Document NNmq197pp6ebvZpwmqrqnq1dD
Kcloinator
Air Conditioning, Automatic Heating Systems
Gas-Fired Conditioner. Available in 3 lines, 4 models
in each. Capacities from 90,000 Btu/hour to 200,000 Btu/
hour. The Kelvinator gas-fired conditioner is a completely
automatic heating system making use of gas. This con
ditioner maintains uniformly comfortable temperatures and
also accomplishes a complete winter air conditioning effect
by cleaning, humidifying and circulating the conditioned air
throughout the house.
The gas-burning unit is of the atmospheric, individual
port, up-shot type with automatic gas valve pressure regu
lator. Safety pilot prevents opening of main control valve
in the event that flame should be extinguished. This insures
absolutely safe operation.
Kelvinator Oil Burners.
Kelvinator conversion oil bur
ners are especially developed to
insure quiet, dependable, and efficient performance in con
Kelvinator Gas-Fired Conditioner.
ventional heating plants.
They employ the pressure-atomizing principle. By
means of a scientifically designed turbulator and air de
flector, thorough mixture of the air with the atomized oil is
achieved. This results in complete burning of the fuel
within the combustion chamber, and makes the full amount
of heat available from low-cost, heavy grades of domestic
fuel oil.
Kelvinator Con
Seven models of burners may be fired at oil rates from
version Oil Burner. 1.25 to 25 gal an hour with capacities up to 2,270,000
Btu/hour.
Kelvinator Coal Stokers. Kelvinator
Automatic Coal Stokers introduce important
improvements in the automatic firing of bitumi
nous fuels. They utilize the proved underfeed
principle. Gases, ordinarily wasted, are scien
tifically released and thoroughly burned over a
slow-burning coke fire. Combustion is com
plete and smokeless.
Burner is made of nickel-steel tuyere seg
ments, with special air vents which distribute
air uniformly to the fuel bed. A controlled air-
damper regulates air flow automatically, and
holds the fire down when heat is not required. .
Kelvinator
Coal feed is by a cast steel tapered worm, full
Automatic Coal Stoker.
floating in a seamless steel tube. Transmission
gears are drop-forged steel, case-hardened and ground, operating in a continuous bath of
oil. An easily accessible adjustment provides the choice of 5 different speeds. Feed is
intermittent, providing the very necessary poking action in the fire bed. A special coal
agitator is available for use with fuels
\that have a tendency to cake.
Construction provides easy accessi
bility of all working parts for adjust
ment or service. Coal hopper of smaller,
household size models, holds more than
a day's supply of coal. Hopper cover is
gas tight, preventing any possibility of
blow back of smoke or dust.
Five sizes of Kelvinator stokers are
available with maximum feeds of 35 to
150 lb per hour and capacities of 210,000
to 900,000 Btu/hour.
Kdvinator water-cooled condensing unit for summer cooling.
Kelvinator Condensing Unit
See paragraph on Kelvinator Condensing Units under Commercial Air Conditioning Section.
916
Air Conditioning, Automatic Heating Systems
he Me/er Furnace GhMPANy
Peoria. Illinois
Manufacturers of Domestic Heating and Air Conditioning Units for Coal,
Gas and Oil Burning
Branches and Distributors
Kansas City, Mo. Omaha. Nbb. Green Bay. Wis. Pittsburgh, Pa. Philadelphia. Pa. Detroit. Mich. St. Louis. Mo. San Francisco. Calif. Columbus. O. Minneapolis. Minn.
The WEIR Air Conditioner for solid fuels (hand or stoker fired) embodying the famous WEIR Steel Furnace is a complete unit for winter air conditioning, including air
cleansing, humidifying and forced circulation
as well as heating. Encased in furniture steel with baked enamel finish. Automatic con trols for dampers, blower, humidifier.
WEIR Conditioned Air Unit
WEIR Gravity Heater
Ratio Smoke
No.
Grate Surface
Htg. to Grate
Outlet Diam.
(Sq Ft) Surface (In.)
Gravity Circulation
Caving Dimen.
Rated Output
Round Rect'lar At Reg. Pipe Area
(In.)
(In.) (Btu. Hour) (Sq In.)
Fan Circulation
Casing Dimen.
(In.)
Air RatedOutput Delivery . at register (CFM) (Btu.Hour)
621 1.26 624
628 630
633 636
540 544 7.60
18.5
WEIR Oil Fired A ir Conditioner
54.400
400
10 52 47x50 73,600
541 47x90
1200
92,000
10 54 50x52
94,100
692 50x99
1600 118,000
10 58 54x56 119,000
875 54x103 2000
148.000
10 65 56x64 138,000 1015 56x110 2300 172,000
10 67 56x66 160,000 1160 56x118 2700 200,800
12 12
60x106 64x114
4000 5000
264,000 316,000
The WEIR Oil-Fired Air Conditioner does a complete
job of winter air conditioning. Designed for oil fuel and forced circulation. Completely self-contained in low compact casing enclosing burner and blower as well as heater and all
controls, yet with everything easily accessible. The MEYER Gas-Fired Air Conditioner automatically
provides completely controlled winter air conditioning. Effi cient in performance, compact in design, and modern in appearance. Heavy gauge welded steel heating section; die-
formed furniture steel casing. A.C.A. approved.
No.
Input at
Burner
(Btu/Hour)
Output
at Bonnet
(Btu/Hour)
Vent Diam.
(In.)
Dimensions W. L. R (In.) (In.) (In.)
Air Delivery
Vs In.S.P. (CFM)
Motor Size (HP)
MEYER Gas Fired Air Conditioner
125-A 175-A 225-A
E-I0 E-15 E-20 E-30 E-45
165.000 260,000 335,000
110.000 165.000 220.000 330.000 495.000
WEIR Oil-Fired Air Conditioner
125.000. 8 48 68 48
175,000
8 56 68 48
225,000
8 63 68 48
MEYER Gas-Fired Air Conditioner
88.000 132.000 176.000 264.000 396.000
5 32 69 45 6 41 69 45 7 53 69 45 9 69 69 45 10 97 69 45
1700 2300 3000
1200 1800 2400 3600 5400
i/j /3 1/2
'1/3i
1/3 1/2 3/4
C-100 C-120 C-150
100,000 120.000 150,000
MEYER Gravity Gas'Furnace
75,000 90.000
112,500
5 38 38 60 6 42 42 67 6 42 42 67
Complete descriptive literature, including data on Summer cooling, upon request
MEYER Gravity Gas Furnace
The MEYER Gas Furnace--Efficient -Economical--All Steel, welded heating section, die-formed insulated casing. A.C.A. approval.
917