Document NGVwKXX7j95oXn1ZBJqDpxOKy

Mrrisanto |I I \b J ^ 1 I 1"* \ "` ' ` JL- r,` KoLJ_l L '_,?1'_7! January 1.-, J '17.1 _ adoqxn ir,] c_-__astm ir:nioi >s PGD 12/11/1] K-ir.o to RCK P. C. Br-mynus n?su , w. ---- >R. r.. M. w. 1J. T. C. R. Pich.u 1 - n. Mure', 0. fir. r end 5 , Ti'Ckef - 5 S-- J T * i w. Di'-'ti-j'- h/1 . i' f 1 ( l. Sr-CO'lt : li. PapdtKorqi - jpn; 5 , Bergen - H? L. Coe.so je -* P y '* i Pal on - BiMl The attached method, 71-11A. should be suitaLlc ls writ-ton : or measureMiciit of ponta and nexa isomers m Arcelor 1016 i or specificaUon purposes . Dro. Munch and Emery recommend i.i< u thin procedure be submitted m ASTM Committee D-27. Pins write-up entitled "Gas Chromatographic Determination of T1ontaund Hexa-Chlorobiphenyls m Aroclor 1016 and Arcelor lo.A?" wa^ prepaied for distribution outride Monsanto. Kc have no method suitable for setting a strict limit against the highly toxic poJychlorodibenzofurans in foreign PC' materials. The attached method, 70-23, entitled "Determination of Chlorinated Dibenzofurans in Aroclor Products'' hnn boon used in cur laboratories by Drs. Dietrich and Mieure to icier t; f-y aim to naUe a rough estimate of dibenzofurans. It could oi ktj tttn as an identification proceonre only but not ds a rout me quantitative method furthermore, this procedure requires c mJ spectrometer to identify chromatographic peaks as dibcncefur r;. This will ] immediately rule out a majority of ieboi a tcri rs v.,`-,u use ASTM methods. Additional research work will be needed to develop the gas ohromntoca aohv/mass spectrometry tecon iqM-' mto a sufficiently Peculate method. This will tare $2,000+ with i 50/00 chance of success for measurement within +50?, relative in the 0-25 pom ranqe. Please advise if you feel that additional effort is justified on either writing up an identification method or researching a quantitative method for the dibenzofurans. db Attachments R. E. Keller HONS 201718 SpecLrnscopv Method 70-23 Job No. 8 V 0 3 2 G 9 DETERMINATION 0!` CHLORINATED D I BEN ZOl'URAN S IN AROCLOR PRODUCTS introduction Low levels of polychlorinated dibenzofurans have been indicated in competitive polycnlorinated biphenyls (PCh's), but not in Aroclor. Because of the reported high toxicity of polychlorinated dibenzofuiiins, a sludy was> undertaken to determine if these, or related, compounds exist as impurities in our product. PRINCIPLE A direct gas chromatographic determination of these Impurities is not possible because of interfering PCB cowponent3. However, if the Aroclor is eluted vith hexane through a colunn containing FloriuiJ odsorbant, the PCB can be removed, leaving any polar oxygenated compounds adsorbed on the Florisil. These oxygenated materials can then be eluted by a more polar solvent, such as diethyl ether. A procedure based on these principles is desci'ibed below. Certain polychlorinated naphthalenes and phenanthrenes or anthracenes are also detected by this procedure. REAGENTS AND APPARATUS Hexane - Mallinckrodt Nanograde. Diethyl Ether - Anhydrous Mallinckrodt reagent grade. Two solutions, , one 5% and the other 252 by volume, of ether in hexane,were prepared . Florisil - Fisher, 60-100 mesh, heated at 130C for 4 hours and stored in a desiccator. Sodium Sulfate - Anhydrous Fisher certified A.C.S. grade, heated at 400*C for 1 hour and stored in a desiccator. Liquid Chromatography Columns - 3.6 cm i.d. X 50 cm long Pyrex with Teflon stopcocks. . Gas Chromatograph - A Hewlett-Packard 5750 with a nickel electron capture detector. The column is 1/4" X 8' 1 glass, packed with 42 XE-60 on 80-100 mesh H.P. Chromosorb W. The helium flow rate i6 60 ml/min, the 902 argon, 102 methane purge flow is 120 ml/ min, and the oven temperature is 210*C. Mass Spectrometer - A Varian MAT CH 4B interfaced with a fritted glass separator to a Hewlett-Packard 5750 gas chromatograph equipped with a flame ionization detector. MONS 201719 Method 70-23 1* a ft >> 7 Sample Concentrator - 500 ml Kunderna-Danish evaporative concentrator with a 3-ball Snyder column and a 5 ml receiver (Ace Glassware). EX P F ft I M 1 NTAL A. Column P reparation A small amount of glass wool is placed in the bottom of the column, which is then half filled with hexene. Next, 180g of dry Florisil is poured into the column and allowed to settle. Three grams of sodium sulfate is added to the top and one liter of hexane is allowed to elute through the column at a flow rate of about 10 ml/min. The liquid level must not be allowed to drop below the top of the packing. The column can be stored until ready for use as long as the hexane level is maintained above the packing. B. Column Separation An accurately weighed sample of Aroclor, about 0.5g, is dissolved in 20 ml of hexane and poured onto the head of the column. The bulk of the FCB is eluted with 2500 ml of hexane, using a 10 ml/min flow rate. This solution is discarded. Next, 80 0 ml of 5 7. diethyl ether is eluted through the column and the eluate discarded. Finally, 800 ml of 2 5 X diethyl ether is eluted. Two successive 400 ml portions arc collected, starting as soon as the 25% ether is added. These 400 ml portions are saved for further characterization. C. Concentration of the Samples Each 400 ml sample is added to a Kunderna-Danish evaporator. The apparatus is placed in a 90"C water bath and heated until the volume has decreased to.about 5 ml. The receiver is dis connected and the solution is further concentrated to 3.0 ml by passing purified nitrogen over the surface. Alternatively, the entire concentration can be carried out by evaporation with nitrogen passed over the liquid surface; this is time consuming and some sample is lost on the container walls. 0, Standardization of the Electron Capture GC A 1 pt aliquot of a 1.15 ng/y solution of 2, 3, 7, 8-tetrachlorodibenzo-p-dioxin (TCDD) in hexane is injected into the GC. The chromatogram is recorded and the height and retention time of the peak is measured. TCDD was used as a standard because of the lack of a suitable polychlorinated dibenzofuran standard. HONS 201720 Method 70-2i ram 3 E. Quantitation An appropriate aliquot (0.5-5 li) of each concentrated cample solution is injecLed into the electron capture GC. The chromatogram is recorded and the height and retention time of each peak is noted. The concentration of each species in the Aroclor, expressed as ppm TCDD, is Cone(ppm) * 1-15 samp1 e X Peak Hcight(Unk) ,, Peak Height(TCDD) Volume In] fc t Pd ( H'_C iO Volume lnjccLed(lnk) wt (g) Retention Time (Unk) Retention Time (TCDD) F, Identification Excess solvent is evaporated from the sample so that only about 10 p remains. This entire amount is analyzed as one aliquot bv GC/MS using standard techniques. The mass spectra of each Aroclor and likely impurities exhibit prominent molecular ion peaks. The number of chlorine atoms per molecule can be calcu lated from the isotope ratio of the molecular Ion. Components identified in this manner can be related back to the chromato gram used for quantitation. Polychlorinated naphthalenes and phen <int lire nes or anthracenes have also been observed. We have not verified the quantitation of this procedure for these polynuclear aromatics. db Monsanto Company Organic Chemicals Division Applied Sciences Section S t. Louis, Missouri ' 12/70 - J. P. Hieure, M. W. Dietrich HONS 201721 Physical Che'ni.3ry Method Mo. 71-11A Job No. 134 br2 2 GAS CHROMATOGRAPHIC DETERMINATION OT PENTA- AND IIHMACULOHOMPHENYLS IN AROCLOR 1016 AND AROCLOR 17 4? PURPDSE OF ANALYSIS This is a rapid, simplified method to be used to determine the level of high boilers (mainly pentachlorobiphenyls) in Aroclor 1016 or similar products. It is not intended for general analysis of clilcrn nated biphenyl mixtures. CHROMATOGRAPHIC CONDITIONS Instiument: Perkin-Elmer 600, Hewlett-Packard 7624A or Equivalent 'ype Detector: name ionization Column: 50' x 0.02" I.D. TRAP S.C.1 T. (Support-Coated Open Tubular) Capillary (Perkin Elmer Part No. 008-0804) Column Temperature: 220C Flow Rates Detector Block Temperature: 300C Injection Port Temperature: 320C Sample Volume injected: 0.005 ml Split 25 to 1 Column Helium: 8 nil/min (7 P3IG) Inlet Splitter: 21C ml/mm Auxiliary or Make-up Helium: 50 ml/ mr Hydrogen: 50 ml/min Air: 400 ml/nnr. RETENTION TIMES (UNCORRECTED) OP COMPONENTS SI'PARATED (CHROMATOGRAMS ATTACHED)" " Biphenyl, Mono-, Di-, Tri- and Most Tetra-Chlorobiphenyls (1.0 to 5.0 min): High Boilers (Mostly Penta- and Hexa-Chlorobiphenyls) (5.5 to 11.2 min). CALCULATION TECHNIQUE Peak area normalization. The lack of pure knowns prevents the accurate determination of response factors (area correction factors) for the in dividual components. Therefore, the specification for Aroclor 1016 is simply based on area percent of total high boilers. PRECISION Reference samples* of Aroclor 1016 (Drum 2) and Aroclor 124? (Lot KK 491) were analyzed in duplicate on the two instruments listed using both the Disc chart integrator and an electronic integrator (Infotromcs CRS-100 on the Perkin-Elmer 800 chromatograph and Hewlett-Packard 3370A on the Hewlett-Packard 7624A chromatograph). The same column was used in both instruments. Results reported as Area % High Boilers: HOMS 201722 Method No. 71-11A Page 2 Aroclor 1016 (Drum 2) ; Chromatograph Pcrkir.-Elr.ier 800 hew]ett-Pnckard 7624A Aroclor 3742 (hot KK 491): Pcrkin-Elmcr 800 I!ewIctt-Packard 7624A Method of Integration Disc Chart Jnfotronics CRS-100 Ilewlett-PacKard 3370A 0.30, 0.27 0.30, 0.30 0.23, 0.21 - - 0.27, 0.28 5.88, 5.78 6.14, 6.32 6.22, 5.94 - 6.63, 6.50 ^Portions of these samples are available to laboratories that are sotting up this method for control of Aroclor 1016 manufacture. Monsanto Industrial Chemicals Company Applied Sciences Section St. Louie, Missouri 10/71 - G. M. Gasser, E. M. Emory MONS 201723 MONS 201724 1-1 ewlerff-A Pdrltin - : lw,cv ^60 MONS 201726 START X Z0DO (O.OoS ml. A fo c U r IPJfZ b + !<k tfl) H eu I eft- - 7C.ZH A O.OOS"rw(. A ^cJor fZ 'Z ( U f k K `t f l ) START---------- * /0 Hj{\ Boi Uns I lI * IX. lo ^ 4 H Mi mCrer z HONS 201727 V*S rtf