Document NEvynMoyNdGZ1RLd8kVKY1y7R
Air Conditioning, Automatic Heating Systems
The Henry Furnace & Foundry Company
Manufacturers of MONCRIEF Furnaces & Air Conditioning Systems
3471 East 49th Street
Cleveland, Ohio
Phone Michigan 9322
Moncrief Aristocrat and "Special" Oil Fired Winter Air Conditioners, made to
operate with any standard Gun Type Burner, and Gas Fired Winter Air Con ditioners are available in numerous sizes and capacities. Write for particulars.
Henry Furnace & Foundry Air Conditioning, Automatic Heating Systems
Moncrief Aristocrat Coal-Fired Winter Air Conditioners are made with either cast or steel heating elements, in a wide range of sizes. Equipment includes metal floor, blower with motor, filters, controls, dam per motor, thermostat and Thermo-Dnp Automatic Humidifier, duplex roller-bear-
ing grates--except with triangular grates, at no extra cost (on cast only). If to be used with stoker, grates and controls-- except blower control--may be omitted, stokers being equipped with control. Finegrain crackle finish--green, trimmed with chromium plate.
Oil Fired Air Conditioner "SPECIAL" OIL FIRED AIR CONDITIONERS
Unit No.
Size of cuing: Width............................................ Height...........................................
75
.76
28' 71' 60)/a' no 1/6 6120 915 2 75.000
100
1.02
28' 71' 6oye' 112 % 6120 1225 2 100.000
Btu Per hour at Reg. Cfm Blower Motor Hp I i Sq In. ! Heating , Surface No. of Filters i Size of Filters
if?8
(Approx.) Input Gal Per Hour
SIZES, CAPACITIES--Aristocrat Oil-Fired Units.
A. C. Unit |
Size No.
Cuing Dimensions
Plenums
Warm Cold Air Air
cA B
D E b G |H T K L M N
in
1
CQ
125 76% 51% 60V, 481/, 28 sty. 58%l5J6 18 20 28 20 28 125,000 1525 M2 % 8925 4 16x25 1240 1.28
150 76% 51$ 6% 48y2 28 51%
18 24 28 24 28
175 80% 56$ m. 52% 28 51% 43% 5% 18 24 M 24 32
150,000 1830 114 175,000 2200 114
% H
8925 11088
4 4
16x25 1265 1.53 16x25 1365 1.8
200 80% 56% 6oy,, 52% 28 51% 43,/,13y, 18 24 36 24 36 200,000 2440 114 % 11088 4 16x25 1455 2.04
275 97 64% 64 59 58 51% 51% 5% 18 30 40 30 40 275,000 3350 214 % 13248 6 16x25 2010 2.8
SIZES, CAPACITIES--Gas-Fired C.B.F. Units.
Btu Input Btu at Register Blower Size Motor Hp No. of Filters Filter Size Cfm Required Sq In. Heating j Surface' \
Gas Line |
No. of Burners
Unit No.
Casing Dimensions
Plenum Size Inches
Warm Cold Air Air
A B cD EK L M N
N in 3 U.
G-8 75 20 54 </i 13 14 32 16 14 80,000 61.200 110 1/6 2 16x25 748
G-12 75 26 G-16 75 34
54 54
W,
13 12
19 .26
32 34
22 30
15 12
120,000 160,000
91,800 122.400
112 112
% A
3 16x25 1124 4 16x25 . 1500
G-20 75 41 54 !'/z 12 32 34 37 12 200,000 153,000 114 X 4 16x25 1870
G-24 75 49 54 i% 12 40 34 44 12 240,000 183.600 1(4 % 5 16x25 2244
G-32 G-40
75 75
68 54 78% 54
1m%
12 12
52 66
34 34
60 72
12 320,000 244.800 12 400,000 306.000
714 214
% %
6 8
16x25 16x25
2994 3740
G-48 75 94% 54 i % 12 80 34 88 12 480,000 367,200 214
9 16x25 4480
5410
2 6'
8115
3 6'
10820
4 7'
13525
5 8'
16230
6 8'
21640 w 27050 i'/*"
8 10
9' itr
32460 i%* 12 ii'
910
With Cast Heating Element.
Unit Casing Lumensions-- Size inches No.
A B c D Eh
Plenum Size
Warm Cold air air
K LMN
Blower Size
Motor Hp
Sq In. Heating
Surface
Grate Area
Sq In.
Cfm Re No. of quired Filter#
Forced Air
Register
Btu
Coal Hand-
Fired
Forced Air
Register
Btu Stoker Fired
4020 66% 40% 62% 38% 28 50% 30 28 30 18 110 4422 68% 42% 67% 38% 30 50% 32 28 32 20 112
% %
5021 214
967
5609 269 M57
2 73.800 85,200 3 88,300 101.800
4824 70% 44% 62% 40% 30 50% 34 30 34 20 M2 5226 78% 46% 66 44% 34 50% 36 34 36 22 M2
% M
6010 326 1330 6753 397 1580
3 101,600 117.300 4 120,400 139,000
5628 82l/4 48% 66 48% 34 50% 38 38 38 24 114
7579 472 1840
5 140,300 162,000
With Steel Heating Element.
Blower Size || | Motor Hp Sq In. Heating Surface Grate Area Sq In. Cfm
Required | No. of Filters |
Forced Air Register Btu Coal HandFired Forced Air Register Btu 1 Stoker Fired |
Unit Size No.
Casing Dimensions---inches
ABcD
FG
Plenum Size
Warm Cold air air
K LMN
2054 68% 40% 62% 40% 28 50% 35% 30 30 30 16 HO 2254 70% 44% 62% 40% 30 50% 59% 30 34 34 18 112 2456 74% 46% 66 40% 34 50% 41% 30 36 36 20 M2 2758 74% 51% 67% 40V, 34 50% 46V, 30 42 42 20 114 3060 86'/, 54% 69 48% 38 50% 49% 36 42 42 24 212 3060J 90% 54% 69 52% 38 50% 49% 40 42 42 24 212 3462 90% 60% 71 48% 42 505/, 55% 36 48 48 24 214 3462J *% 60% 71 54% 42 50% 55% 42 48 48 24 214
% % V.
a
X % 5/.
'/,
6226 6499 6960 8086
10041 11480
11245 12386
214 269
330 434
552 552
730 730
1070 1232 1424 1815 2240 2362
2800 2895
2 81,600 94,200 3 94,000 108,400 4 108,700 125,500 5 138,600 160,000 5 171,000 197,300 5 180,300 208,000 6 213,600 246,700
6 221,200 255,200
Heating capacities are based on a 7 lb combustion rate using 12,000 Btu coal and efficiencies of --65 per cent at bonnet, 85 per cent register for fan coal hand fired--75 per cent at bonnet, 85 per cent at register for oil or stoker fired.
If 6 lb combustion rate is desired for prolonged firing period deduct approximately 15 per cent from forced air Btu ratings. Maximum velocity through filters, 200 feet per minute.
The Anthracite Winter Air Conditioner consists of a MONCRIEF Unit and a Miles Combustion Modulator.
The outside temperature is correlated with the warm air temperature to affect a Graduated Room Temperature, 68 deg in mild weather and 78 deg in zero weather.
Constant Modulated Heat Supply eliminates COLD 70 and complicated control equipment. Write for particulars. Note: Made with either the Moncrief Cast or Steel Aristocrat Air Conditioner.
911