Document NEZVMegMgd7b01wez5Lpz7RDQ

Johns-Manville Service to Railroads Asbestos Roofings, Packings and Insulations: Steam and Electrical Railroad Supplies PLAINTIFFS i EXHIBIT P 3^?2<,QQ. Akron Albany Atlanta Baltimore Birmingham Boston Buffalo Canton Chicago Cincinnati Cleveland Manville Incorporated Executive Offices: New York PLAINTIFFS EXHIBIT wu pi snq Columbus Dallas Dayton Denver Detroit Duluth Erie Grand Rapids Houston Indianapolis Kansas City Los Angeles Louisville Memphis Milwaukee Minneapolis Nashville Newark New Orleans Omaha Philadelphia Pittsburgh Portland (Me.) Providence (R. I.) Rochester St. Louis St. Paul Salt Lake City San Diego San Francisco Seattle Syracuse Tacoma Tulsa Washington Wilkes-Barre Worcester (Mass.) Youngstown Havana, Cuba Montreal Canadian Johns-Manville Co., Limited Ottawa Toronto Vancouver Printed in V. S. A. Winnipeg CRMC-003366 Johns-Manville Factories and Mines CRMC-003367 A Few of the Main Johns -Manville Branches CRMC-003368 Johns-Manville Service to Railroads Johns-Manville Service to Railroads A Contribution to America's Progress stablished in 1858, johns-Man- E, ville has achieved and maintained supremacy in its field because, through the scientific development of As does it fit the needs of this new world of steam, electricity and blazing furnaces, that it seems to have been almost pur posely designed. bestos, it has served the industrial world and its life-giving arteries of trade, the railroads, as has no other institution in America. More than half a century has been de voted by Johns-Manville to making As bestos fill these needs efficiently and econ omically; and this catalog is in reality a More than a century back, the power of record of accomplishment. We are pre steam was discovered. Coal then as pared to furnish anything made of Asbes sumed new duties as steam fuel. Later tos, Magnesia and related products, as the development of electrical power gave well as many other special articles for rail us another of. Nature's forces to use, and road and general industrial use.: in our use of steam, electricity add the in Johns-Manville Service: does not. stop, tense fires required by mdfistty^ wc. were constantly faced with the;-phpbie^'of:vcbn-. -trolling the tremendous^ to yy.'.lisd here. :At each^to fully ofgahized Gonst^ evoked. Asbestos has gtPtiy;;assisted: in , for the application of hUtlmaterials; This the solution ofHhis problemvf trough; in-' department includes- a sulations; packings; brake linings, toofings enced and competent engineers: and skilled --in innumerable ways* it enables us to - mechanics, thoroughly familiar with the' bend to man's service forces which - were application of our products. once- his, master. :: ^ Throughout the bo'ok will be found val Asbestos stands, unique---a world-old uable technic^}.: ffifoim^iom .relating^; to rock which is immune to* the action of ' our various hn|s| anfi;ifi::j:h4jt^.eiidixfis. . heatj water, weather and %ear^a fibrous. a collection of tables fif engipeeriiig data mineral which can ,be spun, woven, felted . which makes this: volume;`not-only a cata or molded into useful \fofm.\ ,So -closely log but ah.engineer's.handbook ^w^ 5 CRMC-003369 Johns-Manville Service to Railroads The Story of Asbestos Piece of crude asbestos, just as it comes from the mine, split to show the mineral fibres. ILLIONS of years ago this' earth' brittle, heavy as rock in its crude state, M; went through untold ages of flame, yet as light as thistledown when treated ; slowly; forrni-ng4 a-; marvelous' miri-mechanically. Through::all:the countless yeral---as. heavy and Ihehse hs marblea,geyse, tduring which the- hardest rocks sur '. literally a nugget of'silky fibre--ASBES rounding] it have been reduced, this min- TOS. eralogickl :mystery hab remained intact; A Asbestos Is one of the most remarkable : having; successfully resisted the assaults substances found in nature. Its unique of fiire;!acids arid time, / r- properties are unparalleled.: ' -Wood burns Asbestos is found in various parts Of the --Asb:estds;Is' unch;mge&bb^ ? wotld, but;pf unusually pure quality in our tenipefatures: of 1500 E;; " Stprie diS'im exterisive^riiines in thp: Province of Quebec, tegrafes^trAsbestps; defies Erosion. Steel Canada 'arid innChrysplile, rusts--Asbestos is immune; Asbestos is qiiarriedTri much the sarne It is b -peculiar species of the horn manner as stone; and, when it comes from blende family of minerals. Its composi the mine, looks like ordinary rock except tion is chiefly silica, magnesia and a that it has: a gray or dark green surface. small quantity of alumina, ferrous oxide After being mechanically treated the re and water. The fibres formed by this markable mineral fibres extracted from chemical combination are perfectly smooth the rock can be spun, woven and otherwise and non-tubular and in these respects are manufactured into many useful articles. different from all other known fibres. For centuries Asbestos was but a curi Paradoxically, it is the link which com osity--the mystic mineral, the paradox of pletes the chain between the vegetable ages. But today it is a recognized neces and the mineral kingdoms; it is in fact sity, developed by the efforts, the courage a mineralogical vegetable possessing the and the resources of those manufacturers curious properties found in both, for it is who, from the beginning, have recognized at once fibrous and crystalline, elastic and its possibilities. 6 CRMC-003370 Johns - Manville Insulating Materials 7 CRMC-003371 Johns-Manville Service to Railroads Johns -Manville Insulating Materials ORE horsepower from the world's M coal pile is one of the big problems of industry that touches us all. The economy with which coal is burned is as important in regulating the price of life's necessities as the cost of raw materials or the price of labor. But if saving coal means losing power the ultimate economy is doubtful. Hence, "More power delivered per pound of coal" is the aim of all industry as it strives for economy. "More heat delivered per ton of coal" is the aim of every fuel-user. perfecting of these heat insulations and their application to thousands of power plants, is saving power by saving fuel-- millions of dollars worth annually; nor does this include countless other installa tions on the heating systems of offices and buildings generally, where coal is burned for human comfort. Thirty years' specialization, directed by the highest engineering talent, has enabled Johns-Manville to develop and produce insulations of exceptional efficiency and durability under every service condition. . It is the growth of production---with its Asbesto-Sponge Felted, for example-- ; correspondingly greater needs-^that. has a remarkable: felt;: which combines the made one of; the most important results of : "dead-air cell" insulation of .sponge with the development. q.;;Asbestos b:^. Johns- the endurance of :asbestos-4is;rahked first . Manville, the saving, of heat.' through in in efficiency by independent investigators. sulation. Johns-Manville has developed materials,built yOh: asbestos as a base, that retard the escape of heat from boilers, Or 85<J0 Magnesiar^--or Improved Asbestocel, Zero, Anti-Sweat, or Brine; and Am- furnaces, pipes anbfiues--heat, energy that : monia Insulatiphs---whateyer your needs, would otherwise be wasted, 5: you can meet them efficiently with one pf the Johns-Manville Insulations - described Johns-Manville: Insulation Service, the on the following pages. 8 CRMC-003372 Johns -Manville Service to Railroads Insulation i HE real object of insulation is to pre An insulation that would allow no flow Tvent the flow of heat to the outside of heat through it would be 100 per cent, surrounding air from a boiler, appa efficient. ratus or pipe in which it may be generated, stored or conveyed, or to prevent the flow Material that offered no resistance to of heat from the outside to fluids or solids the flow of heat would have an efficiency which should be kept cool or at low tem of 0 (zero). peratures. The unit of heat is a B.t.u. (British thermal unit)--just as a gallon is a unit of liquid measure, a foot a unit of linear measure or an ampere a unit of electrical current flow. The two examples above are the two ex tremes that do not exist, but the 100 per cent efficient insulation is nearly obtained by the application of any one of several Johns-Manville forms of insulation. The flow of heat from the fluid in a bare , or insulated; pipe; to . the; outside surround ing air-is measured by the number of heat :uhits, :that"fc walls of; the. .pipei.;or'insulation,mbhoth, :and: is usually The efficiency of an insulating material is expressed by a percentage which is the , per cent saving which - would be; effected. by insulating a pipe with that material Over what would heJost if the pipe were expressed in the number of B .t.u; that flow left bare or uninsulated. 1 through an area of one square foot in one hour---(B.t.u;. per square: foot pet hour). The efficiency, per .cent is obtained ; by subtracting the heat loss of the insulated'/ The rate of flow through .a certain.thick- pipe from the heat loss -df the; uninsulated ness and at a certain; difference in temper or bare pipe and dividing the difference by ature determines. the conductivity of the: the heat loss from the bate pipe. See How material through which the heat flows, A to Use Efficiency Tables on page 248 of smaller number of heat units flow; through Appendix. a given thickness of a material with a low conductivity than through one with a high On the following pages are tables and conductivity. technical data pertaining to Johns-Man The relative efficiencies of various in ville Insulations, and on page 253 of Ap sulating materials may be appreciated by pendix is table showing thickness of steam comparing their conductivities under sim pipe insulation recommended for various ilar conditions. temperatures and pressures. 9 CRMC-003373 Johns-Martville Service to Railroads Johns-Manville Asbesto - Sponge Felted Sectional Pipe Insulation The most durable, efficient and adaptable in sulation known for insulating pipes conveying steam at high pressures and temperatures. QHNS-MANVILLE Asbesto - Sponge necessary it can be removed from the pipes J Felted Insulation is made of layers of and replaced . without.;; injury,'.: : thin felt, composed of asbestos.;fibre.-and ; . Expansion and con.traction: of pipes will papticies pf finely ground, spopgy material not wear, away; or harm the inside, of Ast - forming an extremely cellular felt, built besto-Sponge Felted Insulation. Because : up like a book in laminated form, thereby of its durability^ adaptability and' perma . ' confining: a: large.Volume. of minute dead nent efficiency it provides exceptional eco- :S.ir cells in thedelt and. between ;the layers. ; ;nomy. -. Sections .arelcut entirely through Johns-Manville Asbesto-Sponge Felted on one side only/ which is a distinct ad . ; : Insulation possesses hot only very -high vantage From ah"ins ; initial efficiehcy as- sh6wn on thefollow-: Johns-Manville rAabesto-Sponge Felted ing -pages* but permanent efficiency year Sectional Pipe. Insulation is- furnished in after year because of: its" extremely dur thicknesses;.from,^"-;tQ 3",'in 3-foot sec able construction. Because of its construction, and unlike insulations of the molded type, Johns- tions with canvas jacket and brass-lac quered bands, to fit standard pipe sizes. Specifications for insulating with JohnsManville Asbesto-Sponge Felted Insula Manville Asbesto-Sponge Felted is tough, tion will be found on page 13. flexible and practically indestructible. Also furnished in sheets and blocks for Pipe vibration, and the general wear and boilers, flues and other large regular sur tear to which insulation is subjected, will faces, Sheets 24" x 36" and blocks 6" x not pulverize Sponge Felted Insulation 36", in thicknesses from to 4". or break it away from the pipe. Even if For descriptive data on this insulation subjected to excessive moisture or satu in sheet and block form, see page 39. rated with water it will dry out and See approximate weights and price list regain its initial efficiency. Whenever on page 32. 10 CRMC-003374 Johns-Manville Service to Railroads Johns-Manville Asbesto-Sponge Felted Train Pipe Insulation WEATHERPROOF ASBESTOS. FELT JACKET FOR. TRAIN PIPE INSOLATION ................ ...........................Ouant.tv of Weatherproof . Size of,.-.- -Asbestos :Felt required per Pipe ., 100 lin:- it. of pipe, with stan- Lin. ft. * 'A" .......................................... ... 42 . Va" ............... ...45 I" : ... . 47 iVa" .................................. ... 50 i Vi" .......................................... ... 53 .2" .......................................... . . . 58 VA" 3" 354" 4" .......................................... . . . ....................................... . . . .......................................... . .. ........................................ . . . 64 70 75 81 w.......................................... ... 86 5" ........................................... 6" .......................................... . .. 104 r .......................................... . . . 115 3" .......................................... . . .125 9" .......................................... ...140 10" .......................................... ...149 Sid. 32" wide. . > Squares 1.04 1.11 1.15 1.23 1.31 1.43 1.58 1.73 1.88 2-00 2.12 2.30 2.57 2 84 3.11 3.46 3.68 -Pounds of. Wo: 1X5 (B. & S.) Copper Wire per 100 - - Jin. ft. 1.70 1.85 '.2.00 ' 2.13 2.23 2.42 2.64 2,90 3.13 3.34 3.56 3.80 4.24 4.70 5.12 5.54 6.02 11 CRMC-003375 Johns-Manville Service to Railroads Comparative Efficiencies of 1-inch Asbesto-Sponge Felted and s/8-inch Indented Insulations on 10-Car Train Example showing saving effected by using insulation of correct thickness and high efficiency on train pipes RAIN pipes are frequently insulated Twith an insufficient thickness of insulation and furthermore the insula- The following data show the economy of using the correct thickness of highly efficient insulation. The slightly greater tion used is often not of the most efficient first cost is repaid many times over by the type. saving effected. Number of Cars--10 Length of Pipe Per Car--70 ft. of 2" pipe; 20 ft. of 1" pipe Steam Pressure in Pipe--40 lbs. per sq. in. (gauge) Steam Temperature in Pipe 287 F. Average Air Temperature surrounding Pipes--30 F. Temperature Difference--257 F. Efficiencies in Still Air at 257s Temperature Dif ference: 1'' Pipe 2" Pipe Standard Thick fg" Thick Asbesto-Sponge Felted Indented . ... 81.48% ..................................................... 65.78% .... 84.55% ...................................................... 71.06% Heating Value of Coal--10,000 B.t.u. available per pound. (This is very conservative as it is equivalent to a boiler efficiency of about 70% and coal with 14,000 B.t.u. per lb. Both the boiler efficiency and the heat ing value of coal are high and with lower boiler efficiency or lower heating value, the pounds of coal saved, would be even greater than given in the table.) Ajr Velocity*., ,.. Miles per' hr;, Losses 'V : B.t.u/;Per Linear Ft. Per Hour . , . 'insulated with:-;1 /Standard, T-hick Aibestd-Sponge Felted1 . ... ..Thick '. ' Indented ..Additional. Saving by. Asbesto-Sdonge Felted, as compared ..with Indented. B:t.u. ..Per; Linear;; . . Saving 'Per Hour : Ft. Per Hour . on 10-Car Train ' . 25 -so . . Pipe Size Xv'T/x,;:/ .2 Pipe Size . 1" 2": ' Pipe Size. ' v ; ';,r '2X . B.t.u. Lbs. Coal' .X ... / 49;7 r-. .7-4-1 91.8' . 138.9 . 42.1 ' - 64-.8'.' / : `"53,78d . 5.38. - 5,9.6 : 89.4 : ' 124.0 . 193.5' - 64.4; 104.1, . 85,690 : 8.57 . 60.0 . - 90.0 . 126.2 19.8.3 66.2 : 108.3 89,050 8.90 ; Air.Velocity .may; be.,,due. ejtlje'r'.fo wind, when train,;is standing,..:pr'to motion.;of. train,';.with reference to surrbu.ndirig..atr; ' ' r- : :V. Note the large' saving pri; a 10-car train insulated.... with .Standard Thick JohnsManville Asbesto-Sponge Felted as com pared with %" Indented Pipe Insulation. This saving amounts to 53,780 B.t.u. each hour or 5.38 lbs. of coal in still air and is increased to 85,690 or 8.57 lbs. of coal each hour that the air velocity is 25 miles per hour. From the above table the value of the saving may readily be computed for any number of hours operation per year and any price of coal. For example, assuming 4000 hours operation per year with an average air velocity of 25 miles per hour, the saving would be equivalent to 85,690X4000 _ _ ,,V io.oooxSooo^7-14 tons of coal which at $5.00 a ton is equivalent to $85.70. Based on a list price of insulation of $306.00 for the 10-car train and about 15% of list difference between Asbesto-Sponge Felted and Indented the difference in cost amounts to $45.90. This means that the extra cost of the Asbesto-Sponge Felted will be paid for in 3 months of the first heating season and that each year there after the Asbesto-Sponge Felted gives a clear saving of $85.70 more than the In dented. 12 CRMC-003376 Johns-Manville Service to Railroads Standard Specifications for Insulating Steam Pipes with Johns-Manville Asbesto-Sponge Felted Sectional Insulation All live steam and feed water piping shall be insu- Sectional Insulation applied in different thicklated with Johns-Manville Asbesto-Sponge Felted nesses for different classes of piping as follows: Steam Pressure or Condition Steam Temperature Thickness of Insulation Pipes larger Pipes Pipes than 4" 2" to 4" y3" toV/3 SUPERHEATED STEAM PIPING High Superheat ........................................................................ 600 to 700 F. Superheat .....................................................................................500 to 600 F. 3"* 254"* 3" 254 " 2" 2" * In addition to sectional insulation, Johns-Manville Insulating Cement l/3" thick is to be applied over the Asbesto-Sponge Felted Insulation on pipes larger than 4" HIGH PRESSURE (OR LOW SUPERHEAT) STEAM PIPING Higher than 200 lbs. (or low superheat).......................388 to 500 F. 1Q0 to 200 lbs. ........ ........................ .................................... .. .338 to 388 F, 254" 2" 2" 154" 154" 1" MEDIUM PRESSURE STEAM PIPING 25 to 100 lbs................................................... ............................. ;267 to 338 F. . 1^4" ' . ' 154" 1" ; : LOW PRESSURE STEAM AND FEED WATER PIPING Oto 25 lbs. ................. .................. .......................................... 212 to 267 F. 'Feed .Water' Piping-' . .W.-v. ...V........ ... ''I" ' i"- 1" . i"- 1" !; -1" Superheated Steam Piping The insulation for superheated steam piping shall be applied in at least, two layefs .to'make up the. total thickness required,; as specified' above. The first layer shall be applied to the piping with out canvas jacket and be secured in place: with annealed iron, wire wrapped. around, its circum ference and fastened on at intervals of 6". [All joints in the insulation.shall be sealed during ap plication with Johns-Manville Insulating Cement. These joints shall be filled with cement as the sections are applied and the sections shall then be tightly drawn together by means of the wires referred to above. Any cement protruding from the joints shall be plastered back with a trowel.] The second or succeeding layers shall be ap plied as described above and shall be so placed . that all joints in adjacent, layers are broken or .staggered. Canvas jacket js -to be ofnitted, except on outer layer of. insulation on: .pipes., 4" and smaller. . . :;;V On all pipes larger than. 4" after the sectional insulation has been applied as specified above there shall be applied over this a finish of JohnsManville Insulating Cement J4" thick applied in, two coats and troweled to a smooth and uniform surface. Where the cement finish is not used it is more than ever essential that all joints be well sealed as the purpose of this cement finish is to make certain that there are no open joints through which heat can be lost. High Pressure Saturated Steam Piping (or Low Superheat) The insulation for high pressure steam piping, where thickness is 2" or more, shall be applied in two layers to make up the total thickness as given above and, where thickness is 1y2" or less, in a single layer of the required thickness. The can vas jacket shall be omitted from the first layer where insulation is applied in two layers. All joints shall be cemented and the insulation shall be secured in place with wire in the same manner as specified for superheated steam piping. 13 CRMC-003377 Johns-Manville Service to Railroads Low Pressure Steam and Feed Water Lines The low pressure steam and. feed water pip- This insulation shall be applied with joints ing shall be insulated with a single layer of closely drawn together and canvas jacket pasted the required thickness, as given hereinbefore, down. Fittings and Flanges The bodies of all flanged fittings and all screwed fittings, including valves of the larger sizes (4" and over) shall be insulated with block and cement insulation of the same material and thickness as is used on the pipe lines on which they occur. The block insulation shall be securely wired in place with annealed iron wire and all joints shall be filled with insulating cement. The insulation shall be finished with Johns-Manville Insulating Cement troweled to a smooth and uniform surface. All fittings smaller than. 4" in size shall be insulated with Johns-Manville Insulating Cement applied in layers, each about ^4" thick, to the same total thickness as the adjacent pipe insulation. Each layer of this cement is to be allowed to dry before the. next layer is applied and each layer, except the last,, is to be applied with a , rough surface. The last layer is to be troweled to a smooth and uniform surface.- . Flanges may be insulated with either a perman- ent or removable and replaceable type of insulation. The permanent type of insulation shall consist of a built-up block and cement insulation constructed of the same material and of the same thickness as the adjacent pipe insulation and applied as described above for fittings, The removable and replaceable type of flange cover shall be of the same thickness as the adjacent pipe insulation and shall be constructed as follows: Use suitable size and length of Johns-Manville Asbesto-Sponge Felted Sectional Insulation to completely encircle flange and overlap the adjoining pipe insulation at least 2" on each side of the flange. Secure this flange insulation, with wire and fill the space between the pipe and flange insu'ation with Johns-Manville Insulating Cement and apply a thin coat of Johns-Manville Insulating Cement over the entire surface of the : flange cover. Finish of Insulation ... After .all. insulation, has been., completely, ap are-to be located where least visible. plied and all cement surfaces troweled to a This canvas jacket shall be painted with first smooth.and uniform finish, apply over all insula-; a coat of sizing and then with two coats of fire tion on piping and,fittings an additional jacket of. proof paint or lead and oil paint of color desired. 8 oz; canvas. This jacket is. to be .sewed on dyer, :(Where re-canvasing is not desired or is con a lining of heavy, rosin-sized paper,, and all, seams sidered unnecessary, see Note B.) \ \':V Weatherproof jacket If piping is located out of doors and is expbsed . ends twisted tightly together. . These wire rings to the weather the additional protectiomOf 8 oz. are to be placed on A" centers. The jacket is to canvas and paint may be omitted and in its place lap at least 3" in all directions and all horizontal the insulation shall be protected with a Johns- laps are to be located on the side of the insulation , Manville Asbestos Weatherproof: Pipe Insulation and turned downward in order to shed, all water jacket, secured with rings formed of No. 16 from the surface. Copper Wire wound once around the jacket and NOTE "A": Johns-Manville maintains an Engineering Department at each of its Branches, which will on request recommend proper thick nesses of insulation for various special conditions. NOTE "B": The light canvas jacket regularly furnished with the insulation shall be neatly pasted down over all laps. The pipe insulation shall be additionally secured in place with brass lacquered bands furnished with the material, p'aced at suitable intervals at least two bands per section of pipe insulation. All cement surfaces shall be finally finished with a jacket of light canvas neatly and securely pasted on. NOTE "C": When extremely low tempera tures are encountered out of doors special recom mendations will be given by any Johns-Manville Branch Engineering Department. 14 CRMC-003378 Johns'Mairville Service to Railroads What Insulation Efficiency Means HE efficiency of an insulating mate Trial is expressed by a percentage, which is the per cent of heat saved ence in temperature between steam in the pipe and air surrounding the pipe, as well as according to thickness of insulation. by using the insulation as compared what would be lost if no insulation were used and the pipe left bare or uninsulated. toComplete of efficiency information tables with regarding the use examples to illus The efficiencies of all insulations vary trate will be found on page 248. according to the size of pipe to which they For table showing total heat loss from are applied and according to the differ bare pipes, see page 249. EFFICIENCIES OF STANDARD THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE Pipe Size. Temperature Difference Between Steam in Pipe and Air Surrounding Pipe Inches ,-.0 100 150 200 < 250 300 360 Per. Cent.. Efficiencies oo 450 500 54...-:.............. .. Ya....................... I ........................ ............... ............... ............ 68.5% . 71.2% 71.9 . 74.3 74.3 ' ,. 76.5 ;. 73.3% 75.5 % 76.2 . 78.1 ' 78.2 ", ; ,79.9 77.1% 79.6 81.3 78.7% 81.0 .82.6 80.4% 82.6 84.0 . 81.9% .83.8 ; 85.2' 83.1% .85 0 . '86.2 84.5% 86.2 -87.4 - P'.':. . 11;. , 2 .................. ..........:. . 75.7 77.0 .. .......... L : 78.6. ' 77.7 .' 79.5.. !' 81.0 82.3- 79.0 . . 80,5'. . 82.0 ; ' 83.2 .80,4 " 81.9 83.3 . .84.4. 83.5 84.4 , 85.5 84.9 ' 86.0: 86.9 85.7r . 86.7.V 87.6 86.7 - 87.6 , .88.5 ; . 88.0 88.8 89.3 ....... ...... 79.8 3 ........................ ............ : ' 80.6 ' Si'...:.......... .......... 81.2 V" .'.............81.8 'J ........:.vL.. ........82.1 , 5" , ........ ''82.-3 81.5 82.2 .' 82.8 82.9 .. 84.3 8S.6 ; ' 64.9 - 84.1 . 85.4 ; I-83;8 . 84.5 ' 85.8 ' : 83.6 ' . 84.8 . : 86.0 , ; 83.8 1 ' 85.0 56.2 85.3 85.9 86.3 86.7 87 Q.. 87.1 , 86.3 86.8 . . ,87.3 .87.6 87 9 88.0 87.5 87.9 83.4. 88.8 89.2 89.6 90.0 90.3 88.3 89.2 ' 89.9 90.6 : 88.7 . 89.5 f. .. 90.2 '. . 90.0 . 889 89.7 90 4 ' 89.0 , . . : 89.8 , ' ; . 80.5 ... 91.1 91.2 :3 V............ . ........... 82.7 ' 84.2 ; 7 . ........ 83.0. ; 84.5 ' 3 ' '.i'-;-.... 83.4 ; !- ; 84-8 109' '. .. . . .:83.5 ___ ............. . 83.8 84.01..' . ;85.i\ . 85.4 : 86.6 . 85.9", . 86.5 86.8 : 87.0 86.6' : 87.2 86.2; ; 87;3. 87.487.6.' 87.9 88.0 88.2, V 88.3 : 88.5 - 88:7 8:8 8 ; 89.0 89.3 . 89.5 ; 89.7 69.8.' 89.9 ' - 90.1 ' 90.7 96.2 W : - 90.9 '90.4 ' 9i:i , '. 80.5 \ V 91.2' .; '90.6: ( v , 91.3 -. : 91.4 91;6 91.7 .91.8 91.9,-. EFFICIENCIES OF 154'" THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE Pipe Sizes Inches 60 Ya............................... 1 ............................... ............... ............................... .............. M4............................... 2 ............................... .............. *14............................... 3 ............................... ............ 3'A............................... 4 ............................... ............... 4 ^............................... ............... 5 ............................... .............. 6 ............................... 7 ............................... ............... 8 ............................... ............... 9 ............................... ............... 10 ............................... ............... 76.1 77.8 81.0 03.0 84.2 84.6 85.0 e* 9 86.2 86.4 86.6 ... Temperature Difference Between Steam in Pipe and Air Surrounding,-Pipe `100 ; 150 200 250- 1 '300' 360 400 450 72.9% 75.9 78.1 79.7 80.7 82.7 83.7 84.5 85.0 85.5 85.9 86.3 86.7 87 1 87.5 87.7 87.8 75.0% 77.7 79.6 81 2 82.3 64.0 85.1 85 7 86.2 86.7 87.1 87.4 87.8 88.1 88.4 88.6 88.8 76.8% 79.4 61.3 82.5 83.5 85.2 86.1 83 a 87.2 87.7 88.0 88.3 88.6 89.0 89.1 80.3 89.6 Per Cent. Efficiencies 78.4% 83 9 82.7 83.0% 82.4 84.1 81.5% 83 5 85.1 83.8 84.7 86.2 85.1 86.Q 87.2 86 1 86 9 88.1 87 0 87.7 66.1 88 1 88 7 89.1 88 8 89.4 89.8 83 5 88.8 89.1 89.5 89.8 90.0 90.1 90.4 90.6 89.4 89.6 93.0 90.3 90.6 90.8 90 9 91.2 91.4 00.1 93.3 90.9 91.0 91.6 91. G 82.9% 84.9 86.3 87.2 88.0 89.1 89.8 90.3 90.6 91.0 91.2 91.4 91.7 91.9 92.1 92.2 92.3 84.2% 86.0 87.3 88.2 88 8 89.9 90 5 91.0 91.3 91.6 91 8 92.0 92.2 92.6 92.7 92.6 92.9 600' 85.2% 87.0 88.1 690 89.9 90.6 91.1 91.6 91.9 92.1 92.3 92.5 92.7 92.9 93.1 93.2 93.4 15 CRMC-003379 Johns-Manville Service to Railroads EFFICIENCIES OF 2" THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE Pipe Size, Inches 50 54............................... .............. yA............................... .............. l ............................... .............. VA............................... .............. 154............................... .............. 2 ............................... .............. 2 54 ............................. .............. S ............................... .............. 854............................... .............. 4 ............................... .............. 4>4 ........................ .............. G ............................... .............. 6 ............................... .............. 7 ............................... .............. B ............................... .............. 0 ............................... .............. 10 ............................... .............. 73.2% 76.5 78.8 80.5 81.7 US.6 84.3 85.6 86.2 86.7 87.1 87.5 88.0 88.4 88.6 88.0 89.1 Temperature Difference Between Steam in Pipe an d Air Surrounding: Pipe 100 150 200 250 300 850 400 450 Per Cent. Efficiencies 75.6% 78.6 80.7 82.0 83.4 85.1 86.1 86.6 87.4 87.9 88.3 88.6 89.1 89 4 89.6 89.9 90.1 77.5 % 80.3 82.2 83.6 84.7 86.2 87.2 87.9 88.4 68.8 89.2 89.5 89 9 ' 90.2 90.4 90.6 90.8 79.2% 81.8 83.6 84.9 85.9 87.2 88.2 88.8 89.3 89.7 90.0 90.3 90.7 91.0 91.2 91.4 91.5 80.7% 83.1 84.8 86 0 86.9 88.1 69.0 89.6 90.1 90.5 90.7 91.0 91.8 91.6 91.8 92.0 92.2 82.0 % 84.2 85.8 87.1 87.8 89.0 89 7 90.8 90.8 91.1 91.3 91.6 91.9 92.2 92.4 92 5 92.7 83.5% 85.5 87.0 88.0 88.7 89.9 90.5 91.1 91.5 91.8 92.1 92.3 92.6 92.8 93.0 93.1 93.3 84.6% 86.5 87.8 88.8 89.5 9D.6 91.2 91.7 92.1 92.4 92.6 92.8 93.1 93.3 93.4 93.6 93.7 86.1% 87.8 89.0 89.8 90.4 91.4 92.0 92.5 92.8 93.1 93.3 93.5 98.8 94.0 94.1 94.2 94.3 500 87.4: 88.8 90.0 908 91.2 92.1 92.7 93.2 93.5 93.7 03.9 94.1 94.8 94.5 94.6 94 7 94.8 EFFICIENCIES OF 2^" THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE Pipe Size, Inches 50 - Temperature Difference Between Steam in Pipe and Air Surrounding Pipe 100 150 200 250 300 350 Per Cent. Efficiencies 400 450 t/j. . ...................75.0% y4:............. .................. 78.2 1 ........ ..............80.5 77.3% . 78.9% 80.0 81.6 82.2. : .. 83.5 VA-':.'............. ................... VA ................ 2 . . :............ .............. 82.2 ` 83.4 ' ' 85.2 83.8 . 84.9 84.9 - 86.0 86.5 : .. 87:5 > . nyt.. ............... . .............. ' 86.3 3 ..........: .;............' 87.1. V; VA'.:............ ............-87.8 87.5 88.3 : 86.9 : ;. 88.4 : : 89.1 '. 89.7.:.-: .:..........\ 88.3 '' !4 y:.;.......... ' 6 ___ ............ 89.0 ' 89.3 / 90.1 - 89.7 ` . 90.4 - 90.0 ' 90.7 : 6 'v.\. 8 ___ : 89.5 V................ ' 89.9' ............ 90.1'-' ' 90 4 ' 90.8 ' .91.0 91.1 ' 91.4.. 91.6 91.2 > -91.8 . 10 .. ......... : 93.5 . .91.4 92.0- 80.7% 83.2 85.0 86;2 87.2 68.6 89,4 . 90.1 : 90.6 90.9 91.2 91.5 91.9 92.2 92.4 92.5 . 92.7 82.1% 84.4 86.0 87.2 88.1 89.4 90.2 90.3 91.2 91.6 91.9 92.0 92.0 92.7 92.9 : 93.1 . 93.2 ' 83.7% 85.7 87.2 88.3 89.1 90.3 91.0 91.6 92i0 92.3 92.6 .92.8 93.1 93.4 : 93.5 93.7 : 93.8 84.8 a 86.7 88.1 ' 85.9% . 87.7 89.0 > 69.1 89.9 . 91.0 90.0 ' 90.6 91.7 . 91.7 92.2 92.6 92.3 . 92.7 . .-. 93.1 . 92.9 93 1 93.3 93.4 93.6 - 98.6 ' 93;6. 93.8. 94.0 94.1 : 94.3 ' 94.4 94.1 94.6 ... .,,94.2' "" 94 7 ; 87.0%. 88.5 89.7 90.6 91.2 92.2 92 8 93.2 93.5 93.8 94.0 . 94.2 94 5 .94-7 94.8 94.9 95.0 500 88.0% 89.8 90.4 913 91.9 92.8 93.3 . `. 93.7 94.0. 94.3 ' 94-5 94.6, . 94.8 95.0 ' 95.1 95.2 95:3 ' EFFICIENCIES OF 3-- THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL . PIPE INSULATION ON VARIOUS SIZES OF PIPE Inches' 54................ 3/4................ 1 ................... 1*4................... 1}4................... 2 ................... 2 Vr................... 3 ................... 3%................... 4 ................... iy2................... 5 ................... 6 ................... 7 ................... 8 ................... 9 ................... 10 ........................ ........................ ........................ ........................ ....................... ........................ ........................ ........................ ..................... ....................... ....................... ........................ ........................ ....................... ....................... ....................... .. . Temperature Difference Between Steam in Pipe and Air Surrounding Pipe 50 100 150 200 250 300 350 400 Per Cent. Efficiencies 76.8% 79.7 81.9 83.5 84.7 86.5 87.5 88.4 89.0 89 5 89.9 90.2 90.7 91.1 91.3 91.5 91.7 78.9% 81.7 83.5 85.0 86.3 87.7 88.7 89.5 90.0 90.5 90.8 91.1 91.5 91.9 92.1 92.3 92.5 80.6% 83.1 64.8 66 2 87.2 88.7 89.6 90.3 90.8 91.2 91.5 91.8 92.2 92 5 92.7 92.9 93.0 82.1% 84.5 86.1 87.3 88.3 89.6 90.5 91.2 91.6 92.0 92.2 92.5 92.9 93.2 93.4 93.5 93.G 83.4% 85.6 87.1 88.2 89.1 90.3 91.1 91.7 92.1 92.5 92.8 93.0 93.3 93.6 93.8 93.9 94.0 84.6% 86.6 88.0 89.1 69.9 91.0 91.7 92.3 92.7 93.0 93.3 93.5 93.8 94.1 94.2 94.4 94.5 85.8% 87.6 68.9 89.9 90.6 91.7 92 4 92.9 93.3 93.6 93.8 94.0 94.3 94 5 94.7 94.8 94.9 87.0% 88.6 89.8 90.8 91.4 . 92.4 93.0 93.5 93.8 94.1 94.3 94.5 94.8 95.0 95.1 95.2 95.3 450 . 88.1 69.6 90.7 91.6 92.2 93.1 93.5 94.1 94.4 94.6 94.8 95.0 95.2 95 4 95.5 95.6 95.7 500 89.1% 90.5 91.5 92.8 92.6 93.7 94.2 94.6 94.8 95.1 95.2 95.4 95.6 95.8 95.0 96.0 96.1 16 CRMC-003380 Johns-Manville Service to Railroads Johns-Manville 85% Magnesia Sectional Pipe Insulation For the insulation of pipes conveying steam OHNS-MANVILLE 85';% Magnesia nesses from standard (approximately V J Pipe Insulation combines the high nonconducting qualities of carbonate of thick) to 3" thick, in 3-foot sections with canvas jacket: and brass-lacquered bands, magnesia and asbestos, affording a light, to fit standard pipe sizes up to and includ- efficient insulation. Under; actual service- ing 12" in diameter;. For larger pipes,: conditions, Johns-Manville 85% Magnesia curved segments or blocks are supplied, has proven itself to be the most durable and efficient insulation of . the ' moulded ' Also furnished in blocks for covering type. The Johns-Manville manufacturing/ boilers> boiler flues and other large regular process produces an 85% Magnesia with and irregular surfaces, such as steam and the, maximum number of voids or minute receiver pipes on Mallet _ locomotives, dead-air cells which increase its natural Blocks 3- x 18 or 6. x 36 , in thicknesses resistance to heat transmission and reduce from % to 4 . its weight. In addition, this process pro- Specifications for the application of vides maximum mechanical strength con- Johns_ManviUe 85% Magnesia Insulation sistent with high efficiency. wm be found on the following page. The efficiencies of Johns-Manville 85% For descriptive data on this insulation Magnesia are given on pages 19 and 20. in sheet and block form, see page 40. Johns-Manville 85% Magnesia Sectional See approximate weights and price list Pipe Insulation is made in various thick- on page 32. 17 CRMC-003381 Johns-Manville Service to Railroads Standard Specifications for Insulating Steam Pipes with Johns-Manville 85% Magnesia Sectional Insulation All steam piping shall be insulated with JohnsMahville 85% Magnesia Sectional Insulation of proper size and thickness, with all joints sealed with Johns-Manville Insulating Cement. (See note "A".) The bodies of all flanged fittings and all screwed fittings, including valves of the larger sizes (4" and over) shall be insulated with block and cement insulation of the same material and thickness as is used on the pipe lines on which they occur. The block insulation shall be se curely wired in place with annealed iron wire and all joints shall be filled with insulating cement. The insulation shall be finished with Johns-Man ville Insulating Cement troweled to a smooth and uniform surface. All fittings smaller than 4" in size shall be in sulated with Johns-Manville Insulating Cement applied in layers, each about thick, to the same total thickness as the adjacent pipe insula tion. Each layer of this cement is to be allowed to dry before the next layer is applied and each . layer, except the last, is to be. applied with a - rough surface.. The last layer is: to be troweled to a smooth and uniform surface. % All flanges shall be insulated by method "A" or "B," depending upon whether flange insulation is to be removable and replaceable or non-replaceable. Method "A"--Use No. 19 half-inch mesh gal vanized iron wire netting for forming frame for the removable and replaceable flange. This wire mesh should be cut into two pieces of such a size that each piece will encircle onehalf (*4) the flange, and with the ends turned down so that they will meet and come in contact with the insulation on the pipe. Attach to this wire mesh frame Johns-Man ville 85% Magnesia blocks or sectional insula tion of proper size and length and wire in place with wire lacing. Apply on the ends of this removable frame Johns-Manville Insulating Cement of the same thickness as that of blocks or sectional insula tion, then apply, over entire surface of flange cover, one-half inch finish of Johns-Manville In sulating Cement. Method "B"---Apply built-up block and cement. insulation of the same material and of the same thickness as tlie adjacent pipe insulation, as de scribed above for fittings. ./.: /. - Finish of Insulation All of the. above insulation, including fittings, valves and flanges, shall. beTfirially. finished and additionally protected with 8-punce .canvas,.neatly'served, on,-over.rosm-sized. paper, and this canvas painted either with fireproof paint, or lead and oil paint, of the color desired, ...This, extra canvas covering to be placed over the canvas jacket furnished with this insulation. (When re canvasing is not. desired or considered unnecessary, see note "B.") Weatherproof Jacket If piping is Ideated out-of-doors and exposed to the weather, the additional protection of 8ounce canvas and'paint may be omitted and in its place the insulation shall be protected with a Johns-Manville. Asbestos Weather-proof Pipe In sulation Jacket secured with rings formed of No. 16 copper wire wound once around the jacket and ends twisted tightly together. These wire rings are to be placed on four-inch (4") centers. The jacket is to lap at least three inches (3") in all directions, and all horizontal laps are to be located on the side of the insulation and turned downward in order to shed all water from the surface. (See note "C.") NOTE "A"--Johns-Manville maintains an en gineering department at each of its branches, which will, on request, recommend proper thick ness for various pressures and temperatures. NOTE "B"--If insulation is not to be re-canvased, lacquered bands furnished with the insula tion are to be applied, at 18" intervals, on all sectional insulation. NOTE "C"--When extremely low tempera tures are encountered out-of-doors, special re commendations will be given by any JohnsManville Branch Engineering Department. 18 CRMC-003382 Johns-Manville Service to Railroads What Insulation Efficiency Means HE efficiency of an insulating ma Tterial is expressed by a percentage, which is the per cent of heat saved by using the insulation as compared to what would be lost if no insulation were used and the pipe left bare or uninsulated. The efficiencies of all insulations vary according to the size of pipe to which they are applied and according to the difference in temperature between steam in the pipe and air surrounding the pipe, as well as according to thickness of insulation. Complete information regarding the use of efficiency tables with examples to illus trate will be found on page 248. For table showing total heat loss from bare pipes, see page 249. EFFICIENCIES OF STANDARD THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPES Pipe Size, Inches Temperature Difference Between Steam in Pipe and Air Surrounding Pipe 60 100 150 2003 250 300 350 400 450 % ...................... . .................... %............... .......... 1 .......................... -........... . . 56.1% 6s.6 65.8 61.7% 66.8 : : 68.7 : ' 64.8% 68.6 71.2 '/ 2 -.-................... ........................; G7 7 - 70.3 : 69.6 ' 72.1- 74.3 76.7 i " 72 9 74.3 78.6 ' 2"4-", ....................__________ : "3 .......... ..................... . sy2:,; 75.8 78.0. ' ' 7b.7 ; ' 78.8 . ... 77.4- ' . 79.5 79.8 ' 80.6 : - 81.2 4 ........................................... . 5 ............ .;,,.i............ ____ ' 60.4 ' ' 83.7 . 01.0 81.7 82.0 82.3 83.1 ; 83:5 : 83.7 :6 .7 .8 9 io ................. .................... .......... .......... '.; .......... ...v............ .......... ____ ........ 81.4 82 0 : 82.3- _ . 82 5 : ' 82.8 " 82.7 ; 84.1 ' 83.4 ' 84.7 ' 63:7 . : - 85.1 84.6 ' 85.2 8.4.2.:- . 85.4 Per Cent. Efficiencies ' 67.9% 71.3 73.7 70.5% 73.7 75.9 75.1 76.4 . 80.5 77.2 78.3 . 82.1 ' . '81.6 82.3 -- 82.9 . . 82.9 . ' 83.6 84.2 84.5 : 84 6 85 0 85.8 83.0 86.2. 85.4 - 66:0 .86.2. . 86.4 87:1 87.3 . 86 4 : .86.5 87.5 87.6 72.7% 75.7 77.7 78 9 80.0. . 83.3 . 84.2 . 84 8 - 854 . 86.9 87 1 87.S 87.6 , 88 2 . .88.4 . 89:5 88.7 74.9% 77.7. 79.5 80.6 Bl:784.5 B5.5 80.0 86.5 88.1 88 3 88.4 88.7 89.2 .89.4 '83 5 89.6 76i8% 79.3 81.1 62.1 83.0 85.7' 1 86.7 ; -87.1 87.6 89.1 .89.3 89.4 - 89.7 90:1 90.2 - 90 3 90.4 78.7% - 81.1 82.6 83.5 84.4 87.0 87.9 ' :88 2 88.7 . 90.0 . 90.1 90.3 .90.5 . 90 91.1 - 912 . ,91.3 500 80.6% 82.7 84.0 85.0 85.7 88.2 88.9. 89.3 89.7 90.8 910 91.2 91.8 91.8 91.9 . .92.0 92.1 EFFICIENCIES OF \y2" THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPES Pipe Size, Inches 50 i/2 ............... I'a............................... ............... I ............................... ............ V/a............................... l'A............................... ............... 2 ............................... - -.......... 2'/,............................... ............... 3 ............................... ............... 3%............................... ............... 4 ............................... ............... 4 J4............................... ............... 5 ............................... .............. C ............................... ............ 7 ............................... ............ 8 ............................... ............... 9 ............... 10 ............................... ............... 63.4% 7C.S 73.0 76 3 78 o ,-:9.8 80.8 81.6 82 1 82.6 80.0 61.5 84.1 54.4 84.G 84.9 Temperature Difference Eenveen Steam in Pipeand Air Surrounding-Pipe 100 150 200- 250 300 350 400 450 Per Cent. Efficiencies 69.4% 72.8 75.3 77.1 78.2 80.5 81.6 82.5 83.0 83.6 64.1 84.5 85.0 85.4 85.8 86 0 86.2 71.8% 74.9 77.3 78.9 80.0 82.0 83.2 83.9 84.4 85 0 85.4 85.8 66 2 86.6 86.9 87 1 87.3 74.2% 77 1 79.2 80.6 81.7 83.6 84.6 65 3 65.8 66.3 86.7 87.0 87 3 87 C 87.9 88 1 86.3 76.2% 79.0 81 3 02.2 83.2 84.8 B5.7 86.5 86.9 87.3 87.7 88 0 68.3 88.8 88.9 89.1 80.2 76.1 o 80.6 82.5 83.6 84 6 85.9 86.9 87.6 88.9 86.3 88.7 89.0 89.3 89.7 89.9 90 0 00.1 80.0% 82.2 84.0 65.0 85.9 67.1 88.0 86./ 69.0 89.3 89.7 90.0 90.2 90.5 90,t 93.9 91.0 81.7% 83.8 85.3 86.3 87.2 88.3 89.1 69.6 90.0 90.3 90.6 90.8 91.1 91.3 91.5 91.7 91.8 63.5% 65.4 86.7 87.6 88.5 89.5 90.1 90.6 91.0 91.3 91.5 91.7 91.9 92.1 92.4 92.5 92.6 500 85.2% 87.0 68.1 89 0 89.9 90.6 91.1 91.6 91.9 92.1 92.3 92.5 92.7 92 9 93.1 932 93.4 19 CRMC-003383 Johns-Manville Service to Railroads EFFICIENCIES OF 2" THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPE Pipe Size, Inches 60 Vi............................... a............................... 1 ............................... IK............................... VA............................... 2 ............................... va............................... 3 ............................... 854............................... 4 ............................... 4K............................... 5 ............................... 6 ............................... 7 ............................... 8 ............................... 9 ............................... 10 ............................... ............. ............ ............. ............ ............ ............. ............ 73.2 75.8 77.8 84.3 85.3 86.3 87.3 67.6 Temperature Difference Between Steam in Pipe and Air Surrounding Pipe 100 150 200 250 300 350 400 450 72.9% 76.0 ' 78.4 79.8 81.4 83.3 84.4 85.2 86.0 86.4 66.9 87.2 87.8 88.1 86.4 88.7 88.9 75.2% 78.S 80.4 820 83.2 64.8 65.9 86.7 87.2 87.8 68.1 88.4 88.9 69.2 89.4 89.7 89.9 77.1% 80.0 62.0 83.4 64.5 85.9 87.0 87.7 88.2 68.7 89.0 89.3 89.8 90.1 90.3 90.5 90.7 Per Cent. Efficiencies 79.0% 81.6 83.4 80.7% 83.1 84.8 82.3; 84.5 86.1 64 7 85.7 87.0 86.0 86.9 88.2 87.2 87.9 89.2 88.0 68.7 89.2 89.0 89.6 90.2 69.8 90.5 90.9 69.6 89.9 90.2 90.5 90.7 91.0 91.2 91.5 91.8 90.5 90.6 91.1 91.3 91.6 91.6 92.1 92.3 92.5 91.3 91.5 92.0 92.2 92.6 92.8 84.0% 86.0 87.3 88.4 69.1 90.2 90.8 91.4 91.8 92.1 92.3 92.5 92.8 93.0 93.1 93.3 93.4 85.3; 87.1 86.8 89.2 89.8 90.9 91.5 92.0 92.4 92.7 92.9 93.1 93.4 93.6 93.7 93.9 94.0 600 68.2 89.5 90.8 91.7 93.2 93.4 93.8 94.2 94.8 94.4 94.5 EFFICIENCIES OF 2*4" THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPE Pipe Si2e, Inches Temperature Difference Between Steam in Pipe and Air Surrounding Pipe 50 100 . 150 ; 200 250 300 350 400 450 Vi........................ .................... l Va........................ ....... ............ ................ ____ ..... 71.7% 76.4 78.0 74.6% 77.6,. 80.1 76.6%. 79.6 81.7 : . 1 Va................... .. 79.9 IK---...........- ......... 81.2 2 ........................ .. .................... : . 83.3 81.9 .. 83.1': 84.0. 83.2. ' . 84.5. ' 86.i: . VA..-......... . . ;____ . 3 ........................ ............ '85.4 VA..,.......... .. 84.5 86.2 . 86.0. 86.9.-': 87.6. , 87.1 87.9 , 88.6 . 4 .................. 86.8 VA.'.;.:............ .................... 87.2 5 ; . ............ . . ...... . , '87.6 88.0 '88.5. 88.8;-, 89.0 , 89.s; , 80.7,': G ............ ' '68.1 7 ....... ............... -........... 38.6 ''69.2-.. 90.1 89.7 " 90.5: 8 ! . ...................... -88.8 . 89.9. ' -90.7/ 9 ............ .. ____ " 89.0 90.1- / 90.9- '. 10 ........../ :..-rv;.89.3 / 90.4.:. 91.1;; 78.4% 81.2 83.2 84.5 85.7 87.2 sail 88.9 89.5- 89 8 90.2 90.5 90.9 9i.3 : 91.5 91.6 91.8 ; Per Cent Efficiencies 80.3% 82.8 84.6 82.1% 64.3 85.9 83.6% 85.6 87.1 86.9 85.9 88.3 - 86.0 87.1 . 89.3 89.1 . 86.2 .90.3 .... 89.1 89.9 90.3, 90.1 90.8 91.2 91.0: 91.6 92.0 ' 90.7 91.1 91.3 91.6 91.9 92.1 92.3 92.5: . 92 8- 91.7 92.0 92.2 92.4 92.6 . 92.8 ' 93.1 ' 93.3 93:5 92.4 92.5.; 93.1 93:2 93.6. ' 93.7 : 84.9% 86.8 88.2 89.9 89.3 91.0 91.8 92.2 92.6.; 92.9 93.2 93.4 93.7 93.9 ` 94.0 94;1 : 94.2' 86.3; 87.9 89.2 90.8 90.1 91.8: - 92.5 92.9 93.2 '93.5 93.7 . 93.9', 94.2 94.4 ; 94.5' 94.6'. .94.7.` 500 87.7% 89.1 90.2 91 7 91.1 92.6 93.2 93.6 93.9 . 94.2 94.4 : 94.5 . 94.7 94 9 95.0 95/1 95.2 EFFICIENCIES OF. 3" THICK JOHNS-MANVILLE 85% MAGNESIA' SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPE Pipe Size, Inches 1Va IKIK- 2 VA 33 K 4 5l'A 6 78 9 19 50 73.7% 77.0 79.5 81.3 82.8 84.7 85.6 66.8 87.5 88.1 88.5 68.9 89.5 89.9 90.1 90.4 90.6 Temperature Difference Between Steam in Pipe-and.Air Surrounding Pipe- 100 150 200 250 300 ' 350 400 450 76.3% 79.4 81.4 83.1 84 4 86.2 87.3 88.2 68.8 89.3 89.7 90.0 90.4 90.S 91.1 91.3 91.5 78.5% 81.2 83.1 84.7 65.8 87.5 88.5 89.2 89.8 90.2 90.6 90.9 91.3 91.7 91.9 92.1 92.2 80.2% 82.8 84.6 65.9 87.1 68.5 89.5 90.2 90.7 91.1 91.4 91.7 92.1 92.6 92.7 92.8 92.9 Per Cent.. Efficiencies 81.7% 84.2 85.8 83.4% 65.5 87.0 84.8% 66.7 88.1 87.0 88.0 89.3 88.2 89.1 90.2 89.2 699 91.1 90.2 99.9 91.4 91.0 91.7 92.1 91.8 92.4 92.8 91.7 92.1 92.3 92.4 92.8 93.0 93.1 93.4 93.6 92.7 93.1 93.2 93.3 93.6 93.7 93.9 9.l 94.3 93.3 93.4 93.9 94.0 94.4 94.5 86.1% 87.8 89.1 90.1 90.8 91.9 92.5 93.0 93.4 93.7 93.9 94.1 94.4 94.G 94.8 94.9 95.0 87.3% 86.9 90.0 91.0 91.7 92.6 93.1 93.7 94.0 94.2 94.4 94.6 94.9 95.1 95.2 95.3 95.4 500 88.4% 89.9 90.9 91.8 92.3 93.3 93.8 94.2 94.5 94.8 94.9 95.1 95.3 95.5 95.6 95.7 95.8 20 CRMC-003384 Johns-Manville Service to Railroads Johns-Manville Improved Asbestocel Sectional Pipe Insulation Every section of Johns-Manville Improved Asbestocel Sectional Insulation is marked with a red band on the inside of each end in the same position shown by the shaded area in the illustration. This mark distin guishes this more efficient, stronger Im proved Asbestocel from ordinary coverings. OR insulating pipes conveying steam Johns-Manville Improved Asbestocel `at medium or..low pressures or. for Sectional Pipe Insulation is furnished.; in pipes conveying hot water, . ^ 2, 3, 4, 5 and 6 ply thicknesses, each ply Johns-Manville -Improved Asbestocel is approximately thick.: It is made in: 3- . '.a cellulartype of- ihsulation ma:de up of foot sections with canvas jacket and brass- alternate layers of plain and corrugated lacquered bands,: to fit standard sizes of . asbestos felt, which form a multitude of pipe- \ air cells closed upon themselves, so that . each chamber contains dead air that can not circulate. These dead air cells are formed by the corrugations^ which run in Specifications for Johns-Manville Im proved Asbestocel Insulation will be found on page 23. two directions, longitudinally and circum Also furnished in sheet and block form ferentially. for boilers, flues and other large regular Because of its cellular structure, longi tudinal circulation of air is prevented. Improved Asbestocel is strong and dur surfaces. Sheets, 36" x 36" and blocks 6" x 36", 4" x 18", and 3" x 18", or special sizes, in thicknesses from %" to 4". able because the cells form numerous For descriptive data on this insulation arches which give the insulation strength, in sheet and block form, see page 42. and this construction accounts for its abil ity to withstand vibration and wear and See approximate weights and price list tear. on page 32. 21 CRMC-003385 Johns-Manville Service to Railroads Johns-Manville Fine Corrugated Improved Asbestocel Sectional Pipe Insulation The smaller cells give greater strength and assure increased efficiency. OR insulating train pipes or other. Johns-Manville Fine Corrugated Im Fpipes conveying steam at medium or proved Asbestocel Sectional Pipe Insula- : : low pressures dr for pipes'conveying ; tion is furnished in 4 arid 6 ply thicknesses hot water. Johns-Manville Fine ^ Corrur: in 3-foot sections with canvas jacket and -gated Improved -Asbestocel is a cellular, brass-lacquered bands ;to fit standard sizes type of: insulation made up similar to the of pipes. -.A V'A.:'v Improved Asbestocel described on page 21, except that "the corrugations are smaller. However,: there .are 50% more laminations per inch of thickness and the additional small enclosed air cells provide greater efficiency. In order to specify Johns-Manville : Fine Corrugated Improved Asbestocel, insert the words,-`Fine Corrugated" be fore the words "Improved Asbestocel" in the specification on the opposite page. Due to the greater strength of the small cells, Fine Corrugated Improved Asbes tocel is even stronger and more durable than Improved Asbestocel. As a result of smaller cells as described above, the conductivity of Fine Cor rugated Improved Asbestocel is lower than that of the regular Improved Asbestocel. Also furnished in sheet and block form for boilers, flues and other large regular surfaces. Sheets 36" x 36" and blocks 6" x 36", 4" x 18" and 3" x 18", or in special sizes, in thicknesses from y2M to 4". For descriptive data on this insulation in sheet and block form, see page 42. For prices, see price list on page 32. CRMC-003386 Johns-Manville Service to Railroads Standard Specifications for Insulating Pipes Conveying Low Pressure Steam or Hot Water with Johns-Manville Improved Asbestocel Insulation or Fine Corrugated Improved Asbestocel Insulation All pipes conveying low-pressure steam or hot water shall be insulated with Johns-Manville Improved Asbestocel Insulation of proper size and thickness. (See note "A.") All fittings and valves shall be insulated with Johns-Manville Insulating Cement, to be applied to a thickness equal to the adjoining pipe insulation. All flanges shall be insulated by method "A" or "B," depending upon whether flange insulation is to be removable and replaceable or nonreplaceable. Method "A"--Use suitable size and length of Johns-Manville- Improved Asbestocel Sectional Insulation to encircle flanges completely and overlap the adjoining pipe insulation at least two inches (2") on each side of the flange. Secure this flange covering with wire and fill space between pipe and flange insulation with JohnsManville Insulating Cement and apply a thin coat of Insulating Cement over entire outside surface of flange cover. Method "B" -- First prime flange surface with a thin coat of Johns-Manville Insulating Cement applied so as to leave a rough surface. When dry follow with successive one-half inch coats of Johns-Manville Insulating Cement until a thickness equal to that of the pipe insulation is obtained. Each coat of this cement should be allowed to dry before the next coat is applied, and each coat should have a rough surface, except the final coat, which should be trowelled down to a smooth finish. Finish of Insulation All of the above insulation,., including-fittings, paint, of the color desired.. This extra, canvas : valves and flanges, shall be 'finally finished- and ' cover to be placed over the. canvas jacket fur- .'additionally- protected with S-ourice canvas, neatly nished with the-insuiatibhi^ '(When re-ca'nvasing sewed on, over TOSimsized paper- and this canvas is not desired or considered unnecessary, see, note painted with either fireproof paint, or lead and oil ` B."j * Weatherproof Jacket 1 If piping is located out-of-doors and exposed to the weather, the additional protection of 8-ounce canvas and paint may be omitted and in its place the . insulation . shall'.be protected with a JohnsManville Asbestos Weatherproof Pipe Insulation Jacket, secured with rings formed of No. 16 copper wire wound once around the jacket and ends twisted tightly- together. These wire rings . are to be placed on 4" centers. The jacket is to lap at least 3" in all directions, and all horizontal laps are to be located on the: side of the insulation and turned downward in order to shed all water from the surface. (See note "C.") NOTE "A"--Johns-Manville maintains an engineering department at each of its branches, which will, on request, recommend proper thick ness for various pressures and temperatures. NOTE "B"--If insulation is not to be re-canvased, lacquered bands furnished with the insu lation are to be applied, at 18" intervals, on all sectional insulation. NOTE "C"--When extremely low tempera tures are encountered out-of-doors, special re commendations will be given by any Johns-Man ville Branch Engineering Department. 23 CRMC-003387 Johns-Manville Service to Railroads Johns-Manville Asbestos Fire-Felt Sectional Pipe Insulation An insulation that is partic ularly well adapted to high temperatures. OHNS - MANVILLE .Asbestos Fire- high temperatures and many other condi J Felt; . Pipe. Insulation., iscomposed of asbest o s f ibr e f el ted together an d tions; such as hot oil lines, gas engine ex haust lines, etc., where temperatures! are molded into sections of. the' required size..especially high. For such conditions Fire- This! composition assures high heat resist-, Feltis usually used for the layer of insula ing: properties .and. the -process of/manu tion against the heated Surface and Asbes- facture produces a strong resilient mater to-Sponge Felted Pipe Insulation is then ial of good insulatingvalue, because of applied outside of the Fire-Felt, This re the large number: of small air cells con sults in a combination which not only is fined in its structure. - -r.: suited to unusually high temperatures, but Johns-Manville Asbestos Fire-Felt is unaffected by vibration, expansion and contraction and many other severe condi tions common to railroad and industrial plant service. also is very efficient. Johns-Mahville Asbestos Fire-Felt is furnished in sections 3 ft., long and. in thicknesses of 1" to 3", with canvas jacket and brass lacquered bands, to fit standard sizes of pipe. See approximate weights Due to its high heat resisting properties, and price list on page 32. Johns-Manville Asbestos Fire-Felt Pipe Also furnished in sheets 24" x 36" and Insulation is particularly adapted for use blocks 6" x 36", in thicknesses from to on pipes conveying steam at unusually 4". For descriptive data, see page 43. CRMC-003388 Johns-Manville Service to Railroads Johns - Manville Asbestos Flexible Steam Pipe Insulation Details of application of Johns-Manville Asbestos Flexible Steam Pipe Insulation. /T'HIS Style of pipe covering, because , posite direction from the first. The cover:. | of its great flexibility, is admirably mg is then secured, with wire fasteners as adapted to. many uses on. and about illustrated, Or with 1716" annealed iron a locomotive, such/ as : steam pipes' to ! wire, fasteners being' located at 12 inch : boosters, air pumps, injectors, lubricators, intervals. VV- head light generator, steam heat: to regur : The advantage of this method of appli- lator, superheater damper, blower, stoker, cation is that it positively eliminates open foot warmer, grate shaker, and other joints and consequent heat losses. The steam pipes. / finished job is smooth and even over its The illustration above shows how easy entire surface as compared to the uneven it is to apply this covering. - Two layers and unsightly appearance where the ma- .of Johns-Manville Asbestos Listing are terial is wrapped one.way and lapped over, wrapped spirally, with butt joints, the All possibilities of burns are eliminated second layer being wrapped in the op- where pipes are covered with this material. Dimensions of Covering 1/16" x 1" for pipes up to and including 1" in diameter. 1/16" x 2" for pipes from 1" up to and including 2" in diameter. 1/16" x 3" for pipes from 2" up to and including 3" in diameter. This material also furnished in 1 yz" and 2l/2" widths. NOTE--Used material may be re-applied as first layer, using new material as outside layer. 25 CRMC-003389 Johns-Manville Service to Railroads Johns-Manville Asbestos Combination Spiral Pipe Insulation Details of application of Johns-Manville Asbestos Combination Spiral Pipe Insulation A l -VHIS insulation' consists , of one, layer . shaker. - Air purrip efficiency is greatly reJ_ of Johns-Manville Ceilinite Yk' thick, duced by condensation caused by heat' loss; ; cut. into v2^'' ; widths arid wrapped; from : uninsulated pipes. Moreover, eri- spirally;around-' - the pipe,-, over which gineers arid firemen are indanger of being Johns-Manville. Asbestos Listing is then . burned by coming in contact with: uniri- ; .wrapped spirally in the opposite direction, sulated hot surfaces. ; Both the Ceiliniteand the Listing are ap- The; insulation of these pipes as iUus. plied.hutt Jomt., . I desired, a jacket of above not only protects the loco eight-ounce canvas may be sewed on over motive- creW; but it also effects the sav- the Listing. ing of a considerable amount of the heat There is an enormous waste of coal otherwise lost through radiation, caused by uninsulated pipes such as: steam lines to boosters, air pumps, injectors, lubricators, headlight generator, steam heat to regulator, regulator to flexible joint at tender, superheater damper, blower, stoker, foot warmer and grate Johns-Manville Asbestos Combination Spiral Pipe Insulation is the most efficient covering for pipes where clearance conditions will not allow the application of standard thickness of molded pipe insulation. 26 CRMC-003390 Johns -Manville Service to Railroads Johns-Manville Built-up Brine and Ammonia Insulation Particularly well adapted to low temperature con ditions because of the efficiency and durability of the laminated con struction. OR maintaining the extremely low Ftemperature required in pipe lines conveying brine or ammonia or other mg open. The effective method of sealing eliminates all chance of moisture accumulating between pipe and insulation and cold liquids or gases. Johns-Manville then freezing and breaking the insulation Built-up. Brine and Ammonia Insulation open, consists of several, layers of insulating felts carefully applied around pipes to be This form of insulation should be ap- insulated. plied by Johns-Manville. Applied prices ' " ", quoted on request. On account of the high insulating qual ities of the hair felt used, .the flexibility of The conductivity, of Johns - Manville hair felt and the method of sealing, Johns-1 Brine and Ammonia Insulation is .30 Manville Built-up Brine and Ammonia In- : B.t.u., and the conductivity: vof cork is sulation is: not; only, -highly efficient as an about .35 B-t.u..per; square foot-per degree insulator,: but will withstand contraction ' temperature difference per hour per inch : and expansion without cracking or break- thickness,. . HEAT TRANSMISSION THROUGH Pipe'. Size - 2 LAYER . Per lin. ft. Per si. cf pipe of -:;e , 3.LAYER , 1 LAYER Per'lin.;ft. Per sq. ft . \Pef. lin. ft. Per sq. ft. of pipe . cf pipe of pipe of pipe ` BUILT-UP BRINE AND AMMONIA INSULATION The rates of heat . X'2 3 . -i' ui* 2 inches.-............. inches .i .... inches. .............. inches...1......... inches................ inches................ .. .086 . . .09j . . .107 . . .124 .132 . . .149 .390 .345 .310 .285 .255 .240 -074 .079 .088 .102 .109 .120 . .331 .. .288 .257 .235 .218 .193 , ,065 .070 .078 .090 .095 .104 . .295 .255 .227 .206 .190 .167 transmission given here are expressed in B. t. u. per hour, per degree temper ature difference be 2- ; inches................ 3 inches................ 3" ; inches................ 4 inches................ 41 - inches................ 5 inches................ .. .167 .. .192 . . .211 . . .228 .. .247 .. .268 .222 .210 .201 .194 .188 .184 .133 .151 .165 .176 .190 .205 .177 .165 .157 .150 .145 .141 .114 .128 .138 .148 .158 .170 .151 .140 .132 .126 .121 .117 tween fluid in the 6 inches................ . . .307 .177 .233 .134 .211 .106 pipe and air sur 7 inches................ .. .343 .172 .257 .129 .230 .102 rounding pipe, per linear foot of pipe S inches................ . . .380 p inches................ .. .415 10 inches................ . . .455 .158 .165 .162 .282 .307 .335 .125 .122 .119 .250 .273 .192 .099 .097 .111 1 and per square foot 12 inches.............. . . .528 .158 .387 .116 .311 .093 of pipe surface. 27 CRMC-003391 Johns-Manville Service to Railroads Specifications for Insulating Pipes Containing Brine and Ammonia or Other Cold Liquids or Gases with Johns- Manville Built-up Brine and Ammonia Pipe Insulation All pipe lines, including fittings and flanges it is interrupted by fittings, hangers, etc. These and other apparatus containing brine or ammonia, sealing caps shall be at least two ply in thickness or other cold liquids ot gases, shall be insulated and shall extend over the felt and under the out with Johns-Manville Built-up Brine and Ammo side sealing membrane and shall be coated with nia Insulation of the proper thickness. Where sealing compound the same as the outside mem temperatures are between 15 F. and 50 F. use brane on the pipe. two layer insulation and where temperatures are between minus 10 F. and plus 15 F. use three layer insulation. All piping and other surfaces to be insulated shall be so located that there will be uninter rupted clearance around the finished insulation of at least 3" in all directions. The insulated piping shall not be located closely adjacent to any heated surface nor located in the same pipe chase or shaft with heated pipes. FITTINGS: All fittings shall be insulated separately from the adjacent piping, the insulation being of the same thickness and shall be applied and sealed in the same manner as on the pipe. The insulation on each fitting or nest of fit tings is to be thoroughly sealed in with a sealing membrane not less than two ply thick and joined to the adjacent pipe insulation in such manner that there will be no interruption of insulation of PIPES: pipes and fittings. All surfaces to be insulated shall be thoroughly cleaned and dried before insulation is applied and the system shall not be put in operation until the insulation work is completed. . Wrap; .'pipes spirally with 'Johns - Manville Waterproof Mefobfane so that all surfaces shall HANGERS: Each hanger is to.be insulated separately, the same as the fittings, running the insulation along the rod of a Hanger for a distance not less than 6" beyond the adjacent pipe insulation. be covered with one; layer of, this .membrane. ACCUMULATORS, TANKS, ETC.: Then apply a layer of 1" .Hair Felt cut to proper Surfaces of. accumulators, tanks,: etc.,: shall be. length, so that all. longitudinal-and. abuttingjoints insulated in.die same, manner as specified above. shall, fit .closely `tqgetherahd secure -this to. the Tor. .pipe lines, except that, .extra.- thicknesses of pipe" by means,; of -a. wrapping of Two ply '.wrap insulation felts may'be 'required pn: account of ping ...tyrine. wo.upd .spirally :,q.n.- .approximately 1" lowertemperatures;1-'{Aril exposed ends1- shall be1 centers.,. Then apply additional-layers of 1" Hair sealed in. with'sealing cap's.'."v:\v ; A Felt in order to give the.tHichness specified above and apply these1 so that all longitudinal and abut FINISH GF INSULATION: ` ting joints: shall be staggered; or broken. All of. the, above insulation exposed.to. view When the proper number of plies have been shall be finished with a jacket of 8. oz. canvas, applied, wrap, spirally with; Johns-Manville sewed on over a layer of oiled paper and a layer Waterproof Membrane so that at no placeshall it of rosin-sized sheathing paper. This .canvas be less than two ply thick. Apply to the surface of jacket shall be thoroughly sized and painted with the outside waterproof membrane two coats of not less than: two coats of a first quality .lead and Johns-Manville Waterproof Sealing Compound, oil paint. allowing the first coat to set.before applying the NOTE: Johns-Manville maintains an Engin second. eering Department at each of its Branches which A sealing cap of waterproof membrane shall will, on request, recommend proper thicknesses enclose the end of the felt insulation wherever for various special conditions and temperatures. Johns-Manville Built-up Hair Felt Insulation OHNS - MANVILLE applies built-up As flow of water, duration of low tem- J hair felt insulation in required thick- peratures and other factors have much to ness and number of layers to prevent do with the thickness and method of apthe freezing of pipes conveying water and plication, each case should be referred to subjected to severe conditions. the nearest Johns-Manville Branch. 28 CRMC-003392 Johns--Manville Service to Railroads Johns-Manville Anti-Sweat Sectional Pipe Insulation Showing the broken joint construc tion which eliminates through joints. OR insulating pipes conveying cold Fwater or other cold liquids at temper atures abqve :3? degirees Fahrenheit. Johns-ManviUe Anti-Sweat Pipe Insu lation; is a combination of insulating felts that retard the flow of/heat, and moist; air to the pipes, and v Asbestos waterproofed - felts;, that protect; the--'. ihsulating,-..;.felts against the admission of .moisture.;. ; ;;r - The special broken joint construction eliminates longitudinal.and abptting.joints that, extend from- the outside of the cover ing, to the pipe in ordinary: pipe covering construction. Each section is divided into two equal thicknesses in such a manner that the outer layer can be turned; around the inner layer and slipped lengthwise to a position where both the longitudinal and circumferential joints in the outer and in ner layers are widely removed from each other. This greatly increases the efficiency and durability of the insulation. Johns - Manville Anti-Sweat is con structed of insulating felts protected by waterproofed felts, placed where they are most needed: one layer next to the pipe, two layers between the two layers of in sulation, and two layers on the outside of the insulation. . . } Anti-Sweat Insulation performs two im portant functions! It prevents the warm moist air from coming into contact with the pipe where the moisture from the air would condense and drip off. Such drip ping is unsanitary, and also is costly be cause of; damage to merchandise located below-the pipers,- V A'" 'aA." The second function of `Anti-Sweat In sulation is that by prevehting heat absorp tion by the pipes it keeps the contents of the pipes cold. Where cold, drinking water is required, or where cold water is necessary in manufacturing' processes, it must be kept cold by insulation or re cooled mechanically. It costs less to keep water cold than to re-cool it. Furnished in thicknesses of 1", IV2" and 2", in 3-foot sections with canvas jacket and brass-lacquered bands to fit standard pipe sizes. Not furnished in sheet and block form. See approximate weight and price list on page 32. 29 CRMC-003393 Johns-Manville Service to Railroads Heat Transmission through Johns-Manville Anti-Sweat Pipe Insulation Rates of heat transmission are given in B. t, u. per hour per degree temperature difference per linear foot and per sq. foot of pipe surface Pipe Size Vi .............................................. K".......................................................... l" ............................................ 1VA" . 154".............................................. 2" ............................................... 2^".............................................. 3" .............................................. 3H>".............................................. 4" ............................................ Per LirFt. .212 .245 .285 .374 .443 .518 .511 .685 .757 Thick Per Sq. Ft. .963 .891 .830 .777 .751 .713 .688 .666 .655 .643 RATES OF HEAT TRANSMISSION 3A" Thick Per Per Lin. Ft. Ft. .185 .212 .243 .284 .312 .367 .841 .770 .706 .653 .627 .591 .425 .497 .553 .611 .564 .542 .528 .518 1" Thick Per Per Lin. Ft. Ft. .167 .189 .215 .249 .272 .318 .758 .687 .625 .572 .546 .512 .364 .423 .484 .462 .468 .515 .447 .437 i'.;" Thick Per Per Lin. Sq. Ft. Ft. .143 .160 .180 .642 .581 .523 .205 .223 .257 .473 .448 .413 .292 .337 .388 .367 .359 .404 .353 .343 2" Thick Per Per Lin. Sq. Ft. Ft. .128 .142 .158 .581 .515 .460 .194 .221 .249 .284 .311 .338 .389 .356 .331 .310 .297 .287 Standard Specifications for Insulating Pipes Containing Cold Water All cold-water mains, risers and branches, shall, Membrane, wound on spirally and coated with be.insulated:with Johns-Manvilie .Anti-Sweat In- Johns-Manville Waterproof Sealing Compound. : sulatiori 1" thick i(for unusually severe conditions, All pipe and fitting insulation exposed to view -use general . recommendations given ; below);:- ap- ; . shall : be enclosed , in an; extra jacket of- 8-ounce : plied in two layers with all Joints broken, tightly canvas, applied over a- lining of heavy rosinrsized drawn together and stapled in; place: . All joints, paper and sewed , in. place, seams to be located . shall be-sealed by -means.of .Johns-Manville Mois- where least visible. T . ture-Resisting Cement applied \to the edges of the Where the lines are exposed to the weather this insulation at the:joints, before They: are drawn to canvas jacket may be omitted, and in its place the gether. All fittings .shall, be. insulated, with Hair insulation shall .be ^protected with, a layer, :of Felt of the same thickness as the adjacent pipe Johns-Manville Asbestos Weatherproof Pipe In insulation. This material'-shaH be cut' to fit The. sulation Jacket secured with rings of No. 16 gauge `fitting and secured in place with close wrapping copper wire, applied on 4" centers. The jacket of heavy jute twine. This insulation on the fit shall lap at least 3" in all directions and all hori tings shall be thoroughly sealed by rneanS'of: a zontal laps are to look, downward, in order to double wrapping of Johns-Manville Waterproof shed all water from the .surface. General Recommendations The above specification applies to insulation to prevent sweating under normal conditions, i. e., where temperature of water is over 50 degrees F., air temperature is less than 100 degrees F., and the humidity is not over 75%. To maintain water temperature between 32 degrees and 50 degrees when room temperature is less than 100 degrees F. and humidity of air is not over 75%, use 1J4" thick Anti-Sweat Pipe Insulation. If humidity is between 75% and 80%, air tem perature not over 100 degrees F. and water tem perature is not lower than 50 degrees, 1*4" thick Anti-Sweat Pipe Insulation should be used. For more severe conditions, consult JohnsManville Engineering Department. 30 CRMC-003394 Johns-Manville Service to Railroads Johns-Manville Zero Sectional Pipe Insulation The structure of Johns-Manville Zero Sectional Pipe Insulation adapts it exceptionally well to its special service. OHNS-MANVILLE Zero Sectional where temperatures are moderate rather J Cold Water Pipe Insulation is con than extreme or where the length of time structed of a layer of 1" hair felt sur that the surrounding air would be below rounded by several layers of wool felt andfreezing-point is short, . - with a layer of saturated wool felt inside Where pipes run out of doors and are the hair felt.. . This'prevents the hair .felt subjected to severe conditions or extreme fromi coming' in direct, contact .with the. temperatures, Jbhns-Marivilie Built-up- : pipe-.; - Hair Felt of: suitable thickness should be Hair felt, one of. the-best known non applied. (See page 28;) I! conductors . of heat;, greatly- retards the flow of heat frbm.the; water iii the pipe to Johns-Manville Zero Sectional Pipe In vthe cold surrounding air, and the'.wool felt sulation is: furnished ill one thickness only jacket and the inner layer of saturated felt . (approximately '1%") in 3-foot 'sections provide protection fbr the hair felt lining. : with canvas jacket ahd brass-lacquered This material : is designed 'and- con- bands, to fit standard-pipe sizes.. . . structed for insulating cold water pipes r 1 Not furnished in sheet and block form. , that are located where there is a likelihood .. See approximate weight and price list on of the water in the pipes freezing but page 32. ' Johns-Manville Wool Felt Sectional Pipe Insulation N inexpensive insulation for cold A water pipes. Made of laminations of wool felt in sections 3 ft. long, in three styles: "Standard"--1" thick, with an inner lining of one layer of asbestos paper. "Champion" or "Express"--thick; same construction as "Standard/' "Aqua" or " C-B "--thick; same construction as "Standard". Not furnished in sheet or block form. See next page for approximate weights and list prices. 31 CRMC-003395 Johns-Manville Service to Railroads Approximate Weights of Johns-Manville Sectional Pipe Insulations (WEIGHTS GIVEN ARE POUNDS PER STANDARD 3-FOOT SECTION) Kind of Covering Thick ness 3 1" i.'r 1 W 2' 2 Pipe Sues 3" 3 2" 4" 4**2** S" 6" 7" 8" 9" 10" 12" - 85 Magnesia'................. - Std. 1 0* 3' Std. 1 2" 4.35 4.70 5.26 6.00 6.42 7.38 8.31 9.52 10.60 11.60 12.50 13.80 15.70 17.70 19.70 21.70 23.80 27.80 8.95 9.50 10.40 11.40 12.00 13.30 14.70 16.50 17.90 19.40 20.80 22.70 25.60 28.30 31.00 34.00 37.20 43.00 13.00 13.60 14.80 16.20 17.00 18.80 20.70 23.10 25.20 27.10 29.00 31.50 35.20 39.10 43.00 47.50 51.30 59.20 25.40 26.50 28.20 29.70 31.60 34.30 37.20 41.00 43.80 46.70 49.70 53.70 59.30 65.20 70.80 76.80 83.50 95.50 1.62 1.85 2.02 2.39 2.74 3.77 4.30 5.00 5.57 6.82 7.42 8.05 9.35 11.90 13.20 14.50 16.10 23.00 3.77 4.12 4.59 5.10 5.52 6.27 7.16 8.10 8.88 9.70 10.50 11.40 13.10 14.70 16.30 18.00 19.80 23.00 6.11 6.75 7.30 7.89 8.40 9.42 10.60 11.90 12.90 14.00 15.20 16.40 18.60 20.80 23.00 25.10 27.50 31.60 -i * - Impr-oved Asbes- tocel. * * -- Champion Wool Felt. . .. Zero................... Std. Std. 1 >" 2" 3' 2 ply 1" 1 v.* 1" .Std. 4.86 5.31 5.80 6.42 7.23 g.82 10.90 12.30 13.40 16.40 17.60 19.00 21.50 27.30 29.90 32.60 35.70 50.70 12.40 13.20 14.00 15.20 16.00 17.40 19.10 21.10 22.60 24.20 25.90 4.80 5.06 5.35 6.00 6.40 7.08 7.88 8.80 9.53 10.30 11.10 12.00 13.60 15.20 16.80 18.20 19.90 23.00 9.70 10.10 10.60 11.40 12.00 12.90 14.00 15.40 16.40 17.50 18.50 19.80 22.00 24.20 26.30 28.40 30.70 35.00 13.00 13.60 14.30 15.60 16.40 17.80 19.30 21.30 22.80 24.40 26.00 27.80 31.10 34.30 37.50 40.70 44.20 50.60 23.00 23.80 24.90 27.00 28.20 30.40 32.80 35.90 38.40 40.80 43.40 46.10 51.30 56.20 61.00 66.10 71.40 81.40 .90 1.04 1.18 1.37 1.49 1.74 2.02 2.37 2.64 2.92 3.19 3.48 4.05 4.60 5.14 5.68 6.26 7.34 1.27 1.42 1.60 1.86 2.01 2.37 2.71 3.15 3.50 3.87 4.20 4.60 5.37 6.04 6.75 7.47 8.25 9.65 2.00 2.19 2.40 2.69 2.90 3.30 3.74 4.25 4.67 5.09 5.54 6.00 6.89 7.72 8.56 9.41 10.35 12.00 2.46 2.67 2.90 3.21 3.44 3.90 4.35 4.95 5.40 5.87 6.33 6.85 7.87 8.80 9.7S 10.67 11.70 13.60 3.10 3.32 3.60 4.00 4.30 4.83 5.40 6.10 6.65 7.20 7.75 8.38 9.60 10.70 11.80 13.00 14.20 16.45 J .Jj 3.70 4.07 4.60 4.98 5.70 6.55 7.50 8.30 9.10 9.87 10.75 12.47 14.00 15.60 17.25 19.00 22.15 4.10 4.50 5.00 5.60 6.10 7.00 7.93 9.12 10.07 11.00 11.95 13.00 15.05 16.93 18.85 20.70 22.80 26.60 7.90 8.40 9.07 9.95 10.58 11.80 13.10 14.70 16.00 17.30.18.60 20.00 22.80 25.27 27.95 30.60 33.40 38.60 1.40 1.60 1.82 2.08 2.28 2.70 3.15 3.60 4.00 4.50 2.35 2.60 2.90 3.23 3.50 4.10 4.70 5.30 5.90 6.501 3.10 3.63 4,. 20 4.75 5.30 6.40 7.50 8.54 9.63`10.70 4.00 4.43 4.88 5.30 5.72 6.67 7.60 8.50 9.40 10.30 List Prices per Linear Foot for Johns-Manville Sectional Pipe Insulation v> ."A (READ REMARKS BELOW TABULATION) Thickness. : I V" 1"' 1 `r 1 ' Inside Diameter of Pipe ' : ' . > ' Outside Diameter of Pipe :-2 2" 3": -3 Y *- 4" 4U' 5V I-; 1 7 " i-s-". . 5"- 10 " 12 " *14" 16" 18" 20". 24" 30" S . ' iS: . i$- 5': S':" $ : ;S'-' -j$ s is.1'... $ S- $ - $ $ $ 'S : s- .22' .241 .'27 :30 -.33- -.361 40 .4.5 .50 6C .65 ' .70 80-11:00 1.10 l',20 1.30 1.85 2:10 2.35 2.60 7 85 3 30 4.00 1 ' i?-Thick:.r.. .v..\ .46 .49.] 5? .5.6 :60' ;64`l 70 .76 .82 88 1 .941.001 10 1.20.1/35 1.50 1.65 1.85 2.10 2.35 2.60 2!85 3.30 4:00 2 " Thick ........ ./d :80; .85 -.90 :95 1.00 1.05 1.15 i.25 1:35 1.451.35,1 70' r.85';2.00 2.20;2.40 2.70 -3.00 3.30 3.60 4.0U 4.60 5:50 "DoubleStandard " -1 Thick............. .65 .70; .75 .80 Joints.................... i.20 1.35 1.40 . 1.45 1 .85! .9OM.O0 1.10 ! 1' 1155 1.65'. 1 ,0 1.90 l:20 l;4C 2.05 2;20 1 - 1 '< !... 1.50 1.601.80 2.2; 2:50 2:70 2.90 4.10 1 r 1 v L."' 2.35 2.50 2 70 290 3.15 3.40 3.65 4.10 4.60 5.10 5:60 6.00 7.00 8.40 , 4.60 5.10 5.60 6.00 7.00 8.40 Inside Pipe Diameter J L" I'M `A ,, " 2 " ' 2 3" 3 : 4" 4*2* , 3 6" . ,7" 8" - Q,, 10": Flange Covers . . . S .30- .36 .48 .54 .50 -.30 .3 3 .48 ..54 .50 $ S .30 I .30 .36 .36 .48 ! .48 .54 1 .54 .50 .50 $. .30 .36 .48 .54 .50 S 36 42 54 60 60 $ 42 48 60 78 70 S .48 .54 .70 .96 .80 S .54 .60 .80 1.20 .90 5 . .60' ./3 .95 1.50 1.00 5 .72 : ,.9t l.tc 1.85 1.30 $ 90 1 20 1.50: 2 25 1 60 i 1.30 1.60 2.00 2.80 1.90 $. 1:80 2.20 2.80 3.60 2.20 $ 2.40 3.00 3.60 4.40 .50 s 3.00 3.80 4.40 5.30 2.90 S ' 3.60 4.60 , .20 6.20 3.30 *85% Magnesia is made in Standard (approx. 1"), ll/2", 2", Double Standard Thick and 3" (broken joint) thicknesses. For pipe sizes from and including 14" in diameter it is furnished in segmental form. ** Applies only to 85% Magnesia. These pipe insulations are supplied in sections three feet long, canvassed and with brass-lacquered bands. Asbesto-Sponge Felted Insulation is made in thick nesses from Yi" to 4"; thicknesses 1'' and under, use list prices for Standard Thick. Improved Asbestocel made in 2, 3, 4, 5 and 6 ply. Use Standard Thick list prices for all thicknesses. Fine Corrugated Improved Asbestocel Insulation is made in 4 ply and 6 ply. Use Standard Thick list prices. Zero Insulation is made in one thickness only, ap proximately 1*4". Use Standard Thick list prices. Anti-Sweat Insulation is made in 33", 1". 1/4" and 2" thicknesses; use Standard Thick list prices for all thicknesses under 1". 32 CRMC-003396 Johns-Manville Service to Railroads The Johns-Manville Underground System of Insulation for Steam and Hot Water Pipes HE Johns-Manville Underground T System of Insulation provides a per manent, efficient and economical of installation of them by Johns-Manville engineers. The average efficiency of the Johns- means of placing underground and insMuanville System is at least 90% when in lating pipes conveying steam or hot water. stalled according to our specifications and The system comprises not only the in by us or under our supervision. This high tegral parts shown on page 35, but the efficiency is maintained for a long period proper selection and arrangement of these of time on account of the character of the parts and the installation or supervision materials used in the construction. Insulating Material Used For the base of the insulating material lated, it completely fills the space inside of which surrounds the pipes we chose asbes the protecting and containing parts of the tos -- a natural rock, unchanged by high system. It is extremely resilient and temperatures,' ' immune to: moisture;' spongy, so that there is little tendency for wear; rot and rust. To provide for maxi it to settle... mum1 insulating. efficiency we combined.; The fact that Johns-Manville Asbesto- specially selected fibres of this .asbestos; rock with other'material of a. sponge-like r nature .which, y^hen prdpdrly; mixed with asbestos fibre,; forms the most efficieiit.and, most durable insulating material for., un-, derground work-^Johns-Manville Asbes- to-Sponge Filling. " % Sponge Filling maintains its high initial ' heat insulating1 efficiency . year ;after' year without depreciation makes it the most economical insulation possible to use for this work. Its saving of heat does not diminish as- time goes on, and it is the "cheapest-per-year" of all underground The. high and lasting heat insulating insulations.. UV'V'1 efficiency of Johns-Manville Asbesto- Sponge Filling is due to the many "dead The correct amount and thickness of air" spaces and cells which it confines, and this insulation has been accurately deter to its base of indestructible asbestos fibre. mined for various conditions by the most When packed around the pipe to: be insu- rigid tests. Supporting Roll Frame The Johns-Manville Supporting Roll Frame has been designed to provide sup port for the pipes and to insure that they may move freely when expanding and contracting. This roll frame, anchored in a concrete base, supports the entire weight of the pipes and their contents and prevents any load from being carried by the containing and protecting member. The movements of the pipes due to expansion and con traction thus produce no effect on the sys- 33 CRMC-003397 Johns-Manville Service to Railroads tem. This method of support is sufficient to signed and made according to the number bear any weight required of it in service, and combination of pipes that may be Johns - Manville Roll Frames are de- contained in the conduit. Supporting Sections The supporting section of the system is concrete base in which the roll frame is a most important part as it completely embedded and also acts as a connecting covers and encloses the roll frame and the link between the containing sections. Containing Sections The supporting sections are connected by containing sections, which complete the continuous stone protective member which surrounds the entire system and acts as a container for the Asbesto-Sponge Filling. The sections are split diagonally, so that the lateral joints will shed water better than if the cut of the joint were straight, and each half of every section is numbered so that in the installation of the system mates.of each section will always be placed together. Underdrain -. Provision: ' is ,made to .prevent 'water. :frpm accumulating around the system and to drain or carry.it away by the use of an ;imderdrain of small .rtile'J0|pe-viaid;|vw.ith^ .open joints ;and ,storie, which is carried Up and: around the system to a-poirit above the lateral joints! The design and proper location of an chors, anchor-pits, manholes and manhole covers are details carefully worked out by our engineers according to conditions. Manholes or pits are used: as required by the nature of the installation. In a small installation there is no call for a large manhole, as the pipes may be an chored or a branch may be taken off in a small pit (commonly called a blind pit) to which no ready means of access is. nec essary. " ,< Wherever there may be : valves, , expan-: sion joints,; flanged joints; or other fea tures which:itsary to get at occasionally, and which cannot be placed in a building into which the system runs, a manhole with a remov able but water-tight cover should be em ployed. Where any part of the system termin ates, whether at a building, anchor-pit or manhole, the ends are sealed in by spec ially designed shutters. See pages 37 and 38 for detailed specifi cations. 34 CRMC-003398 Johns-Manville Sendee to Railroads Integral Parts of the Johns-Manville Underground System of Insulation - --------- -- SECTION SHOWINGiMETHQD- OF CONSTRUCTION- AT - . - MANHOLE' ! 35 CRMC-003399 Johns-Manville Service to Railroads The Johns-Manville Underground System of Insulation in Course of Installation Sections being split before being pieced intrench a* Pennsylvania Reform Schoo^Moiganze, Pa 36 CRMC-003400 Johns-Manville Service to Railroads Specifications for Steam and Hot Water Pipes to Be Installed Underground 1. All steam lines and returns and all hot water lines that run outside of power plant or buildings shall, as indicated, be run underground and insulated by the Johns-Manville System of Underground Insulation. 2. This system shall consist of: (a) Roll frames and rolls for the support of piping. (b) Supporting sections for the enclosure and support of the roll frames. (c) Straight sections and unions for the connections between supporting sec tions and buildings or pits. (d) Johns-Manville Asbesto-Sponge Fill ing for the insulation of the pipes. (e) Underdrain for drainage of system. (f) Broken stone or gravel of suitable size for surrounding lower half of system. (g) Shutters to seal the ends of the system . where it terminates, in buildings,.., manholes, or pits.. '. , . -r (h) Manholes and .-anchor pits to be pro- . vided as indicated to allow for con- ; trol of expansion and contraction -or ; ; , for changes in direction or elevation pf;the. system:-.: .Ur.v: J.U-V-/ v!..;.-- (i) Suitable covers for manholes. The system complete and when installed shall provide for the support of pipe or pipes at proper intervals, so that neither the weight of the pipe nor the movement of same due to expansion or contraction will cause strain or stress to come on the tile containing members of the system. The containing members, (b) and (c), para graph 2, shall be of a size that will provide not less than three inches of space for insulation be tween the top of pipe or pipes and the nearest point of the containing member, and between the side of pipe or pipes and nearest point of con taining member. The space referred to, to be measured between the outside surface of the pipe and inside surface of the containing member. The supporting sections shall be so designed and made as to provide a suitable concrete base extending from the broken stone or gravel bed ding under the containing members up through the special opening to the interior of the contain ing members, and the .roll frames, are to be. set into these bases when they are built. The entire space in the containing member-not occupied by pipe, rolls and, roll frames to be filled with A'sbesto-Sponge Filling' a proper combina tion of asbestos and suitable raaterial of a spongy nature. t-'.: Material 3. 'All..material,,iisted.vun;de.r;:it:ems,:,(a:) to (e) 4. Material listed.under items (g) and (h), - inclusive-,;`;':and./item ;:;(i).;4paragfaph^2,;.to be .fur- paragraph.. 2, to be ..furnished'':by> party ' agreed . nished by-johnsrMari.yiiie Inc,. upon arid stipulated.hereafter. Supervision of Installation . 5. Johns-Manville Inc. shall -furnish a representative capable of supervising the installation of the system -above: described and all. work done by the labor required to install the system is subject to the approval of the Johns-Manville representative, whether said labor be furnished by Johns-Manville. Inc. or otherwise, as stipulated hereafter. 6. AU labor and tools required for the digging of trenches for the system, the handling of broken stone or gravel,: the back-filling of trenches after the insulation of piping has been cbtnpleted, and for the actual installation of the various parts of the system, shall be furnished by the party or parties stipulated hereafter, NOTE TO ARCHITECT OR ENGINEER SPECIFYING When possible it is advisable to consult with the engineering department at the nearest Johns-Manville branch regarding the selection of party or parties referred to in paragraphs 4, 5 and 6, as local con ditions, the size of the installation, and the location of same have much to do with the selection of parties best qualified to handle various parts of the installation. Whenever possible Johns - Manville 37 CRMC-003401 Johns-Manville Service to Railroads recommends and desires to furnish its own men as well as a superintendent to install all items (a) to (g) inclusive, paragraph 2. There may be exceptions such as the in stallations of systems at some distant or out of the way place or at some institution that desires to furnish its own labor. In all cases, however, the installation of the sys tem must be under the supervision of Johns-ManvilleInc. Levels and Lines 7. Unless otherwise agreed, levels and lines for laying the system to true and proper grade shall be furnished by the engineer or owner. The batter boards indicating such lines and levels shall be furnished and set at intervals of about 33 feet by the engineer or owner. The Installing or Laying of Pipes to Be Insulated 8. It is to be understood by the steam-fitter or In case any leaks or defects develop when pipe contractor who is to furnish and install the pip is subjected to test, such repairs or replacements ing to be insulated by the Johns-Manville Sys as are satisfactory to Johns-Manville Inc. are tem, that no flanges, companion flanges or to be made before the system is insulated and the flanged fittings are to be used where pipe is sur top halves applied. rounded by the underground insulation, and that all such connections are to be made with extraheavy screw couplings or welded connections ac. cording to heating or steam-piping specifications covering that work. All pipes to be anchored with suitable anchor ing devices furnished by the steam-fitter and pro per provision, made for expansion as shown in plans and specifications. Where pipes are run through walls or through ; Furthermore, the piping shall be placed and shutters--item (g) paragraph 2--where the sysconnected on rolls; as they are provided by party installing same, as soon as said rolls have been - -tem or part of- same, begins and terminates, the installed and are-ready for the pipe. And before .steam-fitter shall furnish and place around pipe, the Asbesto-Sponge Filling and top halves ofi the> . sleeves made of the next size of pipe that may be -.system -are-' in, place,: the steam-fitter ;or con .. . slipped over pipe to be insulated, and these sleeves tractor placing the piping shall subject the-pipe shall be of, such a length as to extend entirely placed to a hydrostatic; test ib.utually agreed up through wall or shutter and from two to four on by the: owner and Johns-Manville .Inc. inches beyond;each side of wall or shutter. NOTE TO ARCHITECT; OR-ENGINEER SPECIFYING Next and finally, stipulate party or parties to provide labor and materials mentioned in paragraphs 4, 5 and 6. 38 CRMC-003402 Johns-Manville Service to Railroads Johns-Manville Asbesto-Sponge Felted Sheets and Blocks Illustration shows laminated construction of this material. OR efficiently insulating any surface Eto which these sheets may be fitted, providing the temperature of: the sur- withstand vibration, - shocks, and the rough usage of shipment and general handling without, crumbling, pulverizing face to which the material is applied, does- . or the loss of value or, efficiency , so com- not exceed .7509 Fahrenheit. . ^ mon to moulded and similar insulations, : Johns-Manville Asbesto-Sponge Felted The? can be removed and replaced with- Sheets and Blocks are constructed by ut injury. '.,AA.' building up to the required size and thick- ': Asbesto-Sponge Felted Sheets and ness a number of sheets ,of Asbesto- Blocks are flexible, and conform to curved Sponge Felt, of the same kind as used in surfaces of boilers, tanks, etcJ, without the the manufacture of Asbesto-Sponge Felt- necessity of moulding specially for each ed Pipe Insulation. . - . ' required radius which is necessary in the The remarkable efficiency of this mate- case of moulded insulation. rial is due,; to the enormous number of minute confined dead air spaces in the felt itself as well as the dead air spaces formed between the layers of the felt as built up to produce the finished product. The relatively large sizes in which Asbesto-Sponge Felted Sheets are fur nished assure fewer joints and less time and labor for application than in the case of materials which are furnished only in The advantages of Asbesto-Sponge block form. Felted Insulation lie in its high efficiency and the fact that it retains this high effi ciency throughout its long life. Furnished in sheets 24" x 36" and blocks 6" x 36", from to 4" in thickness. For efficiencies of Johns-Manville As On account of the materials used and besto-Sponge Felted Sheets and Blocks, the manner of constructing Asbesto- see page 48. For approximate weights Sponge Felted Sheets and Blocks they and list prices, see page 49. 39 CRMC-003403 Johns-Manville Service to Railroads Johns-Manville 859 Magnesia Blocks For insulating flat, curved and irregular surfaces. OHNS -MANVILLE 85% Magnesia that can be broken in order to apply it to Blocks are composed of 85% carbonate the irregularities. of magnesia and 15% asbestos fibre, Furnished in blocks 3" x 18" and 6" x molded, into block form. This material is 36", from to in thickness, particularly; adapted to conditions where For efficiencies of Johns-Manville 85% it is necessary to use material- that is light Magnesia Blocks,' see page 48. .` - in weight, or where surfaces are. so irregu- See approximate weights and price list lar, that : it is necessary to use a material- on page 49. - - j Johns-Manville 85 '/ Magnesia Locomotive Boiler and Air Pump Lagging WENTY-FIVE to thirty years ago fit the surface of the boiler, in accordance T wood- was: the standard lagging for : with blueprints submitted by the railroads locomotive boilers in this country, or builders, giving correct dimensions. while at the present time practically all boilers are lagged with 85% Magnesia, which combines the high non-conducting qualities of carbonate of magnesia and The magnesia lagging used in boiler in sulation can readily be applied in blocks ranging in length from 24 inches to 40 inches and 6 inches wide. In order to ob tain a uniform outline it is the common asbestos in a light, highly efficient insula practice to taper the blocks to provide for tion. This can be furnished in various the thickness of the boiler sheets where thicknesses, curved, straight or tapered to they lap at the seams. 40 CRMC-003404 Johns -Manville Service to Railroads It is highly im blocks should be portant to insulate used. The blocks boilers, domes, cyl are applied by wir inders, and large ing them fast and surfaces because if finishing with a not insulated these coat of Johns-Man- surfaces will radiate ville Asbestos Insu a great deal of heat lating Cement ap and consequently plied in two layers waste fuel. These over hexagonal surfaces are suc Showing lagging in place. wire reinforcement. cessfully insulated with 85% Magnesia For pressures of 100 lbs. and upward 2" Blocks which are easily applied, as shown below, remain permanently in place and are extremely light in weight. Insulating these surfaces with JohnsManville 85% Magnesia Blocks will give much better.results than if insulating ce ment is used because the 85% Magnesia is a much more efficient: insulation. 85% Magnesia Blocks applied and finished as described above should be used. For pressures below 100 lbs. use 1%" 85% Magnesia Blocks applied and finished as described above. We also furnish complete sets of 85% Magnesia Lagging for all types and sizes of air pumps. . For list-prices see, page 49. Prices for , For . complete insulation1 to 2" air pump lagging-quoted on application. Showing method of applying Johns-ManviUe . 85*^ :Magnesia Locomotive Boiler Lagging. Method of Application. Wires are passed around the boiler at about 4 inches from the ends of every course of blocks. Special T-hooks for fastening engage the wires, and the blocks are slipped under the hooks, which hold them firmly in place. This method of fastening permits the removal, when necessary, of a single block without dis turbing the others. When all blocks are laid, a planished jacket is passed around the lagging and fastened on, thus closing the joints and binding the blocks securely together. Blocks may be cut with saw, knife, or chisel. 41 CRMC-003405 Johns-Manville Service to Railroads Johns-Manville Improved Asbestocel Sheets and Blocks A particularly efficient sheet and block insulation that is light in weight and durable. OR insulating medium or low pres F sure boilers, feed-water heaters, dry rooms and other surfaces whose tem peratures are not extreme. Johns - Manville Improved Asbestocel Sheets and Blocks are made of plain and corrugated asbestos felts, several of which are built up one upon another until proper thickness of cellular structure is obtained. The main corrugations are crossed at right angles by other corrugations at in tervals of about 1%", forming numerous enclosed dead air cells. This construction not only makes the sheet strong and dur able, but also eliminates circulation of air through the corrugations. Asbestos Felt offers high resistance to heat and in cellular form provides parti cularly good insulation. Furnished in standard sheets, coarse or fine corrugated* 36" x 36", or blocks 6" x 36", 3" x 18" and 4"x 18", from i/2" to 4" in thickness.. .. See approximate Weights arid price list on page 49. ;" Johns'Manville Asbestocel (In Flexible Roll Form) OHNS - MANVILLE Asbestocel in J flexible toll form is made by fastening together a plain and a corrugated as bestos sheet.. It is generally used for insulating hot air heater or furnace pipes* etc. It is applied by wrapping one or more times around the pipe to be insulated and fastened on with wire wound around it spirally. Additional fastening should be provided by wire rings placed about every 18 inches. At least two layers of Asbes tocel should be applied on warm-air fur nace pipes. To provide a neater finished appearance asbestos paper may be pasted over the sur face of the Asbestocel after it has been wired on. Furnished in rolls 3 feet wide containing approximately 250 square feet. List Price 1 Ply (about thick). . .$0.10 per sq. ft. 42 CRMC-003406 Johns-Manville Service to Railroads Johns-Manville Asbestos Fire-Felt Sheets and Blocks An asbestos material especially adapted to insulating extremely hot surfaces. OHNS-MANVILLE Fire-Felt Sheets Fire-Felt with the result that a highly J and Blocks are made; by felting and efficient combination is obtained which moulding asbestos fibre into sheet or will withstand, higher temperatures than block form. The process used in the manthose to which the more efficient.materials ufacture of Johns-Majiyjille Fire-Felt pro- may be applied direct. . . duces a heat resisting material of good in... sulating value, that is strong and resilient, and that will not readily powder or crum ble even when , applied to .surfaces that move or vibrate. Among the places where such combina tions are particularly desirable are furnace walls, oil stills and other apparatus oper ated at temperatures too severe for most other insulating materials; Johns-Manville . Fire - Felt, due. to; its strength, durability arid high heat resist ing qualities; is - particularly; adaptable to many uses where the conditions are un usually severe, such; as the lining, of breechings or flues where the tempera tures are particularly high, and the lining of boiler tube doors where considerable mechanical strength is required to with Johns-Manville Fire-Felt is furnished in standard sheets 24" x 36" and blocks 6" x 36", in thicknesses from %" to: 4". The sheets rhay be furnished curved to radius in order to fit the surface to be in sulated. This permits of using full sized sheets on curved surfaces, instead of small blocks. stand the vibration due to opening and A decided advantage in the use of Johns- closing of doors. Manville Fire-Felt in large sized sheets is Another use to which Johns-Manville that this permits of application with only Fire-Felt is especially adapted is for the a few joints, as compared with the large first layer of insulation applied on a highly number required with a material furnished heated surface where a material of high only in small blocks. This results in heat resisting properties is required. Then higher efficiency, because the elimination more efficient Johns-Manville insulating of joints eliminates a large source of heat materials, such as Asbesto-Sponge Felted, loss. 85% Magnesia, or Fine Corrugated As- See approximate weights and price list bestocel may be applied over the layer of on page 49. 43 CRMC-003407 sUfitgi^^ Johns-Martville Service to Railroads Johns -Manville Thermo Fire-Felt Sheets and Blocks n I I Exterior of sheet. Section of block showing cellular center. N improved, efficient sheet or block A for insulating!, hot blast stoves in steel -plants, -kilns, and furnaces: in be applied between a brick lining and an outside steel shell, as in the case of hot blast stoves in steel mills and other similar industrial plants^ breechings, flues, boilecronditions. Thermo Fire-Felt is an insu walls, etc, `-.T. : - lation which.w-il.l remain securely in- place t. Johns -Manville- Thermo Fire-Felt in spite of expansion and contraction of Sheets and Blocks are made by felting and the brick lining. molding: asbestos' fibre into sheets, of pro The application of Johns-Manville per size arid thickness with a:, cellular Thermo Fire-Felt in large sheets gives structure embedded in the center; of; each this material a decided advantage over sheet. The construction - of; Johns - Man- materials furnished only in small blocks, ; ville Thermo Fire-Felt :is' unique, in that because the ; use; of large sheets requires this cellular structure does not extend to only a few joints,, as compared with the the edges of- the sheet, but is completely- large number required in the case of small sealed in. Therefore, the efficiency of the blocks. Fewer joints mean higher effi material is increased because of the con ciency, because the elimination of joints fined air spaces. . , eliminates a large source of heat loss. This construction is particularly desir Johns-Manville Thermo Fire-Felt able because in addition to giving in is furnished in standard sheets 24" x 36", creased efficiency the cellular structure in thicknesses from iy2" to 4". This ma adds strength and gives the desirable pro terial may be furnished also in curved perty of resiliency, which makes Johns- sheets or sheets of special size. Manville Thermo Fire-Felt especially For efficiencies of Johns-Manville suited to conditions where expansion and Thermo Fire-Felt Sheets and Blocks see contraction are large factors. page 48. Johns-Manville Thermo Fire-Felt See approximate weights and price list is especially desirable as an insulation to on page 49. 44 CRMC-003408 Johns -Manville Service to Railroads Johns-Manville Vitro Fire-Felt Sheets and Blocks OR the insulation of hot blast mains Fand bustle pipes or particularly severe heat conditions, the use of Johns- with the exception that the embedded cel lular structure is more rigid and has greater heat-resisting qualities. Manville Vitro Fire-Felt between the shellFurnished standard in sheets 24" x 36", and fire-brick is recommended. Thermally in thicknesses from l1/^' to 4". efficient, this insulation is exceptionally May be made in curved sheets or in strong and durable. sheets of special size. Johns-Manville Vitro Fire-Felt is simi See approximate weights and price list lar in construction to Thermo Fire-Felt on page 49. Johns-Manville Asbestos Roll Fire-Felt (Plain or Indented) On account of its great flexibility, its insulating and heat esisbng : properties, :Asbestc>.S' Roll Fire-Felt is adaptable to a wide variety of uses. T*) LAIN---A soft, flexible felt of asbes- / These indentations make the sheet more tos fibre, used for a great variety of flexible so that-it can be easily bent to a / :: purposes where there is; need of an small radius., The indented construction. insulating and Leat^fesisting felLthat may. : also provides greatereonfinement of dead be folded, bent or .wrapped: around pipes air spaces when/the insulation -is wrapped and.heated surfaces. : :-; :: a.A:, or built up on surfaces to be insulated. It - It isespecially; adapted to :wrapping; around pipes which are too close to adja cent pipes, other equipment, or partitions to permit the use of sectional covering. INDENTED--Made of the same ma terial as the plain Roll Fire-Felt except is, therefore, more efficient than the plain material. Both plain and indented Fire-Felt are furnished in thicknesses of ^2."> i c"> Yi" and in rolls 3; ft. wide containing that the surface of one side is indented at approximately 100 sq. ft. See page 49 for close intervals over its entire area. approximate weights. LIST PRICES AND THICKNESSES Thickness :?" thick........................................................... thick.......................................................................... /!." thick.......................................................................... J'' thick.......................................................................... iT thick.......................................................................... List Price Per Sq. Ft. .................................................................... $0.16 .................................................................... .20 ...........................................................................26 .......................................................................... 30 .......................................................................... SO 45 CRMC-003409 Johns-Manville Service to Railroads Johns 'Manville Vitribestos Sheets and Blocks Curved sheets for lining stacks 'and-circular, ducts. Flat sheets for lining breechings, square ducts, etc. OR ..lining, smokestacks and flues, Johns-Manville Vitribestos Sheets are Ebuilding theatre curtains and for use made either flat or curved to'any radius v: : where a strong, stiffy insulating sheet . .and on account of their insulating value or block is required that will; resist teiri- are admirably adapted; to use' as a,stack;, peratures up to 80d^F;';'hf;-hV-'v:^ . ' lining. They ar4 especially adapted to: the V; lining of steel stacks on .account of their Johns-Manville Vitribestos is made of light weight, asbestos felts which have been corrugated ,' and built up to form a cellular sheet. Drawings showing arrangement of These sheets are subjected to a treatment curved steel angles that provide for the and process which vitrifies them and easy application of stack lining will be fur- makes them more resistant to moisture nished upon request, and high temperatures than other cellular sheets which have not been vitrified. Vitribestos when used as a flue lining or in fireproof construction is held in place The vitrified sheet has not, however, as and supported by bolts or steel angles, the great an insulating value as untreated application of which depends upon the type sheets and its use should, therefore, be of construction required. Full particulars confined to those places which require the and details will be furnished by any Johns- qualities referred to above. Manville branch. 46 CRMC-003410 Johns-Manville Service to Railroads Johns'Manville Asbestos Sheet Millboard OR general use where sheet or board plants where fire protection is desired. F is desired for protection against fire, Standard sheets, 40" x 40", 42" x 44", heat, acid fumes, etc. Made of as and 48" x 48". bestos fibre and suitable binders. Exten sively used for lining doors, partitions and Made in three grades: Hard, medium floors, and for a variety of heat-resisting and soft. Medium furnished unless other purposes in factories, mills and power wise specified. Prices on application. \ fastened'.: with . nails or . .........screws-- .. ... .. .. WEIGHTS OF JOHNS-MANVILLE ASBESTOS SHEET MILLBOARD Weights Thickness Per Sheet 40" x 40" Weights Per Sq. Ft. 1^9-inch........... ............. 2.4 pounds.......... .............. 3.4 ounces %-inch............ ............. 2.75 pounds.......... .............. 4 ounces Ke-inch........... .............. 5.3 ounces f6i-inch........... ............. 5 pounds.......... .............. 7.2 ounces 5^>-inch........... ............. 5.5 pounds.......... .............. 8 ounces J/g-inch........... ............. 7 pounds.......... ..............10 ounces ?3<rinch........... ............. 9 pounds.......... ..............13 ounces Jfa-mch........... ............. 10 pounds.......... ..............14.4 ounces J-^-inch........... ............... 14. pounds. ...... ......... .. .20.2 ounces ' $(6-inch........... ............... 17 pounds/. ... ......... .24.5 ounces %-inch........... ............... 20 pounds'. . ......... 28.8 ounces J^-inch........... ............... 25 pounds..... ......... 36 ounces Johns-Manville Asbestos Paper and Roll Board ... The ; uses . of Johns-Manville- Asbestos Paper are large and varied; in general* it is used as a fire retardant. : Its thinness makes it necessarily less, efficient as an in sulator than either Johns-Manville Asbes- tocel in flexible, roll form or Johns-Man ville Roll FirerFelt, and in order to obtain appreciable insulating effect, if used for that purpose, several wraps are necessary. Prices on application. ' ' Approximate Weight per 100 Square Feet ASBESTOS PAPER: Anproxiraate thicknessInches 6 pounds..................... ........................ ....................................... 015 8 pounds.......................... ............................. ....................................... 018 10 pounds........................................................... ....................................... 020 12 pounds........................................................... ....................................... 025 14 pounds........................................................... ................................ 16 pounds........................................................... ................... .028 35 pounds........................................................... ................................ ! i'o ASBESTOS ROLL BOARD: 53 pounds............................................................ ................................ 68 pounds............................................................ ................................ & % 47 /- For use when insulating material of minimum thickness is required. CRMC-003411 Johns-Manville Service to Railroads What Insulation Efficiency Means The efficiency of insulating material is ex pressed by a percentage, which is the percent of heat saved by using the insulation, as compared to what would be lost if no insulation were used and the surface left bare or uninsulated. The efficiencies of all insulations vary accord ing to the temperature difference between the surface and the surrounding air, as well as ac cording to the thickness of the insulation. Complete information regarding the use of efficiency tables, with example to illustrate will be found on page 248. For table showing the total heat lost from bare surfaces, see page 249. EFFICIENCIES OF JOHNS-MANVILLE ASBESTO-SPONGE FELTED SHEETS AND BLOCKS Thickness cf Insulation 1" .................................. l'A".................................. 2 ".................................. Z`i".................................. 3 ".................................. .......... .......... .......... .......... 50 82.90% 90.64 92.36 93.54 Temperature Difference between Hot Surface and Sui rounding Air 100 84.17 88.77 91.32 92.92 94.02 150 85.42% 89.67 92.00 93.46 94.49 200 250 300 350 Per Cent. Efficiencies 86.50% 90.44 92.61 93.96 94.91 87.50% 91.15 93.12 94.39 95.25 88.38% 91.78 93.61 94.79 95.59 89.26% 92.40 94.10 95.19 95.92 400 90.10; 92.98 94.55 95.55 96.23 450 90.92% 93.56 95.00 95.91 96.54 50Q 91.73; 94.14 95.44 96.28 96.85 EFFICIENCIES OF JOHNS-MANVILLE 85% MAGNESIA BLOCKS Thickness of Insulation 50 .......... 80.80% 2" ........................ ---------- ' 2%".................................... 91.19 ... 3 ................................ .: - 92.55' : - Temperature Difference between Hot Surface and Surrounding Air 100 150 82.36 i 83.90% 87.40 1 88.53 . 90.16 . . . 91.08 91.95 92.69' 93.22 93.83 200 250 300 350 Per Cent. Efficiencies 85.20% 89.49 91.85 93.32 94.37 86.48; 90.37 92.53 93.87 94.82 87.60% . 88.70% 91.16 91.94, 93.12 93.71 94.38 94.87 ; 95.25 95.67 400 89.64% 92.65 94.27 95.31 96.06 450 90.56% 93.32 94.80 95.73: 96.40 500 91.48% 93.97 95.31 96.14 96.75 EFFICIENCIES OF JOHNS-MANVILLE THERMO FIRE-FELT SHEETS AND BLOCKS Temperature Difference between Hot Surface and Surrounding Air Thickness of Insulation 50.. . 100 . ; iso.0., 200 = 250 .300 . . ... 350- ''400.' . 450 500 Per Cent. Efficiencies l'A". i..........i-i... 2 ............... 2SA"................. ,%.,... 3 .......... ..... 78.70%. : 80.55; ' 82.30% . 83.27,'. ' 84.64 86.00 . . 86.09 :' 87.23 - 88.37 . 88.14: . 89.08 90.02. : 83.80% 87.18 . 89.39 90.92 85:10% 88:20 90.27 91.66 86.27% 89.14 91.03 92.33 87.42% . 90.08 91.79 93;00 ' 86.48% 69.50% 90.92 91.73 , 92.48 . 93.17 - 93.57 . .. 94.17. - 90.60%' 92.51 93.82 94.72 . The above efficiencies'.are. b'ased.on the :a'pplicatiori'df sheets to flat surfaces. .. They. are,.approximately, correct however, for Curved', surfaces, curved ' to - taTge radius, such" as' boiler drums, tank's, etc.- What is the efficiency of Asbesto-Sponge Felted In sulation .3" thick to be applied, bn a surface at a tem perature-of 450 F. in a room where temperature is 70 F.? The temperature difference is 450 F.---70 F.=380. Refer to table of Efficiencies for Asbesto-Sponge Felted Insulation (on this page). Efficiency for 400 F. temperature difference is........... 96.23% 350 F. temperature difference is........... 95.92% Difference for 50.... 0.31% If difference for 50 F. is .31% then for 1, difference is .31% + 50 = .006%. The difference (380) is 30 more than 350, so 30X.006%--.18%, which added to 95.92%*=96.1%; the required efficiency. To find exactly how much heat is saved by applying this insulation, proceed as follows: Refer to table giving total heat loss in B.t.u. per square foot of bare surface (page 249). Under temperature difference of 400, you find loss is 1614.0 B.t.u. per hour, and under 350 difference loss is 1269.4. The difference in loss for the 50 difference is 1614.0--1269.4=344.6 B.t.u., and for one degree dif ference it is 344.6^-50=6.89 B.t.u. The difference you have (380) is 30 more than 350, so 30X6.89=206.7 B.t.u., which added to 1269.4=1476.1 B.t.u., the required total heat loss from one square foot of bare surface per hour. Having obtained the loss for bare surface, the saving effected by the 3" Asbesto-Sponge Felted Insulation is obtained by multiplying the total loss, 1476.1 B.t.u., by the efficiency of the insulation previously found (96.1%) or 1418.4 B.t.u. saved per square foot per hour. This result may be compared with the quantities of heat saved by other forms or thicknesses of insulation, which quantities may be obtained in similar manner to the above. 48 CRMC-003412 ii Johns"Manville Service to Railroads Johns-Manville Sheet and Block Insulation Approximate Weights and Standard Sizes Material Asbesto-Sponge Felted Sheets and Blocks Standard Sizes Lbs. per Thickness Sq. Ft. x 36", Per inch of thickness--3.5 85% Magnesia Blocks................................................ ' x 36", Per inch of thickness--1.4 Vitribestos Sheets ..................................................... ........... 36"x 72" ........... ............... /" .88 i 36"x 72" ........... ............... 3Z" 1.3 36"x 72" ........... ............. 1" 1.8 36"x 72" ......... ............... w 2.2 36"x 72" ......... ............... 1/2 2.6 36"x 72" ........... ............... 2" 3.5 36"x 72" ........... ................ 2Vz" 4.4 36"x 72" ........... ............... 3" 5.3 Thermo Fire-Felt Sheets..:........ .. Vitro Fire-Felt Sheets......... . J...:.. . . . . 24" x 36" and 6" x 36"......... ............. 24" x 36" and 6" x 36"......... ............... 24" x 36" and 6" x 36"......... ............. 24" x 36" and 6" x 36" ......... ............... 24" x 36" and 6" x 36" ......... ............... 24" x 36" and 6" x 36"......... ........... . 24" x 36" and 6" x 36"......... ........... 24." x 36" and 6" x 36" .... ......... */" 3Z" 1" 1/" 1/" 2" 2/" 3" V 24"X 36" ......... 24"x 36" ......... ............. 1/" .......... 2" . . 24" x 36" .......... : 24" x 36" .......... 1/" 2",-.. 1.2 1.8 2.3 2.9 3.5 4.4 6.2 7.0 3.5 4.5 3.8 4.8 Improved Asbestocel Sheets and Blocks 4-Ply to the inch;;.. .>..;. .'..:.;. . .... .>36" x 36", 3" x 18 ", 4" x 18"-, 6" x 36", 1" 1.0 6-Ply to the inch.. ;.. i V . .. .... .36" x 36", 3" x 18 ", 4" x 18", 6" x 36", 1"'' ' 1.3 Asbestocel-Flexible Roll Form. , Asbestos Roll Fire-Felt.. ....^ * '. . *1 .. i .. .. ... . i . 36" wide in rolls of about 250 sq. ft: 1-ply . 36" " " .``Moo '``'.MM sV?-". 36" " " " " " iob 36" " " " " " 100 tt .W Jl tt. 36" " " " " 100 36" " " " " " 100 /" Vs" ,25' ; *'' -38 .59 .75: 1.2 1.5 List Prices Asbesto-Sponge Felted, 85<~c. Magnesia, Vitribestas, Improved Asbestocel, Fire-Felt, Thermo Fire-Felt and Vitro Fire-Felt Thickness Inches Price per Sq. Ft. %" ............. ........... $ .27 f-q" ................................ 27 Vs" ............. ................... 30 r ............. ................. 30 iy6" ............. ................... 34 -w............. ................. 38 Thickness Inches Price per Sq. Ft. 13/" ........... ................... 42 1/" ........... ................... 45 is/" ........... ................... 49 1/" ........... .................... 53 17/" ............. ................... 57 2" ........... ................... 60 Thickness Inches Price per Sq. Ft. 2TZ" 2lA" 2V&" 2lA" 25/" 23/" $ 64 68 ... .. 72 75 79 ............. ................... 83 Inches 4" V/," 31/" 4" Sq. Ft. R7 OR 49 CRMC-003413 Johns-Manville Service to Railroads Johns-Manville Insulating Cements OHNS - MANVILLE Insulating Ce to seal all joints between the blocks and J ments are composed of asbestos and to provide a smooth, attractive finish or binding materials that are low conduc a surface to which canvas may be applied tors of heat or efficient insulators. They if desired. are applied, when mixed with water, in Johns-Manville Insulating Cements are plastic form, producing an efficient insula also especially adapted for insulating ir tion when dry. regular surfaces where it would be im They are generally used as a surface fin practicable to apply sectional insulation, ish over block or sheet forms of insulation sheets or blocks. Johns-Manville Asbestos Fire-Felt Insulating Cement No. 302 Johns-Manville Asbestos Insulating Ce ment No. 302 is made of asbestos fibre and binding materials that have high insulat ing values. It is'easy to mix and apply, and readily adheres to hot surfaces. As : it is light in weight and high in insulating value, No. 302 is one of the most economi cal insulating cements manufactured. Johns-Manville Asbestos Insulating Ce ment No. 302 finishes with a hard, durable and attractive surface, and does not peel, crack or break off. Packed in 100 pound bags. Johns-Manville Asbestos Insulating Cement No. 400 > . Johns-Manville Asbestos Insulating- Ce- general use whre efficiency, strength and ,-ment No. 400 is a combination of asbestos durability are desired. Besides its high ..and. other; materials of high .insulating insulating efficiency, it provides a smooth, .value... It is an idealinsulating cement for ; durable finish. Packed in 100-pound bags. Other Johns-Manville Insulating Cements Johns-Manville manufactures and is prepared to furnish 85% Magnesia Insulating Cement, also Johns-Manville No. 364 and No. 352 Cements. The latter two cements are not as high : in insulating value as those referred to above and are generally used where a less expensive material is required. NOTE:--The efficiencies of insulating-cements cannot be given in definite figures because the efficiency of a given cement may vary greatly according to the manner of application, the form of the surface on which it is applied, etc. However, it may be said that for the better grades of insulating cements applied one inch thick on flat surfaces and at temperatures corresponding to average high pressure steam conditions (about 150 lbs.), the efficiencies vary approximately from 70% to 85%. 50 CRMC-003414 Johns-Manville Service to Railroads Johns-Manville Refractories and Cement Specialties CRMC-0034" 5 Johns-Maiwille Service to Railroads Johns-Manville Refractory Cements Nos. 31, 26, 32, 20, 30 and Super-Refractories Nos. 33 and 35 ODERN engineering, power plant M and boiler room practice is respon sible for higher temperatures in the quality or type of brick used. If only one face or surface of a brick is exposed to flame or heat the temperature may be in boiler fire box, and greater wear and ctreeaarsed to a point far beyond what the on boiler settings, bridge walls and baffles. brick would stand if the entire brick were Oil burners, mechanical stokers and surrounded by heat or if even small por mechanical draft all contribute to increase tions of the other five surfaces were ex power plant efficiency but result in more posed. The reason is that when only one severe boiler conditions. face or surface is exposed, the brick con The maximum efficiency that can be ducts the heat from that surface and there expected by modernizing boiler equip is a uniform drop in temperature from sur ment can be most nearly approached by faces exposed to the surfaces directly op building settings that are tight and do not posite. If more than one surface is ex allow air to leak through, bridge walls that posed to heat, especially a part of the four resist the action of flame and gases and adjacent faces, that part of the brick which baffle walls that do not allow the hot gases is surrounded becomes hotter than the to leak through or short circuit. balance of the brick and this difference in The life of a fire box or furnace brick temperature causes internal stress which setting .does not depend entirely upon the results in spawling. Cross-sections of Fire Brick Joints Fire Clay .joint . befote'l firing;,';. After firing. F.ire Clay joint opehv allowing -heat to attack front sur face .and portions of sides of brick- Johns - Manville Refractory Ce ment as mortar on the brick already placed. Upper brick placed and tapped down until JohnsManville Refrac tory Cement has squeezed out at edge of joint. i Finished "T" joint of Johtis-Manville Refractory Ce ment. After firing and vitrifying, the bending material forms a strong protection for the joint. Showing that when Johns-Manville Refractory Cement is used for setting up the brick, the edges of the brick are protected against the action of the flames. It will be noted in the illustration that the Johns-Manville Refractory Cement joint is shown thicker than the customary fire day joint. This is because it has been found that a three-sixteenth inch bond of Johns-Manyille Refractory Cement gives the best results because the greatest Strength is secured with this thickness and the desired elasticity to withstand expansion and contraction of the fire bricks is obtained. The fact that a Johns-Manville Refractory Cement bond will not disintegrate, crack and fall away under heat, which is the case with fire day joints, makes it possible to use this thickness of joint. 52 CRMC-003416 Johns-Manville Service to Railroads An example of one and four adjacent surfaces of brick being exposed to heat is a fire-brick setting in which the fire-clay or bond between the brick has given way, either on account of the bond s having melted out because of its inability to resist heat or having crumbled and fallen out on account of its inability to resist expan sion and contraction. This falling away of the bond allows heat to come in contact with parts of the four brick surfaces adja cent to the face that forms the inside of the furnace setting. (See cuts on page 52.) The thickness of the bond between fire bricks is often reduced, sometimes to practically nothing, but this method throws all stress due to expansion and contraction upon the brick itself and gen erally causes the brick to crack; It is obvious that the ideal refractory bond for setting up fire bricks would be one that resists high temperatures and ex pansion and contraction without melting or disintegrating and which possesses the quality of resiliency which would allow the fire brick to expand and contract with out damage to the brick or bond. The use of Johns-Manville Refractory Cements, which are composed of highly refractory materials, is not limited to the setting-up of brick work. When baffle walls, dampers and other molded pieces which are to be subjected to high temper atures are built with these cements, ad ditional boiler efficiency is obtained on account of the practical elimination of heat leakage. Moreover, the life of the molded pieces and dampers is greatly in creased. The use of our refractory ce ments for these purposes is explained on this and following pages. Johns-Manville Refractory Cement No. 31 For setting. up fire brick of boilers, and all sorts of furnaces. It begins to vitrify ; at 1450 F., and will withstand the action ` of flame and:heat, without fusing or melting, to a temperature of 3100 F. This is as high; a temperature as is usually encountered in fire boxes or furnaces. Johns-Manville Refractory;Cement No. 31 is packed in barrels and 100 lb. bags. Directions for applying Johns-Manville Refractory Cement No. 31 When preparing mortar made of No. 31 Refractory Cement: Mixture must be kept thoroughly mixed and free from lumps. Use as little water as possible. Depend upon thorough mixing rather than excess water to get a workable mor tar. "Butter" or trowel cement on brick al ready placed. Then lay brick and tap un til joint between brick is about three-six teenths of an inch thick and the cement squeezes out between edges. Do not point up or cut off cement that squeezes out between edges, but plaster and trowel it back over the face of the joint and brick so that it protects the edges of the brick, making a "T" joint. 53 CRMC-003417 Johns-Manville Service to Railroads Johns-Manville Refractory Cement No. 26 Possesses certain properties that No. 31 lacks and should be used where conditions require a cement with such properties. It begins to vitrify at 900 F. and must always be used for brick settings that are to be subjected to temperatures from 900 to 1450 F., as No. 31 does not begin to vitrify until temperatures reach 1450 F. No. 26 will withstand temperatures up to 2600 F., so may be used where temper atures range from 900 to 2600 F. It is stronger than No. 31, and therefore should be used in preference to No. 31, provided temperatures do not exceed 2600 F., not only for setting fire brick but also for molding into slabs, walls or pieces that are self-supporting. Johns-Manville Refractory Cement No. 26 is packed in barrels and 100 lb. bags. Directions for applying Johns-Manville Refractory Cement No, 26 When setting brick: Mix water with cement to get proper mortar consistency, Mixture.must.be kept thoroughly mixed and free from lumps. Use as little water as possible.. Depend upon thorough mix ing rather than excess of water to get a workable mortar. "Butter" or trowel the cement on the brick .already placed, then lay brick on top .and tap until joint between brick is about thick and cement squeezes out be tween edges.; Do not pointVup ;or cut .off cement that squeezes out between edges, .but plaster or trowel it back oyer the: face .of the joint and brick,, so that it protects the edges of the brick, making a "T" joint.. When No. 26 is to be used for molding dampers, slabs, door linings, etc.: Mix sufficient water, but not too much, until the mixture has a consistency of dry mold- ing sand, and is absolutely and thor oughly mixed and free from lumps. Tamp cement in mold, or in place, sol idly; then dry gradually with a slow fire till all water has evaporated. After all water has been slowly driven out, the slab or molded piece may .be subjected to tem peratures in excess of 900 F., which will vitrify, it. Large .molded pieces should be re-im forced by surrounding /the -edges with an., iron hand or frame and by running iron bolts or rods through the slab. All such rods should be covered or wrapped with asbestos paper to a thickness of about Via"- This allows for expansion of the iron. Johns-Manville Refractory Cement No. 32 Made for coating the face of brickwork exposed to flame and heat, and will withstand any temperatures from 1250 to 3100 F. It may be used both as a bond between, and coating for, fire brick setting if brick is dipped in the cement instead of applying the cement with a trowel, as Nos. 31 and 26 must be applied when used as a bond. Johns-Manville Refractory Cement No. 32 is packed in barrels and 100 lb. bags. 54 CRMC-003418 Johns-Manville Service to Railroads Directions for applying Johns-Manville Refractory Cement No. 32 To prepare No. 32 Cement for use, mix sufficient water with the cement to get proper consistency. The mixture must be kept thoroughly mixed and free from lumps. If cement is to be applied to the surface of the fire-brick settings or walls, apply it with a stiff brush or broom. If saggers or brick are to be dipped, dip each brick or sagger separately. When setting up brick which have been dipped, rub the brick, when placed, to a tight joint. Amount of water required for mixing can best be determined by trial, as the porosity of the brick or sagger to be coated or dipped largely determines the proper consistency. A porous brick requires a thinner mixture than one not so porous. Use a mixture that gives a coating about %2" thick. Johns-Manville Retort Cement No. 20 Johns-Manville Retort Cement No. 20 may be used as a refractory in connection with temperatures up to 2000 F. This cement is. furnished in plastic form and sets, hard when air dried. It is; admirably adapted for patching or filling cracks be tween . boiler door frames and boiler set ting and for general use around gas works and chemical plants: wherever a cement is required that must resist acid fumes as well as heat. On account of its combined refractory and acid-fume-resisting quali ties it is recommended for use in setting up brick smoke stacks. Recommended for use as a Front End cement. : Packed in 1, 5, 10, 25, 50, 100, 200, 450 and 800 lb. containers. - v Directions for applyi Johns-Manville Retort Cement No.- 20 This cement 3s furnished. ' in ready-c If only a portion of -the contents of the mixed form, and can be used directly from container is used and it is desired to hold the container. it over for another job, cover the cement If It requires thinning, add water gradr with a wet cloth' or a thin seal of water, ually, mixing thoroughly as the water is replace cover to exclude air as much as added. . possible and store in a cool place. Johns-Manville Refractory Cement No. 30 Adaptable for a one-piece lining in cruci ble furnaces and for general metallurgical application. It begins to vitrify at 1850F. and is resistant to temperatures up to 3000 F. Being a carbon base cement it will give best service in a reducing at mosphere. It offers excellent resistance to slags, and is recommended for patching along the slag line. It is not highly acted upon by either basic or acid slags. Where an excess of air is admitted to the combus tion chamber No. 33 Super-Refractory should be used. Johns-Manville Refractory Cement No. 30 is packed in barrels and 100 lb. bags. 55 CRMC-003419 Johns-Manville Service to Railroads Directions for applying Johns-Manville Refractory Cement No. 30 Crucible Furnace One-piece Lining Mix cement with water to consistency of moulding sand. A form made of wood or heavy 14-gauge sheet iron, well oiled, should be set inside of the furnace, allow ing space of not less than two and one-half inches between form and shell of furnace, or whatever thickness of wall is desired. Cement should be filled in and rammed solidly. Wooden form, if used, should be burned out. Iron form, if used, should be removed carefully. Use slow fire to evaporate all water, then temperature should be raised grad ually to the highest point. Laying Fire Brick Add sufficient water to make the cement between the bricks should be spread back about the consistency of mortar. Trowel about one inch on each brick, making a mortar on about one-quarter inch thick so that when the succeeding brick has been tapped into place sufficient cement will re "T" joint about three-sixteenths of an inch thick, to prevent the flames from im pinging on edges of bricks. main between the bricks to seal uneven Always mix thoroughly until free from surfaces. The cement that protrudes from lumps.: Johns-Manville Super-Refractory Cements Nos. 3.3 and 35 Steady improvement in:methods of fuel, chemical action, and: they will not be af- burning, melting: of metals, etc., is, largely , dected by molten yellow metals, such as responsible for the extremely high temper- brass, br0nze,; etc. atures that are now encountered daily; both in special process work and' even in the fire boxes of oil-burning boilers, etc. We have produced two super-refrac tory cements which will withstand these severe conditions. They possess one of the most important qualities required of such a cement--the ability to stand up under These cements are particularly well -adapted for use in connection with elec trical and special furnaces. No. 33 may be used where temperatures range from 1000 F., its vitrifying temper ature, to 3300 F., the highest temperature it will withstand. these high temperatures with compara No. 35 may be used where temperatures tively little shrinkage. This reduces the range from 1200 F., its vitrifying temper possibility of cracking under severe tem ature, to 3500 F., the highest temperature peratures. it will withstand. Because of the character of these ma- Nos. 33 and 35 Super-Refractory Ceterials, there is very little possibility of ments are packed in 100 lb. bags. 56 CRMC-003420 Johns-Manville Service to Railroads Directions for applying Johns-Manville Super-Refractory Cements Nos. 33 and 35 When preparing mortar made of No. 33 or 35 Super-Refractory Cement, material must be kept thoroughly mixed and free from lumps. Use as little water as possible. Depend upon thorough mixing rather than excess water to get a workable mortar. Johns-Manville PR-15 Plastic Refractory Cement PR-15 may be used for temperatures up to 2600' F., its highest working tempera ture. This cement is furnished in plastic form and sets hard when air dried. It is recommended for patching boiler settings, baffle walls, refractory linings in gas plant and coke plant equipment, and wherever a refractory lining or wall has broken or worn away, if the thickness of the patch does not exceed 2" and if the temperature is less than 2600 F. Patches over 2" thick or for temperatures above 2600c F. must have some other 'Jdhns-Manville Refrac tory mixed with PR-15. The addition of PR-15 gives greater strength and density when air dried and before partial vitrification, and greater adhesion, to other Johns-Manville Refrac tory Cements. PR-15 may also be used as a mortar in setting up bricks in furnace settings, ovens or kilns, gas plant and coke plant equip ment, etc., when temperatures are not high enough to vitrify other Johns-Man ville Refractory Cements. PR-15 is packed in 100, 250, 45G and 800 lb. containers. Technical Data--Qualities of Johns-Manville Refractory Cements Lowest working temperature or low point of vitnfaction.'.. ! . . Highe'St w.orkm'gjtemperatvtfe,... ilyVi-;. .. Melting point'..';i ..Complete fusion (dry pow'dfer.). .. .>i(:;. No. 20 . Retort 900:F* 2000'F . 22.5.0:F . 2250-F. No. PR-1S 800?^ : 2600 2700 2750s. Specific gravity:j. . .... . 1.84 - . Weight in lbs. per cu. ft.;-dry moulded powdered Approximate capacity: lbs. required for'1 setting 1,000 bricks, with !5Jrj" thick-' ness of joints............ .. .:.................... 400550 '^''Approximate capacity: lbs. required per hundred sq. ft. to coat the surface of fire brick settings 5:.V' thick 2.06 450600 No! 26 No. 30 No. 31 900 1850 2600" 3000 27t)0 . 3050.. 2750 ; 3ioo 1450 3100 . 3182 .3254. 1.68 105 7.7. 1.85 116 78 , 1.76 110 99 500650 660850 550700 No. 32 1256 3100 3146 3200. 1:77 80.1 ... 90 No. 33 . No. 35 1000= 1200 33005".' 3500 . . 3350 :: -3542 3362 .'3570, 1.65 121 103 1;6Q .121 . 100 . 670850 670850 Character Linear shrinkage at 2250F. ''per cent of length of dry sample before heatmg............................................................ Free and combined silica content (r{ ) Free and combined carbon content (', () Acid 3.3^* Acid Semi-acid Neutral Semi-acid Semi-acid Semi-acid Neutral 2.0*** 1.5 46.77 0.0 1.4 13.9 74.4 2.0 55.11 0.0 4.5 52.5 0.01 1.0 50.0 0.0 0.0 9.5 0.0 ' Sets hard when air dried. '* Quantity of No. 32 cement required for coatinq varies a great deal, depending upon the- porositv of the brick. Above quantity, 90 lbs. per 100 so. ft. of surface, is based on average conditions and when the cement and water are used in enual quantities, i. e,, 100 lbs, cement and 100 |bs. water. *'' Shrinkage on air drjdng. 57 CRMC-003421 Johns"Manville Service to Railroads Johns-Manville Monolithic Baffle Walls OILER baffle walls which are not B perfectly tight allow some of the heat-laden gases to take a short-cut from the fire box to the stack. Such escap ing gases carry away wasted fuel. Full value from the fuel burned can only be re alized with leak-proof baffle walls. The effectiveness of Monolithic Baffle Walls built of Johns-Manville Cement is very convincingly illustrated in the diagram, showing a solid wall or slab molded to fit closely around the tubes, with absolutely no joints or cracks.. The leakage of heat-laden gases, through, such a wall is impossible, particularly as it is built of a strong, durable material that will resist the stress :.arid high temperature incidental to this service.; ' .-ft- the boiler, whereupon the wooden forms will burn out, leaving a solid monolithic refractory baffle wall, which eliminates leakage of hot gases. Johns-Manville engineers are available for making suggestions with regard to the application of the various Johns-Manville Refractory Cements for building mono lithic baffles in water tube boilers. ; The Monolithic Baffle Wall is constructed by first eliminating the existing wall, in case of an old boiler, and then placing wooden forms or walls four or five inches apart, where the baffle is desired. Johns-Manville Baffle Wall Ce ment, mixed to proper consistency, is then poured and tamped be tween the forms. After the mixture has dried completely a slow fire should be started in How Johns-Manville Monolithic Baffle Walls effectively direct the flow of the gases of combustion and eliminate "short circuiting" and heat losses. 58 CRMC-003422 Johns-Manville Service to Railroads Johns-Manville Aertite Boiler Wall Coating TOUGH, rubbery coating in plas A tic form used for covering the out side of boiler walls to prevent the Sheet or block insulation properly ap plied to boiler walls is of course the most satisfactory manner of preventing infiltra infiltration of cold tion of air through the boiler walls, air into the com and the radiation of heat from their bustion chamber. surfaces. However, if such insula Cracks and crev tion is not applied the infiltration of ices in boiler wall air can be elimi settings mean nated at a compar lower efficiency atively small ex and higher operat pense by the appli ing costs. While many cracks are quite small they will allow sufficient leakage to lower immediately the boiler efficiency,' Cold air,,)that leaks in. absorbs .heat im-: tii - it reaches- the :teinperature of the furnace; gases' and hence wbstes heat that : would other wise perform use ful work. It is con servative, to esti-. mate on the fol lowing basis -- if . HOW TO TiEST/A BOILER WALL Fasten a'squa're of cardboard having a small aperture at its' center over a woodeii. frame. By pressing, this/ frame against a boiler wall, with the edges temporarily but completely sealed by some plastic material, any leakage in this part of the boiler wall will immediately be detected by the inrush of. air at the small aperture., A candle, flame held to this aperture will be sucked in ward if there is an infiltration of air through the boiler wall. By this method, an entire boiler wall can be very quickly tested. cation of JohnsManville. Aertite Boiler Wall Coat ing. . . It forms a tough, rubbery coating or blanket over the entire boiler wall setting which re-, mains tight on ac count of its adhe sive a'ri d ductile qualities. 11 i s easily applied with a trowel. Best results are obtained by keep ing the thickness air leakage as near Vie" as through boiler walls amounts to only 5% possible. Amount required for Ylg" of the actual quantity of air required for thickness--25 to 40 lbs. per 100 square proper combustion and high efficiency-- feet, depending upon the number and va- 1% of the fuel burned is wasted. However, riety of cracks and the way the wall has leakage often amounts to far more than been pointed up. 507c and, figured on the above basis, the Furnished in 25, 50, 150, 300 and 500 lb. fuel wastage is correspondingly greater, containers. Prices on application. 59 CRMC-003423 Johns-Manville Service to Railroads Johns-Manville Leak-No Metallic Compound CHEMICAL metallic compound A for repairing and closing holes and leaks in iron or steel, prepared in Johns-Manville Leak-No differs from all other compounds made for similar pur poses in that it does not adhere as a ce powdered form and used by mixing wmithent, but amalgamates with the metal it water to a stiff putty. It metallizes in a self and makes a permanent repair. It few hours and becomes a part of and the will hold high pressures, will not flake off, same color as the casting to which it is and will resist any heat, acid, gas, or oil applied. that iron will stand. Johns-Manville Ferrotite Cement A liquid for stopping up sand holes and three hours is poured out, and the casting spongy spots in castings. Ferrotite is allowed to stand two or three hours before poured into the cavity and after two or using. Excess material can be used again. Johns-Manville FI-O Pipe Joint Cement A powdered material which may be makes a tight and, permanent joint, mixed with linseed oil and used for making By mixing with water it can be used as ;tight joints, for all pipe work* such as a putty for: connecting sink wastes, base- steam, gas, water and air. . merit plugs, bowls,hath plugs, etc. Economical, -.non- poisonous^ stainless, : Also furnished.ready mixed with linseed, does not cause a bad taste in water, and oil.. Johns-Manville Fireite Asbestos Furnace Cement A strong and durable cement for setting a few hours after application. When sub-. up-and. repairing broken joints in. furnaces, . jected to heat ityitrifies without shrinking -ranges; heaters and stoves. .It is.prepared or becoming porous. It is inodorous, and. ready for use, adheres: readily and firmly effectually prevents escape of smoke, to castings and sheet metal and "sets" in gases and dust, thus insuring perfect draft. Johns-Manville Phoenix Asbestos Stove Lining This is a perfect substitute for, and a great improvement upon, the old style of stove-brick for making new linings and re pairing cooking stoves, ranges, heaters, etc., also for lining doors of boilers and furnaces. It costs less than stove-brick, is always ready for use, will conform to irregular surfaces, can be easily applied, does not easily burn out and clinkers do not tend to adhere to it. Much time, and often ser ious injury to the stove, may be saved by having Johns-Manville Phoenix Lining on hand and not being compelled to send to distant points for stove-brick. 60 CRMC-003424 Johns-Manville Packings 61 cRMC-003425 Johns -Manville Service to Railroads Johns-Manville Sea Rings JOHNS-MANVIUE S6A RINGS Note particularly the flexible lip and hollow space back of it which make the action of Sea Rings automatic^ Cross-section of stuffing box showing Sea Rings in place. O R packing Tods- and outside packed plungers against;, steam,. water,: air, .brine and. any. other Ruid that will not attack the. materials used in their construe^ tion. Furnished inr ring form only. Long life and service arelobtained from Sea Ring Packing.,; because, i by preventing unnecessary : pressure ; and friction be tween rod and packing, needless wear is eliminated. Johns-Manville Sea Rings are made for rods. or.-plungers ih diameter or over, providing flange or space between rod and stuffing-box is %" or rrtore. The action of Sea Rings is absolutely automatic. They press against or grip the rod only when there is a tendency to leakage through the stuffing-box. The pressure through the box acts on the lips of the packing and in proportion to the pressure. Leakage is prevented because the flex ible lip more readily conforms to rod or plunger than the inside surface of an or dinary solid packing. Loss of time and expense due to shut downs and labor cost of renewals are re duced to the minimum, because of the dur ability of Sea Rings. The elimination of unnecessary friction where Sea Rings are used means great economy, on account of the saving in power required to drive the apparatus. The data and curves shown on page 63 conclusively prove the economy of Sea Rings even when good packing of the ordinary type may be purchased for less. Sea Rings assist in Packing Standard ization through the elimination of a num ber of packings for various conditions, be cause they are constructed of materials that make them the best packing obtain able for nearly all conditions encountered where rod and plunger packing is re quired. 62 CRMC-003426 Johns-Manville Service to Railroads Saving Power by Eliminating Friction TREMENDOUS amount of power A is wasted in the operation of pumps, engines, compressors, etc., because the pressure of ordinary packing on a rod or plunger is always constant and maxi mum, irrespective of the fact that the ten dency to leakage or pressure through the packing is usually variable. See 7ft 7" 6st 6c* S*c y K 5 j% s* &wf /S. a> s? af ag ta a Relative Cost of Packing and Operating with Flax and Johns-Manville Sea Ring Packing Rodins vtmcaJly up each space repretenu JJ0 0&. Reading herixofitally to the sight etch ipact rprf**At ipaeci seprewnt one week two Description of P.ump frjmp--GouWi Triplex Dmm by JJ* Hikr mnni'4 DnnMtiR<%P*t,hMt*mn phagm IlK* diuMlef Sud'c*' i* Vcvv?*.. Pre^hut 3S M ft*. Pmcurr. n*i. 4Wo#--C E Thm Phut 440 Vdl.liM.P J4*r*e--E>urliiw vmVdr a h Irh h**d id* of eSan, th fat te spec* iKH, **!('f ihe (1*1 peckv*,* d iri I\yi ipn xrpmcot Pits CO.th< iRvil or$e R*i P*&-rt c*%\ of $f *3*4 Pirt^g !'< ifc* eec* >N( fl*ar lhp*aciku<>nU(> o* k*U' m- 34 3 30 4* 4S 4Z 43 J* St 0-* 7*> 7-" &*> sst ** 4Se<*i 'j 'T^e actual coat of power (in .this ease 'electric current) i* added continually 10 that*'readinCiUp\fronP'a,ny'p6int'oni the horizonla] line (he total ce*Cof,the packing and current con* 'turned for the'given period' of'operation is obtained.' EXAMPLE?--Taking the 20*Week* of Operation*, the total cost ' Where ftax w.as used Is $297,00 and where,Sea Pings were.used $326.00.;. At the end of the 29th week the cost of packing and operation would have been identical if .the. stuffing boxes had not been re-packed with flax. From lhi..time on. a net saving was effected; and oh the,aame basis at the end efthe 52nd week, the* coat of flax and,current was $738.85 and',the. ' 'cost of ea Rings and current $666:12'. NoletThis is an actual saving of,$72.73 during a peiiod of On'e year.' As a matter of fact, the flax packing .never lasted over six months*so that an other $20.00 had to be added at (he end of ihe_26ih week to the curve represent*, tnglhe total cost of As% packing and eorrent'consumption. iThe 'dotted line has been drawn to show that even tf the fiax p acting lasted a* year, Sea Rings effected a sotable saving aflex the 29lh week, but with the additional cost of tepacking with taxa marked net saving was effected by Sea.Rings after the 26lh week which at the and of the 32nd week, or a year, amounted to $92.73. Note that this swing U net--that is, the saving is clear profit after the additional <oii of Sea Rings has been allowed. 3E 3? E3d 46 Ur 7JW iff Is, 2ft Electrical Current Consumption and Packing Costs Following data compiled from records made during Sea Ring test at Tide Water Paper Co., as shown in the chart above. A--It costs $40.00 to pack a triplex electricaldriven pump with good grade braided flax for 1 year (2 packings per year at $20,00) each). See note A, page 64. It costs $718.85 to drive the same pump with electricity for one year. (9.6 K.W. per hour, 24 hours per day--144 hours per week--7488 hours per year=71,884.8 K.W. hours, @ 1c per K.W. hour=$718.85). 63 CRMC-003427 Johns-Manville Service to Railroads B--It costs $115.00 to pack same pump with. Sea Rings for one year. (Sea Ring packing will last longer. See Note B, below.) It costs $551.12 to drive pump with electric ity, one year, same number of hours as above. (7.36 K.W. per hour--55,111.6 K.W. hours at lc per K.W. hour.) Saving in cost of power to drive pump packed with Sea Rings for 1 year. .$167.73 Premium paid for Sea Ring Packing (difference between cost of Sea Rings and Flax, $115.00--$40.00) . . 75.00 Actual net saving first year accom plished by the use of Sea Ring Packing...................................................... $92.73 This is a return of more than 123% on the $75.00 premium paid for Sea Rings. Note A--Two packings of flax a year is conservative as pump was actually packed with flax every 4 months. Note B--These Sea Rings were in service from November, 1917, to November, 1922. As Sea Rings lasted five years--the last four years they saved-- Eight packings of flax at $20.00 each.$160.00 67,092 kilowatt hours at lc each......... 670.92 Total additional net saving in four years ............................................................ 830.92 Net saving first year was....................... 92.73 Total net saving for five years is... . 923.65 Also note that actual cost of Sea Rings ($115.00) is less than the cost of 10 flax packings at $20.00 each, or $200.00 Do not overlook the fact that electrical current saved per year was 16,773 K.W. hours. This means that the pump packed with flax consumed 30.4% more current than when packed with Sea Rings. Sea Ring Service T costs more to pack a stuffing-box with I Sea Rings than with any other packing r---except some types of mechanical Rings. Combined, the saving afforded by Sea Rings amounts to a large return on the investment. (metallic) packing. .'% .; = :: ; . The life of Sea Rings depends upon the But the: service^rendered by Sea Rings service to which they are subjected, and makes them: the most economical packing . in drawing conclusions from test, data to purchase andvUse.; -/ their life should, be compared to the life of other packings used under identical con This service is due; to - their automatic ditions.;/ vv;:f;;;%/v : V- action/.which reduces friction .to the mini The saving of: power by Sea Rings is in mum, and so reduces wbar ori 'the; packing disputable, and-; easily determined and and power required to /dr/ive the rod back checked by measuring.-the/power required and fortli through the packirig/ / ;. : to drive a machine Before and after it is Either I service alon.e^-that: of long life packed with Sea/Rings/ or that of. power- saving--^will effect suffi See chart and data on this and the pre cient saving to justify the purchase of Sea ceding page. Sorne examples of service rendered by Johns 'Manville Sea Rings Hot Water Service Outside packed boiler feed pump at American Steel and Wire Consolidated Works, Cleveland: Plungers 12" in diameter, pumping hot water at a temperature of from 210 degrees to 212 de grees against a boiler pressure of 175 pounds. Two sets of Sea Rings were in service on the above pump for five years. Air Compressor Service A set of Sea Rings was installed at the foun dry of a large electric company in January 1919 on the high pressure rod of an Ingersoll-Rand Compressor. This compressor operates at 257 R.P.M., the greater part of the time for 24 hours a day and 6 days a week, and develops 100 lbs. pressure. These Sea Rings were replaced by new ones on March 26th, 1922, having required practically no attention during their lifetime. Centrifugal Pump Service Sea Rings used on a Wilson-Snyder centrifugal pump operating under varying speeds, from 750 to 1350 R.P.M., at one of the plants of a large steel company have lasted nine months and over where formerly the ordinary packing used was replaced weekly, and a brass sleeve, used in the stuffing-box, replaced every two weeks. 64 CRMC-003428 Johns--Manville Service to Railroads Directions for the installation of Johns-Manville Sea Rings SET of Johns-Manville Sea Rings is usually A composed of one header ring, several Sea Rings and one follower ring. (See tags at 8. After all Sea Rings are in, install last fol lower ring, so tagged, and as arranged in set when received, so as to fit properly against tached to rings.) The number of Sea Rings used last Sea Ring. depends upon the depth of the stuffing box. 1. Remove old packing and clean stuffing box. 2. Install first header, so tagged, and as ar ranged in set when received, so first Sea Ring will fit properly against it. See that it is pushed back so all of it is seated against bottom of box. 3. Install Sea Rings with lips toward pressure, 9. Excessive gland pressure on Sea Rings will tend to distort the shape of the rings and reduce their efficiency and life, but it is also just as important that the gland presses against the packing with sufficient force to prevent movement of the packing in the stuffing box. or back of box, joint of each ring to be on opposite side of box from joint of preceding ring. 4. Do not pull ends of rings straight apart, but separate them sidewise to, pass over rod.. .. 5. Work two ends of rings into .box first, then, remainder of ring. 10. Packing gland nuts should be frequently inspected and always kept tight enough to prevent any movement of the Sea Rings. Such motion will cause wear on the outside of the ring, possibly twisting or cocking of the ring in the stuffing box, and eventually a.failure.; 6. See that each ring is completely seated be- fore installing next ring;;. 11. After Sea- Rings, have .been in service their 7. Never' cut'off ends or' any. part `of tings,, size or volume may -be reduced, to some. ex-. which are-made toVfit tight ;against inside'of .. tent on account:Of' wear, and if such, is the ' box.- ; case this ^necessitates' taking up the gland. Specifications wFbr those ivho desire to specify by description ) ' : Each 1 set of packing shall have 'inside,' outside : degrees with; the axis: of the rod or plunger ' and depth dimensions'suitable for the. rod and packed. '. stuffing box for which it is .intended, and is to. The design and construction of the packing consist of several packing rings and not less than must be such that its action is positive--that is, one or more than two auxiliary rings or headers. the pressure of the packing on the rod or plunger The packing rings of each set shall be con structed of a suitable fabric and friction or rubber cement for binding the plies of fabric together, and each ring shall have a **UM formed section having a thick heel on one side and a tapering, flexible lip or tongue on the other side. The thick heel shall be harder than the lip, which shall be flexible so as to conform to the surface of the rod or plunger which it packs. must be dependent upon the pressure through the packing or stuffing-box and not dependent upon the pressure of the gland on the packing. The auxiliary or header rings shall be of such construction and shape as to provide suitable seats for the first and last packing ring in the box to rest against. The above described packing is not to be fur nished where the space between the rod or plunger and the inside of the stuffing-box is less The end of the heel shall be beveled or molded than 3/g of an inch or where the diameter of rod so that it makes an angle of approximately 75 or plunger is less than 3' Gf an inch. 65 CRMC-003429 Johns'Manville Service to Railroads 0 Johns-Manville Kearsarge Rod Packing Spiral Style No. 166 Ring Style No. 150 OR packing rods where space be F tween rod and inside of stuffing box is %" or over. The asbestos and other materials used and the construction of Kearsarge Rod Packing make it suitable for steam or air at any temperature and pressure, which . eliminates the necessity of using several the rubber expansion back on top and covering the block thus formed with two wraps of asbestos cloth. There is no chance, even if cover wears away, for part of the packing to get loose and work away, for the center is folded from one piece of fabric--each layer a continuation of the adjacent one. packings for various steam and air condi When cover wears, away, the first fold is tions. This means a minimum stock and . presented to wear, and this is as strong the convenience of having one; packing for and durable as the cover itself, for it is many conditions. ' made of-the same material. Flexibility and resiliency: rare assured: There is .no rubber cement in the block . throughout the life of;Kearsarge -on ac- . or body, which entirely- eliminates the - count of its peculiar folded block or cen .possibility of its- becoming hard by vul ter construction, by the rubber expansion canization. In assembling, the cover is so v back: or cushion which, adds resiliency, placed . that it is impossible for it to be : and: because ; rubber;; cement, is entirely pulled of torn away from the body in ser ' eliminated from the center; block of: the vice. . packing. Sizes and smaller, furnished with a <. Kearsarge is Constructed.- differently : twisted core instead of the folded block from other asbestos packing which may construction. have the same exterior appearance. The Furnished in Ring Style No. 150 and block is formed byfolding unrubbered as Spiral Style No. 166. bestos cloth (same quality as used for the Jfithout rubber expansion back, Ring outside cover) back and forth, placing Style No. 15 and Spiral Style No. 16. Kearsarge Rod Packing is packed as follows: Ring--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights: Under 1" 1" to 2" 2" to 3" 3" to 4" Over 4" rod............................... rod............................... rod............................... rod............................... rod............................... 3 pounds 5 pounds 10 pounds 15 pounds 20 pounds Spiral--Furnished in boxes, each containing one length of packing approximately 12^ feet long. Approximate u-eight per hundred feet of Kearsarge Packing treated with preserving liquid and graphite finish: 3/6"......................................................13'4 pounds y2"......................................................20 pounds `6''......................................................32 3 1"......................................................44 pounds pounds 7 6".........................................................57 1"......................................................71 pounds pounds 66 CRMC-003430 Johns-Manville Service to Railroads Johns-Manville Duplex Rod and Plunger Packing Coil Style No. 371 Ring Style No. 372 OR packing rods and outside packed Fplungers where space between rod and inside of stuffing-boxor are high because the layers of rubber cement between the seyeraPlayers of flax fabric form waterproof walls that prevent- over, against hot or cold water, at alt pres- leakage through the packing. . sures and temperatures. - _ .. ,, Flexibility and resiliency, are assured The. flax and rubber material used and on account of these same layers of non- the : construction of Duplex; .Rod - and vulcanizing rubber cement and because of Plunger: Packinglmake it- suitable, for. rod. the rubber core iri-the cente'r of the pack- and outside-packed plunger hydraulic ing. v ; service. ,:v ; . Maximum durability ..and,-efficiency; are., .. johns-Manville. .Duplex;: Rod and Plun- obtained because of the woven wearing ger Packing; is extremely durable, because . surface and. because of the. resiliency or the cover orwearing surface is made of life of the packing,, which makes the stuff- a fabric of tightly twisted, closely woven ing-box tight with the minimum amount flax yarn, which wears better?than the sur- of gland pressure on the packing. face of packing braided like ordinary flax. ^ . , . '. ,, J' Furnished in Goil Style No. 371, Ring The waterproof qualities of this packing Style No. 372 and Spiral-Style No. 373. Duplex Rod and Plunger Packing is packed as follows: Ritiu--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights: Under 1" rod................................... 3 pounds 1" to 2" rod.................................. 5 pounds 2" to 3" rod................................ jo pounds 3" to 4" rod.................................. 15 pounds Over 4" rod.................................. 20 pounds XIay he ortiered in sr(s In lit rod and >tud':nbov Spiral--Furnished in boxes, each containing one length of packing approximately 121. feet long. (`.nil--Furnished, several coils to the box, the number depending upon the size of the packing. .Ifjpro.vuiuiU; icWtdif per hundred feet of Duplex packing treated with preserving liquid and graphite finish: 3A"............................ Vz".................. .......................... H"............................ w............................ .......................... V%.................. i"............................ .......................... 17 34 52 pounds pounds pounds pounds pounds pounds 67 CRMC-003431 Johns-Martville Service to Railroads Johns-Manville Mogul Coil Packing Twisted Style, No. 193 Braided Style, No. 222 OR packing small rods, valve stems, Mogul make it suitable for nearly any Fetc., and where space between rod, condition. It is a convenient all-aroundstem or spindle and inside of stuffing- the-plant packing, specially recommended box is less than or for packing condfoir packing, small rods and boxes, or for tions such as for oils and chemicals where no rubber is desired in the packing. Made of long fibre asbestos yarn, twisted or braided into coil form, lubri emergency use. ; By untwisting the strands of Style 193, many smaller sizes may be obtained. cated and gr.aphited..: The asbestos, yarn Furnished in coil form only, on spools ..and -lubricating compound' used;in the and reels--Twisted Style No. 193; Braided manufacture; of both braided and twisted Style No. 222. - MOGUL PACKING IS PUT UP AS FOLLOWS: Sires ' and ,. . ... ._____ __ .both styles, on % lb. spo.ols, each spool in an individual carton-,'and packed 50 spools to a large-carton'. , Sizes W'M. JA".......................................... ..........both styles, on .1 -lb. spools,- or larger. Sizes over. y2 ......... l?oth styles, on-5 lb. spools, or larger. - APPROXIMATE WEIGHT OF 100-FOOT LENGTHS Si2e Inches Approximate Weight, pounds per 100-Foot length of Twisted No. 193 Approximate Weight, pounds per 100-Foot length of Braided No. m Vs ........................................... ................................................ JA ....................... ................................................ lJ/4 .................................. .................................................. 314 .................................. V/a Vs ........................................ ^ ........................................ SA ...................... ................................................ 7/4 .................................. .................................................. ................................................ 1254 .................................. .................................................. ................................................ 2454 .................................. 7 Ya 11^4 h\ CO <N 3/a ........................................... .................................................. 30J4 Vs ........................................ ................................................ 40 l ........................................ .................................. .................................................. A2% 6S CRMC-003432 Johns-Manville Service to Railroads Johns-Manville Universal Piston Packing Cross-section of Coil Style No. 33, end opened to show construction. Spiral Style No. 34 OR packing the pistons of inside Fpacked pumps against water, brine, air, oils and some chemicals, where The folded construction gives Universal greater flexibility, resiliency and ex pansion in the direction desired, which packing space is %" or over. A combina- also means longer service and less leak- tion of asbestos and cotton fabrics folded age or slippage past the packing when the and molded;together so as to present a pump is in service, wearing surface of rounded shoulders of most durable material. The back and = , The rubber cement that holds the folds : forth folded construction of Universal o Universal together is strong and tough. / Piston Packings makes it superior to the packing.is vplcaniz^d in steel molds, laminated type of -Hydraulic packing for so the sizes are more accurate than the following reasons: v-V: laminated hydraulic packing which is cut . ... in strips from slab stock. Due to the As this packing is-made of continuous methods and materials, used- in construc.tr fabric folded back, and forth,, there are no jng Universal,..it is very durable and more separate,laminations, to work;loose from. .economical than other packings sold at a one.. another by the side-wiping action much lower per-pound price.'; against the pump cylinder walls. Thus ; : /'VU'. the life of this packing is longer than that , Coil Style No. 33; Spiral Style No. 34; of any. other hydraulic piston packing. Ring Style No. 35. JOHNS7MANVILLE UNIVERSAL PISTON PACKING IS PACKED. AS FOLLOWS . Coil--Furnished in .coils approximately 12 feet long, packed several coils to the box, depending upon the size of the packing and according to the following table: Size of Packing .................................................... 4 coils ' ir,"......................................................... 3coils A"......................................................... 4coils lie/......................................................... 3coils .................................................... 3 coils M v,"....................................................... 2coils z/\"......................................................... 2coils A'................................................... 2 coils 1"........................................................... 2coils perbox perbox perbox perbox perbox perbox perbox perbox perbox Spiral--Furnished in boxes, each containing one length of packing approximately 12 feet long. Ring--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights: Under 1" rod......................................... 3 pounds 1" to 2 " rod........................................... 5 pounds 2 " to 3 " rod........................................................... 10pounds 3 " to 4" rod.................. 15 pounds Over 4 * rod...........................................................20pounds May be ordered in sets to fit piston exactly. Approximate weights of 100-foot lengths of Universal Piston Packing: %"........................................................................ 10.5pounds A"........................................................................ 18.7pounds "A"........................................... 27.1 pounds H*........................................................................ 41.8pounds H"........................................................................ 52.0pounds 1"................................ 68.1 pounds 69 CRMC-003433 Johns-Manville Service to Railroads Johns-Manville Universal Combination Steam Hammer Packing Universal Combination. Rmgi Style No. 29 .< JOHNS-MANVIULE Steam Hammer , caused by dirt and grit, because the square Packing is a combination of asbestos, rings have -a wearing surface. of rounded cotton and rubber, and is well adapted shoulders instead of laminated edges, and '.to railroad,'and general shop service. The style of packing recommended depends upon whether the rod is round or has one all the rings are-made of a combination of cotton and asbestos fabrics which makes them most durable. The arrangement of or more flat sides and upon other condi- the variously formed rings makes the set tions Which vary considerably in different particularly flexible and resilient, and the shops. contraction and expansion caused by in- Steam hammer service is exceptionally termittent service are also taken care of severe on account of the unusual vibra- by this method of arrangement, tion, accumulation of dirt and grit on .. rods, and intermittent service, ihe lorms ^ of rings used in Universal--round, square, ' ^ J and diagonal cut--provide for vibration. Special sets can be furnished for rods The wearing surface resists the wear with flat sides. 70 CRMC-003434 Johns-Maiwille Service to Railroads Johns'Manville Jewett Ring Packing Style No. 20 Style No. 10 OR packing small rods and spaces Fwhere rings of exact dimensions are required or desired. Made of asbes it is impossible to make other styles of packing in such small sizes. All Jewett Rings are molded to exact tos, cotton or flax yarn (according to styslehape and size in steel dies, so that they and service), Jewett Rings are intended exactly fit rod and stuffing-box for which for packing small spaces, i. e., where the they are intended. They are made in space between rod, spindle or shaft and several styles for different conditions as the stuffing-box is less than Ys" ar*d where follows: Jewett Rings For any condition where a ring of-small crosssection ;i;s required or where a packing' with -no 'rubber in its composition is preferable ; i;: e., for some chemical solutions, etc. This style is m&de of wire-inserted asbestos yarn, braided into jack- ..ets one over another around a thin lead ribbon, lubricated, graphited and molded into ring fornu This is an ideakpacking for the-steam regulating; and overflow valve stems., of the Hancock inspir ator. Jewett Coil, Style No. 310 This-packing is: made. of exactly the same -ma is-: furnished in coil form. Especially recomterial, arid' by tHe. same method of .Construction as; : mended for use as. a.locomotive cab cock packing. Johris-Marivilie:Jewett' Rings, Style-No. 10, but (See page 77.) . . . Jewett Rings , Style No. 20 Only for conditions that require a ring with a small and rectangular cross-section, i. e.,^a very ' narrow flange or width and a depth or thickness several times greater, for example: 12r' inside diameter x y outside diameter x y&" deep. Made of Asbesto-Metallic cloth, folded into tape, cut to proper length and molded into rings. Jewett Rings Style No. 40 Especially adapted for hot water, light oils and except that flax yarn, without wire, is used in gasoline service. Constructed similar to No. 10 stead of wire-inserted asbestos yarn. Jewett Rings, Style No. 3 For hot and cold water service. Especially de signed for packing faucets, Fuller cocks and plumbing products. This packing is lubricated with mica instead of oil, so that it will not affect the process of nickel-plating. Made with jute center with a braided cotton jacket or cover and molded to exact size. Furnished in white finish. 71 CRMC-003435 Johns'Manville Service to Railroads Johns -Manville Universal Rod and Plunger Packing Coil Style No. 30 Spiral Style No. 31 Ring Style No. 32 kOR. packing rods and outside-packed plungers where space between rod arid box is ^4, of an .inch, or: more.-- steam,, air, water and various fluids, Specially adapted where a packing with. great resiliency'is required. .- Universal Rod Packing is made of as bestos and cotton fabrics, which have been treated with rubber cements, built up together arid Wrapped around a rubber core or cushion. THe combination of asbestos and rub ber produces a packing with great plia bility and resiliency which is suitable for steam, air, hydraulic and various other conditions. It is specially recommended for severe conditions such as high pressure hydrau lic work, service where there is a great deal of vibration or where rods may be in poor condition or- slightly out of align-; ment. "y- U. . .r Furnished in Coil style No. 30, Spiral style No. 31 and Ring style No. 32. Universal Rod and Plunger Packing is packed as follows: Coll--Furnished in coils approximately 121 J feet long, packed several coils to the box, depending upon the size of the packing and according to the following table: J4 *--8 coils. . . . V> "--4 coils. . . . 34'"--2 coils 5if;*--6 coils....'}jr,"--3 coils. . . . 78 "--2 coils %"--4 coils. . . . % "--3 coils.... 1" --2 coils -16*--3 coils., iff,"--3 coils Ring--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights: Under 1" rod........................................ 3 pounds 1" to 2 "rod........................................... 5 pounds 2" to 3" rod...........................................10 pounds 3 " to 4 " rod...........................................15 pounds Over 4 " rod.......................................... 20 pounds Spiral--Furnished in boxes, each containing one length of packing approximately 121-2 feet long. -1 .................... .................... -" ".................... .................... 1 pound, 12 ounces 8 ounces V'.................... .................... 2 pounds, bounces y,w.................. ..................... 2 pounds, 14 ounces n.r,".................. 3/)/ " .................... 7/ " 1"...................... 72 CRMC-003436 Johns-Manville Service to Railroads Johns-Manville Asbestos Wick Packing Furnished regidarly in y2 and ldb. balls Johns-Manville Asbestos Wick is made in six standard styles: Style 4195--A single strand asbestos wick for ordinary requirements. Style 195--Canadax, commercially pure asbestos wick made of several strands twisted together. Style 199--A wick made from pure asbestos rov ing, in single strand form. Style 202--A pure wick made from asbestos rov ing by twisting together several strands. Style 4199--A single strand wick made of pure asbestos. Style 4202--A pure wick made from several strands of asbestos twisted together. Johns-Manville Asbestos Twisted Rope Packing Furnished SA" diameter and up, in 10, 25 and 50-lb* reels Johns-Manville Asbestos Twisted Rope is made in four standard styles: Style 196 -- Canadax -- a commercially pure twisted rope made up around an asbestos core. Style 4196--A plain twisted asbestos rope for ordinary service. Style 200--A pure rope made by twisting several strands of asbestos roving around an asbestos core. Style 4200--A pure rope made from several strands of asbestos twisted together around an asbestos core. Johns-Manville Asbestos Braided Rope Packing Furnished in 10, 25 and 50-lb, reels Johns-Manville Canadax Braided Rope Packing, Round Style No. 566, Square Style No.; 787.; Made by braiding a commercially pure asbestos jacket over a pure asbestos twisted rope core. Made an(^ larger.- Sizes }4' to % inclusive have one jacket; % and over, two jackets. to %" inclusive have one jacket; %" and over, two. jackets. Johns-Manville Solid Braided Rope Packing, Round Style No. 702, Square Style No. 733.- Made of commercially pure asbestos yarn, braided into jackets, one over the other, in sizes an<3 over. Johns -'Manville Pure Braided Rope Packing. Round Style No. 857, Square Style No. 869. Made by braiding a pure asbestos jacket over a pure asbestos twisted rope core. Made and larger. Sizes Johns - Manville Pure Solid Braided Rope Packing, Round Style No. 788, Square Style No. 873. Made of pure asbestos yarn, braided into jackets, one over the other, in sizes %" and larger. Johns-Manville Asbestos Cord Furnished in and ldb. balls, 5 and 10-lb. spools, 25 and 50-lb. reels Fire and acid resisting Asbestos Cord, with strong, hard twisted strands. Especially valuable in glass and chemical works, and for suspending metals, retorts and crucibles in contact with fire or heat, Also used as a string packing on small valves. Sizes: Mu" to in diameter. 73 CRMC-003437 Johns-Manville Service to Railroads Johns-Manville Slip-Type Expander Ring HE Johns-Manville Slip-Type Ex- The Johns-Manville Slip-Type Expander Tpander Ring is recognized as one of Ring exerts, through its broad, band-like the most valuable achievements in steel jacket, a uniform pressure on the the air brake field, during recent years, packing, prevents it from dropping away This device has solved one of the,many from the cylinder wall and increases the problems which have .arisen incident to life and efficiency of the leather. ' perfecting the proper functioning of . the In regard to wear, it is practically ever- air brake. 7 . . . ... lasting and with ordinary care in handling It is carefully' constructed of the best will outlast other; component parts of the cold rolled steel and English spring wire brake equipment. ' and its superiority over the ol&style, round : There are, at the present time, over one expander ring is apparent at a glance. The million of these rings in service on all round ring can act.at only one point---the . classes of- equipment including locomo- heel of the cup,.providing no support what- tives, tenders, passenger and freight cars, ever for the lip of . the cup which accord- and the device is included m the A.R.A. ingly drops away from the cylinder wall, rules for labor and material in inter- The result of the concentration of pressure change. . at the heel is rapid deterioration of the cup. Prices on application. Cross-section of brake cylinder showing action of Johns-Manville Slip-Type Expander Ring as compared with old style ring. 74 CRMC-003438 I Johns-Manville Service to Railroads Johns-Manville Power Reverse Gear i Piston Packing OR a long Ftime the prop er packing of factory and will outlast them all, even under the power reverse most severe condi gear pistons pre tions. sented a serious The Johns-Man problem. There ville Power Re were two types of verse Gear Piston packing in general Packing Set com use: one a soft prises two Style packing; the other, No. 82 Moulded metal rings. Both Packing Cups to of these methods of gether with . two packing gave good s er v i c e immedi ately after being Joh.ns-ManviHe Power Reverse Gear Piston. Packing as installed .> Johns- Manville Slip Type Expan der Rings. , installed. ! However,: the soft packing The Style No. .82 Cup is produced es required too frequent replacement and pecially for power reverse gear service and the metal;! rings . had the: fault Common' is moulded of asbestos cloth and a com to alb ' metallic and semi-metallic ' pack pound which- makes' it non-porous and ings;' that is, they sdon - caused suffi cient wear on the cylinder wall to necessi tate,reboringv;:';" '"7 The development of the johns-Manville Moulded Cup-Method solved the power re verse gear packing problem. This type of packing, produced to meet the require ments of a service too severe for cast iron equally efficient undet air or steam pres sure. " ' The expander': ring is of the well known slip type which is standard for air brake cylinders, as described oh; page 74. This packing set is produced in a num ber of sizes and styles to suit all types and sizes of power reverse gear' cylinders. We welcome the opportunity of offer orthe numerous types of soft packing used ing our engineering service on power re for this purpose, has proven entirely satis verse gear packing problems. SIZES OF POWER REVERSE GEAR PACKING CUPS i 7i/ta M'3 int a - < rc CRMC-003439 . . 1/ * - u . &\ Johns-Manville Service to Railroads Johns-Manville Mallet Locomotive Packing Style .No. 49 .Style No. 35'.... Drawings showing the .alteration of the-old type of: joint, at left, to the;., new type, at right, furnished on request.. Style No. 49 Style No. 35 ACKING :for Mallet locomotives r- Style No. 35 has been developed to meet Pmeets possibly the hardest service the demand for better service and de, encountered i:: railroad work, and creased maintenance expense. Both the is, of necessity, a special typ.e. . . ^ v .u 'i- i v- ' Style No.: 49 is- in use otia majority of P^kmg and its method of application are railroads throughout. the United States the result o exhaustive tests plus years of and has been adopted as standard on a experience in the manufacture of packing number: of large systems because of the suitable for the extremely severe condi- superior service and economy it affords. tions on Mallet locomotives. Style No. 49 and Style No. 35 are furnished for both American and Baldwin Mallet Locomotives. Style No. 49 is also used in the expansion joints on high pressure steam, receiver and exhaust pipes. At all of our offices there are detailed drawings giving all information necessary for the proper application and maintenance of these materials. Blueprints of these draw ings and prices of packing will be gladly sent on request. 76 CRMC-003440 Johns-Maiwille Service to Railroads Johns -Manville Special Combination Air Pump Packing Air End Style No. 55 Steam End Style No. 15 OR the safe and efficient operation of F a locomotive, compressed air is not only highly important and necessary The construction of each individual set that is intended for the air end is different from that intended for the steam end and but also, most vital. Compressed air cathne packings for the air ends, and steam only be produced through the expenditure ends are packed respectively in separate of that valuable agent--steahi. Obviously, cartons, each carton marked for the end of then^, the packing used on locomotive air the pump for which it is intended. pumps on both steam and air ends of the rods should be the most efficient available. To this end, realizing full well that the best , results would be obtained by treating the air and steam ends;as two entirely differ ent packing problems and not' attempting The packing for the'air end is a combi nation of asbestos yarn and copper wire formed into rings which are thoroughly ' lubricated, sures and and which will withstand pres temperatures incident to this service without becoming hard and brittle. to make one style of'packing serve for two purposes, we .have developed Johns-Man-.. The packing for the. steam end is made ville Special Combination Air Pump Pack of asbestos fabric thoroughly, lubricated, ing---designed to' meet the most severe formed, cut and pressed to proper size and conditions .encountered in , this service. is admirably adapted to steam end service. LIST OF SIZES Style No. for Air End 1055 1155 1255 1355 2155 1255 1555 1655 1755 Style No. for Steam end 1015 1115 1215 1315 2115 1215 1515 1615 1715 ......... ......... .... .... ......... ................................. For ......... ......... ......... ..................................For 6-inch Westinghouse Air Pump 8-inch Westinghouse Air Pump 81^-inch Westinghouse Air Pump 91^-inch Westinghouse Air Pump 11-inch Westinghouse Air Pump Nos. 1 and 2 New York Air Pump No. 5 New York Air Pump No. 6 New York Air Pump (Prices on application) 78 CRMC-003442 Johns-Manville Service to Railroads Johns-Manville Moulded Air Pump Packing Johns-Manville Keystone Air Pump Packing OR packing the rods on the steam Fand air ends of air pumps. OR packing the rods on the steam and Fair ends of Westinghouse and New York Air Pumps. Each individual set of Johns-Man- Each individual set of Johns-Manville ville Moulded Air Pump Packing consists Keystone Air Pump Packing consists of a of several convex and concave rings, the pair of Johns-Manville Moulded Concave two end rings of the set being shaped to and Convex Rings on each end of which is fit the packing gland and the bottom Of placed a No. 10 Jewett Ring, bevelled to the stuffing box, respectively. fit the bottom of. the stuffing box and the The rings used, in this type of packing packing gland. are made of asbestos fibre and a suitable The Johns-Manville Special Moulded binder. 'This mixture is cured and mould- : Rings are made of asbestos and a suitable ed to the proper sizes and shapes, steel binding material-which, when cured and moulds being used. pressed to shape and size in steel molds, Our experience in making this material has enabled us to develop an air pump packing, which, is yery 'dense and yet re silient. The method of assembling the sets---i. e., convex and concave rings--in sures a tight fit against the rod and also against the inside of the stuffing box. make a hard and resilient ring with great density. They are built to resist high pres sures and Severeservice, The moulded Jewett Rings on each end of the set are made of asbestos yarn thor oughly lubricated, braided to. proper size and pressed into steel molds of exact shape and size. These-rings are softer than Johns-Manville Moulded Air Pump the Special rings and not only conform Packing is especially adapted to conditions readily to the shape of the stuffing box where there is considerable lubrication. and packing gland but provide for proper lubrication. LIST OF SIZES LIST OF SIZES Style No. 404--For 6-inch Westinghouse Air Pump 400--For 8-inch Westinghouse Air Pump 440--For 854-inch Westinghouse Air Pump 544--For 954-inch Westinghouse Air Pump 4444--For 1054-inch Westinghouse Air Pump 440--For 11-inch Westinghouse Air Pump 168--For Nos. 1 and 2 New York Air Pump 268--For No. 5 New York Air Pump 368--For No. 6 New York Air Pump ______________________ Prices r;n Style No. 300--For 700--For 800--For 600--For 2100--For 800--For 900--For 1000--For 1100--For 6-inch Westinghouse Air Pump 8-inch Westinghouse Air Pump 854-inch Westinghouse Air Pump 954-inch Westinghouse Air Pump 1054-inch Westinghouse Air Pump 11-inch Westinghouse Air Pump Nos. 1 and 2 New York Air Pump No. 5 New York Air Pump No. 6 New York Air Pump Prices im a|>f>//i:tini>ii 79 CRMC-003443 Johns-Manville Service to Railroads Westinghouse and New York Air Pumps Cross section of typical stuffing box, identifying the dimensions given in the table below: DIMENSIONS OF STUFFING BOXES AND SCHEDULE OF PACKINGS . . ..WESTINGHOUSE PUMPS NEW. YORK PUMPS . SIZE' OF PUMP - d7 .8":, 834"-, 1.0 >2" ,11" No, 1 No.,2 No. 3 No. 4 No: 5 No. 6 , g.,, 834" -934" 11" A- :nr B O mu his" D im: ln4i E. -W V F. , ........ V... Hr' No. of Stuffing Boxes per Pump ` 2 - 2 Depth of Pack'g m" r/r 13,'' 2?*" 24c" 1.34" mk" 16 " 'Hr - '32 " .. he" 4V 2 12&' m* 2" 2>V' 134" ;21^" "if" 7 J, " 4 I-3-;:" IK" 134" lK" l.M" 2*16" 2" 2" 2" ' 134" .134". 134" 134" 1-ik." w< 1%" i??6r Hie' 'hr W %" hV' 34c" nr 2 4 " ;4 '' 4i2K2" . T'To'"' 1M5e/ w lV|V' nr - l Vo" l?s" l?'s" 2" ' 2!4" 2vr ur 134" 134" 11-16 " vur 1%"- im" 1 'Hr W %" ;'W .nr. 9'3/2,,". .>32., . ?'l6" 4 V. 4''. 4" 2 I'Sfc' 1 25^'" v-nr i.H" iw 2?v 134" 1236" w 7 .V >32 4' 1%" nr nr 23-f6" 2?-16"- 1 nr .1)2'' wr l2^" 'Hr j3r6" nr Hr 2 134" 2 o Keaisarge No. 15... . 4 4 4 4 4 44 4 4 ' ' 4: 4 "4' ' 4 4 4 4 PQ Combination 15-55 ......... 4.. 4 4 4 4 44 4 . 4 : .4'.. 4 - 4 4 4 4 4 w Keystone .. . 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 c 44 4 4 4 44 4 4 4 4 4 4 4 4 4 P3 Moulded . .. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Kearsarge No. 15... . (A Combination No. 15 & Steam End c3 Combination z No. 55 Air 4) w Keystone ... Moulded . . . 475 1015 1055 300 450 404 775 1115 1155 700 750 400 875 1215 1255 800 550 440 675 1315 1355 600 650 544 2175 2115 2155 2100 2150 4444 875 975 1215 1515 1255 800 550 440 1555 900 950 168 975 1515 1555 900 950 168 975 1515 1555 900 950 168 975 1515 1555 900 950 168 1075 1615 1655 1000 1050 268 1175 1715 1755 1100 1150 368 775 1115 1155 700 750 400 875 1215 1255 800 550 440 675 875 1315 1215 1355 600 650 544 1255 800 550 440 80 CRMC-003444 Johns -Manville Service to Railroads Johns-Manville Kearsarge Locomotive Throttle Packing Johns-Manville Universal Locomotive Throttle Packing Style No. 15 Style No. 32 OHNS - MANVILLE Style No. 15 Johns-Manville Style No. 32 Universal J Kearsarge Locomotive Throttle Pack Locomotive Throttle Packing is especially ing is the same as Style No. 150 Kear designed and adapted for high pressure, sarge Rod Packing, as described on Pagehigh temperature service, a statement 66,' except that it does,not have the rubber' which can be confirmed by an examination expansion back, which,is usually found in of the throttle packing test records of a high pressure packing. number of railroads. V This packing is made of.asbestos fabric,; formed, cut and'tnpulded to proper 'sike. ; Since the advent of the larger locomo All rings are thoroughly lubricatedi: Be tives and also where superheated steam is cause of -the Johns-Manvilie method.: of . encountered, this particular packing has -manufacturing and folding the fabric arid met the most severe requirements, giving lubricating it, the. packing is more resili the maximum length of life. Th fact, ent and durable than other rod packings, ' it is possible with this particular type of .and is exclusively used on a great many packing to have one set remain in service of the leading railroads. from shopping to shopping of engine. It is especially efficient where engines are This packing is made from the best pooled, this being possibly the most dif heat-resisting materials and therefore does ficult situation to handle with any other not become hard in the stuffing-box. type of throttle packing. It is especially efficient where there is considerable condensation, a condition that is very difficult to handle satisfac torily with other types of throttle packing. Furnished in sets to fill the stuffing box exactly and when placing orders for this packing care should be taken to see that Made in sets to fit stuffing-box accord the exact diameter of the rod, the inside ing to exact diameter of rod, inside dia diameter and depth of stuffing box are meter and depth of stuffing-box, as given. given. 81 CRMC-003445 Johns-Manville Service to Railroads Johns-Manville Pump Packing Recommendations Use JOHNS-MANVILLE SEA RINGS for all Rods and Outside Packed Plungers. They are the BEST PACKING for the following rea sons: 1. They save pouer, because they are absolutely auto matic in action and the pressure of the packing on the rod is proportional to the pressure through the stuffing box. For this reason, the packing grips the rod only when there is a tendency to leakage and in proportion to the tendency to leakage. 2. They provide Packing Standardization--the elimina tion of various types of packing for different condi tions, because they are constructed of such materi als and so designed as to be the best packing obtain able for nearly all conditions. 3. They last longer than other packings because they are designed to operate automatically and are subject to pressure and wear only when necessary to pre vent leakage. The materials used are the best ob tainable. For the BEST RESULTS pack pumps as follows: ~~~ea B--Sea 0___5ea p [ Except where rod or plunger is under 54" Rings I diameter or space between rod and stuffing box RinBSf *s less than ?$", in which cases use Mogul Riii ns I Twisted No. 193, Braided No. 222. E--Universal Piston -- Coil No. 33, Spiral No. 34, Ring No. 35. F--Pump Valves No. 206. Packings that may be used but which are dependent upon gland pressure--the best of their class: A--Kearsarge--Ring No. 150, Spiral No. 166.* B--Kearsarge--Ring No. 150, Spiral No. 166.* C--Duplex--Coil No. 371, Ring No. 372, Spiral No. 373.* D--Duplex--Coil No. 371, Ring No. 372, Spiral No. 373.* * Except where space between rod and stuffing box is less than -Is", in which case use: Mogul Coil, Twisted, 193; Braided, 222. F--Johns-Manville Rubber Pump Valves. NOTE: For special conditions such as the pumping of chemicals, etc., consult nearest Johns-Manville office. Inside Packed Type of Pump. 82 Vertical Outside Packed Type of Pump. CRMC-003446 Johns-Manville Service to Railroads Johns -Manville Service Sheet Packing Style No. 60 OR packing parallel surfaces of Fflanges against steam (superheated or saturated), air, water, ammonia, oil and various acidulated and alkaline or other chemical solutions. Johns-Manville Service No. 60 is a sheet designed to give satisfactory service under practically any conditions where a sheet would be used. It has given and ivill give satisfactory service where other sheet packings have failed. The proper combination of Asbestos and bonding materials thoroughly mixed and felted together under enormous pres sure has produced a sheet that is pliable, resilient, adaptable to all: general work, and which does not deteriorate with age. This obviates the; necessity of stock ing several sheets for different conditions, .... which not only reduces waste-and loss due joints, wears, ionger and can be used to deterioration but also eliminates the ' use of a wrong sheet for a; certain service, a sheet graphited on one side only are bet- Scrap, consisting; of center and: corner ter than those cut from an ungraphited pieces, may be saved and used at some - sheet, or, a sheet graphited on both sides, future time, thus greatly-reducing- loss because one, side of: the gasket will stick to due to waste. ; v - " the flange and the other side will come It is so dense and yet so resilient'that it -loose. This keeps the gasket in shape when may be used in thicknesses one-half as repairs are being made so it may be used : great as sheets of rubber 6r other materi- again, seating itself in the same place as als. when the: joint was originally made; and Taking into consideration the density, the sheet is also much easier to handle, resiliency and light weight of Service Sheet, it is more economical to use than Furnished, in standard sheets 54" x 63" .rubber and many other types of sheet and 54" x 126" and in thicknesses of Yu", packing sold at lower per-pound prices. V<52" and also made and % 2" Surface finish--One instead of both sides thick. 3/-.2" and 1U-" thicknesses also of the sheet is graphited. Gaskets cut from furnished in sheets 108" x 126". SERVICE SHEET PACKING WEIGHS APPROXIMATELY: Per square yard .......................................................................... Per square foot ............................................................................ Per square inch .......................................................................... ; " thick 5,4 lbs. lbs. .0041 lbs. : thick 2.7 lbs. .3 lbs. .002 lbs. " thick 1.4 lbs. .15 lbs. .001 lbs. 83 CRMC-003447 Johns-Manville Service to Railroads Johns-Manville Seigelite Sheet Packing Style No, 711 A PPROVED by Underwriters' LaboraAV tories, Inc., for use against hazard ous liquids. For packing flanges or joints against gasoline, benzine, oil, greases, hot or cold water and air. A fibrous material that re sists the action of any of the above fluids, because it contains no rubber or rubber substitutes that are soluble in oil or gaso line. It has a very high tensile strength and when immersed in water or other fluids becomes extremely tough, resemb ling rawhide. It is more desirable than rubber or rub ber cloth insertion sheets for hydraulic service, on account of its strength. It is sold by the square, yard, is com paratively low in price and can be used with greater economy and efficiency than /`black oil proof" rubber sheet;/`red rub ber sheet"; : and C. I: (cloth insertion) sheet/'. The face of Seigelite sheet is ruled off with black lines into 1-iiich squares to facilitate cutting to any desired exact size without measurement. In. general> Jqhns-Manyille Seigelite is Seigelite Sheet Packing contains np rubber or similar materials. It assures better and more economical service fop many purposes. recommended for: making joints on pipe flanges, gasoline, pumps, and plumbing specialties; used extensively by power .plants, mills and factories, auto repair shops, automobile manufacturers, gasengine manufacturers, the motor-boat trade, steam-fitters and plumbers. SIZES, WEIGHTS AND LIST PRICES Thickness Width Length .01 inch ................................ Approximately48inches 25 or 50-yard rolls inch............................................. Approximately48inches 25 or 50-yard rolls .02 inch......................................... Approximately 48 inches 25 or 50-yard rolls '32 inch............................................. Approximately48inches 25 or 50-yard rolls lie inch............................................. Approximately48inches 25 or 50-yard rolls 532 inch.......................................... Sheets only, 36" x approximately 48" 5 s inch.......................................... Sheets only, 36" x approximately 48" 3ffi inch.......................................... Sheets only, 36" x approximately 48" 5 4 inch.......................................... Sheets only, 36" x approximately 48" 'ifi inch.......................................... Sheets only, 36" x approximately 48" Approximate Weight per Sq. Yd. 8 oz. 13 oz. lib. 1.7 lbs. 3.5 lbs. 5.1 ]bs. 7.0 lbs. 10,5 lbs. 14.0 lbs. 17.5 lbs. List Price per Sq. Yd. $0.85 1.05 1.35 1.90 4.50 6.80 9.20 13.50 18.20 22.60 NOTE--The above weights are only approximate, because the weight of this material changes, depending upon the quantity 0/ moisture in the atmosphere. After a period of dampness it will weigh more than when dry. 84 CRMC-003448 Johns-Manville Service to Railroads Johns'Manville Kearsarge Asbesto-Metallic Sheet Packing Style No. 100 enerally used where G surfaces are somewhat rough or uneven and where a sheet of a soft nature is there fore required. This packing is constructed of tightly twisted asbestos yarn, spun with brass wire to give additional strength, woven into Asbesto - Metallic J M KEARSARGE ASBESTO-METAILIC ^ PACKING . STYLE 5 100 "< \ _S cloth and impregnated with Johns - Manville Heat-Resisting Compound. Furnished in rolls 40" wide, about 250 lbs. each, in Yi-i" and 3 io" thickness. Can be furnished graphited on one or both sides, if desired. Johns-Manville Mobilene Sheet Packing Style No. 102 For packing gas and gasoline J- and impregnated with a special engine parts;' While Johns-Mam MOBlLENE compound to withstand the high ville Service Sheet Packing is our recommendation for. gas' engines . and garage service, Mobilene, a; SHEET PACKING temperatures incident to . this service. It has red compound, on one side, so that the packing will pioneer gas -engine ' packing* is stick to the flange when joint is still, frequently; demanded for broken, and graphite on the other packing cylinder-head joints and various to allow joint to be easily taken part. parts of gas and gasoline engines. This packing is made of asbestos fabric of great Furnished in rolls 40" wide, 250 lbs. strength, interwoven with fine brass wire each; u. and ''l c thick. Johns-Manville Liberty Red Rubber Sheet Packing Style No. 107, without wire Style No. 108, wire-inserted For medium or low pressure steam and hydraulic service. Manufactured from a special heat-resisting rubber compound of the highest quality, is comparatively light in weight, and will not deteriorate rapidly, Furnished plain or with wire insertion, in rolls 36" wide and weighing about 200 to 250 lbs. each; Ym" and Vs" thick. 85 CRMC-003449 Johns-Manville Service to Railroads Johns-Manville Kearsarge Standard Asbesto -Metallic Boiler Manhole, Handhole and Tube Plate Gaskets Better and longer service is ob tained from Kearsarge AsbestoMetailic Gaskets because of the greater strength of the unbroken round shoulder presented to the pressure OjR packing manhole and handhole The edges of the folds are on the inside of Fplates of boilers. Made of Asbesto- the gasket. Metallic fabric treated with a heat-re sisting compound, and folded into severalKearsarge Gaskets may be used over plies or thicknesses to proper size and shape. Furnished in oval form to fit plate for which they are intended. The gaskets again if properly applied. On this account and because of their light weight, they are most economical gaskets to use. are made so that an unbroken rounded Furnished in Style No. 116 for man shoulder comes 'on the outside of the ; holes, No. 117 for handholes, and No. 119 gasket which is presented to the pressure. for tube plates.. . Johns-Manville; Kearsarge Jointless Tube Plate Gaskets Style No, 118 For B. & W. and Heine, tube plates. The advantage in using jointless gas - Made, of Asbesto-Metallic fabric treated; kets for tube plate work is that there is no with heat -.resisting compound and folded, -tape joint to interfere with perfect seat-' into several plies or thicknesses to, proper . ing, so necessary when gaskets with a size and shape. very narrow flange are used. Johns - Manville Kearsarge Jointless Tube Plate Gaskets, Style No. 118, are made seamless, without a joint, from As besto-Metallic yarn, woven into hose or tubular form and properly folded. These gaskets are light in weight, very strong and treated with the same highheat resisting compound used in the man ufacture of Johns - Manville Kearsarge Standard Gaskets. Directions for application of Johns-Manville Kearsarge Manhole and Handhole Gaskets Best Tesults are obtained by placing a gasket on the manhole or handhole plate, then rubbing as much dry flaked graphite as possible on the exposed surface. The plate is then put into place. Before removing, the plate and boiler shell should be marked so that it can be replaced in exactly the same position. If this method is followed, the gasket always seats in the same place. The graphite prevents the gasket from sticking to the boiler shell, while the ungraphited side next to the manhole or handhole plate makes gasket adhere to plate when withdrawn. 86 CRMC-003450 Johns-Manville Service to Railroads Johns 'Manville Kearsarge Asbesto'Metallic Gasketing Tape OR making odd or ir Fregular shaped gas kets to pack joints against steam, air, water, ammonia and various acid ulated, alkaline, and other chemical solutions. Made of Asbesto - Metallic yarn, woven into fabric and treated with a high-heat resisting resilient cement. This material is gener ally used when a softer gasketing than JohnsManville Service Sheet Packing is required, on ac count of rough surfaces to be packed. Furnished in widths *4" and greater, and in thick ness 1/iG", Vs", 3/i6 and 14". Put up in 5 and 10 lb. rolls. Cannot be made in widths less than 1V/. APPROXIMATE WEIGHTS PER 25 FEET OF KEARSARGE TAPE, STYLE NO. 120 Width 1 " 1 l- , . iy2. -. " 2" : s" Thick ................. ................... lit .................. ................... .................. 2U " ,............. a:a:i .........-.3*8 ;.............. 334' .................. ......... .. ................. ....................434 . s:. ......... ............. ..................5 " ............... . -y Thick . 1,4 ...................... 2Y2 ........................3^4 .................. . .5 ----- .............................................. ------ ............... ....6'4 ...,............ .. .:...............7N ........................83.4 .;................10 Thick Johns -Manville Kearsarge Asbesto 'Metallic Tubular Gasketing To make manhole and handhole -gaskets in the case' of the doors of sterilizers, etc. . for boilers in bases of emergency, or Kearsarge Asbesto ^Metallic Tubular wherevera gasket with a round cross-sec Gasketing is packed in boxes weighing ap tion is .required, as in the case of grooved proximately 5 lbs. or boxes weighing ap flanges. proximately 10 lbs., the number of I2V2- Made by rolling the same Asbesto-Me- foot lengths per box depending upon the tallic fabric used in the manufacture of size of gasketing. Tape and lead are Kearsarge Standard. Gaskets into coils of furnished with gasketing. round section with a hol low center. This gas keting is primarily an emergency packing, but Approximate Weights of 12^-foot lengths. is used quite extensively for making odd or irre gular-shaped gaskets, or for packing joints where grooves are provided for the packing to rest in, as Style No. 124 Siae of Gasketing. Inch i/ " ?4 Approx. Weight 1 Pounds 1*8 2'/ 3% 87 CRMC-003451 Johns-Manville Service to Railroads Johns-Manville Service and Seigelite Gaskets HERE gaskets cut and ready for Wapplication are desired, we shall be pleased to quote on application, on sizes or sketches submitted. We are prepared to cut and furnish gaskets from any of our sheet packings. Inquiries should be accompanied with complete dimensions or sketches. Service and Seigelite are adapted to practically any conditions and we advise using gaskets cut from either of We recommend the ring type gasket. It makes a tighter, better and more economical joint than the full these materials whenever possible. cut gasket and avoids fussing with bolt holes, etc. Service Gaskets Style No. 61 Johns-Manville Service Gaskets No. 61 may be used for any variety of conditions, are cut from Johns-Manville Service Standard in thicknesses of *^4", and Sheet No. 60, described on page 83, and 3ig". Ring Flange Joint Gaskets Style No. 61 FOR. STANDARD FLANGES * Size: . Pipe. Inches O-tside D:sm., Inches List Price, Each 3/4 . 1 2YS $0.06 2-G .09 2 .12 l;-2 . 2" ' 2^ 3 354 A 454 . 5; 61 7 8' : 9. 10 12 14' 15 m 4;S 5fi 6n 6? 8 7.; . 754 8s y 10 -- 11 1-2*4 133* 16: 17-4 19 .15 ; .19 .28 .32 . .44 .46 . .46 .55. .62 .80 .90 1.18 ; 1.19 1.76 1.88 2.14 15 20-4 2.42 18 215g 2.2S 20 23` g 2.68 22 26 3.02 24 28*4 3.49 26 30*5 4.00 28 32-'4 4.54 30 34s g 4.70 FOR EXTRA HEAVY FLANGES ''Size Pipe. Inches Outside Diam.. Inches List Price, Each 23/4 $0.11 lG 354 .14 154 2. 37/s 4Vs . .20 .24 - 254 3 554 .30 57/s .42 355 Wz ,50 4. - .754 .52 ; .. 4*4 734 .63 5 - 854 .75 6 .m .97 7 11 1.13. 8 1254 1.26 9 13 1.43 10 14*4 1.62 12 16*4 2.22 14 1954 3.00 15 20 N 3.10 16 2154 3.61 18 2354 4.00 20 25*4 4.50 22 2734 4.90 24 303/8 5.76 NOTE:--The sizes given above, up to ar.d including 12 inch, are the nominal outside diameters of the pipe. Be sure that your flanges the nominal inside diameters of the pipe. Sizes above 12 inch are are standard and check with the above when ordering. Seigelite Gaskets Style No. 712 Seigelite Gaskets No. 712 are cut from 84. Furnished in thicknesses of .01", Seigelite Sheet No. 711, described on page \ *02", Vvz'f */icw- 88 CRMC-003452 Johns-Manville Service to Railroads Johns-Manville Water Gauge Gaskets HE insistent demands for a satisfac We can also furnish water gauge gaskets tory water gauge gasket induced us cut from Johns-Manville Millboard when to make a study of this problem. so desired, this material also making a It was found that the principal diffi highly efficient gasket. culty was to obtain a packing material - The pads for the back of the gauge are which would most effectively compensate cut from Johns-Manville Millboard to the for the difference in expansion between, same outside dimensions as the front the glass and the metal of the gauge. Tests. gaskets. developed the fact that; our Service sheet :packing met the requirements most suc cessfully and we accordingly proceeded with, the manufacture: of these gaskets. Thousands of them have been placed in service and found to meet the require The sizes shown in the table below are for the Reflex type of water gauge. We can also supply gaskets and pads for all other types of gauges. Gaskets and pads furnished in thick ments in every detail. They carry with nesses of I'ss" and 11 o". them our full recommendation. Prices on application. 89 CRMC-003453 Johns-Manville Service to Railroads Johns -Manville Rubber Pump Valves Johns-Manville Cold Water Pump Valves, Style No. 416--A medium hard valve for cold water, fresh, salt or alkaline. Johns-Manville Condenser Valves, Style No. 420--A soft, red condenser valve for lake, marine, and other severe con denser conditions. Johns-Manville Hot Water Pump Valves, Style No. 424--A hard valve for hot water, oily and alkaline solutions. Will stand temperatures up to 250'' F. though hard and dense, they possess the desirable quality of resiliency which makes them suitable for low-pressure as well as high-pressure conditions. Johns-Manville Top Head and Bottom Head Gaskets for Air Pumps Johns -Manville Pump Valves Service Style No. 61 : Molded from a specially prepared 'grade of Asbestos Compound stock under tre mendous pressure and,at a high temper ature. ; Style No. 206 Pump Valves will satis factorily meet almost any condition en countered in pump work. Therefore, their use eliminates the necessity of using many valves of various, densities for dif ferent conditions. Will not quick'.v de teriorate when kept in stock. The asbestos fibre and binding ingredi ents used in the construction of these valves make them so tough that thev are practically unbreakable, and they wul not crack or chip off. Exceptional economy is afforded by the use of Style No. 206 valves on account of their life as com pared with rubber and other valves. Al Johns-Manville .Top Head and Bottom Head Gaskets are cut from material suit able for this class of service. Prices depend upon the size of pump for. which the gaskets are intended to be used, either New York or Westinghousen Johns-Manville Union Washers For packing "Standard" and "Crane" unions. These washers are designed to meet the demand for a satisfactory pack ing for pipe unions and are especially adapted for service in steam, hot water, ammonia and gas pipes. They are made of Johns-Manville Service Sheet. Furnished Vic." or Vs" thick. When ordering Union Washers, specify whether "Standard," "Crane Standard C," or "Crane" are wanted. For "Standard" ................ Style No. 139 For "Crane"...................... Style No. 140 For "Crane Standard C" Style No. 140-C 90 CRMC-003454 Johns-Manville Car Insulation i 91 CRMC-003455 Johns -Manville Service to Railroads Johns -Manville Steel Passenger Car Insulation HEN steel passenger Wequipment was first de signed to take the place of wooden cars, several problems of design were encountered at the very outset. Could this type1 of equipment be satisfactorily heated : iit the winter ? - Could it, on- the other hand, be made- at- all; com fortable in the; summer? Would it not be a- veritable metallic sounding board, magnifying the clatter of every crossing and the grinding of every brake-shoe? One of the first materials sub mitted to the railroads and car builders, to solve these problems, was Johns-Manville 3-ply Sala mander Keystone Hair Insulator. This material when properly ap plied to the inside of the outside steel plates and the outside of the inside steel finish, does keep cars warm in winter and cool in sum mer, besides acting as an excel lent sound-deadener. Applied to 92 underframes, it prevents the sound of rumbling wheels, cross ing switches, and other noises from being transmitted to the in terior of the car,. It also prevents condensation from forming and settling on the side framing, as well as oh the upper and lower decks. . This insulation consists of three layers of chemically treated cattle hair fastened be tween layers of building and as bestos papers, with an outside layer of muslin which allows the material to be glued as well as clipped to the steel plates. Details of application of 3-ply Salamander Keystone Hair In sulator to steel baggage car. CRMC-003456 Johns-Manville Service to Railroads Johns-Manville Steel Passenger Car Insulation (Continued) Johns-Manville Salamander is one of the most efficient insulating materials that have been tested. This high insulation efficiency exists not only at the time of installation but continues throughout years of service, as Johns-Manville Sala mander Steel Passenger Car Insulation does not rot, pack down or otherwise de teriorate. Its application presents no difficulties whatever. It can be flanged around win dow posts, braces, carlines, purlins, up rights and any irregularities in sides, ends or roof framing, and can be curved to the radius of the decks. Salamander Insulation is furnished in ' standard bales 3' and 4' wide, contain ing, 200 square feet per bale. Also fur nished cut to size when so desired. :: All car builders are familiar with Johns- Manville insulating 'materials; and rail road companies have but to place the fol: lowing in their specifications,, to have the material correctly used: - Specification for Application of Johns- Manville Salamander Steel Passenger Car Insulation "Cars to be insulated throughout, in cluding sides, ends, upper and lower decks and underframes, with %" thickness of 3ply Salamander Keystone Hair Insulator, to be securely glued and fastened in place as shown on Railroad Company's draw ings, so as to prevent same from being dislodged." 93 Half section of Steel Car showing application of Johns-Manville Insulation CRMC-003457 Johns-Manville Service to Railroads Johns -Manville Ceilinite for Steel Passenger Car Insulation OHNS-MANVILLE Ceilinite is As- J bestos Roll Fire Felt, as described in detail on page 45, reinforced on the back with asbestos cloth. It is used for insulating steel passenger cars, between the inner and outer shells, for fireproofing electrical apparatus such as switch boxes, etc., or for any condition where a strong, flexible, fireproof felt is required. Furnished in rolls 36 inches wide, 100 feet long. A practically indestructible car in sulation; it retains its high initial efficiency and is unaffected, by vibration or other conditions of service THICKNESSES AND WEIGHTS OF CEILINITE Thickness :( Weight per Sq. Ft. Weight per 100 Sq. Ft. s'......... V'- v............ ................ v...... ........................ 1 1 , lb. I7* lh. .....................62 lb. ...................125 Ib. . . ...................187 - Ib. 94 Half Section of Steel Passenger Car showing application of Johns-Manville Ceilinite Fireproof Insulation CRMC-003458 Johns-Manville Service to Railroads Johns 'Manville Carinsul for Steel Passenger Car Insulation it I A sample of Carinsul showing construction. Carinsul is a felted cattle hair insulation, with a burlap center, backed on either side with a special asbestos covering. It is a panel form of insulation and is recom- mended for use back of the letterboard, as its rigidity permits its use without any guard or protection against raising and lowering of windows. Furnished in %" and thicknesses, in sheets 36" x 72" or 40" x 72", or cut to dimensions required. Johns-Manville Nycinsul for Steel Passenger Car Insulation A sample of Nycinsul showing construction. Nycinsul is similar in construction to Carinsul, but is not quite so rigid. It is recommended for use where a material of greater stiffness than Salamander, as described on page 92, is desired. It has been used successfully by a number of railroads as well as on earlier Pullman equipment, Furnished in %" and thicknesses, in sheets 36" x 72" or 48" x 72", or cut to dimensions required. 95 CRMC-003459 Johns-Manville Service to Railroads Method of Applying Johns -Manville Insulation to Steel Cars By Electric Spot Welding HE simplest and least expensive Tmethod of applying insulation to steel cars is that shown in the illus These methods are typical and may be used in connection with the application of the Johns-Manville Insulations recom tration herewith. This is accomplishmedended for steel passenger equipment as by spot welding wires to the steel frame, described in detail in this section. impaling the insulation thereon, using either clips or tin roofing caps over the wires and peening the ends of the wires over these caps. Another method of fastening is to use channels, angles, etc. It should be kept in mind in all designs, however, that it is es sential that insulation be fastened, in addition to the mechanical means by glueing to the steel sheets. This can be ac complished by the use of thick red freight car paint, which also acts as a preservative to the steel. ^7o Suit--4- /Yofo /2," tA/cA (TeSt/rifa 7~/}y Sketch showing spacing of spot welded wires 7? &UFA 7V S7Z27 M/PT \S7Z7Z 'S/ZTY'T / 'V/'4S/Vr/f'SJ.ZtfJ}* K \7<7 xsrssz &/&ST. Mae, cvraw s/sts, 7*<? G/y&Y, c>r// *------------ 96 CRMC-003460 Johns-Manville Service to Railroads Johns-Manville Insulation for Locomotive Cab Roofs HE reason for insulating locomotive purpose our Salamander Insulation, which Tcab roofs is to remedy the extreme conditions of heat and cold under is the same material that is used for the insulation of the majority of railway pass which the engine crew in the uninsulatendger cars in service in the United States cab must work. We recommend for this and Canada. Specifications for Application In applying insulation, first size it. as well as steel plate, with liberal application of thick red freight car paint. Wires are to be spot welded to steel roof plate as shown, on 12" to 15" centers. annealed wire may be used. Salamander Insulation is furnished in bales 36" and 48" wide, containing 200 square feet. 97 CRMC-003461 Johns -Manville Service to Railroads Transportation of Perishables EFRIGERATOR cars are impor Johns-Manville Hairinsul and Standard R tant in the life of the people because Hair Felt are the oldest known refrigera ' they are used principally to carry tor car insulations and are used exten the bulk of the nation's perishable foosdively on modern equipment. stuffs. They are important to the railways because they are factors in the production of revenue. It is insulation that makes the refrigera tor car possible. Hairinsul Refrigerator Car Insulation The ideal insulation for refrigerator cars is Hairinsul, which consists of long cattle hair, chemically cleaned and free from oils or other organic foreign matter. The hair is felted and placed between layers of waterproof paper, carefully stitched. Hairinsul is furnished in two thick nesses, namely %" and and is covered with three different weights of paper as required -- 80, 90 and 110 pounds per thousand square feet. The Hair Felt and paper are stitched together with a good quality thread, the stitches not more than 2" nor less than 1" in length and the rows of stitches are not less than 4" nor more than 6" apart. This material is furnished in rolls, in widths up to 108" and of practically any length. It possesses all the qualities that make the ideal insulator, first, because it can be applied to refrigerator cars in one width from side sill to side plate and extending from side door around the end of car to side door on the opposite side, and second, it can be made in widths and 98 CRMC-003462 Johns-Maiwille Service to Railroads Hairinsul Refrigerator Car Insulation (Continued) lengths to accommodate the dimensions of the roof structure. This elimination of joints means that it is practically applied in blanket form, and the calculation of heat conduction at any point of the car superstructure will always be the same. There is no other material that has the same insulation efficiency, combined with the everlasting feature of the hair itself. It can be applied en masse as shown for typical wall and roof sections for U. S. R. A. refrigerator cars, or applied against blind lining and inside and outside sheath ing. It has been used on practically all of the refrigerator cars built, and tests have indicated its superior qualities over any other form of insulation. A 99 CRMC-003463 Johns-Manville Service to Railroads Johns-Manville Standard Hair Felt Refrigerator Car Insulation OHNS-MANVILLE Standard Hair J Felt is made of cattle hair, carefully se lected and chemically cleaned. An im proved process is used in the manufac ture, resulting in a perfectly combined felt which is not subject to disintegration. It is widely used for refrigerator car insula tion, ranking next to Hairinsul for this work. The illustration shows the applica tion of Standard Hair Felt in the recom mended thicknesses. Standard Hair Felt is also used for the insulation of tank cars, as described on pages 101 and 102, for lining refrigerators and for insulating both hot and cold water pipes. LIST PRICERS AND APPROXIMATE WEIGHTS ; Thickness Price Per Sq. Ft. Weight-Per Sq.Ft. Weight Per Bale op. CJ) 'MS Ye, inch.; 4 ounces.. . 75 pounds ' ' K " . . ; -.08. 6 . " `... ......" '. .... .10 ...9 - " ...'.170 1 " . . .......... .12 . v IK " : ............ .18 2 " . . ................ 24 12 18 " 24 ..,225. . . ..337- ____ 450 ": Refrigerator Car Insulation Other Johns-Manville Refrigerator Car Materials REFERITE--Used for waterproofing of floor insulation. ASPHALT SATURATED FABRIC-- Used inside of outside sheathing and out side of lining, and as waterproofing fabric at floor line. ROSIN-SIZED SHEATHING--Used for lining floors and walls. ASBESTOS SILL COVERING--A brine-proof and acid-proof material used as sill protection in refrigerator, freight or stock cars. No. 50 ASBESTOS WATERPROOF ING FELT--Used with 14 lb. Asbestos Felt and Referite as floor membrane. 100 CRMC-003464 Johns-Manville Service to Railroads Johns-Manville Tank Car Insulation NSULATED tank cars are constantly I coming into more common use for the transportation of gasoline and other volatile commodities. One reason for this is that both shippers and carriers have become aware of the ex plosion and fire hazard created by hand ling these products in the ordinary tank car which is not equipped with any means of maintaining an even temperature with in the tank and offers no resistance to ex ternal heat being conducted through the tank shell and vaporizing the liquid car ried. The second reason for using insulated tank cars is to avoid the enormous evapor- INSULATION FOR CLASS IV TANK CARS . Insulation to be secured with No. 9 B. W, G. Wire. Wire on 18" centers for .Regal, 2.4" foi^Hair Felt. Note wiring on end of tank. Same method is used on dome. Stagger all joints. End view of insulated tank car ready for steel jacket. 101 2'PLY #G*U. - 'srtet f*jKTc Showing details of built-up insulation. CRMC-003465 Johns-Manville Service to Railroads JohnS'Manville Tank Car Insulation (Continued) ation losses which must occur in bare or improperly insulated tanks. Tank cars are divided into classes ac cording to date of construction, kind of construction, or service for which they are to be used. These classifications are shown in the "Standard Specifications for Tank Cars, Revised 1919, Effective Feb ruary 1st, 1920, American Railroad Asso ciation, Section III, Mechanical." Class IV covers tank cars for the transportation of volatile inflammable products whose vapor pressure at a temperature of 100 de grees F. exceeds 10 pounds per square inch, built after May 1, 1917. The insulation for Class IV Tank Cars consists bf two courses of 1" Standard Hair Felt and three courses of 2-ply Regal Roofing Felt. The insulation is applied as shown oh the \ preceding page. This method of insulation is in general use and has .been successfully, applied on a large percentage of the insulated tank cars built by. the various car builders. "We .are: prepared; .to- furnish complete engineering information on this subject upon request. We can also supply any desired information on the insulation of Class V Tank Cars, which are described as --"Insulated tank cars of special con struction, built after January 1st, 1918, for the transportation of liquid products whose properties are such as to involve danger of loss of life in the event of any leakage or rupture of the tank." Liquid products of this description whose ship ment has been authorized are -- chlorine and sulphur dioxide. Another tank car insulation problem which we have studied thoroughly is the transportation of such products as hot tar and asphalt. This is a matter entirely dif ferent from the insulation of cars carrying unheated^ materials such as gasoline. No specifications or data for the insulation of hot tank cars will be given in this catalog as each problem is handled separately, the method of insulation depending on several varying factors, such as loading temperature, temperature to be maintained, etc. Complete information will be furnished, upon request, to cover tank cars of this type. 102 CRMC-003466 Johns -Manville Asbesto -Metallic Friction Blocks and 103 CR^C-003467 HinfcSltm. Johns'Manville Service to Railroads Johns-Manville Asbesto-Metallic Friction Blocks applied to a brake band.: OR friction brakes as. used on hoists, F cranes, steam -shovels, /'dredges, and all Similar machinery, also for friction Metallic Blocks is always under perfect control, as far as the brakes or frictions are concerned. \ ; clutches: of Z all types,) or for any; brakingJohns-Manville Asbesto-Metallic Fric or power transmitting duty.where friction tion Blocks, will riot char, burn or cause material is used. Made: of selected: asbes fird, arid are practically unaffected by tos fibre, brass or .copper: wire,- and a spec moisture, heat or oily surfaces. ial binding compound,: densely Compacted The high friction co-efficient or grip together by vulcanizing, under enormous ping power of these blocks means that less pressure in metal; molds to. the exact form effort is necessary to control the machine required. on which they are applied than with Johns-Manville Asbesto-Metallic Fric many other braking materials. tion Blocks wear many times longer than The friction co-efficient of Johns-Man wood, leather and various other materials. ville Asbesto-Metallic Friction Blocks re Economy is effected not only on account mains more nearly constant than that of of their durability, but by minimizing other materials, under adverse conditions, shut-downs and reducing time and labor such as presence of oil, moisture, or exces made necessary by replacement of other sive heat due to heavy service. This re forms of braking materials. sults in uniform braking action at all These blocks grip smoothly and power times, without frequent adjustment. fully and release quickly, yet with the Due to its high heat-resisting proper minimum of shock to the machine to ties and resistance to wear, this material which they are applied. Machinery can be used in smaller areas of friction sur equipped with Johns-Manville Asbesto- face than other materials. 104 CRMC-003468 Johns-Manville Service to Railroads Forms in which Ashesto'Metallic Friction Blocks have been furnished secrnoN. cra? SECTION. agerior*. Description of Diagrams Blocks Nos. 1, 2, 4,16--Types frequently used for steam-shovels, dredges, stationary hoists, coal-dbck and mine-hoisting machinery. Blocks Nos. 8, 9. 10.--Types frequently used for multiple disc clutches and brakes. It is possible to mould Asbesto-Metallic Friction Blocks in a variety of forms for various services. 105 CRMC-003469 Johns-Manville Service to Railroads How and Where Johns-Manville AsbestoMetallic Friction Blocks May Be Used KETCHES are not intended to Sshow proper construction of clutch or brake mechanism, or of applica tion of blocks, but only to show in gen eral how and where our blocks may be used. Description of Diagrams A, B and C Diagram A.--Typical hoisting drum with brake and friction equipment. Lever throws friction block B, on revolving gear wheel, into contact with winding drum, transmitting power from gear to drum. When unwinding, drum is stopped by forcing iron band lined with brake blocks "A" against drum. Diagram A also shows asbestos blocks used as a facing on old wooden frictions. Facings are less expensive than complete V-shape blocks. Diagram B.--Shows principle of simple cone clutch with Johns-Manville blocks used as facing. Power is transmitted from power to transmission shaft by forcing cone and facing into contact with fly-wheel. Pedal or lever controls cone. Diagram C.--Shows elementary principles of mul tiple disc clutch or brake. Discs "A" are keyed to transmission shaft; discs "B" are held to fly-wheel by slots cut in edges which fit around bolts. Power is transmitted or absorbed by forcing discs "A" and "B" together by a spring. Pressure is released by forcing spring back from, discs with lever. . DIAGRAM A /ICISTING'DrUM EQUIPPED WITH' FRICTION AMD , . brake- BLOCKS . Typical Drum dkomna .. 'arptbpelrieedblacks are. DIAGRAM B ContactJvr/scc of flyWheel. 3 '`Tr/ctton cone block,or facing DIAGRAMMATIC SKETCH SHOWING PRINCIPLES OF SIMPLE COME CLUTCH DIAGRAM C SHOWING ELEMENTARY PARTS OF MULTIPLE. DISK FRICTION CLUTCH. CONSTRUCTION DETAIL OF DISK ON TRANSMISSION SHAFT.WITM FRICTION BLOCK-/V Sprtno & bald disks m mtasffer rwumitl*. Trsnsmisuon s' J..Jedkn End Ekration " Perspective. SOLID ASBCSTO METALLIC brake blocks A Tr. Section Elevation Perspective SOLID ASBESTO -METALLIC FRICTION BLOCKS b Transmission Shaft Disks keyed U transmission shaft Tljrrheel^oVs Sroores farflywhoet holts. 7r Section Elevation Perspectives. ASBESTO -METALLIC BLOCKS ON WOOD BLOCK; 106 ONE HALF OF FLY WHEEL DISK B CRMC-003470 Johns-Manville Service to Railroads Johns-Manville Non-Bum Asbestos Brake Band Lining for Industrial Use HERE machine de Wsign prevents the use of blocks, we recom mend Johns-Manville NonBurn Asbestos Brake Band Lining. Johns-Manville Non-Burn Brake Band Lining is made of asbestos fibre spun into yarn, reinforced with wires interwoven in each strand, and impregnated with a com pound which greatly increases its natural frict ional and wearing qualities. Most economical because it has high gripping power and great resistance to heat and foreign matter. Every piece of Non-Burn is stencilled with the name--look for it. List Prices per linear foot Furnished in two styles--Woven and Folded NOTE.---The following, list covers widths and thicknesses usually used for machinery purposes. Folded style, can be; furnished in all sizes listed. Woven style can be furnished in . all widths listed, to and including ?f'6" in thickness. Width1.''. '1. *...... IX"....................... : ,IK".. : XX"....... :i'.. .a ,.:2X"....:............. 1 ;2X".......................... :.2X"............................... / .3 .......... ; 3X"............................ .. 3X"......................... 3X".............................. 4 *................... ; . ; ' AX"......... -.................. ,'AX"............................. AX"............................... 5 "............................... SX"............................... SX".............................. SX"............................... 6 "............................... 6X"............................... 6X"............................... 6X"............................... 7 *............................... 7X"............................... 7X"............................... 7X"............................... 8 "............................... BX"............................... 8X"............................... BX"............................... ' Thick . Thick Thick $ .40 :'S U's iso'-- \ - .55 - :so .60 : *.60. ..-.65 '' .70 i-.70 - L-..7S 1 .;480. . .80 -.8S : " :.9o - `.90- . .95 1.00 ; 1.00 1.05 1.10 .1.10 , l.IS - T.20 1.20 . i:25 - I-JO ' ,3.25 '1.35 1.40 1.30 1.45 1.50 1.35 1.50 1.60 1.40 - .1.55 . -1.70 1.73 1.8S 1.97 1.80 1.94 : 2.08 1.86 2.03 2.19 1.92 2.11 2.29 2.02 2.21 2.40 2.12 2.31 2.50 2.21 2.40 2.60 2.27 2.49 2.71 2.64 2.90 3.15 2.72 3.03 3.34 2.79 3.09 3.40 2.86 3.18 3.49 2.97 3.31 3.65 3.08 3.44 3.80 3.IS 3.51 3.87 3.22 3.59 3.96 3.33 3.72 4.10 3.44 3-80 4.23 3.51 3.93 4.28 :"X" Thick $ .70 .80 ' .90 1.00 1.20 1:30 1.50 1.60 1.70 1.80 1.90 2.05 2.20 . 2.37 2.50 2.63 2.70 2.88 3.01 3.14 3.27 3.80 3.94 4.08 4.20 4.37 4.52 4.66 4.80 4.95 5.09 5.24 Thick $ .80 .94 1.11 1.26 1.41 1.56 1.72 1.87 2.02 2.16 2.21 2.31 2.50 2.71 2.92 3.07 3.22 3.36 3.52 3.67 3.82 4.44 4.61 4.78 4.95 5.12 5.28 5.46 5.63 5.60 5.96 6.13 X" X'f - ' . X": H" . Thick Thick Thick : Thick Thick $ .96 1.16 1.35 1.54 1.73 1.92 2.12 2.31 2.50 2.69 2.88 3.08 3.27 3.46 3.65 3.84 4.04 4.23 4.42 4.61 4.80 5.00 5.19 5.38 5.57 5.76 5.96 6.IS 6.34 6.53 6.72 6.92 ..$1.22' 1.48 1.73 1.99 2.24 2.50 2.76 3.013.27 3.52 3.78 4.04 ' 4.29 4.55 4.80 5.06 5.32 5.57 5.83 6.08 6.34 6.60 6.85 7.11 7.36 7.62 7.88 8.13 8.39 8.64 8.90 9.16 $1^48 1.80 2.12 2.44 2.75 ' 3.08 3.40 3.72 4.04 4.36 4.68 5.00 5.32 5.64 5.96 6.28 6.60 6.92 7.24 7.56 7.88 8.20 8.52 8.84 9.16 9.48 9.80 10.12 10.44 10.76 11.08 11.40 $1.73 $1.99 . 2:12 ' ; 2.44 ->2.50 . .2.88 2.88. . : 3.33 3.27 3.78 3:65 4.23 4.04 4.68 . .4:42 5.12 4.80 5.57 5.19 6.02 5.57 6.47 5.96 6.92 6.38 7.36 6.72 7.81 7.11 8.26 7.49 8.71 7.88 9.16 8.26 9.60 8.64 10.05 9.03 10.50 9.41 10.95 9.80 11.40 10.18 11.84 10.56 12.29 10.95 12.69 11.33 13.19 11.72 13.64 12.10 14.08 12.48 14.53 12.87 14.98 13.2S 15.43 13.64 15.88 . i" Thick $2.24 2.76 3.27 . 3:78 4.29 4.80 5.32 5.83 6.34 6.85 7.36 7.88 8.39 8.90 9.41 9.92 10.44 10.95 11.46 11.97 12.48 13.00 13.51 14.02 14.S3 15.04 15.56 16.07 16.58 17.09 17.60 18.12 (List Prices continued on next [nige.) 107 CRMC-003471 Johns-Manville Service to Railroads List Prices per linear foot (continued] Furnished, in two styles--Woven and Folded NOTE.--The following list covers widths and thicknesses usually used for machinery purposes. Folded style can be furnished in all sizes listed. Woven style can be furnished in all widths listed, to and including in thickness. Width A" . w Thick Thick W Thick X" Thick 'is" Thick H" Thick X" Thick A" Thick X" Thick A" Thick 1" Thick 9 9'A".. 9'A".. 9 y**.. 10 10 A".. lOX'-iox"-n UX'.. UK" UK' 12 12X"-. \1A" 12X*-13 13X"- 13X".13X"-14 '.. ............ .. 14X"14X",- .............. ... ... ... . . 14X",IS lSK". I5X"-:- ... ^ .. isx"-. 16 ".. . 16X":16X". - .*........... , , 16X"-. 17 . ; ____ I7X"-- . . . ... . * .V.., . 17X"-- *.*V. .**.. .i. 17X"-- 18 ' 18X"-- ' 18X"-18X"'. 19 ......... ; 19X"19X"-. 19X"-20 ", . 20X". ........................ 20X".- 20X"-. 21 ".. 23X"-- 21Xff.. 21X*'.22 22X"-- 22 y,r. 22X". 23 23X"-- 23X".- 23X".24 $3.58 $4.00 $4.43 $5.38 3-69 4.13 4.57 5.52 3.80 4.26 4.72 5.67 3.87 4.36 4.86 5.81 3-94 4.42 4.90 5.96 4.05 4.53 5.02 6.10 4.16 4.64 5.13 6.24 4.23 4.74 5.24 639 4.30 4.84 5.36 6.53 4.41 4.95 5.49 6.68 4.52 5.06 5.61 6.82 4.59 5.16 5.74 6.96 4.66 5.24 5.84 7.11 4.76 5.36 5.96 7.25 4.85 5.46 6.07 7.40 4.96 5.57 6.19 7.54 5.06 5.68 6.31 7.68 5.15 5.79 6.43 7.83 5.2S 5.89 6.54 7.97 5.35 6.00 6.66 8.12 5.45 6.11 6.78 8.26 : 5.55 6.22 6.90 8.40 5.64 6.-33 7.02 8.55 5.75 6.44 7.14 .8.69 .'5.85 , . . 6.56 7.26 8.84 5:94 . 6.66 . 7.37 .8.98 6.04 . 6:76 7.48 9.12 .. 6.14 . 6.87. 7.60 .9.27 .6.24 .. 6.97 . .7.71 9.41 .6,33 7.08 . 7,83 ... .9.56 6.43 7.19 7.95 9.70 6.52 . 7.29 8.08 ' 9.84 6.60 7.40 . 8.20 9.99 6:70 -. 7151 - 8.32 : 10.13 6.80 7.61 . 8.45 10.28 , 6;90 . 7.72 ... 8,55 . 10.42 : - 7.00 7,83 ., 8.67 10.56 . 7.08 7.93 8.76 10,71 ' 7.16' 8.03 . . 8.88 . .. 10,85 - 7.24 , 8:12 ' 9,01 11.00 7J2 8,23 9.13 11.14 . 7.41 8.33 , 9.25 11.28 7.51 8.43 936 11.43 7.60 8.53 9.46 11.57 7.68 8.64 9.60 11.72 7.77 8.74 9.72 11.86 ' 7.87 8.84 9.83 12.00 8:95 9.94 12.15 8.04 9.06 10.07 12.29 8.13 9.16 10.19 12.44 8.23 9.26 10.30 12.58 8.32 9.36 10.43 12.72 8.40 9.47 10.53 12.87 8.49 9.57 10.6S 13.01 8.59 9.68 10.77 13.16 8.68 8.76 8.85 9.78 9.88 9.99 10.88 11.00 11.12 1330 13.44 13.59 8.95 10.09 11.25 13.73 9.04 9.12 10.20 10.30 11.36 11.47 13.88 14.02 $630 $7.11 $9.41 $11.72 $14.02 $16.32 6.47 7.30 9.67 12.04 14.40 16.77 6.64 7.49 9.92 12.36 14.79 17.22 6.81 7.68 10.18 12.68 15.17 17.67 6.98 7.88 10.44 13.00 15.56 18.12 7.15 8.07 10.69 13.32 15.94 18.56 732 8.26 10.95 13.64 1632 19.01 7.48 8.45 11.20 13.96 16.71 19.46 7.65 8.64 11.46 14.28 17.09 19.91 7.83 8.84 11.72 14.60 17.48 20.36 8.00 9.03 11.97 14.92 17.86 20.80 8.16 9.22 12.23 IS .24 18.24 21.25 8.33 9.41 12.48 15.56 18.63 21.70 8.50 9.60 12.74 15.88 19.01 22.15 8.68 9.80 13.00 16.20 19.40 22.60 8.84 9.99 13.25 16.52 19.78 23.04 9.02 10.18 13 .SI 16.84 20.16 23.49 9.19 10.37 13.76 17.16 20.55 23.94 936 10.56 14.02 17.48 20.93 24.39 9.53 10.76 14.28 17.80 21.32 24.84 9.70 10.95 14.53 18.12 21.70 25.28 9.87 11.14 14.79 18.44 22.08 25.73 10.04 1133 15.04 18.76 22.47 26.18 10.21 11.52 15.30 19.08 22.85 26.63 1039 11.72 is:56 19.40 23.24 27.08 10.54 11.91 15-81 19.72 23.62 27.52 10.72 1230 . 16.07 . .20.04 24.00 27.97 10.90 12.29 16.32 2036 ,24.39 28.42 11.07 . 12.48 16.58 . 20.68. . 24.77. 28.87 11.24 12.68 16.84 .21.00 . 25.16 . 29.32 11.40 12.87 . 17.09 ;21.32 . -25.54 29.76 11.56 13.06 17.35 21.64 25.92 30.21 ,11.73 13.25 . 17.60 ' : 21.96 - 26.31 30.66- 11.90 13.44 17.86, 22.28 26.69- 31.11 12.07 '13.64 '.I8;i2 : 22.60 ' 27.08 31.56 .12.24 13.83 : 18.37 , 22.92 . , 27.46 32.00 12.40 14.02 18.63 22.24 - 27.84 32.45 12.57 - 14.21. .18.88 23.56 ' 28.23 32.90 ,12.74 . 14.40 ; .19.14 23.88 28.61 33.35 12.92 ,14.60 . 19.40 24.20 , 29.00 33.80 13.08 14.79 19:65 24.52 ' ' 29.38 34.24 13.25 14.98 19.91 . .24.84 - 29.76 34.69 13.44 15.17 20.16 25.16 30.15 35.14 13.60 1536 20.42 25.48 30.53 35.59 13.76 15.56 20.68 25.80 30.92 36.06 13.93 15.75 20.93 26.12 . 31.30 36.48 14.10 15.94 21.19 26.44 . 31.68 36.93 14.27 16.13 21.44 26.76 32.07 37.38 14.44 1632 21.70 27.08 32.45 37.83 14.60 16.52 21.96 27.40 32.84 38.28 14.78 16.71 22.21 27.72 33.22 38.72 14.95 16.90 22.47 28.04 33.60 39.17 15.12 17.09 22.72 28.36 33.99 39.62 15.28 17.28 22.98 28.68 34.37 40.07 15.46 17.48 23.24 29.00 34.76 40.52 15.62 17.67 23.49 2932 35.14 40.96 15.79 17.86 23.75 29.64 35.52 41.41 15.96 18.05 24.00 29.96 35.91 41.86 16.13 18.24 24.24 30.28 36.29 42.31 1630 18.44 24.52 30.60 36.68 42.76 16.47 18.63 24.77 30.92 37.06 43.20 S18.63 19.14 19.65 20.16 20.68 21.19 21.70 22.21 22.72 23.24 23.75 24.26 24.77 25.28 25.80 26.31 26.82 27.33 27.84 28.36 28.87 29.38 29.89 30.40 30:92 31.43 31.94 32.45 .32.96 33.48 . 33,99 .. 34.50 3S.01 35.52 35.78 36.55 37.06 37.57 38.08 ' 38.60 39.11 39.62 40.13 40.64 41.16 41.67 42.18 42.69 43.20 43.72 44.23 44.74 4S.25 45.76 46.28 46.79 47.30 47.81 46.32 48.84 49.35 108 CRMC-003472 Johns-Manville Steam Traps 109 CRMC-003473 Johns-Manville Service to Railroads The Johns'Manville Steam Trap WNERS, superintendents arid engi- The little device that guards the outlet of O neers give the purchase of large the coil or radiator, that should prevent - units for ' their power or- heating any steam from getting away before it has plants the most careful consideration, but given up its heat and yet allow all the importance of the smaller and less ex- water and air to get away and make room pensive power-plant unit is often over- for m0re steam, is an important factor of looked. _ the heating system. For example: The economical opera tion of a plant is largely dependent upon See table showing loss due to steam the efficiency of the steam trap used, leakage, page 252, Appendix. Continuous Perfect Operation of a trap necessarily depends upon the de sign of the trap and the arrangement of its parts. The Johns-Manville Trap has only three parts--the body, the discharge bushing, which screws into the outlet of the body, and the hollow, seamless copper ball, which is free to float and move in the body. Wear and maintenance cost naturally depend upon the number of trap parts-- especially those that move or those that are subject to corrosion. no CRMC-003474 Johns-Manville Service to Railroads ACTION OF THE JOHNS-MANVILLE TRAP When water first flows into the trap at X and begins flowing out of the discharge orifice Y, the ball (2) floats to and is held against the discharge bushing (3) by an unbalanced steam pressure. The discharge orifice is completely sealed until the water level (W) in the trap begins to rise, then the buoyant force of the water roJJs the ball upwards on the face of the discharge bushing (3), exposing either part or the entire area of the discharge orifice (Y)--depending upon the quantity of water entering the trap at X. When the quantity cf water entering the trap at X de creases. the level of the water drops to the point where the bait again partially or completely covers the discharge orifice Y being held tightly against the face of the bush ing (31 by the unbalanced steam pressure. In this way a water seal is provided between the steam in the top of the trap and the discharge orifice Y, eliminating all possibilty of steam leakage. The one moving part of the Johns-Manville Trap, the ball--replaces the valve, valve stem, levers, cotter pins, springs, thermostatic parts, buckets and all other similar parts used in the construction of other types of steam traps. The operation of the Johns-Manville Trap is positive and simple. It depends entirely upon the amount of water flowing to the trap. The ball is held against the flat surface of the discharge bushing by the pressure in the system. Water flowing into the trap acts as a force which raises or rolls the ball upward on the face of the discharge bushing and thus exposes part or all of the outlet ori fice. The ball rises and falls, according to the quantity of condensation coming to the trap, and the flow from the trap is regulated accordingly. . No Air Binding The Johns-Manville Trap will not-.air If a trap will not discharge air or .gas as bind" because air (heavier than steam. but ' well, as water, the air will accumulate in lighter than water) accumulates- OriV the; the trap and system unless vented by some surface: of the water,'which is a very`short supplementary means. The inability of distance above the trap outlet and is dis other types of steam traps to discharge charged with the water through small vor air ivith the water and without loss of steani tices that form between the surface of the is due to their construction and principle water and the outlet. We put a pet cock of operation requiring a thick water seal on"the cover of our trap, not as an air re over the outlet of the trap to prevent the lief, but because it is useful to show that loss of steam. Such a water seal effectually the trap is operating properly. prevents the discharge of air. No Steam Leakage is possible with the Johns - Manville Trap because there is always a thin water seal between the outlet and the steam. If the water-level drops too near the outlet the ball also floats lower, closes the outlet and effectively stops discharge of water or steam. ill CRMC-003475 Johns"Manville Service to Railroads The Johns-Manville Steam Trap on account of its simplicity of construc tion and operation, requires practically no attention. There are no adjustments to make--no valves to stick. Replacements or repairs seldom have to be made. In fact, there are only two parts -- the ball and dis charge bushing--that could wear. Operation is positive and continuous, hence any machine or system to which these traps are attached is always free of air and water. The Regular Models (made of cast iron) are suitable for all pressures. The Junior Models are made for pressures up to one hundred pounds per square inch. *------------------- A--------------------- ` i*-----------------------------------E------------------------------------ 1 See table for; dimensions indicated. Capacity and Dimensions The capacities . given for pipe ; sizes shown are average, not the ma.Yimz/ni-^as are frequently given in other capacity tables, Peak or emergency conditions fre quently require a trap to handle more water than when operating under normal conditions so a factor'of safety should be al lowed. The Johns-Manville Trap will take care of more water than any other trap of the same size. CAST IRON MODELS FOR ANY PRESSURE Trap No. Pipe Lbs. of Water Si2e, Ins. Per Hour A 2- A........................ 3- A......................... 4- A........................ 5- A........................ 6- A...................... # 1 1# 1# 2 700 1000 1700 3S00 6000 7? jo 8# 10# 12# 14# Dimensions in inches. (See diagram.) 8 CD E 6 TVs 8# 11# 13 2'A 3# 4# 5H 6# 3# 4# 5# 7# 8# 6# 8 10# 12# 14# Weight Lbs. 14# 23 47 85 126 List Price Each $27.00 35.00 40.00 70.00 95.00 112 CRMC-003476 Johns-Manville Service to Railroads The Johns-Manville Junior Trap A compact trap for low, medium or high pressure services. DEAL for small steam line drips, coils,': cover screws to the body instead of being I indirect stacks, radiators, cooking-, bolted. This makes it extremely compact, utensils, coffee-urns, plate-warmers, The Junior, too, consists of only a body steam-tables, sterilizers, ovens, kettles, rolling ball and -discharge bushing. Disglue-pots, steam-plates, laundrymachines, : charges continuously; will not leak.steam; dryers, dressers, calenders, etc., or wher- has no complicated parts and cannot airever condensation does not exceed 250 bind. pounds per hour.. . Johns-Manville Junior Steam Traps are The Johns-Manville Junior Trap is'tbie same in its principle of operation as the larger Johns-Manville Trap, the only difference being its size, the metal of which the body is made, and the fact that the equipped with bushings for low, medium , or high pressures. Neatly finished, made, of highest grade steam metal. Pressure ranges are 1-10 lbs.; 10-30 lbs.; 30-100 lbs.; see tabulation below. BRONZE JUNIOR MODELS FOR PRESSURES UP TO 100 POUNDS Trap with bushings (or Low Medium High pressures Pressure Range 1-10 lbs. 10-30 lbs. 30-100 lbs. Pipe Size Inches 54 Dimensions 4%" long JC 3ys" high Weight 23/8 lbs. List Price Each $10.00 113 CRMC-003477 Johns-Manville Service to Railroads The Johns -Manville Radiator Trap A |,AHE Johns-Manville Radiator Trap Noiseless--Nothing'to vibrate, rattle or I operates on exactly the same princi-. make any kind .of noise, as the ball is the pie as the; Johns-Manville Steam only moving part and is surrounded by a Trap. The only, part that moves is the cushion of water. ball--it discharges air, gas and water con- : No Steam Leakage--A thin but constant tinuously as they come to.it and without water seal always prevents steam leakage. loss of steam. The action of the Johns-Man- Non-Air Binding--Free discharge of air ville Radiator Trap is positive--that is, it is. and water permits radiators to heat up . operated directly by the water of condensa- rapidly. '' ; tion which must be discharged from the Capacity^Not affected by variation in radiator, and not indirectly by the tern- temperature, of water discharged. pej-ature of. the water to be discharged. Those qualities which make it superior, and so desirable to use with heating systerns are: Simplicity Nothing to get out of order, Finished Appearance--The shape and size make the Johns-Manville Trap an attractive t of the heating system. The owner, arc.h.iztect. , engineer and, operator will get full satisfaction because Durability--Nothing to wear -- repairs after installation perfect results are ob- and replacements minimized. tained without care or changes. Non-Adjustable -- Nothing to adjust-- therefore no after adjustments necessary and no chance of adjustments being tarnpered with. Steam-fitters and contractors will be relieved of all trouble after installation because of no after adjustments and a minimum of repairs and replacements. 114 CRMC-003478 Johns-Marrville Service to Railroads For pressures up to 10 pounds--either For use on cast iron radiators only, unless gravity or vacuum systems. Furnished in ordered special. For dimensions, see op bronze or bronze with plain nickel finish. posite page. LIST PRICES Standard Trap Angle Connections Type.. ..Vz" and Pressure Range Oto 10 pounds Straightway Type........... Yz and Va" Oto 10 pounds Corner Type...................... . .Yz" only Oto 10 (Right and left) pounds Pipe Size Approximate Inches Weight Finish List Price Each Yz" 2 lbs. 5 oz. bronze ................. $7.00 Yi" 2 lbs. 5 oz. nickel finish ... 7.50 3/a" 2 lbs. 7 oz. bronze 8.00 Yi" 2 lbs. 7 oz. nickel finish ... 8.50 Yz" 2 lbs. 3 oz. bronze ................. 8.00 Y2" 2 lbs. 3 oz. nickel finish ... 8.50 Y4" 2 lbs. 6 oz. bronze 9.00 3/4" 2 lbs. 6 oz. nickel finish ... 9.50 Yu" 2 lbs. 4 oz. bronze ................ 8.00 Yz' 2 lbs. 4 oz. nickel finish ... 8.50 How to specify a Johns -Manville Steam Trap LL steam traps required shall be A suitable for pressures at which they ""must operate, and must discharge bushing. The hollow copper ball is to act as a valve to regulate the discharge from the trap, and is to be free to revolve or ,air as well as water without the aid of sep- move in any direction, having no levers, arate air passages. All traps are to be of rods, weights or valves of any description thd iion-attached rolling ball type, consist- attached to it. The traps are to contain no ing of only three essential parts: body, thermostatic parts.. non-attached rolling ball and discharge How to specify a Johns'Manville Radiator Trap All radiator traps placed on the return side of the radiators shall have *4" connections and must discharge air as well as water without the aid of separate air passages. All traps shall be of the non-attached rolling ball type, consisting of only three essential parts, the body, non-attached rolling ball, and a union connec tion. The hollow copper ball which acts as a valve to regulate the discharge from the trap is to be the only moving part, is to act as a valve to regulate the discharge from the trap, and is to be free to revolve or move in any direction, having no levers, rods, weights or valves of any description attached to it. The radiator traps are to contain no thermostatic parts, No other valve will be accepted under this specification unless approved by the Architect in writing, NOTE If it is desired to specify Johns-Manville traps by their names, an additional paragraph should precede the other paragraphs on both steam and radiator trap specifications. This paragraph to read: "All traps shall be the Johns-Manville non-attached rolling ball type." 115 CRMC-003479 Johns-Manville Service to Railroads The Johns-Manville Volume Meter For the accurate measurement of boiler feed water, and other liquids HE notable features of this meter are Tits extreme accuracy, simplicity and durability. Constant accuracy and long life are se cured by the total elimination of fric tion between meter parts. The meter has no moving parts. It cannot wear out. Although origin ally designed for the measurement of boiler feed water its freedom from: movihg parts makes it ideally suited for : the measurernent of many liquids such as corrosive chemicals which .prohibit the use of submerged bearingsj valves or other m ec ha n.i c al parts. . . As the meter is a purely static device and measures in fixed volumes it is equally well suited to the metering of liquids of varying viscosities and densities. It will accurately meter the volume of practically any liquid that will flow freely through a pipe or conduit. The Johns-Manville Volume Meter con sists essentially of two tanks or compart ments of fixed volumetric capacity which are alternately filled and emptied. A counter or chart re corder indicates the number of times the compartments are filled and emptied, thereby furnishing a record of the quantity of liquid passed through the meter. The Johns-Man ville Volume Meter can be built for any . capacity from lab oratory size up to that required for measuring a city water supply. Its accuracy is practi cally 100%. In boiler plants : the meter is partic ularly adaptable for such services as the measurement of boiler feed water, make-up water, wastes from hot wells and blow-off tanks, or for the metering of condensate from power generating units. Additional information will be fur nished by any Johns-Manville Branch. 116 CRMC-003480 Johns-Man ville Asbestos Roofings 117 CRMC-003481 Johns'Mairville Service to Railroads Johns -Manville Asbestos Roofing A | ^HE quality of asbestos products de- The fibres extracted from the crushed 1 pends.; not only-upon , the experience, asbestos rock are graded by length and .? skill- and equipment of the manufac strength. For roofing fabrics we select turer, but also upon the quality of the raw that grade of fibres which gives uniform material. Since asbestos fibres vary, the ity of texture and the highest tensile correct grading and selection is absolutely strength. For built-up and ready-to-lay necessary. roofing these fibres are fabricated by spec- . ial machinery into strong compact felts, Controlling every step from mine to which in turn are thoroughly impregnated market, combining the facilities of the with natural asphalts. The felts are then miner with the expert knowledge of the cemented together with hot asphalt either manufacturer, Johns-Manville has excep on the roof (for built-up roofing) or at the tional opportunities for discriminating in factory (for ready-to-lay roofing). the selection of asbestos fibre for JohnsManville Asbestos Roofings. There is no roof built--flat, monitor, saw-tooth, or special design--to which This in itself is a definite manufacturing Johns-Manville Asbestos Roofing in one advantage. form or another cannot be applied. 118 CRMC-003482 Johns-Manville Service to Railroads Johns 'Manville Roof Registration And What It Means to the User ffMlIllliftm .A.I.'S nmisTEii mis nmmyo 'W1XXI OHOM12ST >//., f/., /f //S'*/,///y //'t /fry1'r/rrf/s*//'., />// //j'.s //-//// ,s?/'/ /"//f /.'*//'*/ ''`///'Y/ . ________ SyO"sYZ/tf."s///>'///............... .......................................... yiW/TJ sy/..____ - Z//yZs,,y rs/s/t// // ///YZ- ////</ Zf'Yf/rs/"/ JOHXS->rAXVSI/L>: Jxr.. Exccurivt offices.- fov vo&k CANAOI<\N J< ---Lf'yj'-y'S'g.a > 'r v ie sf *? -<ti; n-a . CO..LTt M A y x x. v g . > srti=->--.gs-g . A fac-simile reproduction of. the Johns-Manville Roof Registration blank. N addition to a formal written guaran I tee for "a, specified number, of years, which is the usual manner in which a accidents, abuses or unusual condition ex isting at the time. . In this way we assume the entire re roofing. ^manufacturer vouches for thesponsibility for the performance of , our service value of his material, Johns-Man materials and see-that every Johns-Man ville offers -a still broader protection; ville roof owner* obtains the full service through its plan of roof registration. from his roofing that we promised for it. Under this plan a Johns-Manville roof ing user registers his roofing with us, at the time of application, by filling in a reg istration blank as shown on this page and forwarding it to our nearest branch. This blank is recorded and placed in the hands of our roofing department which arranges for a periodical inspection of your roofing by a Johns-Manville representative. And this applies to every part of his roof ing because we believe it is our duty to see that Our materials in the flashings and gutters stand up as well as the surface of the roofing itself. By this policy of roof registration we translate the formal terms of our guaran tee into active service value to you. Be sure that when a Johns-Manville Roof is applied to your building a registra This means that we keep careful track tion blank is filled out and forwarded to of the roofing in service, and notify you of us so that you will obtain the benefits of the results of our inspection and of any this service. 119 CRMC-003483 Johns-Manville Service to Railroads Approval by the Underwriters HE attitude of insurance authorities and maintained under the direction of the Ttoward a building material is of spec- National Board of Fire Underwriters, the ial interest, both because of its effect official body representing all recognized on insurance rates, and because it serves fire insurance companies of the country, as a reliable index to the fire-resistant At these laboratories, roof coverings of properties of the material m question. e description are tested, examined For this reason the results of tests made and classified according to their resistance by Underwaters Laboratories, Inc., are of t0 fire. The tests made these roof_ particular importance to the prospective in ar most severe and exhaustive in_ buyer of any building material. cluding the radiant heat; burning brand The Underwriters' Laboratories are lo- and flame exposure tests described and cated at Chicago, 111., and are financed by illustrated on this and the following pages. FIG. 1--MAKING RADIANT HEAT TEST The temperature of the circular plate at the lowest point of the gas furnace is approximately 1200 degrees Fahrenheit. See page 124 for details of test. 120 CRMC-003484 Johns-Manville Service to Railroads FIG. 2--APPARATUS .USED IN MAKING STANDARD FIRE TESTS OF ROOF COVERINGS The cylindrical gas'furnace is. mounted on trunnions so it can be turned to any . . angle: at7.which: the':. roofing is tested.. The air duct is of sheet ;nietal and has a ; v-. ; L -. discharge opening 7 by 2$4 feet. FIG. 3--APPLYING SAMPLE ROOFING TO STANDARD DECKS FOR TESTS Experienced men are employed to do this work. A pile of completed decks is shown at the left. The motor and fan for securing the wind velocities are shown in the background. 121 CRMC-003485 Johns-Manville Service to Railroads Burning Brand Test SAMPLE SUBJECTED TO AIR CURRENTS OF 12 MILES PER HOUR Exposed Sidei; Unexposed Side. / SAMPLE SUBJECTED TO AIR CURRENTS OF 40 MILES PER; HOUR Exposed Side. Unexposed Side. Figure 4 Fig. 4--Photograph at top of page on left shows condition of Johns-Manville Asbestos Roofing after burning brand test; photograph on right shows under side of sheathing after same test. Wind velocity 12 miles per hour. Photograph at bottom on left shows condition of Johns-Manville Asbestos Roofing after burning brand test with wind velocity of 40 miles per hour; photograph on right shows under side of sheathing after same test. See page 125 for details of test. 122 CRMC-003486 Johns-Manville Service to Railroads Flame Exposure Test SAMPLE SUBJECTED TO AIR CURRENTS OF 12 MILES PER HOUR Exposed Side;.. Unexposed Side.. SAMPLE SUBJECTED TO AIR CURRENTS OF 40 MILES PER HOUR Exposed Side. Unexposed Side. Figure 5 Fig. 5--Photograph at top on left shows condition of Johns-Manville Asbestos Roofing after flame exposure test, subjected to air currents of 12 miles per hour; photograph on right shows under side of sheathing after test. Photograph at bottom, on left, shows condition of Jobns-Manville Asbestos Roofing after flame exposure test, subjected to air currents of 40 miles per hour; photograph on right shows under side of sheathing after completion of same test, See page 126 for details of test. 123 CRMC-003487 Johns-Manville Service to Railroads Radiant Heat Test SAMPLE SUBJECTED TO AIR CURRENTS OF 12 MILES PER HOUR The illustrations on the left show condition of sample subjected to air currents of 12 miles per hour. Exposed Side. Unexposed Side. SAMPLE SUBJECTED TO AIR CURRENTS OF 40 MILES PER HOUR The illustrations oh the; right show condition of ; sample subjected to air currents.; of 40 miles per hour.. ' Exposed Side. Unexposed Side. Figure 6 Fig. 6--The photographs above show the condition of the Johns-Manville As bestos Roofing and under side of sheathing after the radiant heat test was completed. In the radiant heat tests wind velocities of 12 miles per hour and 40 miles per hour are used to determine the effect upon the roofing material under examination. See page 125 for details of this test. Seldom does a roofing on an average building encounter such conditions as it is called upon to withstand under the search ing eyes of the impartial official investi gators at the Underwriters' Laboratories; so that any roofing which meets these rigid laboratory requirements and is clas sified to take the base rate of insurance, may be safely put on any building with a 124 CRMC-003488 Johns-Manville Service to Railroads Fig. 7--Flame Exposure Test Apparatus in Action. See pages 123 and 126 for details. knowledge that it is fire-safe to the high- est degree. Johns-Manville Asbestos Roofings are put through the tests described and are given either Glass "AT'br. "B" rating, according to the construction of the roof deck and the type of' roofing. Either Class "A" or Class "B" takes the base rate of insurance. 'v ; Radiant Heat Test To ; determirie ` how the ^ '.roofing:. will to simulate wiiid. A sample of_ roofing is stand up when;:\subjecte<L;fi^ shown undergoing such>:d. test in Fig. 1, heat from a nearby fire farinecf by\a breeze,- page 120. The resujts^M: this test are a radiant heat test,is made-on the roofing: shown in Fig. 6, page l:24tr ; while it is exposed,to varyihg air currents :iV Burning Brand Test To determine the fire resistance of a roofing when burning brands fall upon it, as is liable to happen to adjacent buildings when fire breaks out while a strong wind is blowing, each roofing examined at the Underwriters* Laboratories is sub- jected to the burning brand test. In performing this test the burning brand is made up of 1" by 1" maple strips formed into a grid, the strips being approximately *4" apart and held together by similar strips to which they are nailed, The brand is approximately one foot square and is ignited by placing it in a gas furnace. This furnace is heated by a grill of gas jets which form the bottom of the furnace chamber. The brand is supported above the jets and is exposed to the heat of the furnace until it is all aglow and completely covered with coals. The glowing brand is then lifted from the furnace and placed in 125 CRMC-003489 Johns-Manville Service to Railroads the proper position on the surface of the roofing sample. The brand is permitted to burn until entirely consumed or until the roof covering has failed by permitting the ignition of the deck boards on the un der side. One operator carefully notes the time of ignition and the spread of flames on the surface of the covering, also the rate at which the brand is consumed. An other operator observes the condition of the sample on the under side. Fig. 4, page 122, shows the condition of Johns-Manville Asbestos Roofing and the under side of sheathing after this test. Flame Exposure Test To observe the behavior of roofing un- fails and the deck boards are ignited. One der the action of flame playing directly operator observes the time of ignition of upon it as might occur on a building roof, the covering and the rate of spread of a direct flame contact test is made. flame over the surface while another oper- The apparatus used in subjecting sam- ator observes the under side of the deck pies of roof covering to direct flame con- and notes the time in which the deck tact is illustrated in Fig. 7, page 125. This boards take fire. The effects of such a test apparatus consists of a burner with an ori- on Johns-Manville Asbestos Roofing are fic.e 36 inches long and y2. inch wide from evidenced in Fig. 5, page 123. which a gas flame is emitted. The flame As a result of the extremely high fire passes over the surface of the sample di- resistance afforded by Johns-Manville rectly exposing an area about 36 inches: Asbestos Roofings under these tests they wide by 36 inches high,-;have been given highest ratings---Class - The'Sample is set in-place before the- "A" or "B," according to roof deck and apparatus and the burner, is ignited. The type of construction and take base rates of sample is thus exposed-until the covering insurance. Dock Freight Sheds of Michigan Central Railroad, at Detroit, Mich., showing application of Johns-Manville Asbestos Roofing. 126 CRMC-003490 r Johns'Manville Service to Railroads J M* ~i-Jd'' t? hii-USi RAILWAY EXCHANGE BUILDING, : ,ST. LOUIS, MO., Covered with Johns-Manville Asbestos Built - up Roofing. Mauran, Russell and Crowell, Architects, St. Louis. ! ?. - Johns-Manville Asbestos Roofings in different forms; for every type of service: Page Built-up Asbestos Roofing 128 Shingles, Asbestos (Rigid type) ........:. 167 Shingles, Asbestos, (slate , surfaced, flexible type) . 179 Ready-to-lay . Roofing, As bestos, smooth and slate surfaced ............................ . 141 Asbestos Protected Metal Roofing and Siding.... 159 Corrugated Roofing and Siding, Transite.............. 151 Ready-to-lay roofing, ragfelt, smooth and slate surfaced .............................. 183 127 CRMC-003491 Johns-Manville Service to Railroads Round House of the Central Railroad of New Jersey, Communipaw, N. J., showing Johns-Manville Asbestos Built-up Roofing and Johns- Manville Transite Asbestos Wood Smoke. Jacks. Johns -Manville Standard Asbestos Built-up Roofing OR fiat or pitched decks up to 6" to Realizing that a durable roofing must Fthe foot; Johns-Manville Standard be made of raw materials that are natiir- Asbestos Built-up Roofing can also ally durable, Johns-Manville uses Asbestos be.laid on pitches exceeding 6" to the foot felts and natural asphalts--two minerals where: suitable nailing is provided, 'intended by nature .for: permanent water As a roofing cannot-be better than the . and weather protection.- - materials of which it is made; .it is of-first Therefore, Johns-Manville Standard importance to know the nature and prop- Asbestos Built-up Roofing, composed of erties of the raw materials used to produce these two minerals--is different and natur- it. If such raw materials are inherently ally affords longer and more economical perishable or inflammable it would natur- service than roofings made of perishable ally follow that the finished roofing would materials, have the same limitations. Its Main Points of Difference and Superiority Are; It Is More Durable It will last indefinitely because it is made of rock. There is nothing in it to rot or dry out. Asbestos, of which it is made, is a mineral that is practically as old as life on earth; a mineral that has resisted the destructive forces of nature for centuries and is immune to rot and weather, 128 CRMC-003492 Johns-Manville Service to Railroads It is More Economical because it does not require painting, coat ing or surfacing of any kind after its in stallation. The reason it does not require this form of maintenance is that the asbes tos felts retain their asphalt impregnation and do not dry out. As compared to rag felt roofings, which do require such expen sive upkeep, the elimination of this item with Johns-Manville Standard Asbestos Built-up Roofing represents a considerable and increasing saving, particularly where the roof area is large and service condi tions severe enough to compel frequent maintenance of other roofings. Its Asbestos Felts are waterproofed and built up on the roof deck with refined natural asphalts, the conceded best of all roofing and waterproofing agents. No coal tar pitch is used in the manufacture or application of Johns-Manville Standard Asbestos Built- up Roofing. Our asphalts are carefully chosen and blended for longest life. We own no oil wells; we have no asphalt de posits to exploit; we buy only those ma terials that satisfactorily meet our high standards. Its Smooth Finished Surface means quicker and better drainage; for this construction the surfacing is likely quick and easy tracing of leaks due to be separated from the felt by the sun to abuse or accident to the roofing and cor- and carried away, by water, snow and ice, rection with the minimunf of time, labor leaving the perishable rag felts exposed to and expense. V^-the direct attack of sun and: weather.. As Its ! smooth surface . is particularly- they are not intended for such exposure' adapted to sawtooth, cdnstructipp. Where the surfacing must be quickly replaced or "a siag ot:gravel' surfacedv noofihg;:-is. used the felts may crack ana disintegrate. ' ` It is Reinforced at the Vital Points the -valleys and flashings, --^the; places bination of asbestos, special Sashing fabric where, practically -90% - of all roofings and Asbestile Gerpent,-applied according troubles occur;; The flashings 'are a: com- to Johns-Manville specifications. . It is Light in Weight weighing approximately 300 to 400 pounds less per square thaii gravel or slag surfaced roofings. Due to the durability of the materials used and the effectiveness of these specifi- cations Johns-Manville can afford to back up the performance of' its Asbestos Builtup Roofing, including the flashings, with Johns-Manville Responsibility, It is Approved by Underwriters' Laboratories, Inc. and given Class "A"or"B" rating, according to the roof construction. Either classification takes base rates of insurance. And you get the benefit of the JohnsManville plan of roof registration by which we see that you get proper service from our roofing. See page 119 for complete details of this plan of roof registration. You obtain the advantage of the pro- 129 CRMC-003493 Johns-Manville Service to Railroads gressive improvements which our engi neers develop from practical experience. They study each particular roof deck and plan its roofing to meet the requirements of the structure and the service demanded. Some of the details of application as shown in this section will be of interest to architects and engineers. Johns-Manville Insulated Roofing Where conditions of condensation or objectionable room temperatures from ex terior conditions are encountered, JohnsManville Insulated Asbestos Built - up Roofing will effectively eliminate a great percentage, if not all, of the trouble. Johns-Manville Insulated Roofing is a combination of our Standard Asbestos Built-up Roofing applied over an efficient, durable, insulating felt that reduces the heat and cold conductivity of the roof deck. This felt is known as Johns-Manville Roofinsul. The drawings on page 137 show some details of application of Johns-Man ville Insulated Roofing. Our engineers will be glad to make a survey of your con ditions and give you full recommendations without obligation on your part. Whether you have a mammoth indus trial building or a one story addition the same degree of satisfaction and service is assured and the same scrupulous attention given to the application of the job, as well as the advantages of registration. : 130 CRMC-003494 Johns-Manville Service to Railroads Specifications--Johns-Manville Standard Asbestos Built-up Roofing Over Wood Sheathing Underwriters' Laboratories, Inc. Class "A" On all wood roof decks as shown on plans apply JohnsManville Standard Asbestos Built-up Roofing as follows: Materials Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns - Manville Standard Asbestos Built - up Roofing Felt. Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb. Nails: To be 1/%" barbed nails and flat tin caps. Asphalt Cement: To be Johns-Manville As phalt Roofing Cement. Flashing material as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over wood sheathing as follows: Application of Materials 1. Lay sheets of the 60 lb. felt directly over the Start at low point of roof with a one-half width sheet sheathing. Lap the joints 3" and seal them with asphalt of the 14 lb. felt, then a full width sheet of the same cement. Nail these sheets along the lap with barbed felt laid flush with and entirely covering the one-half nails-driven through flat - tin caps, - spaced 6"' apart.' width sheet. Then lay full width sheets, setting the The 60 lb. felt shall be laid parallel to pitch of roof and turned up 2"'on all vertical surfaces, but not ce mented to vertical surfaces. , first so as to over-lap the one-half width starting sheet 2" and then exposing 15" of each succeeding sheet to the weather. Mop the entire surface between plies with the asphalt ' Over the 60 lb. felt,'Edging strips composed of"the, cement, heated to flow freely, and roll the felts closely Flashing Material shall be applied at eaves^ arid gable . behind the mop so that no missing of asphalt can pos over-hang,, extending.. 4" on roof, cemented and nailed, sibly take place. .and turned down over and .secured to fascia and pro Nail the back,edge, of, each, sheet with the barbed jected'.^" beyond .to. form a drip' edge. . V; nails driven through flat- tin caps spaced 9" apart; the >. 2.. Mop the entire surface of the .60 lb. felt with- .the : -. center line of hail heads to be approximately Yi" be asphalt cement,, heated,,to flow 'freely, and while th.e low back edge of sheet.'. ; -' cement is- hot, imbed,in it- sheets .ofv-the 14 lb. felt in 3. ` When the* ropfing is' othefwise complete, cover two-ply construction, the 14 lb, felt.to be run'at right, the entire surface with a mopping of the asphalt ce angles to the, 60- lb. felt, lapped 17'-.and turned.up 2" ment, to be applied hot, using approximately 25 lbs. on all-vertical-suffaces. v, to the square. (See detail on page 135.) Flashings Walls and all other elevations ^bove .roof sur- shall be composed of base flashings of Johns- fa.ce shall be.-, carried vertically at least 12" to; . Manville Asbestos Flashing material, approxi- provide for proper flashing. ' . A . mately 10^"; wide, cemented and nailed to ver- Roofing material shall ,be carried up on all tical surface. Such flashing shall be counter- vertical surfaces 2". All flashings, except those flashed with Johns-Manville'Asbestile System, around ventilators, stand-pipes, exhausts, etc., Preparation of Roof Surface The jollouing to he inserted in Carpenter s specifications: Sheathing boards shall be dry, well seasoned and of uniform thickness, laid closely--tongue and grooved sheathing preferred. Roof surface shall be graded to drain all water freely into gutters and down-spouts. Ends of all sheathing boards shall rest on and be properly secured with at least two nails to joists or purlins. If edges of sheathing boards are curled up, they shall be drawn down and properly secured to joists or purlins, eliminating all standing nail heads and other projections. All loose knots and other flaws shall be removed, and all holes prop erly filled or covered. All loose nails, chips and ether rubbish shall be removed and the deck made and maintained perfectly clean and free of all obstructions other than tools and appliances of roofer. All drainage connections shall be set to permit free flow of water. A 3" x 3" triangular wood strip shall be furnished and installed (wherever base flashings are to be used) in the angle formed by roof and vertical surface. All to be done by owner or contractor other than roofing contractor. 131 CRMC-003495 Johns-Manville Service to Railroads gres?' - Specifications--Johns-Manville Standard Asbestos Built-up Roofing Over Non-Combustible Roof Surfaces Underwriters' Laboratories, Inc. Class "A" On all non-combustible roof decks as shown on plans apply Johns-Manville Standard Asbestos Built-up Roofing as follows: Materials Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns-Manville Standard Asbestos Built-up Roofing Felt. Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb. Asphalt Concrete Primer: To be Johns-Man ville Asphalt Concrete Primer. Asphalt Cement: To be Johns-Manville As phalt Roofing Cement. Flashing materials as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over DRY con Crete or gypsum roof deck as follows: Application of Materials 1. Coat the concrete or gypsum with the cold primer, lb. felt, lapped 17" and turned up 2" on all vertical using approximately 1 gallon over concrete and 1 to 2 surfaces. gallons over gypsum per 100 square feet of roof sur Start at low point of roof with a one-half width sheet face to provide a proper bond between roof deck and of the .14 ,1b. felt; then a. full, width sheet of. the. same asphalt. Allow the. primer to dry. .felt laid flush with and entirely covering the one-half 2. Mop the entire Surface thus primed with the .width sheet. Then, lay full width sheets, setting the asphalt cement, heated to flow freely and while the first so as to over-lap the one-half width starting cement is hot; imbed in it sheets of the 60 lb. felt. sheet 2", and then exposing 15" of each succeeding Lap'the'joints 3" and seal them with.the hot asphalt, .sheet to the weather. .. ; cement. The 60 lb. felt shall be laid parallel to pitch; of Mop the entire surface between plies with the asphalt roof ahd.'.-tu'rh'e'd up 2" on all vertical surfaces, but hot cement, heated to. flow freely, and roll the felts closely cemented to;vertical -surfaces. behind .the mop . so that no missing of asphalt .can pos Over the 60 ,1b. felt/Edging strips composed of the sibly take-place. ' . Flashing vIdat'erial' shall.'.be applied'. at . eaves and gable over-hang-extending 4" on fOof, cemented and turned down over and secured to fascia and. projected'^" be ; !: 4. On gypsum- arid other, types of roof decks permit of nailing, the:`laps of the 60 -lb. felt and the edges of the 14 lb. felts shall be securely nailed to that back roof slab with cut nails driven through flat tin caps in ad yond'to form a drip' edge, .- . dition to mopping. '- ... 3. Mop the entire surface of the 6.0. :1b. felt with the 5. When the roofing is otherwise complete, cover hot .asphalt cement, and while the cement is hot,-imbed the entire surface with a mopping of the asphalt ce in it -.sheets, of the 14; lb. felt, in-,tw.o-ply construc ment, to be applied, hot', using'approximately 25 lbs. to tion, the: 14 lb. felt, to be .run. at right , angles to the 60 , the square, (See detail on page 135.) Flashings Walls and other elevations above roof surface shall ;be carried vertically at least .12" to provide for proper flashings. Roofing.material shall be carried up on vertical surfaces 2". All.flashings, except those around ventilators, stand-pipes, exhausts, etc., shall be composed of base flashings of Johns-Manville Asbestos Flashing material approximately 10*4" wide. Such flashings shall be counter-flashed with Johns-Manville Asbestile System, NOTE: On concrete surfaces maximum pitch upon which this roofing may be applied .without nailing is 3" to the foot except on short runs, as in sawtooth construction. If wood nailing strips are inserted in concrete, the pitch may be increased. Preparation of Roof Surface The folioicing to be inserted in Mason's specifications: Roof surface shall be graded properly to drain all water freely into gutters and down-spouts. Roof surface shall be finished smooth and hard, containing no depressions or projections and must be thoroughly set, air-dry and free from frost. All rubbish shall be removed and the deck made and maintained perfectly free of all ob structions other than tools and appliances of the roofer. All drainage connections shall be set to permit free flow of water. The angle formed by roof and vertical surface (wherever base flash ings are to be used) shall be rounded into proper cove. All to be done by owner or contractor other than roofing contractor. 132 CRMC-003496 Johns-Manville Service to Railroads Specifications--Johns-Manville Asbestos Built-up Roofing Over Wood Sheathing Underwriters' Laboratories, Inc. Class "B" On all wood decks as shown on plans apply JohnsManville Asbestos Built-up Roofing as follows: Materials Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns-Manville Standard Asbestos Built-up Roofing Felt. Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb. Nails: To be 7/q" barbed nails and flat tin caps. Asphalt Cement: To be Johns-Manville As phalt Roofing Cement. Flashing material as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over wood sheathing as follows: Application of Materials 1. Lay sheets of the 60 lb. felt directly over the sheathing. Lap the joints 3" and seal them with asphalt cement. Nail these sheets along the lap with barbed nails driven through fiat tin caps, spaced 6'' apart. The 60 lb. felt shall be laid parallel-to pitch of roof, and turned up 2" on all vertical surfaces, but not ce mented to vertical surfaces; Over the 60 lb. felt, Edging strip.s- composed of the Flashing Material shall be applied at eaves and gable ; oyer-hang, extending 4" on roof, cemented and nailed,. ' and turned, down over and secured''to fascia and. pro jected to form a .drip edge.- 2. Mop- the. entire, surface of the 60 lb. felt with the ;.asphalt cement, heated, to flow freely, and while the cement is hot, imbed imit sheets :of the 14 lb, felt in . single-ply construction; the. 14 -lb.: felt -*0 be run at. right angles to the 60 lbi felt; lapped -3" and; turned up-2"- on all vertical'surfaces. Start at low point of roof with a one-half width sheet of the 14 lb. felt, then a full width sheet of the same felt laid flush with and entirely covering the one-half width sheet. Then lay full width sheets, over-lapping the preceding ones 3",, with. 29" exposed to the weather. ; Mop the entire surface between plies with the asphalt cement, heated to flow freely, and roll the felts closely behind the mop so that no missing of asphalt can pos-. ,'sibly take place., Nail the backedge of each sheet with the-barbed nails driven through -fiat tin. caps spaced 9" apart; the, center line of nafi heads.'to be approximately 54" be low back edge of sheet. 3. When the roofing 'is . otherwise complete, cover the entire surface /with, a mopping of the asphalt cement, to be applied hot,., using approximately 25 lbs. to the square. (See detail on page 136.) Flashings , ;Walls and all other elevations above roof sur face. shall' be. carried vertically' at least 12" to provide for proper, flashing. Roofing material shall / be: carried up on- all vertical surfaces 2".All flashings, except those around ventilators, stand-pipes; exhausts, etc.; shall be composed: of' base flashings of JohnsManville Asbestos Flashing material, approxi mately 10^2" wide, cemented and. nailed to ver tical surface. Such flashing shall be counterflashed with Johns-Manville Asbestile System. Preparation of Roof Surface The following to be inserted in Carpenter's specifications: Sheathing boards shall be dry, well seasoned and of uniform thickness, laid closely--tongue and grooved sheathing preferred. Roof surface shall be graded to drain all water freely into gutters and down-spouts. Ends of all sheathing boards shall rest on and be properly secured with at least two nails to joists or purlins. If edges of sheathing boards are curled up, they shall be drawn down and properly secured to joists or purlins, eliminating all standing nail heads and other projections. All loose knots and other flaws shall be removed, and all holes prop erly filled or covered. All loose nails, chips and other rubbish shall be removed and the deck made and maintained perfectly clean and free of all obstructions other than tools and appliances of roofer. All drainage connections shall be set to permit free flow of water. A 3" x 3" triangular wood strip shall be furnished and installed (wherever base flashings are to be used) in the angle formed by roof and vertical surface. All to be done by owner or contractor other than roofing contractor. 133 CRMC-003497 Johns-Manville Service to Railroads Specifications--Johns-Manville Asbestos Built-up Roofing Over Non-Combustible Roof Surfaces Underwriters' Laboratories, Inc. Class "B" On all non-combustible roof decks as shown on plans apply Johns-Manville Asbestos Built-up Roofing as follows: Materials Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns-Manville Standard Asbestos Built-up Roofing Felt. Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb. Asphalt Concrete Primer: To be Johns-Man ville Asphalt Concrete Primer. Asphalt Cement: To be Johns-Manville As phalt Roofing Cement. Flashing materials as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over DRY con crete or gypsum roof deck as follows: Application of Materials 1. Coat the concrete or gypsum with the cold primer, tion, the 14 lb. felt to be run at right angles to the 60 using approximately 1 gallon over concrete and 1 to 2 lb. felt, lapped 3" and turned up 2" on all vertical gallons over gypsum per 100 square feet of roof sur-. . surfaces. .. . face to'provide a proper bond between roof deck and Start at low. point of roof with a one-half width sheet asphalt, Allow the primer to dry. of the 14 lb. felt; then a. full width sheet of the same . felt laid flush with and entirely covering the one-half 2.-..'-Mop : the . entire.;, surface . thus primed with '-the' asphalt cement, heated' to .flow, freely .and while the cement..is-.hot,, .imbed . in,.it .sheets, oi: the 60 lb. felt,, width sheet. Then lay full width sheets, overlapping the preceding ones 3", with 29" exposed to the weather. -Lap the .joints. 3" ..and .seal them with .the hot asphalt . Mop the entire surface betweemplies with the> asphalt cement.,. The 60.1b. felt shall beriaid parallel to pitch;of . cement, heated to flow freely, and roll the felts closely roof, an^: turned up. 2". p,n all vertical surfaces, but not behind the mop so that no missing of asphalt - can pos .cemented to vertical surfaces. ./ v sibly takeplace.; v .Over:.the 60 Ib^ felt,. Edging strips composed of theFlashing, Material shall be applied at. eaves and gable, over-hang^; extending;:^" ion roof, cemented, and .turned; down'over and secured to fascia and projected J4" be . 4. On gypsum and other types of roof decks that `permit o. nailing, the laps -of the 60 lb., felt and the back . edges of the 14 ,1b. .felts',shall be securely nailed to roof slab with cut nails , driven through flat tin caps in ad dition to. mopping. yond to form a drip' edge..- ; 5. When the roofing is otherwise complete, cover , ; 3/ Mop the entire- surface of'the 60 lb. felt with the the entire surface with a, .mopping, of the asphalt ce- hot; asphalt, .cement, ahd.while the .cement .is hot, imbed njent, to be applied hot, using, approximately '25 lbs. .to in it sheets of the 14 lb- felt, 'in single^-ply construc the square.' (See detail' on page 136.) Flashings Walls and other elevations above roof surface shall be carried vertically'at least 12" to provide for proper flashings. Roofing material shall be carried up on vertical surfaces 2". All flashings, except those around ventilators, stand-pipes, exhausts, etc., shall be composed of base flashings of Johns-Manville Asbestos Flashing material approximately 10*4" wide. Such flashings' shall ..be counter-flashed with Johns-Manville Asbestile. System, NOTE: On concrete surfaces maximum pitch upon which this roofing may be applied without nailing is 3" to the foot except on short runs, as in sawtooth construction. If wood nailing strips are inserted in concrete, the pitch may be increased. Preparation of Roof Surface The jolloiving to he inserted in Mason's specifications: Roof surface shall be graded properly to drain all water freely into gutters and down-spouts. Roof surface shall be finished smooth and hard, containing no depressions or projections and must be thoroughly set, air-dry and free from frost. All rubbish shall be removed and the deck made and maintained perfectly free of all ob structions other than tools and appliances of the roofer. All drainage connections shall be set to permit free flow of water. The angle formed by roof and vertical surface (wherever base flash ings are to be used) shall be rounded into proper cove. All to be done by owner or contractor other than roofing contractor 134 CRMC-003498 Johns"Manville Service to Railroads ddpi'np fa v. carried out an roe/* as sfioiun and turned doian airier /asera. Details' -of ^application. of Johns-Mahville Standard Asbestos. Built-up Roofing-- Underwriters' Laboratories Class "A" over wood sheathing: Drawing.. R-94-S ~'dpinp fa Pe carried out an reef as sfratan end fumed dawn overfascia Details of application of Johns-Manville Standard Asbestos Built-up Roofing--Under writers' Laboratories Class "A" over non-combustible roof surfaces: Drawing R-94-C 135 CRMC-003499 Johns-Manville Service to Railroads Details- of application of r Johns-Manville Asbestos Built-up RoofingUnderwriters'.Laboratories Class '`B" over wood sheathing: Drawing &-38 Details of application of Johns-Manville Asbestos Built-up Roofing--Underwriters' Laboratories Class "B" over non-combustible roof surfaces: Drawing R-39 136 CRMC-003500 Johns-Manville Service to Railroads Details'of application of Johns-Manville Roofinsul.(Va"- or XA" thick) in connection with JohnsManville Standard Asbestos Built-up Roofing---Path Method--Sheathing--Drawing; R-42 Details of application of Johns-Manville Roofinsul or z/2" thick) in connection with Johns- Manville Standard Asbestos Built-up Roofing--Path Method--Concrete--Drawing R-43 137 CRMC-003501 Johns-Manville Service to Railroads Coping to be set after- flashing is on place flashing to be ca.7~r-z.ed to within ? "of outside face of coaZZ ftt**lU- It ts advisable to have angle farm ed by watt and roofslab rounded inJ&. proper cove +iTt'C-'-*o-'n-c/. y. ..1v'" sa^osnjy\ Details of Johns-Manville Asbestile System of Flashing--Cap flashing carried up wall. and-a'crossVtOp under coping'to within 2" of outside face--Drawing F-l8. HOTS-rAl! - bricJz CofcOnereTe) surfaces to . be .printed with '.Jbhns-Ptanz/iZle Gsncrets Primer before mopping with fspliaZt RoafingOtment. -- 'plies' of Jbh.ns~`Ptani7zZle jSsbestos Roofing Felt, /4 lit., carr.ief over brzch'Zey and mopped solid '. Required length o ~^\ project.and. be left loose ; until base is iTtsZdlled. -Flashing to- exten f To zoithzTi Z" ' of outer' face oftuall. Details of Johns-Manville Flashing--Cap flashing carried through wall over brick key to within 2" of outside face--Drawing F-24. 138 CRMC-003502 Johns-Manville Service to Railroads ^Details of Johns-Manville Asbestile System of Flashing. ; (Concrete wall and concrete roof deck):--Drawing F-27. Details of Johns-Manville Built-up Gutter in wood sawtooth construction--Drawing G-20 139 CRMC-003503 Johns-Manville Service to Railroads 140 CRMC-003504 Johns-MaTiville Service to Railroads The durability, freedom from maintenance and fire resistance of Johns-Mariville Asbestos Roofings assure the best fire and weather protection, for railroad buildings at the least cost. Johns -Manville Asbestos Ready-to -Lay Roofings OHNS-MANVIU.K Asbestos Ready- f to-lay Roofings give years of positive protection- against firfe^and leather/ Q by, special machinery into strong compact felts, which in turn ard thoroughly impreg nated with natural/ asphalts of known a comparative basis--as to first cost plusvalue for durability.: ! repair cost -- Johns. - Manville - Asbestos .' Ready-today Roofings effect a ' saving which represents a splendid return on the investment.. That's why they are called the "cheapest-per-year". roofings. Their low upkeep is due to the unchang ing properties of the raw material, asbes tos, plus proper design and manufacture. These properties are not subject to var . And this asphalt impregnation does not dry out. It is held intact and protected in the body of the felt--actually sealed there because, unlike animal or vegetable fibres, asbestos fibres are non-tubular. They are immune to the capillary attraction set up by sun and weather, which draws off the asphaltic oils of roofings composed of tu bular animal or vegetable fibres. iation, nor are they dependent upon any coating or reinforcement which requires Made in different styles and weights to periodical renewal. It is because of what's meet different types of buildings and vary IN them--not ON them--that Johns- ing service conditions. Suitable for appli Manville Asbestos Ready-to-lay Roofings cation on engine houses, sheds, stations, give years of fire and weather protection tool houses, warehouses, shops, elevators to the buildings they cover. or on any type of building where a ready- Selected asbestos fibres are fabricated to-lay roofing is desired. Hi CRMC-003505 Johns-Manville Service to Railroads Flexstone Brand Asbestos Ready Roofings Smooth Surfaced Slate Surfaced Double Coated Flexstone slate surfaced roofing com bines the attractiveness of a colored sur MADE of heavy, tough felt of asbes tos fibres thoroughly impregnated face with the fire protection of asbestos. with natural asphalt and then Where a roofing must be ornamental as heavily coated on both sides with aspwhaelltl. as durable this type will meet every . Packed in one-square rolls which in requirement. clude completing materials and instruc It is made of the same asbestos fibres as tions for application. Shipping weight ap Flexstone Smooth Surfaced Roofing. The proximately 55 lbs. per square. crushed slate is imbedded in the asphalt Heavy coating while it is hot. The asphalt used is carefully chosen and blended and retains A rugged asbestos roofing of its durability under all weather special strength. conditions and affords a posi Made of three plies of asbestos felti Packed in one-square rolls which include completing mate rials and instructions for appli cation, Shipping weight, ap proximately 60 lbs. per. square. . - Also made in sheets 32" x 80" which are shipped six sheets to a-: spuare.and. five squares ,to.the: prate. Shipping weight -approxi mately 72 lbs. per square, crated,: . including' completing materials and instructions fox application. JohnsManville fiEXSTONi asbestos roofing tive, firm, constant grip, on the particles of the surfacing. Furnished with a surfacing of . crushed red, green or blue-black slate. The choice of surface color is merely a matter of per sonal taste or of harmonizing the roof with the side-wall color ing. v Packed in y One-square rolls which : include : completing ma-. Aerials and instructions for. ap plication:, Shipping weight, ap proximately 80 lbs. per square. Extra Heavy ; . The heaviest type of Flexstone. Made of four plies of as bestos felt. Particularly adapt ed for service where acid or gas conditions exist. Furnished only in sheets 32" x 80". Packed in crates, 6 sheets to.the square; 4 squares to the crate. Shipping weight approxi mately 95 lbs. per square, crated, including completing materials and instructions for application. Industry has found in Johns-Manville Flexstone and other Asbes tos Roofings the cheap est per year roofings. Underwriters' Approval Johns-Manville Asbestos Ready-to-lay Roofings, Flex stone and White Top Brands, are approved by Underwriters' Laboratories, Inc., and take base rates of insurance. And they are backed not only by a definite guarantee, but by the broader and more satisfac tory terms of the Johns-Man ville plan of Roof Registration, described on page 119. 142 CRMC-003506 JohnsAianville Service to Railroads White Top (Brooks Brand) Asbestos Ready Roofing OHNS - MANVILLE White Top white side is exposed the pitch of the roof J (Brooks Brand) Asbestos Roofing is must be at least 3" to the foot. particularly adapted for saw-tooth con Made in two weights--heavy and extra struction and buildings where the whiteheavy. Heavy is shipped in rolls of 1 or surface of the roofing has the advantage2 squares which include necessary com of reflecting a maximum of sunlight into pleting materials and full instructions for the interior of the building; also widely application. Approximate shipping weight used on buildings where a clean, neat, 62 lbs. per square. Extra Heavy is fur white roof surface is desired. nished only in sheets 32" wide by 80" long, Made of two or three plies of asphalt 6 sheets to the square; 4 squares to the impregnated asbestos felt and one ply of crate. Approximate shipping weight 90 unimpregnated (white), asbestos felt, ce lbs. per square, crated, including complet mented together with asphalt. It can be ing materials and instructions for applica laid either side to the weather but where tion. Safeguard the Application with Pyramid Kaps (Fig. 1) (Fjg.. 2) -Under the old system (Fig. 1) nails driven into cracks work loose and eventually come. out,= leaving, holes through both layers of roofing, causing leaks. X Under the.Pyramid Kap.System (Fig. 2) the continuous pressure of the strip and, the adjoining, kaps eliminate all trouble from this source. :. -We recommend the application ofall - nailing points and to tear away at the laps pur/ Ready-today Roofing's ..with. Pyramid under the strains from expansion, con Kaps. . These are .patented fasteners that traction and wind pressure; exert,a positive, even and continuous pres-*, sure along all'laps, and provide a more sat-: isfactory weathertight and watertight,job than -is possible with nails and cement. Pyramid Kaps are designed for quick and easy application and applied, end to end, along the entire length of all horizon tal and vertical laps, provide a continuous, evenly distributed pressure at all points where the roofing felts are joined. Experience clearly shows that nails driven through tin caps or large headed nails and cement are woefully inefficient. Their principal fault is that they offer but a relatively small and intermittent binding 90% of all leaks experiericed.-With readyto-lay roofing can be traced to faulty laps which are so difficult , to avoid when only nails and cement are used in the applica tion. These troubles are positively avoided by the use of Pyramid Kaps, which in ad^ dition to their great efficiency enhance the general appearance of the finished job, giving a neat, standing-seam effect. Pyramid Kaps are furnished only when ordered, and at slight additional cost, but this is negligible when their advantages and the satisfaction they afford the user are considered. pressure over the laps (when spaced the Be sure to specify Pyramid Kaps in usual 2" apart) and permit the roofing your orders for Asbestos Ready-to-lay fabric to pucker and buckle between the Roofing. 143 CRMC-003507 Johns-Manville Service to Railroads Standard Specifications for the Application of Johns-Manville Asbestos Ready-to-Lay Roofings OR Asbestos Ready-to-lay Roofings Fapplied over wood sheathing, moni tor type roofs, slow burning mill con tra Heavy); Johns-Manville White Top (Heavy and Extra Heavy) and Flexstone Asbestos Slate Surfaced Roofing. struction with saw-tooth roof, steep surOn White Top Asbestos Roofing and faces, etc. Flexstone Asbestos Slate Surfaced Roof Note: The following specifications ap ing there is a black selvaged edge on one ply to Johns-Manville Flexstone Asbestos side to permit proper joining at horizontal Roofing (Double Coated, Heavy and Ex laps. Materials Asbestos roofing, 32" wide, ready for applica tion, to be Johns-Manville Asbestos Ready-tolay Roofing..............................................................Brand. Cement for laps of roofing to be Johns-Man ville Lap Cement. Roofing Fasteners to be Zinc ^Pyramid Kaps and special galvanized round head Pyramid Kap nails; or large head, galvanized roofing nails. Flashing materials as specified hereinafter. Gutters and valleys to be lined with JohnsManville Standard Asbestos Built-Up Gutter and Valley Lining. Such materials shall be applied over wood sheathing as follows: Application of Materials \ .1. When in rolls cut the roofing materials into With the Flexstone Double Coated Roofing lap sheets approximately 13' 6" in length. When in the end joints 4", applying a coating of lap ce sheets apply as received. Commence at eaves or ment in the joint.' : gutters; and :apply' Such sheets parallel with them, 4. Secure all horizontal lapped joints: with .flush with \edge and over edging, strip of special Pyramid Kaps butted end to end approximately : -.flashing material, . which shall; have , been prev.- l/z" from edge of sheet or with large head gal . iously applied. :; : vanized roofing nails on about 2" centers y" h . 2. Lap horizontal joints 25, and apply an -in ..'.from-- edge of,sheet. . Secure .all vertical butted, termediate layer of Johns-M:anville Lap Cement. joints-in a similar-manner applying-one row. of 3. Lay sheets so that vertical'joints will break fasteners.on each-side of vertical joint about yr. joints with preceding courses of sheets as in brickwork. Butt the ends of the sheets at veftical joints closely together without lapping. Lay,- with blabk side up (in all cases), the 6" wide strips of asbestos felt (furnished with all JohnsManville Asbestos . Ready-to-lay Roofing except Flexstone Double Coated) underneath each vertical joint, extending it 3" on each side of joint for entire width of roofing sheet. Be sure that lower end of butt lap is led out on top of sheet below. Cover each strip of felt furnished for a butt end joint with lap cement, and imbed the back from same." A" With the Flexstone Double- Coated Roofing secure all vertical lapped joints with the large head nails spaced 1" apart,, staggered, or with the Pyramid Kaps butted end to end. 5. Extend top sheets on each side of ridge approximately 2" over ridge; lapping one sheet over the other and nailing on 9" centers. 6. Apply a capping or finishing strip cut from roofing material, approximately 10 y2" wide, lengthwise of ridge; extend it equally on each side of ridge and thoroughly secure its lower edges with large head galvanized nails or Pyra butted ends of roofing sheets into this cement. mid Kaps. Flashings Walls and all other elevations above roof surface shall be carried vertically at least 12" to provide for proper flashings. If such flashings are to be constructed in accordance with Johns-Manville Asbestile System, such walls and other elevations need not extend more than 8" to 10" 144 CRMC-003508 Johns-Manville Service to Railroads above roof surface, unless otherwise demanded by local building authorities. Roofing material shall be carried up on vertical surface approximately 2". All flashings, except those around ventilators, standpipes, exhausts, etc., shall be composed of base flashings, of special Asbestos Flashing Material, approxi mately 1054" wide, cemented and nailed to ver tical surface. Such flashings shall be counterflashed with Johns-Manville Asbestile System. Preparation of Roof Surface (To be inserted in Carpenter's Specification) Roof surface shall be graded to drain all water freely into gutters and downspouts. Sheathing boards shall be dry, well seasoned and of uniform thickness, laid closely--tongueand-grooved sheathing preferred. Ends of all sheathing boards shall rest on and be properly secured with at least two nails to joists or pur lins. If edges of sheathing boards are curled up, they shall be drawn down and properly secured to joists or purlins, eliminating all standing nail heads and other projections. All loose knots and other flaws shall be removed, and all holes prop erly filled or covered. All loose nails, chips and other rubbish shall be removed and the deck made and maintained perfectly clean and free of all obstructions other than tools and appliances of roofer. All drainage connections shall be set to permit free flow of water. A 3" x 3" triangu lar wood strip shall be furnished and installed (wherever base flashing is to be used) in the angle formed by the roof and vertical surface. All to be done by owner or contractor other than roofer. Details of Application of Johns-Manville Asbestos Ready-to-lay Roofing. Drawing R-25. 145 CRMC-003509 Johns-Manville Service to Railroads Washington Power and Reduction Co., Republic, Wash., showing application of Asbestoside with batten strips placed over vertical joints. Johns -Manville Asbestoside OHNS-MANVILLE Asbestoside is an. Can be applied perpendicularly or horh asbestos sheet. Wall1 siding (without . zontally. When applied, perpendicularly metal reinforcement) for . application , the three ply roll stock should be used and directly. oyCr sheathing on section houses; "wooden batten strips should be applied stations, grain elevators, repair shops, and .over all joints, thus giving an attractive : other, byildingsi' t^here protection against half-timber effect.': fire, water, gases., chemical- fumes and all Completing materials consist of large weather conditions is desired. , .head, thin shank, galvanized nails,-or This, material, is composed of two or Johns-Manville Pyramid Kaps, as ordered. three plies of asphalt impregnated asbes Star Brand (3-ply) is furnished in rolls tos felt and one ply of: white or unimpreg of one square of 108 square feet or two nated asbestos felt, all. cemented, together squares of 216 square feet, weighing ap at the factory with asphalt. The unim proximately 64 lbs. per square; also in pregnated sheet of asbestos felt produces sheets 16 x 50" weighing approximately a white surface on one side. The material 70 lbs. per square, crated, without com can be applied either side to the weather. pleting materials. Shipped in crates con When the white side is exposed it pro taining 1 to 5 squares. vides a clean, attractive surface that im Shield Brand (4-ply) is furnished in 16 proves the appearance of the building. As x 50" sheets only, weighing approximately Asbestoside is a non-conductor of heat and 90 lbs. per square, crated, without complet cold, it keeps buildings cooler in summer ing materials. Shipped in crates contain and warmer in winter. ing 1 to 5 squares. 146 CRMC-003510 Johns -Manville Service to Railroads Standard Specifications for the Application of Johns-Manville Asbestoside (Exterior Wall Siding) Applied Horizontally Material to be applied over siding of building that sheets will butt against casing, covering the as specified shall be: 3" extension of strip previously applied under Asbestos Sheet siding ready for application in sheets 16" x 50"; to be Johns-Manville Asbesto side, Star or Shield Brand. Fasteners to be either Johns-Manville large headed galvanized roofing nails or Pyramid Kaps and special nails, as specified. Such material shall be applied over wood sheathing as follows: If corner boards are to be used first apply a strip of Asbestoside of sufficient width to cover corner of building and extend 3" from under cor ner boards after they have been applied. The joints of these strips to be butted. casing. Siding sheets shall be applied, white side to the weather longitudinally and parallel with the cornice and eaves. Perpendicular or cross seams shall be lapped 3". Horizontal or long seams shall be lapped 2". Start first course at top with a full sheet, tuck ing the upper edge of same underneath the finish or frieze board. Start the second course with a half sheet so that succeeding joints will break in the center of the sheet above. Start the third course with a full sheet, the fourth course with a half sheet and so on in ro tation to break joints. Top of door or window openings shall have a To insure the proper alignment and the even strip of Asbestoside approximately 10" wide ap application of Asbestoside, chalk lines should be plied, so that it will rest on and extend over the snapped across the building. face of the casing.. \ All seams shall be properly secured with large Sides and bottom of door and window openings head roofing nails or oval head nails and Pyramid shalbbe faced with a strip of Asbestoside of suffi Kaps. If large head nails are used they shall be cient, width, to extend 3" beyond edge of casing. spaced on 2" centers $4V'"back from the edge of The joints of-such strips shall be butted. sheet. If oval head nails and Pyramid Kaps are Corner boards and dobir and Window casings : used Kaps shall be butted end to end and placed may' now be installed.' If-corner boards are not 34" back from edge of sheet. to be used apply Siding so. that sheets will extend : If corner boards are not used apply, over cor- flush with corners' :f. the- building.; If corner : ner of building arid Asbestoside previously ap .boards; are.used: apply. Siding so that sheets will ; plied, 8" wide strips of Asbestoside bent at right butt against corner.- boards,-, covering, the 3" ex `.angles so that they; will lap 4" oh the Asbestoside tension of thel strip previously installed, under- . . on each side*. These strips to be fastened along neath corner boards. '> both edges with large head nails or oval, head At door and window openings apply Siding so nails and Pyramid Kaps, \ Applied Perpendicularly Where it is desired to apply Asbestoside perpendicularly: material in roll form 32" wide to be used. Sheets are to be cut from the roll not more than 10 ft. long. The details of application, strips, lapping, fastening, etc., are the same as when the material is applied horizontally. If desired, unplaned wooden battens, 3" :to 6" wide, may be applied over the laps of the finished job, thus- giving the building a half timber effect. These strips may be stained or painted as desired, Preparation of Surface (To be inserted in Carpenter's Specification) Sheathing boards shall be dry, well seasoned and of uniform thickness laid closely, tongue and grooved sheathing preferred. Ends of all sheath ing boards shall rest on and be properly secured with at least two nails to joists or studs. If edges of sheathing boards are curled up they shall be drawn down and properly secured to joists or studs eliminating all standing nail heads and other projections. All loose knots and other flaws shall be removed and all holes properly filled or covered. All to be done by owner or other con tractors. 147 CRMC-003511 CbjAC-003512 Johns-Manville Service to Railroads /"T^O withstand successfully the excep- and acid fumes and second, because it. is I tionally - severe conditions encoun- specially designed ior the purpose. tered on railroad; locomotives, ,a roof ing material for .such purposes must not' .only resist the direct; and continuous at , It is made of asphdlt impregnated tos felts with a special reinforcing web of asphalt saturated fabric of asbescentre great tack of smoke, soot, steam' and sulphuro-us tensile strength. It is fire-safe and never acid fumes, but it must be positively, fire- needs paint or similar maintenance. safe because of the constant exposure to sparks and hot cinders. Johns-Manville Cab Roofing has been ' It must have the maximum of tensile' an accepted standard of locomotive build strength to take care of the vibration and ers and designers and railroad mainten movement of the cab frame. It must be ance engineers for many years because of extremely compact and dense to resist the its durability and economy. effects of driving rain, snow and sleet as well as the surface friction and terrific wind pressure created when the locomo tive is at high speed. Johns-Manville Cab Roofing is particu larly satisfactory, durable and economi cal; first, because it is immune to smoke Specifications for Application Remove all loose nails, chips, or other rubbish, leaving the surface perfectly clean and smooth. See that all boards are resting on purlins so that they cannot spring and that they are fastened securely with at least two nails at each purlin. 149 CRMC-003513 i Johns-Manville Service to Railroads Roofing is furnished 32" wide and should be cut to suit width of cab, and laid with a 254" lap, thoroughly cemented with Johns-Manville Lap Cement and nailed with large head galvanized iron nails spaced not over 1 y2" apart. Roofing to be laid crosswise of cab. Johns-Manville Asbestos Barge Roofing ROOFING material for barges must A not only withstand particularly se vere weather conditions but it must possess exceptional tensile strength. The movement of a barge in rough water and straining due to the pull of tow lines are all transmitted to the super structure. Ordinary roofing used for building purposes would be impractical for use on barges. It cracks under these strains and requires constant patching and painting to retain its waterproof qualities. Johns-Manville Barge Roofing is not subject to these limitations because it is an asbestos roofing and is specially de signed for marine service. It is made of asphalt impregnated asbestos felts with a special reinforcing center web of fabric of great tensile strength. It does not rot or dry out and it does not require painting or surfacing of any kind. Being mineral it is unaffected by the ac tion of salt air. It is the ideal material for the roofing of barges and similar craft. Made in sheets 32" x 80"; packed 4 squares to the crate. Shipping weight, approximately 90 lbs. per square includ ing completing materials. Johns-Manville Asbestos Barge Roof ing has been used almost exclusively for many years in roofing barges for railroads and private companies operating in the waters around New York. Specifications for Application Remove all loose nails, chips or other rub- iron nails spaced not over 2" apart. End laps to be bish, leaving surface,-perfectly, clean. See that all butt lap construction. Where desired to protect ends of boards are.resting-on and securely nailed, nail heads against exposure it is recommended to supports so that they cannot spring. . that all joints and nails be covered with a 4" .-A'. wide strip of impregnated 14 lb. Asbestos Felt, Roofing is furnished 32" Wide and should .he . laid in. and mopped on top with hot Johns-Man- , laid with 2" lap, tho.foughly cemented wifh: Johns- ville Asphalt Cement. -Roofing to be laid cross- Manyille Lap Cement and nailed, with galvanized wise of barge. . 150 CRMC-003514 Johns-Manville Service to Railroads An installation for M. L. Shoemaker, Philadelphia, Pa. Note the neat gray finish and the continuous horizontal. arid vertical lines made possible by the special cut corner construction. Johns-Manville Transite Corrugated Asbestos Roofing and Siding A PARTICULARLY economical, dur- strong sheets of solid mineral. It is ideal able and fireproof roofing and sid- for many conditions, particularly on low .ing .for application directly , over .buildings over boilers and where sustained purlins or girts in skeleton frame construe^ high temperatures or condensation and tiori, or over wood sheathing; corrosive fumes make the use of ordinary A material that will, not rot,trust or corrugated roofing impractical and expen- burn; that never needs paint; that is im- sive. Transite Corrugated does not warp, mutie to alkalies, gas fumes and most 1 crack or peel. It is unaffected by temper- acids. A rigidj corrugated slab of mineral ature differences. It is: practically inde-. that actually grows tougher with age. structible and this fact assures the long- Made of Asbestos'fibres and Portland est, most economical and satisfactory ser- cement molded under great hydraulic vice, pressure into dense, tough, structurally Can be used on Spans up to 45 inches Because of its unusual strength, Transite Corrugated Asbestos Roofing and Siding can be laid on spans up to 45" directly on the purlins or girts. Our en- gineers may be able to help in making a substantial saving of structural steel where a building has not yet been erected, 151 CRMC-003515 Johns-Manville Service to Railroads Economically, Quickly and Easily Applied Johns - Manville Transite Corrugated Asbestos Roofing and Siding has none of the disadvantages of metal roofing, which is always liable to rust or corrode and al low water to drip in on valuable stock or machinery. The history of a metal roof is one of expense for constant painting and patch ing and within a few years, replacement. When once erected the metal sheathing cannot be painted between the laps, under flashings, or on the underside where it rests over the purlins or girts. It is at these vital points that rust starts. The metal becomes thinner and thinner and finally gets beyond repair. The history of Transite Corrugated As bestos Roofing and Siding, on the other hand, is one of long life, low cost and min imum upkeep expense; It never needs paint or other protection to help it keep its original structural strength--in fact it actually grows tougher with age. Johns - Manville Transite Corrugated Asbestos Roofing and Siding requires no special tools for application and can be in stalled as rapidly and in the same general way as other corrugated material. It can be readily sawed, punched or drilled and fastened with bolts, nails or screws, as shown on page 156. The extra width of the sheets in which this material is furnished requires the handling of fewer sheets and the making of fewer laps, thus permitting a substan tial saving in labor and materials as com pared with ordinary corrugated roofing. Johns - Manville Corrugated Asbestos Roofing and Siding presents a clean, neat, gray finish which lends an attractive ap pearance to the building. Where Used - Reco-rnrnended fqr use on engine houses, bridges over tracks, or any place where boiler houses, chemical and fertilizer, roofing or siding of this type can be used, .plants* warehouses, .piers, coal; .bunkers, .. On sawtooth robf construction it pro- . hangars, oil houses,; elevators, . boating vides a maximum of light reflection into plants,- garages* car .barns, train: sheds, the interior of the buildirig in addition to .awriings and sheds overloading platforms, durability and economy. . bridges between buildings, covered , !. 152 CRMC-003516 Johns-Manville Service to Railroads Cut Corner Construction --A Feature A feature of this mate rial is the manner in which sheets are butted and lapped at the corners, which is provided for by special cut corner con struction. These cut cor ners eliminate a thickness of material where the four sheets come together in the corner lap, thus allow ing the sheets to nest per fectly at these points, per mitting them to be laid with laps forming contin uous horizontal and verti cal lines. This improves the appearance and elimi nates cutting of sheets at one end of thebuilding; The inside add outside radii; of ' the corrugations are the . samej thereby, allowing the.. sheets to . nest perfectly-at all laps.O'..' All of the foregoing fea- . tures pr ovide . a; more weathertight, watertight . and better looking job than is possible with any ::: similar type of roofing. Our engineers will be glad to go over plans and discuss, the use of Transite Corrugated for new build ings, or for the replace ment of roofing and siding on buildings already in service. How Furnished Johns-Manville Transite Corrugated Asbestos Roofing and Siding is fur nished in sheets 42" wide, Bevel Cut Corners of Transite Corrugated Asbestos Roofing 1. Corner drawn apart. Extra thickness is avoided by butting the two bevel corners in stead of lapping. 2i. Upper-, bev.el. sheet moved : i'nto ..place. ': When , remaining top sheet' is in -position, fhere.; .are ' no crevices : for:.'the weather: to e.riter. 3. Complete corner. Note the vertical as well as horizontal laps form continuous straight lines, a better looking job than the custom ary staggered vertical lap. 153 and in standard lengths of 4, 5, 6, 7 and 8 ft. Sheets can be furnished, on spe cial order, cut to any de sired length possible from the above mentioned stan dard sizes. Comes in two thicknesses, approximately and y<l'. This material is smooth on the weather side, the other side being slightly pebbled. Special Curved Sheets Where it is desired to use curved sheets, they can be furnished, on special or der, curved at the factory with the following limita tions; sheets may be curved longitudinally, the arc being formed along the direction of the corruga tions. Minimum radius when so curved 48". Sheets may be curved ; Crosswise,. the arc being formed across the cbrruga-, i tions.; Minimum . radius when so curved 12". Sheets may; be. curved either way. but not in combination; The' same materials that are used in forming the corrugated sheet are moulded at the factory in to, special standard shapes to be used : as ridge roll, corner roll, louvres and ventilators; see pages 156, 157 and 199. Flat sheets can be furnished as de scribed on page 188. All of the above mentioned materials are particularly designed to be used in con nection with the corrugat ed material, but can also be used independently. CRMC-003517 Johns-Manville Service to Railroads Fasteners especially designed for use in connection with this material can be fur nished by us. This material may be laid on roofs pitched 2" to the foot and over. Where pitches are from 2" to 4" to the foot, Johns- Manville Asbestos Roof Putty is to be used in all laps. Where pitch is over 4" to the foot this precaution is not necessary unless extraordinary service conditions demand it. A Tested and Proved Material Asbestos is a mineral that withstands all the destructive forces of nature. Port land cement is used universally in build ing for permanence. These materials com bined in Transite Corrugated Asbestos Roofing and Siding, make the ideal mate rial for skeleton frame construction. This product is simply a different form of a time-tested material. It is the same as Johns-Manville Transite Asbestos Wood which has been used in railroad and in dustrial construction over a period of many years as fireproof roofing and sid ing, partitions, walls, ceilings, in fact, any where a fireproof and durable material is needed. This tested and proved material is cor rugated to give greater strength thus al lowing for its use as roofing and siding over widely spaced purlins. This building of the Iowa Southern Utilities Company, Centerville, Iowa, will be free from roof troubles practically as long as the structure stands. The natural gray sur face of this Transite Corrugated. Asbestos Roofing never needs paint or other protective coating. David F. Fisher & Co., Engineers. 154 CRMC-003518 Johns-Manville Service to Railroads Standard Specifications for the Application of Johns-Manville Transite Corrugated Asbestos i Roofing and Siding ROOFING AND SIDING enabling material to be laid with side laps form Where shown on plans, the roofs and sides of building shall be covered with Johns-Manville Transite Corrugated Asbestos Roofing and Siding ing vertical lines. Sheets shall be laid with 6" end-lap and two corrugations side lap. as manufactured by Johns-Manville Inc. The FLASHING (AND BUILDING TRIM) i material to be of a dense, homogeneous construc Where shown or indicated on plans Ridge Roll, tion, weighing approximately 3.5 lbs. per square Corner Roll, Louvers and Flashing to be of the foot, and to be approximately thick at ridge same material as the roofing and siding. All other and valley of corrugations and approximately y flashing to be of 4 lb. Sheet Lead. thick on slope. FASTENERS When J/i" material is to be specified cross out above data on weight and thicknesses ONLY and substitute Johns-Manville Standard sheradized or galvan the following: ized Fasteners shall be used. Heads of all fasten Weighing approximately 7 lbs. per square foot, and to be ers on weather side of building shall be protected approximately $4" thick at ridge and valley of corruga with Johns-Manville Asbestos Roof Putty. tions and approximately l/i" on slope. METHOD OF APPLICATION Sheets shall be 42" wide and of suitable length The method of application shall be in strict .so that all end-laps shall occur over a purlin or accordance with the manufacturer's standard girt. Sheets shall be furnished with cut corners erection instructions. Types of Johns-Manville Transite Corrugated Asbestos Roofing and Siding, (/" thick) Louvres, Ridge Roll, etc.--Drawing AW-1. 155 CRMC-003519 Johns"Manville Service to Railroads Tgcei'A ridye ro// OSfiAOsrr.&Sr. o^'A4s"c~e2sn'"*k^^css-/o*aicAefdrs s"e/>om. G.I--on each sSe'e. XrkcfooTty (gray) may be ose</ tf regu. ` / Pars.-long Softant/ Jagg/e az sfiotvr? 6e6>uj moy he used if c/esired. UP--j/b*7eCsTobrrs. TWrooncsct/'/? C. / P/jn/er -/ t/om. ype U ooTfen 6" /ong: --. ' \ ^V /Butt'joint.... Tupe ld_ ridge rc /J51DF. VIEVS OF Rip<5.& BATTS// lypeU boT/en sTd 6>"/ongxTh 7o /// ouer 6*6" Type Xd BaT/en 7o 6s 6o/fed 7o_ ridge sec7rorrs^ T,;/puffy-?-zg 4i.c\7,j97*\ lana ia> ? - 3~'?&/*-j Type V -- sfosK/*/'^S-3" Co/a Jr9P iVaiAer -/pdon Jiwon'aofftXiz$ X J 7& -- c aacu>ra/u bo/?9^ to r~oa~* n> 7ype (V ridge ro//. tff'O'fang a >f /t> , *'4>cnr fo &C>*anj. / roof puTT'! my ;/r of Sftr/pa fX,"'* Vfismcc/. Type X/ ridge ro!/ -0~ Tong X - 'fb. x 6"*. 6 " totngs -- sections 6<jT7e</ /a<je/6er 4-_ >o/Ts psr boT/en f/z teach tsidej /S' * ^rzneratd /"dtom. G / cuazber eacn side. Gray poo/pu'77ty ooer. This s us fen of Ridge feo/i is odjusTab/e To ony pifchr Ridge Roll for Johns-Manville Transite Corrugated Asbestos Roofing and Siding. Drawing AW-3. 156 CRMC-003520 Johns-Manville Service to Railroads A// Corner- X?oft to hove buff joints os fo/touis -- A--&utt joint, may be covered ur/ft type (J hotter) ffor 6x6" "type ht)set m grot/ roof putty ~7~he top s/tde of batten to be poinfed~vp ui/tti gray roof pet ftj/ as sbo tun B --Between The butting ends of corner ro// insert a sheet /each si// about 6" uuide (or more if necessary) mode of *5* Jb. /ead -Some to be carried up inside of top. ro// earned thru joint and brovq/t dacon oner outbids of bottom ro// oboad -s'-' to be botted To ~/op ro// os shocun. ______ . ...................................... ___________.__________________________________________ CRMC-003521 Johns-Manville Service to Railroads Men/for roof. ^00000000 /`lain roof. Shapes of sheets usee/ above. 00 2! --App/teJ fie-gt. . /tea rocona^ ot/erfapp/rtg **/ 7Z+c co^^g. 43.. ~4pp//c<f fcusTh--over #j2 a/fc/ C*3om. e/ 4*J2. J-M LAP -- PATEftT APPLIED FOR 00S0B000 JZ7Lt;Zr ^ 00000000 reef B0000000 3/ieeTs regci/rcc/ for >ui/efir>g os s^Oujn. 4 T^url/p *ss'?re'ms requirec/ per-s/teef for roofing. PttMOS or CVTTIh'G BEVEL COZYSP. fibre-/f rails are usee/ theef ekou/d be spoccc/ every o7uer corrugation. Details of Application,;d Johns-Manville Transite Corrugated Asbestos Roofing atid and Siding--Drawing AW-7. 158 CRMC-003522 Johns -Manville Service to Railroads UNITED STATES GOVERNMENT BALLOON HANGAR, SCOTT FIELD, ILL. - - . Erection supervised by. Construction Quartermaster. This is one of a number of balloon hangar installations on which the in sulating value, of Asbestos Protected Metal plays an .important part and - assures strength, ' long life and freedom from maintenance expense. The United States Government is a large and regular purchaser of this product. Asbestos Protected Metal Roofing and Siding HIS is another type of corrugated asbestos roofing and siding. Like Transite Corrugated Asbestos Roof ing and Siding described on pages 151 to 158, Asbestos Protected Metal is intended for use over skeleton frame construction, or wood sheathing. However, these two materials are distinctly different in ap pearance and general characteristics. They are made of different elements and in a radically different manner. Asbestos Protected Metal is a light, strong, permanent, acid, alkali and weath erproof building covering. It is easily handled and can be erected without regard to weather conditions. Its long life, insu lating qualities and the elimination of painting and maintenance costs effect large financial savings. Asbestos Protected Metal combines in one product all the merits of both corru gated metal and the best built-up roofing. In effect it is a corrugated steel roof on which a perfectly made built-up roofing has been applied at the factory to both surfaces under exact heat control and exact pressure. Asbestos Protected Metal has many times the insulating value of corrugated steel. This is the reason, as shown by ser- 159 CRMC-003523 Johns"Manville Service to Railroads vice tests, that buildings on which it is used in tropical countries are so much cooler and more comfortable to work in, as well as more attractive in appearance and more durable. As no thinners or driers are used, the coatings set up hard and tough when exposed to the sun. In cold countries the insulation results in buildings being easier to heat than those covered with unprotected metals. The original product has been constant ly improved until today it has a number of exclusive patented features which greatly add to its quality and durability. The pro duct is not new or untried. For many years it has stood the test of service on buildings where conditions are the most severe that can be encountered. The foremost American, Canadian and foreign industries have used it exclusively under a great variety of conditions for new construction and for replacing other old or wom::out materials: The ease and speed with which it rhay be erected and; freedom from Jitter allow continuous plant opera tion, ^making it; specially desirable for re newals. permanent construction at a price that ma terially reduces overhead charges. The base, or core, of Asbestos Protected Metal is a specially annealed steel sheet. The surface is thoroughly cleansed of rust, grease, moisture or any other substance that might interfere with the perfect bond ing of the three protective coatings. The sheets, or shapes, are then immersed in the first asphaltic coating. When the asphal tic coatings are applied they are all heated to definite and uniform temperatures. How Asbestos Protected Metal Is Manufactured A SBESTOS Protected Metal is made /-V by combining steel sheets, (of 18, 20, 22, 24 or 26 gauge) asbestos and three different asphaltic compounds, each being prepared to meet a different require ment. They are the result of seventeen years' experience, together with investiga tions by able engineers and chemists and by the foremost chemical research organi zations. Considered from either an erec tion or maintenance viewpoint Asbestos Protected Metal offers building owners Sample of Asbestos Protected Metal with portions cut away to show relative position of the three corrosionproof and insulating coatings with steel base or core. 160 CRMC-003524 Johns-Manville Service to Railroads The first asphaltic coating forms a thick, special process before leaving the factory, elastic, gas and moisture-proof shield that so that no metal is exposed. entirely encloses the metal., The coating is soft, the asphaltic base containing oils that help to keep it "live" and at maximum effi ciency long after ordinary coatings have outlived their usefulness. This coating is then completely encased with a tough sheet of asbestos felt thoroughly impreg Asbestos Protected Metal can be fur nished coated on both sides with aluminum paint. This finish has the limitations of other paints in wearing qualities but fur nishes an excellent priming coat for suc ceeding paintings. nated with asphalt. Specially selected asbestos fibre is used in the manufacture of this second, or mid dle, coating. It is made by a special pro cess, and is so constructed that it can be impregnated with the asphalt to the best advantage. The asphalt impregnated asbestos felt is laid over ,the still hot first , coat and forced against it under.heat and pressure in such .a way that the steely the first coat and the asphalt impregnated asbestos felt - Corrosion Proof The great resistance of Asbestos Pro tected Metal to corrosion under the most severe conditions that industrial and rail road buildings encounter is important. It is impervious to moisture, salt air, mine water, condensation, acid and alkali fumes, even in combination with high humidity, coming in contact with it from either in side or outside the building.1 Now that the destructive.force of corrosion is gaining recognition the resistance: of Asbestos are thoroughly" and permanently bonded. Protected Metal to this destructive action The felt forms ail opaque insulating cover is becoming more appreciated. > ;: ing and protects the first coat from light, Corrosion is Sometimes called "theslow v.heat and mechanical abrasipn. On the two fire." Although less spectacular than: fire side edges the felt: is folded over and both it is now believed to cause even greater ends are closed so that the first- coat is her-:, losses--and they are not covered by insur metically sealed.: .A V.v;-S: . VA'>. ance. It is intensified by sulphuric, bold, A ; Finally the asbestos coating is protect-', sulphurous, acid, hydrochloric acid and ed from mechanical abrasion by an ex^/ ammonia compounds contained in soot. : elusive patented / waterproofing. - This' Wherever coal is burned these elements waterproof - coating, either black or ma roon, as Ordered, is applied at a high tem perature to: the asphalt impregnated as are created, so that plants located in "pure" country air generate their, own de structive elements. .... bestos felt forming a tough- and elastic The University of Pittsburgh investiga surface that allows the material to be tion showed losses due to the destructive handled freely in shipment and erection action of smoke in this country each year without damage to the protective coating. exceeding the cost of the Panama Canal, This coating is not affected by natural and that if the acid content in smoke from temperature changes. It is easily handled Pittsburgh chimneys, alone, in one year in summer, as it does not melt; and it will acted entirely upon structural steel 265,000 not chip or crack in cold weather. tons would be dissolved. Where necessary to cut sheets for build Much of the building part of this in ing trim, ventilators, skylight metal parts, vestment loss can be prevented by the use etc., all exposed edges are treated by our of Asbestos Protected Metal. 161 CRMC-003525 Johns-Manville Service to Railroads Roof Pitches Asbestos Protected Metal corrugated sheets can be used on any roof pitch on which other corrugated sheets can be ap plied. Where the pitch is less than 4 inches in 12 inches both side and end laps should be laid in asphaltic cement. Cor rugated sheets should not be used on roofs with a slope of less than 2 inches in 12 inches. Forms and Sizes Asbestos Protected Metal is made in a variety of standard forms and sizes which good practice has demonstrated to be most useful, economical and attractive in the general run of construction work. Besides roofing and siding sheets we supply ridge caps, flashings, louvers, ventilators, sky lights,made of Asbestos Protected Metal. Corrugated Asbestos Protected Metal sheets are 27%" wide and are. carried in stock lengths of even' feet from 5 to '12 ft. inclusive. They have 10% corrugations each 2%" wide and %" deep. They have a net covering width of 23%" with 1% corrugations side lap. See drawing on page 164. Standard Mansard sheets possess ar chitectural advantages for both roofing and siding purposes. It is a sheet 27 %" wide showing five beads, each bead meas uring 2" wide by %" high. Sheets are made in lengths of even feet from 5 to 12 ft. in clusive with a net covering width of 24" per sheet. Standard flat sheets are 30" wide and furnished in lengths of even feet from 5 to 12 ft. inclusive. They are also made in widths less than 30" for special purposes. They may be used for interior sheathing where desired. Also for making ventilat ing flues, ventilators, acid fume ducts, hoods, conveyor boxes, light partition walls, flashings, etc. Standard fasteners for various types of construction are furnished as required. The constructioh engineers at our near est branch: will be glad to go over, your plans or confer with you personally ; on roofing or .siding problems in connection with buildings of any type or size . Standard Specifications for the Application of tecfed Metal ROOFING All roofing shall be of...;........... Corrugated Asb.estos .Protected Metal. gauge SIDING' '! ' All siding shall be of...................................:Sgauge Corrugated Asbestos Protected Metal. ^ , ( Maroon Color to be )(Black (Maroon Color to be (Black Sheets shall be laid with one and one-half cor rugation side lap, and not less than 6" end lap. Manufacturer's Standard Fasteners shall be used and the method of application shall be in strict accordance with the manufacturer's Standard erection instructions. All flashings and ridge cap shall be of................................ *gauge Asbestos Pro tected Metal and of same color as the roofing. Sheets to be laid with one and one-half corru gation side lap and not less than 4" end lap. Manufacturer's Standard Fasteners shall be used, and the method of erection shall be in strict ac cordance with the manufacturer's Standard erec tion instructions. All flashings shall be of ............................*gauge Asbestos Protected Metal and of the same color as the siding. No. 18-20-22-24 or 2G gauge depending on pwrlin or girt spacing. See page 1C3. 162 CRMC-003526 Johns-Manville Service to Railroads Supporting Purlin and Girt Spacings For Corrugated Sheets on roof structures hav ing a rise of 4" or more in 12", supporting purlins may be spaced as follows: No. 26 gauge for spans up to 3'9" centers. No. 24 gauge for spans up to 4'9" centers. No. 22 gauge for spans up to 5'9" centers. No. 20 gauge for spans up to 6'6" centers. No. 18 gauge for spans up to 7'6" centers. Corrugated Asbestos Protected Metal Sheets for Siding, the supporting girts may be spaced as follows ; No. 26gauge for spans up to 3'10" centers. No. 24gauge for spans up to 4'XO" centers. No. 22gauge for spans up to 5'10" centers. No. 20gauge for spans up to 6' 8" centers. Gauge 26 24 22 20 18 WEIGHT OF ASBESTOS PROTECTED METAL IN POUNDS PER 100 SQUARE FEET OF MATERIAL AREA ALL WEIGHTS SUBJECT TO VARIATIONS Black CORRUGATED OR MANSARD Net For Crated Shipments Add Maroon Domestic Export 138 144 14 165 171 15 192 198 16 218 224 ' 17 272 278 20 20 21 22 24 30 Black FLAT Net For Crated Shipments Add Maroon Domestic Export 128 154 179 204254 134 160 185 '210 . -260. 10 11 12 13 16 16 17 18 21 25 Estimating Data--Method of Estimating Quantity . Areas of Asbestos Protected Metal Sheets may It is, however, .always' desirable to submit be figured by multiplying thej total added, length ^sketches or blueprints, so. that, the correct quan of a number of sheets'by the width, of a .sheet. tity and gauge of sheets,, as well as flashing and ' The standard corrugated and mansard sheets . fasteners can be estimated. Blueprints will be are27}4 inches wide, which is 2.3 feet. returned with our estimates, when: requested. Therefore the total area of sheets given in the following example is as follows: , : Number of Sheets 30 30 60 Length. . 6'0" : 9'0" . io;o" Total Feet 180 270 600 Total Linear Feet ... . 1050 V2.3 3150 2100 Total Material Area. .2415.0 sq. ft. Standard Flat Asbestos Protected Metal Sheets are 30 inches wide, therefore the added length of a number of sheets would be multiplied by 2yz. To obtain an approximate figure on corrugated Asbestos Protected Metal required for roofs and siding add 25 per cent, to the actual building area. This takes care of all end and side laps. SECTION THV.OVCR MONITOR ALTERNATE SECTION AT EAVE 163 CRMC-003527 Johns'Manville Service to Railroads Standard Building Details CRMC-003528 i Johns-Manville Service to Railroads Standard Building Details 165 CRMC-003529 i Johns-Manville Service to Railroads Standard Building Details 166 CRMC-003530 Johns-Maiwille Service to Railroads The artistic appearance, durability and positive fire protection of Johns:Manville Rigid Asbestos Shingles make them ideal lor railroad passenger j' stations-and other railroad buildings. They last the life, of the. building and never require painting or other maintenance. Johns-Manville Standard and Colorblende Asbestos Shingles N. the planning:-.of-modern railroad ter- such a variety of sizes, shapes and colors I minals and suburban, passenger sta-- as to offer the widest range of artistic and tions, railroad Y.M.C.A.'s and similar interesting roofing effects and to provide buildings, the architect or engineer de- the utmost in service, economy, fire and mands a roofing that combines beauty weather protection. with fire protection and durability. He Made of Asbestos Fibres and Portland demands a roofing material that will retain Cement united under great hydraulic pres its artistry and effectiveness indefinitely sure, Johns-Manville Rigid Asbestos Shin- and serve with the same maintenance gles cannot rot, rust or burn. They do not economy as the stone and steel of the foun- warp, curl, split or shale. They are not as dation and walls. heavy as slate or tile. They are simply Such a roofing material is the Johns- a combination of rock with rock--an ever- Manville Rigid Asbestos Shingle, which is lasting roofing material that never needs truly the Aristocrat of Fire-Safe Roofings, paint and lasts as long as the building it It is a solid slab of mineral that is made in protects. 167 CRMC-003531 Johns-Manville Service to Railroads Add Distinction and Dignity to the Building Whether the roofing should have the simplicity of straight lines, the rugged ir regularity and pleasing shadows of heavy butts and rough edges, a bright over-all tone of one color, or a mellow, weathered appearance, the architect will find in the variety of sizes and shapes, the two dif ferent surface textures as well as the color ings of Johns-Manville Rigid Asbestos Shingles an opportunity to obtain just the roofing effect desired. He can obtain a pleasing harmony or a distinctive contrast, as the style of archi tecture, the sidewall treatment, the size of the building or natural environment may dictate. These shingles give a distinc tion and interest to the building which is quite impossible with roofings confined to fewer shapes and colors. The color plates shown on pages 171 to 174 represent only a few of the combina tions which can be obtained with JohnsManville Colorblende shingles. It is quite impossible to reproduce the peculiar charm of a Colorblende roof in its proper setting but these plates will show its at tractiveness and how it may be adapted to particular conditions. The various shades of a Colorblende Roof of Conglomerate Brown alone, or with the Natural Gray or Indian Red add ed, may be laid at random or in accordance with a predetermined pattern or color scheme, the results of both these plans be ing shown in the color plates. Our Architects' Service Department will be glad to confer with architects about the use of either Standard or Colorblende As bestos Shingles for any type of building. Colors, Sizes and Shapes The color range of. Johns-Manville. gles are made in one size only, 9"xl8", Rigid Asbestos/ Shingles includes: a soft/, thick, rough edges, No. 50 or No. 52. Natural Gray, an Indian Red, an Autumn The three shades, Indian Red, Natural Brown arid a composite known as Con Gray and Autumn Brown are known as glomerate / Brown. The Conglomerate . /Brown, blend is made'up of four separate shingles, each representing a different shade of brown, thus producing a subtle, pleasing blend, which can be used alone or Standard Asbestos Shingles and are made in y8" thickness with smooth edges and in *4" thickness with rough edges, in the sizes and shapes shown on page 176 and in the tabulation of construction data on in combination with Red or Gray. All six page 169. of these shades are made in either smooth or rough surface. The rough texture is The Natural Gray, Indian Red and Au particularly appropriate with face brick tumn Brown Shingles, in both and 34" side walls or on buildings of the Spanish thicknesses are not blended one with the Renaissance type. other but are intended for use when a solid To the Conglomerate Brown Shingles, over-all roof tone of soft red, gray or (either smooth or rough texture) when brown is desired. Where a mottled or laid alone, or with any proportion of Colorblende effect is preferred the Con Indian Red or Natural Gray, the regis glomerate Brown shingles alone or mixed tered trade name of `"Colorblende" has with Indian Red or Natural Gray should been given. Conglomerate Brown Shin be chosen. 168 CRMC-003532 Johns-Manville Service to Railroads Ideal from Every Standpoint On account of their practically inde B, when laid Hexagonal method. They can structible nature and their permanent col be applied by any roofer, slater or carpen oring, Johns-Manville Shingles do more ter according to any of the various meth than express the artistic ideas of the ar ods in vogue,--American, Hexagonal or chitect for a short time. They maintain Diagonal (French) on roof decks of ordi their original beauty indefinitely. They nary design. do more than merely cover a building-- The Hexagonal or "honeycomb" method they protect it against all weather condi of application is much more artistic than tions--they require no painting or similar the Diagonal method. In the Hexagonal maintenance and they are fireproof. This method apparently six sides of the shingles is of particular importance in railroad are shown thus overcoming the objection building on account of the prevalence of to severely straight lines and producing a flying sparks and hot cinders. more pleasing effect. It is not only more Whether the first consideration in the choice of shingles is their artistic fitness-- their fire protection and weather protec tion or their economy and permanence, attractive but affords better protection, due to the fact that the overlap at the lower ends is greater. For illustration of various methods see pages 175 and 176 Johns-Manville Rigid Asbestos Shingles Johns-Manville Asbestos Shingles are meet every requirement. covered by the policy of roof registration They are approved by Underwriters' described in detail On page 119. Laboratories, Inc., and are labelled Glass Construction data, drawings and detail A, when laid American method and Glass' specifications are included in this section. Data on Johns-Manville Rigid Asbestos Shingles Catalog Number Size of Main . (Ins.) .Body Shingle . Thick ness. : Approx. . Weight. per 100 .Shingles iLbs.'.. Aoprox,. Weight per Sq. Applied Lbs.i Number Surface Shingles, Exposed per Sq. (Inches ** *3 M* *5 *6* 9 12 *50f *S2t 60 12x12 12x12 8x16 8x16 16x16 1 v" ' 1 <" i v " l _ \s." 12x12 1 s " 9x18 9x18 12x12 \' V 1 V ' 215 205 . 185 175 . 343 200 515 495 480 455 300' 320 320 650 320 740 200 320 300 240 . . 5X12 240 5x12 260 . . 7x8 260 7x8 87 13x13 160 91jx91 < 204 230 160` 8x9 18x3!j 91 vx9 ' > No. of . GMvt ' No. of Storm Sections Ridge Catalog Nails Anchors Number per sq. ReLbs. . quired quired of Starter - per Sq. Lin. Ft. lap No. of Starters Required per 100 Lin. Ft. Method of Laying 2'.y 93 51 I'd"1-. . 67 American 2 ' 93 - -51 i" 67. American 2> 93 51 67 American 2. 93 51 S 67 American 1 87 , 93 17 i V' / 75 1 1'1 s " 1 67 Diagonal 1j 160 93 17 1 1 ,| "1 14 ( ' s"i 75 89 Diagonal 2 93 17. V* 51 i V 75 67 American 2j 93 51 t 67i Longitudinal l; 160 93 17 < ' 4 ' 61 l',"' 75 77 Hexagonal l 87 93 17 i , ") 71 75 58 Hexagonal NOTE.:--With this style cf shingle we recommend Bostcr. -,r Chicago) Hip and Ridge: when used with No, 50 or 52 Shingles allow about 1?. squares extra of No. 50 Shingles i'.r every 100 lineal feet to be covered. When used with Nos. 3, 4, 5 or 6 Shingles allow l:j squares extra of No. 5 for every 100 lineal feet to be covered. f Conglomerate Brown (blend) furnished only in the Nos. 16 and 52 Shingle sizes. No. 52 is punched and intended for application by the horizontal method fthc long dimension paraiieiir.g the eaves). * Numbers so marked have clipped corners. i Order 35 No. 51 starters and halve the long way to get the C7 starters (4';" :: IS"'i. 169 CRMC-003533 Johns-Manville Service to Railroads For Re-Roofing Over Old Wooden Shingles ,A.-most practical and satisfactory way of .fireproofing, and weatherproof ing an.old wooden shingle roof. It not only saves time and expense but avoids the dirty job of ripping, off the old shingles. It also eliminates . painting and similar maintenance expense and the building has been RE-ROOFED FOR THE LAST TIME. . N- old shingle rpof, particularly on a Another advantage is.that the retention A railroad building, is a decided liabil- of the old shingles, provides a double roof ity, not only Oil account of the- fire, which makes a building cooler in summer hazard but'the.constant, painting and raend warmer in winter. ,. pairs which it requires. ' When it must be' replaced the work can be done, for the last, time, and time, money and labor saved in the operation by the application of Johns-Manville (Rigid) Asbestos Shingles. No longer is it necessary to rip off the old shingles. All the dust/dirt and delay can now be eliminated. The old shingles can be left just as they are and Johns-Manville Rigid Asbestos Shingles applied right on top of them. This is the quick, clean, economical and perma nent way to re-roof. It quickly transforms When it comes to the replacement of an old wooden shingle roof on any building apply Johns-Manville Standard or Colorblende (Rigid) Asbestos Shingles right over the old ones. The building will be re-roofed for the last time and perman ently protected from fire and the elements. Over old shingles as well as on new roofs Johns - Manville Rigid Asbestos Shingles are given highest ratings by Un derwriters' Laboratories, Inc; Class A for the American method and Class B for the Hexagonal. a dilapidated wooden shingle roof that is a Note: When rigid Asbestos shingles constant menace into one that is positively are applied over old wooden shingles spec fire-safe and good looking. ify 2" nails when ordering. 170 CRMC-003534 fireproof roof of Johns-Manville "Colorblende" Asbestos Shingles makes a pleasing contrast to the wails of red brick and white mortar. 1 he varied combinations in which these shingles can be laid offer many pleasing effects for every type of building where a colorful roof is desired. 171 CRMC-003535 _jXOTHER colorful roof oj * x indestructible Johns-lMa/reilh- the fireproof, 'll'eat h erp ro of. p ru ctirally Colorblende Asbestos Slutujles. the planting is admirably topped off by the subtle slunl- ' s--one zchit'h ~eill please the most exact i;?//. CRMC-003536 a a rtw JDL'ILDIXGS covered oath Jo hus-Manville " Colorblende" Asbestos Shmrjles are distinctive because oj ike beauty of color oj their roots. When, also, the endurance and fire-safety of "Coiorhlcnd<" S!nu</lcs are considered they become doubly desirable ivhen buildina for permanence. 17 CRMC-003537 the. plain severeness oj .:co walls is relieved by the lively color roof of J ohns-ISIanville S Jorblende" .dshestos Shingles. These everlasting shnu/les are v texture, as suits the individual to. with either smooth or rough surface ' particular architectural scheme. :*4 CRMC-003538 Johns-Manville Service to Railroads Details of Application of Johns-Manville Asbestos Shingles Sketch showing application of Johns-Manville Asbestos Shingles, American Method. NOTE:--The sketch is correct in detail for the application of No. 5 and No. 6, 8" x 16". Where the No. 50, 9" x 18" shingle is to be applied No. 17 is the first starter, followed by No. 51 as a second starter, outlined . in specification at top of.page 177. Sketch^showing application of.' iJohns-Manville Asbestos -^Shingles, Horizontal Method. Sketch showing application of Johns-Manville Asbestos Shingles, Hexagonal Method. 175 CRMC-003539 Johns-Manville Service to Railroads Details of Johns-Manville Asbestos Shingles Hexagonal' Shingle^--Showing. Application' of . Storm "V . Anchor... . Enlarged:. Scale.' Standard Shapes 176 CRMC-003540 Johns -Manville Service to Railroads Specifications for the Application of Johns-Manville Standard and "Colorblende" Asbestos Shingles American Method "Colorblende"* Asbestos Shingles (No. 50, 54" chick, rough edge) Lay roof boards in the usual manner, breaking joints and nailing securely in place with at least two nails at each rafter, leaving no loose ends. The roofing boards shall be well seasoned, of narrow width and uniform thickness; tongue and grooved preferred. Over the roofing boards lay one thickness of Johns-Manville Asbestos Slat ers' Felt, laying horizontally with a 4" lap, and with 12" lap on ridges, hips and valleys. (See detail on page 175.) Apply J4" thick x 134" wide furring strip parallel with and flush with the eaves, then apply one course of Standard.(Brown)* No. 17, 4" x 16" Starters, at eaves lengthwise and parallel to same, overhanging the eaves about 1". Apply, second starter course using Standard (Brown)* No. 51, 9" x 18" Starters, at eaves lengthwise and parallel to same, breaking joints.with and entirely cover ing the first starter: course. Then apply first main body course using'Conglomerate Brown* No. 50; 9" x 18", and (Indian Red* No. 50.9" x 18") (Nat ural Gray* No. 50, 9"xl8") (mark out color not to be considered) Johns-Manville Asbestos Shingles, breaking joints with and entirely covering the starter courses; after which proceed in the regu lar manner as with wooden shingles or slate, ex posing 8 inches to the weather and fastening each shingle in place with two galvanized iron (or copper) needle pointed shingle nails. Never drive the nails down tight; it is only necessary to drive them firmly. The various shades of "Colorblende"* Asbes tos Shingles shall be laid at random. HIPS AND RIDGES Construct "Boston" (or "Chicago") Hip and Ridge using No, 50 Johns-Manville Asbestos Shingles--(color.to be as selected). - FLASHINGS ' Flash all chimneys, ..valleys,: etc.,, with copper or other approved material'. American Method (Shingles Laid Horizontally) .'A <fCdldrblende"*-Asbestos Shingles (No. 52, 34" thick, rough edge) When this specification is used, begin it by re exposing 354" to the weather and fastening each peating the -first ..'paragraph, regarding' the roof shingle in' place with' two--galvanized, iron (or deck; of the-Specification above, continuing as follows: copper) needle pointed shingle nails. Never drive Apply 34" thick x 134" wide furring strip the nails down tight, it is'only necessary to drive parallel with and flush with the. eaves, then apply them firmly. one course of (Brown) 434"xl8'^: starters, (these to : The various shades of "Colorblende"* Asbes be made on the job from No. 51, 9" x 18" starters) tos Shingles shall be laid at random. at eaves lengthwise and parallel to same, over hanging the eaves about 1". Then apply first main body course using Conglomerate Brown* No. 52, HIPS AND RIDGES Construct "Boston" (or "Chicago") Hip and 9"xl8", and (Indian Red* No. 52, 9"xl8") (Nat Ridge using No. 50 Johns-Manville Asbestos ural Gray* No. 52, 9"xl8") /mark out color not Shingles--(color to be as selected). to be considered) Johns-Manville Asbestos Shin gles breaking joints with and entirely covering the starter course; after which proceed in the FLASHINGS Flash all chimneys, valleys, etc., with copper regular manner as with wooden shingles, or slate or other approved material. *ifhen Johns-Manville (/'l . I sixains Shinnies are to he hud in one color, omit the word "(hdorblende in the above .s//cJWficolions. Insert the desirctl color nhere reijuired. 177 CRMC-003541 Johns-Manville Service to Railroads In the jollotcing specifications reference is made to definite sizes and styles of shingles. fl here other sizes end styles are to he specified, insert color, size, style number and weather exposure as desired. (See pages 169 and 176 for necessary data.) American Method Standard. Asbestos Shingles (No. 3, No. 4, No. 5 or No. 6, } s" thick, smooth edge). Lay roof boards in the usual manner, breaking joints and nailing securely in place, with at least two nails at each rafter, leaving no loose ends. The roofing boards shall be well seasoned, of nar row width and uniform thickness; tongue and grooved preferred. Over the roofing boards lay one thickness of Johns-Manville Asbestos Slaters' Felt, laying horizontally with a 4-inch lap, and with 12-inch laps on ridges, hips and valleys. Apply %-inch thick by 1%-inch wide furring strip parallel with and hush with eaves, then, apply one course of No. 51 *(B), 9 x 18 inch starters at eaves lengthwise and parallel to same, overhanging the eaves about 1 inch. Then apply first main body course using No. 5 *(A) shingle, breaking joints with and entirely covering starter course; after which proceed in the regular man ner as with wooden shingles or slate, exposing 7 inches to the weather and fastening each shingle in place with two galvanized iron (or copper) needle pointed shingle nails. Never drive nails down tight, it is only necessary to drive them firmly. HIPS AND RIDGES Over the ridges and hips apply Johns-Man ville Asbestos Ridge and Hip Roll with not less than 3-inch lap, fastened in place with special ridge roll fasteners, or construct "Boston" (or "Chicago") Hip and Ridge, using No. 5 shingles. FLASHINGS Flash all chimneys, valleys,, etc., with copper or other approved material. Hexagonal Method Standard Asbestos Shingles (Nos. 60 or 70, %" thick, smooth edge). Lay roof boards in the usual manner, breaking joints and nailing' Securely in' place with two nails at each rafter, leaving no loose ends.; 'The roofing boards shall be well seasonedi of narrow width ahd uniform thickness; tongue and grooved preferred; Over the roofing boards lay one thick- ness of Johns-Manville Asbestos Slaters' Felt* laying horizontally with a. ;4-inch lap, and with 12-inch lap on ridges, hips and valleys. Apply a j4-inch thick by. J^-inch wide furring strip parallel with and flush, with eaves, then apply one course of No. 17 -(C) starters at eaves lengthwise and parallel to same, overhanging the eaves about 1 inch. Apply second starter course using No. 61 *(B) shingles at eaves lengthwise and parallel to same, breaking joints with and en- tirely covering the first starter course. Insert copper storm nails between abutting ends of shingles of second starter course. Cover balance of roof with No. 60-(A) 12"xl2", Johns-Manville Asbestos Shingles with copper storm nails protruding through hole in lower corner; these shingles to be laid with their side edges forming a 45 degree angle with the. eaves. Bend down copper storm nail protruding through the shingle, insert copper,storni nails between abutting corners of shingles; and securely fasten each shingle- in place' with;, two .galvanized iron (or copper) needle pointed' shingle- nails. Never drive nails down tight; it is only necessary to drive them firmly. HIPS iXD RIDGES 0ver `the ridges and hips 'apply Johns-Manville Asbestos Ridge and Hip Roll, with not less than 3-inch lap, fastened in place with special ridge roll fasteners leurvr-e FLASHINGS Flash all chimneys, valleys, etc., with copper or ot^er approved material, DIAGONAL METHOD The Diagonal Method (No. 9 or 12) Asbestos Shingles are applied in the same manner as specified for the Hexagonal Method. The foregoing specification will apply by substituting the desired size and style number. *Refer to sketches on pages 175 and 176 for identification of alphabetical references. 178 CRMC-003542 Johns-Manville Service to Railroads ] Flexstone Asbestos Shingles afford better service and greater fire protection because of their all-mineral, asbes tos rock fibre felt base. Johns-Manville Flexstone Asbestos Shingles (Slate Surfaced) "T TF.THERE for any reason the archi- VV tect prefers a flexible, slate sur- faced shingle Johns-Manville Flexstone Asbestos Shingles are recom- mended for any size bf building with a roof pitch sufficient to accommodate this type of roof covering. V * V: , Flexstone Asbestos Shingles are an improved, all-mineral form of the flexible slate surfaced shingle. There are two types of flexible slate surfaced shingles on the market today. One is the so-called asphalt shingle and the other is the JohnsManville Flexstone Asbestos Shingle. Although quite the same in surface appearance, the Johns-Manville Flexstone Asbestos Shingle is radically different and more desirable because of the basic raw material of which it is made. Flexstone Asbestos Shingles are Rock--Not Rags In a modern sky-scraper the strength and everlasting qualities of the foundation determine the durability, safety and usefulness of the structure; so it is with a flexible, slate surfaced shingle. A shingle cannot be better than its foundation. The felt base is its backbone, It depends for its useful life upon the re sistance of its felt to fire, time and weather. Therefore, the most important thing 179 CRMC-003543 Johns-Manville Service to Railroads about a roofing of this kind is the nature of the raw materials used in the manufac ture of the felt. The base of the ordinary asphalt shingle is a rag felt which is partly rags and in some cases partly jute, waste paper and other refuse material. It will burn to a cinder. The base of Johns-Manville Flexstone Shingles is the same asbestos rock fibre that is used in all Johns-Manville Asbestos Roofings. It is proof against rot, weather and fire. That is why Flexstone Asbestos Shin gles are superior. The natural durability --the practically indestructible nature of their asbestos felt base assures longer and more economical service and a greater de gree of fire protection. Flexstone Asbestos Shingles are better, more durable and- more fire-safe because of what is IN them, rather than because of what is ON them. And yet they cost little more than rag-felt shingles. As for the surfacing: On Flexstone Shingles the only function of the slate is to provide an attractive, colorful surface rather than a further protection for the felt. Asbestos felt needs no such protec tion. It is not dependent upon any kind of surfacing for its resistance to time, fire and weather. Flexstone Asbestos Shingles are attrac tive in appearance; moderate in first cost, easy to apply, fire-safe and they will not curl when properly applied. Flexstone Asbestos Shingles are fur nished with a surfacing of crushed slate in soft Red, a cool Green and a rich Blueblack. Johns-Manville Flexstone Shingles are approved by Underwriters5 Laboratories, Inc. ASBESTOS SHINGLES ARE THE ONLY FLEXIBLE COMPOSITION SHINGLES that take base rates of insur ance. Flexstone Asbestos Shingles have been labelled Class "B," the highest rating for this type of shingle. Many localities prohibit roofs of lower rating than Class "B." Made in (1) Flexstone Rectangular Indi vid u al Shinglessize 8" x424 shingles will cover 100 square feet of surface. Shipped in bundles of % square of 106 shingles, in cluding directions for application. Ap- proximate shipping weight: 230 lbs. per square. Mexstone Asbestos Individual Shingles, Sl2e 8 x 12^"- 6 lbs. of 1" large head galvanized nails per square required for application. (2) Flexstone Strip Shingles. A strip of asbestos slate surfaced felt 32" long by 10" or 12%" wide, .notched to represent four shingles. 112 strips: will cover 100 square feet. Shipped, in/bundles of y2 square of 56 strips, including directions for application. Strip shingles are quicker and easier to lay and require fewer nails. Approximate shipping weight 10" width 185 lbs., J-2%" width 240 lbs. per square. 4 lbs. of 1" large head galvanized nails per square required for application. Flexstone Asbestos Strip Shingles Size 32" x 10" or 12^". 180 CRMC-003544 Johns-Manville Service to Railroads Standard Specifications for Application of Johns-Manville Flexstone Rectangular Individual Asbestos Shingles (Size 8" x 123/") ROOF BOARDS Lay the roof boards in the usual manner, breaking joints and nailing securely in place with at least two nails at each rafter, leaving no loose ends. The roof boards shall be well-seasoned, of narrow width and uniform thickness; tongued and grooved preferred. MATERIALS Shingles shall be a heavy weight single thick ness of asbestos felt impregnated with asphalt, the weather surface to be covered with crushed slate, same to be Johns-Manville Flexstone Rectangular Asbestos Shingles (red, green or blue-black), size 8" x 1234", laid up in the following manner: ROOFING cut into strips approximately 8" wide and applied At the eaves apply sheet metal drip edge extending 4" each side of hip or ridge. Both edges (painted both sides), or a wooden strip, over shall be securely nailed with large head galvan hanging the eave approximately/ 54"- ized nails at least 1" long. These nails shall be Line the valleys with sheet metal, or Johns- spaced approximately 2" center to center and Manville Flexstone Slate Surfaced Asbestos Roof placed 34" from edge. . ing. If the.slate surfaced roofing is used it shall.. If the individual shingles are used application' be applied in two layers,- the first layer being 12" shall be started at either end of ridge and lower wide and the second or top layer, being 20" wide. : end of hip. Apply one shingle flush with main Lay the first, or. starting course, of shingles, body shingles, extending 4" each side of hip or vertically and butted- together, flush: with drip : ridge. Apply another shingle in the same man edge, thus making a solid strip along the . eave, ner and directly , over the first. Apply the next 1234" wide, r; vv r r-:. shingle in a similar manner, 4" from the butt of Lay another starting course,; directly; on top of the first shingle, fastening each shingle with two - the first and flush with -same;, starting- at the left : large head galvanized nails at least 1" long. These with a one-third width, shingle (254" X: 1234"), nails shall be placed 5" above the butt and 34" so 'that all. joint's will. be broken with first starting; from the sides, one either side of ridge or hip.' course. Space/these shingles :54" apart. > Apply succeeding: shingles in a similar manner* Start: the first main body course .at the. end .4" exposing 4" of each shingle- to the weather. . up, from the eave, with a whole shingle. Start the FLASHING .next course with - a two:-third : width shingle. Flash and counter flash, where necessary, with ,,(534. x 1234"). Start the third main body course with a whole shingle, and the fourth course with a one-third width shingle, and so on in rotation, sheet metal applied in an approved manner. SIDING breaking all joints one-third and two-thirds and Except as hereinafter noted, the specification spacing all main body shingles 34" apart. for applying roofing shall apply to Siding: All shingles shall have a weather exposure of 4". Allow J4" space around all doors, windows, etc., to permit shingles to be carried behind face NAILING boards, (these face boards shall be put on after Each shingle shall be nailed to the sheathing the shingles have been applied and shall lap the with two large head galvanized nails at least 1" shingles at least 2".) long. These nails shall be placed 5" above the The shingles shall be exposed 3" to the weather, butt and 34" in from the sides. nailing each shingle with two large head galvan HIPS AND RIDGES ized nails at least 1" long. These nails shall be After the main body shingles have been ap placed 4" above the butt and 1" in from the sides. plied, hips and ridges shall be covered with Johns- Secure the two lower corners of the exposed butt Manville Flexstone Slate Surfaced Asbestos Roof of each shingle with small copper brads or small ing or individual shingles. headed nails. 181 CRMC-003S45 Johns-Manville Service to Railroads Standard Specifications for the Application of Johns-Manville Flexstone Asbestos Strip Shingles Lay the roof boards in the usual manner, each cut-out, and one at the end of each strip. breaking joints and nailing securely in place with These nails shall be placed 5" up from the butt at least two nails at each rafter, leaving no loose and 54" in from the sides. Center nails shall be ends. The roof boards shall be well-seasoned, driven first. of narrow width and uniform thickness; tongued and grooved preferred. MATERIALS HIPS AND RIDGES After the main body shingles have been applied, hips and ridges shall be covered with Johns-Man Shingles shall be a heavy , weight single thick ville Flexstone Slate Surfaced Asbestos Roofing ness of asbestos felt impregnated with asphalt, the or individual shingles. weather surface to be covered with crushed slate, If the slate surfaced roofing is used, it shall be same to be Johns-Manville Flexstone . Asbestos cut into strips approximately 8" wide and applied Strip Shingles (red, green or blue-black), size extending 4" each side of hip .or, ridge, Both edges ; 10" x 32" or 12x 32", laid up in the following shall be securely nailed with large head galvan manner:- / ized nails at least 1" long. These nails shall be ROOFING : \ ] ' ; spaced approximately 2" center to center and At the' eaves apply sheet metal drip edge placed 54" from edge. ; ' {painted both sides), or a wooden strip, over If the individual shingles are used same shall hanging, the eaye approximately be cut from, the strip shingles and .application .. Line ., the , valleys: with' sheet metal, or . Johns- shall be started at either end of ridge and lower Manville Flexstone Slate Surfaced Asbestos Roof-: end of hip. Apply one shingle flush; with main ing, If slate surfaced rpofirig is used, it shall be applied in two. .layers, the- first layer being 12" body shingles, extending each side,of hip or 5 ridge. Apply another shingle in the saniemanner wide and the second, or top layer; being 20" wide. and directly over the first. Apply the next shin Lay the first^ .or starting course, of shingles gle in a similar manner 4'- above the butt of the flush with .the drip edge with the cutouts' up the first shingle and fasten with two large head gal roof, butting the. strips end to end. vanized nails at least 1" long. These nails shall Lay another starting course directly on top of. be placed 5" above the butt and 54" from the the first and flush with same, with the cutouts sides, one either side of ridge or hip, Apply suc down the roof, breaking joints. Butt the strips ceeding shingles in a similar manner, exposing 4" end to end. of each shingle to the weather. ; Start the first main body course at the end 4" up from the eave, with a strip from which half of the end shingle has been cut longitudinally. Start the next course above with a full width strip, and so on in rotation to break joints. All shingles shall have a weather exposure of 4". NAILING FLASHING Flash and counter flash, where necessary, with sheet metal applied in an approved manner. Siding--Note: Refer to same paragraph in spe cification for Flexstone Individual Shingle on page 181 and follow same instructions. In writing this specification, copy as part of it the "Siding" paragraph, making the following change: "These Strips shall be nailed to the sheathing with one nails shall be placed 4" above the butt and 1" large head galvanized nail at least 1" long above from the cutout." 182 CUMC-003546 Johns-Martville Service to Railroads Johns-Manville Rag-Felt Ready-to -Lay Roofings FHILE our Asbestos Ready-to-lay Roofings are the most satisfactory and economical .in. the long run, sometimes `the. matter of first cost, or nature; of the building, confines the choice to the. rag-felt .. type' of roofing, ; . . To meet this deuiaiid/; Johns-. . ManVille makes ragrfelt roofings, and makes them according,to-the same, high standards of manufac- . ture that govern the production of all its roofings. This assures the best return on the money in- ; vested no matter what type you buy. Johns-Manville Rag-felt Roof ings are made of carefully selected, clean rag - stock free from straw, jute and similar shoddy. This rag-stock is fabri cated into tough felts that are thoroughly saturated, literally soaked with a combination of waterproof ing, life-giving, natural asphalts, sealed into the felt by a heavy coating of the same natural asphalts on both sides.; The life of rag-felt roofing is largely dependent upon the character of the waterproofing used, so we choose only those that best resist the action of ;the sun' and wear and. tear Of weather; ;; In the selection Of: our asphalts we have no particular one to ex ploit. We compound and process asphalt materials in the light of the, most recent, up - to - date knowledge, without regard to what anyone else is doing or ex ploiting. We own no oil wells; we own no asphalt deposits; we are free to buy and use what experi ence teaches us is best. Therefore, the choice of the asphalts for roof ing is made with the primary ob ject of giving to the felt the max imum protection against time, weather and water, and to assure longest service with the minimum upkeep expense. 183 CRMC-003547 Johns-Manville Service to Railroads Where Used--How Furnished OHNS-MANVILLE Rag-Pelt Ready Roofings J are for use on roof decks where the pitch is 1%" or more to the foot. Made 32" wide and shipped in one-square rolls (108 sq. ft.) or two-square rolls (216 sq. ft.), except Slatekote Brand, which is shipped only in onesquare rolls. Pyramid Kaps or nails and cement, (as ordered), as well as directions for application are packed in each roll. Regal Brand The best grade of rag-felt roofing which will give splendid service. Extensively used for barns, sheds, outhouses, garages, freight car roofs, etc. Made in three weights: light, medium and heavy. Approximate shipping weight per square: light 35 lbs.; medium 45 lbs.; heavy 55 lbs. Slatekote Brand Made to meet the demand for an inex For use where an: ornamental surfaced,. pensive roof covering. It does not have , inexpensive rag-felt roofing is desired. the strength and durability of Regal Brand Made of a heavy sheet of rag-felt armored but . for the .conditions -under which ; it with a coating of crushed RED, GREEN should be used and ;considering .its cpsti.it . or BLUE BLACK slate, which is securely .will give very satisfactory; service. Made, imbedded into the surface of the felt. Has a in three weights, light, medium and heavy,': ; 2" selvaged edge to permit the proper join` Approximate shipping weight per square:, ing of laps:;: Made in one weight only ; light 35 lbs.; medium 45 lbs./heavy 55 lbs. shipping weight, about 85; lbs. per square. Pyramid Kaps The Pyramid Kaps are patented roofing fasteners which are far superior to nails and cement because they assure a more watertight and weathertight job. They are applied, end to end, along the entire length of all horizontal and vertical laps, thus providing a continuous, evenly distributed pressure at all points where the roofing felts are joined. This avoids the puckering, buckling and tearing away of felts due to imperfect cementing or where nails are driven into knot holes or cracks and the other faults of application some times experienced where nails and cement are used. These Kaps are designed for quick and easy application and their efficiency in ser vice eliminates 90% of leaks experienced with ready-to-lay roofings. See page 143 for complete description. These Kaps are only furnished when or dered, at slight additional cost. 184 CRMC-003548 Johns-Manville Service to Railroads Johns* Manville Roofing Accessories Johns-Manville Asbestos Fibrous Enamel An acid-resisting, bitumi nous coating, made of asbes tos fibre and natural asphalts and oils. It has the consistency of heavy paint or enamel and is furnished in two colors, black and red. It produces a tena cious, durable, protective film, thus seal ing the metal or roofing from the weather and preventing rust, corrosion and unnec essary upkeep expense. Due to the use of Asbestos' fibres, it is remarkably elastic, expanding and con tracting with the/surface and avoiding chipping and flaking common to ordinary paints, .assuring longer and;better service. Used on exposed steel work, bridges, iron electric railway poles, street lampposts, skylights, outside stairways, fireescapes, cornices, agricultural imple ments, contractors' equipment. In fact, every place where metal or composition roofing is exposed to the weather or to other corroding influences it should be covered with Fibrous Enamel. Easily applied; will not check in dry weather nor crack in cold. Covering ca pacity, 100 to 150 square feet , per gallon, varying according to the surface to which it is applied. Shipped ready for use in containers the same size as shown for Black Regal Roof Coating. Johns-Ma nvi 11e Regal Roof Coating ; An impervious^ durable, protective coat ing for : roofings /generally -- especially composition felt, tin, iron or other metal. Also for the protection of steel work. Made of pure asphalt and asphaltic oils absolutely free from coal tar pitch. For this reason it retains its waterproof qual ities much longer than other similar pro ducts, making it most economical and satisfactory. It preserves the life of felt roofing be cause it penetrates the body, fills the voids and restores its original waterproof and weather-proof qualities and what is of es pecial importance, it maintains this con dition indefinitely. On metal roofs, lead ers, gutters; etc., it fills; fust spots, pin holes, seams, etc/; It is unaffected by con traction or expansion, gases or alkalies. Will not run in hot weather nor crack in cold.. Made in black, light red, and light green. Furnished in 1, 2, 3 and 5 gallon cans, 25 and 50 gallon drums in the Black. Colored coatings are furnished in 1 and 5 gallon cans and in half and full barrels. Covering capacity 150 to 200 square feet per gallon, varying according to the smoothness and porosity of the surface. 185 CRMC-003549 Johns-Manville Service to Railroads Johns-Manville Asbestos Slater's Felt N insulating felt made of asbestos A fibres, impregnated with natural * asphalts. Used as an insulating As it contains no vegetable, animal or organic material it is rot and weatherproof and will and waterproofing material between roloafst indefinitely. Made 32" boards and shingles, slate, tile, etc.; also wide and shipped in 3-square between siding and shingles and similar rolls. Weight approximately building insulating purposes. 14 lbs. per square. Johns-Manville Asphalt Roofing Cement For the application of built-up roofing or to re-waterproof and provide a weather proof surface finish for old roofing felts; for the laying of patch strips or full sheets of felt in general roofing repair work, where conditions demand a mop ping of hot asphalt. Johns-Manville Asphalt Roofing Ce ment is shipped in full, one-half and onequarter drums, weighing approximately 400, 200 and 100 lbs., respectively. As shipped it is a solid, hard mass which is melted in kettles at the job and applied hot. Johns-Manville Asbestos Roof Putty A roofing cement used to stop leaks,'; due to holes in tin, zinc, slate,: shingle, wood or .composition roofs* gutters or; flashings; also for pointing up around leaky chimneys, skylights, etc. ;i iiv fact, may be used for any job where leak-proof. repair cement is desired. Shipped ready for applica tion in black, red and gray in 1, 2, 3 and 5 lb. cans, 25, 50,100 and 200 lb. containers. Johns-Manville Cold Water Paint (For Interior Use) Johns:-Mahvi;lle- White Cold Water, ing for all interior building and, other Paint makes a durable, fire-resisting coat- surfaces; brick, stone, concrete, plaster or Wood. For the interior of train sheds, factories, warehouses, garages, docks, freight houses, interior squash, ten nis and handball courts, gymnasiums, ho tels, clubs, hospitals, office buildings, stables, etc. Furnished in white and sixteen tints, which can be intermixed to obtain any other desired tint, or can be deepened in tone by adding a small portion of ordinary After an application of Johns-Manville Cold Water Paint. tinting colors. 186 CRMC-003550 Johns-Manville Transite Asbestos Wood 187 CRMC-003551 Johns-Manville Service to Railroads Fresh Pond Road Station, Brooklyn Rapid Transit System. H. J. Kolb, Engineer of Design, Brooklyn, N. Y. Johns-Manville Transite Asbestos Wood as interior paneling. Johns-Manville Transite Asbestos Wood OHNS-MANVILLE Transite Asbes - Johns-Manville Transite Asbestos J tos Wood is a (flat) rigid, all-mineral Wood has all the desirable properties of material for general' use in permanent, natural wood arid sheet metal but it is su fireproof interior and exterior construc- perior to them. Unlike natural .wood ; 'tion, in place of natural-wood,;plaster, wall- Transits is not inflammable. It cannot board,, stucco, or sheet metal. . burn because it is actually a sheet of stone Johns - Manville. Transite Asbestos --neither will it rust, dent or buckle like : Wood is made of asbestos, fibres and Port- sheet metal.-r And .Transite never needs ... land, cement united under , hydraulic-pres paint or any other surface protection sure into, dense, homogeneous, structur which eliminates the expense and bother ally strong sheets of various sizes and of maintenance so necessary for natural thicknesses. wood and sheet metal. Easy to Apply Johns-Manville Transite is easy to ap ply. It is comparatively light in weight and can be handled in the same manner and with practically the same ease as any hard wood. It can be cut and worked with ordinary tools and fastened with nails, screws or bolts. It is unaffected by water, alkali and most acids. Sudden or extreme changes of temperature do not affect it in any way; it actually becomes tougher with age. It has many of the physical character istics of ordinary wood, except that it is harder and takes a higher polish. It has a fibre strength under transverse loads of 3,500 pounds per sq. in., being about two-thirds as strong as ordinary wood. 188 CRMC-003552 Johns-Manville Service to Railroads Attractive Appearance Transite has a neat, attractive appear ance. Its smooth, gray surface permits its use just as it comes from the factory but where it is necessary to have Transite match the surroundings it can be painted, varnished or grained as desired. In every way Transite Asbestos Wood is the ideal material for walls, partitions, panelings, ceilings, fire doors, roofing or siding, because it provides the maximum of fire protection and durability with the minimum of construction thickness. Johns - Manville Transite Asbestos Wood is approved by Underwriters' Lab oratories, Inc. Its fireproof nature, its durability, its service economy and many other desirable qualities recommend it strongly to archi tects and engineers for use in railway sta tions, public buildings, shops, garages and factories for many of the purposes sug gested in the list below. How Furnished Transite Asbestos Wood is made in two finishes -- STANDARD and SPECIAL, Standard Transite is reasonably smooth on both sides. Special Transite is perfectly smooth on both sides and is preferable for use where precise and uniform thickness throughout is desired. Both kinds are furnished in sheets 36" x 48", 42" x 48" and 42" x 96" in the thicknesses shown below, The finish of the- %" thickness is slightly different--it is reasonably smooth on one side and slightly pebbled on the other and is oniy furnished in the 42" x 96" sheet when specially ordered, _ Where it may be desired to use a flat instead Of a corrugated material, Special Lipped Transite is .recommended. Details of application of this material will be found on page 191. Thickness: : ..., . .} s" Approximate. Weight per Sq. ft. lbs., 1 '1.7 W.. : H" ' : -2-1 - . 2.? > 3.4 i. h" - . .1" . Hi". ' 2.' . - 4.0 . 5.3 . 7.6.. 10.1 13.0; . 15;. 7 ; 18.5 , , 21.0 .. A Partial List of Uses in Prominent Industries Automobile Manufacturers Acid ducts and openings Automobile foot boards . Baffles Ceilings, walls, partitions, sid ings: walking surface over enameling ovens: over rail road switching tracks in ware houses Dry kilns Furnace dampers and doors Smoke flues and breeching lin ing Ventilators Chemical Industry Acid ducts and openings Bus-bar barriers and spacers Ceilings, walls and partitions Cabinets, boxes and . similar equipment in laboratories, etc. Fume Hoods General Fireproofing Furnace dampers and doors Smoke flues and breeching lining Table; sink tops and hoods Ventilators Manufacturing General Drying .and enameling ovens Baffles--Over oil stills; in stor age battery dry olate kilns; between Burton stills Ceilings, walls and partitions Canopies over loading platforms Cabinets: boxes and similar equipment Dry Kiln Partitions Fire doors General Fireproofing Fireproof Partitions--Office and Industrial buildings Furnace dampers and doors Fireproofing Elevator shafts Powder Houses Smoke flues and breeching lining Storage Bins Siding and roofing Oil and Gasoline Storage Rooms Ventilators Oil Refineries Ceilings, walls and partitions Curtain walls between condens ers in refineries Cabinets, boxes and similar equipment Dampers General Fireproofing Furnace and Flue dampers and doors Fire Barriers Housing for Insulated Pipe Lines Ventilators Railroads Ceilings, walls and partitions Canopies over stations and load ing platforms General Fireproofing Under upholstering of car seats where heating coils are in stalled Portable houses Smoke jacks Ventilators Smoke Ducts Rubber and Rubber Goods Manufacturers Ceilings, walls, partitions Curing rooms General Fireproofing Furnace dampers and doors Laboratory Table tops Ventilators Textile Industry- Acid ducts and openings Bins for storage of hemp, saw dust or textiles Ceilings, walls and partitions Fire doors General Fireproofing Smoke flues and breeching lining Table tops Ventilalors 189 CRMC-003553 Johns-Manville Service to Railroads Some typical uses of Transite As bestos Wood un der widely dif ferent conditions. Top right and left: As used for oil switch com partments. Left center: As in terior sidewalls. Center: On walls and ceilings of railroad main dining room. Right Center: On walls and ceiling of underground passageway. Bot tom: As exterior siding. 190 CRMC-003554 Johns-Manville Service to Railroads el Figure'1. Sketch' of -Transite Asbestos Wood Roofing showing specialJip.' construction. Figure 2. Details of ridges, lining of gutters and valleys, etc., in connection with the application of Transite Asbestos Wood Roofing, special lip construction. 191 CRMC-003555 Johns-Manville Service to Railroads ASB.T&DU Panel / Voo> EVRJLUfG ASB.WC3D> BaTTEH' ELEVATION OP JIJ>riVAU_- E)XOCK.IK<JWodJ> RAIL. SheaTHIhg- LOTTGm/JMAL Stvwihg ASh ya . K-AS5- WCDJ .) . PAttLU_ Note- * A3Bt5T05 VC5*r>. SIZE* SH-tlPTS ARfr Asb . Wqd> Yaiv?i. . TAIL 4E"x4-e" A1^J> 3G"*Ae" Casb.Vgdj* mat also xr 5tCT10H XrSX-> TOR. ^XTE-5J05l flCDR CtILl'KG VIE-w PAht-LS Alf> HALF IIKbPRJ ET-KfcCTS0 ' Figure. 3. Application.'of Standard Transite* Asbestos Wood as. wall panels with/'batten strips. Figure 4. Application of Standard Transite Asbestos Wood as a paneling for ceilings. 192 CRMC-003556 Johns"Manville Service to Railroads Johns -Manville Transite Asbestos Wood Smoke Jacks OHNS-MANVILLE Transite Asbestos usual conditions, special designs will be J Wood Smoke Jacks, being made of an all-mineral material--Asbestos Wood furnished. The ventilated type of jack is to be pre --will withstand gas, sparks, frost andferred as this type will permit the escape moisture far better than wood or metal through the ventilating space of any jacks. Both wood and metal jacks require smoke or gases which may, due to impro frequent painting; in the case of wood per spotting of the locomotive, fail to be jacks, to make them somewhat fire resist drawn out through the stack. ant, and also to slow up the inevitable and The lightweight of these jacks, coupled rapid decay. The metal jacks must be with their simplicity of design, makes heavily blanketed with paint to guard them easily assembled and erected, and against the destructive forces of the ele avoids the necessity of special roof sup ments outside of the roundhouse and the ports. gases pouring from the stacks of the loco The various standard jacks are illus motives inside the; houses vjbhhs-Manville trated on the followingTages.,' ' Transite Asbestos Wood .Smoke jacks re-, quire nb painting; hr. 6ther upkeep,\ Their first cost is their fifial tbst.h.AJA We have deyeloped^tbis line-to a point where we can ship anw{dbsiredrnumbeAbf ;hur ten;standar.d-;jaqks\with.';:prat^ delay, and when; necessary to, meet un Johns - Manville Transite Asbestos Wood Smoke Jacks and Johns-Manville Asbestos Built-Up Roofing on round house of Central Railroad of New Jersey, Communipaw, N. J. 193 CRMC-003557 Johns-Manville Service to Railroads Johns -Manville Transite Asbestos Wood Smoke Jack, Type "G (Patented) The type "G" Smoke Jack illustrated here, is a low priced and popular style of Jack which has been in use on various railroad systems under all conditions of service for a number of years. It is light in weight, easily installed and requires prac tically no attention after being erected. The illustration and bill of material e0W*, U to*i Cast A*ft* \ Co*tr,hepds fa? . jcr&r* Witn cover types "G-l" and "G-2." For type "G-3," which has a 10-foot stack, an extra 2-foot stack section and collar are fur nished. BILL OF MATERIAL Part Description Quantity Per Jack fyp e G -No. 2 G -No- 1 A Transite Cap, with reinforcement .... 1 B Transite Stack Piece ......................... 2 C Transit e Stack Piece ........................ 2 F Cast Iron Flashing i 2 2 Angie (4 pieces) G Cast Iron Collar (4 pieces) .................... H Transite Hood Piece J Transite Hood Piece K Transite Hood Piece L Transite Hood Strip M Transite Hood Strip 1 1 2 2 2 2 2 1 1 2 2 2 2 2- P Hanger .Irons, ,^"x .2"x5'-6" or to'suit 4 4' R, ..Iron : Cap - Supports, 4 4 .. S../ Plain ..Lag- ; Screws/. 32' V 32 Plain Machine .Bolts,' . .' .%.','x2''; (-1- washer) .16 Vy -Round ,' Head '; Iron .--.yStoveBolts, .-%"x - ' 1.5 - .. .... 130 . . 130 A W ..Round. Head ; Iron \ASt.ove; -.-Bolts,' %"-x vv-;i2^.=-'-;:-;V-L iVA-Av//-.- 142 : 110 i xr . Disked Washers: for. Bolts . ..: 544 480 ' Cement -. . 50 lbs. 40 lbs. Galvanic Varnish.... }A gab Vz gal.. Opening in roof sheath ing should be :n accord ance with the following dimensions: r i NOTE:--When ordering pa'rts: state part numbers as shown. All identification marks plainly stamped as shown. IMPORTANT:--Protect body and threads of bolts and cover ail bolt heads and nuts with cement. Paint cap supports, hanger irons, iron hood to stack collar and flashing angle with two coats of Galvanic Varnish. Opening in roof timbers should be 28"x51". Line No. 1 2 3 No. Type G-l G-2 G-3 A 4'0" 8'Q" lO'O" Weight (in place) 1265 lbs. 1445 lbs. 1605 lbs. 194 CRMC-003558 Johns-Maiwille Service to Railroads Johns-Manville Transite Asbestos Wood Smoke Jack, Type "H" (Patented) The type "H" Smoke Jack is similar to type "G,'? with the addition of a roof stack, which makes it a ventilating type. This ventilating feature provides for the escape from the round house of smoke or gases which may, due to improper spotting of a locomotive, escape from the hood. This Jack is installed in the same manner as the type "G," requiring no special bracing of the roof timbers. Quantity Part Description Per Jack A Transite Cap with reinforcement i B Transite outside stack piece......... 2 C Transite outside stack piece......... 2 D Transite outside stack strip......... 2 E Transite outside stack strip......... 2 F Iron stack feet, 3^"xli4"x6"xl8" 6 G Cast iron collar (4 pieces).............. 1 H Transite Hood Corner Piece......... J Transite Hood Corner Piece......... K Transite Hood Side Piece............. 2 2 2 L Transite Hood Strip........................... 2 M Transite Hood Strip........................... 2 N Transite Inside Stack Piece........... 2 O Transite Inside Stack Piece........... 2 P Iron Hangers, *4"x2"x5'-6" or to suit ........................................................... 4 R Iron Cap Supports, 34"xl5-T'x7J4" x33" .................................................. 4 S Plain Lag Screws,54"x254" ... 28 T Plain Machine Bolts, A4"x2" (1 washer).........;.................. 16 V Round Head Stove Bolts, y^"x\y2" (iron)- A .;........ 284 W Round Head -Stove: Bolts, :$"x2" (Iro.n) _____ ... ..... . ............ 42 'X Dished Washers for.- 44" Bolts.: 652 Cement . 1. / 50 lbs. . Galvanic' -Varhish .4. .... .... 54.gak. > Bex bt/rii vp (e> to svppe't arts.* staot Cere* fttoss ef 'ey, -------- Weight in place--1615;lbs.' '' NOTE:--When ordering- parts Estate, part- num bers as shown.;y '' 'V All identification, ma'rks.'pjaiiily..stamped as shown. IMPORTANT (-^Protect.body and threads ofbolts and cover alb bolt .heads and nuts with ce ment. Paint cap supports, hanger irons, iron hood to stack collar and flashing angle with two coats Galvanic Varnish. , / Opening in roof' timbers should be 28"x51". Opening in roof sheathing and box should be in accordance With the cut below: Sectie* to -c 195 SecTion ot foot Line. CRMC-003559 Johns-Manville Service to Railroads Johns-Manville Transite Asbestos Wood Smoke Jack, Type "J" (Patented) The latest developments in Smoke Jack design have been included in the type "J" Smoke Jack. It has been built to meet the requirements imposed by the large loco motives now in service. The hood is de signed with an angle which will mater ially assist in disposing of the greatest amount of smoke consistent with the stack dimension. The round stack pro vides for the greatest possible smoke space, with the minimum opening in the roof. The illustration covers types "J-l" and "J-2." For which has a 10-foot stack, an extra 2-foot stack section and collar are furnished. BILL OP MATERIAL Quantity Per Jack Part -- A AB AC B BC C G H HA J JA K. KA KB KC b: ~. Description Type J-No. 1 J-No. 2 J-No. 3 Cap m 2 pieces, with cleat.............. I Stack Section........................................... I1 1 Stack Cleat................................................ 1 Stack Cleat..-.......... .............................. Stack Section........................................... 1 11 1 Stack Cleat. ..................... .. -................. 11 1 Cast Iron Hood to Stack Collar.. 1 1 Hood Corrier Section (Transite)., 2 22 Hood Corner .Section (Transite).. . 2 . Hood Corner Sectiori (Transite)..' 2 2 2 2 2 Hood Corner Section (Transite).. 2 22 Hood Side. Section (Transite) 2 2 .2 Hood Side Section (Transite)-... 2 2 .2 Hood Side. Section (Traiisite).... 2 2 2 Hood Side Section (-Transited... 2 22 Hood Side;, Cleat. (Transite) v.-.1 (; 2 " 2 ' M MAP T --* -- Hood End 1 Cleat '(Transite) .;. 2 . Hood End ' Cleat- (Transite):.;.... 2 Ho.od Side Cleat .i.Tratvsite),;l .: 2 Hood Side , Cleat (Transite); . ... ?, Flashing Angle, (Casr .Tron) :3' pcs. 1 Round Head"- Iron ' Stove '. Bolts. (1Vi" x f(i'(.:-.....V..Av..T.-..: 339 ' ;2 2 ' '2: 2 1 384: 2 2 2, '' 2 1 428 ---- . Round Hedd-, Iron'.. Stove: Bolts. 2": X ............. 72 ' '72- ' 72 ' Lag Screws, 2" x. ...:... 28 28 26 --- . Machine Bolts; 2" x A"............. 16 16 16 Dished Washers....... .. ---- Cement S22 912 1020 . 60 lbs. 70 lbs 75 lbs. ' -- Galvanic Varnish'. ... i ... i. A ga: Iron Cap Supports, Ya" x 1!4" x 7YY` x 33"................... ........... ........... 6 6 G Hanger Irons, U" x 2" x 9'-6".. 4 4 4 NOTE:---When ordering- parts state part letters as shown. All identification marks plainly stamped as indicated. IMPORTANTProtect body and threads o{ bolts and cover all bolt heads and nuts with cement. Paint cap supports, hanger irons, flashing angle and cast iron hood to stack collar with two coats Galvanic Varnish. Opening in roof timbers to be 46"x4G". Opening in rool sheathing should be 41" in diameter. Line No. Type No. 1............................... J--No. 1 2............................... J--No. 2 3............................... J--No. 3 196 A 4'-0" 8'-0" lO'-O" Weight (inplace) 2060lbs. 2315lbs. 2570 lbs. CRMC-003560 Johns-MaimUe Service to Railroads Johns-Manville Transite Asbestos Wood Smoke Jack, Type "K" (Patented) The type "K" Smoke Jack is identical with the type "J" Jack, with the exception that it has a roof stack--thus providing a ventilating feature. There are occasions when a locomotive is improperly spotted and the smoke escapes from the hood. With this type of Jack such smoke is drawn out through the space provided between the inside and the outside stack. BILL OF MATERIAL Part -- Description Quantity Type K-No. 1 K-No. 2 Cap in 2 pieces, with cleat-- (Transite) .................................... 1 1 A Stack Section, Inside (Transite) 1 1 AB Stack Cleat, Inside (Transite) AC Stack Cleat, Inside (Transite) 1 1 1 1 B Stack Section, Inside (Transite) 1 1 BC Stack Cleat, Inside (Transite) 1 C Stack Section, Inside (Transite) 1 1 1 G Cast Iron Hood to Stack Collar (4 pieces).............................. 1 1 H HA J JA K Hood Corner Section (Transite) Hood Corner Section (Transite) Hood Corner Section (Transite) Hood Corner Section (Transite) Hood Side Section (Transite) 2 2 2 2 2 2 2 2 2 2 KA Hood Side Section (Transite) 2 2 KB Hood Side Section (Transite) 2 2 KC Hood Side Section (Transite) 2 2 L Hood Side Cleat (Transite).. 2 2 M Hood End Cleat (Transite).. 2 2 MA Hood End Cleat (Transite).. 2 2 P Hood Side Cleat (Transite).. 2 2 T Hood Side Cleat. (Transite) .. 2 2 W Stack Section, Outside (Tran- site) ......................:......... 11 wx Stack Cleat, Outside (Transite) 1 1 wz Stack Cleat, Outside (Transite) 1 1 X Stack Section, Outside. (Tran- site)' ............. .(/'.;.. ... 11 XY Stack Cleat, Outside (Transite) 1 1 Y Stack Section, Outside (Tran- site) ............. -\;;... 1. 1 YZ Stack Cleat, Outside -(Tran- site)................ A ; iv. ... 1 1 .. Z Stack Section, : Outside . (Tran- . site) ......... ..................................... 1 1 -- Flashing Angle (Cast' Iron) 3 pieces '............ . :,.. __ Round Head Iron Stove Bolts, 1 1 WxM" ......... 394 __ , Round Head Iron Stove Bolts, 468 2"*H" ........... ................................. 56 56 __ Lag Screws, 2"x*.<" .......... 32 32. -- Machine Bolts, 2"x54" ......... . 16 16 __ Dished Washers ........................... 904 1048 __ Cement ............................... ............... 75 lbs. 85 lbs. -- Galvanic Varnish ......................... Vz gal. V, gal. -- Iron Cap Supports, Wxl!/>"x 66 -- Hanger Irons, J^"x2"x9'-6"... 4 4 NOTE:---When ordering parts state part letters a shown. All identification marks plainly stamped as indicated IMPORTANT:--Protect body and threads of DoltS and cover at bolt heads and nuts with cement. Paint cap supports. hanger irons, flashing angle and cast iron hooc to stack collar with two coats Galvanic Varnish Opening in rool timbers to be 4G"x4G". Opening in roof sheathing should be 41' in diameter. Line No. l.. ........................... 2. . ........................... Type No. K-No. 1 K-No. 2 A 4'-0" 8'-0" Weight din iilncel 2295 lbs. 2620 lbs. 197 CRMC-003561 Johns-Manville Service to Railroads Johns -Manville Transite Asbestos Wood Smoke Jack, Type "L" (Patented) The type "L" Jack is of the same gen eral design as type "J," but has a shorter and lower hood, so that it can be used in engine houses having too low a roof line to permit the use of the type "J." BILL OF MATERIAL 1I Part !-- Description Quantity Per Jack Cap in 2 pieces, with Cleat.... 1 |A B IC Stack Corner ...................................... Stack Corner ...................................... Stack Corner ...................................... 1 1 1 j AB Stack Cleat .......................................... BC Stack Cleat .......................................... ' CA Stack Cleat .......................................... 1 1 1 G H J IK Hood to Stack Collar (4 pieces) Hood Corner ...................................... Hood Corner ...................................... Hood Sides ......................................... 1 2 2 2 KA Hood Sides ......................................... 2 L Hood Cleat .......................................... I M Hood Cleat .......................................... 2 2 T Hood Cleat ......................................... 2 ' -- C. I. Flashing (3 pieces) ............. 1 i -- Hanger Irons, *4"x2"x6'................ -- Cap Supports, 34"xl'.j"................. 4 6 -- R. H, Stove Bolts, M'xl}4".... 252 -- R. H. Stove Bolts, $4"x2"........... 62 -- -.Dished Washers, Y&'...................... 648 : -- Machine. .Bolts, y2"x2".................. 16 . -- Lag Screws,. 1<"x2.K"................ 28 -- Cement .......... .................. 50lbs -- Galvanic Varnish ...:........... lA gal. Weight in place--1-775 lbs. NOTE:--When ordering parts state part letters as shown. All identification marks plainly stamped . as shown. When more than one jack is furnished, parts will be numbered in addition to usual letter ing; via.--1 A, 1 K, etc. All parts bearing same number must be used on same jack. IMPORTANT:--Protect body and threads of bolts and cover all bolt heads and nuts with ce ment. Paint cap supports, hanger irons and flash ing angle with two coats Galvanic Varnish. Open ing in roof timbers should be 46"x46". Opening in roof sheathing should be in accordance with the cut shown below: 198 CRMC-003562 Johns--Manville Sendee to Railroads Johns-Manville Transite Asbestos Wood Stacks and Caps Johns-Manville Transite Asbestos Wood Ventilators Painting-, and similar forms of. maintenance are unnecessary with-these ,two products. . ;Being--made of Transite Asbestos Wood their all-mineral com position defies weather and acid fumes. They never need painting and actually grow -tougher with age which is the exact reverse of experience with wood or iron products. OHNS-MANVILLE Transite Asbestos OHNS-MANVILLE Transite Asbestos J JWood Stacks and Caps,are made in all sizes and for all purposes^ The mater ials used in the construction of these stacks, Wood Ventilators are adaptable wher ever the common wood, iron and cop per ventilators are installed. They are es is the same as for Transite Asbestos^Wood pecially recommended for engine houses, Smoke Jacks described in detail on pages gas and power houses, laboratories, fac 193 to 198. tories, etc., where it is essential to select They are used principally over forges in a material that will withstand the action machine shops, on gas houses and chemi of acid and alkaline fumes and gases. cal laboratories, or as flues for conducting These ventilators are constructed of the acid and alkaline gases, as they are quite same material as Johns-Manville Transite impervious to such destructive agencies. Smoke Jacks, described on page 193, that We are in a position to quote on Johns- is, a composition of Asbestos Fibre and Manville Transite material made to any Portland Cement--recognized as the most special shape for stacks, flues, hoods or durable and time-resisting materials used ducts. in engineering. Prices upon application. Prices upon application. See next page for dimensions, etc. 199 CRMC-003563 Johns-Manville Service to Railroads Johns-Manville Transite Asbestos Wood Ventilators (Continued) DESCRIPTION - The following tabulation describes those, parts of ' "/..' the. .ventilators illustrated above which are marked .;'-. with similar letter references: M..Johns-Manville Transite Asbestos WoodStack N . .......... .. .. .Johns-Manville Transite Asbestos Wood Guard . P.. ..,.... Johns-Manville Transite Asbestos Wood- Upper Cone R.....Johns-Manville Transite Asbestos Wood" Lower' Cone :S ......... ..........Angle Iron Ventilator Support T.. ................ .Bar Iron Cap Support U....... ...................... . .Bolt and Separator Cap Support". W..................................Round Head Stove Bolt X......................... . . . Lag Screw Type "D" No. 1 2 3 4 5 Type "E" No. 11 12 13 14 15 TABLE OF DIMENSIONS IN INCHES ab cd ef g 10 20 17 14 7 1 51; 18 36 31 21 10V2 iK 7 24 49 42 30 14 2 9 30;:: 61 54 42 14 5 9 36 74 64 48 21 3 14 Outside diameter of stack. h 2T 4 3K 5 5 7 j 3 5 6 8 10 k K K K K K 200 CRMC-003564 Johns -Manville Keystone Hair Insulator 201 CRMC-003565 Johns-Manville Service to Railroads Johns -Manville Keystone Hair Insulator A Necessity in Qood Building Construction HE increasing value of floor space Tin all types of buildings demands that walls, floors, partitions, etc., be of minimum thickness. One of the evils and discomforts which come with such space conservation is the annoyance due to the great increase in the noises transmitted through such parts of the building. Also the loss of comfortably cool rooms in summer and increased coal con sumption required to properly heat such rooms during the win ter months. All this is due directly t o the reduces to the minimum the disturbing sounds generally transmitted through thin, hard walls, floors, ceilings, etc., but which also provides an efficient barrier to heat and cold. Johns-Manville Keystone Hair Insula tor efficiently meets this three-fold re quirement, not only adds to the privacy but greatly increases the comfort of the ten ant or owner. It nets a cumulative return on the investment by the yearly savings in fuel required to properly heat the structure. practically negligible ; heat, cold and sound resistance of such con struction and the ma-. terials used. . These objections can illustration shows typical struc- While Keystone Hair Insulator is particular ly adapted for heat and cold and sound insulation in private dwell- be easily overcome by . Hair insulator. mgs, hospitals, dormi- the adoption of a sirn- ; : y. jtories, etc., it will be pie yet effective remedy--building insula- . apparent that practically - every type of tion with johns-Manville Keystone Hair . building can be made more comfortable in Insulator. Progressive, architects: arid summer and still more comfortable and . owners have always insisted upon build- -easier to heat in winter if it is protected . ing insulation---insulation which not only with Keystone. Building Insulation An Investment in Comfort and Economy Efficient wall, floor, ceiling and roof insulation is an investment--not an ex penditure. It pays dividends every year it is in service in the added comfort and greater operating economy it af fords. . But what is proper and efficient insula tion? How can owner, engineer or archi tect differentiate between the good and bad in the various kinds of insulation that are offered? Clearly, the best insulation must answer certain definite requirements and because Keystone measures up squarely to the conditions for which it is recommended we offer it as the best insu lation and stand ready to prove our claims. 202 CRMC-003566 lilaiyiisit Johns-Manville Service to Railroads Why Johns-Manville Keystone Hair Insulator Is Superior O meet the exacting demands of the majority of the average "insulations" Tmodern construction practice a build can be quickly rejected. They are un ing insulation must be sanitary, fire- clean, furnish refuge for vermin, are high resisting and durable or it is a menalyceinflammable, rot, "pack down" or have to health, to safety and little or no insulating to your investment. value because they are It must be durable too tightly packed or because deterioration are not adaptable as and the necessity for replacement in a few years not only mean annoyance and expense but such work is prac tically impossible after the building has been completed and occu good insulation. Johns-Manville Key stone Hair Insulator because of its construc tion and the materials of which it is made has none of these draw pied. backs, yet it possesses And what is more important--it must be v.as11 y more. than. a Franklin High School, Seattle,. Wash., Edgar Blair,- . Architect. Johns-ManvilleKeystone'Hair Insulator is used for .prac-. tically/cvery type of building. all the virtues claimed for the ordinary insu lations. Not only that mere "filling." It must but the user can get insulate~effectively by offering the maxi just the proper insulation for his con mum resistance to heat,- cold, dampness ditions. The insulating material used in and sound. d:. Keystone^chemically cleansed cattle hair And it certainly ought not to be readily --is furnished with plain building paper, inflammable or carry . flame. asphalt saturated or. asbestos paper on How many insulations meet .such rigid one or both sides according to the re requirements? ; Investigation shows that quirements. Actual Savings in Coal by the Use of Johns-Manville Keystone Hair Insulator The illustrations on page 207 show typi cal methods of outside wall construction with Johns-Manville Keystone Hair Insu lator installed as a heat and cold insula tion, in comparison with the same forms of construction without insulation. No. 1 shows wall without insulation. Nos. 2 and 8 show application of one layer of Johns-Manville Keystone. No. 9 shows the application of two layers of Keystone. As an example of the efficiency of Key stone Hair Insulator, the rate of heat transmission through No. 2 is only .182 203 CRMC-003567 Johns-Manville Service to Railroads B.t.u. per square foot No. 1 under the same of exposed wall surface conditions. Therefore, per hour, per degree there is less than half temperature difference of the heat loss through between air inside the a wall insulated with building and air out two layers of Johns- side, while the loss Manville Keystone through the same con Hair Insulator as struction (No. 1), with shown in No. 9 than out Johns-Manville through an uninsulated Keystone, is .28 B.t.u. wall, as shown in No. 1. under the same condi tions. Translating these figures into pounds of coal saved by the use of Residence of N. Roy Shambleau, South Bend, Ind. which was insulated with Keystone. Johns-Manville Keystone Hair Insulator is ideal for the moderate size residence. With No. 9 the ac tual saving in coal is 348 pounds for every 100 sq. feet of exposed sidewalls during a heat Keystone Hair Insulator in outside walls, ing season of 210 days, with an average shows an actual saving of 236 pounds of temperature difference of 40 F. coal for every 100 sq. feet of exposed side- The net results to the user of Johns- walls during a heating season of 210 days, Manville Keystone Hair Insulator are with an average temperature difference of such a saving in coal consumption as 40 F; should pay for the material in a short The rate of heat transmission through. time; maintenance of more even tempera- No. 9 is only .135 B.t.u. per sq. foot per tures in his building; cooler in summer, deg. temp.: difference per hour, as com- warmer in winter and more comfortable pared with the loss of .28 B.t.u. through and quiet at all times. Description of Keystone Hair Insulator Johns-Manville Keystone Hair Insula-.: in weight than most other insulating ma tor consists of a heavy layer of thoroughly cleansed cattle hair securely fastened be tween two sheets of protective paper, es pecially chosen for the conditions under which the insulator is to be used, as will be noted under the full description of brands, on page 205. The body of Keystone is the best grade of cattle hair, treated chemically to render it vermin-proof and odorless. It will not dry out, split, pack down or rot with age and lasts indefinitely. As it merely shriv terials and therefore easier to handle. It is uniform in thickness throughout and be ing flexible, fits odd corners making it easy to apply. Packed in bales 3 feet wide containing five hundred square feet with the edges bound and beveled. It spreads on surfaces as easily as paper or wool felt and is, therefore, easily applied. The bound and beveled edges allow a 1" lap instead of hav ing to be butted, thus assuring tighter and els when it comes in contact with fire, it more effective application. Excello Brand, will not carry flame. page 206--furnished in sheets 3' x 8'. Bulk for bulk Keystone is much lighter All weights given are approximate only. 204 CRMC-003568 Johns-Manville Service to Railroads Where Used for Insulation or Sound Deadening Johns-Manville Keystone Hair Insu lator is recommended for the following uses but this is by no means a comprehen sive list as Keystone serves in almost every place where an efficient, durable material is desired for heat and cold insulation and sound deadening. Sound Deadening: Passenger sta tions, offices, residences, Y.M.C.A.'s, apart ment buildings, schools, hospitals, studios, hotels, dance halls, theatres, lodge rooms, dormitories, bowling alleys, etc. Insulation: Refrigerator cars, ice boxes, cold storage and refrigerating plants; all types of apartment houses and dwellings, factory or other roofs, poultry houses, garages, dairies, etc. Detail drawings on page 208 show some typical methods of installation. The Various Brands of Johns-Manville Keystone Hair Insulator Salamander--^Fireproof and damp- Neptune--Waterproof paper on one Asbestos paper on both ..sides. side and plain gray building paper on the .For. fire protection,as well as insulation other. For. use where protection against ,again.st heat and cold. dampness is desired. Also for sound deaden Packed in bales of 500 ing. Packed in bales of sq. fU, weighing 75 lbs. 500 sq. ft., weighing ----36" wide. 130 lbs.--36" wide. Double : Neptune -- Phoenix---Fireproof and damp-*proof Asbes tos paper on one side, and plain gray building paper on the other. Packed in bales of 500 sq. ft., weighing 100 lbs.--36" wide. Res. of J. C. Oliver, Sewickley, Pa. JohnsManville Keystone Hair Insulator makes every building more comfortable. Waterproof paper on both sides. For weather proofing against ex cessive dampness. Also for sound deadening. The best brand for this purpose. Packed in bales of 250 sq. ft., weighing 42% lbs.--36" Peerless--Wool felt wide. paper on one side and plain gray build Acme --Plain gray building paper ing paper on the other. Particularly on both sides. Can be used for all adapted for sound deadening where fur forms of general insulation and weather ring strips are not to be used. Packed in proofing. Packed in bales 18" or 36" bales of 500 sq. ft., weighing 85 lbs.--36" wide, containing 500 sq. ft. and weighing wide. 65 lbs. 205 CRMC-003569 Johns-Manville Service to Railroads Empire --The same as Acme Brand except that it has a thicker felting of hair and weighs more. Packed in bales of 500 sq. ft., weighing 80 lbs. Arctic--Arctic brand is especially adapted for cold-storage work. Covered both sides with heavy asphalt-saturated paper; water and vermin-proof. It is also used for insulation between walls in music rooms, such as phonograph rooms in de partment stores where transmission of sound is annoying. Packed in bales 3 ft. wide, containing 150 sq. ft., *4" thick, weighing 65 lbs. per bale, and %" thick, weighing 85 lbs. per bale. Excello--This is a rigid insulation with chipboard backing. It meets most satisfactorily the demand for panel insu lation in the erection of houses, garages, bungalows and other detached buildings. Furnished in sheets 3x8 feet and packed 21 pieces to the bundle, approximately 500 square feet. Packed for shipment a bundle will weigh from 165 to 170 lbs. Excello can also be furnished in panels 18" wide by 8 feet long, when so specially ordered. In many instances, the insulation will be used on the inside face of the studding. However, where studs are only 16" from inside to inside and it is desired to use the insulation between studs, the narrow 18" panel of Excello can be forced into place, bending it V on either side. This will not detract from the insulating value of the material and will not be considered objec tionable by contractors. Science Hail, a new building for Marshall College, Huntington, West Va., insulated with Johns-Manville Keystone Hair Insulator, Keystone makes every building warmer in winter, cooler in summer and quieter all the time. 206 CRMC-003570 Johns-Manville Service to Railroads Diagrammatic Drawings of Typical Wall Constructions for Johns-Manville Keystone Hair Insulator CRMC-003571 Johns-Manville Service to Railroads Details of Jokns'Manville Keystone Hair Insulator TYPES OF WALL AND PARTITION INSULATION TYPES OF FLOOR AND CEILING INSULATION SECTIONS THRO PAPT/TJOA/5 OyPSl/At 0/OCffS O/l HOILOH' T/IE KEYSTONEHAIR INSULATOR IN SUSPENDED CEILING KEYSTONE HAIR. INSULATOR UNDER ROOF KEYSTONE HAJ& INSULATOR UNDER FLOORS (rough andfinishedflooring foe-nailed ofedges) CRMC-003572 J ohns-Manville Industrial Flooring 209 CRMC-003573 Johns-Manville Service to Railroads Johns -Manville Industrial Flooring FLOORING that is a solid mono A lithic sheet of mineral without con struction joints or cracks; that can trucks, the hard knocks of massive castings or the comparatively light weight of foot traffic--and recommend a proper con be laid in just the right consistency and sistency and thickness of Johns-Manville thickness to meet the service conditions Industrial Flooring that will assure the under which it is to be used. A flooring that is resilient; slip-proof; easy under foot; dry and warm; fire re tardant; alkali and acid resistant. These are the features that make JohnsManville Industrial Flooring supreme in its field--that free it from the shortcom ings of other flooring which cannot be changed to accommodate the varying de mands Of different services. JohnS-Manville-Industrial Flooring is a combination of the best materials and the long experi ence of our engineers. greatest satisfaction. We know before any of the material leaves our factor}'what the floor must do and the recommendation of our engineer is rigidly followed by expert workmen whose skill is the result of constant application of our flooring in every part of the United States and Can ada. So, the flooring, from the first meas urement to the final finishing stroke on the top coat, is in the hands of conscientious experts--every precaution is taken and the responsibility for your satisfaction is con centrated in the Johns-Manville organiza- Its remarkable success is due: tion. 1. 'To the natural .durability of-the ma-. teriais of which it is made. Johns - Manville Industrial Flooring / 2. To it's "flexibility^ i which 'permits consists of a binder or asphalt cement fitting it exactly to service requirements, made up of a combination of natural as- an3_L ; ; phalts and a well graded mineral aggre- 3. To the fact that we Control every 'gate ranging in size from that passing a element in its man %" screen down to ufacture and appli that which passes a cation and can maintain a uniform ly high standard. There is no hit or miss about JohnsManville Industrial Flooring. Our en gineers carefully study your present 200 mesh screen. The finer aggre gate, or that passing an 80 mesh screen, is combined with the asphalt cement by heating and me chanical agitation at our factory for a or prospective ser period of several vice conditions -- hours. The mass whether the grind ing wear of heavy The extremely severe service conditions of the Canadian Pacific Railway Shop has proven the superiority of Johns-Manville Industrial Flooring. is then molded in to blocks of con- 210 CRMC-003574 Johns-Manville Service to Railroads venient size for shipment. These blocks are of 1*4" weighs only 18 lbs. to the square broken up on the work and reheated to a foot in place. temperature of 450 F., mixed with the coarser aggregate, using a pure asphaltic Easy and Economical to Repair flux to help break down the blocks in the This flooring is not only easily laid but kettle, giving proper consistency in the easily repaired if changes in the floor floor. surface are made necessary at any time or The resilient, softened and plastic mass where unusual hard service or accident re is transported to the work in oak buckets, quires an occasional patch. In fact it is the laid down hot in one and two courses, de only monolithic flooring which is so easy pending upon the re to repair. Just cut out quired thickness and then given a compara tively smooth finish by rubbing with wood floats. the damaged section, reheat the very mater ial that has been taken out, together with a small amount of flux Where Used-- How Laid which can be obtained from us, and then re lay it. The new spot, Johns- Manville In floated and rubbed dustrial Flooring can down to the proper be used for practically level, immediately be every condition in can comes one piece .with ning factories, railroad and has all characteris and machine: tics of the surrounding passenger and? freight floor, naturally so, be- stations, loading plat cause itis the same forms and docks, ware houses, freight .houses/ factories, roundhouses, cold storage, plants,: battery houses, chemi Johns-ManVille 'Industrial .Flooring is un: . equalled, for. .freight and. passenger station . platforms, A typical, installation- 'for the Southern Railroad, at Mobile, Ala. Of particular interest is the tabulation of. properties of various floorings shown on cal laboratories, C. A. buildings, page 212, which is the result of actual creameries/ packing houses, office build tests of all the materials mentioned. ings, school buildings, and institutions of every kind. It can be laid over any foundation which is firm and stable such as wood, brick, con crete or tile already in place, in any de sired thickness up to 3". The usual stand ard thickness is 1*4" which affords maxi mum service at a commensurate cost. Can be laid in sections of any size and its in stallation does not necessarily occasion any This tabulation affords a direct compar ison of the merits of Johns-Manville In~; dustrial Flooring with others. It is always dense, yet it has a certain amount of resiliency which prevents foot soreness and fatigue commonly caused by concrete and other non-yielding floor sur faces. Where employees of machine shops, factories and other operations are compel delay in the routine of operation of a plant. led to stand while at work this adds greatly It adds very little to the dead load of to their comfort and efficiency. Further the building as the standard thickness more, being dry and warm it is a protec- 211 CRMC-003575 Johns'Manville Service to Railroads tion against rheumatism and other ailments common to damp flooring conditions, \-iri ti -vr tiTt ^ * i Why Johns.'Manville Industrial Flooring IS Superior It is tough and elastic, it will withstand extremes of temperatures far better than any other monolithic floor and will not chip, crack, crumble ^ for factory and warehouse use even under the heaviest trucking conditions and on account of its noiseless character is a boon where traffic conditions and the consequent noise is objectionable. If your past experience has proved the old-fashioned types of flooring inadequate to your needs; if you are looking for a floor ^ ^ wh^ich ^will gi^ve points of. superior- - - ,, . ,T , .tv'-'- ' r_ : , , , . Thompson Chemical Laboratory,. Williams College, Ity are, brought out , Wiliiamstown; Mass., where johns-ManvilieAcid- by the Underwrit- proof Industrial Flooring >vas Chosen for its many -ers test, excerpt. s - ' excellent. qualities as well as its acid resistance. in .. the iy, e. ar in many . Snop IlOOrs where the traffic IS most severe and, not.hi.ng of which are shown on pages 213 and 214. but an exceptionally rugged floor could VV'here:light or accurate machinery is in last. One notable example is in the Cana- operation or merchandise is stored Johns- dian-Pacific Ry. Shops, Calgary, Alberta, Manville Industrial; Flooring is peculr... where 400,000 sq. feet--nearly ten acres-- iarly satisfactory because -it does not or- are in service, the largest floor area ever or hold dust. . It is unequalled , laid at one time with Industrial Flooring. PROPERTIES OF VARIOUS FLOORINGS Industrial Common Paving Flooring Brick wrick 1. Acid Resistance.................... ----- -------100 80 100 . 2. Alkali Resistance................. ...100' 95 100 .3. Durability ............................. 75 60 100 4. Elasticity ............................... ................. 60 0 5 5. Fire Resistance .................. ........ 75 100 100 6. Non-Abrasion .................... ................. 95 0 30 7. Non-Slip ............... 100 100 30 8. Quietness ............................... ............... 75 10 5 9. Resilience ............................... ............... 90 0 4 10. Sanitary ............................. ............... 70 6 50 11. Thermal Insulation............. ............... 60 10 0 12. Waterproof ........................... ................ 100 0 10 ConCrete 50 70 90 1 100 10 70 5 1 40 5 60 Maple 30 90 50 90 0 95 50 50 90 35 90 25 Average ............................... .....................83.3 38.4 44.5 41.8 57.9 Oak . 33 90 50 90 0 95 50 50 90 35 90 25 Pine 30 90 ` 40 90 0 88 60 60 90 0 90 25 58.2 53.6 Note the very high average for Johns-Manville Industrial Flooring 212 CRMC-003576 Johns-Manville Service to Railroads We shall be glad to make a small in stallation knowing that the results will demonstrate conclusively the many ad vantages of Johns - Manville Industrial Flooring. Why not try this plan in some part of your plant where other floorings have not given proper service? It will af ford an opportunity to make a personal test of Industrial Flooring where you can convince yourself by actual use. Let us know your conditions. We will recom mend the proper consistency and put in a test section. You will then be able to de termine that it is BEST BY TEST. Our Engineering Department will be glad to confer with you on any of your flooring problems. Johns-Manville Industrial Flooring as Fire Retardant odern M building practice de mands that as many Properties" the re port of Underwrit ers' Laboratories, Inc., says of Johns- of the materials as Manville Industrial possible be fire-re Flooring:--- sisting to the great est possible degree. The following facts "The top flooring isn o t readily inflam mable and does not. on Johns - Manville Industrial' Flooring, will answer your rn.o s t .searching questions as to its. ability to retard fire. : A. few years ago the National Board Showing how J.ohns-Mativille Industrial Flooring" is laid. . The ;care used;.in selecting and. mixing the proper- materials, for each condition and the skill of these workmen in; application assures uniform re- ' ' - suits and satisfactory service. carry or communicate, fire to any material-ex tent It disintegrates, slowly under- heat, af fords.. very v consider able . heat insulation to-> the floor.structure.,and-., the progressive disin tegration does not ma of Fire Underwriters completed exhaust ive tests to determine the fire-retardant qualities of Johns - Manville Industrial Flooring. The following excerpts from their re terially reduce the insulation afforded. "By comparing a sample of the `Industrial' top flooring with a sample of the maple flooring, it will be seen that the maple flooring was readily inflammable and carried and communicated fire to a material degree, giving off flame in consid port (dated August 21, 1917) substantiate erable volume and more or less smoke. By re our claims for our Flooring as a fire-re tardant and the excerpts are vitally impor tant to every one interested in flooring for industrial and mercantile plants, pub ferring to the logs cf tests it will be seen that flames developed on the maple sample in 1 min ute and 45 seconds after which it burned readily and spread rapidly, reaching the unexposed end of the sample in 20 minutes. lic and private institutions, shops, brew "In the case of the `Industrial' sample, flame eries, packing houses, laundries, railway buildings and all floors where the service is particularly severe. Under the heading of "Fire-Resisting developed in 5 minutes and 50 seconds and spread slowly, giving off short, intermittent flames. At the end of the test (1 hour and 10 minutes), it had only reached to a point 6 feet from the ex posed end of the sample. At the end of the test, 213 CRMC-003577 Johns-Manville Service to Railroads after the exposing flames had been extinguished and the gases of combustion given off from the wood at the edges of the sample had been quenched with water, the surface of the sample ceased to burn." In addition to their findings concerning the fire-resisting qualities of Industrial Flooring the Underwriters' Laboratories, Inc., also included in their report much interesting data on its design, construc tion, practicability, durability, etc. Quo tations follow:-- Design and Construction "The design and construction of the top floor ing are suitable for the purposes intended. The materials are suitable for the purpose, forming a homogeneous mass which can be readily in stalled under ordinary service conditions." Practicability "It is practical to prepare the materials as furnished to the job and to apply them in the manner advocated. The flooring can be easily re- paired or maintained if repairs and maintenance are required." Durability "All floorings examined in the field were sub knowledge of the materials used indicates that, if ject to hard usage and in no case was there any anything the top flooring should have a preserva- apparent deterioration from the effects of wear. tive effect. "In .none of the. installations examined was "Although the; floorings were carefully exam there any evidence of deterioratioii- in the top ined for cracks which would ordinarily indicate flooring due to expansion, contraction or settle failure of the surfacing to conform to the expan- ment of the building. In only one of the.instah . sion and,contraction of the main flooring in which lations examined- was the top flooring exposed to. it rests,: no cracks were discovered, indicating that the elements, but this 'installation appeared to be the surfacing is not open to criticism.in this par in good condition. V;,' ticular. In only one of the installations examined "While the investigation did not give positive was the flooring exposed to the elements, but no evidence to the effect that the top floor has no criticism developed in the case of this installa deteriorating influence bn the floor structure, a tion." "This flooring material, by offering a relatively high resistance to slipping, should reduce the accident hazard due to this cause. . "The examination of the material indicated a structure presenting a suitable anti-slip surface both when new and worn. "The friction tests brought out results compar ing favorably with results of test on anti-slip sur faces which have proven to be effective in reduc ing accidents due to slipping. "Examination made in the field showed no marked difference in the resistance to slipping after being subject to actual service conditions." 214 CRMC-003578 Johns-Manville Service to Railroads Specifications for Johns-Manville Standard Industrial Flooring Over Wood Sub-Base 1 Over the wood sub-base lay a heavy rosin-sized building paper lapping same one-half its width. 2 The Johns-Manville Standard Industrial Floor ing Blocks shall be delivered on the ground, plainly marked with the brand and broken up before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral aggregate shall then be added and thoroughly mixed into the mass by use of iron stirring rods and the temperature of the mixture brought to 450 F. The material shall be frequently stirred to prevent burning and then removed from the kettles in oak buckets or all iron wheelbarrows and taken to the work as required. coarse sand, gravel, trap rock or any crushed stone of sufficient hardness. 4 This flooring shall be laid in one course to a thickness of 1", spread with wood floats and suffi cient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint al ready on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats. 5 The top surface of the floor shall be given a sand finish in the following manner: The top surface while hot shall be sprinkled with a fine dry sharp sand, which shall be thoroughly rubbed into the surface of the flooring and the surplus sand allowed to remain on the floor until the same is put in use. 6 The mineral, aggregate shall be thoroughly, dry .: In case of a cement finish the top surface shallbefore being introduced into-the, mix and shall: be sprinkled and. rubbed with sharp sand, which be a clean, well graded material of.:a .size, to\meet ;. shall then be swept off while the material is still, the., particular.'; service conditions encountered.: , warm. . The surface shall; then .be dusted with The . mineral aggregate, is to consist -of a sharp, r Portland .Cement, and .same thoroughly rubbed in;- --OR*-- . This .flooring shall ,be laid- in one course to a already on the floor and allow it to remain until thickness of spread with wooden: floats and ..the, same is thoroughly heated. The surplus ma-. sufficient pressure applied to eliminate all 'voids . terial shall then be cut off and the . joints made and blowholes.; When the joints are made, place ; compact arid tight by rubbing with wood floats, the hot mixture over the cold edge of the joint --OR*-- This flooring shall be laid in two courses to a total thickness of 154". It shall be spread with wood floats in such a manner as to avoid; bring ing the joints in the two courses directly over each other, and these joints shall be lapped at least 12" and sufficient pressure applied to elim inate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats. Preparation of Floor Surface (To be incorporated in Carpenter s Specifications) The wooden sub-base shall be securely nailed and free from loose ends or sharp projections and pitched, if necessary, to proper grade for drainage. It shall be of sufficient strength to support the loads contemplated, *Where either of these alternates is used it should be substituted for paragraph 4 in the complete specifi cation above and paragraphs 1, 2, 3, 5 and 6 included. 215 CRMC-003579 Johns-Manville Service to Railroads Specifications for Johns-Manville Standard Industrial Flooring Over Concrete i3 The Johns-Manville Standard Industrial Floor This flooring shall be laid in one course to a ing Blocks shall be delivered on the ground, thickness of 1", spread with wood floats and suffi plainly marked with the brand and broken up cient pressure applied to eliminate all voids and before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral aggregate shall then be added and thoroughly mixed into the mass by use of iron stirring rods blowholes. When the joints are made, place the hot mixture over the cold edge of the joint al ready on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats. and the temperature of the mixture brought to 4 450^ F. The material shall be frequently stirred The top surface of the floor shall be given a to prevent burning and then removed from the sand finish in the following manner: The top kettles in oak buckets or all iron wheelbarrows surface while hot shall be sprinkled with a fine and taken to the work as required. dry sharp sand, which shall be thoroughly rubbed into the surface of the flooring and the surplus 2 sand allowed to remain on the floor until the The mineral aggregate shall be thoroughly dry same is put in use. before being introduced into the mix and shall- 5 be a clean, well graded material of a size to meet In case of a cement finish the top surface shall the particular service, conditions encountered, be sprinkled and rubbed with fine sharp sand, The mineral aggregate, is to consist of' a. sharp, which shall then be.swept off while the material is coarse:-sand, gravel, trap rock or any crushed, still warm. The.surfa.ee shall then be dusted with stone of..sufficient, hardness. . . . Portland Cement and same thoroughly .rubbed in. --OR*-- ' This "flooring, shall;be laid in one course ;to .a thickness of spread, with wooden .floats and sufficient pressure; applied to eliminate .all voids and blowholes. ; .When, the joints'are made,' place the: hot mixture over 'the'cold' edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight-.by -rubbing, with wood floats: This .flooring shall be laid in two courses to a , totalthickness of /lpj".. It shall'be spread with wood floats in such a manner as to avoid bring ing the joints yin .the two courses directly over' each other, and these joints shall be lapped at least 12" and'sufficient pressure applied fo elim inate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The' surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats. Preparation of Floor Surface (To be incorporated in NqsotCs Specifications') After the concrete base has been placed and pitched, if necessary, to the proper grade for drainage, it shall be given a screeded and floated surface free from all sharp projections or offsets of any character except those shown on the plans, The concrete shall then be allowed to set and dry out. *Where either of these alternates is used it should be sustituted for paragraph 3 in the complete specifi cation above and paiagrapns 1. 2. 4 and 5 included. 216 CRMC-003580 Johns-Manville Service to Railroads Specifications for Johns-Manville Acid-Proof Industrial Flooring Over Wood Sub-Base 1 Over the wood sub-base lay a heavy rosin sized building paper lapping same half of its width. 2 The Johns - Manville Acid - Proof Industrial Flooring Blocks shall be delivered on the ground, plainly marked with the brand and broken up before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral aggre gate shall then be added and thoroughly mixed into the mass by use of iron stirring rods and the temperature of the mixture brought to 450 F. The material shall be frequently stirred to prevent burning and then removed from the ket tles in oak buckets or all iron wheelbarrows and taken to the work as required. 3 The mineral aggregate shall be thoroughly dry before being introduced into the. mix and . shall be a- clean,, well, graded material of a size to meet the ' particular ' service conditions' encountered. The mineral aggregate is to consist of fine silica sand, silica pebbles, certain trap rocks or any crushed stone or granite of sufficient hardness and which is immune to the action of all commer cial acids, except hydrofluoric. 4 This flooring shall be laid in one course to a thickness of 1", spread with wood floats and suf ficient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint al ready on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats. 5 The top surface of the floor shall be given a sand finish in the following manner: The top surface while hot shall be sprinkled with a fine dry sharp sand, which shall be thoroughly rubbed into the surface, of the flooring and the..surplus sand allowed to remain on' the floor ..until" the same is put in. use. . __OR*-- This flooring shall be laid in -one: course to a : thickness of: 1 spread with wooden floats and sufficient pressure, applied to eliminate'Sail voids . and'blOwholes. When the joints are made,' place the hot mixture over the cold edge of the-joint al ready on the flobr;and allowTt-to remain until, the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood, floats. _OR*^ This flooring shall be laid in two courses to a total thickness of shall be spread with wood floats- in such a manner as to avoid' bring- - ing the joints in the two courses directly over each other, and these joints shall be'lapped at least 12" and sufficient pressure applied to elimi- nate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats, Preparation of Floor Surface (To be incorporated ui Carpenter's Specifications) The wooden sub-base shall be securely nailed and free from loose ends or sharp projections and pitched, if necessary, to proper grade for drainage and shall be of sufficient strength to support the loads contemplated, "Where either of these alternates is used it should be substituted for paragraph 4 in the complete specifi cation above and paragraphs 1. 2, 3 and S included. 217 CRMC-003581 Johns -Manville Service to Railroads Specifications for Johns-Manville Acid-Proof Industrial Flooring Over Concrete 1 The Johns - Manville Acid - Proof Industrial Flooring Blocks shall be delivered on the ground, plainly marked with the brand and broken up before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral ag gregate shall then be added and thoroughly mixed into the mass by use of iron stirring rods and the temperature of the mixture brought to 450 F. The material shall be frequently stirred to prevent burning and then removed from the kettles in oak buckets or all iron wheelbarrows and taken to the work as required. 2 The mineral aggregate shall be thoroughly dry before being introduced into the mix and shall be a clean, well graded material of a size to meet the particular service conditions encountered, The mineral aggregate is to consist of fine silica sand; silica pebbles, certain trap rocks or any crushed stone or granite of sufficient hardness and which is immune to the action of all commer cial acids, except hydrofluoric. 3 This flooring shall be laid in one course to a thickness of 1", spread with wood floats and suf ficient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats. 4 The top surface of the floor shall be given a sand finish in the following manner; The top surface while hot shall be sprinkled with a fine dry sharp sand, which shall be thoroughly rubbed into the surface of the flooring and the surplus sand allowed to remain on the floor until the same is put in use. --or*-- This flooring shall be laid in one course .to a thickness of l%", spread' with wooden floats and .sufficient pressure-applied to eliminate all voids and blowholes^ When the joints are made, plate the' hot- mixtures, over'the cold edge of the joint already on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats* --OR*-- This flooring shall be laid in two courses to a totaFthickness of IJ2". It shall be spread with wood floats in such a manner as to avoid bringingUhe joints in the two courses directly over each other, and these joints shall be lapped at least 12" and sufficient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats, Preparation of Floor Surface (To be incorporated in il/ason's Speci/icotionsJ After the concrete base has been placed and pitched, if necessary, to the proper grade for drainage, it shall be given a screeded and floated surface free from all sharp projections or offsets of any character except those shown on the plans. The concrete shall then be allowed to set and dry out. *Where either of these alternates is used it should be substituted for paragraph 3 in the complete specifi cation above and paragraphs I. 2 and 4 included. 218 CRMC-003582 J ohns-Manville Waterproofing and 219 CRJVfC-003583 Johns-Manville Service to Railroads Waterproofing--What It Is ATERPROOFING is a broad crete recommends abandoning this Wterm often misapplied and misun method. derstood. In reality waterproof ing should only be thought of in the pres The Membrane Method- ence of seepage or where there is actual water pressure arising from such seepage and pressure conditions. Every other case of "waterproofing" properly comes under the head of Damp-proofing. For these conditions Johns-Manville can sup ply you the proper materials for either prevention or correction. Why It Succeeds This method provides for the applica tion of a protective bituminous skin or membrane over the surface to be water proofed as shown in details on page 224. The membranous covering of waterproof ing asphalt, reinforced with suitable fab ric or felt or both, is strong and flexible Damp-Proofing and has the necessary characteristics to resist water pressure and enough "give" Damp-proofing is protection against to bridge over hair cracks in the concrete moisture where no actual water pressure due to temperature changes. is encountered. It is simply the preven The membrane is built up in as many tion of dampness penetrating walls or plies of reinforcing' material as is neces floors. :1 sary to meet the conditions, and these plies are bonded together and to the concrete Two Methods of Waterproofing, Integral and Membrane with asphalt cement. It is conceded that a carefully com bined asphaltic compound is the most ef It is an accepted-fact among engineers fective and durable waterproofing sub and arehitects.that there are but two meth- stance in existence. As the base of all , ods of waterproofing, but it has been provx : Johns-Manville Waterproofing materials en that ONLY ONE of them is capable of we have chosen Gilsonite which is the pur giving permanent, positive results. . est form of asphalt known. However, in spite of its great purity, Gilsonite requires The Integral Method-- Why It Fails special preparation before it can be suc cessfully used commercially. By our ex clusive process of refining and combining This method provides for the incorpora... tion of a powder, paste or liquid into the concrete during- its construction. It is mixed with the cement, becomes part of the' mass and is supposed to add to the density of the concrete to such an extent other natural asphalts with Gilsonite, it is rendered remarkably ductile and adhesive, characteristics which adapt it more per fectly than any other material to with stand the peculiar and exacting condi tions of service to which it is subjected. as to prevent the seepage of water. It fails when hair cracks or larger open ings develop in the concrete, due entirely Johns-Manville Membrane Waterproofing to expansion and contraction or unequal In selecting a material for waterproofing settlement in the structure. The Joint purposes, the first consideration is dura Committee on the Waterproofing of Con bility. Waterproofing that is not perma- 220 CRMC-003584 Johns"Manville Service to Railroads nent is a mere makeshift and actually worse than none at all because of the ex pense, inconvenience and loss of time in connection with correcting it, to say noth ing of the damage generally caused by its failure. Johns-Manville Membrane Waterproof ing is the result of years of experience in the successful waterproofing of every con ceivable type of construction. It has been proven by actual experience to be the most economical, not in the first, but in the last cost, and the most satisfactory because IT IS WATERPROOF--NOT APPROXI MATELY BUT ABSOLUTELY WATERPROOF. Material used in Johns-Manville Waterproofing Johns - Manville hot. One ton of this Concrete Primer This is the first coat ing applied to the con crete, brick or stone material should cover 3000 square feet of sur face Vs of an inch thick. Johns-Manville surfaces which are to Asbestos be waterproofed. It penetrates the : surface Waterproofing Felt to such an extent as to, Used as a reinforce form an anchorage for ment and to give body the subsequent water Showing typical application of. Johns?Man- and substantiality to proofing. It also acts as a cleanser for the ville Waterproofing, Materials to foundation walls of Buffalo Wat.er .Works, Buffalo, N. Y. the membrane; ce mented together and surface, preparing it ' : V bonded to the concrete for the asphaltic coatings to follow'. The: by t--he- wa. .t.e.Tripr roofing cement. It is made covering capacity of. this material should , of pure asbestos (rock fibre), thoroughly run about 100 square feet to the gallon on impregnated with pure asphalt. This is comparatively, smooth surfaces': v the only all-mineral felt made, therefore, : Johns-Manville the only material of its kind that is proof ; against water, cold acid, mold and decay, Asphalt Waterproofing Cement r ca for all time. Virtualiy a pliable bituminized otone sheet. Furnished in two This is applied while hot over the Prim weights, 14 lb., felt in 3 square rolls and er and is used to cement the various fab 35 lb. felt in 2 square rolls. rics together into one composite sheet. Owing to great care exercised during the process of manufacture, this bituminous material is absolutely uniform in charac Johns-Manville Asphalt Saturated Fabric ter. It is 99.5 per cent pure and contains Used not only as a reinforcement for no matter that will disintegrate or decay. the membrane but to give added tensile Proof against the action of cold acid, al strength. It is an especially strong cotton kali, brine and water; very slightly affect fabric or duck used in connection with ed by a wide range of temperatures be Asbestos Waterproofing Felt in as many tween melting and brittle points. To ap plies as are required to meet the condi ply this Waterproofing Cement it is tions. Being a loosely woven material, the heated to 450 deg. F. and mopped on while waterproofing cement, which is mopped 221 CRMC-003585 Johns-Manville Service to Railroads on hot, thoroughly impregnated, cements if desired with a melting point of 150 deg. and bonds together the several plies of the F. In lining wooden tanks it is sometimes reinforcement. used to coat the tongues and grooves of the boards when the tank is being built, Johns-Manville Self-Healing Waterproofing Cement the boards being drawn tightly together and held in place permanently by the use of wooden dowels. After the tank is This is an asphaltic compound -which carries a very low congealing point and a melting point of 125 deg. F., although we can furnish it with a melting point of 90 deg. F., when a softer material is desired. The use of this product is naturally limit erected the inside is primed and given from two to four coats of the Pickling Tank Cement. It is immune to all the cold commercial acids, including hydro fluoric. It is shipped in iron drums weigh ing approximately 400 pounds. ed for waterproofing purposes on account of its tendency to move readily under Johns-Manville Expansion comparatively high temperatures and also Joint Filler its extremely viscous nature. For brine An asphaltic compound of great tenac decks in packing-house hog-coolers and ity and elasticity. Used for filling expan for waterproofing work between wooden sion joints. It is capable of taking care of floors, this material is ideal. We have also certain movement in structures, paying found that on account of its adhesiveness and road work due to expansion and con at low temperatures it makes an excellent traction. It is melted and poured into : expansion-joint filler arid we are using it . place. Immune to the action of street largely for that purpose. It is shipped in . acids. Shipped in iron drums of approxi .wooden barrels weighing approximately. mately 400 pounds each. .500 pounds and; half barrels weighing ap proximately 250 pounds. .. Johns-Manville Bituminous Putty Johns-Manville Pickling Tank Cement This is ail asphaltic compound; evolved . principally for. use in lining the inside of wood of concrete tanks where an acidproof coating is a necessity. It is mopped on the surface in a heated condition and carries a melting point of 200 deg. F., al though a. softer material can be furnished This material is composed of an asphal tic compound and asbestos fibre, used as a filler to prevent the infiltration of water in recesses where a permanent seal is hard to maintain with the waterproof membrane. It forms an elastic, bond but little affected by temperature . change and vibration. Largely used in connection with certain types of bridge waterproofing where the waterproof membrane is sealed to the sides of the girders. Johns 'Manville Damp -Proofing In the large majority of cases the appli cation of cold surface coatings will effec tively damp-proof any structure. There are, however, special cases of damp-proof ing which require the membrane method of waterproofing. We firmly believe, and successful installations prove, that JohnsManville Damp-proofing is the most effi cient system to keep out dampness and to prevent discoloration due to the absorp tion of moisture. 222 CRMC-003586 Johns-Manville Service to Railroads Johns-Manville Johns-Manville Aquadam Liquid Waterproof Coating This is applied cold over brick, stone or HIS is used in connection with Johns- tile and concrete surfaces, where it is re- TManville Concrete Primer, and is ap- quired to damp-proof the walls and proplied cold in one or two coats, for vide a plaster finish over the damp-proof- damp-proofing only. It is used for wall ing. In tile partitions it prevents dampness work or for other surfaces not liable to from driving the saltpeter out of the tile, injury from abrasion and where there is through the plaster and discoloring the no hydrostatic pressure. It will withstand decorations. seepage of surface water and prevent the It is applied in one or two coats, de discoloration or staining of the outside pending upon the porosity of the surface, face of concrete walls. It has a covering It has a covering capacity of about 80 capacity over smooth surfaces of about square feet per gallon. 2-00 square feet to the gallon when used -- over the Primer. All Johns-Manville Waterproofing ma- _ ... ^ 0 n i terials are sold on an f.o.b. basis, for appli- Johns-Manville Cut Stone Backing cation by the user or local contractor. This is used for coating the sides and back of .cut stone to prevent discoloration ; and dampness of inside or anterior walls, It should cover approximately 6.0 square feet: per gallon over rough surfaces. The felts are furnished in rolls, ready for use and the various asphaltic cements, putty and coatings are packed in containers most convenient for shipping and handling on the job. Applying Johns-Manville Waterproofing on side walls. See detail drawings on page 224. 223 CRMC-003587 Johns-Manville Service to Railroads Details of application'of 3-Ply Built-Up Waterproofing Membrane. Details of application of 2-Ply Built-Up Saturated Fabric Waterproofing Membrane. 224 CStMC-003588 Johns-Manville System of Acoustical Correction 225 CRMC-003589 Johns -Manville Service to Railroads Johns -Manville System of Acoustical Correction OR the elimination of unnecessary Fand disturbing sounds, reverberation, echoes and poor acoustics in Railroad Passenger Stations, Offices, Banks, Thea tres, Schools, Colleges, Auditoriums, Clubs and Hotels. The Acoustical De partment of Johns-Manville Inc. is main tained for the purpose of conferring with architects and owners in the design and construction of new buildings to in sure good acoustical conditions as well as to correct poor acoustics in structures already built. Through its System of Acoustical Correction the Johns - Man ville Company is prepared to produce good hearing qualities in auditoriums of churches, theatres, court-rooms and. other public buildings; also to reduce to the mini Waiting Room, Southern Pacific Railroad, Oakland, California, Jarvis Hunt, Chicago, 111., Architect; The annoyance of noises common to railroad stations has been eliminated by the installation of Johns-Man- ville Acoustical treatment on ceilings. mum the fatigue and. loss of efficiency due to confusion and noise in. offices, . and these factors must be carefully stud- banks, hospitals and rooms of similar; led in every case. The nature of the treat character, resulting from the unavoidable ment, its amount and location, is a matter concentration of, employees and' noisy, md- for expert determination. The problems chahical office appliances... ` involved are highly technical and for their In broad terms., good acoustics requires' satisfactory solution the trained know that there shall be no confusion or blur- ledge of specialists is indispensable. ring 7 of speech; or music due to over- Through the Johns-Manville Company, lapping or interference of tones and syl the services of competent acoustical engi lables and that everything shall be done neers are available to architects and others to bring about that clarity of tone which; who have acoustical difficulties to be over is consistent with the maintenance of suf come. The methods used are based on the ficient loudness and proper balance. The scientific researches of the late Professor acoustical conditions of any room are af W. C. Sabine of Harvard University and fected partly by size and shape, and partly the Johns-Manville Company has devel by the character of interior surfaces and oped special materials and methods of ap furnishings, as well as by the distribution plication for producing the necessary cor and size of the audience or occupants. rection. A certain amount of absorption is neces The Johns - Manville engineering ex sary in every auditorium. In some cases perts are prepared to examine plans and furniture and the clothing of persons pro specifications at any time, without fee, vide all that is needed in this respect, but and to recommend suitable treatment more often artificial treatment is required where it may be necessary. 226 CRMC-003590 J ohns-Manville Electrical Materials 227 CRMC-003591 .?'B Johns^-Manville Service to Railroads Johns-Manville Ebony Asbestos Wood johns-Manville Ebony Asbestos Wood has been examined and approved by the Underwriters' Laboratories, Inc., under the direction of the National Board of Fire Underwriters. OHNS-MANVILLE Ebony Asbestos factor when the loss due to handling more JWood is recommended for use as an in sulating base for switchboards, panel fragile materials is considered, and its lightness is in its favor both on the basis boards, bus bar barriers, switch bases, inof mechanical strength and the saving of sulators for collector rails on ore bridges freight charges. and all kinds of cranes, charging and For years the chemical industry has been drawing machines in coke plants, third looking for an ideal material for labora rails on top of coke ovens, etc. It is of tory table tops, sink tops, lining hoods fered in the form of composition sheets over hot tables, and cabinet hood linings. made up of asbestos fibre and binding The perfect material would be one cements and which would be im densely impregnat pervious to chemi ed under heat and cals, acids and acid pressure into; 'a fumes, one that compound 6 f very would.not break high die 1 e c t r i c glass containers on strength. / :: account of tempera /This material pos-r. ture : change when -. sesses the least pos they are put down sible -surface leak while hot. ; age, feeing .affected. The ideal mater / neither by oil -nor, atmospheric . mois- , ;i, .. , ture, nor Win- It- rot . nr rilof pxTpn .when exposed to the ac- Sections of switchboards at United Electric Light & Power Co., Hell Gate/ New York City, one of the most,, modern-power stations in the world. JohnsManville Ebony Asbestos Wood was chosen for the huge switchboards and; many other uses because of its superior dielectric strength, ability to withstand vV1ibUrIaOtViioVnJll-aCknllXdX ashuovcvkfi faiHnUd flirPeCeUdWoMmii furoumiu m414eC1ta01lJlAicI* vWeiinll?s.. ...... ial has been discov ered in Johns-Man ville Ebony Asbes tos Wood. Johns - Manville tion of water, gas, oil, chemicals or ordi- Ebony Asbestos Wood is taking the place nary acids. Although comparatively light of slate, porcelain and Alberene stone in in weight, Ebony Asbestos Wood has hundreds of plants for hundreds of dif- great physical strength due to its fibrous ferent uses. structure, hence is free from ruptures due On the next page there are shown some to rapid temperature changes. It will with- typical uses of Johns-Manville Ebony As- stand heat up to a temperature of 500 de- bestos Wood in industrial plants. There grees F. and is not likely to warp, shrink, are uses in your plant--find them--and crack or buckle under extreme service con- increase your production by reducing ditions. This strength is an important breakdowns to the minimum. 228 CRMC-003592 Johns-Manville Service to Railroads Some Typical Uses for Ebony Asbestos Wood Disconnecting switch bases for lightning arresters Primary fuse boxes Washers to separate bus rings Terminal blocks, motor and generator Back board controllers Charging rheostats Theatre pockets Theatre expansion plugs Theatre boxes and dus ters Button switch boxes Wattmeter bases Ground, petticoat and line insulators Lightning arrester boxes Panels for switchboards Switch barriers Faces for rheostats of all kinds Electric elevator controls Shunt bases Fuse blocks Exciter panels Cabinets for distant con trol of oil switches Converter panels Barriers to separate units Wire cleats Divider cleats Bus bar supports Resistance boxes Distributing boards Linings of cabinets Mercury arc rectifier pan els Solenoid switches Back connected switches Cabinets Small wire holders for in strument connections Dinkey controllers INSULATION RESISTANCE IN MEGOHMS PER SQUARE INCH OF SURFACE, AT 18; C. Thickness %".................. Va"............. v%".................. V.................. w.................. ___ ____ ____ ____ Resistance As Received, Megohms 475,000 1,700,000 2,500,000 3,000,000 3,200,000 After 96 Hours Immersion, Megohms 50,000 1,000,000 1,500,000 1,900,000 2,500,000 Thickness 3/4".................. ......... 1" .................. ......... U4".................. ......... ilA".................. ......... 2" .................... ......... Resistance As Received, Megohms 3,500,000 4,000,000 5.000,000 6,000,000 7,500,000 After 96 Hours Immersion. Megohms 3,000.000 Above 3,000.000 Above 3,000.000 Above 3,000.000 Above 3,000.000 COMPARATIVE TABLE OF PHYSICAL PROPERTIES OF SWITCHBOARD MATERIALS B-V Marble Slate Soapstone Johns-Manville Ebony Asbestos Wood Weight per cubic foot............................................... Dielectric strength, one inch in thickness.... ... 65,000 V Insulation resistance: per one. inch cube...... ... 170,000 meg. Crushing strength per square, inch'........... . 13,000 lb. . Transverse, modulus of rupture in'lbs. per sq. in.. 8901b., 1801b. 8,000 V 25 meg. 10,000 1b. ,6,2001b.. 175 1b. 121 lb 25,000 V, 76,000 V 250 meg. 4,000,000 meg. '. 8,000 lb. . 15,0001b. 1,300 lb. . 3,500 lb. NOTE:--The figures in1 this table are the values obtained by actual test, and care should be taken not to use .the strength' ejven : in construction, without a suitable factor cfsafety. The insulation resistance and puncturing voltage of slate, marble and soaostone ' are only approximate; since individual-specimens of the same kin d vary 500 % among themselves'; - . . 'Th preceding; tabie has beeri-computed'on the'basis of tests made in the dry state and the materials are' considered to have absorbed no moisture..: The results, would be different if figured on tfiie basis of absorption,; with the exception' of -soapstone\and Johns-Manville; .Ebony Asbestos Wood, which are practically unaffected!' after immersion in water for 'any length of: time. . The result on marble and slate would be considerably re-, duced after immersion in water. PUNCTURING VOLTAGE Thickness Puncturing . Voltage Average Thickness Puncturing Voltage Average Thickness Puncturing Voltage 'Average Thickness Voltage: Average v%........ ... 12.900' V':....... 37.000 'VA"................ . . . 54,000 IV........ .. 80,500' Va"........ . S/8 ........ . . . 43,000 1" ................ . . . 66,000 1 Vi ............... . 85,000 ... 30,500 2" ................ . . . 96,000 WEIGHTS AND LIST PRICES This material is supplied in standard size sheets 36" x 48", 42" x 48" and 42" x 96" in the following thicknesses: Weight per Thickness Square Foot y8--............ ...................... 1,50 lbs______ List Price per Square Foot $0 90 *v*............. v............. .......................2.75 .......................... 1.20 " ... ....................... 1.30 ......................3.50 "... ......................... 1.45 W *A" Vs ............. ...................... 4.25 ............. ...................... 5.43 ............. .......................6.88 " " ... " ... .......................... 1.60 ......................... 1.90 .......................... 2.35 Prices on thicknesses above 2" on application. Thickness Weight per Square Foot List Price per Square Foot 74" 9 00 " ............................ $2.50 1" 10 35 " Wa" l'A" Wa" 2" ............. ................... 12.85 ............. ................... 15.00 ............. 17 80 ............. ....................20.65 ". ". * ". ............................... ............................... ............................... 3.10 3.65 6.20 * Supplied only in sheets 36" x 48". 229 CRMC-003593 Johns-Manville Service to Railroads Johns'Manville Transite Asbestos Wood Examined and approved by the Underwriters' Laboratories Inc., under the direction of the National Board of Fire Underwriters, . Oil switch .compartments and transformer protective cover of Transite Asbestos Wood. Insialled at Station F, Pacific Gas and Electric Co., San Francisco, Calif. OHNS-MANVILLE Transite Asbestos Transite Asbestos Wood can be fasten- JWood is recommended for general elec- ,ed with nails or screws, takes any kind of trical construction.use, and is most satr. a wood finish, yet withstands successfully isfactory where ;_'.fireprdo, heat-resisting,, .the most severe fire tests and sudden material is. required and. great dielectric , changes of temperature. '' Will not warp; strength, is not necessary. It has, proven.;. or become distorted! or. weakened in ser-- to be most durable for bus bar barriers, vice; in fact, it actually becomes tougher transformer doors, fireproof lining or con- with age. tainers and other, forms of construction . Supplied in sheets .36" x 48", 42" x 48" . throughout the plant where long-contin- and 42" x 9.6" in various thicknesses from ued, positively fireproof service is essen- to 2". tial. Some of the Electrical uses of Transite Asbestos Wood Bases and floors about '. switchboards Washers to separate bus rings Troughs about wires Lightning arrester boxes Switch barriers Shunt bases. . Resistance boxes Potential transformer Charging rheostats boxes - EquaiizeJ. bases Frames for small boards p e b x s Protection from magnetic blow-outs on railway Panel board hners cars Wattmeter bases Barriers to separate units Wire cleats, large and small Separation plates for street car controllers Electric elevator controls For uses and application of Transite Asbestos Wood for building- purposes see page 1SS. WEIGHTS AND LIST PRICES OF FLAT TRANSITE ASBESTOS WOOD Thickness in inches 1 Weight per sq. ft. 1.7 lbs. 2.1 " 2.8 - 3.4 " Price per sq. ft- 0.15 0.225 .30 .38 Thickness in inches J 1 1 Weight per sq. ft. 4.0 lbs. 5.3 " 7.6 " 10.1 " Price per sq. ft. 0.45 .60 .90 1.20 Thickness in inches 1! 11 l? 2 Weight per sq. ft. 13.0 lbs. 15.7 " 18.S " 21.0 " Price per sq, ft. 1.50 1.80 2.10 2.40 230 CRMC-003594 Johns-Manville Service to Railroads Orangeburg Fibre Conduit Manufactured by THE FIBRE CONDUIT CO., Orangeburg, N. Y. JOHNS-MANVILLE INC., NEW YORK CITY SOLE SELLING AGENT RANGEBURG fibre conduit is a Standard Specifications--General Obshuearcgrdti,oFntio.burIegnhCmocaonnndudufuiat,ict,tBuceryinnldignsdOrairncadanlgFeinittinwgist1h. It shall be thoroughly insulating compound. impregnated wet wood pulp fibre is formed on a 2. The walls shall be compact and mandrel to the desired length and incapable of separation into layers thickness of wall. The individual when heated to 212= Fahr. fibres become felted into and form a 3. The material shall not be af solid, homogeneous wall. Taken off fected by acids which may be present the mandrel, the wet pulp structure is in the ground and shall itself be free from subjected to a drying process, after which any substances which might corrode the it is placed in a vat of bituminous impreg sheath of leaded cable. nating liquid compound. There are suffi 4. The bore shall be straight, the cient creosote salts in the compound to cross-section shall not vary at any point kill any vegetable matter or bacteria more than y8" from a true circle and that might cause the inner surface decay. This coin- shall: be free from pound is therefore dents or other ob- a thorough pre-: servatitfe,. and. is a Iso' insu 1 atioh arid waterproofing. It thoroughly pei>:: fneates the entire structure, . so that, after treatment the wall of; the con duit, when cut, presents a strong resemblance to hard rubber. The ends are tooled in a lathe to make Socket or Har rington joint, as may be desired. Stock is stored in winter and sum mer in the open yards of the manfacturing plant. Fibre Conduit installation by "built-up" method. Grooved moulded concrete separators hold tiers of conduit in posi tion to pour concrete in a single operation. structions, as gauged by' ability to: pass a 36'' long mandrel of less diameter than the nominal size of the conduit. : 5. The i.nne: surface shall b< free from excesi surface o f com pound and fron r o ugh or flak} areas. 6. On size: from 2'' insidt diameter to 4%' inside diameter lengths shall be ! ft., with the excep tion of not mor< than 15% whicl may be furnishec in lengths shortei 231 CRMC-003595 Johns-Manville Service to Railroads than 5 ft. but not less than 3 feet. On sizes 1". and 1%" inside diameter as sorted lengths shall be furnished from 2y2 ft. to 5 ft. in multiples of 6". The Harrington Joint Type This type of joint is made with both ends tapered. The sleeves are also tapered, there by allowing more ``swing'5 to the conduit Types of Joints than can be secured by other types of joints. With this type the conduit does not butt, permitting greater flexibility. Orangeburg Fibre Conduit, Bends and Fittings are made with two types of Special Sizes of Fibre Conduit joints; namely, Socket and Harrington. Fibre conduit can be made on special Each type has its advantages for certain order up to 18 inches in inside diameter. different types of applications. List prices For prices and delivery on special material are given in the succeeding pages. Prices apply to the nearest Johns - Manville and promises of delivery on special Branch. material can be secured from the nearest Special Bends Johns-Manville Branch. Special bends can be formed to dimen sions desired, The Socket Joint Type The/Socket or mortise, and ten'on: -connections that are. cut on ;: the ends; of each;, length of .Socket:/ Joint v Orange- ; burg Fibre' Con duit are ; autom a; t i c a 1 1 y turned, slightly tapering and uniform in size. Fibre Conduit incorporated in retaining wall. within the limits given in the table below, if not mitred. If mitred any de gree or radius desired may be obtained and the bend can be made anywhere in length of standard pipe. These bends are made only to . order. As the joints are automatically formed, the connection secured in laying the con duit is perfect in fit and alignment. The inside of the joint is reamed during the process of cutting so that there can be no offset at the joints when laid. The flange of this joint also serves to exclude the cement when concrete is poured. SWEEP BENDS Not Mitred I- D. in Shortest Radius Incnes Inches 1 .... 8 ........ 12 2 ........ 18 2/2 ........ 24 3 ........ 30 3 54 . ........ 36 4 ........ 36 454 ........ 36 "S" BENDS I. D. in _ Max. off- Not Mitred Inches set, Ins. 1 .. . 16 .. . 8 Wz ... 36 .. .. 18 2 ... 36 . 18 2'A . .. . 28 . . . 24 3 ... 24 .. . 36 . .. . 20 . . 36 4 .. . 20 . . . . 36 41 < . . . 20 . . . . 36 232 CRMC-003596 Johns-Manville Service to Railroads Advantages of Fibre Conduit the sheath becomes seriously abraded 1. Low initial cost. Small percentage w; or cut. Orangeburg Fibre Conduit of breakage. Low freight cost per foot. joints prevent seepage of concrete. Minimum space in duct line. Easy to Lack of protection to the cable in the handle. Low cost of finished duct. duct is usually in the form of loose and 2. Strength. Building excavations and non-waterproof joints which allow stray short circuits have the minimum amount currents access to the cable. of damaging effect on fibre conduit. Orangeburg Fibre Conduit when prop 3. Ease of cut erly laid provides ting and con a duct in which necting into a all joints are fibre duct; and watertight. Ad ease of avoiding vantages of this obstacles. are obvious 4. Ease of pul where electroly ling cable in or sis is likely to out -- minimum prevail. of damage to cable. Uses of 5. Ducts can Orangeburg be spread to en Fibre Conduit ter manholes. 6. Damaged duct r em a i n s useable ."after, .se? verecablefailure. 7. Can be in Installatiori.'. of ' Fibre .'Conduit,, Switchboard : Floor, between lines-."E" and .-`F'V at' United'Electric Company, Springfield., Mass., Stone and-Webster, Inc.,' Engineers .and Contractors.' While the largest field of application for Ora n g e bur g .Fibre Conduit has been in elec- stalled "rapidly -AA'", trie service un --an advantage in :a.busy street. ... j. derground-systems,; this product: has also- 8. Will not warp,-".'stick.. or. grip cable,;, been applied satisfactorily in many special either-from the effect, of 'moisture or heat. fields. I.t has been; used as a conduit for . Checks fire, in case of; arcing. "< " electric conductors on electrified railways; Protection of Cables it has been laid in concrete forms for com ducting power house cable systems and for It is a recognized fact that about 90 per cent of all underground cable trouble is directly traceable to some injury to the lead casing of the cable, which takes place when the cable is being drawn into the duct; or to lack of protection which should be afforded to the cable after being placed in the conduit. The injuries to the cable leaders from aerial lines to underground ducts. In addition to this, certain other special applications have been successfully tried but it is recommended that before Fibre Conduit be purchased for applica tions other than the above, the matter be taken up with the nearest Johns-Manville Branch. while being drawn in are usually caused by burrs or blisters on the interior of the Approved by the Underwriters conduit, or to nipples of concrete that The Underwriters' Laboratories, Inc., have seeped through the joints, formed have approved Orangeburg Fibre Conduit and hardened on the bottom of the duct. for use in electrical generating and sub In drawing the cable over these defects stations when laid in concrete. 233 CRMC-003597 Johns-Manville Service to Railroads Price List--Schedule "A" Covering Standard Material Prices F. 0. B. Factory Subject to Change Without Xotice AN EXTRA CHARGE WILL BE MADE FOR BENDS OF SPECIAL DEGREE OR RADIOS, FOR CUTTING TO SPECIAL LENGTH, FURNISHING MATERIAL TO SKETCH AND MATERIAL COT TO WASTE Inside FIBRE CONDUIT Diameter, Inches Price per Foot Standard Crate contains, Feet Approximate Gross Weight Standard Crate, Pounds Approximate No. of Feet Minimum Carload 30,000 Lbs. Socket Joint 2 So. 10 200 270 33000 2H .11 200 320 27000 3 .12 150 285 22800 3H .13 125 290 19800 4 .15 100 280 16000 4H . 19 100 330 13200 2 SO. 13 200 295 31300 Harrington 2'A . 14 200 355 24750 Joint 3 .15 150 320 21250 3H .16 125 320 18000 Coupling Included with 4 .18 100 320 14850 AU . .23- 100 380 12000 Maximum No. of Feet in 36 Ft. Car Approximate Gross Weight Maximum Quantity 36 Ft. Car, Lbs. Approximate Net Weight per Foot, Pounds 35000 30000 25000 21000 16500 13300 31800 33250 32800 31800 30800 30250 0.90 1.10 1.30 1.50 1.85 2.25 33000 27000 23000 20000 16000 12000 31600 32700 32500 . 33300 32300 30000 0.95 1.20 1.40 . 1.65 2.00 2.50, . BENDS. AND FITTINGS Inside Diameter, Inches . . Standard Bends,'.Each ...Standard Crate, of Bends' contains . Pieces Approximate. Gross Weight Standard Crate Bends, Pounds Radius, . Standard . 45= &,90";' .Bends . Radius,/ 1 Standard ... ^`S'-.'Behds ' i.20" Offset i Elbows,, , -Each Extra Couplings.' Each ' Socket-. . Joint:. .'Si:. 75'; ' ' -2-hL:. . 1:80 :'X: a 1785 . .. 3K . 2 : 00 . .'4 7 2. 25: ' A1 2 ; ..3.25 ' 25 25 20: .15 12 9 255 295 280 295 295 250 - 18"-24-`-36,/ 2.4':-36" ' -36'" -36"".': 36". - 36" 36" "; v- 367 ' 36"... " 36" "' 36" 36" S2.15 2.15 : 2.20 . 2.20 7 2 .25 3.00 ' 2 $1V90 ' 25 265 18"-24"-36" ; 36" Harrington " 2J2 -.'2.00 25 310 24"-36" . 36" 3 2.10 20 290 36" 36" . 3 Vo 2.30 .15 - 310 36" 36" Coupling Included with Each Bend or Kitting 4 41 2 60 3.65 12 9 305 260 36" 36" 36" 36" $2.25 ; 2.25 2.35 2.35 2.45 3.25 .$0.10 .11 -12 .14 .16 .20 it.cy.zr joixt type 234 karrixcto.v joint tvpe CRMC-003598 Johns-Manville Service to Railroads A Few Standard Bends 45 Bend--5' Long, 36" Radius--Socket Joint "S" Type Bend--Socket Joint 90 Bend--5' Long, 36" Radius--Socket Joint Elbows Dimensions below are in inches and only approximate: 4 90 ELBOW : 45' ELBOW D 2" 2A 3 314 4 Ay2. 2 2J4 3 3$4 :-;4 4J4 ;r . ill e - 'G 2y2 214 3 6 6^ 6# 3 3A 4A:2A 2A 3 .3- 314 414 7 7A s: '8# .9. 9 9y2 10* 12 .Socket Joint T J4; A A A A ft.- A \A A. A iV Harrington Joint L 14 14 A A A A:: !4 A A 14 14 A Trade Customs The right is reserved to ship from any of our plants. Sales subject to strikes, accidents or causes beyond our control. Every piece of conduit is carefully inspected, but as it is impossible always to detect imperfections, the only guarantee that is given by us is to replace such goods as prove defective or allow credit for such goods at our option. Under no circumstances are we responsible for any damages beyond the price of the goods. No charge for labor or expense will be allowed. If the goods are defective, the measure of damages is the price of the defective pieces. No material will be taken back and credited or re placed unless arrangements for such return have previ ously been made. The carriers are responsible for the goods lost or damaged in transit, therefore, as required in Rule 3 of Uniform Bill of Lading, in case of loss or damages en route, consignee must immediately notify the railroad agent at destination in writing in order to substantiate formal claim when presented. Claims for shortage or deductions or erroneous charges must be promptly presented with full details or will not be allowed. Special goods made to specification, where buyer is to inspect, must be inspected and accepted before ship ment is made. After shipment is made, our respon sibility ceases. Requests for cancellation of orders calling for odd sizes or cut lengths, will not be considered if the man ufacture of the material has been commenced when the request reaches the mill. 235 CRMC-003599 Johns~Manville Service to Railroads (Pat. App. For) JOHNS - MAN VILLE INC.,- Sole Selling Agents A flexible system of distribution for service ^vires through ducts integral with the concrete floor RANGEBURG underfloor duct sys- O tern molds a network of wire tun nels in the concrete floors of mod- Description: The system consists of fibre ducts laid in the Concrete of the floor in parallel lines sufficiently close one to ; erri firesafe buildings which by such intchlueother that, wherever electrical machin sion become ah integral part of the struc ery or apparatus may be placed, it will be ture. The specification of this system obvi ates for all time mutilation of walls arid floors; reduces to practically the bare cost of the wire itself the expense of additional electrical facilities or the rearrangement over one of such lines. At convenient dis tances and at right angles are constructed header lines of the same duct, connected to these distributing lines and extended to the floor wiring centres. To the duct, ac of old; removes the hazard of exposed cess is had through an insert or outlet fit wires, their unsightliness and the failure ting placed through the finished floor and of the apparatus they serve, through their floor covering. Such outlets are only es liability to interference and damage; and tablished as needed and if subsequently makes available for electric service every abandoned are closed in a simple manner, possible location at which apparatus or being, however, immediately available if equipment may be wanted. wanted again. 236 CRMC-003600 Johns-Manville Service to Railroads where service might be required at least twice as many outlets have been installed as were finally used. In the Orangeburg system no outlets and no wire are installed until service is required and then only for the necessary requirements. Subsequent additions are as cheaply made as would have been the case had they been included in the original installation. Two systems are offered: a double duct Showing installation of Orangeburg System of Underfloor Duct in a floor of over 3" fill. Note "pad" or "bench" provided under duct and inconspicuous floor outlet. for heavy duty and a single duct for lesser requirements. In the double duct system, two ducts are run side by side at the agreed spacing be Duct: Is the well known Orangeburg tween the parallels: one duct for electric Fibre Conduit which through a quarter of light and power wires, one duct for signal a century has come to be the standard of and communication wires. subway construction, for almost the entire In the single duct system all wiring is electric light and power and electric rail- carried in one duct. way industries. Confidence in its . It is recommended that the paral- durability is assured by this record . lels of the system be spaced from 5 to as its placement in floors (imbedded : 6 feet apart, the first and last parallels in concrete) is identical with . its y from 2% to 3 feet from the adjacent treatment'in Subway construction. wall. ; . . : Jundiion.Soxes .* Of cast iron with brass Headers should be spaced solely on a tops, and covers ; , strong and .rugged ; will.; basis of estimated wire density, as wire withstand- rust, and corrosion equally;vfith can be fished to any distance met with in the building frame; and a rload- weight the floor areas of modern buildings. equal to the floor in which they are im bedded;.- Outlet Fittings : Of cast brass of ade quate design to withstand the; compres sion in the top of floor slab in which they are placed. Wafer .Exclusion.* Both junction boxes and outlet fittings are provided with dur able gaskets making certain watertight joints at the floor line. Design The Orangeburg system distinctly mer its consideration from this point as it en tirely eliminates guesswork in planning. In systems previously used it has been necessary to install duct, outlet fixtures and wire previous to the occupation of the building. Further, in guessing as to Installation showing crossunder fitting used when piping crosses the Orangeburg System of Underfloor Duct installation. 237 CRMC-003601 Johns-Manyille Service to Railroads Standard size the ceiling below. ducts used in the A reasonable num Orangeburg Under ber can be accom floor Duct System modated by a spec are 4%" wide and ial cast iron cross- 2-J4" high over all under fitting which and have been in is installed in the stalled with entire satisfaction in build duct line and offsets the line down about ings with floor fills of only 3". How ever, in most office buildings a fill of A typical floor plan of duct layout in the American Telephone & Telegraph Company's office building in New York City; 22 stories fitted with Orangeburg Underfloor Duct; complete installation. 2 leaving a space 4wide and the entire height of the fill through 4y2" to 6" is generally provided. which pipes may be run as shown on Where the fill is greater than 3%" a page 237. concrete "pad" or "bench" should be pro vided so that when the ducts are installed Finish on top of the pad the top of the duct will In designing the fittings and duct full be about 1" or 1%" from the finished floor consideration has been given to both util surface. (See illustration on page 237.) ity and appearance. The finished floor is This facilitates the installation of neat in appearance and in satisfying fittings and also raises the ducts contrast to the results obtained with above the floor slab so that other other methods of interior wire distri pipes can cross under the ducts by bution. cutting through the pads. ; Where a fill of only 3" or 314" is provided For details and specifications of the any. pipes. which must? cros? the path pf Orangeburg System, apply to the nearest the ducts should' preferably be cast.in the Johns - Manville . branch or write, dor concrete floor construction, or installed on pamphlet E-30. , j . .p SYSTEM IN REINFORCED CONCRETE Closed-bottom Duct installed in Office Building, Long Island Railroad Co., Morris Park, N. Y.; Hatzel & Buehler, Inc., Elec. Contractors. SYSTEM IN FLOOR FILL Installation in Western Electric Warehouse Building, N. Y. C-; double grid layout; J. P. Hall-Smith Co., Electrical Contractors. 238 CRMC-003602 Johns-Manville Service to Railroads CRMC-003603 OflAKGftU Johns-Manville Service to Railroads 240 CRMC-003604 Johns-Manville Service to Railroads Johns-Manville Friction Tapes JOMANCO FRICTION TAPE A(;rt*C9 v. * -O'* *' Johns-Manville, Inc. Atb&u Cottuobo Itaaphis -rimliriiitti Haitimore Pis^er -l. -- JCBirufett - < ^rtUaOv*r- Bo<on DefcoSi Brulalo 71tt\ wwk.J. 8thUeCSt? Chicago \ ySa J WOtWs fiuFr*ad*oJ CitKiredi Ktaa< CSty VJrV HeTi . Se*ffVi. . - .C!*T*ai 'L* Os&Jii* * ; . W*to."::.y." ; l4d*vt& Fhiid^phte ^ , Careful manufacture of selected materials assures the highest quality in Johns-Manville Friction Tapes. They are better, more satisfactory and more durable in every way.* OHNS-MANVILLE Friction Tapes : class of insulated joint is required. It is J : are made of strong,: closely woven fab-. preferred by manufacturers of high-grade ric, heavily impregnated with a specials electrical machinery because of its ability ly treated compound. They have remark- to withstand high voltages. Used for all . able ,adhesive properties and long; life; purposes under the most exacting condi- are not affected by heat, cold or moisture; tions, it has never been known to fail, do not dry out with age; contain nothing .. Johns-Manville No. 3 Tape-A popular to,corrode wires; are free from pin-holes, material for taping motor leads, switch- lumps and thin spots and have exceptional- boards and inside wiring where a good in- , insulating efficiency, due to the heavy and. sulation is required. Strong in friction, even saturation;' They, contain the maxi- possesses high heat - retarding qualities mum yardage per pound.. and dielectric strength. Johns-Man vi 11 e Friction Tapes . are \ Johns-ManvilleNo. 5Friction Tape-A three-fourths, of. an inch wide and are put good grade for standard electrical work up in standard 4-ourice and 8-ounce rolls, and other miscellaneous and domestic wrapped in tin-foil and packed in strong uses; free from surface defects. Shows Manila paper cartons. little or no deterioration for a year, if Jomanco--Gray in color', is the high- stored under proper conditions, est grade of friction tape on the market, Johns-Manville Armature 'Tape--Made and is recommended for permanent un- from thin, closely woven sheeting of high- derground, subway, mines, railway signal, est quality, frictioned on one side only, sign, wireless telegraph systems and gen- Suitable for winding armatures, field coils, eral out-door work, where the highest etc. `Johns-Manville Friction Tapes are standard with many of the largest steam and electric railroads in the United States. These are guaranteed tapes and with the ex ception of Johns-Manville Armature Tape will be re placed if found defective within one year from date of manufacture. Prompt shipment can be made from adequate stocks in all important cities in the United States and Canada. 241 CRMC-003605 Johns-Manville Service to Railroads Johns-Manville Rubber Splicing Compound ADE of Para rubber scientifically M compounded so that it does not dry out. When applied it forms in 4-oz. and 8-oz. rolls, wrapped in tin-foil and packed in Manila paper cartons. Alpha Brand--A splicing compound a homogeneous mass without the aidofothf e highest grade. It assures absolutely heat, making watertight joints that last perfect joints, is impervious to moisture indefinitely. and stronger dielectrically and mechani cally than the insulation of the wire itself. Uniform in thickness throughout -- no Will stand a test of 300 volts per mil. lumps or thin spots -- and it has ex Brooklyn Brand -- A good splicing ceptional strength. Furnished in two compound recommended for low voltage brands, Alpha and Brooklyn, %" wide, work. Johns-Manville Asbestos Braided Tubing This tubing is largely used for insula- It is absolutely fireproof and has been ting conductor wires, of arc lamps and for in constant use for many years, during covering electrical wires where, superiorwhich it has never burned out, thereby fireproof protection is required. causing a short circuit. This material is extremely flexible; it can easily be made impervious to mois ture, and is permanently durable. i Some of the stees in which Braided Asbestos Tubing is made. No. of . Tubing To fit . over Wire N.o. . Approximate Outside Approx. iN.o ..List1' Diameter Lineal Ft; Price, of .Tutiing Per .Round Per,Round: 1 1516 1517 ' 1518 1519 1520 .1521. 1522 1523 1524 1528 1529 1530 1531 1532 ' 17 B. & S. . 10B. &S. 8 B. & S. 5 B. & S. 4 B. & S. 2 B. & S. OB. &S. : 1 >" 175 $4.00 - 100: , 4:00 -io" 85 4.0Q t" " .65 4.00 Vs" 50 3.00 46 ' 7 3.00 1AH 22 3.00 >/" 20 3.00 Mir," 16 3.00 T" 15 3.00 Vs" 13 3.00 1" 12 3.00 IT" 10 3.00 \yy 9 3.00 Other diameters made to order; also any form of braiding desired. 242 CRMC-003606 Johns-Manville Service to Railroads Johns-Manville Niagrite and Asbestoment Fireproof Cable Insulation The illustration shows the slight effect of an electric arc at a voltage of from 90 to 110 and a current of from 400 to 2000 amperes, the electrodes placed J/n" below the test piece. It was intended to reproduce the destructive action which might be expected should an arc occur in the cable adjacent to the one on which the fireproofing was being tested. The arc was sustained for a period of two minutes. It has been estimated that the temperature at the crater was from 3500 to 4000 F., the temperature falling off slightly at the higher voltage. During the test the thermo-couple showed the temperature rise in the tested cable over 75 F. within the bounds of safety. HE Johns-Manville Niagrite-Asbes to a thick paste, is then applied by hand Ttoment Method of fireproofing cables has been developed to protect valu to a thickness of approximately When dried, which takes approximately able cable equipment from the destructifvoer,ty-eight hours under normal air condi action of an arc occurring in adjacent con-. tions, the Asbestoment sets and becomes ductors, It is. used, wherever cables of adamantine with age. Moisture or even . high. potential are: exposed, . particularly immersion indefinitely has no effect on it. in manholes where splices are located, or. It may be applied 50 Ac faster than any where feeder cables are trained to the back other form of cable fireproofing and will of switchboards. . .A. allow greater freedom in bending cables Its components are Johns-Manville' without cracking the fireproofing than any Niagrite and. Johns-Mariville ^ Asbesto other known form of. cable protection. ment. Niagrite is an:.asbestos felted'ma terial . backed with asbestos cloth, made in the form of .a -tape, in rolls 15 feet long: and in ail thicknesses from to The best standard construction is a double layer of G" thickness. A roll of this tape is loosened and immersed for about twenty minutes in a solution of Johns-Manville Asbestoment. This is a special super-re fractory cement, chemically neutral. Both these materials are free from ingredients which might corrode lead cable sheathing. When the Niagrite tape has been thoroughly moistened with the cementing material, it is applied directly to the cable, being wound spirally with butted joints. The second layer should be applied with . It has superior thermal conductivity' so that heat, within the cable is led away more rapidly than by muslin, paper or the rubber insulation nearest the copper con ductors. This Niagrite-Asbestoment combina tion has been tested under actual manhole conditions by some of the largest com panies in the United States. (See test.) This is assurance that this combination will prevent communication of burnouts where cables are exposed to an arc occur ring in adjacent circuits. The resulting saving in valuable equipment and contin uity of service is well worth the moderate cost of such an installation. joints midway between joints of the initial The nearest Johns-Manville office will layer, which makes for greater strength. be pleased to offer further suggestions as An outer covering of Asbestoment, mixed to cable equipment protection. 243 CRMC-003607 Johns-Manville Service to Railroads Johns-Manville Third-Rail Covering Special covering for the bonded fish plate joints. Straight section for rail covering. (As used by Philadelphia Rapid Transit Co.) Covering of the T . rail in the' conddit ' of .the Surface.road of New York City.' Wilgus Under-run ning third-rail cov ered with indurated fibre covering. Transmission rail of . the Elevated and the New York Subway: .'.The exposed parts covered by indurated .fibre material. . 1 ,^QR. many years we have, supplied a cluding the maker's name; section number P weatherproof covering made of .fibre and full size, sketch of. the rail, together and impregnated with .a high quality . with quantities and delivery desired. Pres of : asphalt, for .enclosing the feed rail of. ent factory equipment will produce several electric railways. pf the more popular types, but. where Recent specifications have called for im : special material is required, a nominal, pre sulatipn to cover the sides and top of liminary charge may be made. power rail, the contact being from the un der side. To take care of the joints be tween rail lengths, enlarged sections have been developed which allow suffi cient room to cover the fish plates, bolts and hangers, as shown above, but material can be furnished for practically any type of installation. Johns-Manville Third Rail Insulation is the most modern protection so far devel oped; it has ample dielectric strength; provides a complete cover, if desired; will effect large savings through protecting power rails from ice coating in the north ern latitudes; presents a most pleasing and ornamental appearance and, unlike All inquiries sent in should include com wood covering, will withstand the ele plete information as to use and service, in ments indefinitely. Price on application. 244 CRMC-003608 Johns-Martville Service to Railroads Johns-Manville Success Chemical Fire Extinguishers Approved and labelled by the Underwriters' Laboratories, Inc. Automatic Type Hand-Pumped Style (Non-Freezing) Johns-Manville Success Fire Extin guisher is made of extra heavy, cold rolled, Lake Superior copper. Starts and stops simply by reversing the position, of the extinguisher. An effective fire-fighting apparatus that can be easily handled, operated and re charged. Throws a high pressure stream for dis tances up to 50 ft. Ex tinguishes benzine, naphtha, tar and other flames on which water has practically no effect. It is superior to others for the following reasons: All joints are securely riveted ;and. reinforced, by heavy shoulders. of solder.; Tested to a pressure of 350 lbs. to the square inch; ---four times .'the Made with a standard, size bottle- andcast brass bottle holder,' instead of the flimsy brass wire .holder ordinarily used. The Johns-Manville Success NonFreezing Fire Extinguisher will not freeze at any temperature above forty de grees below zero. It will afford unfailing protection from fire at all times, particu larly when other fire extinguishers, as well as water pipes, would be frozen up and out of commission. Easily portable and can be operated by anyone. A pliable rubber hose makes it possible to aim the stream in any direction without moving the extinguisher. Throws a continuous stream fifty or sixty feet. Has a 2% gallon capacity, suf ficient for most incipient fires. Tank is made of copper, protected by a double application of lead-tin alloy and a coating of "Insulite," an asphaltic base, paint. Double acting pump is made of seamless brass tubing. Pump plunger made of a special alloy not affected by the solution. . Tested by the .Under writers' Laboratories, Inc., by being operated 73,000 strokes and remained in good working order. Also a unique bottle stopper which regulates the flow of sulphuric acid into the bicarbonate of soda thus generating the correct amount of gas at all times. This avoids explosion--which is possible in extinguishers where total quantity of both liquids is mixed at once. The Johns-Manville Success Fire-Ex tinguisher meets every requirement of de pendability and durability. To operate: withdraw the metal pin holding the pump handle which releases the pump and permits im mediate use. Recharged by pouring solution through filler opening. No recharg ing necessary until contents have been discharged, as so lution will not deteriorate. 245 CRMC-003609 Johns-Manville Service to Railroads Johns-Manville Asbestos Lead Joint Runner Runner equipped with spring clamp. OR making lead joints in cast-iron Fgas and water pipes, Johns-Manville Asbestos Lead Joint Runner is the most practical device on the market. is composed of specially prepared asbestos rope, of square cross-section, having a fer rule on each end and. provided with a clamping device for fastening in place on the pipe as shown, in the above illustra tions; The rope used is solid asbestos, containing no core1 of jute br other com bustible material. Owing to the shape of this device and its flexibility, it covers the pipe joint snug ly, so that there is no leakage of lead nor aInty unnecessary lead left protruding from the joint to be chipped off afterwards. Being made of asbestos, it will not char or burn from contact with molten metal. The ferrules are of: such design that they cannot be pulled off. The clamp is of simple construction and practically inde structible. ASBESTOS .RUNNERS FOR VARIOUS SIZES OF PIPE No. ..'I 0..............Rope ./ 44 inch square, for. 2, 3 and 4 inch pipe 2 , ........... Rope ;r. 44'inch square, for' 4, 5 and 6. inch pipe ' 3 . . ..............Rope T inch square, for 6, 8: and 10 inch pipe 4 ; ........... Rope U : inch square, for 10, 12 and 14 inch pipe - 5 . . .. Rope :144 inch square, for 16, 18 and 20 inch pipe 6 . ............ Rope'444 inch square, for 24 inch pipe 7- . ................ Rope, 1*4 inch square, for 8 ................ Rope 1 j/j-inch square, for 48 inch pipe ; 42 inch pipe 9 ; , ........... Rope 144 inch square, for 36 inch pipe 10 . ............. Rope 144 inch square, for 30 inch pipe. Johns -Manville Asbestos Clothing We are prepared to furnish Asbestos Clothing of any de scription, and in any quantity. This clothing is made up in standard clothing sizes. The following list covers articles which will be made up according to any desired specifications: Aprons Arm protectors Caps Coats Gloves Gaiters Helmets Overalls Jumpers Leggins Mittens Shoes 246 A suit of Johns-Manville Asbestos Clothing com plete with helmet, gloves and gaiters, CRMC-003610 CRMC-003611 Johns-Manville Service to Railroads How to Use Tables of Pipe Insulation Efficiencies The efficiencies of pipe insulations vary ac cording to the size of the pipe insulated and ac cording to the temperature difference between steam in the pipe and air surrounding the pipe. The relative values of different insulations may be determined by comparing either their effi ciencies or the heat losses through the various types of insulation. The efficiencies furnish a means of comparing the savings effected by insulations with bare pipe losses. These latter are very large; there fore, a seemingly small difference in efficiency may represent a really large difference in heat losses. The heat losses may be compared directly as follows: Bare surface loss............................= 100% Efficiency' ................ .... .............. .=Percent saving 100%--% Efficiency = Loss through, insulation expressed as a percentage of bare surface loss. For example, an insulation which is. 90% effi cient allows a loss of only 10% of the loss from bare surface. EXAMPLE:--The efficiency of 2" thick AsbestoSponge Felted Sheet Insulation at 500 temperature difference is 95.44% and the efficiency of the same in sulation 3" thick is 96.85%. The difference in efficien cies is only 1.41% which seems extremely small and might lead one to believe that it would not pay to use the extra inch of thickness. However, the loss through the 95.44% efficient insula tion is 4.56% of the loss from bare surface and the loss through the 96.85% efficient insulation is 3.15% of the loss from bare surface. The difference 4.56%--3.15% = 1.41%. Therefore, the loss through the 2" thickness is (1.41 -4--3.15=) 45% greater than the loss through the in sulation 3" in thickness. The table on page 249 gives the total heat losses at various temperature differences on bare pipe of different sizes, and on fiat surfaces. Tables of efficiencies of the different insulations on vari ous sized pipes and on flat surfaces at various temperature differences are given following the pages describing the insulations. Use such efficiency tables as follows: Example What is the efficiency of: Johns-Manville :Asbesto-Sponge Felted Pipe Insulation .2. inches thick, to be applied on a 6-inch pipe conveying steam at 200 pounds gauge -pressure through a room where temperature is'7.0 -F,,? 1. . Determine;, difference between temperature of steam in pipe and , air surrounding pipe (see Steam-Tables, pages.249 to 252.. ' Temperature of steam 200 lb. pressure 388 F. Temperature of air around pipe......: 70 F. Difference .......................................... .. 318 F. 2. Refer to Table of Efficiencies for 2". thick Asbesto-Sponge Felted Pipe Insulation. Opposite pipe size (6"), you find Efficiency for 350 F. difference.............. 92.6% for 300 F. difference............. 91.9%. Difference for 50 ...................................... .7% If difference for 50= .7% then for 1 difference is .7-t-50=.014%. The difference you have (318) is 18 more than 300, so 18 x .014=.252% which, added to 91.9% (efficiency for 300)=92.15% the required effi ciency. If you desire to find exactly how much heat, is. saved by applying this 2" insulation, proceed as follows : 1. Refer to table giving total , heat loss .in B.t.u. per lineal foot of bare pipe .(page 249). Opposite pipe size (6") and under. 300 differ-, enc.e you find loss is 1694.9 - B.t.u. per hour. ..Under 350 difference the loss is. 2198.7 B.t.u. Difference in loss, for the 50 difference=2198.7-- 1694.9=503.8 B.t.u. and for Is difference it is 503.8-4-50=10.07 B.t.u. The difference you have (318) is 18 more than 300, so 18 x 10.07 = 181.3 B.t.u., which added to 1694.9=1876.2 B.t.u., the required total heat loss from 1 lineal foot of the 6" bare pipe per hour. Having obtained the loss for bare pipe the sav ing effected by the 2" Asbesto-Sponge Felted Insulation is obtained by multiplying the total loss 1876.2 B.t.u. by the efficiency of the insula tion formerly found (92.15%) or 92.15 x 1876.2 = 1729 B.t.u. saved per lineal foot per hour. This result may be compared with the quanti ties of heat saved by other types or thicknesses of pipe insulations which quantities may be ob tained in similar manner to the above. 248 CRMC-003612 Johns-Manville Service to Railroads Total Heat Loss in B. t. u. Per Hour Per Lineal Foot of Bare Pipe of Different Sizes, and Per Square Foot of Flat Surfaces, at Various Temperature Differences (For finding losses at temperatures between those shown, the B. 1.1 Differences per Degree are given in small type between the Ma in Columns) Temperature Differences Pipe Sur- 50 100 150 200 250 300 350 Pipe face per Heat Loss in B. t. u. per lineal ft. per Hour 79.2 *-6 117.3 *.90 162.3 *1.03 215.2 *1.28 279.1 1.54 355.1 1-93 451.4 *2-37 3' " .274 26.8 -64 59.0 98.6 146.8 1.11 202.1 1.33 268.5 1.3S 347.6 I,S9 442.2 z.40 2.95 .344 33.6 .Si 74.0 X.00 123.8 t-19 183.4 t.41 253.7 1.D7 337.4 1.98 2-37 3.03 3-69 i >r 15." 2" .435 .498 .622 42.5 93.6 48.7 107.2 60.9 1.46 133.9 3.26 I.So 156.6 179.3 223.9 2-13 231.9 1.78 265.4 2.04 331.5 2.54 320.8 j.o9 367.3 2.39 458.7 2.99 425.4 2-53 487. 2-90 608.3 3-62 SSI.9 3-00 3-44 4-29 702.1 3.So 4-36 5-45 892.6 4.68 5-30 6.0Q 1126.7 2;:.~ 3" 3);" 1.76 161.6 89.6 197.3 1.047 102.3 2.46 225.3 2.18 2.66 3.03 270.4 330.1 376.9 3-62 400.3 3.07 488.8 3-73 558.1 4-2S 553.9 3.01 676.3 4.41 772.2 3.04 734 .S 896.8 1024. 4-37 952.8 5-33 1163.4 6.09 1328.4 5. IO 1212.1 0.33 -.43 6.5S 1541.1 8.0S 8.03 9.S; 9-17 11.3 1945.1 4" 1.178 115.1 n -- 2S3.5 424.2 627.9 4.S2 868.8 s-t: 1152.1 6.S3 1494.6 s.13 1901.3 10.3 2417.3 12.7 3051. 4 > 1.309 127.9 281.5 470.9 697.2 5.35 964.7 0.20 1279.2 7.0i 1659.5 0.03 5" 1.456 142.2 3.42 313.1 4.21 S23.8 3.03 775.5 5*95 1073. 700 1423. S.46 1846. 20.0 n.05 52.7 14.1 15-7 3768.5 6" 1.734 169.4 371.9 623.9 923.7 7.09 1278.1 S.34 1694.9 10.1 2198.7 12.0 2797.1 15-2 3556.2 IS.6 4488.5 1066.0 S.n 1475.6 o.-.t 1956. 11.66 2539. 13.7S 17.46 21.6 8" 2.257 220.6 5-30 485.7 6.54 812.5 7.Si 1203. 9.23 1664.5 to.5 2207.3 13-1 2863.6 15.6 3642.8 19-S 4631.4 24.3 9" 2.52 246.0 542. 907. 8.72 1343. 10.34 1860. 12.t 246S. 14.7 3200. 17.4 4070. 24.0 5170. 27.3 6530. 10" 2.817 275.4 606.2 s.16 1014.1 1501.5 11.3 2077.5 13.6 2755. 16.4 3574.1 19-5 24-7 30.3 11" 3.08 300. 7.26 663. s.92 1109. 10.66 1642. 12.6 2272. 14.76 3010. >7-9 390S. 21.3 20.9 33-3 12" 3.34 326. 14"o. d. 3.66 16"o. c. 4.19 408. 719. 786. `>.S4 901. 12.2 1203. 1318. 1510. ,, 12.04 Uo 1780. 1950. 2233. 13.7 13.0 17.2 2465. 2700. 3095. 16.02 3266. 17 05 3580. 20.1 4100. 19.4 21.3 44-4 4235. 4645. 23-1 2 t.? ?s.g 5390. 6/65. 29.2 31.9 3t-3 6850. 30*0 39-5 45-2 8650. Surfaces. 97.5 2-35 215.2 ' 2.f)0 360.0 7.an (. 1.950 2.1S2 2.400 . 533.0 2.665 u. per sq. ft. per Hour 4-to 737.8 4 978.0 5.S3 269.4 6.80 1614.0 per degree temperature difference per Hour 2.951 3.260 2" Pit e, 235 5 Temp. Difference. 235 r -- 200 " = 35: 3 5 x 2.S4 (B. . u. per degree) =88.9 B. t. 1 . 331. -r88.9 = 420 4 : B. t u. loss at 235* Temp. difference. Steam Table Reprinted from Marks '& Davis' Steam Tables and Diagrams, by permission of the publishers, Longmans, Qreen & Company V ; Press. lbs. - `p ' 1- .0 .3 4.3 S 6 8 9 10 11 12 14 14.7 15 16 17 18 19 9.3 24 Deg: T. t 101,83 126.15 T41.52 162.28 170.06 176.85 182.86 188.'27 193.22 197.75 201.96 205J87 209.55 212.00 213.0 216.3 219.4 222.4 225.2 228.0 230.6 233.1 235.S 237.8 Press. Atmos* ' ---- 0.068 0.136 0.204 0.272 0.340 'Sp.Vol. Density" cu. ft.- lbs: per .-per !b. CU.'ft . v or s ' . v. 333.0 173.5 118.5 90.5 73:33 0.00300 0.00576 0.00845 0;01107 0.01364 ' Heat of the liquid h or q 69.8 94.0 109.4 120.9 130.1 0.408 0.476 0.544 0.612 0.680 61.89 53.56 ' 47.27 42.36 38.38 0.01616 0.01867 0:02 US 0.02261 0.02606 137.9 144.7 150.8 156.2 161.1 0.748 0.816 0.885 0.953 1.000 35.10 32.36 30.03 28.02 26.79 0.02849 0.03090 0.03330 0.03569 0.03732 16S.7 169.9 173.8 177.5 180.0 1.021 1.089 1.157 1.225 1.293 26.27 24.79 23.38 22.16 21.07 0.03806 0.04042 0.04277 0.04512 0.04746 181.0 184.4 187.5 190.5 193.4 1.361 1.429 1.497 1.S65 1.633 20.08 19.18 18.37 17.62 16.93 0.04980 0.05213 0.05445 0.05676 0.05907 196.1 198.8 201.3 203.8 206.1 Latent heat of evap. L or r 1034.6' 1021.0 1012.3 100S.7 1000.3 995.8 991.8 988.2 98S.0 982.0 979.2 976.6 974.2 971.9 970.4 969.7 967.6 96S.6 963.7 961.8 960.0 958.3 956.7 9S5.1 953.S Total heat of steam H: 1104.4 1115.0 1121.6 1126.5 1130.5 1133.7 1136.5 1139.0 1141.1 1143.1 1144.9 1146.S 1146.0 1149.4 1150.4 1150.7 1152.0 1153.1 1154.2 1155.2 1156.2 11S7.1 1158.0 1158.8 1159.6 Internal Energy B.t.u. .... Evap. Steam' 1 or P Entropy Water . tsvap. Steam n or 6 L/-T or r,,.T Nor# 972.9 ' .956.7 946.4 938.6 932.4 1042.7 0.1327 1050.7 0.1749 10SS.8 0.2008 1059.5 . . .0.2198 1062.5 . 0.2348 1,8427 1.7431 1.6840 1.6416 1,6084 1.9754 1.9180 1.8848 1.8614 1.8432 Gauge Press lbs. 927.0 922.4 .918.2 914.4 910.9 1064.9 1067.1 1069.0 1070.5 1072.0 0.2471 0.2579 0.2673 0:2756 0.2832 1.5814 1.5S82 1.5380 1.5202 1.5042 1.828S 1.8161 1.8053 1.7958 1.7874 907.8 904.8 902.0 899.3 897.6 1073.4 1074.7 1075.8 1076.8 1077.5 0.2902 0.2967 . 0.3025 0.3081 0.3118 1.4895 1.4760 1.4639 1.4523 1.4447 1.7797 1.7727 1.7664 1.7604 1.7565 .0 896.8 894.4 892.1 889.9 887.8 1077.8 1J78.7 1079.6 1080.4 1081.1 0.3133 0.3183 0.3229 0,3273 0.33 IS 1.4416 1.4311 1.4215 1.4127 1.404S 1.7549 1.7494 1.7444 1.7400 1.7360 .3 1.3 2.3 3.3 4.3 885.8 663.9 882.0 880.2 878.5 1081.9 1082.6 1083.2 1083.9 1084.5 0.3355 0.3393 0.3430 0.3465 0.3499 1.3965 1.3887 1.3811 1.3739 1.3670 1.7320 1.7280 1.7241 1.7204 1.7169 5.3 63 7.3 8.3 9.3 ' 1 atmo (standard atmosphere) = 760 turns, of Hg. by def. = 29.921 ins. of Hg. = 14.696 lbs. per sq. in. T * =t` +459.6; J =777.S ft. lbs. per B.t.u. Hog = 2.89 071,; A = >/j = 1.286 XI0-1; 144 A =0.1852 (Jog =1.26 7641- NOTE.--The gauge pressures arc put in only for your guidance in making quick estimates of conditions, Wherever very accurate computations ure to be made, find out the atmospheric pressure at vour altitude and add this to the gauge pressure ond use the resulting abvu/ure pressure in the table. 249 CRMC-003613 Johns-Manville Service to Railroads Steam Table (Continued) Press. Vos. 10.3 11.3 J2.3 13.3 14.3 Temp. Press. Sp.Vol. Density cu. ft. lbs. per Heat of the Latent Total Internal Energy heat of heat of B.t.u. Entropy Gauge lbs. Deg. F Atmos* cu. ft liquid evap. steam Evap. Steam Water Evap. Steam Press P t ---* v or 5 W horq L or r H 1 or p E n or 0 L/T or r/T R Or lbs. 25 240.1 1.701 16.30 0.0614 208.4 9S2.0 1160.4 876.8 1085.1 0.3532 1.3604 3.7136 10.3 26 242.2 1.769 15 72 0.0636 210.6 950.6 1161.2 875.1 1085.6 0.3564 1.3542 1.7106 11.3 27 244.4 1.837 15.18 0.0659 212.7 949.2 1161.9 873.S 1086.2 0.3594 1.3483 1.7077 12 3 28 246.4 1.905 14.67 0.0682 214.8 947.8 1162.6 872.0 1086.7 0.3623 1.3425 1.7048 13.3 29 248.4 1.973 14.19 0.0705 216.8 946-4 1163.2 870.5 1087.2 0.3652 1.3367 1.7019 14.3 1S.3 36.3 17.3 18.3 19.3 30 250.3 2.041 13.74 0.0728 218.8 945.1 1163.9 869.0 1087.7 0.3680 1.3311 1.6991 1S.3 252.2 2.109 13.32 0.0751 220.7 943.8 1164.5 867.6 1088.2 Q.3707 1.3257 1,6964 16.3 32 254.1 2.178 12.93 0.0773 222.6 942.5 1165.1 866.2 1066.6 0.3733 1.3205 1.6938 17.3 33 255.8 2.246 12.57 0.0795 224.4 941.3 116S.7 864.8 1089.1 0.3759 1.3155 1.6914 18.3 34 257.6 2.314 12.22 0.0818 226.2 940.1 1166.3 863.4 1089.5 0.3784 1.3107 1.6891 19.3 20.3 21.3 22.3 23.3 24.3 35 259.3 2.382 11.89 0.0841 217.9 938.9 1166.6 862.1 1089.9 0.3808 1.3060 1.6868 20.3 36 261.0 2.450 11.58 0.0863 229.6 937.7 1167.3 860.8 1090.3 0.3832 1.3014 1.6846 21.3 262.6 2.518 11.29 0.0886 231.3 936.6 1167.8 859.S 1090.7 0.3855 1.2969 1.6824 22.3 38 264.2 2.S86 11.01 0.0908 232.9 935.5 1168.4 858.3 1091.0 0.3877 1.2925 1.6802 23.3 39 26S.8 2.6S4 10.74 0.0931 234.5 934.4 1168.9 857.1 1091.4 0.3899 1.2882 1.6781 24.3 25.3 26.3 29.3 40 267.3 2.722 10.49 0.0953 236.1 933.3 1169.4 855.9 1091.8 0.3920 1.2841 1.6761 25.3 41 268.7 2.790 10.2S 0.09*6 237.6 932.2 1169.8 854.7 1092.2 0.3941 1.2800 1.6741 26.3 270.2 2.858 10.02 0.0998 239.1 931.2 1170.3 853.6 1092.5 0.3962 1.2759 1.6721 27.3 271.7 2.926 9.80 0.1020 240.5 930.2 1170.7 852.4 1092.8 0.3982 1.2720 1.6702 28.3 44 273.1 2.994 9.59 0.1043 242.0 929.2 1171.2 851.3 1093.2 0.4002 1.2681 1.6683 29.3 30.3 31.3 32.1 33.3 34.3 45 274.5 3.062 9.39 0.1065 243.4 928.2 1171.6 850.3 1093.5 0.4021 1.2644 1.6665 30.3 46 27S.B 3.130 9.20 0.1087 244.8 927.2 1172.0 849.2 1093.8 0.4040 1.2607 1.6647 31.3 47 277.2 3.198 9.02 0.1109 246.1 926.3 1172.4 848.1 1094.1 0.4059 1.2S71 1.6630 32.3 48 278.5 3.266 8.84 0.1131 247.5 925.3 1172.8 847.1 1094.4 0.4077 1.2536 1.6613 33.3 49 279.8 3.334 8.67 0.1153 248.8 924.4 1173.2 846.1 1094.7 0.4095 1.2502 1.6597 34.3 35.3 . 36.3 . 37.3, . 38.3 39.3 50 . 51 52 53 54 281.0 282.3 283.5 284.7 . 285.9 3.402 3.470 3.538 3.606 3.674 8.51 8.35 8.20 8.05 . 7,91 0.1175 0.3197 0.1219 0.1241 ,0.1263 250.1 251.4 2S2.6 253.9 2S5.1 923.5 922.6 921.7 920.8 919.9 1173.6 1174.0 1174.3 1174.7 1175.0 843.0 844.0 843.1 842.1 841.1 . 1095.0 1095.3 5095.5 1095.8 1096.1 0.4113 0.4130 0.4147 0.4164 0.4180 1.2468 1.2435 1.2402 1.2370 1.2339 1.6581 3.6565 1.6549 1.6534 1.6519 35.3 36.3 37.3 38.3 39.3 40.3 4i.3 : 43.3 . 44.3 , 55 56 57. 58 S9. 287.1 . 288.2 289.4 290.5 291.6 ,3.742 3.810 3.878 3.947 4.015 7.78 7.65 .7:52 7.40 7.28 0.1285 0.1307 0.1329 0:i350 04372 256.3 257.5 2S8.7 259-8 261.0 919-0 916.2 917-4 916.5 915.7 1175.4 1175.7 1176:0 1176.4 1176.7 840.2 839.3 838.3 837.4 836.S 1096.3 1096.6 1096.8 1097.1 1097.3 0.4196 0.4212 0:4227 0.4242 0.4257 1.2309' 1.2278 ' 1.2248 1.2218 1.2189 1.6505 1.6490 1.6475 1.6460 1.6446 40.3 41.3 ' 42.3 43.3 44.3 45.3, 46.3 :. 49.3 .60 61 64 ; . .292,7 293.8 294.9 295.9 .2.97.0 4.083 4.151 4.219 4.287 ,4.355 .. 7.17 7.06 6:95 6:85 6.75 0.1394 0.1416 0.1438 ,0.1460 0.1482 262.1 263.2 264.3 265.4 .266.4 . 914.9 914.1 : 913.3 . 912.5 911.8 1177.0 1177.3 1177.6 1177.9 1178.2 835.6 834.8 833.9 833.1 832.2 1097.6 1097.8 IQ98.0 1098.2 1098.4 0.4272 0.4287 0.4302 0.4316 0.43,30 1.2160 1.2132 1.2104 1.2077 1.2050 1.6432 1.6419 1.6406 1.6393 .1.6380 4S.3 46.3 47.3 48.3 49.3 50.3 SI.3 ' 52.3.' S3.3 i. 54.3 6S 66- : 67 68 69 ;29fl.0,. i299.Q\ .300:0 ::3'oi;o 302-0. ,4.423 4.491 4.S59 . 4i627 .4,695 6.65 0..1S03 ,6.56 0.1525 6.47 . 0.1547 648 0.1569 6129 O.I590 . .267.5 268.5 ,269.6 270.6 ,271.6 911.0 . 1178.5 . 910.2 .1)78.8 ; 909.5 1179.0 908.7 1179.3 908.0 1179.6 831.4 830:5 829.7 828.9 828.1 1098.7 1098.9'. 1099.1 1099.3 1099.5 : 0.4344 0.4358 0.4371 0.4385 0.4398 1.2024 ' 1.6368 1.1998 . 1.6345 . L1972 1.6323 1.1946 1,6311 1.1921 . 1.631.9 . 50.3 51.3 52.3 53.3 54.3 55.3 ' 59,3 '. 70 74. -. 302.9 .4.763 " 303.9 4:831 304.8 -4:899 .305.8. .4.967 - 306.7 ' 5.035 6.20 ' 6.12 : "6.04 5.96 i 5.89 0,1612 0.1634 Q.16S6 ,0.1678 0.1699 .2,72.6 ,273.6 .274.5 275.S 276.5 907.2 906.5 . 90S-8 90S! 904.4 ,11.79.8 1180.1 1180.4 1180.6 1180.9 827.3.826.5 825.8 825:0 . 824.2 1099.7 0.4411 1099.9 0.4424 1100.1 0.4437 1100.3 0.4449 1100.5 . 0.4462 1.1896L1872. 1.1848 1.182S 1.1801 1.6307. 1.6296 1.6285 1.6274 1.6263 S5.3 56.3 57.3 58.3 S9.3 60.3 61.3 64.3 ,76. ' .78 . 79 .'307.6 308,5 309-4 310.3 311.2 5.103 5.171 5:239 5.307 5.375 5.81 ' -5.74 ' 5.67 5.60 5.54 0.1721 0.1743 0:i764 0.1786 0.1808 277.4 .278.3 ,279.3 , 280.2 281.1 . 903.7 903-0 902.3 901.7 901.0 1181.1 1181.4 1181.6 1181.8 1182.1 823.5 822.7 822.0 821.3 820.6 1100:6 1100.8 1101.0 1101.2 1101.4 0.44 74 - 0.448/ 0.4499 0.4S11 0.4523 1.1778 1.1755 1.1732 1.1710 1.1687 1.6252 1.6242 1.6231 1.6221 1.6210 60.3 61.3 62.3 63.3 64.3 65.3 66.3 67.3 68.3 69.3 , 80 312.0 5.444 S.47 0.1829 282.0 900.3 1182.3 819.8 1101.6 0.4535 1.1665 1.6200 65.3 81 ,312.9 5.S12 ,5.41 0.1851 282.9 899.7 1182.5 819.1 \ 101.7 0.4546 1.1644 1.6190 .82 313.8 5.580 5.34 0.1873 283.8 899.0 1182.8 818.4 1101.9 0.4557 1.1623 1.6180 67.3 83 314.6 5.648 5.28 0.1894 284.6 898.4 1183.0 817.7 1102.1 0.4568 1.1602 1.6170 68.3 84 315.4 ,5.716 5.22 0.1915 285.5 897.7 1183.2 857.0 1102.2 0.4579 1.1581 1.6160 69.3 70.3 65 3V6.3 5.784 S.16 0.1937 286.3 897.1 1183.4 816.3 1102.4 0.4590 1.1561 1.6151 70.3 71.3 . 86 317.1 5.852 5.10 0.1959 287.2 896.4 1183.6 815.6 1102.6 0.4601 1.1S40 1.6141 71.3 72.3 87 317.9 5-920 5.05 0.1980 288.0 895.8 1183.8 815.0 1102.7 0.4612 1.1520 1.6132 72.3 73.3 88 318.7 5.988 5.00 0.2001 288.9 . 895.2 1184.0 814.3 1102.9 0.4623 1.1500 1.6123 73.3 74.3 89 319.5 6.056 4.94 0.2023 289.7 894.6 1184.2 613.6 1103.0 0.4633 1.1481 1.6114 74.3 7S.3 76.3 77.3 78.3 79.3 90 320.3 6.124 4.89 0.2044 290.5 893.9 1184.4 813-0 1103.2 0.4644 1.1461 1.610S 7S.3 91 321.1 6.192 4.84 0.2065 291.3 893.3 1184.6 812.3 1103.3 0.4654 1.1442 1.6096 92 321.8 6.260 4.79 0.2087 292.1 892.7 1184.8 811.7 1103.5 0.4664 1.1423 1.6087 93 322.6 6.328 4.74 0.2109 292.9 892.1 1185.0 8)1.0 1103.6 0.4674 1.1404 1.6078 94 323.4 6.396 4.69 0.2130 293.7 891.5 1185.2 810.4 1103.8 0.4684 1.1385 1.6069 80.3 81.3 82.3 83.3 84.3 9S 324.1 6.464 4.65 0.2151 294.5 890.9 1185.4 809.7 1103.9 0.4694 1.1367 1.6061 80.3 96 324.9 6.532 4.60 0.2172 295.3 890.3 1185.6 809.1 1104.1 0.4704 1.1348 1.6052 97 325.6 6.600 4.56 0.2193 296.1 889.7 1185.8 808.5 1104.2 0.4714 1.1330 1.6044 82.3 98 326.4 6.668 4.51 0.221S 296.8 889.2 1186.0 807.9 1104.4 0.4724 1.1312 1.6036 83.3 99 327.1 6.736 4.47 0.2237 297.6 886.6 1186.2 807.2 1104.S 0.4733 1.1295 1.6028 84.3 1 atmo {standard atmosphere) = 760 mmt. of He. by def. = 19.971 ins. of Kg.13 14.696 lbs. per sq. in, T* = t * + 459.6; J =777.5 ft. lbs. per B.t.u. (log = 2.89 0711; A = /j =1.286 X10-1; 144 A =0.18S2 (log = 1.26 664[. NOTE.--The gauge pressures are put in only for your guidance in making quick estimates of conditions. Wherever very accurate com putations are to be made, find out the atmospheric pressure at your Altitude and add this to the gauge pressure and use the resulting ab$olu to pressure ia the table. 250 CRMC-003614 Johns-Manville Service to Railroads Steam Table (Continued) Gauge Press. Absol. Press. lbs. 89.3 104 94.3 109 99.3 114 106.3 114.3 123 129 124.3 139 134.3 149 144.3' ' 159 148,3; 154.3 169 164.3 179 174.3 184.3 189 191' 199 Temp. Press. Deg. F, Atmos* 330.7 7.08 334.1 7.42 337.4 7.76 343.2 8.37 346.8 8.78 ' 352.S 9.46 3S7.9 : ,'359;0 10.14 363.1 10.82 36e:o ' . 11.50'- -372.7 ,.12:i8 377.2 381:4 12.86 . 13.00 13:40 13.54 Sp.Vol Density cu. ft. lbs. per per lb. cu. ft v or s i/v 4.268 0.2343 Heat of the liquid h or q 298.3 299.1 299.8 300.6 301.3 Latent heat of evap. L or r 886.0 887.4 866.9 886.3 885.8 Total steam H 1166.3 1186.5 1186.7 1186.9 1187.0 Internal Energy Evap. 1 or P 606.6 806.0 805.4 804.8 804.2 Steam E 1104.6 1104.8 1104.9 1105.0 1105.1 Entropy Water Evap. Steam n or 6 L, T or r/T Nor* 0.4743 1.1277 1.6020 Gauge Press lbs. 85.3 86.3 0.2386 4.082 0.2450 302.0 302.7 303.4 304.1 304.8 885.2 884.7 884.1 883.6 883.0 1187.2 1187.4 1187.5 1187.7 1187.9 803.6 803.0 802.5 801.9 801.3 1105.3 110S.4 0.4789 0.4798 1.1191 1.5980 90.3 3.912 0.2556 30S.S 306.2 306.9 307.6 308.3 882.5 881.9 881.4 880.9 880.4 1188.0 1188.2 1188.4 1188.5 1188.7 800.7 800.2 799.6 799.0 798.S 1105.9 1106.0 1106.2 1106.3 1106.4 0.4834 1.1108 1.5942 0.4860 9S.3 3.639 0.7480 3.478 0.2875 309.0 310.3 311.6 313.0 314.3 315.5 316.6 318.0 879.8 878.8 877.8 876.7 87S.7 874.7 873.8 872.8 1188.8 1189.1 1189.4 1189.7 1190.0 1190.3 1190.S 1190.8 797.9 796.8 795.7 794.7 793.6 792.6 791.5 790.S 1106.5 1106.8 1107.0 1110.2 1107.4 1107.7 1107.9 1108.1 0.4877 0.4894 1.1030 1.5907 100.3 0.4959 0.4974 1.0880 1.5839 110.3 3.241 0.3086 319.3 320.5 321.7 322.8 324.0 871.8 870.9 869.9 . 869.0 868.1 1191.1 1191.3 1191.6 1191.8 1192.1 789-S 788.5 787.5 786.S . 785.5 1108.3 1108.5 1108.7 1108.9 1109.1 O.SOOS 1-0796 1.5801 116.3 3.033 0:3129 0,3171 0:3213 0:32SS 0:3297 325.2 326.3 327.4 328.6 -329.7 867.2 866.3 865.4 864.5 863.6 1192.3 1192.6 1192.8 1193.0 1193.3 784.6 783.6 782.7 781:7 780.8 1109.3 1109.5 1109.6 0.5079 1.0662 1.5741 126.3 2.861 0.3508 330.8 331.9 ' 332.9 334.0 33S.1 862.7 861.8 861.0 860.1 859.3 1193.5 1193.7 1194.0 1194.2 1194.4 779.9 779.0 778.1 777.2 776.3 1110.2 1110.4 1110.S 1110.7 1110.8 0.5148 0.5162 . 0.5175 0.5188 0.5201 1.0538 1.0513 1:0489 .1.0443 1.5686 136.3 336.2 - 337.2 ' 338.2 0,3675 339.2 > 2.690 0.3717 : 340.2 8S8.4 8S7.6 6S6.8 8S5.9 855.1 . 1194.6 1194.8 1195.0 1195.2 : 1195.4 775.4 774.S. 773.6 . 772.8 771.9 1111.0 1111.2 > 1111.3 . 1111.4 . 1111.6 0.5214 v 0.5226 . 0^5239 0.5251 0.5263, 1.0420 -1,0398 1.0354 1.0332 1.5634 146.3 15,4.3 2.602 . 2.547 0.3759 ; 341.2 0:3801. ' -342.2 '0.-3843 . 343.2 0.-3865 1 344.2 0:3927 '345.2 854.3 853.S 852.7 851.9 8S1.2 : 1195.5 771.1 1111.7 1195.7 . 770.2 . 1111.9 , 1195.9 .7.69.4 . 1112.0 1196.1 768.6 . 1112.2 : 1196-3. : 767.8 1112.4 , 0.5275 1.0311 . 0.5287 . 1,0289 0.5299 0.5311 - 1.0246 .0-.5322 1.0225 1.S586 156.3 1.5567. , 160.3 162.3 1.5547 -164.3 2.520 2.418 0.3969 0:4010 0:4052 '0.4094 0.4136 - 346.1 347.1 ' 348.0 1 349.0 .349.9 850.4 849.6 848.8 848.0 .847.3 1196.5 767.0 1196.7 766.2 1196.8 765-4 1197.0 764.6 ' 1197.2 . 763.8 1112.5 1112.6 lli2.8 1112.9 1113.0 0.5334 1.0205 ' 0.5345 . .1.0185 0.S356 1-.0164 .0.5367 1.0144 0.5378 ' 1.0124 1.5539 1.5530 1.5520 1.5511 1.5502 166.3 '168.3 170.3 . 172.3 174.3 2.393 2.369 2.346 2.323 2.301 0.4178 0.4220 0.4262 0.4304 0.4346 350.8 351.7 352.7 353.6 ' 354.4 846.5 845.8 845.0 844.3 843.6 1197.3 1197.S 1197.7 1197.8 ' 1198.0 763.0 762.2 761.4 760.7 759.9 1113.2 1113.3 1113.4 1113.6 1113.7 0.S389 0.5400 . 0.5410 0.5421 0.5431 1.010S 1.0085 . 1.0066 1.0047 1.0029 1.S494 1.5476 1.5468 1.5460 176.3 184.3 194.3 201 203 205 384.0 207 384.8 14.08 209 385.6 14.22 2.279 2.2S8 2.237 2.217 2.197 0.439 0.443 0.447 0.4S1 0.4SS 355.3 356.2 357.1 358.0 358.8 842.8 842.1 841.4 840.6 639.9 1198.2 1198.3 1198.S 1198.6 1198.8 759.2 758.4 7S7.6 7S6.9 756.2 1113.8 1113.9 1114.0 1114.2 1114.3 0.5442 0.5452 O.S463 0.5473 0.5483 1.0010 0.9992 0.9973 0.99S5 0.9937 1.5452 1.5444 1.S436 1.S428 1.5420 186.3 188.3 190.3 192.3 194.3 196.3 198.3 200.3 204.3 208.3 210.3 212.3 214.3 211 386.4 14.36 213 387.2 14.49 215 388.0 14:63 217 388.8 14.77 219 389.S 14.90 221 390.3 15.04 223 391.1 15.17 225 391.9 1S.31 227 392.6 15.45 229 393.4 IS.56 2.177 2.158 2.138 2.118 2.100 0.459 0.463 0.468 0.472 0.476 2.082 2.064 2.046 2.030 2.013 0.480 0.485 0.489 0.493 0.497 3S9.6 360.5 361.4 362.2 363.0 363.8 364.6 365.5 366.3 367.1 839.3 838.6 837.9 837.2 836.5 835.8 835.1 834.4 833.8 833.1 1198.9 1199.1 1199.2 1199.4 1199.5 1199-6 1199.8 1199.9 1200.0 1200.2 75S.S 754.7 754.0 753.3 752.6 751.9 751.2 750.5 749.8 749.1 1114.4 1114.5 1114.6 1114.7 1114.8 111S.0 1115.1 1115-2 1115.3 1115.4 0.5493 0.5503 0.5513 0.SS23 0.5533 0.S543 0.5553 0.5562 0.5572 0.5582 0.9920 0.9902 0.988S 0.9867 0.9850 0.9833 0.9816 0.9799 0.9783 0.9766 1.5413 1.540S 1.5398 1.5390 1.5383 1.5376 1.S369 1.5361 1.S3S5 1.5348 196.3 198.3 200.3 202.3 204.3 206.3 208.3 210.3 212.3 214.3 *1 atmo (standard atmosphere) =760 mms. of He- by definition =29-921 ins. of Hg. = 14.696 lbs. per sq. in. T" =t *+459.6; J =777.5 ft. lbs. per B.t.u. [log =2.89 071J: A ='/j =1.286 X10-J; 144 A =0.1852 Jlog =1.26 664). NOTE.---The gauge pressures are put in only for your guidance in making quick estimates of conditions. Wherever very accurate com putations are to be made, find out the atmospheric pressure at your altitude and add this to the gauge pressure and use the resulting absolute pressure in the table. 251 CRMC-003615 Johns-Manville Service to Railroads Steam Table --(Continued) Gauge Preia. lb*. 216.3 218.3 120.3 222.3 224.3 Absol. Press. lbs. x> 231 233 235 237 239 Temp. Deg. P. t 394.1 394.9 395.6 396.4 397.1 Press. Atmos* ---* 35.72 15.86 15.99 16.13 16.26 Sp.Vol. cu. ft. per lb. v or s 1.996 1.980 1.964 1.948 1.932 Density lbs. per cu. ft */v 0.501 0.505 0.509 0.513 0.518 Heat of the liquid h orq 367.9 368.7 369.4 370.2 371.0 Latent heat of evap. L or r 832.4 831.8 831.1 830.4 829.8 Total heat of steam H 1200.3 1200.4 1200.6 1200.7 1200.8 Internal Energy B.t.u. Evap. Steam 1 or p E 748.4 747.7 747.0 746.4 745.7 1115.5 1115.6 1115.7 1115.8 1115.9 Entropy Water Evap. Steam no r 0 L/Tort/T Note O.S591 0.S6C1 0.5610 Q.S619 0.5629 0.9750 0.9733 0.9717 0.9*00 0.9684 1.5341 1.5334 1.5327 1.5319 1.5313 Gauge Press lbs. 216.3 218.3 220.3 221.3 224.3 226.3 228.3 230.3 232.3 234.3 241 397.8 16.40 243 398.5 16.53 245 399.3 16.67 247 400.0 16.81 249 400.7 16.94 1.917 1.902 1.887 1.872 1.857 0.522 0.526 0.530 0.534 0.538 371.8 372.6 373.3 374.1 374.8 829.2 828.5 827.9 .827.2 826.6 1200.9 1201.1 1201.2 1201.3 1201.4 74S.0 744.4 743.7 743.0 742.4 1116.0 1116.1 1116.2 1116.3 1116.4 0.5638 0.5647 0.5655 0.5663 0.5672 0.9668 0.96S3 0.9638 0.9623 0.9607 1.5306 1.5300 1.5293 1.5286 1.5279 226.3 228.3 2303 23 2J 234.3 235.3 250 401.1 17.01 237.3 252 401.8 17.15 239.3 254 402.4 17.28 241.3 256 403.1 17.42 243.3 258 403.8 17.56 1.850 1.836 1.822 1.839 1.795 0.541 0.545 0.549 0.553 0.557 375.2 376.0 376.7 377.5 378.2 826.3 82S.6 825.0 824.4 823.7 1201.5 1201.6 1201.7 1201.8 1201.9 742.0 741.4 740.8 740.1 739.5 1116.4 1116.5 1116.6 1116.7 1116.8 0.5676 0.5685 0.5694 0.5702 0.5711 0.9600 0.9584 0.9569 0.95S4 0.9539 1.5276 1.5269 1.5263 1.5256 1.5250 235.3 237.3 239.3 241.3 243.3 245.3 247.3 249.3 2S1.3 253.3 260 404.5 17.69 262 405.2 17.83 264 405,9 17.96 266 406.6 18.10 268 407.2 18.24 1.782 1.769 1.756 1.743 1.731 0.561 0.565 0.S69 0.574 0,578 378.9 379.6 380.4 381.1 381.6 823.1 822.5 821.9 821.3 820.7 1202.1 1202.2 1202.3 1202.4 1202.S 738.9 738.2 737.6 737.0 736.4 1116.9 1117.0 1117.1 1117.2 1117.2 0.5719 0.5727 0.5735 0.5744 0.5752 0-9525 0.9511 0.9497 0.9482 0.9468 1.5244 1.5238 1.5232 1.5226 1.S220 245.3 247.3 249.3 251.3 253.3 255.3 270 407.9 18.37 257.3 272 408.6 18.SI 259.3 274 409.2 18.64 261.3 276 409.9 18.78 263.3 278 410.5 18.92 1.718 1.705 1.693 1.681 1.669 0.582 0,587 0.591 O.S95 0.599 382.5 383.2 383.9 334.6 385.3 820.1 819.5 816.9 818.3 817.7 1202.6 1202.7 1202.8 1202.9 1203.0 735.8 735.1 734.5 733.9 733.3 1117.3 1117.4 1117.S 1117.6 1117.6 0.5760 0.5768 0.5776 0,5784 0.5792 0.9454 0.9440 0.9426 0-9412 0.9398 1.5214 1.5 208 1,5202 1.5196 1.5190 255.3 257.3 2S4.3 261.3 263.3 365.3 267.3 269.3 271.3 273.3 280 282 284 286 288 411.2 411.8 412.4 413.1 413.7 19.05 19.19 19.32 19.46 19.60 1.658 1.646 1.635 1.624 1.613 0.603 0.608 0.612 0.616 0.620 386.0 386.7 387.4 388.1 388.7 817.1 816.5 815.9 815.4 814.8 1203.1 1203.2 1203.3 1203.4 1203.5 732.7 732.1 731.5 730.9 730.3 1117.7 1117.8 1117.9 1118.0 1118.1 0.5800 0.58QS 0.5816 0.S824 0.5832 0.9385 0.9371 0 9357 0.9344 0.9330 1.5185 1.51*9 1.5173 1.5168 1.5162 265.3 267.3 269.3 271.3 273.3 275.3 277.3 279.3 281.3 , 283.3 290 292 294 296 298 . 414.4415.0 4IS.6 416.2. - 416.8 19.73 19.87 30.01 20.14 20.28 1/602 1.591 1.581 1.571 1.561 0.624 0.629 0.633 0.637 0.641 . 389.4 390.1 390,8 391.4 392.1 814.2 813.6 812.5 811.9 1203.6 1203.7 1203.8 1204.0 729.7 729.2 728.6 728-0 .. 727.4 1118.1 1118.2 1118.3 1118.4 1118.4 - 0.S840 0.5848 0.5856 0.5863 0.S871 0.9316 0.9302 0.9289 0.9276 0.9263 1.5156 1.5150 1.5143 1.5139 1.5134 275.3 277.3 279.3 281.3 283.3 285.3 295.3 .305.3 " 3SS.3. 375.3--. 300 310 320 370 390 . ` 417.5 420.5 423.4 - 437.2 ; 442.3- . 20.41 21.09 21.78 25.18 26.54 ' 1.S51 1.S02 1.456 . 1.264 1.200 0.645 0.666 0.687 0.791 0.833 392.7 811.3 1204.1 395.9. 1204.S 399.V 1204.9 4J4.0 . , 792:8. - . 1206.8 419.5 , 787.9 1207.4 . 726.8 *24.0 721.2 708-2 . 703-3 .. 1118.5 1118.9 1119.21120.8 1121.4 0.5878 0.5915 0.59S1 0.6116 0.6178 0.9251 0.9187 0.9125 0.8S40 0.8737 1.5129 1.5102 1.5076 1.4956 1.4915 , 285.3 295.3 305.3 355.3 375.2 385.3 405.3-- 455.3- .S10.3 . . 560.3". S8S.3V- 400 420 470 525 575 600 444.7 .449.6 460.9 472.3 -.481.9 486.4 . 27.22 28.58 31.98 3,5.72 39.13: 40.83 1.17 .1.11 -0=99 0.89 0.81 0.78 0.86. 0.90 1.01 1.12 . 1.24" 1.28 422. 427. 440., 453. : 464. - 469. 1 786. 780. ' 769. 747. 742. 1208. 1208. 1209. 1210.. 1211. 1211. 701. 696. 685. 673. 663. 658. ' 1122. . 1122. 1123. 1124. 1125. 1125. , , . 0.621 0.627 . 0.640-' 0.654 ; 0.664 0.670 0.868 0.858 0:835 0.813 0.794 0.784 1.489 1.485 1.475 1.467 1.458 1.454 385-3 405.3 455.3 510.3 560.3 585.3 *i atmo (standard atmosphere} = 760 Hg. by definition.=29 921 ins. of Hg. =14.696 IBs; per sq. in. 1 . , T-? =.t *rf4S9.6;. J;= 777.5 ft. lbs. per B.t.u. [log =2.89 071J; A = '/j - 1.286X1.0-3: 144 A =0.1852 (log =1.25 764J. . NOTE.---The gauge pressures are put in only for youc guidance in malting quick estimates of conditions. Wherever very accurate ccm- putalipns.are to be made, find, out the atmospheric pressure-at your alti: ude and add this to the gauge pressure and use: the resulting, absolute pressure in:the table., . .' Table showing Loss due to Steam-leakage SIZE OF .AIR; -;;r;| :........ ! STEAM ' - WATER. OPENING Number of Cu. Ft. - Total Cost of Number of'Pounds ' Total Cost of Number: of Gals.' Total Cost of -Wasted/, p,er; Mo. Waste per Mo. Wasted per Mo. Waste per Mo.- .-Wasted.per Mo. Waste per Mo. @ 100 lbs. -Pressure 10c. per M. Cu. Ft. 100 lbs. Pressure @ 60c. per M. lbs. 40 lbs. Pressure 15; 3c. per N3. Gals. 17,798,400 $1,779.84 305,000 $483.00 . . 1,231,000. 1' ' i $192.00 V 9,979,200 997.92 460,000 276.00 692,400 108.00 V 4,449,600 444.96 303,000 121.80 307,700 ' 48.00 'w* 1,114,560 278,640 111.46 27.86 50,500 12,750 30.30 7.65 76,900 19,200 | 12.00 3.00 69,552 6.96 3.175 1.91 4,800 .80 This Table was prepared hy the Rock Island Railroad ami y.>t:'d on their bulletin boards. This Table has n direct applicaticn to Steam Traps, Piston and Plunder Packings and Sheet Pac!ii:)c. . .v.-.s.-Manville Traps do not air bind. The pet cock with which they are furnished docs not have to be "cracked " to allow air t,- off and keep the (rap functioning properly. The quantity of steam which is lost through open steam pet cocks is convinciu^A -..c*\vt\ in the chart. As regards Packings, the chatt i? cl assistance in show.ng bow necessary it is to maintain packing boxes and tia.-;;.-.- in steam lines in a proper state of tightness. CRMC-003616 Johns-Mairville Service to Railroads Volume of Water at Various Pressures At Saturation Temperatures Corresponding to Pressures Given. Gauge Pressure, Lbs. Per Sq. In. .3 25.3 50.3 75.3 100.3 125.3 150.3 175.3 200.3 225.3 265.3 435.3 Absolute Pressure, Lbs. Per Sq. In. 15 40 65 90 US 140 165 190 215 240 280 450 Specific Volume, V' or O Cu. Ft. Per Lb. 0.0167 0.0171 0.0174 0.0176 0.0178 0.0180 0.0182 0.0184 0.0185 0.0186 0.0189 0.0197 Density, v, Lbs. Per Cu. Ft. Energy of Expansion, 144 Ap V' B. t. u. 59.8 58.3 57.4 56.8 56.0 55.4 54.9 54.5 54.0 53.6 53.0 50.8 0.05 0.13 0.21 0.30 0.38 0.47 0.56 0.65 0.74 0.83 0.98 1.65 Heat Losses from Uninsulated Hot Surfaces Steam Pressure (Gauge) 0 10 25 50- 75 100 150 200 250 Steam Temperature (Deg. Fahr.) 212 240 267 298. 320 338 366 . 388 406 : ORDINARY STEAM TEMPERATURES Temperature of Surrounding Air 70 F. Difference between Temper- Loss Per Sa. Ft. ature of Steam and Sur- Per Hour rounding Air (Deg. Fahr.) (B.t.u.) 142 170 197 228 250 . 268 296 318, 336.7 334 425 522.5 644 , 737.5 820 . 950 1,079 1,184 . Per Year 293 372 458 564 646 7187 840 945 . 1,036 . Number of Sq. Ft. of Surface That Wastes a Ton of Coal in 1 Year 6.82 5.38 4.37 3.55 3.10 2.79 2.38 2.12 1.93 Surface Temperature-' (Deg. -Fahr;) lOOr : 120 - .1.40-7. .. - 160: . 180 - ; 20.0.7- TEMPERATURES LOWER THAN 212 DEG. Difference .Between Surface Temperature and Surrounding. Air. (Deg. Fahr.) Loss Per Sa. Ft. : Per Hour (B.t.u.) F.' ' 7 Waste of Coal in Lbs; Per Sq. Ft. ' Per Year - 30 50.' 7 70: . 90- - . 110 7 . 130- .... : 56.6: 97.5 ' 142. 190. 242. .298.5 . 49.6 "7 '85.4 ... 124-3 ------ - 166.3- 212. 261.5. - Number of Sq. Ft. of Surface That Wastes a Ton of Coal in 1 Year 40.3 23.4 16.1 . 12.03 9.44 7.65 .Above figures .involving. waste-.of coal are .based-on 10.00.0 B. t.u. available per pound of coil, 'which is'equivalent to a boiler efficiency of 70% usipg.coal with'an assumed heat value of about 14,000 B. t. q. per pound.1 ' ." ......... - These figures are very, conservative.-as both the1 boiler efficiency and the heat value of the coal are high--a lesser boiler efficiency or inferior grade of coal would cause, even a greater waste in pounds of fuel. .. ' : .The figures are based-also-on .continuous service. 24 .hours per day. '. Minimum Thicknesses, of Steam Pipe Insulation to be used for Given Character of Service Steom;.r Pressures .. . Steam . Temperatures Thickness of Insulation for Pipes Larger than 4" in Size Thickness of Insulation Thickness of Insulation for Pipes 2'' to 4" in for Pipes jj" to 1 ;<" Size 0 to 25 lbs. 212 to 267 F. 1" or Standard* 1" or Standard* 1" or Standard* 25 to 100 lbs. 100 to 200 lbs. Higher Pressures { or Superheat ) 267 to 338 F. 338 to 388 F. \ 388 to 500 F. ] 500 to 600 F. lK" IK" 1" or Standard* 2" or D'ble Standard* IK" 1" or Standard * 214" 3" 2" or D'ble Standard* IK" 2K" 2" or D'ble Standard* For higher temperatures obtain special recommendations. * Standard and Double Standard thickness apply to 85 <1 Magnesia Insulation only--other thicknesses apply to all types of insulation. It is always preferable to apply insulation greater than 1^-inch thickness in two or more layers with all joints broken or staggered. 253 CRMC-003617 Nom inal Internal, , In. A ctual E xternal, In. J Approx. Internal, In . J Nom inal Thickness, External, In . 1 1 Internal, In. External, Sq. In . j Internal, Sq. In. 1 M e ta l, Sq. In . External Surface, F t. Internal S u rfa c e , F t. Length o f Pipe Con taining 1 Cu. F t., F t. N om inal W eight per F t., Lbs. No. of Threads per.In. o f Screw Area E xternal Surface per Lineal Foot, Sq. F t Data on. Standard Full-Weight Wrought-Iron and Steel Pipe Diameter c Transverse Areas Circum ference Length of Pipe per Sq.Ft. of X 0.405 K 0.540 X 0.675 K 0.840 X 1.050 0.27 0.36 0.49 0.62 0:82 0.068 0.083 0.091 0.109 0.113 1.27 1.70 2.12 2.63 3.30 0.85 1.14 1.55 1.95 2.59 0.13 0.23 0.36 0.55 0.87 0.06 0.10 0.19 0.30 0.53 0.07 0.12 0.17 0.25 0.33 ,9.44 14.15 7.08 10.49 5.66 7.76 4.55 6.15 3.64 . 4.64 2513.00 1383.30 751.20 472.40 270.00 0.24 27 .106 0.42 18 .141 0.57 18 .177 0.85 14 .220 1.13 14 .275 i 1.315 IK 1.660 IK 1.900 2 2.375 2K 2.875 1.05 1.38 1.61 2.07 2.47 0.134 0.140 0.145 0.154 0.204 4.13 5.22 5.97 7.46 9.03 3.29 4.34 5.06 6.49 7.75 1.36 2.16 2.84 4.43 6.49 0.86 1.50 2.04 3.36 4.78 0.50 0.67 0.80 1.07 1.71 2.90 2.30 2.01 1.61 1.33 3.65 2.77 2.37 1.85 1.55 166.90 96.25 70.66 42.91 30.10 1.68 2.27 2.72 3.65 5.79 UK -344 UK -435 UK -498 UK -622 8 .753 3 3.500 3K ' 4.000 4 4.500 ' 4K 5.0005 5.563 3.07 3.55 4.03 4.51 5.05- 0.2l7 11.00 9.63 0.226 . 12.57 11.15 ,0.237- '14.14 12.65 0.246 . ' 15.71 - 14.160.259 17.48 15.85 9.62 12.57 15.90 19.64 24.31 7.39 9.89 12.73 15.96 19.99 2.24 2.68 3.18 3.68 4.32 1.09 0.96 0.85 0.76 0.69 1.25 1.08 0.95 0.85 0.76 19.50 14.57 11.31: 9.02 7.20 7.57 9.11 10.79 12.54 14.62 8 .917 8 1.047 8 1.178 8 1.309 81.456 6 6.625 7 7.625 8 8.625 8 '8.6259 ' 9.625' 6.07' 7.02: 8.07 7.98 8.94' 0.280-: 0.301 0.276 ' 0.322 0.344 20.81 19.05 23.96 22.06 27.10 ''25.35" 27.10 25.07' 30.24 28.08 34.47' 45.66 58.43 -58.43 72.76 28.89 38.74 .51.15 5Q.02 62.72 5.59 6.92 7.28 8.41 10.04 0.58 0.50 0.44 0.44. 0.40 0.63 0.54 0.47 0.48 0.43 4.98 18,97 3.72 23.54. 2.82' 24.69 2.88 , 28:55. 2.29 33.91 8 1.734 8 1.996 8 2.257 8 2,257 8 2.519 10 10.750 . : 10.19' ; .0,278 ,,33.77 32.01 10 : 10.750 10.14- ..P-306, 33.77: 31.86 -10 10.750 10:02- 0.366 33.77 3.1.47' 11 ' 11.750- 11.00 0.375 36.91 34.56 12 12.750 12.09 0.328 40.06 ; 37.98' . 90.76 -90.76 '90.76 108.43 127.68 81.55 80.75 78.82 95.03 114.80 9.21 10.0.1 11,94 13.40 12.88 0.36 0.36 0.36 0.33 0.30 0.37 0.38 .. 0.38 , 0.35 0.32 ,1.76' ,,31.20 1.78 '34.24' 1.82 40.48 1.S1 45.56 1:25 . 43.77' 8 2.817 8 2.817 8 2.817 8 3.073 8 3.337 12 12.750 140D 14.000 150D 15.000 160D 16.000 12.00 13.25 14.25 15.25 0.375' 0.375 0.375 0.375 40.06 37.70 43.96 . 41.60 47.10 44.70' 50.27 47.90 127.68 153.86 176.62 200.96 113.10 137.81 159.39 182.55 14.59 16.05 17.23 18.41 0.30 0.27 0.25 0.24 0.32 0.29 0.27 0.25 - 1.27 1.04 0.90 0.75 49. S6 54.57 58.57 62.58 8 3.338 8 3.663 8 3.927 8 4.188 i i 254 CRMC-003618 Johns-Manville Service to Railroads Total Radiation Areas and Equivalents of Standard Flanged Fittings Including the accompanying flanges bolted to the fitting Figures in columns under "Area' give surface areas in SQUARE FEET. Figures in columns under "Pipe Lengths" give the number of feet of pipe which has an area equivalent to the area of the fittings. Size I. D. 1" I1HH"" 2V2" 3 3M 4 411" 5" 6" r 9" 10" 12" iV'O.D, 15" O.D. .. 16" O.D, Flanged Coupling Area Pipe Lengths .320 .533 .477 .93 ss 95 .672 S41 .945 1.06 1.12 1.03 1.122 1.344 1.474 1.07 1.14 1.13 1.622 1.82 2.17 1.11 1.049 1.097 2.41 3.00 . 3.43 .4.41 1.067 1.19 1.22 1.32 5.39 . 6, IS 6.6<J V .465 . 1.572 K60 90 Ell Area Pipe Lengths 795 .957 1.174 2.31 2.20 2.35 1.6S 2.09 2.38 2.65 2.78 2.60 2.98 3.53 3.95 4.44 5.13 6.17 2.85 2.90 3.01 3.049 2.95 3.09 6.98 8.71 10.18 13.08 3.09 3.457 3.61 3.92 16.38 38.50 20.17 4.47 4.72 4.82 Long Radius Ell Area Pipe Lengths .892 1.0S4 1.337 2.59 2.49 2.68 1.84 2.32 2.68 2.96 3.08 2.93 3.28 3.96 4.43 3.13 3.36 3.38 5.00 5.99 7.3S 3.43 3.45 3.697 8.56 10.57 12.3S 16.35 3.79 4.20 4.38 4.90 20:17 22.92 25.41 5.47 5.83 6 07 Tee Area 1 .235 1.481 1.815 Pipe Lengths 3.59 3.40 3.64 Cross Area. Pipe Lengths 1.622 1.943 2.38 4.72 4.47 4.78 2.54 3.21 3.66 4.08 4.26 3.99 3.32 4.19 4.77 5.34 5.56 5.70 4.48 5.41 6.07 4.28 4.59 4.63 5.83 7.03 7.87 5.56 5.97 6.01 6.81 7.84 9.37 4.67 4.53 4.69 8.82 10.08 12.00 6.06 5.81 6.01 10.55 13.18 15.41 19.67 4.67 5.23 4.47 5.59 . 13.44 16.78 19.58 24.87 5.96 6.66 6.95 7.45 24.81 27,91 30.32 6.78 '31.48 7.10 35.48 . 7.23 38.34 8.60 9.04 9.15 "otal Rad iation Areas a nd "Squrtalent s of Extra Heavy Flanged Fittings . Including, the accompanying flanges bolted to the fittincr Figures, in columns under "Area' giye surface areas in SQUARE FEET. :. Figures in columns under "Pipe Lengths" give the number of feet of pipe ,. 'which has an area equivalent to the area of the fittings.' Size I. D1 1" i Yi' 1" 2w y y/2 4" 412" 5" 6' ?'J 8" 9" 10" 12" 14" O.D. 15" O.D. 16" O.D. Flanged. Coupling ' .... - Pipe . Area Lengths 1. . 43S .510 .727 ' 1.273 1.172 1.459 ' \S4S 1.107 1.434 '1.363 1.463 1.619 1.644 1.914 2.04 1.57 1.624 1.553 2. IS 2.7S 5.46 1.497 1.603 1.733 3.77 4.-44 5.20 6.71 1.670 1.762 3.846 2.01 S.30 9.52 10.05 2.26 2.43 2.4 90 EU Area Pipe Lengtns 1.015 1.098 1.332 2.95 2.524 2.674 . . Long Radius EU Area LePnipgeths 1.055 1.340 .1.874 3.148 3.08 3.762 2.01 2.57 3.49 3.23 '3.41 3.807 2.16 2.76 3.74 3.473 3.665 4.08 3.96 4.64 5.02 3.782 3.938 3.834 4.28 4.99 5.46 4.087 4.236 4.170 5.47 6.99 S.62 3.756 4.031 4.318 6.02 7.76 9.73 4.134 4.475 4.874 9.76 11.44 13.58 17.73 4.324 4.541 4.82 5.31 11.09 13.17 15.60 18.76 4.913 5.228 5.538 5.622 22.31 25.2S 2; . IS 6.08 6 43 6.475 25.70 29.34 31.73 7.02 7.47 7.57S Area Tee ' Pipe Lengths 1.575 1.92S 2.68 4.578, 4.425 5.381 3 09 4.05 5.33 4.968 5.37S 5.S15 6.04 7.07 7.72 5.76S 6.001 5.897 S .52 10.64 12.33 5 .SSI 6.136 6.177 14.74 17.23 20.41 26.65 6.531 6.84 7.245 7.987 33.63 3S.04 40.94 9.18 9.68 9.775 Cross Area . 2.07 2.53 3.54. Length* . 6.02 5.816 7.108 . 4.06 5.17 6.95 6.528 6.865 7.582 7.89 9.24 10.07 7.535 7.843 7.692 10.97 13.75 16.83 7.534 7.929 8.431 18.97 22.10 26.26 34.11 8.405 8.773 9.322 10.222 43.15 48.79 52.35 11.75 12.4 12.5 255 CRMC-003619 Johns-Manville Service to Railroads Table of Decimal Equivalents OF MILLIMETERS AND FRACTIONS OF MILLIMETERS OF 8THS, 16THS, 32DS, AND 64THS OF AN INCH ' 'too = .0003937" mm. Inches ` :o = .00079 - so -- .00157 5 50 = .00236 s* = .00315 5/5o = .00394 so = .00472 -50 = .00551 so = .00630 S 'so = .00709 = .00787 n so = .00866 so = .00945 `5 io = .01024 'so = .01102 15 jo = .01181 >e 50 = .01260 i-'io = .01339 >5 so = .01417 ' jo = .01496 so so = .01575 -> so = .01654 "so = .01732 "'so = .01811 " so = .01890 so = .01969 Jfi so = .02047 50 = -02 1 26 "so = .02205 m so = .02283 m so = .02362 so = .02441 i- s., = .02520 so = -02598 si ;o = .02677 s'. 5,, = .02756 3" = .02835' . a: 3,, =='.02913 '> so = .02992 mm. Inches so = .03071 *oiso = .03150 *',-5o= .03228 `-'so = .03307 so = .03386 /jo = .03465 so = .03543 so = .03622 so = -03701 'jo = .03780 a, so = .03858 1= 23= 4= .03937 .07874 .11811 .1S748 5= 6= 7= 8= 9= .19685 .23622 .27559 .31496 .35433 10 = 11 = 12 -- 13 = 14= .39370 .43307 .47244 .51181 .55118 15 = 16 = 17 = 18 = 19 = .59055 .62992 .66929 .70866 .74803 20 = .78740 21 = .82677 22 = .86614 23 = '.90551 24= i.94488 25.= .98425 26 = 1.02362 mm. Inches 27 = 1.06299 28 = 1.10236 29 = 1.14173 30= 1.18110 31 = 1.22047 32 = 1.25984 33 = 1.29921 34= 1.33858 35 = 1.37795 36 = 1.41732 37 = 1.45669 38= 1.49606 39= 1.53543 40= 1.57480 41 = 1.61417 42 = 1.65354 43 = 1.69291 44 = 1.73228 45 = 1.77165 46 = 1.81102 47 = 1.85039 48 = 1.88976 49 = 1.92913 50 = 1.96850 51 = 2.00787 52 = 2.04724 53 =2.08661 54 = 2.12598 55 = 2.16535 56 = 2.20472 57 = 2.24409 58 = 2.28346 59 = 2.32283 60 = 2.36220 61 = 2:40157 62 = 2.44094 63 = 2.48031 mm. Inches 64 = 2.51968 65 = 2.55905 66 = 2.59842 67 = 2.63779 68 = 2.67716 69 = 2.71653 70 = 2.75590 71 =2.79527 72 = 2.83464 73 = 2.87401 74 = 2.91338 75 = 2.95275 76 = 2.99212 77 = 3.03149 78 = 3.07086 79 = 3.11023 80 = 3.14960 81 =3.18897 82 = 3.22834 83 = 3.26771 84 = 3.30708 85 = 3.34645 86 = 3.38582 87 = 3.42519 88 = 3.46456 89 = 3.50393 90 =3.54330 91 =3.58267 92 = 3.62204 93 = 3.66141 94 = 3.70078 95 = 3.74015 96 = 3.77952 97 = 3.81889 ' 98 = 3.85826 '99 = 3.89763 100 = 3.93700 lOmra. -- 1 Centimeter .= 0.3937 inches ,10 cm. ' =' 1 Decimeter = ,3.937 inches' ; - 10 dm. = 1 Meter = 39.37 inches 25.4 mm. = 1 English inch '../, 8ths xs = .125 )i = .250 A = .375 i.; = .500 = .625 % = .750 A = .875 lfiths ` 16 .0625 J 16 .1875 J 16 .3125 ` 16 .4375 j 16 .5625 "l6 = .6875 15 w = -8125 is, = .9375 32ds 'j, = .03125 8 a. = .09375 .15625 .21875 .28125 .34375 13^ .40625 ,s4 .46875 17-6 .53125 lt6 .59375 2 % .65625 M-4 .71875 2i-6 .78125 2'-4 .84375 .90625 814 .96875 64ths 16 = .015625 % = .046875 V6 = .078125 W4.= -109375, = .140625 . .171875 ;"i*6.= -203125 - .234375' 'Cl .265625 19'6 .296875 2'4l .328125 .359375 K4i .390625 .421875 .453125 3I4 = .484375 = .515625 35^ = .546875 = .578125 3Vi = .609375 ii / '61 _ -- .640625 = .671875 = .703125 _A4 7/6y4 -- .734375 = .765625 5'4 = .796875 53 ' -61 = -- .828125 a''61_ ~ .859375 a'.-4 -= .890625 59.' '64 = -- .921875 61 ' -- .953125 .984375 AL'ircumierences ana /\reas or v^ircies Diam: Cite/ Area Diam; . Circ. Area-. - Diain. -16 A- " 16 Jf 's *'w A 1 \f> * ' tic .0981 .1963 .3926 .5890 . .7854 .9817 1.178 1.374 1.570 1.767 1.963 2.159 2.356 2.552 2.748 2.945 '3;T-' .00076 .00306 ' .01227 < .02761 A :A .04908 .07669 : .1104 .1503 A .1963 4 .2485 A .3097 '.4 .3712 ' a .4417 .5184 .6013 3 34 .6902 ' 9;424 . 9;817 10.21' 10.6010/99 ' 11.38 1-1:78' 12.17 7.068 1 7 ' 7.669 8:295 ; 8:946 " 9:621 10:320 .: IS A 11.044 X 11.793 12.56 12,95. 13.35 13.74 14.13 14.S2 14.92 15.31 12.566 13.364 14.186 15.033 15.904 16.800 17.720 18.665 8 a u 1 3.141 .7854 V* 3.534 .9940 a 3.927 1.227 A 4.319 1.484 4.712 1.767 * i 5.105 2.073 A 5.497 2.405 ' H 5.890 2.761 2 a A a A 'b 6.283 6.675 7.068 7.461 7.854 8.246 8.639 9.032 3.141 3.546 3.976 4.430 4.908 5.411 5.939 6.401 5 H A A A /i A X 6 H H X rj J X y 15.70 16.10 16.49 16.88 17.27 17.67 18.06 18.45 18.84 19.24 19.63 20.02 20.42 20.81 21.20 21.57 19.635 20.629 21.647 22.690 23.758 24.850 25.967 27.108 28.274 29.464 30.679 31.919 33.183 34.471 35.784 37.122 9 !i ?4 10 Is M s '4 Circ.1 Area Diam. 21.99 22/38 ' 22.77-' 23.16. 23.56 23.95 24.34 24.74. 38.484 39/871 41.282 42:718 44.178 45:663 47:173 48.707 11 L.* \y \- j. 25.13 25.52 25.91 26,31' 26.70 27.09 27.48 27.88 50.265 51.848 53.456 55.088 56.745 58.426 60.132 61.862 12 y% >A :iy 1' 3' 28.27 28.66 29.05 29.45 29.84 30.23 30.63 31.02 63.617 65.396 67.200 69.029 70.882 72.759 74.662 76.588 13 \< H Y. 31.41 31.80 32.20 32.59 32.98 33.37 33.77 34.16 78.539 80.515 82.516 84.540 86.590 88.664 90.762 92.885 14 A Va /._ h 3-:* Circ. Area. Diam.- . Circ. 34.55 34.95 35.34 35.73 36.12 36.52 36.91 37.30 . 95.033 .97.205 99.402 101.62 103.86 106.13 108.43 110.75 15 !j ' H H] - ' 5; 47.12 47.51 47.90 48.30 ,48.69 49.08 .49.48 49.87 37.69 38.09 38.48 38.87 39.27 39.66 40.05 40.44 40.84 41.23 41.62 42.01 42.41 42.80 43.19 43.58 43.98 44.37 44.76 45.16 45.55 45.94 46.33 46.73 113.09 115.46 117.8S 120.27 122.71 12S.18 127.67 130.19 132.73 135.29 137.88 140.50 143.13 145.80 148.48 151.20 153.93 156.69 159.48 162.29 165.13 167.98 170.87 173.78 16 1< K ^ u s 17 1^ u l A `S 18 is U 1 50.26 50.65 51.05 51.44 51.83 52.22 52.62 53.01 53.40 53.79 54.19 54.58 54.97 55.37 55.76 56.16 56.54 56.94 57.33 57.72 58.11 58.51 58.90 59.20 Area'. Diam. Circ. . Area 176^71 . 19 179.67 182.72 1.85.66 188.69 'H u 1 .C It 191.74 194.82 A 197.73 59.69 60.08 60.47 60.86 61.26 61.65 62.04 62.43 283.52 287.27 291.03 .294.83 298.64 302.48 3C6.35 310.24 201.06 204.21 207.39 210.59 213.82 217.07 220.35 223.65 20 .n A .i j A 62.83 63.22 63.61 64.01 64.40 64.79 65.18 65.S8 314.16 318.00 322.C6 326.05 330.06 334.1C 338.16 342.25 226.98 230.33 233.70 237.10 240.52 243.97 247.45 250.94 254.46 258.01 261.58 265.18 268.80 272.44 276.11 279.81 21 N J A 22 lk A 15 ^ !> ' 65.97 66.36 66.75 67.15 67.54 67.93 68.32 68.72 69.11 69.50 69.90 70.29 70.68 71.07 71.47 71.86 346.36 3SC.49 354.65 358.84 363.05 367.26 371.54 375.82 380.13 384.46 388.82 393.2C 397.6C 402.03 406.49 410.97 256 CRMC-003620 i l Johns-Manville Service to Railroads Circumferences and Areas of Circles Diam. Circ. Area Diam. Circ. Area Diam. Circ. Area Diam. Circ. Area Diam. Circ. Area Diam. Ciic. Area 23 }s X3 . U ti H 72.2S 72.64 73.04 73.43 73.82 74.21 74.61 75.00 415.47 420.00 424.55 429.13 433.73 438.30 443.dl 447.69 34 X X Vs X Vs X V* 106.8 107.2 107.5 107.9 108.3 108.7 109.1 109.5 907.92 914.61 921.32 928.06 934.82 941.60 948.41 955.25 45 H X if Vs X 141.3 141.7 142.1 142.5 142.9 143.3 543.7 144.1 1S90.4 1599.2 1608.1 1617.C 1625.9 1634.9 1643.8 1652.8 56 Ys X X Vs H Xy$ 24 Vi X3 . X 25 X >4 J-3 X X 26 J< ?<' lA X Vs X X 75.39 75.75 76.18 76.57 76.96 77.36 77.75 78.14 452.39 457.11 461.86 466.63 471.43 476.25 481.10 485.97 78.54 78.93 79.32 79.71 80.10 80.50 80.89 81.28 490.87 495.79 500.74 505.71 510.70 515.72 520.70 525.83 81.68 82.07 82.46 82.85 83.25 83.64 84.03 84.43 530.93 536.04 541.18 546.35 531.54 556.76 562.00 567.26 35 X X Vs X Vs H Vs 36 X X H SA X Vs 37 X X X X X yi 109.9 110.3 110.7 lll.l 111.3 111.9 112.3 112.7 962.11 968.99 975.90 982.84 989.80 996.78 1003.7 1010.8 113.0 113.4 113.8 114.2 114.6 115.0 115.4 115.8 1017.8 1024.9 1032.0 1039.1 1049.3 1053.5 1060.7 1067.9 116.2 116.6 117.0 117.4 117.8 118.2 118.6 118.9 1075.2 1082.4 1089.7 1097.1 1104.4 1111.8 1119.2 1126.6 46 Li X X )K Vs X `/t 47 H X Vs X X X 48 X X 1> s.< X ys 144.5 144.9 145.2 145.6 146.0 146.4 146.8 147.2 147.6 148.0 148.4 148.8 149.2 149.6 150.0 150.4 150.7 151.1 151.5 151.9 152.3 152.7 153.1 153.5 1661.9 1670.9 1680.0 1689.! \698.2 1707.3 1716.5 1725.7 1734.9 1744.1 1753.4 1762.7 1772.0 1781.3 1790.7 1800.1 1809.5 1818.9 1828.4 1837.9 1847.4 18S6.9 1866.5 1876.1 57 Vs X Vs X Vs X 58 X X X l! X 59 Vs X X X Vs X 7i 27 X X H X : XX Vs : X VsX . ' Vi ' 84.82 572.55 85.21 577.87 85.60 583.20 86.00 588.57 86.39 . 593.95 86:78 599.37 87:17 604.80 '87.57 610.26 38 X :x Vs - 5i,;i. X>9 : 119.3 1134.1 119.7 1141.5' 120.1 1149.0 120:5 ' 1156.6 120:9' 1164.1 121.3 117.i:7 121.7 1179.3 I22:i. 1186.9' 49 . V}s: X .. >A xis x 87.96 615.73 : 88.35 621.26 . 88.75 .626.79 89.1-41 632.35 89:S3 637.94 . 89.92 643.54 "90.32 : 649.18 90.71 654.83 '39:. 122.5 1194.5 ' X 122.9; 1202:2 Xz.: . . 123.3- 1209.9 123.7."'1217.6- j j 124.0 1225.4. u,.. ' 124.4 1233:1.. 124:8:.' 1240.9 : .125.2 1248.7, 50 . Vs X ii* j4 H U-- 153.9 1885.7 154.3 1895.3 154.7 . 1905.0 155.1 1914.7 155.5 1924.4 155.9 1934.1 156.2 1943.9 156.6 .1953.6 60 Vs X u X .X Vs 157.0 . 157A- 157.8, - 158.2 158.6 159.0 . 159.4 . 159.8 1963.5 61 1973.3 : 1983.1 1993.0 x X Vs 2002.9 X 2012.8 2022.8 x 2032.8 29 X X . Vs X H a>'8; 91.10 91.'49 660.52 666.22 * :40\i'' ' '91.89 671.95 . x 92.28 677.71 92.67 683:49 93.06 689.29 ', X:: 3. . 93.46 695.12 S ' X - 193.85 700:98 125:6"- X256.'6126,0. 1264.:S'. 126.4 1272.3 ' 126.8 I2S0.3 127.2: 12S8;2. 127.6 129-1:2 1:28.0 1304.2 128.4 1312.2' 51 160:2 .. 3 s - .160.6. 731y 161.0 , 161.3 1,, 16i:7 ii < 162.1 X 162,5 162.9 2042.8 62 2052.8 2062.9 < X 2072.9 X 2083.0 . X 2093.2 2103.3 X 2113.5 ys 30; Vs H % X V 31 H X Vt X X A 94.24 94.,64 95.03 95.42 95.81 96.21 g6.60 96.99 706.86 '41 712.76 * t.?* ' 718.69 724.64 aX,; 730.61 736.61 X* . 742.64 748.69 X >9 97.38 97.78 98.17 98.56 98.96 99.3S 99.74 100.1 754.76 760.86 766.99 773.14 779.31 785.51 791.73 797.97 42 ) X X X 128.8 1 1320:2 129.1 1328.3' 129.5 1336.4 129.9 1344.5 130.3 1352.6 130.7 1360.8 131.1 1369.0 131.5 1377.2 ' 131.9 13S5.4 132.3 1393.7 132.7 1401.9 133.1 1410.2 133.5 1418.6 133.9 1426.9 134.3 1435.3 134.6 1443.7 >2 31" X V1 s' 51 x Vi 163.3 163.7 164.1 164.5 164.9 165.3 165.7 166.1 2123.7 '63. 2133.9 2144.1 2154.4 X X.1 ' 2164.7 Ys 2175.0 2185.4 X X 219S.7 ys 53 H X 3$ *i 5. 34 166-5. 166.8 167.2 167.6 168.0 168.4 168.8 169.2 2206.1 2216.6 2227.0 2237.5 2248.0 2258.5 2269.0 2279.6 64 A X X H Vs 32 X X X 2 % X Vs 100.5 100.9 101.3 101.7 102.1 102.4 102.8 103.2 804.24 810.54 816.86 823.21 829.57 835.97 842.39 848.83 43 X X l 55 X 135.0 135.4 135.8 136.2 136.6 137.0 137.4 137.8 1452.2 1460.6 1469.1 1477.6 14S6.1 1494.7 1503.3 1511.9 54 ?S X 1 A, X `$ 169.6 170.0 170.4 170.8 171.2 171.6 172.0 172.3 2290.2 2300.8 2311.4 2322.1 2332.8 2343.5 2354.2 236S.0 65 ! '4 X ii X7/ 33 M a X u x }n 103.6 104.0 104.4 104.8 10S.2 105.6 106.0 106.4 855.30 861.79 868.30 874.88 881.41 888.00 894.61 901.25 44 X l, s X 138.2 13S.6 139.0 139.4 139.S 140.1 140.5 14C.0 1520.5 1520.1 1537.S 1546.S 1555.2 1564.0 1572.8 1531.6 55 X 34 t ,, l V72.7 173.1 173.S 173.9 174.3 174.7 175.1 175.5 2375.8 2386.6 2397.4 2408.3 2419.2 2430.1 2441.0 24S2.0 66 Xi' 1 175.9 176.3 176.7 177.1 177.5 177.8 178.2 178.6 179.0 179.4 179.8 180.2 180.6 181.0 181.4 181.8 2463.0 2474.0 2485.C 2496.1 2507.1 2518.2 2529.4 2540.5 2551.7 2562.9 2574.1 2585.4 2596.7 2608.0 2619.3 2630.7 67 K l1 >> ?S H 68 X X X X X 210.4 210.9 211.2 211.6 212.0 212.4 212.8 213.2 213.6 214.0 214.4 214.8 215.1 215.5 215.9 216.3 3525.6 3538.8 3552.C 3565.2 3578.4 3591.7 3605.C 3618.3 3631.6 3645.0 3658.4 3671.8 3685.2 3698.7 3712.2 372S.7 81 }i a X 82 X1,; X 83 X }-i X 84 X 182.2 182.6 182.9 183.3 183.7 184.1 184.5 184.9 185.3 185.7 186.1 186.5 186.9 187.3 187.7 188.1 188.4 188.8 189.2 189.6 190.0 190.4 190.8 191.2 2642.0 2653.4 2664.9 2676.3 2687.8 2699.3 2710.8 2722.4 69 X X1 it >8 216.7 217.1 217.5 217.9 218.3 218.7 219.1 219.5 3739.2 3752.8 3766.4 3780.0 3793.6 38C7.3 3821.0 3834.7 2733.9 2745.5 2757.1 2768.8 2780.5 2792.2 2803.9 2815.6 70 IXt X1 ^ 5; X y'e 219.9 220.3 220.6 221.0 221.4 221.8 222.2 222.6 3848.4 3862.2 3875.9 3889.8 3903.6 3917.4 3931.3 3945.2 2827.4 2839.2 2851.0 2862.8 2874.7 2886.6 2898.5 2910.5 71 Ys :X .X i; X ! ;8 . 223.0 223.4 '223.8 224.2 224.6 225.0 225.4 225.8- 39S9.2 3973-1 '3987.1 4001.1 4015.1 ;4029.2 4043.2 4067.3 X 85 X U 66 X a 54 87 X X 88 X ii X 89 X X 191.6 192.0 192.4 192.'8 193.2 193.6 193.9 194.3 194.7 195.1 195.5 195.9 196.3 196.7 197.1 197.5 197.9 198.3 198.7 199.0 199.4 199.8 200.2 200.6 201.0 201.4 201.8 202.2 202.6 203.0 203.4 203.8 204.2 204.5 204.9 205.3 205.7 206.1 206.5 206.9 2922.4 2934.4 2946.4 2958:5 72 Vs . .X\ 226.1 .226.5 : 226.9 ; 4071.5 4085.6 4114.0 90 X X X 2970.5 2982.6 ... 2994.7 3006.9 x . 3X4'- ' 228:5" 91 X La 3019.0 3031.2 Vs . .' X "92 " 3043.4 X 3055.7 3067.9 3080.2 230.? `a " it 3092.5 3104.8 .232.0 4286.3 93 X .74 3117.2 w 3129.6 X 232.4. 232.8 233.2 4300.8 4315.3 4329.9 k 3142.0 233.6 4344.5 94 3144.4 X 234.0 ; 4359.1 . X 3166.9 234.4 4373.8 3179.4 3191.9 3204.4 3216.9 3229.5 3242.1 X Vs ' 75' X h X 234.8 .235.2 235.6 236.4 4388.4 4403.1 4476.9 4506.6 X 95 X X X 3254.8 3267.4 3280.1 3292.8 3305.5 76 239.5 240.3 241.1 4566.3 4596-3 4626.4 96 X X X 77 241.9 4656.6 97 3318.3 3331.0 3343.8 3356.7 3369.5 3382.4 3395.3 3408.2 x X X 78 *; 1j X 242.6 243.4 244.2 245.0 245.8 246.6 247.4 4686.9 4717.3 4747.7 4778.3 4809.0 4870.7 X X X 98 X Vi X 207.3 207.7 208.1 208.5 208.9 209.3 209.7 210.0 3421.2 3434.1 3447.1 3400.1 3473.2 34S6.3 3409.3 3512.5 79 l 80 ! ] {,, X 248.1 4901.6 99 250.S 251.3 252.1 252.8 253.6 499S.1 5026.5 5058.0 5089.5 5121.2 100 JX' it 254.4 255.2 256.0 256.8 5153.0 5184.8 5216.8 5246.8 257.6 258.3 259.1 259.9 5281.0 5313.2 5345.6 5378.0 260.7 261.5 262.3 263.1 5410.6 5443.2 5476.0 5508.8 263.8 264.6 265.4 266.2 5541.7 5574.8 5607.9 5641.1 267.0 267.8 268.6 269.3 5674.5 S707.S 5741.4 5775.0 270.1 270.9 271.7 272.5 5808.8 5842.6 5876.5 5910.5 273.3 274.1 274.8 275.6 276.4 277.2 278.0 278.8 5944.6 5978.9 6013.2 6047.6 6082.1 6116.7 6151.4 6186.2 279.6 280.3 281.1 281.9 6221.1 6256.1 6291.2 6326.4 282.7 283.5 284.3 285.1 6361.7 6397.1 6432.6 6468.2 .285.8. .,6503.8 286.6 6539.6 287.4 6575.5 288.2 . 6611.5 289.Q" 6647.6 289.8 6683.8 290.5 ' 6720.0 291.3 67S6.4 292.1 6792.9 292.9 6829.4 293.7 .6866.1 294.5 . 6902.S 295.3 296.0 296.8 297.6 6939.7 6976.7 7013.8 7050.9 298.4 299.2 300.0 300.8 7088.2 7125.5 7163.0 7200.5 301.5 302.3 303.1 303.9 7238.2 7275.9 7313.8 7341.7 304.7 305.5 306.3 307.0 307-8 308.6 7389.8 7427.9 7466.2 7504.5 7542.9 7581-5 310.2 311-0 313.3 314.1 314.9 315.7 316.* 7697.7 7736.6 7775.6 7814.7 7853.9 257 CRMC-003621 Johns'Martville Service to Railroads Fahrenheit and Centigrade Conversion Table Cent. 0 s 10 15 20 25 30 35 40 45 50 5S 60 65 70 75 80 85 90 95 100 105 no 115 120 125 130 135 140 . 145 ! 150 ;155 .160 165 : 170 175 180 185 ,190 105 !:: 200 205 . ! 210 215 220 225 Fahr. 32 41 50 59 68 77 86 95 104 113 122 131 140 149 158 167 176 185 194 203 212 221 230 239 248 257 266 .275 284 293 .302 -311;. i2q 329 .338 347 .356 365 374 3.83 3,92 .401 :41Q .419 428 437 Cent. Fahr. Cent. Fahr. 230 446 235 45S 240 464 245 473 460 860 465 869 470 878 475 887 250 482 255 491 260 500 265 509 480 896 485 905 490 914 495 923 270 518 275 527 280 536 285 545 500 932 505 941 510 950 515 959 290 554 295 563 300 572 305 581 520 968 525 977 530 986 535 995 310 590 315 599 320 608 325 617 540 1004 545 1013 550 1022 555 1031 330 626 335 635 340 644 345 653 560 1040 565 1049 570 1058 575 1067 350 662 580 1076 355 671 585 1085 360 680 590 1094 365 689 . 595 : U03 370 698 375 707 380 716 385 / -725; '600 1112 605 1121 r 610 1130 015 1139 390 '734 395 , >.'743 400 752 .405.- ; 76i . 620 ;.1148 625 1157630 1166 635 1175 ' 410 770 : 640 ; 1184 415 779 645 1193 .420 788 650 1202 ; 425. - 797: 655 : 1211 - 430 :435 ; 44p . -806 815 .824 660 : 1220 665 1229 670 1238 ' 445 833 ' 450 . . 842 455 - '851 . 67:5 ' 1247 680 ' 1256 -685 1265 Cent. Fahr. 690 1274 695 1283 700 1292 705 1301 710 1310 715 1319 720 1328 725 1337 730 1346 735 1355 740 1364 745 1373 750 1382 755 1391 760 1400 765 1409 770 1418 775 1427 780 1436 785 1445 790 1454 795 1463 800 1472 805 1481 810 1490 815 1499 820 1508 825 1517 830 1526 835 ; 1535 840 .1544 45 : :1553 850 >1562 855 ;l57l 860 ,1580 ; 865 ;1589 870 ;i598 875 1607 880' 1616 i 885 : 1625 890' 1634 ' 895: 1643 ' 900' v .1652 905 -1661 9io -1670 915 1679 Cent. 920 925 030 935 940 945 950 955 960 965 970 975 980 985 990 995 1000 1005 1010 1015 1020 . 1025 1030 1035 1040 1045 1050 1055 1060 1065 1070 1075 1080 1085 1090 1095 1100 1105 mo 1115 1120 1125 1130 1135 1140 1145 Fahr. Cent. Fahr. Cent. 1688 1697 1706 1715 1150 1155 1160 1165 2102 2111 2120 2129 1380 1385 1390 1395 1724 1733 1742 1751 1170 1175 1180 1185 2138 2147 2156 2165 1400 1405 1410 1415 1760 1769 1778 1787 1190 1195 1200 1205 2174 2183 2192 2201 1420 1425 1430 1435 1796 1805 1814 1823 1210 1215 1220 1225 2210 2219 2228 2237 1440 1445 1450 1455 1832 1841 1850 1859 1 1230 1235 1240 1245 2246 2255 2264 2273 1460 1465 1470 1475 1868 1877 1886 1895 . 1250 1255 1260 1265 2282 2291 2300 2309 1480 1485 1490 1495 1904 1913 1922 1931 1270 1275 . 1280 . 1285 2318 2327 2336 2345 1500 1505 1510 ' 1515 1940 1290 1949 1295 1958 1300 1967 - 1305 2354 2363 2372 2381 1520 1525 1530 . 1535 1976 1985 1994 2003 1310 1315 1320 1325 : 2390 2399 \.:.2408'.- . ' , 2417. 1540 1545 1550 1555 2012 2021 2030 2039 . 1330, ,1335 1340 - 1345' 2426 2435. 2444 2453 1560 x 1565 1570 1575 2048 ;1350 2462 2057: ' .1355 ; .2471 2066, 1360 2480 1580 : 1585 1590 2Q75 ' 2084 2093 v 1365 ,1370 1375 2489 2498 2507 > 1595 1600 Fahr. 2516 2525 2534 2543 2552 2561 2570 2579 2588 2597 2606 2615 2624 2633 2642 2651 2660 2669 2678 2687 2696 2705 2714 2723 ~ 2732 2741 2750 2759 2768 2777 2786 2795 2804 2813 2822 2831 2840 2849 2858 2867 2876 2885' 2894; 2903 2912 Metric Conversion Table Millimetres y. .03937 -- inches. Millimetres -r 25,4 inches.1 Centimetres X .3937 cr inches. Centimetres ~ 2.54 inches. Metres X 39.37 =r inches. (Act of Con gress.) Metres X 3.281 = feetMetres X 1.094 = yards. Kilometres X -621 miles, Kilometres ~ 1.6093 =: miles. Kilometres X 3280.8693 = feet. Square Millimetres X .00155 = sq. inches. Square Millimetres ~ 645.1 = sq. inches. Square Centimetres X .155 = sq. inches. Square Centimetres -X 6.451 -- sq. inches. Square Metres X 10.764 = sq. feet. Square Kilometres X 247.1 = acres. Hectare X 2.471 = acres. Cubic Centimetres-7- 16.383 = cubic inches. Cubic Centimetres -f- 3.09 -- il. drams (U.S.P.) Cubic Centimetres -r- 29.57 =; fluid ounce <U.S.P.> Cubic Metres X 35.315 =; cubic feet. Cubic Metres X 1.308 = cubic yards. Cubic Metres X 264.2 = gallons (231. cubic inches.) Litres X 61.022 = cu. in. (Act of Con gress.) Litres 33.84 = fluid ounces (U.S.P.) Litres \ .2642 = gallons (231. cu, in) Litres -f- 3.78 = gallons (231. cu. in.) Litres -r- 28.316 = Cubic leet. Hectolitres X 3.531 =: cubic feet. Hectolitres X 2.84 =.bushels (2150.42 cu. inches.) Hectolitres X .131 =; cubic yards. Hectolitres d-26.42 = gallons (231. cu. in.) Grammes X 15.432 = grains. (Act of Congress.) Grammes 961. -- dynes. Grammes twater) -r- 29.57 = fluid ounces. Grammes 28.35 ounces avoirdupois. Grammes per cu. cent, -j- 27.7 = lbs. per cubic inches. . Joule x .7373 = foot pounds. Kilo-grammes X 2.2046 = pounds. Kilc-grammes X 35.3 := oz. avoirdupois. Kilo-grammes -r- 907.2 = tons (2,000 lbs.) Kilo-grammes per sq. cent. X 14.223 = lbs. per sq. in. KiJo-gram-metres X 7.233 = foot lbs. Kilo-gr. per Metre X .672 -- lbs. per foot. Kilo-gr. per Cu. Metre X .062 = lbs. per cubic feet. Tonneau X 1.1023 tons (2.000 lbs.) Kilo-Watts X 1-34 = Horse Power. Watts -f- 746. = Horse Power. Watts X .7373 = foot pounds per second. Calorie 3.968 = B. t. u. Chcval vapeur 4- .9863 Horse Power. ^Centigrade X 1.8) -1- 32 degree Fahr. Gravity Paris = 980.94 centimetres per sec. 258 CRMC-003622 Johns-Manville Service to Railroads INDEX A Page Accessories, Roofing ............................................................... 185 Acid-proof Industrial Flooring .................................. 217-218 Acme-Keystone Hair Insulator ......................................... 205 Acoustical Correction, Architectural .............................226 Aertite Boiler Wall Coating ................................................. 59 Air Brake Packing Cup Expander Ring ...................... 74 Air Pump Gaskets, Top Head and Bottom Head ... 90 Air Pump Lagging, 85% Magnesia ............................... 40 Air Pump Packing, --Kearsarge .............................................. 77 --Keystone ................................................................................ 79 --Moulded .................................................................................. 79 --Special Combination ....................................................... 78 Anti-Sweat Sectional Pipe Insulation ........................... 29 Appendix .......................................................................................... 247 Approval of Roofings by Underwriters .......................... 120 Aquadam (for waterproofing) ........................................... 223 Architectural Acoustics, Correction of ............................226 Arctic-Keystone Hair Insulator ......................................... 205 Areas and Circumferences of Circles .............................. 256 Areas, of Flanged Fittings, Radiation ............................255 Asbestocel, Improved, Pipe Insulation ....................... 21-22 --Sheet & Block Insulation ............................................ 42 --Insulation (Flexible Roll Form) ............................. 42 Asbestoment and Niagrite Cable Insulation .............. 243 Asbesto-Metallic, --Friction Blocks ... 104 --Gasketing Tape ........................ - 87 --Gaskets* Manhole, Handhole. & Tube Plate .... 86. --Sheet- Packing, Kearsarge ..................... : 85 --Tubular Gasketing,- Kearsarge . ........... ..'87 .Asbestos Braided Rope Packing .'. ;73 Asbestos Braided Tubing ... . ...........242 -Asbestos Brake-Lining, Non-Burn, Industrial .. ... .".107 . .Asbestos Clothing '.. .. !.. . ; V.... . .. ........ .246 Asbestos Combination Spiral. Pipe Insulation 26 Asbestos Cord .'73 , Asbestos .F.eltj ' Slater's - . V..'--a. .... .......... 186- i Asbestos.' Felt, - Waterproofing 221 - : Asbestos Fibrous 'Enamel ........ ................ 1.85 .. ' Asbestos Fire Felt --Insulating Cement' No. 302 v.;........... ............... ..- 501: ;--Pipe insulation' . .. -........... ........................................... 24 ' --Roll V......... ........................................................... ................ 45 --Sheet & Block insulation ............................................ 43 Asbestos Flexible Pipe Insulation ...................... 25 Asbestos Furnace 'Cerneiit, Fireite ................................... 60 Asbestoside, Asbestos Exterior Wall Siding ............. 146 Asbestos Insulating Cements, Nos. 302. 352. 364, 400. . 50 Asbestos Lead Joint Runner ............................................... 246 Asbestos Paper & Roll Board ............................................ 47 Asbesto-Sponge Felted Insulations, --Sectional Pipe ..................................................................... 10 --Sheet & Block Insulation............................................... 39 --Train Pipe Insulation ..................................................... 11 ASBESTOS ROOFINGS --Asbestos ProtectedMetal ................................................159 --Barge ........................................................................................150 --Built-up ................................................................................... 128 --FlexstoneReady-to-lay ..................................................... 142 Page --Locomotive Cab .................................................................. 149 --Transite Corrugated ......................................................... 151 Asbestos Roof Putty ................................................................186 Asbestos Sheet Millboard .........................................................47 Asbestos Slater's Felt ............................................................. 186 ASBESTOS SHINGLES --Flexstone Brand (slate surfaced) .............................179 --Standard and Colorblende (Rigid) ........................ 167 Asbestos, Story of ..................................................................... 6 Asbestos Stove Lining, Phoenix ......................................... 60 Asbestos Waterproofing Felt ..............................................221 Asbestos Wick & Rope Packing ........................................ 73 Asbestos Wood, --Ebony ....................................................................................... 223 --Caps & Stacks, Transite ................................................ 199 --Smoke Jacks, Transite ........................................193-198 --Transite (Flat) for building purposes .................... 188 --Transite (Flat) for electrical purposes ...................230 --Ventilators, Transite ....................................................... 199 Asphalt Roofing Cement ......................................................... 186 Asphalt Saturated Fabric ....................................................... 221 Asphalt Waterproofing Cement ......................................... 221 B Baffle Walls* Monolithic .................. 58 Bare Pipes and other Bare Surfaces, Losses from, etc. 249 Barge Roofing, Asbestos .150 Bituminous .Putty ................................................. . :222 Blocks,! Asbesto-Metallic Friction ... .............. .1104 Block & Sheet,Insulation, --Asbestpcel,. Improved .... *; ............-..'..; 42 --Asbestocel,. Flexible Roll Form ..................................... 42 --Asbestos Fire Felt. ................................... 43 --Asbesto-Sponge .Felted 39 --85% Magnesia V. ..; -:,40 --List Prices'.. . .. -. I";';:-. ......... >'. - - . 49 --Millboard, Asbestos . -.;........... .....; 47 --Thermo Fire^Felt ... l . .. .........44 --Vitribestos ; :v. '.. . .. ......... .. 46 --Vitro -Fire ; Felt ............ ............... .'.. i.45 --Weights' and Standard.:'Sizes . 49 Board (Roll.and Paper, Asbestos) .47 Boiler Lagging,. Locomotive; 85% Magnesia ....... 40 Boiler Manhole Gaskets, Kearsarge Asbesto- Metallic .............. 86 Boiler Wall Coating, Aertite.................. 59 Brake Lining, Non-Burn Asbestos, Industrial .............107 Brake Blocks, Asbesto-Metallic .......................................... 104 Brine and Ammonia, Insulation Built-up ....................... 27 Brooks Brand (White Top) Asbestos Ready-to-lay Roofing ..........................................................................................143 Building Insulation (Keystone Hair Insulator) ....202 Built-up Asbestos Roofing ..................................................... 128 Built-up Hair Felt Insulation ............................................. 28 c Cab Cock Packing, Locomotive .............. Cable Insulation, Niagrite Fireproof .. . Cab, Locomotive, Asbestos Roofing for Cab Roof Insulation, Locomotive ........... 77 243 149 97 259 CRMC-003623 Johns-Manville Service to Railroads Page Carinsul, Steel Passenger Car Insulation ...................... 95 Car Insulation, Refrigerator, Hairinsul ........................ 98 Car Insulation, Steel Car, SalamanderBrand ................ 92 Car Insulation, Tank Car .......................................................101 Ceilinite. Railroad Car Insulation...................................... 94 CEMENTS --Asbestos Insulating, Nos. 302, 400, 352, 364 .... SO --Asphalt Roofing .................................................................186 --Asphalt Waterproofing ................................................. 221 --85% Magnesia, Insulating .......................................... 50 --Fireite Asbestos Furnace ............................................. 60 --Fire Felt, No. 302 ............................................................... 50 --H-O Pipe Joint................................................................... 60 --Insulating .............................................................................. 50 --Pickling Tank ...................................................................... 222 --Refractory or High Temperature, Nos. 20, 26, 30, 31, 32, 33 & 35 ............................... 51-5B --Super-refractory, Nos. 33 & 35 ................................. 56 --Waterproofing, Asphalt ................................................221 --Self-Healing, Waterproofing .......................................222 Centigrade and Fahrenheit Conversion Tables............ 258 Chemical Fire Extinguisher, Success ........................... 245 Circles, Areas and Circumferences .................................... 256 Clothing, Asbestos ...................................................................... 246 Coating, - --Aertite Boiler Wall ...... v.'.......................... 59 --Liquid Waterproof ;................ 223 --Regal Roof ..V....-. . . . . . ........................185 Coil Packing, Mogul. ..V... ..... . . ........................................ 68 Cold Water Paint ....... -......... ................... 186 "Colorbleride" andStandard- Asbestos-Shingles (rigid) , . v.. . . : VV V ^ ......... .. ..167 " Combination.Air Pump Packing, Special ..... .. . 78 " Combination.' Spiral Pipe; Insulation .................................. 26. Compound; Leak-no Metallic...... / ...... 60 Compounds, Rubber "'Splicing-'.".' . ...:.. . .242 ".Concrete '''Primer .. .TV.:.-;-://';;-:/T-.V./ .'221. Conduit,. Orangeburg Fibre -C:.; V;/" TV.......... .231 Conversion Table, Centigrade ,&' Fahrenheit ........258 ' Conversion; Table, Metric'-; /. T. >1 T.. ..:.. .. .............. . .258 Cord, Asbestos ... , Tv;... .................. 73 Correction of Architectural .Acoustics ..............................226 Corrugated Asbestos Protected Metal Roofing and Siding ......... ... T.;.. TT... /........... .......................... 159 Corrugated- Asbestos .'Roofing, and Siding, Transite .. 151- Covering,' Sill ...........v;. v V.............................. ioo Cut Stone. Backing ......... ..................................... ;223 D Damp-proofing .............................. 222 Data on Wrought Iron and Steel Pipe ......................... 254 Decimals, Equivalents of ......................................................... 256 Double Coated Asbestos Ready-to-lay Roofing, Flexstone ......................................................................................142 Duct, Underfloor, Orangeburg System of ..................... 236 Duplex Rod & Plunger Packing ........................................ 67 E Ebony Asbestos Wood ........................................................... 228 --technical data ...................................................................... 229 Page Efficiencies, --Asbesto-Sponge FeltedPipe Insulation ...............15-16 --Asbesto-Sponge-Felted Sheets and Blocks .... 48 --85% Magnesia Blocks ................................................... 48 --85% Magnesia Sectional Pipe Insulation......... 19-20 --Thermo Fire Felt, Sheets & Blocks ......................... 48 Efficiency Tables, How to Use......................................248 85% Magnesia Cement............. ............................................... 50 85% Magnesia Blocks, Weights of .................................. 49 85% Magnesia Locomotive Boiler and Air Pump Lagging ...................................................................................... 40 85% Magnesia Sheet & Block Insulation.......................40 Enamel, Asbestos Fibrous ................................................185 Equivalents and Radiation Areas of Standard Flanged Fittings ......................................................................255 Equivalents of Decimals, Table of .....................................256 Excello-Keystone Hair Insulator .....................................206 Expander Ring, Slip Type for Packing Cups ............. 74 Expansion Joint Filler .............................................................222 Express Brand, Wool Felt Pipe Insulation ............... 31 Extinguishers, Fire, Success Chemical ......................... 245 F Fabric, Asphalt Saturated ...................................................... 221 Fahrenheit and Centigrade Conversion Tables ............ 258 Fasteners, Roofing, Pyramid Kap ......................................143 Felt, Asbestos Slater's 186 Felt, Asbestos Waterproofing 221 Felt, Hair, Standard ............................... 100 Ferrotite Cement ............ 60 Fibre Conduit, Orangeburg. ...................................................231 : Fibrous Enamel, Asbestos ..................... 185 Filler, Expansion Joint. ...;...... . 222 ----- Fire Felt, --Asbestos Insulating .Cement No. 302 -........... ..... 50 --Asbestos Roll,-Plain or Indented 45 -- -^-Asbestos Pipe Insulation' .. 24 ---Asbestos Sheet & Block Insulation . .... .............. 43 --Thermo Sheets and Blpcks ............ 44 ' --Vitro, Sheets and .Blocks:........ .............. 45. - Fire Extinguisher, . --Success Chemical-.:-;.V./. .'.7...................................... 245 ' --Success Non-Freezing, . ........................245 Fireite Asbestos Furnace. Cerfient .............. ............ 60 Fireproof Cable Insulation, Niagrite .................................243 Flanged Fittings, Radiation areas and equivalents ..255 Flange Joint Gaskets, Service and Seigelite ................ 88 Flashings and Gutters, Details of,.:...................... 138-140 Flexstone Asbestos Ready-to-lay Roofing ................... 141 Flexstone Asbestos Shingles (Slate Surface) ...............179 Flexstone Double Coated Asbestos Ready-to-lay Roofing ........................................................................................ 142 Flooring, --Industrial ................................................................................ 210 Friction Blocks, Asbesto-Metallic ..................................... 104 Friction Tapes ............................................................................ 241 Furnace Cement, Fireite Asbestos .................................... 60 G Gasketing, Tape, Kearsarge Asbesto-Metallic ............ 87 Gasketing, Kearsarge Asbesto-Metallic, Tubular ... 87 Gaskets --Air Pump, Top Head and Bottom Head .............. 90 260 CRMC-003624 Johns-Manville Sendee to Railroads Gaskets (cont.) Page Page --Jointless Tube Plate, Kearsarge ............................. 86 --Steam Pipe Insulation, Minimum Thicknesses --Kearsarge Asbesto-Metallic Boiler Manhole, for various services ...........................................................253 Handhole & Tube Plate ................................................. 86 --Service and Seigelite Flange Joint ........................... 88 --Tank Car Insulation ......................................................... 101 --Thermo Fire Felt Sheet & Block Insulation ... 44 --Water Gauge ........................................................................ 89 --Train Pipe (Asbesto-Sponge) .................................... 11 Gutters, Built-up, Details of .................................................. 139 --Underground System of Insulation ........................ 33 Gypsum Roof Decks, Specifications for Built-up --Vitribestos Sheet & Block .......................................... 46 Roofing .....................................................................132 and 134 --Vitro Fire Felt .................................................................... 45 --Weights of Sectional Pipe Insulations .................. 32 H --Weights of Sheet & Block Insulations ..................49 Hair Felt Insulation, --Wool Felt Insulation ...................................................... 31 --Built-up, pipe ...................................................................... 28 --Zero Sectional Pipe Insulation ............................. 31 --Standard, refrigerator car ..............................................100 Insulator, Keystone Hair .........................................................202 --for Buildings, (Keystone) ............................................. 202 Integral Waterproofing ...........................................................220 Hairinsul, Refrigerator Car Insulation......................... 98-99 Iron and Steel Pipe, Data on ...............................................254 Handhole, Manhole and Tube Plate Gaskets, Kearsarge Asbesto-Metallic ............................................. 86 Heat Losses from Uninsulated Hot Surfaces ............ 253 Heat Losses per Lineal Foot of Bare Pipes, etc.......... 249 High Temperature or Refractory Cements, Nos. 20, 26, 30, 31, 32, 33 and 35 ................................. 52-58 H-O Pipe Joint Cement.......................................................... 60 Hot Surfaces, Heat Losses from Uninsulated ............ 253 How to use Tables of Insulation Efficiencies............. 248 J Jacks, Transite Asbestos Wood Smoke ................. 193-198 Jewett Ring Packing ................................................................. 71 Joint Filler, Expansion ...........................................................222 Joint, Flange Gaskets, Service andSeigelite ................ 88 Jointless Tube Plate Gaskets, Kearsarge...................... 86 Joint Runner, Asbestos Lead ..............................................246 Junior Steam Traps .................................................................. 113 K I Kaps, Pyramid 143 Industrial Brake-Band Lining, Non-Burn Asbestos .107 Industrial Flooring ........... 210 INSULATING CEMENTS J ' : Kearsarge Air Pump Packing ............................................ 77 Kearsarge Asbesto-MetaUic Gasketing Tape ..................-87 Kearsarge Asbesto-Metallic Manhole, Handhole and Tube Plate Gaskets ......... :.. 85 Asbestos. Nos.^ 352, 364.and.400. ............. ................... 50 .Fire,-Felt No, 302 50 Kearsarge Asbesto-Metallic Sheet Packing 85 -Kearsarge Asbesto-Metallic Tubular Gasketing .... 87- 85%; Magnesia ................... 50 Kearsarge Join'tiess;.;Tube Plate Gaskets ........... 86 Insulated Roof .Decks;. .:,... .... i.................130' Kearsarge Locomotive Throttle Packing......... .............: 81: INSULATIONS % - ........... ..Insulation, Object of ...,.. . . .. 9 --AntLSweat Sectional Pipe 29 Kearsarge Rpd Packing '. . ;.............. ............. ...................... 66 Keystone Air Punipf Packing '.;......... .. . 79 Keystone Hair Insulator .................... . . 202 --Asbestos Fire Felt Sectional. ............................... ;.. 24 --Asbestocel Flexible ..Roll Form ,.............. ...... 42 . Lagging, Locomotive .Boiler, 85% Magnesia ...____40 . --Asbestos Flexible,:S;team::Pipe. Insulation . . 25. Lagging, Locomotive and Air .Pump, 85% Magnesia. .40 . --Asbesto-Sponge Felted. Sectional Pipe ........... ; 10 -Lead Joint Runner,. Asbestos ........................... . 246 ---Asb,esto-Sponge; Felfedr'Sheets & Blocks ................. 39 .--Asbesto-Sponge -Felted .-Train Pipe, Sectional .; 11 Leak-no Metallic Compound 6b .Liberty Red Rubber Sheet Packing ............... ......... 85 --Asbestos Paper. & Roll Board :........ 47 - Lining, Non-Burn Asbestos Drake Band, Industrial, 107 --Asbestos Roll Fire Felt .v:. ..... . ............................... 45 --Building Insulation (Keystone) ................................ 202 Lining, Asbestos .Stove, Phoenix ;.........................; 60Liquid Waterproof Coating ................................................223 --Built-up Brine and Ammonia ...................................... 27 LIST PRICES , --Built-up Hair Felt ......... ................................................... 28 --Ebony Asbestos Wood ...................................................229 --Carinsul Steel Passenger Car Insulation ............. 95 --Industrial Brake Band Lining, Non-Burn --Ceilinite Railroad Car Insulation ............................. 94 Asbestos ................. ;.....................................................107-108 i --Combination Spiral Pipe Insulation, Asbestos .. 26 --Orangeburg Fibre Conduit ......................................... 234 --85% Magnesia Sectional Pipe .................................... 17 --Sectional Pipe Insulation ............................................. 32 --85% Magnesia Blocks ................................................... 40 --Sheet & Block Insulation ............................................ 49 --Hairinsul Refrigerator Car Insulation ............98-99 --Transite Asbestos Wood ............................................. 230 --Improved Asbestocel Sectional Pipe ...................... 21 Locomotive Boiler and Air Pump Lagging, --Improved Asbestocel, Fine Corrugated, 85% Magnesia .......................................................................... 40 Sectional ................................................................................ 22 Locomotive Cab Cock Packing ........................................... 77 --Improved Asbestocel, Sheets and Blocks ........... 42 Locomotive Cab Roofing, Asbestos.................................. 149 --Locomotive Cab Roof Insulation .......................... 97 Locomotive Cab Roof Insulation .................................... 97 --Minimum thicknesses for various services .........253 Locomotive (Mallet) Packing ............................................. 76 --Niagrite Fireproof Cable Insulation ......................243 Losses due to Steam Leakage ..............................................252 --Nycinsul Steel Passenger Car Insulation ........... 95 Losses from Bare Pipes and Other Bare --Roll Fire Felt ..................................................................... 45 Surfaces, etc................................................................................. 249 --Standard Hair Felt Insulation ...................................100 Losses Heat from Uninsulated Hot Surfaces ............ 253 261 CRMC-003625 Johns-Manville Service to Railroads M Page Magnesia, 85% Cement ........................................................... 50 Magnesia, 85% Locomotive Boiler Lagging ............. 40 Magnesia, 85% Locomotive Air Pump Lagging .... 40 Magnesia, 85% Sectional Pipe Insulation .................... 17 Magnesia, 85% Block Insulation......................................... 40 Mallet Locomotive Packing .................................................. 76 Manhole, Handhole and Tube Plate Gaskets, Kearsarge Asbesto-Metallic .............................................. 86 Metric Conversion Table......................................................... 258 Metallic Compound, Leak-No .............................................. 60 Millboard, Asbestos Sheet ................. 47 Millimeters and Fractions of Millimeters, Decimal Equivalents- of ....................................................... 256 Mineral Surfaced Roofing, Asbestos Ready-to-lay, Flexstone ......................................................................................142 Minimum Thicknesses of Steam Pipe Insulation ,. .253 Mobilene Sheet Packing ......................................................... 85 Mogul Coil Packing ................................................................. 68 Monolithic Baffle Walls ........................................................... 58 Moulded Air Pump Packing.................................................. 79 N Neptune Brand, Keystone Hair Insulator ................... 205 New York Air Pumps, Packing for .................................. 80 Niagrite and Asbestoment Fireproof Cable Insula tion 243 NonrBurn Asbestos Brake Lining, Industrial .............107 Non-Freezing Fire Extinguishers, Success ................... 245 Nycinsul, Railroad Car Irisulatipn ........ . . ^ . 95 o Orangeburg Fibre Conduit........... ....................... .231 Orangeburg Underfloor Duct .System ........................... .236 v P PACKINGS. r - , --Air Pumpi .Special Combination ;:......... 78 --Air - Pump, Kearsarge ; . ......................... 77 --Air Pump,''Keysfone:................... 79 --Air Pump, Moulded .... - :............................... 79 --Asbesto-Metallic; Gasketing-. Tape ........... . 87. . --Asbesto-Metallic;GasketSs Kearsarge .. 86 --Asbesto-Metallic; Sheet, Kearsarge .................. 85 --Asbesto-Metallic Tubular, Kearsarge ....... .... 87 --Asbestos Braided Rope. 1................... 73 --Asbestos Wick ......................................... 73 --Coil, Mogul .................. 68 --Combination Air Pump, Special ..............................- 78 --Duplex Rod & Plunger . .................. 67 --Gasketing, Asbesto-Metallic Tape ............................ 87 --Gasketing, Asbesto-Metallic Tubular ....................... 87 --Gaskets, Kearsarge Asbesto-Metallic ..................... 86 --Gaskets, Kearsarge, Jointless .................................... 86 --Jewett Ring .......................................................................... 71 --Kearsarge Air Pump 77 --Kearsarge Asbesto-Metallic Boiler, Manhole. Handhole & Tube Plate Gaskets ......................... --Kearsarge Asbesto-Metallic Gasketing Tape . --Kearsarge Asbesto-Metallic Gaskets, jointless 86 87 86 87 85 79 85 77 Page --Locomotive Throttle, Kearsarge ............................. 81 --Mallet Locomotive ........................................................... 76 --Mobilene Sheet .................................................................. 85 --Mogul Coil ............................................................................ 68 --Moulded Air Pump ....................................................... 79 --Piston, Universal ................................................................ 69 --Plunger & Rod, Duplex ................................................ 67 --Plunger & Rod, Universal............................................ 72 --Power Reverse Gear, Piston ..................................... 75 --Pump Valves Moulded, No. 206 .............................. 90 --Pump Valves Rubber .................................................... 90 --Pump Packing Recommendations ............................ 82 --Red Rubber Sheet, Liberty .......................................... 85 --Reverse Gear Piston ..................................................... 75 --Rod & Plunger, Universal .......................................... 72 --Rod & Plunger, Duplex ................................................ 67 --Rope & Wick....................................................................... 73 --Rubber Pump Valves .................................................... 90 --Sea Ring .................................................................................. 62 --Seigelite Sheet, Style No. 711 ................................... 84 --Seigelite Gaskets, Style No. 712 .............................. 88 --Service Gaskets, Style No. 61 ................................. . 88 --Service Sheet, Style No. 60.......................................... 83 --Special Combination Air Pump .............................. 78 --Universal Locomotive Throttle Packing ............. 81 --Universal Piston.................. ...... ;.................................... 69 --Universal Rod & Plunger ............................................ 72 --Universal Combination Steam Hammer .............. 70 --Valves, Pumpi Moulded,. No. 206 .............................90 --Valves, Pump, Rubber..................................... --Wick & Rope ........................................... .......................... 73 Packing Cup Expander Ring Paint, Cold Water . .............. .......... 186 Paper & Roll Board, Asbestos ..................! ... 47 Passenger. Car1 (Steel) Tnsulatibn. . ................................ 92 Peerless-Keystpne Hair Insulator .................................... 205 Phoenix Asbestos Stove Lining Phoenix-Keystone Hair Insulator . ............. ............ .205 Pickling Tank; Cement ... . ................222 Pipe Insulation Efficiency Tables. How to Use .... 248 PIPE INSULATIONS ' 90 74 60 --Anti-Sweat Sectional. . ^ ............. 29 --Asbestos Combination.. Spiral 25 --Asbestos Fire Felt, Sectional.......... ........................... 24 --Asbestos Flexible Pipe ...... .................................... 25 --Asbestd-Sponge Felted Sectional ....................... 10 --Asbesto-Sponge Felted Train. Pipe, Sectional ... 11 --Built-up Brine and Ammonia . .................................... 27 --85% Magnesia Sectional ................................................ 17 --Fire Felt Sectional ............................................... ... 24 --Improved Asbestocel Fine Corrugated, Sectional 22 --Improved Asbestocel, Sectional ................................... 21 --List Prices ............................................................................. 32 --Minimum Thicknesses of, for Various Services .253 --Underground System of............................. ............. 33 --Weights of Sectional ............................... ............. 32 --Wool Felt, Sectional................................... ............. 31 --Zero, Sectional ............................................ ............. 31 Pipe Joint Cement, H-0 ................................... ........... 60 Pipe, Data on Wrought Iron and Steel.......... ........... 254 Piston Packing, --Power Reverse Gear................................... ........... 75 --Universal ........................................................ 262 CRMC-003626 Johns-Manville Service to Railroads Page Plunger & Rod Packing, --Duplex ..................................................................................... 67 --Kearsarge ............................................................................... 66 --Universal ................................................................................. 72 Price List, Non-Burn Asbestos Brake Band Lining .................................................................................... 107-108 --Orangeburg Fibre Conduit............................................234 --Sectional Pipe Insulations..............1............................. 32 --and Weights, EbonyAsbestosWood ......................... 229 --and Weights, Transite AsbestosWood ................. 230 --and Weights, Sheet and Block Insulations ......... 49 Primer, Concrete .........................................................................221 Pump Packing Recommendations .................................... 82 Pump Valves, Rubber ............................................................. 90 Putty, Asbestos Roof ..............................................................186 Putty, Bituminous .......................................................................222 Pyramid Kaps, Roofing Fasteners ..................................... 143 R Radiation Areas and Equivalents of Flanged Fittings ................................................................... 255 Radiator Trap ................................................................................ 114 Rag-Felt Ready-to-lay Roofings ..........................................183 Rail Covering (Third Rail) .................................................. 244 Railroad Car Insulations ............................. 92-102 READY-TO-LAY ASBESTOS ROOFINGS --Flexstone (smooth or slate surfaced) ................... 142 --White Top .................. ........................................................ 143 :Red Rubber Sheet Packing, Liberty . ............................. 85 Refractory -Cements .................................................... 51-58 .Refrigerator Car Insulation . 98 Regal Roof . Coating ./;.................................................. 185 Registration, Roof .... /...': L..................119 Re-roofing- over old wooden shingles .................. 170 Retort Cement .' v.'...... ... ................................. .. 55 Reverse Gear'Piston Packing .;............. ............................ 75 Ring, Expander,-Slip Type. .................... 74 Ring ..Packing, Jewrett . ;... .. ........... 71 Ring; Packing, Sea .Ring '............................. 62 Rod Packing, :Kearsarge:;;/............. ............................. 66 Rod & Plunger: Packings, : . --Duplex -l. --r'Kearsarge:.v................ --Universalvi.y....... ... ........... 72 Roll. Board and-Paper, Asbestos ;, -. Roll Fire. Felt; Asbestos-Plain, or Indented ........... 67 66 47 45 Roof Coating, -Regal ....... ............ I.... ....................185 Roof Decks, Insulated ......... : 130 Roof Insulation, Locomotive Cab....................................... 97 Roofing Cement, . Asphalt ........................ 186 Roofing Fasteners (Pyramid Kaps) ................................. 143 Roof Putty, Asbestos .............................................. 186 ROOFINGS --Built-up Asbestos ..............................................................128 --Barge, Asbestos ............................. f................................ 150 --Flexstone, Slate Surfaced Asbestos .......................... 142 --Locomotive Cab, Asbestos ............................................ 149 --Rag-Felt, Ready-to-lay ...................................................183 Roofing and Siding, Asbestos Protected Metal.........159 Roofing and Siding, Asbestos, Transite Corrugated .151 Roof Registration ................................. 119 Roofs, "Colorblende" ....................................................... 171-174 Rope & Wick Packing, Asbestos....................................... 73 Rosin Sized Sheathing .............................................................. 100 Page Rubber Pump Valves .............................................................. 90 Rubber Sheet Packing, Liberty Red .............................. 85 Rubber Splicing Compound ................................................. 242 S Salamander Steel Passenger Car Insulation ............... 92 Saturated Fabric, Asphalt ......................................................221 Savings effected by Insulating Train Pipes ............... 12 Sea Ring Packing ................................................................. 62-65 SECTIONAL PIPE INSULATIONS --Anti-Sweat Pipe ................................................................ 29 --Asbestos Fire Felt .......................................................... 24 --Asbesto-Sponge Felted ................................................ 10 --Train Pipe Insulation ..................................................... 11 --85% Magnesia ..................................................................... 17 --Improved Asbestocel, Fine Corrugated .................. 22 --List Prices ............................................................................ 32 --Weights of ............................................................................ 32 --Zero ......................................................................................... 31 Seigelite Gaskets, Flange Joint .......................................... 88 Seigelite Sheet Packing, Style No. 711 .......................... 84 Self-Healing Cement (Waterproofing) ........................222 Service Gaskets, Flange Joint ............................................ 88 Service Sheet Packing, Style No. 60 ............................... 83 Sheathing, Rosin Sized ...........................................................100 Sheet Millboard, Asbestos ................................................... 47 SHEET PACKING --Kearsarge Asbesto-Metallic ....................................... 85 --Liberty Red Rubber ............... 85 --Mobilene ....................................................................... ...... 85 --Seigelite, Style No. 711 . . .. .:................................... 84 --Service, Style No. 60 ....................................................... 83 SHEET & BLOCK. INSULATIONS --Asbestocel, Improved........... 42 . --Asbestos Fire. Felt ........... ........... 43 ` --Asbesto-Sponge Felted ... . 39 ..--35% Magnesia 40- - --Improved..Asbestocel ... 42 ' . . --List .Prices . ......................................... 49- r-^Millboard,. Asbestos 47- . --Thermo, .Fire Felf ............. ,..- 44. =>. .--Vitri.bestos .. '.V..V'v..........................46/ .' --Vitro Fire Felt.'.../'/ .. ............ .........4.5- . --Weights, and Standard Sizes ...................... ....... 49 '. Shingles, Flexstone, Asbestos, (Slate Surfaced) .... 1-79 .- Shingles, Standard and "Colorblende" (Rigid) .....167 . Siding, Asbestoside 146 Siding and Roofing, Asbestos Protected Metal ..... 159 Siding and Roofing, Transite Corrugated Asbestos .151 ' Sill Covering-......... ................................ ;100 60 (No) Service Sheet Packing ................................ 83 Sizes & Weights, Asbestos Protected Metal Roofing & Siding ..................... 163 Sizes, Weights & List Prices, Sheet & Block Insulation .................................................................................. 49 Slater's Felt, Asbestos ............................................................. 186 Slate Surfaced Asbestos Ready-to-lay Roofing, Flexstone ..................................................................................... 142 Slip Type Packing Cup Expander Ring ...................... 74 Smoke Jacks, Transite Asbestos Wood, Types G, H, J, K and L ........................................... 193-198 Special Combination Air Pump Packing ...................... 78 Specifications for application of --Asbestoside ............................................................................ 147 263 CRMC-003627 Johns-Manville Service to Railroads Page page Specifications for Application of (cont.) --Roofing, (corrugated) .................................................. 151 --Asbesto-Sponge Felted Sectional Insulation .... 13 --Smoke Jacks .................................................................. 193-198 --Asbestos Protected Metal ............................................ 163 --Ventilators ............................................................................ 199 --Barge Roofing ....................................................................ISO Transite Corrugated Asbestos Roofing & Siding ...151 --Built-up Roofing ........................................................ 131-134 Traps, Junior Steam ..................................................................113 --Built-up Brine and Ammonia Pipe Insulation .. 28 Traps, Radiator ...........................................................................114 --85% Magnesia Sectional Pipe Insulation ............. 18 Traps, Steam ..................................................................................112 --Flexstone Asbestos Ready-to-layRoofings ............ 144 Tube Plate Gaskets, Kearsarge Asbesto-Metallic ... 86 --Flexstone Asbestos Shingles .............................. 181-182 --Kearsarge Jointless ........................................................... 86 --Improved Asbestocel SectionalPipeInsulation 23 Tubing, Asbestos Braided .................................................... 242 --Industrial Flooring ..................................................215-216 Tubular Gasketing, Kearsarge Asbesto-Metallic .... 87 --Insulating Cold Water Pipes ...................................... 30 Twisted Asbestos Rope Packing ....................................... 73 --Locomotive Cab Roofing ..............................................149 --Sea Ring Packing ............................................................ 65 --Standard and "Colorblende" Asbestos Shingles .......................................... 177-178 --Transite Corrugated Asbestos Roofing & Siding 155 --Underground System of Insulation ........................ 37 Spiral Combination Pipe Insulation ............................... 26 Splicing Compound, Rubber ........... 242 Stacks and Caps, Transite Asbestos Wood.................199 Standard & "Colorblende" Asbestos Shingles (Rigid), 167 u Underfloor Duct System, Orangeburg ........................... 236 Underground System of Insulation ................................... 33 Underwriters Approval of Roofings ................................ 120 Uninsulated Hot Surfaces, Lossesfrom ......................... 253 Union Washers .............................................................................. 90 Universal Piston Packing ....................................................... 69 --Combination Steam Hammer Packing .................... 70 --Rod & Plunger Packing ................................................. 72 Standard Flanged Fittings, Radiation area of .........255 V Standard Hair Felt ....................................................................100 Valves, Rubber Pump ................................................................ 90 Steam Hammer Packing, Universal Combination ... 70 Ventilators, Transite Asbestos Wood .............................. 199 Steam Leakage, Losses due to ...........................................252 Vitribestos Sheets and Blocks ............................................ - 46 Steam Pipe Insulation, Minimum Thicknesses of .. .253 Vitro Fire Felt Sheets and Blocks.......................... 45 Steam Traps ................................... HO Volume of Water at VariousPressures ............................253 Steam Tables (Marks') .................................................. 249-252 Volume Meter ........................................................ Steel Passenger Car Insulation- 92 Steel and Wrought Iron Pipe, Data on ....................254 Stone Backing, Cut ...................................................... 223 Story of Asbestos ......... ..:................................ 6 w Walls'and Ceilings,'Transite Asbestos Wood, Details of................ . : , ...............191-192 Stove Lining, Phoenix Asbestos ................ .................... 60 . . Wall Coating,'. Boiler, Aertite ........................................ ..;. 59 Strip ShingleSj Flexstone Asbestos ............... 179-180 ; Wall,1 Monolithic Baffle .........................................,58. ... Success :Fire;.Extinguisher,./Automatic Type .......245- Wall Siding, As'oestosid'e Y...............,........................... .. 146, v Success pire. Extinguisher; Non-Freezing: .................. 245 ... Washers, Union. ........................................ 90. ' Superb-Refractory-Cements,-Nos. 33 and 35 ............... 56' Water Gauge Gaskets ........... ......................... ........................ 89 . Waterproof: Coating,- Liquid .....................................: 223 Table of Data.on Wrought Iron: and Steel Pipe ....254. --Decimal--Equivalents .........................................................256 --Fahrenheit :ahd': Centigrade Conversions ;............258 . --^Metric Conversion . ..258 --Losses dueFoYSteam Leakage ............ 252 . . --From-.Bare; Surfaces .Vr............................ .. . 249 --Steam. .'-v'. .... . . . . : .249 Tank Car Insulation: ..... :........... 101 Tape, Friction :vv\Y.'.....':.................................................. 241 .Tape, Kearsarge Asbesto-Metallic Gasketing ............. 87 Technical Data, Refractory Cements ............................... 57 Temperature Conversion Tables. ........................ ...258 Test on Roofing,. Underwriters ........................................... 120 Thermo Fire Felt Sheets and Blocks ............................. 44 --Efficiencies .of .................. 48 --List Prices ............................................................................ 49 Thickness of Steam Pipe Insulation, Minimum ..........253 Third Rail Covering ............................................................... 244 Throttle Packing, Kearsarge ...................... 81 Top Head and Bottom Head Gaskets for Air Pumps 90 Train Pipe Insulation, Asbesto-Sponge Felted.......... 11 Transite Asbestos Wood (flat) --(Building Purposes) ......................................................... 188 --(Electrical Purposes) .................................................... 230 --Caps and Stacks .................................................................. 199 , Waterproofing. :- --Cement, -Asphalt'. -........................... 221 ' --Self-Healing .Y. .. ..................'..............222. . --Felt;. Asbestos . ...221 . . ..Water Volume at Various Pressures ................ 253 ..Weights Corrugated Asbestos Roofing & Siding; . Asbestos -Protected Metal :... . ................................. 163 .Weights and List Prices --Ebony-Asbestos Wood . ...........................................229 --Transite Asbestos Wood .......................................... ..230 --Sheet '& Block Insulation. ........................................... .. 49 --Sectional Pipe Insulation ............................................. 32 Westinghouse Air Pumps, Packing for ........................ 80 White Top Asbestos Ready-to-lay Roofing ............... 143 Wick and Rope Packing, Asbestos .................................... 73 Wood, Ebony Asbestos .........................................................228 Wood, Transite Asbestos (fiat) ......................................... 188 --for Electrical purposes .................................................. 230 --Smoke Jacks ................................................................ 193-198 --Stacks and Caps .................................................................. 199 --Ventilators ..............................................................................199 Wool Felt Sectional Pipe Insulation ............................... 31 Wrought Iron and Steel Pipe, Data on............................254 z Zero Sectional Pipe Insulation ............................................. 31 264 CRMC-003628 116-