Document NN20BkVZzKJYnz1VZqNeoOdOQ

TABLE XIV ASBESTOS CONCENTRATION BY OPERATION*, 1969 Average asbestos fiber level Work practice 01 Asbestos cement 02 Asbestos cement 03 Asbestos cement 04 Asbestos cement Cutting calcium sili cate, block, pipe 01 Environmental conditions Personal Area Samples Samples Distanc Fibers/ml Fibers/ml from Sour High ceiling room. Louvre venting 2.4 .45 Low ceiling room. Poor ventilation 2.6 -- Access tunnel 6.1 -- Power house. Low Ceiling, poor ventilation Table and hand saws, in power house - open 3.9 1.2 2.5 3-5' Cutting calcium sili cate, block & pipe 02 Same - in industrial building. Good ventilation. 4.1 . - Cutting calcium sili cate block & pipe Apartment house boiler room. 11.5 No ventilation. Work 3"-18" from breathing zone. Cutting calcium sillcate block & pipe 04 Limited ventilation 9.4 1.6 3-4' Spraying insulation Turbines in power plant very high ceiliivg, good ventilation. 47.7 19.5 3' 28.0 6' Fibers/ml >5^j in length Notes: 1. Conditionj usually variable: Cement mixed dry - applied wet; rapid changes in local ventilation; composition of naterial may vary; number of men on job may vary. 2. Average of counts (excluding spray insulation) : >5 fibers/ml ** 64.5%; 5-12 fibers/ml - 25.5%; 712 fibers/ml - 10.0%. /5n 3. Information prepared by Reit2e, Nicholson, and Holaday. A0407o