SUPERSTRUCTURE WORK LAKE CHARLES PLANT - RIVERSIDE STATION - UNIT 3
PROJECT NO. P-799 PITTSBURGH PLATE GLASS COMPANY - CHEMICAL DIVISION
SECTION 5 - ASBESTOS-CEMENT SIDING
5-01. SCOPE This section of the Specification includes requirements for the following, as indicated on the drawings, as hereinafter specified (under the Article numbers indicated), or as required to properly complete the Work:
5-02, General Requirements for Asbestos-Cement Siding and Roofs 5-03. Detailed Requirements for Asbe.itos-Cement Siding and Roofs 5-04. Samples Required
5-02. GENERAL REQUIREMENTS FOR ASBESTOS-CEMENT SIDING AND ROOFING A. Structural Requirements:
a. Wind Loads: Height Zone in Feet
Inward and Outward Wind Pressure in Lbs. Per Sqjare Foot
(1) Less than 30.........................................................................
25
(2) 30 to 49................................... .................... .........................
35
(3) 50 or over..-........................................................................
45
b. Fasteners provided shall be designed td withstand these loadings without exceeding the maximum allowable unit stresses for such fasteners.
B. Thermal Properties:
a. Overall coefficient of thermal.transmission U for insuleted roofing shall not exceed 0.280 Btu/hr/sf/F in still air.
b. Submit test data from recognized tee ting laboratory to substantiate Contractor's claims as to thermal pioperties of his constructions; in lieu of this, Contractor shall arrange, without cost tc Purchaser, to conduct such tests as may be directed by Consulting Engineers to verify such claims.
C. Weathertightness: All completed siding shall be WATERTIGHT AND AIRTIGHT to provide a completely weathertight and/or dust-tight installation.
D. Girt Alignment: Prior to erection of siding, check accuracy of alignment
of wall girts to see that they are within tolerances allowable for installation
of siding they are to support. Immediately report any inaccuracies found
to Consulting Enginees so inaccuracies can be rectified before siding and/or
roofs are erected.
i
5-1 I BB 0012259 <
SARGENT & LUNDY
ENGINEERS CHICAGO
K-2342
E. Lap Lines: Line up all around for sidirg. Provide uniform straight lines for roofs.
F. Field Painting for Concealed Surfaces: This work will be performed by Sline Industrial, Painters, Inc., and will include cleaning and painting, for all surfaces of structural steel and miscellaneous steel (other than galvanized surfaces) which yill be in contact with, or madq:inaccessible by, siding, roofs, flashings, etc,. Do not install these materials in ar.y area until the required-painting hqs been completed, irspected and approver.
G- Cleaning of Siding and Roofs:
a. Clean all exposed faces of siding anc roofs of labels, dirt, streaks, caulking or sealing materials, undue discolorations, etc., and provide at least a-dry wipedown at time of erection.
b. All exposed faces of siding and roofs, just prior to acceptance of the WORK, shall be. completely satisfactory in appearance to Consulting Engineers. Any defects in appearance, due to Contractor, shall be remedied at Contractor's expense, as required.
5-03. DETAILED-REQUIREMENTS FOR ASBESTOS-CEMENT SIDING AND ROOFS Detailed' requirements for siding, roofs and all components sad accessories shall be as specified in the following tables:
A. Table 5-1 - Requirements for Siding and Roof Components.
B. Table 5-2 - Requirements for Siding and Roof Accessories.
C. Table 5-3 - Requirements for Siding and Roof Fasteners.
D. Table 5-4 - Spacing of Siding and Roof Fasteners.
TABLE 5-1 REQUIREMENTS FOR SIDING AND ROOF COMPONENTS
Item
Requirements
1. Uninsulated
Siding and .
Roof
%i
A. Material: Corrugated asbestos-cement, ASTM C221, Type A (Standard)
B. Manufacturers: One of following types and makes: a. Transite Corrugated.............. Johns-Manvillc b. Corrugated Asbestone 400.. National Gypsum Company c. Careystone Corrugated.......... The Philip Carey Mfg. Co.
C. Sheets: a. Width: 42" b. Overall Depth: Approximately 1^" c. Material Thickness: Approximately 3/8" d. Weight: Approximately 3-3/4" to 4 psf
s e. Corrugations: 4.2" pitch, 10 per sheet D. Side Laps: 4.-2" (one corrugation) E. End Laps: 6" minimum F. Installation Method: Straight line, using cut corners
5,,2 Table 5-1 continued next page
1 BB 0012260 1
SARGENT 5: LUND\
ENGINEERS CHICAGO
if* TABLE 5-1 ROOF COMPONENTS, Cont.
K-2342 R
Item . 2. Insulated
Roof
i
1
.! Requirements
A. Material;,- Asbestos-cement, as follows;
a. Exterior Sheet: Corrugated, ASTM C221, Type .V (Standard)
b. Facings for Insulated Interior Sheet: Flat, \STM C220,
Type F (Flexible)
c. Insulating Core: ASTM C200., Class E
B. Manufacturers; Same as for uninsulated.
C. Construction:
a. Exterior Sheet; Corrugated, same as uninsulated.
b. Insulated Interior Sheet: Sandwich type, 1-9/16" overall
thickness, with 1/8" flat asbestos-cement sheets factory
l-aminated to both sides of 1-5/16" thick insulating core,,
of one of following types and makes:
(1) Transitop.................. ............... Johns-Manville
.(2) Thermobord............. .................. National Gypsum
(3) Asbestone Panels.................. Philip Carey
D. Laps:
a. Exterior Corrugated Sheets: Same as uninsulated
b. Insulated Interior Sheets: Butt-joints
'
.
'
TABLE 5-2 REQUIREMENTS FOR SIDING AND ROOF ACCESSORIES
Item 1. Scope
f Requirements
1
A. `Accessories for giding and roofs shall include the following:
a. Outside comer rolls, inside corner rolls.
b. Flashing
c. Closures
,
d. Caulking and sealing.
e. Fasteners
B. Requirements for these accessaries shall be as specified in
this Table, except that requirements for fastener: are specified
in Table 5-3.
2. Corner Rolls A. Material: Asbestos-cement,- ASTM C221
. B. Corner Rolls: 6 to 8 inch les, 90, 2 to 3 inch radius comer, with overlapping bell ends. 4 to 12 feet long. Weight approximately 2% to 3% lb. per lineal foot.
3. Flashing
A. Material: 26 gauge (0.019") thick, Type 316 stainless steel.
*
I#
B. Location: Where indicated on drawings,
i
i
I BB 001226TM
5-3 Table 5-2 continued next page
s TABLE 5-2 ROOF ACCESSORIES, Cont.
K-2342 R
Item
4. Closures
5. Caulking and
Sealing
Reauirements
C. Installation: a. Lap one full corrugation where parallel to corrugations. b. Lap 4" minimum at right angles to corrugations and seal with closures as hereinafter specified.
A. Premolded closed cell neoprene, as approved, to match corrugations applied with "Dow Series 400" adhesive.
B. Location: Top and bottom, or ends, of sheets.
A. Material: a. Rope putty for side and end laps. b. Gray asbestos putty all other caulking. c. All caulking as approved.
B. Location: Provide continuous caulking and sea Ling for all horizontal, vertical and other joints in all siding, in all roofs, and in all applicable accessories as required to insure permanently sealed joints.
C. Indicate location and type of ALL caulking on zhop drawings.
TABLE 5-3 REQUIREMENTS FOR SIDING AND ROOF FASTENERS
Item
Req lirements
1. Attachment to Structural Members
A. V' lead head bolt. If bolt is electroplated, ;>olt shall be dipped in paint approved b/ Pittsburgh Plate Glass Company, prior to erection. If bolt is hot dip galvanised and lead head applied after galvanizing, no paint dip will be required. Provide 1/8" thick steel clips, hot dip galvanized as follows:
a. J-clips: Attachment to channels.
b. Z-clips or hook clips: Attachment to angle;.
B. Use of welded type fasteners not permitted.
2. Premolded Closures
Bolts: Use same bolts specified in Item 1.
3. Stainless Steel Flashing
Self-tapping screws, Type B, No. 12, minimum size and as follows:
A. Material; Type 316 stainless steel.
B. Heads and Washers: Recessed hexagon head, witl separate combined stainless steel washer and neoprene washer. Neoprene washer white or gray color.
4. General
Incorrectly installed fasteners, as determined by the Consulting Engineers, shall be removed aud replaced where anc as required.
5-4 1 BB 0012262 |
SARGENT & LUNDY
ENGINEERS
CHICAGO
K-2342
TABLE 3-4 SPACING OF SIDING. AND ROOF FASTENERS
Item. 1. Corrugated sheets to structural,
supports. '2. Insulated flat sheets to structural
supports.
3. Premolded Closures
Fastener spacing E^ery third corrugation, maximum.
A, .Not less than 4 fasteners per sheet to hold in place prior to installing.
B, 18" o.c. maximum.for fasteners passing through borh flat,sheet and corrugated sheet.
E/ery 2nd corrugation, or approxi mately 8V o.c.
5-04. SAMPLES REQUIRED Submit samples for following materials specified in this Section 5:
A. Uninsulated Corrugated Sheets: Standard sample.
B. Insulated Sheets: Standard sample.
C. Fasteners: Samples of ALL fasteners", iacluding both expose! and concealed fasteners, complete with c.lips, washers, etc. Clearly labeO each fastener as to type and use.
D. Closures: Standard sample.
*
E. Caulking and Sealing Materials: Samples of ALL caulking an! sealing materials. Clearly label each as to tyoe and use.
5-5 Final Page of Section 5
I
!
I BB 0012263 J
rxmiamvsnBir.lL.ic:.-l.
am, ,,
u*.. J&H&
PITTSBURGH PLATE GLASS COMPANY
CHEMICAL DIVISION
BILL OF MATERIAL
" W. " 6uan` itY QUANTITY
NO. WANT ED RECEIVED
DESCRIPTION
CHARGE
1l
L \ t\ 44 T* i ^4 ^ dT*l n u i
1,,* /A,
P-*>99 6 5t
UNIT
PRICING EXTENDED
E It
21
Lf<S4JTt
^AatMcT
Lib
1
Ll&UTlH^ C^ASjIkJ-ET
LC
41
r'~ t
Ca-> id-ct
LD
L^,^rr.iC,
('-tNtRfi.) LAu
'
& ZSOO rT
1 5"oco ~T $ 5odo '' O) 3000 'r
1 C 5^ -T* n i5a>0 "T
COPP!?M?e PoLYCTVW LH \U SO LfivTt oH P-T99
AWtf, -STPADDED- 5LAC-K
l
-OPPCnj V/I'-SS PouYCTLYL-EM . IM-SULATtOU
sfc \0.n AW(S, -STRANDED -
CoPfEft W ee FouYT+W;V ML. IVje>U _ A-riOM
'/o S0.i*2 , 7/<a S-TR-CvN
- Wv+IT.
Ooppcs? W|V;<= AouYETWVLCKvL (Wt.UL.ATiOM
l/6Nio,IOAW^ '6t AWDCD - &i-Act:
<0opp!3. Wi-st. Pot-TeTpY Lei-ie; iM-aULAi-i ow
1 !c Ko,iO'`.wA 6ti?^ndo - RD
COPPCFL Wl -?. H'olYT+WL-nJ / Nf *b<JL ATI OxJ
wc Mo. io Awe,
White
................ !
I'L Boc FT
1* 500 "T
dopPEff YA'^e, Imprc;hatd A*=e?e.-=>To-s-
TiPt ", '/L Me. 14 4^6, 5TRAW0CD - TOlAC*^
LoT'PLi? VlU'C. |MP"t<S,|4ATe D A-& Be *&f*3 i=>
TYPE
/<: fjo. |4AW`tf) *5t?ahoco- White
P-1W
i
*
i
14- 5oo Tr
if Aw 7ooc^t 1 & 24-0 :t
l/l" HOT !0 ',F'D - CHALVAHItlCC SP. iGnlD AbTCCL O c3M D J 1 T
i/4` roT L l PPCD ^ALVAMiZED *:TAlC ^>T L <0.0MCsOIT
Z" Hot `OtPPeo <, A L'/AWI SE O
3 z?TCL CONDUT
-
P-T99 4=2>l
1
PROJECT? L: n B.M. NO.: 6>J- ~ J 'ton Ksheet_Lof_^______________
HV. T.e^.
CHKti.i
iv|
APPt.:_________
0012264 J
MATERIAL FOR-... F 1 ^L-_V',.2-T-------U,KJ!" " -S)
LA< C HA gu < *~L
PITTSBURGH PLATE GLASS COMPANY
CHEMICAL DIVISION
BILL OF MATERIAL
MIL HUUTTfY' quantity NO. WANT :d RECEIVED
DESCRIPTION
. 16 H.r SH E.E ">
A
12. 5HEE'a
IP5IP 4,Z"Cor-^RUGtATErt) ASBESTOS CEMENT SIDIMQx IO'-3*' L.OSJC*
3 . ^"COPRUGATEO ASISE'STOS .CEM&WT SlOISJG* * B'-O" LOWGt
z ^ .. 4,rCOPlRUCv<>.TEn xai-jE-iTOtj 13. SHEETS -r/toE72s" CEMENT S.HDIS4G, m 3'-3" t_OkJ<=N
PfizcjzS-z.
|4. Piece a
51 ... 42*COR^UOl4.TEfc /k&FBE.-STO'o .CEMENT 'BlOlLJC-i &/CSTTEJ\J
&>"STTPUP5*^ X
LOMC,
CHARGE
PRICING
UNIT
EXTENDED
IO io
15, shee ~s
A,z"cop.RUCiAcreD HSs.fa.ersTo^b ' CZE.MEKJT . SinOlWCS, FOR ROOF h
\6>. n,
pieces
-2. PIECE.S.
7*-<i" U'NOi
*
50*/Sv'S.RiE.srro ==': c-Eime-M/T . PursiirE ccoPi.s4e.PE. Roll with
&OVEPL^.vPPINC, E5RE.U- ElMCD^
~ '-<=3'* LONCq
:.Wz. ..
POUUD /NPiESTOti C.E.rv|E.NT
Ple2> RTirDC^ ROU. v fi'-O* L-OVJ O
-
16/ \./-7.
2.-:.'
A^ae^ros cement r3.iocs,E. roll (aA.TTE.Sj*6 x <C/' LOWOi
19.
7.
.. 2,::
P*.ITDG|. FROUL. E.VjrD CLOSURE. .FC4vSMING,S TYPE, 3(6/
S>T/^ISll_(.*SS4 *BTee.L. z<-<=iAOCr,e i6xPPR.O>N- MBCSJ., FT, EACH
S 20,: Pieces
PieS&'.ss:
70" AWbESTOS CLC.KAETNJT JNJ5ltD ODIR.Sje.PL ROL.L FDR.
^tt/SVE CVNFftL_B TRIM * &>'-QH
ICONIC*
SO.-Z,~bo _ p>Ec&:.2f PI EC 116
/1" 'VIrati 1 WSI DE CLOSURE. ^Srr=Mr= H.57.&' L.ONj<=*. PREMOLO-
0 "CLOSED CLL ,
^'
weopr ewe.
... &
. S___ _lt.'`WirOE OUTSIDE CLOSURE
2z: Pi EC 2S PfCS - STRIPS x 37.8" LOSJC*. PREMOLDED
.
.ct~oso CEX.L. MEopnesje
l
!i ii:;
il if
i
-23."' 'lO
- yer:.r. TZ"Wlot rRirDCaE. FROL.L. CLLOEbURS.
PIECES Pieces " SXPtlP >. B7. &" UDSJCn/PRCMOUDErD
ASPHALT COMPOSITION
-- -
24 . &
36=
25
& . : TRU'D CD,EL TOCxCxLES lVCb`'x {g>
thick z,alV/ksjizeo
pfc
l4"43
HEZSTD PbOLTS k 1 'x"
. U.&UC* WITH CiALVANlZE.R
4 SVASH CL7JS* ^ nju-ts,
t.
2<2r
27.
AS
-6" UM4 LEAJC3. HEAD J^aOUr-^ x 6" ' L.C3LJC.V VITH MUTS,;
-
:
`
iC<dp Ue/".rD' HE-ArD" .fSOUT,S.
Cosjcd with N4UT*=>
-X
3*"
.
BB 0012265 |
|
PROJEC Tt
B.M.NO. ; ,,,>/
SHCETJ
9 :
'
BY:. f^AM.
r.uKv C^AJjTyKI'ARoNlEra-
appv
. -v
MATERU . cao.OEMISJ&P^AUZCK
-M..Pt-AH JT \#7T
r^"
I
J'lcvL. _. ."D',.ViUf
1