Document NGXqD39NRYMe308bwLDOOV8dg
PYDRAULMC
Fire-Resistant
Bulletin No. IC/FF-48
Hydraulic Fluid
...For Mining Equipment
0096944
Monsanto
TOWOLDMON0022121 WATER PCB-00006590
I
NOTICE: "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any pat ent. MONSANTO MAKES NO WARRANTIES AS TO THE FIT NESS FOR A PARTICULAR PUR POSE OR MERCHANTABILITY OF ANY PRODUCT REFERRED TO, no guarantee of satisfactory results from reliance upon con tained information or recommen dations, and disclaims all liability for any resulting loss or damage." * "NOTE: Materials designated 'fire resistant' generally are more dif ficult to ignite, or once ignited, burn at a slower rate than cor responding conventional materi als. This term does not mean that fire resistant materials will not burn. However, when proper ly used, Monsanto's fire resistant PYDRAUL HYDRAULIC FLUIDS are useful in helping customers meet their fire safety require ments.1'
TOWOLDMON0022122 WATER_PCB-00006591
A high-performance hydraulic fluid for safer hydraulic operation with minimum maintenance
Pydraul MC fire-resistant* hydraulic fluid was developed specifically for use In mining equipment. It is a phosphate-ester based formulation containing no water. It meets the fire resistance requirements of the U.S. Bureau of Mines Schedule #30. Equally important, field experience since 1972 shows that Pydraul MC fluid offers the following operating advantages:
Reduced Fluid Maintenance Unlike water-based hydraulic fluids that are oil emulsion or glycol solutions-- Pydraul MC does not lose water by evaporation to change com position and viscosity.
Eliminates Hazards From Spillage Water-based fluids that evaporate off their water component can leave behind flammable residues in reservoirs, spill pools or crevices.
Operates At Higher Temperatures & Pressures Pydraul MC has excellent viscosity characteristics and a high degree of lubricity that permits efficient hydraulic operation at pressures up to 5,000 psi.
Gives Equipment Protection From Corrosion Pydraul MC fluid does not create a rust-promoting environment in operating equipment. It is chemically stable to help eliminate corrosion problems.
Trademark of Monsanto Company
Monsanto's development of fire protection for industrial hydraulic operations began with the first Pydraul fluid in 1951. Pydraul fluids have since provided industry with millions of machine hours of safe operation.
Pydraul MC was designed to
enable ore and coal mine operators meet the current safety legislation that requires a fireresistant fluid in unattended equipment and either a fire-
resistant fluid or suitable fire suppression devices in attended equipment. The initial cost and maintenance of fire suppression devices may show that a stable fluid such as Pydraul MC would be the most economical choice in the fong run.
Pydraul MC is a dependable hydraulic fluid for safer operation
of above- and below ground equipment with minimized maintenance. It may be considered for use in the hydraulic systems
of the following:
Power Shovels & Draglines
Blasthole Drills
Bulldozers & Rippers
Tractors
Scrapers & Graders
Crushers
Ore Feeders
Trucks
Jumbos
Ore Drills
Mechanical Loaders &
Scrapers
'
The following pages give data that illustrate the typical prop
erties and performance of Pydraul MC as measured by standard test procedures used to describe hydraulic operation and fire resistance:
TOWOLDMON0022123 WATER_PCB-00006592
Typical Physical Properties*
Appearance Specific Gravity 25/25C. Density at
140F. 77F.
Neutralization No. (mg KOH/g) max. Moisture (max.) % Viscosity
Centistokes @ 40F.
@ 100F. @ 210F. SSU @ 40F. @ 100F. @ 210F. Pour Point
Coefficient of Thermal Expansion per F. Specific Heat BTU/lb./F. @ 77eF. Thermal Conductivity BTU/hr./ft./F. Solubility in Water
Clear Green Liquid 1.096
1.075 grams/ml. 1.100 grams/ml. 0.30 0.15
1250 cs 69 cs 6.9 cs
5600 SSU 320 SSU 48 SSU -- 10F.
0.00034 0.39 0.0728 Negligible
'This data is based upon samples tested in the laboratory. It is not guaranteed for all samples. The properties listed above, in addition to varying from sample to sample, are subject to change from time to time due to process modifications and improvements. For complete sales specifications write to Monsanto Company at the address listed in this bulletin.
00 wT
o
5
3
<
DC
a
> x
TOWOLDMON0022124 WATER_PCB-00006593
Viscosity of Pydraul ' MC In Centistokes
Pump manufacturers recommend ed operating range between 13 cs. and 1000 cs,
PYORAUl MC
TEMPERATURE, DEGREES FAHRENHEIT
Ss
mas
fft |O
TOWOLDMON0022125 WATER_PCB-00006594
Typical Performance Properties**
Foam Test (ASTM 0 892) Sequence1,2, 3 Rust Test (ASTM D 665) Sequence A Hydrolytic Stability Test (MIL-H-19457) Oxidation and Corrosion Test (FS791-3508).
(168 hr., 250F., 5 1 air per hr.) Metal Weight Changes, mg/cm2 Magnesium Aluminum Cadmium Steel Copper
Acidity Increase, NN 100F. Viscosity Increase, %
Pass Pass Pass
-0.01 +0.05 -0.01 +0.01 - 0.02
2.56 13.1
Compatibility With Materials
Metals Paints
Other Fluids
Pydraul MC is compatible with all the commonly used metals of construction.
Cured epoxy, phenolic, polyurethane and nylon based paints are satisfactory. INTERIOR SURFACES ARE PREFERABLY LEFT UNPAINTEO.
Pydraul MC is miscible in all proportions with the Pydraul E and Pydraul C Series of fluids. It ie essentially Insoluble in water.
Packings, Seals,
Materials compatible with Pydraul MC are necessary for
Hosesand Bladders dynamic or moving seals. For static seals they are preferred
but not essential.
Recommended
Marginal**
Unsatisfactory
VITON
BUTYL5
BUNA-N
NYLON
EPR
NEOPRENE
TEFLON 1
NATURAL RUBBER
FLUOREL*
SLICONE
'Tr*fl#mirk o E. I. Du Pont. -Trademark of Thre-M Company. JTrademark of Ertjsy Chemical Co.
"Although genaraily classified aa marginal with Pydraul fluids, butyl and EPfl (eihylana prooyiana rubber) have proven aatiafactory in equipment operating under certain condition! of temperature, fluid cleanliness, maintenance, etc- For best service under genera) all-around operating conditions, elastomers of Viton. Nylon. Fluorel, Teflon, and silicone are suggested.
Fire Resistance Properties
Flash Point Fire Point Autogenous Ignition Temperature (ASTM D 2165) Factory Mutual High Pressure Spray Test
(Test fluid sprayed @ 1000 psi through orifice, passing through llama of propane torch.) Factory Mutual Hot Channel Test [Test fluid sprayed @ 1000 psi through orifice, onto hot channel Iron @ 1300F.) U.S. Bureau of Mines Approval Schedule 30
0096949
475F, 525F. 800F. Pass Extinguished in less than 5 sec. after torch removed. Pass
Yes, Number 30-6
Fire Reeletance Advantages of Pydraul
Pydraul fluids protect hydraulic equipment and personnel with permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue- During their many millions of machine hours of use. Pydraul fluids have been accidentally sprayed over molten metal, through electrical arcs, into flames and sparks without disaster. They pass all of the Important Ignition tests for fire resistance.
TOWOLDMON0022126 WATER_PCB-00006595
Converting Mining Equipment Hydraulic Systems to Pydraul MC
Regardless of the type of hydraulic fluid being used, converting a system lo Pydraul MC is easy. Virtually every type of equipment that uses fireresistant hydraulic fluid has been converted to Pydraul phosphate-ester hydraulic fluids. Most equipment manufacturers are experienced in conversion to Pydraul fluid and should be consulted.
If changing seals is necessary, equipment manufacturers can recommend which to change, and many carry a supply of compatible seals. Laboratory tests and opera tional experience show Viton, Teflon, and silicone to be the preferred elastomers.
To replace other fluids which are compatible with Pydraul and where compatible seals are already In the system, it is only necessary to add Pydraul MC as make-up fluid. It is not necessary to drain or clean. However, when converting from petroleum oils, non-compatible synthetic lluids, water-glycol fluids, or water-ln-oll emulsions -- the following steps are recommended. These conform to USA Standard B93.5 -- 1973.
Changing from Petroleum Oil
1. Completely drain and clean the system. Small amounts of oil will not interfere with the performance of Pydraul, but resistance to fire is reduced by the amount of oil left in the system.
2. Drain and blow out pipelines. Manually clean valves and reservoirs.
3. Open or remove-and-drain all valves. Replace gaskets, packings, and seals with compatible materials. It is particularly important to change dynamic seals. Static seals do not necessarily have to be changed if they are not leaking. Non-compatible static seals can be replaced when the component is disassembled for maintenance.
4. Remove pumps, accumulators, and cylinders, if necessary, for draining. Replace packings, seals, gaskets, and bladders with materials com patible with Pydraul.
5. Check component functions before the system is closed and fluid is added. 6. If the system cannot be completely drained, it may have to be flushed out with a small amount of Pydraul.
Changing from Water-Glycol or Water-in-Oil Emulsion 1. Drain and clean system thoroughly. Remove all traces of water. Empty all lines and low points or dead pockets in components.
2. Clean with steam or warm water. Follow by blowing with dry air.
3. Check sealing materials, hoses, and accumulator bags. Replace if necessary with compatible materials.
4. Install a minimum charge of Pydraul hydraulic fluid and operate the system from 16 to 24 hours. During this period, inspect the reservoir. If water or other contaminants float to the top, remove by skimming.
5. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all Isolated points or parts which do not drain back to the reservoir. If water is apparent in fluid clinging to walls, wipe down all accessible parts.
Ask the Monsanto fluids specialist for suggestions and assistance. He may be reached by phoning the nearest sales office listed on the back cover.
Toxicity and Safe Handling
Animal studies Indicate that Pydraul MC can be classed as practically non-toxic when con sidered as an industrial fluid. It is non-irritating when the skin is exposed to the fluid.
In case of skin contact wash off with soap and water as a hygienic procedure. In the case of eye contact flush with copious amounts of water.
Due to its low order of toxicity, Pydraul MC requires no special handling precautions.
0096950
TOWOLDMON0022127 WATER_PCB-00006596
CUSTOMER SERVICE CENTERS
AKRON, OHIO 44313 260 Springtide Drive Montrose Development Park Tel (216) 666-4111
ATLANTA, GEORGIA 30339 320 Interstate North Parkwey Suite 500 Tel. (404) 432-7111
BOSTON, MASSACHUSETTS 02149 Everett Station To/. (617) 387-S010
CHICAGO, ILLINOIS 3158 Des Plaines Ave. Dea Plaines. Illinois 60018 Tel. (312) 296-6688
CINCINNATI, OHIO 45236 8041 Hoabrook Road Tel. (513) 984-1100
DETROIT, MICHIGAN 500 Northland Towers West Southfield, Michigan 48075 Tel. (313) 357-0910
HOUSTON, TEXAS 77027 1301 Post Oak Tower 5051 Westheimer Road Tel. (713) 621-9550
LOS ANGELES, CALIFORNIA 1401 Dove Street Newport Beach, California 92660 Tel (714) 833-9150
NEW YORK, NEW YORK 10036 1114 A venue of the Americas Tel. (212) 764-5000
ST. LOUfS, MISSOURI 63166 800 N. Lindbergh 8/vd. Tel. (314) 694-1000
SAN FRANCISCO BAY AREA 2710 Lafayette Santa Clare, California 95052 Tal. (408) 243-0414
WILMINGTON, DELAWARE 19810 Suite 204, Bancroft Bldg. 3411 SHveraide Road Tel (302) 478-4600
Monsanto
Monsanto Industrial Chemicals Co. A Unit of Monsanto Company 800N. Lindbergh Blvd., St. Louis. Mo. B3166
>
0096951
J-3609 0175-92 Litho in
TOWOLDMON0022128 WATER_PCB-00006597