Document NG5ypEarmJdoMEoZ2NgxDVvgb

General Offices - St. Louis 66/ Mo, August 30, i960 USB OF PYDRAULS IN COAL MINUS Your memo to A.T. Hinson - 8/24/60 A. ?. Hinson - St. Louis R. S. Kelly, M.D.-St.Loulf H. R. Newman - MCL Newport D, ?. Smith - St, Louis Mr. J. F. Churchill MCL - London Original correspondence filed Pydraul F-9 In Dr. Kelly's absence, I would like to forward one cocvr.ents of the Medical Department concerning the use of Pydrauis In underground air pumping machinery, I am not familiar with how much formulation or composition data MCC is allowed to divulge in the case of the Pydrauia, I believe it ia caramon knowledge, however, that most of these are phosphate ester baaed fluids with "chlorinated hydro carbons", Within the past year, the labels on containers of Pydraul sold in the United States bear the statement: "Contains Chlorinated Hydrocarbons". It became neceseary to add this to our labels because of legal labeling, requirements in several of the states. The Medical Department cannot recommend the use of the Pydrauis which contain "chlorinated hydrocarbons" in.any application where workmen must insnerae their arms and hands in the fluid for any prolonged period, or even for a short period, if they oannot soon thereafter wash thoroughly with soap and water. The interpretation of "short and long periods" is relative. Perhaps an example of what wa have in mind would be pertinent. Garage mechanics working on automobile engines customarily have a film or layer of lubricating oil or grease on their hands and anna from the time they start work in the morning until they finish their shift (perhaps a growing number wash their hands before eating lunch). Except for occasional cases of oil acne or dermatitis, there is no particular harm in this practloe. . A similar exposure to our Pydrauis containing "chlorinated hydrocarbons" could not be tolerated. Skin irritation, chloracr<e and possible systemic Injury due to absorption through the ^unbroken skin would occur, ; DSW 586092 STLCOPCB4091426 Mr. J. F. Churchill--Page 2--August 30> I960 By contrast, I think that if a mechanic or nalntenar.ee .nan iuad the Fydraul on his hands and arms for r.z more than ten or fifteen minutes once or twice a day, and washed thoroughly aft *r each such exposure, no systemic Injury or ehloiacne would develop. At the same ti.no, the men might still develop some dermatitis due to the advent action of the fluid on the oils and fata normally present on the surface of the skin. It may' be possible to promote the use of a Fydraul which does not certain chlorinated hydrocarbons (cock aa Pydraul 60) without any important skin or toxicity problem. Even with tnese, however, continuous exposure could jcad to tne defatting or solvent action mentioned above. EPW:dh Elmer P. Wheeler Blind note to Dr, Newman Dear Harold: I think when you were over here we discussed the pydrauls to some extent. In any case, most of these fluids contain one or more of the Aroclors in varying percentages. Pydraul A-200 is approximately 98$ Arocior formulation of two of the Aroclors. A3 indicated in the letter above, I am not sure hew free liCC is with formulation data since these fluids are part of a development and sales program with Douglas Aircraft. If you can find out which Pydrauls are Involved In this application, I can send you confidential composition data. I am glad your return trip wa3 pleasant and uneventful. Sincerely, EPW DSW 586093 STLCOPCB4091427