Document NG3O143nKGoaqr5nRE31GQV0E

Air Conditioning Automatic Heating System Gar Wood Industries, Inc. (SjKzfWootQ AIR CONDITIONING DIVISION 7924 Riopelle St., Detroit, Mich. Licensed Distributors in All Principal Cities TEMPERED-AIRE UNITS Made in six (6) capacities, with filters, blower, burner, humidifier, oil furnace and economizer engineered into one compact, coordinated sys tem. Clean, humidified, filtered, warmed air is delivered from the unit to the duct system and then uniformly distributed to all parts of the building. Air is cleaned by washable cloth filters and circulated by a multiple-blade ball bearing blower, rubber mounted. The heating unit is a counterflow, down-draft furnace and Cross-Sectional View of Tempered-Aire Unit economizer unit, equipped with an integral fire bowl and pressure atomizing oil burner. The humidifier is a flash type, steam tube, located within the firebox, assuring prompt humidification. The 1941 line of Tempered-Aire units covers a wide range (Models 001, 101, 201, 301, 401, 501), and has many improve ments. The perfected Model "O" oil burner starts, operates and cuts off smoothly even with widely varying draft conditions. Combustion is clean, quiet and efficient, due to the improved manner in which the air and oil are mixed and burned in the horizontal, cylindrical fire bowl to produce the efficient, sunburstshaped flame. Improved Functional Design Tempered-Aire Ratings &nd Dimensions No. 001 No. 101 No. 201 No. 301 No. 401 No. 501 Btu 1 Hour at Bonnet.................... Btu 1 Hour at Grilles..................... *Air Delivery CFM.......................... Oil Nozzle Size G.P.H.................... Heating Surface. Sq. It.................. ! liter Area. Sq. ht.......................... Motor HP--Burner........................ Motor HP--Blower........................ Overall Length. Inches................... Overall Width. Inches.................... Overall Height. Inches............. Dim.--Supply Opening.................. Dim.--Return Opening.................. Blower Wheel, Dim........................ Shipping Weight, lbs....................... TStack Connection, dia.................... Recommended Chimney Size......... 85.000 68.000 850 .85 40 30 X X 71 48 28y,'il4V,' 28>/2'xl4%" 10**10* 760 7* 8**12'*30' 100.000 80.000 1.000 1.00 54'/2 30 X 32 54 35**163// 28>/2'xl&3/4' 12**12* 900 7* 8**12**30' 135.000 110.000 1.350 135 64 48 y<, a 83 32 54 36'/2'xl6y.' 32'/2'xIS3/4' I4*xl4* 1.000 8* 8**12**30' 200.000 160.000 ZOOO 2.00 86 52 X 1 3*y 57 36V4'*l6y4' 36**163// 16*x!6* 1.200 9* 12**12**35' 300,000 240.000 3.000 3.00 124 78 K Vi 116 45 65 50**21'// 47'/2'x2I'/,,' 20**20* 1,500 2-10* 12**16**40' 400.000 320.000 4.000 4.00 164 ^ 78 Vc 1 131 45 65 65**21'// 47'/i'x2I,/4' 20**20* 1.800 2-10* 12**16**40' Ratings based on 160 deg bonnet temperature and 68 deg return temperature. Greater air deliveries with correspondingly lower bonnet temperatures may be had by the use of larger blower motors. fOn Models 401 and 501 connect both stack outlets to chimney. GAS-FIRED AIR CONDITIONING UNITS Seven units: 60V, 84H&V, 120H&V, 168H, 240H, 360H, 480H (V, vertical type; H, horizontal). The model numbers designate the heat inputs in thousands of BTU's per hour. Three standard ized basic heating sections (5-, 7-, and 10-fluted) used singly and in multiple produce the seven sizes and heating capaci J^5-jluUd heating section ties. The horizontal types--approximately 4% feet in for MODEL 60V height--are ideal for basements with unusually low MODEL 60V (Vertical Type) ceilings. The vertical types (while also designed for basements) occupy small space and are suitable for smallest in 1941 line of seven gas-fired units installation in heater-utility rooms--located on the first floor--where space is definitely limited. 834 Gar Wood Industries, Inc. Air Conditioning Automatic Heating Systems BOILER-BURNER UNITS For steam and hot water heating systems. Eight sizes: Series "B" 5 sizes; Series "R" 3 sizes. Cross-sectional view of Models 135, 180 and 870 Models 1S5, ICO and 870 Models 180 and 165 Series "B" B-I20-W B-I35-S or W B-I65-W B-180-S or W B-270-S or W Boiler Nozzle Output B.T.U./Hr.......................... Net Load Rating B.T.U./Hr...................... *......... Boiler Nozzle Output Sq. Ft. 240 B.T.U./Hr. Steam Radiation................................ ........ Boiler Nozzle Output. Sq. Ft. 150 B.T.U./Hr. Hot Water Radiation......................................... Net Load Capacity 240 B.T.U./Hr. Steam Radiation.............................................. - Net Load Capacity 200 B.T.U./Hr. Hot Water Radiation............................................................ Net Load Capacity 150 B.T.U./Hr. Hot Water Heating Surface. Sq. Ft......................................... Size Steam Nozzle................................................... Recommended Chimney Size................................ Water Capacity. Gallons--rSteam.......................... Water..........................Internal Tankless Water Heater (Dual Coil)......... Internal l ank Type Water Heater (Single Coil)... Shipping Weight--Pounds..................................... 120.000 80.000 -- 800 -- 400 533 30 1.20 *0'' 1-3* 1-3* 7* 8**12**30' -- 14 -- -- 885 135.000 90.000 562 900 375 450 600 34 135 "O" 1-3* 1-3' 8* 8**12**30' 40 51 -- 30* 1000 165.000 110.000 -- 1100 550 733 44 1.65 "O" 1-3* 1-3* 8* 8**12**35' -- 20 -- -- 1100 180.000 120.000 270.000 180.000 750 1125 1200 1300 500 750 600 900 800 46 1.80 -0" 1-3* 1-3* 8* 12**12**35' 46 64 200* 30* 1300 1200 64 2.70 `*0" 1-4' 1-4* 9' 12**16**40' 64 88 200* 30* 1585 Gallons per Hour 80 Temperature Rise at 180 Boiler Temperature. Series "R" RIOOO R1400 R1800 Burner Model.............................................. D Oil Jet Size--Gal. per Hr............................ 3.50 Max. Net Steam Load, Sq. Ft.................... 1000 Max. Net Hot Water Load, Sq. Ft............ 1600 Max. Cross Steam Load. Sq. rt........... 1500 Max. Cross Hot Water Load, Sq* Ft......... 2400 Heating Surface. Sq. Ft.............................. 84 Size Steam Nozzle....................................... 4* Size Return Connections............................. 2-2W A--Overall Height. Jacket........................ 687, B --Overall Width, jacket.......................... 37% C --Overall Length. Jacket........................ wy4 U--Height Steam Nonle........................... m. E--Height Return Connections................. 29V. h --Height External Heater Connection... 43% C --Height Mean Water Line.................... 47V, H--Height Smoke Pipe Adapter............... 40 1 --Hor. Distance Between Returns......... 7 J --Hor. Distance Between Steam Nozzles Stack Size.................................................... 12* Recommended Chimney Size.................... 12**16**40' Water Capacity, Cals.................................. 52 Shipping Weight. Lbs.................................. 2200 D 5.00 1400 2240 2100 3360 118 2-4' 2-2'/2' 68V, 37% 66 683/, 293/, 43% 49% 40 7 18 12* 12**16**45' 69 2500 D 6.50 1800 2880 2700 4320 154 2-4* 2-3' 683/, 37% 80 683/, 29'/, 43>/, 49% 40 7 18 12" 16**16**45' 91 2950 SERIES "R" The series "R" BoilerBurner Units are de signed for larger instal lations where their sepa rate boiler shells and fire boxes facilitate rigging and erection. CONVERSION OIL BURNER Model "OC" For installation in existing heating plants. DOMESTIC WATER HEATERS Model S50--coil type heater for separate storage tank. Cap. 50 gal. per hour 100 F rise. Model S40 has storagetank integral. Cap. 40 gal. per hour 100 F rise. Vertical rotary burner. Model S50 Model SiO 835