Document NGqgRj91w9bpQaXB6qOZpkLzy
Inspection Report
Mechanical Integrity Test
Osage DNR / Environmental Protection Agency
1201 Elm Street, Suite 500
Dallas TX 75270
Inspector Matthew Allen
MIT Date 02/17/2026
Operator Representative McCann Resources, Inc
Report Sent Operator
Time 15:00
Inject Interval 666 - 673
USDW 251
Well Type Enhanced
Recovery
Annulus Fluid Type Casing 4.5
Concentric Pkr Tubing
Packer Depth
Operator Info
McCann Resources, Inc 1613 West 6th Street Bartlesville, OK 740033404 Phone: 918-337-4747
Inventory ID API Well No Lease Name
Well ID
OS2217000
Parker W-85
Location SW 15 27N 12E
Type of MIT Ada Pressure Test
Test Reason Compliance Request
Injecting N
Injection Rate (bpd)
Tubular Lining
Ann Filled (hrs)
MIT Due
MIT Freq EVERY FIVE YEARS
Ann Press Mont
Time Pre-Test
Tubing Pressure 0
Annulus Pressure
Flowback Pressure High
Volume
Initial 15:00
300
Mid
Mid 15:15
300
Low
Final 15:30
300
End
Total Volume
ADA Pressure Test - Required Test Pressure
(Fluid Column Ht * Specific Gravity * .433 / N2 Wt Fac =
Required Test Pressure)
Tubing
Annulus
Depth to Top Perf/Open Hole 666 Depth to Fluid Level 0
Fluid Column Level 666
Specific Gravity of Fluid 1.06
Nitrogen Weight Factor 1.0239
Required Pressure Test 298.540
Remedial Action Type
Fluid Migration Test Type
Inspection Comments
Inspector Signature
Remedial Action Type Well, OS2217000 consisted of casing reduced to a ball valve, there was no tubing or packer in the well. The well was disconnected and not injecting. The well achieved a test pressure of 300psi and maintained the pressure for the required 30-minute observance period.
MATTHEW ALLEN Date: 2026.03.02 11:39:28 -06'00' Digitally signed by MATTHEW ALLEN
Supervisor Signature JEANNE ECKHART Date: 2026.03.03 05:55:18 -06'00' Digitally signed by JEANNE ECKHART