Document NEq1jGQNpN6DLxzLNVjReZVQE

MI'OWIID Y D. R. Cova K. W. Holbert PROGRESS REPORT ORGANIC CHEMICALS pIVlSION TECHNOLOGY DEPARTMENT .o 10/1/73 1/30/74 DETAIL* Yes REPORT NO. DATE 2 2/15/74 LOCATION Research Center - St. Louis JO & NO* 1005105 pleas* m iohn Thii doeurmnl ! tht proparty of MONSANTO COMPANY. It contain* CONFIDENTIAL INFORMATION which mutt not ba raproduead. ravaalad 10 unauthorlxad parioni or tant outfit* tha Company without proper authorization. The recipient it mpomlbU for Itt tafakaaping and dettrueilon. . DISTRIBUTION `WITH DETAILS W. R.Richard A. Leisy *J. P. Quinn *R. H. Munch C. W. Roos *K. E. Boucher oitojt t r mte J. R. Savage R. M. Kountz *D. K. Lynch<"-' *V. Brawley L. B. Skatoff *G. Johnson MONOCHLOROBIPHENYL IM'ftJlCI OO.IKCTIVC Development of a process for monochlorobiphenyl. SUMMARY The reflux ratio program for monochlorobiphenyl (MCBBP) fractionation was optimized. Distillate composition curves were developed for comparison with plant-scale fractionation. Material balances were developed for MCBP fractionation for product containing either high or low levels of p-chlorobiphenyl. Dow's preference at this point is for low-para MCBP. This makes for easier fractionation control but increases the size of the residue fraction to be disposed of. Residue from MCBP fractionation was converted to Aroclors 1016, 1242, and 1254. Electrical properties were all satisfactory. Infrared analy sis and chromatographic analysis showed differences from the standard products due to changes in isomer concentrations. Aroclor 1016 and 1242 (from MCBP residue) formed crystals on holding at low temperatures. Aroclor 1254 from residue also formed crystals at low temperatures, but when mixed with trichlorobenzene (for transformer use) it appears to be equivalent to standard Aroclor 1254 from the W. G. Krummrich Plant with respect to crystal formation at low temperatures. D. R. Cova FUTURE WORK 1. Continue work on residue disposal. HONS 058270 2i Write Process for Interim Quantities. 3. Obtain additional toxicity and enviromental information on MCBP. -CONFIDENTIAL- Progress Report No. 2 Monochlorobiphenyl Page 2. DETAILS I. Fractionation to Make MCBP A. General Procedure This fractionation is carried out in semi-continuous fashion in a 30-tray column under vacuum. The 30-tray col umn was chosen to simulate the Aroclor 1016 column at the W. G. Krummrich Plant. Column head pressure was set to give stillpot pressure equivalent to that expected in the plant. Likewise the ratio of column holdup to stillpot charge (about 0.05) was maintained close to that experienced in the plant. After a period at total reflux, distillate flow is started at a relatively low reflux ratio. At the same time Aroclor 1110 is fed into the stillpot at the same rate as distillate is taken off. At some point the Aroclor feed is cut off, and the intermediate cut from the previous run is fed in. At some point during this time, reflux ratio is increased to keep the o-chlorobiphenyl (o-CBP) concen tration low in the distillate. When all of the intermed iate fraction has been fed in, the reflux ratio is increased to 15/1. From here on, fractionation is in the batch mode. An increase in head temperature signals the end of the forefraction and the beginning of the intermediate fraction. The intermediate fraction is collected separately and is held for recycle to the next fractionation batch. The fore cut can be recycled back to the chlorination reactor. Level ing off of'the head temperature indicates depletion of bi phenyl from the head of the column. This signals that the end of the intermediate fraction is near at Rand. When the biphenyl concentration has fallen sufficiently, the dis tillate flow is diverted to the main fraction receiver and the reflux ratio is lowered (generally to 8/1). Main fraction is taken off until the level of m-chlorobiphenyl (m-CBP) in the main fraction approaches 4.0t. At this point, distillation is stopped. In our laboratory experi ments additional small fractions are taken around each cut point. After all these fractions have been analyzed they are mixed in the proper order and amount to make up the _ four fractions called for, forecut, intermediate cut, main fraction, and residue. B. Feed/Charge Ratio and Reflux Ratio Program The purpose of the semi-continuous mode of operation is to reduce time spent in charging the stillpot, batch -CONFIDENTIAL LOWS 058271 Progress Report No. 2 MonochloTobiphenyl Page 3. heatup, establishing the concentration gradients at total reflux, and dumping residue. For this reason, it is de sirable to maximize the feed/charge ratio. As the fraction ation proceeds in the semi-continuous mode, biphenyl is selectively removed from the system. Column feed must be stopped before the biphenyl is depleted. Otherwise, o-CBP will reach the head of the column and be taken over in the forecut. The optimum feed/charge weight ratio was found to be 0.63 (the feed here consists of both Aroclor 1110 and the intermediate cut from the previous batch). The reflux ratio program was optimized, and the final program decided upon is as follows. After a total reflux period to establish the column gradients, distillate flow is started to the forecut receiver at a reflux ratio of 3/1. At the same time Aroclor 1110 is fed to the stillpot at the same rate as distillate is taken off. After 91.4 lbs. of distillate has been collected, the reflux ratio is increased to 5/1. After 102.1 lbs. of Aroclor 1110 has been fed, its flow is stopped, and the intermediate cut from the previous run is fed (on the virgin batch where there is no intermediate fraction to be fed, an additional 40.3 lbs. of Aroclor 1110 is fed to the stillpot). When 40.3 lbs. of intermediate fraction has been fed, the feed is stopped and the reflux ratio is increased to 15/1. After a total of 155.3 lbs. of forecut has been collected, the distillate flow is diverted to the intermediate cut receiver. After 40.3 lbs. of intermediate fraction has been collected, the distillate flow is diverted to the product receiver and the reflux ratio is lowered to 8/1. 100 lbs. of MCBP is distilled off at this reflux ratio. At the end of this period the fractionation is stopped, and 71.4 lbs. of residue is pumped from the stillpot to the residue receiver. The forecut contains 4.91 o-CBP. Increasing the reflux ratios during this cut to 5/1 and 8/1 (instead of 3/1 and 5/1) would reduce this concentration to about 2-1/21. Since the forecut is returned to the chlorination step where it is converted to Aroclor 1110, most of the o-CBP is recovered (except for that converted to dichlorobiphenyl). It is estimated that operation at the lower reflux ratios will mean a loss in yield of only 0.4t. The reflux ratio of 15/1 at the end of the forecut and through the intermediate is essential to reduce the size of the intermediate fraction and to maximize the size of the product fraction. -CONFIDENTIAI.- MQNS 058272 Progress Report No. 2 Monochlorobiphenyl Page 4. A reflux ratio of 8/1 is recommended for the main fraction. It was found that a lower reflux ratio (5/1), while it gave an adequate product (though higher in p-CBP), gave an increased residue. The increase was about 8 lbs. per 100 lbs. of MCBP. C. Instantaneous Distillate Concentrations In two of our fractionations, sets of small (1-2 cc) samples were taken. These represented instantaneous dis tillate samples which should be very useful in comparisons with fractionations in the plant column. In plant scale fractionations, instantaneous samples are easily had whereas composite samples are more difficult to obtain and are necessarily of a historical nature. Figure 1 in the appendix depicts the fall of biphenyl concentration in the distillate through the intermediate fraction and into the main fraction. The concentrations are plotted against percent of the charge plus total feed distilled. On the semi-logarithmic plot the curve is a straight line with a break at low concentrations. This break may represent analytical error, a small degree of decomposition in the stillpot to form biphenyl, or biphenyl holdup in an area infrequently washed by distillate. Figure 2 depicts the changes in concentration through the main fraction and beyond it if the fractionation is continued further. Concentration curves for m-CBP, p-CBP, and 2,2'-dichlorobiphenyl (2,2'-DCP) are depicted. Figure 3 shows o-CBP concentration in distillate through most of the forecut during the time that the stillpot is being fed. D. Material Balances for Plant Runs Material balances proposed for plant runs are given in Tables I and II. The balance in Table I deals with the first fractionation run when there is no intermediate cut to be fed to the stillpot. As would be expected, raw material requirements and the forecut and residue are high er than normal. On any succeeding runs where intermediate fraction is available to feed the stillpot, the Aroclor 1110 requirements and the forecut and residue sizes will be nor mal as in Table II. -CONFIDENTIAL- HONS 058273 Progress Report No. 2 Monochlorobiphenyl Page S. 11, Product Analyses, Specifications and Environmental Consider ations A. Product Compositions and Tentative Specifications In the past three months, more fractionations of Aroclor 1110 were carried out for the purpose of generating residue for residue disposal studies and also to make samples of high-para MCBP. The original MCS 1547 product specifica tions gave a product containing 111 or less p-chlorobiphenyl (p-CBP). Three months ago Dow requested MCBP containing at least 141 p-CBP. In order to meet this specification it was necessary to distill further into the residue. This necessitated loosening specifications to the following: Typical Specifications Product Biphenyl o-Chlorobiphenyl m-Chlorobiphenyl p-Chlorobiphenyl Total Polychlorobiphenyl 0.61 max. 75.04 min. 5.51 max. 14.04 min. 1.34 max. 0.471 78.34 4.644 15.64 0.854 In the second column of the above table is a typical analysis of laboratory product. Table III in the appendix presents a material balance for the high-para process. More recently, Dow have had another chance of heart and have decided that they prefer the low-para MCBP. Low-para MCBP, which is identical with MCS-1547, has the following specifications: Typical Specifications Product Biphenyl o-Chlorobiphenyl m-Chlorobiphenyl p-Chlorobiphenyl Total Polychlorobiphenyl 0,64 max. 80.04 min. 4.04 max. Remainder 1.04 max. 0.504 85.751 3.084 10.254 0.414 The second column of the above table gives an analysis of typical laboratory product. Table II in the appendix presents a material balance for the low-para product. Comparing material balances for the low- and high-para products shows that the low-para product generates more residue per 100 lbs. of product (15.5 lbs. more residue per -CONFIDENTIAL- MONS 058274 Progress Report No. 2 Monochlorobiphenyl Page 6. 100 lbs of MCBP). Therefore, the low-para process increases the problem of residue disposal. B. Analyses of MCBP for Trace Components Table IV in the appendix gives analyses (by J. P. Mieure) for trace components in the first lab sample of MCS-1S47, of low-para MCBP, and of high-para MCBP. It is evident that the preponderance of polychlorobiphenyls in these three MCBP samples consists of 2,2'-dichlorobiphenyl which ranged in concentration from 0.1S to 0.854 in the samples. All the remaining trace components shown in Table IV add up to no more than 500 ppm (or 0.051). C. Environmental Considerations An acute toxicity screen was carried out on MCS-1547 (a sample of MCBP). The results showed no unusual acute toxicological properties of the material (see memo, Johannsen, F. R. to D. R. Cova, 11/5/73, in the appendix). Studies have been started on tissue accumulation in rats, acute fish toxicity, rat inhalation, and a 90-day feeding study for sub-acute toxicity. Ill. Residue Disposal Aroclor 1016 was made from the residue of low-para MCBP. The MCBP residue was straight takeover distilled to remove lime. This distillate was chlorinated to Aroclor 1142 and then fractionated semi-continuously in a 30-tray column to give Aroclor 1016. Analysis of this product at the V. G. Krummrich Analytical Laboratory gave 0.304 High-Boiling Homologs (HBH). The specification on HBH is 0.404. In frared analysis showed that the same compounds were present as in standard Aroclor 1016, but the various concentrations were different. On cooling the sample down, a white solid formed between -5 and -10eC. This solid (which is 4,4'dichlorobiphenyl) did not redissolve on warming up to room temperature. Aroclor 1016 was also made from the residue of high-para MCBP. The procedure was the same as above. This product was placed in a freezer whose temperature cycled between -14 and -20*C. After two weeks the white solid had formed. In standard Aroclor 1016 from the W. G. Krummrich Plant no solid formed. The conclusions from infrared analysis of the product were the same as with the previous sample. -CONFIDENTIAL- MGNS 058275 Progress Report No. 2 Monochlorobiphenyl Page 7. HBH analysis gave 0,381 Electrical properties were good (0.00066 dissipation factor, 4.80 DK, and 344 x 106 resis tivity). Table V in the appendix compares chromatographic analysis of this product to standard Aroclor 1016. This material contains twice the concentration of 4,4'-dichlorobiphenyl as does standard Aroclor 1016. In general, those compounds containing para-chlorine are increased in con centration, while those having no para chlorine are reduced in concentration. This is as expected since MCBP residue contains over 501 p-CBP. In an attempt to resolve the problem of solids formation at low temperatures, Aroclor 1016 from MCBP was diluted down to 301 and 401 concentrations with standard Aroclor 1016. After two weeks in the freezer both mixtures gave solids formation. After two more weeks the 404 mix ture still had solids, but none were detected in the 30t mixture. Aroclor 1242 was made from high-para MCBP residue by straight takeover distilling the residue from the Aroclor 1016 fractionation above and mixing it with the 1016 in aliquot portions. Part of this Aroclor 1242 mixture was placed in the freezer where, afteT 3 weeks, crystals were detected in it. The remainder of the mixture was converted to Aroclor 1154 by further chlorination, then to Aroclor 1254 by straight takeover distillation. This Aroclor 1254 sample was placed in the freezer. After nine days crystals were found in the material. This material was then diluted 50/50 with standard Aroclor 1254 from the W. G. Krummrich Plant and placed in the freezer along with the standard Aroclor 1254. After two weeks neither sample had formed crystals. The above Aroclor 1254 sample (undiluted with standard 1254) and standard Aroclor 1254 were each diluted to 704 and 604 concentration with trichlorobenzene (TCB). These four samples were placed in a freezer held at -40"C. The purpose of this test was to duplicate transformer conditions in a cold climate. After six days both samples that con tained 404 TCB showed crystals. The other samples con taining only 304 TCB contained no crystals although the mixture made with standard Aroclor 1254 was cloudy. Ap parently, TCB is the material solidfying. The undiluted Aroclor 1254 sample tested out satisfactorily for electrical properties (0.00054 dissipation factor and 4.36 decay). Infrared analysis of the sample showed it to -CONFIDENTIAL- MOMS 0582 76 Progress Report No. 2 Monochlorobipheny1 Page 8. be similar to standard Aroclor 1254 with small concentra tion differences. At this point Aroclor 1254 from MCBP residue appears to be equivalent to standard Aroclor 1254 for transformer use. As expected, chromatographic analysis shows changes in isomer concentration from standard Aroclor 1254. IV. Miscellaneous Experiments Aroclor 1016 from MCBP residue was isomerized over A1C1] to see if the isomerized product would be more similar to standard AtocIot 1016. It was not. The isomerization appeared to consist of concentrating most of the chlorine on one ring. In one experiment the MCBP fractionation was carried further to remove the p-CBP from the residue as a tail cut. This tail cut was chlorinated to 301 chlorine, then mixed with the MCBP residue in aliquot portionsand frac tionated to make MCS-1043. The product was not suitable, because it contained too much 4,4'-dichlorobiphenyl. The p-CBP concentration of MCBP was varied in an attempt to reduce the crystallizing point sufficiently low to make a suitable solvent for tolylxylylsulfone. The low est crystallizing point found was 9*C, and this concept was dropped. HONS 058277 APPENDIX HONS 058278 I. V ~T f, I /. /V ffv I i I r/tJ 3. . Co Urofd JJf. \..... fi- to fX 60 of Chapih + Ffft> if 70 Biphenyl Ortho 2,2'-Dichlor Meta Para Dichlors Trichlors Tetras TABLE I LOW-PARA MCBP. FIRST FRACTIONATION RUN Charge* Crude Feed* Fore Interned. Main 1------------------- Fraction Fraction Fraction Residue ` 45.08 27.02 1.52 3.77 17.66 4.22 .28 .37 45.08 27.02 1.52 3.77 17.66 4.22 .28 .37 94.45 5.48 .00 .01 .03 .00 32.25 67.62 .00 .04 .08 .00 .48 85.56 .45 3.87 9.52 .00 .06 2.26 5.59 . 11.65 61.35 16.4S 1.11 1.46 ; ' 7S7BS0 SNOW TOTAL 287.22 215.41 221.52 52.09 100.0 .. Charge and feed analysis was calculated from the compositions and weights of distillate cuts and residue. 129.02 1 iif ! | t Biphenyl Ortho 2,2'-Dichlor Meta Para Dichlors Trichlors Tetras TABLE II MATERIAL BALANCE FOR LOK-PARA MCBP Charge* 45.37 28.16 1.49 3.01 15.45 5.52 .30 . -28 Crude Feed* 45.37 28.16 1.49 3.01 15.45 5.52 .30 .28 Intermed. Fore Intermed. Main Feed Fraction Fraction Fraction 1 Residue 31.82 67.75 .03 .08 95.13 4.87 31.82 67.75 .03 .08 .44 83.78 .60 . 3.65 11.24 .02 .05 .90 6.00 8.67 54.94 25.25 1.39 1.28 EB78S0 SNOW TOTAL 224.6 102.1 40.3 155.3 40.3 100.0 ` : : i _______________________________________ * The analysis of the charge and crude feed was calculated from the analyses and weights of all the other streams entering and leaving the system. j 71.4 1 I Biphenyl Ortho 2,2'-Dichlor Meta Para Dichlors Trichlors Tetras TABLE III MATERIAL BALANCE FOR HIGH-PARA MCBP Charge* 46.3 28.3 1.3 3.0 14.9 S.O 0.4 0.2 Crude Feed* 46.3 28.3 1.3 3.0 14.9 S.O 0.4 0.2 Intermed. Fore Intermed. Main Feed Fraction Fraction Fraction 33.1 66.4 0.1 97.5 2.5 33.1 66.4 1 0.1 0.41 79.3 0.89 4.50 14.6 0.04 Residue 0.10 0.6 5.6 8.1 53.1 26.8 1.9 1.2 HOMS 0 5 8 2 8 4 TOTAL 202.1 92.9 44.6 139.1 44.6 100.0 55.9 * The analysis of the charge and crude feed (same as thecharge) was calculated from the analyses and weights of all the other streams entering and leaving the system. l TABLE IV TRACE COMPONENT ANALYSIS IN MCBP SAMPLES Peak No. Peak Identity First Lab Sample of MCS 1547 MIC 207152 Blend 2 MIC 207162 Low-Para MCBP 1-10 11 12 13 14 13 16 17-19 20 21 22 23 24 2S 26 27 28 29-34 7 Biphenyl 7 7 o-Chlorobiphenyl 7 7 m S pchlorobiphenyl and 2,2-dichlorobiphenyl a dichlor 7 a dichlor a dichlor 7 7 7 4,4' -dichlor 7 7 20-30 ppin total - 20 ppm 50 ppm 30 ppm 50 ppm ^10 ppm total - 40 ppm 100 ppm 30 ppm 70 ppm 65 ppm 90 ppm <5 ppm <5 ppm 22 ppm 30 ppm 35 ppm 30 ppm 6 ppm 3 ppm 3 ppm <3 ppm 4 ppm <3 ppm 80 ppm <10 ppm 4 ppm 'vSO ppm total iprobably less than 50 ppm MIC 207175 High-Para MCBP <10 ppm total - 50 ppm 40 ppm 30 ppm 80 ppm 190 ppm <3 ppm 40 ppm 40 ppm <3 ppm <3 ppm < 5 ppm <5 ppm ) Very low Note: Peaks 1 through 28 were determined with a 4 meter x 1/8" dia. Santicizer 409 column at 200C and a helium flow of 40 ml/min. Peaks 29 through 34 were detected using an OV-17 column 4 meters x 1/8" dia. at 260'C. Flowrate was 20 ml/min. The dtector was a flame ionization unit in both cases. MONS 058285 Monsanto Medical, A2SC November 5, 1973 MCS 1547 - Acute Toxicity Screen Y-73-182 TO D. F. Cova T3C The attached toxicity report characterizes the results of the acute screening studies with MCS 1347. The following data summarize those results: Skin Irr. Eye Irr. Vapor Inhalation (max=8.0) (max-110,0) (mg/L) mortality 2,370 >2,000 2.4 7.6 0.0 0/6 This material appears to possess no unusual acute toxicological properties.that would require special handling practices other than the good hygienlce practices employed with any Industrial chemical. Akp att. HONS 058286 ` Younger Laboratories INCORPORATED 183 CLIFF CAVE HOAD BAfNT LOUIS, MO., 60129 MONK* (J14) 4IT4M1 Toxicologic lnvetig*tlon of; HCS 1547 Lot Number 001-NBP207155 0ll, 10/2/73 Toi Monsanto Company St. Louis, Missouri (3166 Project No. Y-73-182 ACUTE ORAL TGXfCITY Specfes Spraguc-Davley Albino Hats LDbo 2,370 Mg/Kg 95* Confidence Limit, 2250 - 2490 CONDITIONS Fod Undllutsd - Slngls Oral Doss Mg/Kg t 2000 7 2510 3 3160 4 3900 5 6 ------Avr ' ` Initial Weigh-t---------- 1 Malt Female 220 215 220 225 240 225 210 220 Mortgllttas/Oosed Mala Ftmala Combined 0/2 1/3 1/5 1/3 2/2 3/5 2/2 1/3 3/5 2/3 2/2 4/5 Tima of Mortality Ons to thrss days Roduced sppetlts and activity (ons to thres days In survivors). Sign, of Intoxication Increasing voakness, collapse, and death. Grott Autopsy Decedents Lung and liver hyperemia and acuto gastrointestinal Inflammation. Survivor, ( 7 Day,) Viscera appearod normal ACUTE OERMAL TOXICITY Specie, Nov Zealand Albino Rabbits LO50 CONDITIONS ^ 2,000 Mg/Kg 95% Confidence Limit, Appllod Undiluted - 24 hours exposure """ Mg/Kg Dotaft* Mg/Kg 1 1260 2 2000 3 3160 4 5010 6 6 Sign, of Intoxication Initial Weight Mala Famata 2.5 -- -- 2.4 2.6 -- -- 2.3 Mala 0/1 -- 1/1 -- Mortailtles/Dosed Ftmala Combined -- 0/1 0/1 0/1 -- 1/1 1/1 l/l *Tima of Mortality 1 Day 2 Days Reduced appetite and activity (ono to two days In eurvlvors), Increasing woakness, collapse, and death. Grot, Autopty Decent, llcnorrhaglo areas of the lungs and liver, slightly enlarged gall bladder, and gastrointestinal Inflatmatlon. . Survivor, ( l* Day,) Viscera appeared normal. HONS 0582(7 Vis Niitulil In thlt report li to be used In development ol the product end may be (Ivin to responsible sales contacts, but It lg not to be weed by them In advertising ropy The seurre ol thli material It not to ba divulged until It irdm'i In formal publications No earaptlona to tha eatebllahed rula may be martt wlll'OUt tha approval of it,a Matheal Department In St Louis. Customars' Inquiries regarding matters et toxicity ora to be relerteq ee betete to the Mtmt.mu, Cdrttii.tny Mdtt Ml Dep.iMinimt In M l.ou.s lor imply. TEST MATERIAL LOT NUMBER PROJECT NO. MCS 1547 001-HDP207X55 T-73-XB2 fir 7 ACUTE EYE IRRITATION Irritation Score 174. aa, 77 trout avc.i 7*6 Species New Zealand Albino Rabbits Claisilication Slight * Dour and Condition! o.l Ml. applied undiluted /F.H.S.A./ 24-lIoura Expoaura P.H.8.A.I NOT claaaad at an aye Irritant 1 ime of Mr.wf<np Mown ICfl STRUCTURE CORNEA IRIS CONJUNCT IV AE CORNEA mis CONJUNCTIVAE CORNEA IRIS CONJUNCTIVAE CORNEA IRIS CONJUNCTIVAE 0 0 2 0 0 10 SCORES ANIMAL NUMBER 34 I Man Scor* 4X/1 tOI banedlatai Discomfort win 7.6 light 1-llr. t Slight to moderatj erythema,very alight 4)am 2.3 coplout dlaeharga |24-Hr. t Slight to moderat erythema, vory alight l.-dcr alight to modarata dlrnhai 1.2 5-HrI Slight to moderate! erythema ~r2.Hr.i Slight arythema 0.0 PRIMARY SKIN IRRITATION Speciei Kcw Zealand Albino Rabbits Itriialion Score or. r> Hour A.a i 2.4 Classification Moderate * Dow and Condition! 0.5 Ml. applied undllutod /F.1I.S.A./ 24-Uours Exposure * F.H.S.A.i HOT elaaaed aa a primary akin- Irritant ' EHY1 HLMtA ` Anim.tl NiMiiltr' 7 3 4 l> C i 1 iSllttJ 4 iA 00 00 11 11 00 00 34 1A li ll il lX li li 416 1A ll li ll Xl il lX 72 1A lX l1 00 lX 00 1l 168 1A 00 00 00 00 00 00 4 ,A 00 00 00 00 00 00 24 ,A 22 33 22 22 22 22 `46 1A l2 22 22 22 12 22 72 1A Xl 1l 1l Xl 1l 1 .l 166 1A 00 00 00 00 00 00 Comments Blight defatting affact - flaked off In seven to ten days. Ho Injury In depth. INHALATION TOXICITY " AMBIENT TEMPE1MTURE Species Spragut-Devley Albino .Maia Rata Lri|iosiite period 4 Hours Mortality 0/6 Vapor concert. 0.0 Crum / M Avq. chamber lump . 26 C. Avg chamber rel. humidity ' 85 ' % Chamlrer capacity 25 L. Air llow rate 4.0 L./min. hritial sample tire 112.0 Grama Recovered sample size 112.0 Grama Srimfite vaporised 0.0 Grata . Recovered from condenser 0.0, Gram li'trns ot Intoxication Hons Tan day observation period uneventful linns Autopsy Decedents imvivoist 40 Days) Viscera appeared normal MONS 056266 T,,.i Mi'UtuU H.-lciencc A.T. S. 8/73 Submituul lv^ MELVIN Da. DliLCU. MONS 058289 Page Number 207165 207167-8 207169-70 207171 207172 207173 207174 207175 207176 207177 207178 207179 207181 207182 TABLE VI DESCRIPTION OF EXPERIMENTS _________ _______ Description Fractionation of Aroclor 1142 from chlorinated MCBP residue to make Aroclor 1016. Fractionation of Aroclor 1110, fourth in a re cycle series. Fifth fractionation of Aroclor 1110 in the re cycle series. Blending of cuts from 207165 to make Aroclor 1016 made from the residue from low-para MCBP. Composition of standards and area correction factors for MCBP fractionation. Sixth fractionation of Aroclor 1110 in the re cycle series. Distillation of MCBP residue by STO distilla tion. Making up of high-para MCBP from cuts from 207167. Blending of tail cuts from 207173, 207169, and 207167 for chlorination. Chlorination of mixture from above to 324 chlorine level. Analyses by J. P. Mieure of various MCBP sam ples for trace components. Fractionation in a 30-tray column of a mixture of the chlorinated material from 207177 and distilled residue from 207174 in aliquot por tions to make MCS-1043. The 4,4'-chlorobiphenyl content was too high. Chlorination of an aliquot mixture of blend from 207176 and distilled residue from 207174 (representing the residue from high-para MCBP distillation! to make Aroclor 1142. Fractionation of material from 207181 in a 30tray column to make Aroclor 1016. -CONFIDENTIAL- MONS 050290 Table VI - Description of Experiments (Cont'd.) Page Number ;Description 207183 Blending of cuts from 207182 to make Aroclor 1016. This product formed a small amount of solids on standing a couple of weeks in a freezer. 207184 Isomerization of Aroclor 1016 from MCBP residue (207183) over AICI3 catalyst. 207185 Addition of more p-chlorobiphenyl to high-para MCBP to see if crystallization temperature would be appreciably lowered. It was not. 207186 STO distillation of isomerized Aroclor from 207184. This product looked even more dissimilar from Aroclor 1016 than did that from MCBP residue. 207187 STO distillation of residue from Aroclor 1016 fractionation on 207182. 207188 Dilution of Aroclor 1016 from high-para MCBP residue down to 404 and 304 with standard Aroclor 1016 before storing in the freezer. After 3 weeks a few crystals formed. 207189 Blending of distillate from 207187 with cuts from Aroclor 1016 distillation on 207182 to make Aroclor 1242. This material was placed in the freezer and precipitated out some crystals after 3 weeks. 207190, 207193 Seventh fractionation in the recycle series. In this run a lower reflux ratio was used in the forecut and instantaneous samples were taken throughout the distillation for the first time. 207191 Chlorination of Aroclor 1242 from 207189 to Aroclor 1154 to simulate production of Aroclor 1254 from MCBP residue. 207192 STO distillation of Aroclor 1154 'from 207191 to make Aroclor 1254. This material was placed in the freezer and crystals formed after 1-1/2 weeks. 207194 STO distillation of residue from Aroclor 1016 fractionation on 207165. 20719S Analyses of instantaneous samples from 207190, 207193. -CONFIDENTIAL- MONS 058291 Table VI - Description of Experiments (Cont'd.) Page Number Description 207196 207197 K 207198 207199 Aroclor 1016 and 1254 samples placed in freezer. Eighth fractionation in the recycle series. A low reflux ratio was again used in the fore fraction and the feed/charge ratio was reduced slightly. Analyses of samples from 207197. Freeier tests of Aroclor 1254 diluted with tri chlorobenzene. -CONF1DENTIAL- MONS 058292