Document NEkQVg4x1KmK2Xxveqp6qkKDQ
(1) Review of Process Basic raw materials used for the production of asbestss-
canent (A/C) pipe include asbestos fiber, portland cement, silica sand, and water. After fiber introduction to the process (see Section O.l.b.), convey-
ir.g equipment carries "the raw fiber to a dry mixing step. Agitation in this
step serves two purposes: opening or fluffing the fiber, and mixing the
cement constituents. Sand and portland cement are added at this point,
typically being conveyed pneumatically to an enclosed, live-bottom mixer.
The dry mix next passes by a conveyor to a wet-mixing operation just
upstream of the pipe-forming machine. The wet mortar flows to the pipe
forming machine vats, where the asbestos cement slurry is picked up on a
rotating, screened cylinder mold and transferred on a traveling belt over
suction boxes, where, as a wet mat, it is wrapped on a mandrel. Wrapping
continues to .attain proper thickness. Pipe sections generally are cast in 10-
to 15-foot lengths. After an initial setting time, the pipe is stripped frcm
the mandrel, then air cured, and final cured in an autoclave using saturated
steam.
Cured pipe sections are transported to the finishing operations. Here
the pipe is cut to uniform lengths and machined in a variety of ways (sawing,
lathing, drilling) ar.d outfitted with a coupling. To insure a tightly fitted
pipe joint, the ends of the pipe sections are machined smooth on a lathe. The
finished pipe is inspected, and each section of "pressure pipe" (pipe used for
conveying water under pressure) is tested hydrostatically.
In addition to full and partial lengths, pipe plants also produce a
variety of standard and special fittings. Pipe coupling is the most widely
used fitting. To mate with the machined pipe, inside surfaces of the coupling
must be grooved to hold a rubber seal. Other fittings (tees, elbows, reducers,
i etc.) are produced on a less frequent schedule. Host pipe plants also produce
t I
specialty fittings and pieces on an individual basis. Operations required far
fittings production include sawing, drilling, machining, boring, and bonding.
Some specialty applications require pipe lengths to be machined over their
entire length with a lathe-.
(2) Current Controls and Work Practices
Fiber loss to the work environment at the dry-mixing stage
is controlled by maintaining negative-pressure inside*the mixer--itself an
appendage to a local-exhaust dust-control system. The mixer generally receives
and dispenses raw- material' by a screw conveyor. Local exhaust is also employed
at the wet-mixing operation. Introduction of the dry mortar into the mixer
and initial agitation until the solids become wet produce the dust at this
0 02j67
step. ' Cnee the mortar becomes wet, little additional fiber becomes airborne.
A significant portion of the fiber emitted between fiber introduction and wet
mixing may result from material handling equipment (such as screw conveyors
and bucket elevators). Oust control in conveying equipment is obtained by
using continuous exhaust of hoods and maintaining, negative pressure within the
closed mixing equipment.
".
No special control equipment is used during pipe formation, air curing,
and steam curing. Nevertheless, good housekeeping is essential at these steps
because spills of mortar or fragments of pipe will dry and ultimately result
in fiber release due to pedestrian and vehicular traffic.
Aside from fiber introduction, pipe-finishing machining operations repre
sent the major potential source of airborne fibers iri an A/C pipe plant.
Extensive local exhaust and hooding must be used near the tool cutting surface
to capture and control fibrous solids, including chips. Using single-point
cutting tools (instead of saws or cutting and machining equipment that'use
abrasion) substantially reduces fiber emissions at the finishing step.
Control equipment for coupling and fittings production is essentially the
seme as that described for pipe finishing. Local exhaust near the working
point of the tool is used to capture and remove soLids. Variability in produc
tion techniques and in pipe- sire makes designing tight-fitting hoods difficult.
As a dust control measure in the finishing end of the production of
asbestos-cement pipe, Johns-Manville's Oenison, Texas,"plant has adapted its
existing- exhaust ventilation system to provide local vacuuming at all of its
pipe finishing, operations. A typical arrangement is illustrated in Figure III-3.
A SCO- to SCO-cubic feet per minute blower provides the suction for the pickup
of dust and debris. Large debris falls out in a chip trap which is then
transportad by an airlock feeder to an exhaust duct. Fine dust that does not
gravitate cut in the chip trap is pulled through the blower and then exhausted
into the exhaust ductwork. This system- offers a less expensive alternative to
the- installation of a central vacuum system.
(3) Reported Exposure Levels
Reported exposure levels are presented in Chapter II.
(4) Future Controls Under development
Wet mixing immediately after fiber introduction is being
used in at least one cement pipe plant. This process modification precludes
III-29
0 002168
in
v3> {>u
ctu/J >O
CowacJ. o a 2 3
C/3
cmrrnAp
Plcjiire f I I - 3 . Typical Arrangement fo r Vacuum Cleaining System Using Local Exhaust V e n tila tio n System
any mixing and thus eliminates one potential source of fiber loss to the work environment. Advancing, control technology for reducing exposure to asbestos in the finishing operations includes redesigning machinery with integrated local exhaust. Standard milling equipment and machinery with minor modifica tions have been used in pipe finishing. Significant reduction in worker exposure could be achieved if the machinery were redesigned to improve dust capture.
Wet machining has been used in some areas of the A/C pipe finishing and fitting production, and development work is underway to determine if:
Wet suppression can be adapted to the pipe lathes; and if * Wet.-finishing reduces the fiber release at this processing st3ge. Considerable automation.could also eventually be incorporated into machinery redesign, thereby reducing employee exposure.
D 002170