Document NEvynMoyNdGZ1RLd8kVKY1y7R

Air Conditioning, Automatic Heating Systems The Henry Furnace & Foundry Company Manufacturers of MONCRIEF Furnaces & Air Conditioning Systems 3471 East 49th Street Cleveland, Ohio Phone Michigan 9322 Moncrief Aristocrat and "Special" Oil Fired Winter Air Conditioners, made to operate with any standard Gun Type Burner, and Gas Fired Winter Air Con ditioners are available in numerous sizes and capacities. Write for particulars. Henry Furnace & Foundry Air Conditioning, Automatic Heating Systems Moncrief Aristocrat Coal-Fired Winter Air Conditioners are made with either cast or steel heating elements, in a wide range of sizes. Equipment includes metal floor, blower with motor, filters, controls, dam per motor, thermostat and Thermo-Dnp Automatic Humidifier, duplex roller-bear- ing grates--except with triangular grates, at no extra cost (on cast only). If to be used with stoker, grates and controls-- except blower control--may be omitted, stokers being equipped with control. Finegrain crackle finish--green, trimmed with chromium plate. Oil Fired Air Conditioner "SPECIAL" OIL FIRED AIR CONDITIONERS Unit No. Size of cuing: Width............................................ Height........................................... 75 .76 28' 71' 60)/a' no 1/6 6120 915 2 75.000 100 1.02 28' 71' 6oye' 112 % 6120 1225 2 100.000 Btu Per hour at Reg. Cfm Blower Motor Hp I i Sq In. ! Heating , Surface No. of Filters i Size of Filters if?8 (Approx.) Input Gal Per Hour SIZES, CAPACITIES--Aristocrat Oil-Fired Units. A. C. Unit | Size No. Cuing Dimensions Plenums Warm Cold Air Air cA B D E b G |H T K L M N in 1 CQ 125 76% 51% 60V, 481/, 28 sty. 58%l5J6 18 20 28 20 28 125,000 1525 M2 % 8925 4 16x25 1240 1.28 150 76% 51$ 6% 48y2 28 51% 18 24 28 24 28 175 80% 56$ m. 52% 28 51% 43% 5% 18 24 M 24 32 150,000 1830 114 175,000 2200 114 % H 8925 11088 4 4 16x25 1265 1.53 16x25 1365 1.8 200 80% 56% 6oy,, 52% 28 51% 43,/,13y, 18 24 36 24 36 200,000 2440 114 % 11088 4 16x25 1455 2.04 275 97 64% 64 59 58 51% 51% 5% 18 30 40 30 40 275,000 3350 214 % 13248 6 16x25 2010 2.8 SIZES, CAPACITIES--Gas-Fired C.B.F. Units. Btu Input Btu at Register Blower Size Motor Hp No. of Filters Filter Size Cfm Required Sq In. Heating j Surface' \ Gas Line | No. of Burners Unit No. Casing Dimensions Plenum Size Inches Warm Cold Air Air A B cD EK L M N N in 3 U. G-8 75 20 54 </i 13 14 32 16 14 80,000 61.200 110 1/6 2 16x25 748 G-12 75 26 G-16 75 34 54 54 W, 13 12 19 .26 32 34 22 30 15 12 120,000 160,000 91,800 122.400 112 112 % A 3 16x25 1124 4 16x25 . 1500 G-20 75 41 54 !'/z 12 32 34 37 12 200,000 153,000 114 X 4 16x25 1870 G-24 75 49 54 i% 12 40 34 44 12 240,000 183.600 1(4 % 5 16x25 2244 G-32 G-40 75 75 68 54 78% 54 1m% 12 12 52 66 34 34 60 72 12 320,000 244.800 12 400,000 306.000 714 214 % % 6 8 16x25 16x25 2994 3740 G-48 75 94% 54 i % 12 80 34 88 12 480,000 367,200 214 9 16x25 4480 5410 2 6' 8115 3 6' 10820 4 7' 13525 5 8' 16230 6 8' 21640 w 27050 i'/*" 8 10 9' itr 32460 i%* 12 ii' 910 With Cast Heating Element. Unit Casing Lumensions-- Size inches No. A B c D Eh Plenum Size Warm Cold air air K LMN Blower Size Motor Hp Sq In. Heating Surface Grate Area Sq In. Cfm Re No. of quired Filter# Forced Air Register Btu Coal Hand- Fired Forced Air Register Btu Stoker Fired 4020 66% 40% 62% 38% 28 50% 30 28 30 18 110 4422 68% 42% 67% 38% 30 50% 32 28 32 20 112 % % 5021 214 967 5609 269 M57 2 73.800 85,200 3 88,300 101.800 4824 70% 44% 62% 40% 30 50% 34 30 34 20 M2 5226 78% 46% 66 44% 34 50% 36 34 36 22 M2 % M 6010 326 1330 6753 397 1580 3 101,600 117.300 4 120,400 139,000 5628 82l/4 48% 66 48% 34 50% 38 38 38 24 114 7579 472 1840 5 140,300 162,000 With Steel Heating Element. Blower Size || | Motor Hp Sq In. Heating Surface Grate Area Sq In. Cfm Required | No. of Filters | Forced Air Register Btu Coal HandFired Forced Air Register Btu 1 Stoker Fired | Unit Size No. Casing Dimensions---inches ABcD FG Plenum Size Warm Cold air air K LMN 2054 68% 40% 62% 40% 28 50% 35% 30 30 30 16 HO 2254 70% 44% 62% 40% 30 50% 59% 30 34 34 18 112 2456 74% 46% 66 40% 34 50% 41% 30 36 36 20 M2 2758 74% 51% 67% 40V, 34 50% 46V, 30 42 42 20 114 3060 86'/, 54% 69 48% 38 50% 49% 36 42 42 24 212 3060J 90% 54% 69 52% 38 50% 49% 40 42 42 24 212 3462 90% 60% 71 48% 42 505/, 55% 36 48 48 24 214 3462J *% 60% 71 54% 42 50% 55% 42 48 48 24 214 % % V. a X % 5/. '/, 6226 6499 6960 8086 10041 11480 11245 12386 214 269 330 434 552 552 730 730 1070 1232 1424 1815 2240 2362 2800 2895 2 81,600 94,200 3 94,000 108,400 4 108,700 125,500 5 138,600 160,000 5 171,000 197,300 5 180,300 208,000 6 213,600 246,700 6 221,200 255,200 Heating capacities are based on a 7 lb combustion rate using 12,000 Btu coal and efficiencies of --65 per cent at bonnet, 85 per cent register for fan coal hand fired--75 per cent at bonnet, 85 per cent at register for oil or stoker fired. If 6 lb combustion rate is desired for prolonged firing period deduct approximately 15 per cent from forced air Btu ratings. Maximum velocity through filters, 200 feet per minute. The Anthracite Winter Air Conditioner consists of a MONCRIEF Unit and a Miles Combustion Modulator. The outside temperature is correlated with the warm air temperature to affect a Graduated Room Temperature, 68 deg in mild weather and 78 deg in zero weather. Constant Modulated Heat Supply eliminates COLD 70 and complicated control equipment. Write for particulars. Note: Made with either the Moncrief Cast or Steel Aristocrat Air Conditioner. 911