Document NGk4pNbX9wZd6pJM7ZnQ42KYR
Heating Systems
MSorXcts
National Clay Pipe Manufacturers, Inc.
Washington 6, D.Q.
VITRIFIED CLAY PIPE FOR UNDERFLOOR HEATING DUCTS Conforming to ASTM Specifications C-13
Size, in.
)
Laying Length (L>
Nominal, ft
Limit
of Minus Varia tion,*
in. per ft of
length
Maxi mum Differ ence
in
Length
of Two Op
posite
Sides, in.
Outside Diameter of Barrel, in.
Min. Max.
Inside Diameter of Socket at H in.
Above Base, in.
CDs)
Depth of Socket, in.
(Ls)
Thickness of Barrel, in.
(T)
Min.
Max.
Nom inal
Min.
Nom inal
Min.
Thickness of Socket at H in. from Outer End, in.
(Ts)
Nom inal
Min.
4 2, 2H, 3 X 6 2, 2M, 3 X 8 2, 2X, 3 X 10 2, 2M. 3 X
He 4H 5X 5K 6H IX m X He He X
mH 7He 7He 8He
2X 2
% He X He
mHe 9X
10H ii 2H 2H X `He He X
He 11M 12 12X 13H 2% 2H X `He X He
There is no limit for plus variation.
338
Heating Systems
Baseboard and Under Floor Ducts
National Clay Pipe Manufacturers, Inc.
Washington 6, D. C.
Storage There are no storage problems, because vitrified clay pipe heating ducts can be exposed to weather in any season.
Performance in Use Clay pipe ducts have such advantages as permanence, resistance to shock loads, and resistance to corrosion from lime in the concrete. They create no odor as warm air flows through them during furnace operation. The smooth inner surface eliminates turbulence and mini mizes register noise. The clean smooth surface of the Vitrified Clay Duct is free from dust.
Design Data Detailed design recommendations have been prepared by the National Warm Air Heating and Air Conditioning Association and are contained in the new revised edition of Manual 4 (tl-50) and Manual 9 (f.7), which are available from the association's offices, 145 Public Square, Cleveland 14, Ohio. Manual No. 4 de scribes warm air perimeter heating Bystems as applied to structures without basements. Manual No. 9 contains de tailed information on design and instal lation of warm air winter air conditioning systems and all necessary engineering data, tables, and recommendations for se lection of the proper heating equipment.
Case Histories For data on actual case histories of Clay Pipe heating, ventilating, and air condi tioning duct installations in homes, schools, churches, hospitals, factories, gasoline stations, garages, stores, and theaters, write the National Clay Pipe Manufacturers, Ihc., 1820 "N" St., N.W., Washington 6, D. C.
Large diameter clay pipe heating duct and plenum con nection used in commercial structure. This type of duct,
when installed in garages and maintenance or repair shops, can be used for healing, ventilating, atr condi tioning, and removal of exhaust gases. When the registers
are located under the windows, the warm air will blanket the glass area and eliminate frosted and wet windows,
sills, and walls.
Clay Pipe Heating Ducteready for the concrete pouring. Wire mesh may be installed at the contractor'e discretion <o reinforce the floor slab.
339