Document NNmN4r7VYpxbB4knvVKeVgDQ

B-l EXHIBIT B PCB CONTENT MEASUREMENTS ------------------5H------------------ DUPLICATE-samples I UMC Capaoltor Plant Bridgeport, Ct. Duplicate samples of approximately one gallon each were taken by EPA Region I personnel. In January 1976, and one set left With us. After mixing thoroughly, I decanted one set Into pre-rinsed one-liter bottles, and sent them to Baron Consulting Co., a laboratory In Milford, Ct. The remainder, still In the bottles supplied by EPA, were sent to WOodson-Tenent, a laboratory in Memphis, Tennessee. The comparative results are tabulated as follows! (Note! The dual numbers for Baron'Consulting for Sample 1 represent a duplicate run.) Sample Identification RESULTS PPB Baron Woodson . Regional Consulting ' Tenent EeP.As 1 Incoming water 1/28/76 0.65/0.58 0.075 0.5 2 Effluent cooling water 1/28/76 1.95 10.51 13. 3 Effluent eoollng water 1/29/76 4 Effluent Sanitary.water 1/28/76 1.71 1.24 0.97 . 62.68 17. 20.. 5 Effiuent Sanitary water 1/29/76 6 Effluent Air Compressor Cooling water 1/29/76 8.5 no sample 348.57 no sample 89. 8.3 XX UMC Capaoltor Plant, Totowa, N.J. Duplicate samples were taken by EPA Region XI personnel In February 1976, and one set left with us. The retained sample was sent to Baron Consulting Co. The comparative results are as follows! Baron Consulting EPA Region II Influent compositet Effluent composite: Orab sample from waste collection tank: None detected 67. ppb 12.6 ppm 0.95 PPb 9.90 ppb 16.2 ppm This sample contained an extraneous unidentified peak, not PCB. HONS 0 2 9 8 0 6 EXHIBIT \ page 2 III City of Bridgeport) Ct. Waste Water Treatment Plant. Samples were taken In May 1976 by EPA Region I personnel. We did not receive a sample, but the following results were reported to me by Mr. Daniel Moon of EPA Region I: Water Influent to treatment plant Water effluent from treatment plant 1.42 ppb 11.3 ppb XV These are grab samples wh'leh I took on September 7, and were taken by holding the pre-rlnsed bottles In the stream flow and allowing them to fill simultaneouslyt Sample ' Identification RESULTS PPB ___________ Saron Consulting Galbraith Labs Inc. 1, Bpt. Influent Tap Water 9/7/76 Hone detected PP*> 15 Aroolor 1016 3 Aroolor 1254 2. Bpt. Effluent (rat'd to well) 9/7/76 Non? detected PPb ` 16 Aroolor 1016 4 Aroolor 1254 NRC/h l HONS 029807