Document NGq8QXn0Q7ZMQ9xve9w64NK08
Air Conditioning Furnace Systems
The Henry Furnace & Foundry Company
Manufacturers of MONCRIEF Gravity and Air Conditioning Pipe and Fittings--Gravity Furnaces and Air Conditioning Units
3471 East 49th Street
Cleveland, Ohio
Phone Michigan 9322
Moncrief Aristocrat and "Special" Oil Fired Winter Air Conditioners, made to operate with any standard Gun Type Burner, and Gas Fired Winter Air Con ditioners are available in numerous sizes and capacities. Coal Fired Cast and Steel Air Conditioning Units are made in various sizes. Data in complete catalog form. Write for particulars.
Aristocrat Oil Fired Air Conditioner "SPECIAL** OIL FIRED AIR CONDITIONERS
Unit No.
Size of casing: Width........................................... Height ......................... .............
Cfm.............................................. No. filters 13 z 25........................
75
.76
28* 7r 605/8* n6 1/6 6120 915 2 75.000
100
1.02
28* 71* 603/e* 112 /* 6120 1225 2 100.000
SIZES, CAPACITIES--Aristocrat Oil-Fired Units.
Aristocrat Gas Fired Air Conditioner Approved by American Gas Association
Btu Per hour at Reg. Cfm Blower Size Blower Motor Hp || Sq In. Heating ' Surface Size of Filters
wSS*
(Approx.)
.*5
=?i ^.S A
Casing Dimensions, In.
Plenums
Warm Cold Air Air
~c~ b E F G | H T K L M N
O
6 Z
If
125 150 175 200
275
765/8 765/a KVA eoA
101
5|3/a 51 Ve
51^
605/e 60V.
m 64
48%
52V) 52% 59
28 78 26 28 42
51 Vi 383/8*556 51# 38# 5% 5I& 43%*% 514 43,/,3y. 5iy. 47 5$
16 18 Ifl 18
18
20 24 24 24 30
28 28 32 36 40
20 28 125,000 1525 112 24 28 150,000 1830 114 24 32 175,000 2200 114 24 36 200,000 2440 114 30 40 275,000 3350 214
V, /.
%H
%
8925 8925 11088
11088 13248
4 4
5 6
7
16x25 1240 1.28
16x25 1265 1.53 16x25 1365 1.8 16x25 1455 2.04 16x25 2010 2.8
SIZES,-CAPACITIES--Aristocrat Gas-Fired Units.
AGA Btu Input Per Hour Btu Output Per Hour | Blower Size Motor Hp* No. of Filters |j Filter Size 140 Reg. Temp. Cfm. Sq In. Heating Surface Gas Line j| No. of Burners
Unit .Number.
Casing Dimensions, In.
Plenum Size. In.
Warm Air
Cold Air
A BC DE K L M N
'AG- 8 73% 20 56% 7% 9% 12 30 12 18
C-12 G-16
730? 73$
26 34
56$ 56%
9% 18 30 18 -18 9% 24 30 24 18
G-24 73 49 56'/. T>h 9Vi 34 32 34 19
80,000
120.000 160.000
240,000
64.000 96.000
128.000 192,000
no Vi 112 /, 112 y. 114 Vi
2 16x25 857
3 16x25 1285 4 16x25 1714 5 16x25 2570
5410 1* 8115 1* 10820 1* 16230 we
a to
3 u.
2 6* 3 7* 4 8* 6 2-7*
*Be sure to specify characteristics of gas and electric current available.
822
Air
Conditioning
Fart Furnace
Systems
JTSe Me/er Furnace GhMPANy
Peoria, Illinois
Manufacturers of Heating and Air Conditioning Equipment for Coal,
Gas and Oil Burning
Branches and Distributors
Kansas City, Mo. Omaha. Neb. Green Bay, Wis. Pittsburgh. Pa. Philadelphia. Pa. St. Louis, Mo. Columbus. O. Minneapolis, Minn. New York. N. y. Atlanta, Ga.
The WEIR Air Conditioner for solid fuels (hand or stoker fired) embodying the famous WEIR Steel Furnace is a complete unit for winter air conditioning, including air cleansing, humidifying and forced circulation as well as heating. Encased in furniture steel with baked enamel finish. Automatic con trols for dampers, blower, humidifier.
WEIR Conditioned Air Unit
WEIR Gravity Heater
No.
Grate Surface (Sq Ft)
Ratio Htg. to
Grate
Surface
Smoke Outlet
Dtam.
(In.)
Gravity Circulation
Casing Dimen.
Rated Output
Round Rectlar At Reg. Pipe Area
(In.)
(In.) (Btu.Hour) (, In.)
Fan Circulation
Casing
Air Rated Output
Dimen. Delivery at register
(In.) . (CFM) (Btu. Hour)
621 1.26 624 1.78 628 2.32 630 3.08 633 3.82 636 4.74 540 6.25 544 7.60
41.2 33.9
29.2` 26.4
22.7 19.4
19.3 18.5
9
10 10 10 10 10
12 12
48 54,400
52 47x50
73,600
54 50x52
94,100
58 54x56 119,080
65 56x64 138,000
67 56x66 160,000
400
541 47x90
1200
692 50x99
1600
875 54x103 2000
1015 56x110 2300
1180 56x118 2700
58x108
6100
200^800
JW.UUI 360,000
WEIR Oil Fired Air Conditioner
The WEIR Oil-Fired Air Conditioner does a complete job of winter air conditioning. Designed for oil fuel and forced circulation. Completely self-contained in low compact casing enclosing burner and blower as well' as heater and all controls, yet with everything easily accessible.
The MEYER Gas-Fired Air Conditioner automatically provides completely controlled winter air conditioning. Efficient perform ance, compact design, modern appearance. Heavy gauge welded steel heating section; die-formed furniture steel casing. A.G.A. approved.
Input
Output
Burner
Bonnet
(Btu/Hour) (Btu/Hour)
Vent Lham.
(In.)
Dimensions
W. L. H. (In.) (In.) (In.)
Air Delivery
% In. S.P. (CFM)
Size (HP)
MEYER Gas Fired Air Conditioner
A-100-M A-125-M
A-150-M A-175-M
A-225-M
140,000 165.000 212.000 260.000
335.000
WEIR Oil-Fired Air Conditioner
110.000 140.000 165.000 195.000
* 250.000
6 25 71 48 8 48 68 48 8 32 78 48 8 56 68 48 8 63 68 48
MEYER Gas-Fired Air Conditioner
1300 1700
1950
2300 3000
F-10 F-15 F-20 F-30
F-45
(10,000 165,000 220.000
330,000 495.000
88,000
132,000 176.000 2S4.000 396,000
5 '6
7 9
10
32 69 48 41 69 48 53 69 48 69 69 48 97 69 48
1200 1800 2400 3600
5400
|/4 1/4 1/3
3/4
MEYER Gravity Gas F urnace
MEYER Gravity Gas Furnace
J- 90 J-135
J-180
J-225
. 90.000 135.000 180.000 225,000
67,500 101,250 135,000 168.750
-4
5 2-4*
1-4*. 1-5*
32Vi wA wA
74Vi
30
- 30 30 30
47'/; 47Vi
Complete descriptive literature, including data oo Summer cooling, upon request
The MEYER Gas Furnace--Efficient--Economical--A.G.A. approval.
823