American Society of Heating and Ventilating Engineers Guide, 1928 Table 6-D. Coefficients of Transmission (U) of Various Types of Masonry Wall Construction Note.--These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. difference in temperature between the air on the two sides and are based on an outside wind exposure of 15 miles per hour. Hollow/'Tile Walls with* Stucco Ex.Ttc.Voe. FuJisu The values .of. -U in this Table are based on the /&fl,owi'nq Internal Conductivities (C) which are expressed m 6.t.u .per Ur. per Sq. ft, per t*F . Stucco, -8.00- per l* Uollow-Tile -6.050 8-045 . U-O 26 l*-ai85 Cement .Mortar 8.00 per f Plaster Board* 3.4 perl' Plaster-(Gypsum) 2-52 per l* WbodLath 4 Plaster 2.00 as applied Cork- board 0.30 per T Fiber Insulation (Board form) 0.33 per l* Cellular Gypsum (18*) . Q. 59 per f Powdered Gypsum 0.52 perl" YThickness q/lnsulation where specified _uVo51 Interior Construction' Y 34 Plain Walls -- klo Interior-.finish Thickness- of Hollow Tile -X fc* 8* a b 12* 16* c d- CL3Z0 0.Z3I 0.201 0.153 35. Plaster on Uollow Tile o.zqq 0-2-73. O.I33- 0.143 36' ^-Plasteron Metal Lath'-- Furred 0.203 0.130 0.147 aizo 37 Plaster on Wood Lath - Furred ai3i 0.184 0.(44 0117 3A ^ Plaster on Ve* Plaster board -- Furred 4 Plaster on Wood Lath on Z" Furrmq 33 Strips -- Cellular Gypsum fill Plaster on'Wood Lath on-2.* furrmq .40' Strips - Powdered Gypsum Fill * 1%' * 1%` 0.202 0.157 0.148 0.130 0.143 0.142. 41` -jr Plaster on fiber Insulation -- "VL- /Board /orm) Furred 43 Plaster on Cork board set in Vz Cement Mortar 44, Vz 0.158 . 0-150 r 0.127 0.122 Hi 0.113 aii5 t O.OIT ' 0.036 a 147 0.120 0.IZZ O.IOZ 0.116 0.033 0.IZ2 0.103 6.103 0.083 0.038 "ao&5 0.084 0.074 Based on 1% in., the actual thickness of 2 in. furring strips. fFigures on this page can be used with sufficient accuracy for hollow tile walls without stucco finish/ 24 Y' Chapter I--Calculating the Heat Losses from Buildings Table 6-E. Coefficients of Transmission (U) of Various Types of Masonry Wall Construction tfolg'--'These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. difference in temperature between the air on the two sides and are based on an outside wind exposure of 15 miles per hour. LiuestoOe ob Saudstoue Walls The values of U in this table are based on .the /ollowinq Inbernal Conductivibies (C) whichare expressed in 6.t.u. per Ur. per Sq.ft, per.lr Stone 10-00 per i` Cement Uortar 8.00 per E Plaster Board -L0-1 per f Plaster (Gypsum-) LJ2 per f Wood. Lath 4 Plaster 1.00 as applied Cork board 0.10 Fiber Insulation (Board form) 0.35 Cellular Cypsum (I8*X 0.53 Powdered Gypsum (26*) 0.52 per r per r per f per f Wall Humber Y-Thickness of Insulation where speci/ied Interior Construction 45 Plain Walls -- Uo Interior Finish Thickness of Stone - X Y 8* 10* 12* 16* '20*' Z'4-' .. abc de w 0.556 a 502 0.457 0333 0.334 0:Z35 46 Plaster on *3 tone 0i437 0.452 0-415 0.556 0l3I1 0.277 47 ^Plaster on Metal Lath - Furred. 0277 0.26Z 0.243 0.227 0.208 o.m 48 Plaster on Wood Lath - Furred. 0.264 0.251 0.2 jq 0218 0.200 a 185 4q Plaster on 3/fe Plaster Board - furred 50 Plaster on Wood Lath on 2" furrmq * Strips -Cellular Gypsum fill 51 Plaster on Wood Lath on 2* furrmq Strips - Powdered Gypsum Fill .52' Plaster on Fiber Insulation -- 53 (board /orm) Furred 54'. i Plaster on Cork board set in x/i 55 Cement Mortar o'275 0.261 0.248 0.226 0.207 0131 * 0.138 0.131 0.184 0.171 0.160 0.150 * 1% 0.185 0.178 0.172 0161 0151 0.143 k 0.133 0.132 0.184 0172 0.161 0.151' 0153 0143 0.144 0136 0.123 0,723 lie 0.141 0.138 0.134 0127 0.(21 aiis i 0.114 0.112 0.103 0105 0.101 0038 Based on 1% in. , the actual thickness of 2 in. furring strips. 25