Document NQ2Ko85dyE716k19oZMXx18R

OOD AND DRUG ADMINISTRATION COMPLIANCE PROGRAM GUIDANCE MANUAL PROGRAM 7306.02 CHAPTER 6 - DAIRY INDUSTRY Program Activity: Surveillance, Compliance Problem Code: FH-18 * Data Control Code: BF-320-024 Commodity Code: 17 Project Code: 05 SUBJECT: SURVEY: POLYCHLORINATED BIPHENYLS IN MILK PURPOSE To provide guidance to the districts in conducting a survey of fluid milk for the polychlorinated biphenyls. . BACKGROUND - ' In 1970 PCB1 s v/ere detected in milk samples from West Virginia. Follow up investigation revealed the apparent misuse of an electrical transformer fluid containing PCB as a vehicle for defoliant spraying operations adjacent to dairy pasturcge as being responsible for the milk contamination. PCB's have also bean found to be a component of sealcnts used to treat silos on dairy farms. Milk contamination has resulted from this source of PCB's. Subsequent information derived from the total diet studies program, the general pesticide program, and other food surveys has shown the presence of PCB's in fish, milk, eggs, in groyboard used in cereal packaging materials and in the cereal product itself. Surveys to date reveal that additional data is necessary to determine the extent of PCB occurrence in milk. Information is desired to determine the condition of milk used for bottling purposes and milk used for manufacturing purposes with respect to PCB contamination. . *' For the purpose of this survey "bottling milk" is milk which is destined for pasteurization and .subsequent bottling for direct consumer use. "Manufacturing milk" is milk intended for use as a row material in ihe production of a consumer dairy product (e.g., NFDM, condensed milk,-cheese, butter, and ice cream). OBJECTIVE '* .To survey the milk supply on a state by state basis to determine the extent of PCB contamination of milk for bottling and manufacturing use. . TRANSMIT! al no. 72-8 (2/3/72) ^ originator: Bureau of Foods, Division of Compliance Programs, ' Program Development Branch, BF-323 page i DSNN^108 STLCOPCB4082449 4 PROGRAM APPROACH . 1. Inspectional Districts ore responsible for foliov.'-up investigations including inspections if necessary to determine the source of any PCB conlamination detected. - The Districts should work with the Regional Milk and Food Consultants and state and local officials to determine sampling sources and to facilitate follow-up activities. ^ There will be no CP-1P issuance by EDRO for this program. * 2. Sample Collection * . The attached disfricf/sfafe sampling schedule has been developed from available information regarding the milk production of each state for both bottling and manufacturing use. Districts should make every effort to collect the samples as specified and to distinguish between milk for bottling and milk for manufacturing use. It is recognized that in some instances the latter will not be possible. Sampling sources should be selected on a random basis to reflect milk production and usage within each state. Samples may be collected from both interstate and - intrastate sources. District State ` Bottling Mi Ik Samples Manufacturing Mi Ik Samples Total Same ATL-DO Georgia1 Florida Alabama Mississippi Tennessee North Carolina South Carolina Kentucky 40 : 12 57-- 31 41 63 61 32 64 52 5 7 4 5 9 75 10 BLT-DO * Maryland Virginia West Virginia 13 6 6 1 3 16 17 17 12 h f TRANSMITTAL NO. 72-8 (2/3/72) * PAGE 2 DSW 338709 r* STLCOPCB4082450 PROGRAM District State BOS-DO *4 * * .Maine ' . New Hampshire Vermont Rhode Island Connecticut Massachusetts . BUF-DO New York - . .CIN-DO Ohio CHI-DO - Illinois DAL-DO DEN-DO New Mexico Oklahoma Texas *M i' North Dakota South Dakota Montana Wyoming Colorado Utah DET-DO .' KAN-DO TRANSMITTAL NO. Michigan Indiana ' Iowa Nebraska Kansas Missouri . 72-8 (2/3/72) Bottling Mi Ik Samples . 19 2 1 9 1 3 3 46 46 -17 17, .9 9 19 1 5 13 9 1 1 1 1 3 2 27 18 9 22 6 3 5 8' Manufacturing Milk Samples Total Samples 0 .- - - .- - 19 ` 2 -' 1 9 1 3 3 0 - - 2 2 46 46 19 19 4 .4 1 - 1 0 13 13 ` 20 1` 6 13 II 2 5 1 1 1. -1 5 3 2 23 13 3 2 5 20 3 6 2 2 4 3. 32 21 II 45 19 6 7 13 PAGE 3 DSW 338710 STLCOPCB4082451 PROGRAM District LOS-DO MIN-DO NOL-DO NTK-DO PHI-DO SAN-DO SEA-DO State Bottling Milk Samples Manufacturing Milk Samples Tota Samples California ' Arizona ... 20 -18 2 2 2 0 .22 . 20 ; 2 Minnesota Wisconsin .* Louisana Arkansas ' 51 10 41 7 5 2 71 122 32 42 39 80 18 5- . I3 New York New Jersey Puerto Rico Virgin Island 5* - 3 1 1 2 .- - 1 (if available) 1 (if available) 7 0 3 2 2 Pennsylvania Delaware .1 California Nevada Hawaii - Washington Idaho Oregon Alaska ' 30 29 1 20 18 1 1 15 9 2 3 1 1 I -2 2 `- 6 - 5 1 -- . 31 30 1 22 20 1 .1 21 9. 7 4 1 Totals 369 146 515 TRANSMITTAL NO. 72-8 (2/3/72) PAGE 4 DSW 338711 i STLCOPCB4082452 PROGRAM 7306.02 . ., ,., m,-,i--i iw~irr tinn--i-- n--rr~----------------------------1--rr~*"~***nri~T*******-"*^"Ti'nn n i--iT--OTnOTiwwini m tS Samples should consist of.6/qucrts of fluid milk collected from route collection trucks (bulk farm milk pick-up) on completion of pickup or from collection station points prior to further dilution of the milk at the processing plant. If milk is received in cans at the processor, samples should be collected from the holding tanks prior to process. Plastic containers or containers in which the contents come into contact with rubber or cardboard closures or inserts should not be used in the collection of samples for PCD analysis. One quart Mason jars, which have been washed to rinse out ccrdboard particles or other foreign matter which may interfere with PCB analysis, may be used. Tin foil should be inserted beneath the jar lid and screw top to prevent milk contact with the rubber gasket. . Aseptic technique (sterile ladles) should be used in collecting samples for this survey to avoid adding to the bacterial load of the bulk milk from which the sample is collected. Samples may be official or investigational. ^Collection reports should be flagged "PCB Milk Survey" and should include the following information. '- ' ' I. State where collected. ' 2. Point of collection (e.g., route truck, holding tank, etc.). 3. Volume of milk sampled. 4. Number of producers represented. 5. Type of milk (e.g., bottling, manufacturing). . . . . 6. Milk route number or patron(s) can number. 7, Route truck number or license number. * See Inspector Operations Manual, Chapter 4, Sections 443.2, 452.2, 454, and 454.3 for guidance in sample handling, shipment, and notification of receiving laboratory. 3. Sample Analysis Analyze samples for PCB, organochlorine and organophosphorus pesticide residues using appropriate PAAA Vo I. I methodology for extraction, cleanup, and GLC determination: extraction 2ll.!3h(!) (4/1/7! revision) cleanup, 211.14a,d (4/1/71 revision); EC-KCL7D GLC, 321. Inj ect approximately 3 mg milk fat equivalent for GLC. Analyze 20% of the District sample quota (with a minimum of four samples) for the chlorophenoxy acid residues. . Determine residues of pesticides In the usual manner. Evaluate EC-GLC chromatogram of 6% Florisil eluate for presence of PCB and pesticides. If presence of PCB is indiccted, complete analysis using the necessary treatment of extract prior to GLC determination. transmittal no. 72-8 (2/3/72) 5 page STLCOPCB4082453 In most instances when both PCB and DDT and analogs are present, the PCB and organochlorine pesticides require separation by chromatography on silicic acid [Armour and . Burke, JAOAC 53, 761 (1970)] prior to determination. In some instances dehydrochlo rination of DDT and TDE to their respective olefins [Sawyer and Krause, LIB 1249 (Jon. 8, 1971)], ora combination of dehydrochlorination followed by oxidation of olefins to the respective dichlorobenzoohenone [Mu I hern, et al, JAOAC 54 , 548 (1971)1 will permit quantitation of PCB without-column chromatographic separation. Appropriate treatment will depend on the PCB [Aroclor(s)] indicated present, the particular pesficide(s), and the relative amounts of PCB and pesticides. Aroclors 1221, 1232, end 1242 divide between the petroleum ether and polar solvent eluates from the silicic acid column, but residues of these Aroclors can possibly be quantitated in the presence of DDT end analogs, and would not necessarily require column chroma tographic separation from these pesticides. . Previous experience indicates that PCB residues in cows' milk will be more similar in GLC pattern to Aroclors 1254 or 1260. . Quantitate PCB residues by electron capture GLC or by use of halogen specific micro- coulometric or electrolytic conductivity GLC detectors. Compare the total area response from the PCS residue to the tote! area response from a known weight o f the Aroclor with most similar GLC pattern. However, if the GLC curve shows that the PCB residue clearly consists of components of more than one Aroclor, if possible ` quantitate the residues separately using the appropriate Aroclor reference for the respective portion of the GLC curve. When PCB residue is 5 ppm or above in the fat, confirm residue identity by GLC v/ith halogen specific microcoulometric or electrolytic conductivity detectors end/or demonstration of the residue's stability to boiling alkali. Additional confirmatory analyses are left to discretion of the Laboratory Director. Limit of detection for PCB residue in milk fat is approximately 1.5 ppm (as Aroclor 1254), when using a 3 mg sample injection and EC-GLC operated at the above conditions. Report PCB residue in terms of Aroclor(s) used in quantitation (e.g., 2 ppm Aroclor 1242 and 3 ppm Aroclor 1260). PCB residue levels in milk fat should be rounded off to the nearest 0.1 ppm. transmittal no. 72-8 (2/3/72) page 6 DSW 338713 STLCOPCB4082454