Document NGRKeYdd13VeVMaLV7xBkX1wD

Heaters, Water McDermott Water Heaters, Inc. 101 Park Avenue New York City SOLD BV JOBBERS AND BOILER MANUFACTURERS Installation--Minimum cost and time required for the installation of McDermott Water Heaters are outstanding features. The reason is as follows: A clearance hole (not threaded) is cut in a few minutes. Two holes are drilled alongside and tapped %/%" (pipe size). The stud bolts furnished are placed in the two holes and when the nuts are on the job is done. It's a flange connection. 1 gasket (also serves as a template), a thermometer, 1 pressure relief 125 lbs., complete instruc tions and blue print of connections between boiler and tank accompany each shipment. Specify the number of longest units 2" shorter than the longest boiler tubes, that will total the tank requirements. For Tankless Heaters specify 4 V4106 or 3, if V4108, M4210 or M4212 units Ratings When Used With Tanks Size Length Capacity, Gallons Tank Con nections Inches V4103 V4I06 V4I08 M42I0 M4212 V O' 6' O' 8' O' 10' O' 12' O' 150 245 350 550 800 w M/' 1%' 2' 2' Ratings based on 100 temperature rise in three hours and delivery is assured as rated. are used. They connect in series, 1)4" pipe if V type, and raise 9,000 G.P.H. 140 F. If M type, no .larger than 2" pipe is used to series the units which will raise 19,000 G.P.H. 140 F. Both ratings at 50 lb. pressure and 200 F. boiler water. McDermott Tankless units enable you to specify any tubular boiler for instantaneous water heating. Tested at 450 lbs. and Guaranteed for one year. Sixty-six Questions and Answers-- A letter size book that helps solve water heating problems, should be in your files. The First Submerged Unit in New York was installed by McDermott. McDermott patented features are not procurable elsewhere. heater control AND CLEAN-OUT VALVES HOT WATER SUPPLY 'TO BUILDING HOT WATER RETURN FROM BUILDING BOILER WATER TEMPERATURE FOR SUMMER FIRING 702 Heaters, Water The National Pipe Bending Co. 104 River Street, New Haven, Conn, Atlanta, Ga. Baltimore, Md. Boston, Mass. Offices in the Following Cities: Butts, Mont. Chicago. III. Cincinnati, Ohio Cleveland, Ohio Denver. Colo. Duluth. Minn. Los Angeles, Calif. Memphis, Tenn. Minneapolis, Minn. New York, N. Y. Philadelphia, Pa. Pittsburgh, Pa. PRODUCTS--Water Storage Heaters, Instantaneous Water Heaters, Swimming Pool Heaters, Feed Water Heaters, Coal Burning Tank Heaters, Oil Burning Tank Heaters, Special Heaters, Coolers for all purposes, Colls and Bends of Pipe and Tubing. A line of well built heaters stocked in sizes and capacities most generally used. Equipped with U-Betad heating element of Furnished in Water or Steam Tube types for gravity or pressure circulation. Anaconda Copper. Steel Tank. Im Heats water as it flows either con proved flanged T cover gives unrestricted tinuously or intermittently. Built for flow area for entering steam. Tested to steam pressures up to 75 lb. per sq. in. 100 lbs. working pressure, 150 lbs. hy U-Bend copper tubes through which the T drostatic pressure. For installations re quiring heaters other than listed below use water passes are fitted into a cast iron or regular National individually engineered steel shell through which the steam for heaters described in Bulletins No. 55, 57, heating is passed. Made in sizes from 210 65. Our engineering service is at your to 12,000 gal. of hot water per hour at command. temperatures from 40 to 180 F. DATA to be used with RED HEAD Heaters SHELLS (Horizontal) Manhole 11* z 15' in all aizes above 18'. HEATING ELEMENTS Temperature range based oo beating water from 50 degrees to 180 degrees F. at steam pres sure 0 to 51b*. No. Gallons Size Thickness Thickness Weight One Filling of Shell of Shell of Head of Shell No. Gallons per Hour Smallest Shell into which element goes Inches Weight of Element Lbs. A 80 I8x 72 Hi Vb 380 NS-I 80 I8x 72 85 B 141 24* 72 Hi % 530 NS-2 100 I8x 72 88 C 220 30s 72 Va Hi 670 NS-3 150 I8x 72 % D 310 36x 72 V* Hi 1020 NS-4 200 18x 72 117 E 365 36x 84 Vi Hi 1130 NS-5 250- I6x 72 122 F 475 36x108 Vi Hi 1350 NS-6 300 I8x 72 185 G H 575 42x 96 645 42x108 Hi Hi '<AA 1750 1900 NS-7 NS-8 350 36x 84 400 36x 84 189 195 I 720 42x120 Hi Vi 2050 NS-9 450 42x % 205 J K 860 42x144 940 48x120 ,`J* Hi VVii 2350 NS-10 500 42x 96 2410 NS-11 600 42x 96 210 260 L 1130 48x144 Hi 'A 2770 NS-12 700 42x108 270 M 1300 48x168 Hi Vi 3100 NS-I 3 600 42x108 285 N 1425 ' 54x144 ` % Hi 3750 NS-14 900 42x108 343 \ 0 1665 54x168 Vs Hi 4300 NS-I 5 1000 42x108 357 P 2000 60x168 Hi Hi .5200 NS-16 1250 42x108 440 Q 2460 72x144 Vi % 6500 NS-17 1500 42x108 468 R 2875 72x168 Vi ' Vt 7600. NS-I 8 1750 42t!08 575 NS-19 2000 42x108 620 1 NS-20 2500 42x106 755 How to Specify NATIONAL RED HEAD STORAGE HEATERS- . Combine the number of the required storage and heating elements. To heat 1000 gallons per hour with a storage capacity of approximately 500 gallons, refer to tables above and spefcify one National Red Head Heater NS-15-F. 703 A