053
PREPARED BY:
jsii
APPROVED BY: CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
TECHNICAL SPECIFICATIONS
CertairileedEI
CertainTeed Corporation Pipe and Plastics Group
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
T.C.O. REF. NO.
4
SPECIFICATION NO:
528
PAOE NO.:
4
SUPERSEDES:
June 10, 1977
DATE OF ISSUE:
JAN 0 1980
description:
CERTA-SPACER Bands For Use With CT Pressure And Gravity Sewer Pipe And Coupling
The degree of cracking shall be determined in accordance with ASTM Test D 1171 (Latest Edition), Figure 3. The average test results of th specimens tested shall comply with the requirements.
(d) Low Temperature Flexibility
Five (5) specimens shall be prepared for the Low Temperature Flexibility Test in accordance with ASTM Specification D 746 (Latest Edition) Test for IiritLlcness Tar.perature of Plastics. Procedure B under Routine Inspection and Acceptance shall be followed.
(e) Aging Test
Five (5) specimens shall be prepared from the finished bands. They shall he cut in six inch lengths and placed in a circulating air oven for 166 hours +2 hours at 158F + 21'. Upon removal, allow to cool to room temperature (4 hours), Perform tensile, elongation, and hardness tests on the aged samples.
(f) Packaging and Marking
CERTA-SPACER bands shall be shipped in the size cartons as shown below. The carton shall be a standard color and 275 pound test regular slotted carton, the flute to run parallel to the height. All cartons are to be sealed using reinforced tape or stapled.
The markings on the carton may be either Vendor's label or stencil. The color of the marking shall be black. All cartons must show the size, CERTA-SPACER hands, the number of bands in the carton, and P&PG's order number.
CTD015054
PREPARED BY:
/-tT
APPROVED BT:
R AO
02-10-0023 (P9?7) 12/76 CONFIDENTIAL DOCUMENT - NOT
MFO
0
SALES
JA
I.E.
Qtte
OTHERS
TECHNICAL SPECIFICATIONS
CertairileedEI
CertainTeed Corporation Pipe and Plastics Group
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PA0E NO.:
4
supersedes:
November 2,
528 1976
5
DATE OF ISSUE:
JAN 9 1980
DESCRIPTION:
CERTA-SPACER Bands For Use With C T Pressure And Gravity Sewer Pipe And Coupling
Size
3 4 6 8 10 12 14 16 18 20 24
Length
15 15 15 45 45 45 36 36 36 36 36
PRELIMINARY
Carton Size Inside Dimensions, Inches
Wid th
Height
10 10 10
8 8 .8 12 12 12 12 12
.. 10 10 10 8 8 8 12 12 12 12 12
No. of Bands Per Carton
500 500 500 500 500 500 500 500 250 250 250
CTD015055
PREPARED BY:
/K
APPROVED BY:
>4>>
R *D
MFQ.
SALES
J.fiA
I.E.
0*b
02-10-002 3 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZEd'pERBONNEL
OTHERS
FORM P927
CERTNNTRD
DESCRIPTION:
TECHNICAL SPECIFICATIONS
SPECIFICATIONS classification:
A/C Standard Purchasing Specification
CERTAIN-TEED PROOUCTS CORPORATION
PIPE DIVISION
T.C.O. REF. NO.
SPECIFICATION NO:
SUPERSEDES:
528
March 30, 1966
DATE OF ISSUE:
NOV 2 1976
CERTA SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Coupling
(g) Acceptance and Rejection
P&PG reserves the right to reject any lot or lots found not conforming to the requirements of this specification. Such rejection or acceptance of a lot, lots, or portions thereof shall not be limited to the time of delivery but shall be accomplished within thirty (30) days from receipt date. In the event of rejection, the vendor shall be immediately advised and the reason for the rejection explained. The vendor shall be given the opportunity to inspect rejected material on representative samples of the rejected material. The vendor must express his desire to inspect rejected material within seven days after notification of the rejections and the physical inspection of rejected material must be performed within 30 days after the notification of rejections.
PREPARED BY:
CTDO15056
APPROVED BY:
D MFG.
SALES
I.E.
OTHERS
CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
FORM P927
CER1AINTIED
description:
TECHNICAL SPECIFICATIONS
SPECIFICATIONS CLAS SIFICATION:
CERTAIN-TEED PRODUCTS CORPORATION
PIPE DIVISION
A/C Standard Purchasing Sjjecification
T.C.O. REF. NO.
SPECIFICATION NO
PAOE NO:
2 528
7
SUPERSEDES:
DATE OF ISSUE:
March 30, 1966
NOV 2 1976
CERTA-SPACER Bands for use with CPC Pressure and Gravity Sewer Pipe and Couplings
FIGURE I
3 THRU 12
Size
3" 4" 5" 6" 8" 10" 12"
Class
All All All All All All All
O.D. Inches
3.24 4.02 5.00 5.70 7.45 9.20 10.95
Cut Length Inches
9.67 12.10 15.37 17.35 22.85 28.40 34.00
Cut Lengt Tol. Inct
+ .125 + .125 + .125 + .125 + .125 + .125 + .125
PREPARED BY:
CTD015057
| APPROVED BY:
R D
MFC.
SALES
I.E.
OTHERS
|
CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
TECHNICAL SPECIFICATIONS
CertairileedEI
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAGE NO..'
CertainTeed Corporation Pipe and Plastics Group
3 528
SUPERSEDES:
November 2 , 1976
8
DATE OF ISSUE:
JUN 1 0 1977
DESCRIPTION:
CERTA-SPACER Bands for use with CT Pressure and Gravity Sewer Pipe
and Couplings
FIGURE I
14"$ 16
Size
14" 15" 16"
Class
All All All
O.D. Inches
12.80 13.70 14.50
Cut Length Inches
39.60 42.40 45.00
Cut Length Tol. Inches
+ .125 + .125 + .125
CTD015058
PREPARED BY:
8r:
R &D
MFG.
SALES
I.E.
OTHERS
02-10-0023
(P927)
* (MS
12/76 CONFIDENTIAL DOCUMENT NOT TO BE DISTRIBUTED TO UNAUTHORIZED
PERSONNEL
TECHNICAL SPECIFICATIONS
CertairileedEi
CerlainTeed Corporation Pipe and Plastics Group
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAGE NO.:
3 528
9
November 2, 1976
DATE OF ISSUE:
JUH 1 0 1977
DESCRIPTION:
CERTA-SPACER Bands for use with CT Pressure and Gravity Sewer Pipe and Coupling
FIGURE M
18 THRU 24
V .450
Size
18" 20" 21" 24"
Class
All All All All
Inches
16.53 18.30 19.00 21.95
Cut Length Inches
51.25 56.75 58.80 68.10
Cut Length Tol. Inches
+ .125 . +.125
+ . 125 + .125
CTD015059
PREPARED BY:
0)1
02-10-002 3 (pqg71
dftf'
APPROVED BY:
R *O
MFO.
SALES
I.E.
OTHERS
Is Ote'
12/76 confidential document - wot to be distributed to unauthopitp PERSONNEL
TECHNICAL SPECIFICATIONS
CertairileedEI
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAGE NO.:
CertainTeed Corporation Pipe and Plastics Group
3
SUPERSEDES:
November 2
528 1976
10
DATE OF ISSUE:
JUN 1 0 1977
MKKIPTIOK:
CERTA-SPACER Bands for use with CT Pressure and Gravity Sewer Pipe and Coupling
TABLE A
Physical Characteristics
Property
Original Tensile, psi Min. Average Min. Single Sample
Aged Tensile, 166 hrs. + 2 158F + 2; 7o decrease from orig.
Original Elongation at Rupture, per cent Min. Average Min. Single Sample
Aged Elongation, 166 hrs. + 2 158F + 2; % decrease from orig.
Hardness, Shore Durometer (Type A or A2)
Aged Hardness, 166 hrs. + 2 158F + 2; change from orig. points Max.
Modulus, 1007. elongation, psi Min.
Low Temperature flexibility, -25C
Ozone Resistance, 100F, 48 hrs. 50 pphm Ozone, Max. Rating
1400 1300
10
250 200
15 80+5
5 750 No Cracks
PREPARED BY:
0
CTD015060
APPROVED BY:
R ft D
MFG.
SALES
I.E.
OTHERS
t Octe
PERSONNEL
TECHNICAL SPECIFICATIONS
CertairileedEI
CertainTeed Corporation Pipe and Plastics Group
SPECIFICATIONS CLASSIFICATION:
A/C Standard Purchasing Specification
T.C-O- REP. NO.
3
SPECIFICATION NO:
528 Addendum
PAGE NO.:
1
SUPERSEDES:
OATE OF ISSUE:
JUN 1 0 1977
description:
Certa-Spacer Bands for Use with CT Pressure and Gravity Sewer Pipe and Couplings
' NOT TO BE DISTRIBUTED TO VENDORS i
Approved Vendors:
Pawling Rubber Company Pawling, New York 12564
Ktrkhill Rubber Company 300 East Cypress Street Brea, California 92621
i
I
PRCPARED BY:
APPROVED BY:
>4)
CTD015061
R ft D
MFC
SALES
I.E.
OTHERS
0<tS