clutch control relays, and control transformer This panel should be on or immediately ad jacent to the machine it serves, but out of the operator's way during normal operation It should be properly identified and accessible for maintenance (Fig 25-38)
The main disconnect switch handle should be on the extenor of the control enclosure and operable from floor level The recommended maximum height of the centerline for the switch handle is 6% ft above the floor The switch should be provided with a means for positive lockout
Selector switches used for setting the mode of operation --such as single-stroke, run, inch, two-hand, or foot--should be of the key-lock type to prevent unauthonzed change of op eration
Operating controls should be located or guarded to minimize the possibility of unin tentional operation Foot switches should be guarded to prevent activation by falling ob jects or by accidentally stepping on them A foot switch should only be used where satis factory operator protection is provided Hand buttons should be physically located or guarded so that operation by a single hand and arm or elbow is impossible Stop buttons should be conveniently and conspicuously located and left unguarded Emergency stop buttons should be mushroom shaped and colored red
All operating buttons should have metal cases and covers Where mushroom heads of run buttons are used, they should be of metal or plastic (metal preferred) and grounded to protect the operator from shock m case of electrical defect
Cases or frames of all control devices should be grounded to the press frame Mounting bolts are satisfactory for grounding provided all paint and dirt are removed from joint sur faces before assembly Movable control de vices not secured to the press frame should be grounded by means of a grounding conductor in the connecting cable or conduit
The rotary limit switch is a vital element in the control system Mechanical or electrical
failure of this switch may cause the press to repeat The switch driving mechanism--in cluding all couplings, gears, sprockets, and associated parts--should be securely assem bled and of rugged design A positive, keyed connection is preferred to set screws, as these
have a tendency to vibrate loose The use of two separately driven switches
or a drive failure detector is recommended All cam switches should be of a type in which the switch contacts are forced open by the actuating cam 1 Where a flywheel brake is used, it should
be electrically interlocked with the mam drive starter to prevent simultaneous op eration 2 When safety blocks are used, they should be provided with interlock plugs which disconnect the clutch and motor control circuits when blocks are m place between the dies (See Fig 25-39 )
Fig 25-39 --When making adjustments on press, the upper die should be propped to eliminate any unexpected motion Courtesy McDonnell Aircraft Corp
727