Document NEdg5MMNnYr85MbQ3p4mYMN7E
American Society of Heating and Ventilating Engineers Guide, 1928
Table 6-D. Coefficients of Transmission (U) of Various Types of Masonry Wall Construction
Note.--These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. difference in temperature between the air on the two sides and are based on an outside wind exposure of 15 miles per hour.
Hollow/'Tile Walls with* Stucco Ex.Ttc.Voe. FuJisu
The values .of. -U in this Table are based on the
/&fl,owi'nq Internal Conductivities (C) which are
expressed m 6.t.u .per Ur. per Sq. ft, per t*F .
Stucco,
-8.00- per l*
Uollow-Tile -6.050 8-045 . U-O 26 l*-ai85
Cement .Mortar
8.00 per f
Plaster Board*
3.4 perl'
Plaster-(Gypsum)
2-52 per l*
WbodLath 4 Plaster
2.00 as applied
Cork- board
0.30 per T
Fiber Insulation (Board form) 0.33 per l*
Cellular Gypsum (18*) .
Q. 59 per f
Powdered Gypsum
0.52 perl"
YThickness q/lnsulation where specified
_uVo51
Interior Construction'
Y
34 Plain Walls -- klo Interior-.finish
Thickness- of Hollow Tile -X
fc* 8*
a b
12* 16* c d-
CL3Z0 0.Z3I
0.201 0.153
35. Plaster on Uollow Tile
o.zqq 0-2-73. O.I33- 0.143
36' ^-Plasteron Metal Lath'-- Furred
0.203 0.130
0.147
aizo
37 Plaster on Wood Lath - Furred
ai3i 0.184
0.(44
0117
3A ^ Plaster on Ve* Plaster board -- Furred
4 Plaster on Wood Lath on Z" Furrmq 33 Strips -- Cellular Gypsum fill
Plaster on'Wood Lath on-2.* furrmq .40' Strips - Powdered Gypsum Fill
*
1%'
* 1%`
0.202 0.157 0.148
0.130 0.143 0.142.
41` -jr Plaster on fiber Insulation --
"VL- /Board /orm) Furred
43 Plaster on Cork board set in Vz
Cement Mortar 44,
Vz 0.158 . 0-150
r 0.127 0.122
Hi 0.113
aii5
t O.OIT ' 0.036
a 147
0.120
0.IZZ
O.IOZ
0.116
0.033
0.IZ2
0.103
6.103
0.083
0.038 "ao&5
0.084
0.074
Based on 1% in., the actual thickness of 2 in. furring strips. fFigures on this page can be used with sufficient accuracy for hollow tile walls without stucco finish/
24 Y'
Chapter I--Calculating the Heat Losses from Buildings
Table 6-E. Coefficients of Transmission (U) of Various Types of Masonry Wall Construction
tfolg'--'These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. difference in temperature between the air on the two sides and are based on an outside wind exposure of 15 miles per hour.
LiuestoOe ob Saudstoue Walls
The values of U in this table are based on .the
/ollowinq Inbernal Conductivibies (C) whichare
expressed in 6.t.u. per Ur. per Sq.ft, per.lr
Stone
10-00 per i`
Cement Uortar
8.00 per E
Plaster Board
-L0-1 per f
Plaster (Gypsum-)
LJ2 per f
Wood. Lath 4 Plaster
1.00 as applied
Cork board
0.10
Fiber Insulation (Board form) 0.35
Cellular Cypsum (I8*X
0.53
Powdered Gypsum (26*)
0.52
per r
per r
per f per f
Wall Humber
Y-Thickness of Insulation where speci/ied Interior Construction
45 Plain Walls -- Uo Interior Finish
Thickness of Stone - X
Y 8* 10* 12* 16* '20*' Z'4-' ..
abc
de
w
0.556 a 502 0.457 0333 0.334 0:Z35
46 Plaster on *3 tone
0i437 0.452 0-415 0.556 0l3I1 0.277
47 ^Plaster on Metal Lath - Furred.
0277 0.26Z 0.243 0.227 0.208 o.m
48 Plaster on Wood Lath - Furred.
0.264 0.251 0.2 jq 0218 0.200 a 185
4q Plaster on 3/fe Plaster Board - furred
50
Plaster on Wood Lath on 2" furrmq * Strips -Cellular Gypsum fill
51
Plaster on Wood Lath on 2* furrmq Strips - Powdered Gypsum Fill
.52' Plaster on Fiber Insulation -- 53 (board /orm) Furred
54'. i Plaster on Cork board set in x/i 55 Cement Mortar
o'275 0.261 0.248 0.226 0.207 0131 *
0.138 0.131 0.184 0.171 0.160 0.150 * 1% 0.185 0.178 0.172 0161 0151 0.143
k 0.133 0.132 0.184 0172 0.161 0.151'
0153 0143 0.144 0136 0.123 0,723
lie 0.141 0.138 0.134 0127 0.(21 aiis
i 0.114 0.112 0.103 0105 0.101 0038
Based on 1% in. , the actual thickness of 2 in. furring strips.
25