Document NGR9721GwdwvVZxGOR4BENdeg

Heating Ventilating Air Conditioning Guide 1938 handles are often supplied to indicate the relative opening of the valve in any position. Standard roughing-in dimensions for angle-type valves are given in Table 12. Automatic control of steam supply to individual radiators can be Table 11. Proposed Dimensions of Steel Welding Neck Flanges for Maximum Steam Service Pressure of 300 Lb per Sq In. (Gage) at a Temperature of 750 F Chapter 18. Pipe, Fittings. Welding for use in hot water heating systems are of less complex design, one type consisting of a simple butterfly valve, and another of a quick opening type in which a part in the valve mechanism matches up with an opening in the valve body. In one-pipe steam-heating systems, automatic air valves are required at the radiators. Two common types of air valves available are the vacuum type and the straight-pressure type. Vacuum valves permit the expulsion of air from the radiators when the steam pressure rises and, in addition, act as checks to prevent the return of air into the radiator when Table 12. Standard Roughing-in Dimensions Angle Type Valves Nominal Pipe Size *2 2V 3 3V 4 5 6 8 10 12 14 0. D. 16 O. D. 18 O. D. 20 0. D. 24 O. D. DiAM. OP Flange Thick- I ness op Flange Min. Diam. OP Hub Hub Diam. Beginning op ChahfIiE 0 0J E 6V m 8M 9 10 11 12H 15 17H 20H 23 2SV 28 30V 36 Vs 3^6 1 3% mm Ws 5K m 1 5X m7 iKe sv m 10M m l2Vs 2 UX V/s m 22X% 19 21 2V. 23H 2X 21Vs 2.38 2.88 3.50 4.00 4.50 5.56 6.63 8.63 10.75 12.75 14.00 16.00 18.00 20.00 24.00 Length Thru Hub Y 2;% 3 3V 3Xs 3Vs 3Vs 3Vs m 4H 5ys SVs SX 6X m 6Vs Diam. fob Standard Pipe A 2.07 2.47 3.07 3.55 4.03 5.05 6.07 7.98 10.02 12.00 13.25 15.25 17.25 19.25 23.25 Diam. fob Extra Strong Pipe Diam. op Bolt Circle No. OP Bolts A I.94 2.32 2.90 3.36 3.83 4.81 5.76 7.63 9.75 II.75 -- 5 s% 6Vs m m 9K lo^g 13 15H 17M 20K 22V 24X 27 32 ' 8 8 8 8 8 8 12 12 16 16 20 20 24 24 24 Size o? Bolts % X X X X X X Vs 1 IVs IV ix m m IV . *For sizes below 2 in. use dimensions of 600 lb flanges. ^ All dimensions given in inches. A raised face of Hs in. is included in thickness offlange minimum. It is recommended that the taper of the hub should not exceed 6 deg for a reasonable distance back of the chamfer in order to reduce the heat transfer while welding. effected by use of direct-acting radiator valves having a thermostatic element at the valve, or near to it. The direct-acting valve is usually an angle-type valve containing a thermostatic element which permits the flow of steam in accordance with room temperature requirements. These valves usually are capable of adjustment to permit variation in room temperature to suit individual taste. Ordinary steam valves may be used for hot water service by drilling a iij-in. hole through the web forming the seat to insure sufficient circulation to prevent freezing when the valve is closed. Valves made particularly Size op Valve V X i IX IV 2 Tolerance Dimension A Steam and Hot Water Angle Valves and Union Elbows Effective Januabt 1,1926 Dimension a Modulating Valves Effective Januabt 1,1926 2X 2X 2X 2X 33 3V 3V 3myXe 3mX Ys Dimension A Return Line Vacuum Valves Effective January 1, 1923 3X -- All dimensions given in inches. Connecting ends shall be threaded and gaged as to threading according to the American (Taper) Pipe Thread Standard, A*S.A. No. B2--1919. . The standardization of the Roughing-in Dimensions of Angle Steam and Hot Water, and Modulating Radiator Valves was made possible by the cooperation of the Manufacturers Standardization Society of the Valves and Fittings Industry. a vacuum is formed by the condensation of steam after the supply pressure has dropped. Ordinary air valves permit the expulsion of air from the radiator when steam is supplied under pressure, but when the pressure dies down and a vacuum tends to be formed the air is drawn back into the radiator. A system operating continuously or intermittently and supplied with vacuum valves will generally heat more quickly than one provided with non-vacuum air valves; thus, it will effect considerable economy of fuel because the idle period during which no heat is delivered is shortened. In those cases, where a system is equipped with vacuum air valves and which has been cold for several days, the system will probably have an 373