Document NKQeojwqb9jb9NMpxg20p1EE
466
CHAPTER 19
1956 Guide
Table 1. FirstStoey Warm Ajb Ducts*
Warm Ajb Combination
No.
Throat Sue
Leader Pipe
Diameter,
Inches
Pipe Area
Sq In
Register-'Size, Inches
Baseboard Size Extension
Floor
i 6% X 10 2 6% x 12
3 7% x 12
4 9% x 13
3db m x 12 4db 10% x 12
8 9 10 12
10 12
50
10 x 8
Wa.
8x10
64
12 x 8
u
9 x 12
78
12 x 9
334
10 x 12
113
13 x 11
5%
12 x 14
78
2(12 x 8)
2M
113
2(12 x 9)
m
* When the calculations indicate a requirement for a given room greater than Combination No. 4, two or more smaller units totalling the required capacity are recommended.
b Double headers are permissible only where full throat areas are obtainable and room privacy is not essential. Use combination number representing total load. Combinations 3d and 4d have same capacities in Table 6 as combination 3 and 4 respectively.
Table 2. Second Story Warm Air Ducts--Single Wall Stacks and Fittings
Combi* nation
No.
Stack, Size,
Inches
. Leader Pipe Di ameter,
Inches
Pipe Area
Sq In
InchesRegister Size, Baseboard
Floor Size Extension
Sidewall
u
12
14 15
16 12db
14db
10 x 3% 12 x 3% 14 x 3%
12x534 14 x 534 12 x 3% 14 x 3%
8 9 10 12 12 9 10
50 10 x 8 64 12 x 8
78 13 x 11 113 12 x 9 113 13 x 11
64 2(12 x 8) 78 2(12 x 8)
234 8 x 10 234 9 x 12 234
10 X 8 12 x 8 12 x 8
334
534 234 2(12 x 8) 234 2(12 x 8)
* Recommended stack sixes. Tables may *!<> be applied to 3 in. and 3 1/2 in. stack depths. b Combinations 12-d and 14-d have same capacities in Table 7 as combinations 12 and 14 respectively.
Table 3. Second Story Warm Air Ducts--Double Wall Stacks and Fittings
Combi
nation
No.
Leader
Pipe Di
ameter,
In.
Pipe
Area
Sq In.
. Stack Size, In.
Internal
External
21 8 50 2J4* x 10 334* x 10% 22 8 50 3 x 10 3% x 10% 23 9 64 234* x 12 334* x 12% 24 9 64 3 x 12 3% x 12%
* Commercial sizes vary 1/8 in. from values shown.
Register Size, In.
Floor
8 x 10 8 x 10 9 x 12 9 x 12
Baseboard
Size
10 x 8 10 x 8 12 x 8 12 x 8
Ex tension
234 234 234 234
Sidewall
10 x 8 10x8 12x8 12 x 8
all correlated. Similarly in the case of return ducts, the selection specifies a complete unit consisting of return grille, return duct, and shoe connection.
Recommended Standard Sizes
For the purpose of simplification and standardization, selected combina tions of commercial sizes of warm air pipes, return air pipes, ducts, grilles, fittings, and registers are designated as Combination Numbers. The numbers assigned and the combinations selected as standard are fisted in the following Tables 1 to 4 inclusive.3
The selected types of fittings are shown in Fig. 2, and their resistances 6x-
Gravity Warm Air Systems
467
Table 4. Return Air Ducts
Combi
nation
No.
Duct Dia. In.
Duct Area Sq. In.
When Joist -Space.
Is Used*
No. of Min.b Joists Depth Lined In.
Metal Grille Srrra
Choose One ABC
Base-;
board Intake pob First
Stobt
When
Area at Shoe Con
Duct
Is Used
nection, Sq. In;
Choose One
31 10 78
7
8 x 14 10 x 12
32
12
113 or 2
9 5
6x 30 8x 24 12 x 14 14 x 10 4-In. Ext.
33
14
154 1 12 or 2 6
8x30 10x24 14 x 16
. 170
34
16
201- . . 1 or 2
15 ` 10x30 12x24 8;
220
35 18 254 36 20 314
2 10 12x30 14 x 24 2 12.5 14x30 18 x 24
30 x 10 4-In. Ext.
' 280 340
37 22 380
2 15.0 18x30
420
38 24 -452.^ 2 18.0 20x30
'
500
14 x 6 12 x 8
22 x 6 16 x 8
28 x 6 22 x 8
28 x 8 22 x 10
36 x 8 28 x 10
36 x 10 30 x 12
42 x 10 36 x 12
42 x 12 36 x 14
* Based on 14 in. space between joists.
b Use full depth of joist except when joist depth is less than minimum depth required, when pan mxut be
need.
. . .
bc
^{0 F/oor Register
G
Fig. 2. Typical Warm Air Boots