Document NNp8QpqRZ5v721w0Ko1ZQB8LQ
ABDOO136637
PMc
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month of: February Date of Report: April 3, 1984
1. ROUTINE CHEMICAL DOSIMETRY
All Sample Results:
Chemical
VCM Lead Total Particulates
Overexposures
< PEL No. %
25 96.2 32 97.0 12 100.0
> PEL (OVEREXPOSURE') No. %
1 3.8 1 3.0 0 0.0
Job Class
Exposure
Source
Line Compounder
61.1* Micrograms Lead/m-5
Employee overexposed while charging Line III blenders. No specific cause has been identified.
Chief Operator
29.1* ppm, VCM
*Respiratory protection worn. 2. NOISE CONTROL
Employee overexposed while helping change VCM filter pack filters.
Resin deboxing area noise was reduced during February by insulating the cone at the bottom of the Sweco screener feed hopper. Noise level measurements taken before and after the insulation, using a General Radio Model 1565-B sound level meter, were :
Location
Noise Level, dBA
Before Insulation
After Insulation
1. 2 ft. from cone, on mezzanine
110
98-103
2. 16 ft. from cone, at ground level
95
92
3. Main traffic isle, at south door*
93
89
*84 dBA with hopper vibrator "off".
Industrial Hygiene Report Page 2
ABDOO136638
3. GMD SYSTEMS, INC, PASSIVE MONITOR
The lab-based familiarization study of the passive, VCM monitor marketed by GMD Systems, Inc. was completed. The second phase of the evaluation, involving reproducibility studies, was begun.
cc: JF, CRM, PEM, PJK, LPS, WFH, CRS, RAF, RAM, AHS Tom Grumbles - Houston J. R. Drumwright, M.D. - Ponca City
(
%< PEL
100
VCM
0
ABDOO136639
ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
(