Document NGjEygqXxw1wjKORD8n5GVDGE
Monsanto
IMAM >NAM( * I0t*1""" L. B. Press - St, Louis General Offices
IMU
Nl I (Ml MCI
TO
December 6, 1968 KIMBERLY CLARK HASTICIZER CALL REPORT FILE
cc D. H. Bechtold - Chicago G. L. Judy - Chicago F. Sturm - Atlanta N. W. Touchette - Res. JFQ W. F. Waychoff
-------- yl. R. ftirby - Res. JFq w. K. Johnson - WJOHN
DATE OF CALL:
December 4, 1968
FOR KIMBERLY-CLARK:
Mr. LeRoy Goldbeck Mr. Gene Condon
SUMMARY:
Since the trial at Balfour of the 75/25 DOP/Aroclor 1254 blend resulted In symptoms of vapor toxicity of the plant personnel, the use of Aroclor 1254 Is temporarily abandoned. Because the Aroclor won't be used, interest Is agin high about the use of Santlcizer 148 and possibly Santlcizer 160, to be used In com bination with DOP. The general subject of flame retardancy was discussed and specifically the use of Santlcizer 148, Santlcizer 160, chlorinated paraffins and metal salt flame retardants. Plastlsol properties of SaDtidzer 148 vere again reviewed, as well as patch testing results.
1. Aroclor_Plant Trial - The plant trial at Balfour of the 3/1 DOP/ Aroclor f54 bTe~n3~proceeded Bmoothly, producing desirable product. Every aspect of the production was satisfactory, except the ability of the ventlllatlon system to remove the Aroclor vapors. Plant personnel experienced respiratory and eye Irritation during the limited trial,
The ventlllatlon system of the existing equipment likely cannot be up-graded adequately to handle the Aroclor fumes. Therefore, this use Is temporarily Bhelved. In approximately ljt- years a new production line will be constructed, which presumably will be designed to handle Aroolors.
2. Santlcizer 140 Bkln Irritation patch testing was reviewed. A Complete `copy of the Santlcizer 148 multiple Insult test!ng was promised for Fr. Bletzsinger. He has the report from the previous Uchwartz test!eg we performed.
MUNS 0UG3B2
-2
3. Santlelzer l60 skin Irritation patch testing was reviewed. EeRoy indicated that the reactions were so slight that he would not he concerned about trying to use it as a part of the plasticiser system. Of course, such a system would have to be patch tested.
4, Optimized plasticizer blends using Santlelzer 148 for flame retardance were discussed. 1 suggested that they start with about a 1:1 santlelzer l48/l>OP blend In their 60-70 PHR plastlsol and then vary the ratio in about 4-3 PHR Increments to deter mine ratio for optimum flame retardance. The use of Santlelzer 160 In place of DOP would warrant starting vith about 10$ less Santlelzer 148 In the blend.
3. A flame retardant additive, some metal salt, is used as a part of the plastlsol. Identity of this additive was not disclosed. The consent was made that the salt Is oomewbat water soluble, but not of serious consequence because of the disposable nature of the product.
6. Composition of combustion vapors is of extreme concern to the US government,'since one of their customers is a VA hospital. So far Kimberly-Clark has given evasive answers, but expect that soon they will have to give a definite reply. That phosgene may be present In the smoke Is of concern to LeRoy.
7. Presence of Lewis Acid forming constituents was described by GeorgeHBrake to be of extreme importance in developing flame retardance. George Drake addressed a recent flammability seminar in New Orleans.
8. Plastlsol viscosity stability of Santlelzer 148, better than Santlcizer l4l, is very Interesting to Gene Condon. He Indicated belief
I that the earlier use of Santlelzer l4l would have led to problems because of viscosity stability In a prolonged plant run. He agreed that the use of a faster fusion system was a definite asset In the production, and that attempts to achieve faster fusion with adequate viscosity stability were desirable. Adequate viscosity stability remains unquantified.
9. lab trials of chlorinated paraffin are being considered. Advantages such as low cost and disadvantages such as required stainless steel
I storage and plumbing, more loosely bound chlorine with possible I skin lrrltatiin and chloracne, were discussed. Interest In chlori I nated paraffins was at least dampened. The thought of loose chlorine I and HC1 scared LeRoy. I 10. Lab trials with Santlelzer 146 and with Santlelzer 160 as a partial I DOP replacement will begin Immediately.
MONS 080383
-3-
FORWARD FIAHS
Lee, as you are well aware, these people move frustratingly slow. Unless otherwise motivated, I can foresee that LeRoy and Gene may go through a three month lab program evaluating 16 formulations and then through patch testing everything before making another plant trial.
Our objective should be that LeRoy and Gene follow a brief lab program which entails finding the best ratio of DOP/Santiclzer 148/secret additive, followed by an Immediate plant trial. Timing on the plant trial could be Christmas. Patch testing, which will merely confirm what is already known, would best be done on plant-produced material.
You can best pursue, with LeRoy, speeding up what could otherwise be an Interminable program.
Call Follow-Up:
1. Send LeRoy Information concerning Identification of combustion products.
2. Forward details of repeated Insult patch testing of Santlcizer 148.
3. Forward reference to encyclopedia article on flame retardance.
4. Send Gene Condon articles relating to theoretical aspects of plasticization.
LDP/ce
L. D. PRESS
MUNS 0B038'*