Document NEZVMegMgd7b01wez5Lpz7RDQ
Johns-Manville Service to Railroads
Asbestos Roofings, Packings and Insulations:
Steam
and
Electrical
Railroad Supplies
PLAINTIFFS i EXHIBIT
P 3^?2<,QQ.
Akron Albany Atlanta Baltimore Birmingham Boston Buffalo Canton Chicago Cincinnati Cleveland
Manville
Incorporated
Executive Offices: New York
PLAINTIFFS EXHIBIT
wu pi snq
Columbus Dallas Dayton
Denver Detroit Duluth
Erie Grand Rapids Houston
Indianapolis Kansas City
Los Angeles Louisville Memphis
Milwaukee Minneapolis Nashville Newark New Orleans Omaha Philadelphia Pittsburgh
Portland (Me.)
Providence (R. I.) Rochester St. Louis St. Paul Salt Lake City San Diego San Francisco Seattle
Syracuse Tacoma
Tulsa Washington Wilkes-Barre Worcester (Mass.) Youngstown
Havana, Cuba
Montreal
Canadian Johns-Manville Co., Limited
Ottawa
Toronto
Vancouver
Printed in V. S. A.
Winnipeg
CRMC-003366
Johns-Manville Factories and Mines
CRMC-003367
A Few of the Main Johns -Manville Branches
CRMC-003368
Johns-Manville Service to Railroads
Johns-Manville Service to Railroads
A Contribution to America's Progress
stablished in 1858, johns-Man-
E, ville has achieved and maintained supremacy in its field because, through the scientific development of As
does it fit the needs of this new world of steam, electricity and blazing furnaces, that it seems to have been almost pur posely designed.
bestos, it has served the industrial world and its life-giving arteries of trade, the railroads, as has no other institution in America.
More than half a century has been de voted by Johns-Manville to making As bestos fill these needs efficiently and econ omically; and this catalog is in reality a
More than a century back, the power of record of accomplishment. We are pre steam was discovered. Coal then as pared to furnish anything made of Asbes
sumed new duties as steam fuel. Later tos, Magnesia and related products, as
the development of electrical power gave well as many other special articles for rail
us another of. Nature's forces to use, and road and general industrial use.:
in our use of steam, electricity add the in
Johns-Manville Service: does not. stop,
tense fires required by mdfistty^ wc. were constantly faced with the;-phpbie^'of:vcbn-.
-trolling the tremendous^ to yy.'.lisd
here. :At each^to fully ofgahized Gonst^
evoked. Asbestos has gtPtiy;;assisted: in , for the application of hUtlmaterials; This
the solution ofHhis problemvf trough; in-' department includes- a
sulations; packings; brake linings, toofings enced and competent engineers: and skilled
--in innumerable ways* it enables us to - mechanics, thoroughly familiar with the'
bend to man's service forces which - were application of our products.
once- his, master. ::
^ Throughout the bo'ok will be found val
Asbestos stands, unique---a world-old uable technic^}.: ffifoim^iom .relating^; to rock which is immune to* the action of ' our various hn|s| anfi;ifi::j:h4jt^.eiidixfis.
. heatj water, weather and %ear^a fibrous. a collection of tables fif engipeeriiig data
mineral which can ,be spun, woven, felted . which makes this: volume;`not-only a cata
or molded into useful \fofm.\ ,So -closely log but ah.engineer's.handbook ^w^
5
CRMC-003369
Johns-Manville Service to Railroads
The Story of Asbestos
Piece of crude asbestos, just as it comes
from the mine, split to show the mineral fibres.
ILLIONS of years ago this' earth' brittle, heavy as rock in its crude state,
M; went through untold ages of flame, yet as light as thistledown when treated ; slowly; forrni-ng4 a-; marvelous' miri-mechanically. Through::all:the countless yeral---as. heavy and Ihehse hs marblea,geyse, tduring which the- hardest rocks sur
'. literally a nugget of'silky fibre--ASBES rounding] it have been reduced, this min-
TOS.
eralogickl :mystery hab remained intact;
A Asbestos Is one of the most remarkable : having; successfully resisted the assaults
substances found in nature. Its unique of fiire;!acids arid time, /
r-
properties are unparalleled.: ' -Wood burns Asbestos is found in various parts Of the
--Asb:estds;Is' unch;mge&bb^
? wotld, but;pf unusually pure quality in our
tenipefatures: of 1500 E;; " Stprie diS'im exterisive^riiines in thp: Province of Quebec,
tegrafes^trAsbestps; defies Erosion. Steel Canada 'arid innChrysplile,
rusts--Asbestos is immune;
Asbestos is qiiarriedTri much the sarne
It is b -peculiar species of the horn manner as stone; and, when it comes from
blende family of minerals. Its composi the mine, looks like ordinary rock except
tion is chiefly silica, magnesia and a that it has: a gray or dark green surface.
small quantity of alumina, ferrous oxide After being mechanically treated the re
and water. The fibres formed by this markable mineral fibres extracted from
chemical combination are perfectly smooth the rock can be spun, woven and otherwise
and non-tubular and in these respects are manufactured into many useful articles.
different from all other known fibres.
For centuries Asbestos was but a curi
Paradoxically, it is the link which com osity--the mystic mineral, the paradox of
pletes the chain between the vegetable ages. But today it is a recognized neces
and the mineral kingdoms; it is in fact sity, developed by the efforts, the courage
a mineralogical vegetable possessing the and the resources of those manufacturers
curious properties found in both, for it is who, from the beginning, have recognized
at once fibrous and crystalline, elastic and its possibilities.
6
CRMC-003370
Johns - Manville Insulating Materials
7
CRMC-003371
Johns-Manville Service to Railroads
Johns -Manville Insulating Materials
ORE horsepower from the world's
M coal pile is one of the big problems of industry that touches us all. The economy with which coal is burned is as important in regulating the price of life's necessities as the cost of raw materials or the price of labor.
But if saving coal means losing power the ultimate economy is doubtful. Hence, "More power delivered per pound of coal" is the aim of all industry as it strives for economy. "More heat delivered per ton of coal" is the aim of every fuel-user.
perfecting of these heat insulations and their application to thousands of power plants, is saving power by saving fuel-- millions of dollars worth annually; nor does this include countless other installa tions on the heating systems of offices and buildings generally, where coal is burned for human comfort.
Thirty years' specialization, directed by the highest engineering talent, has enabled Johns-Manville to develop and produce insulations of exceptional efficiency and durability under every service condition.
. It is the growth of production---with its
Asbesto-Sponge Felted, for example--
; correspondingly greater needs-^that. has a remarkable: felt;: which combines the
made one of; the most important results of : "dead-air cell" insulation of .sponge with
the development. q.;;Asbestos b:^. Johns- the endurance of :asbestos-4is;rahked first
. Manville, the saving, of heat.' through in in efficiency by independent investigators.
sulation. Johns-Manville has developed materials,built yOh: asbestos as a base, that retard the escape of heat from boilers,
Or 85<J0 Magnesiar^--or Improved Asbestocel, Zero, Anti-Sweat, or Brine; and Am-
furnaces, pipes anbfiues--heat, energy that : monia Insulatiphs---whateyer your needs,
would otherwise be wasted,
5:
you can meet them efficiently with one pf
the Johns-Manville Insulations - described
Johns-Manville: Insulation Service, the on the following pages.
8 CRMC-003372
Johns -Manville Service to Railroads
Insulation
i HE real object of insulation is to pre An insulation that would allow no flow
Tvent the flow of heat to the outside of heat through it would be 100 per cent, surrounding air from a boiler, appa efficient. ratus or pipe in which it may be generated,
stored or conveyed, or to prevent the flow Material that offered no resistance to
of heat from the outside to fluids or solids the flow of heat would have an efficiency
which should be kept cool or at low tem of 0 (zero).
peratures.
The unit of heat is a B.t.u. (British thermal unit)--just as a gallon is a unit of liquid measure, a foot a unit of linear measure or an ampere a unit of electrical current flow.
The two examples above are the two ex tremes that do not exist, but the 100 per cent efficient insulation is nearly obtained by the application of any one of several Johns-Manville forms of insulation.
The flow of heat from the fluid in a bare
, or insulated; pipe; to . the; outside surround
ing air-is measured by the number of heat
:uhits, :that"fc
walls of; the.
.pipei.;or'insulation,mbhoth, :and: is usually
The efficiency of an insulating material is expressed by a percentage which is the , per cent saving which - would be; effected. by insulating a pipe with that material Over what would heJost if the pipe were
expressed in the number of B .t.u; that flow left bare or uninsulated.
1
through an area of one square foot in one
hour---(B.t.u;. per square: foot pet hour).
The efficiency, per .cent is obtained ; by
subtracting the heat loss of the insulated'/
The rate of flow through .a certain.thick- pipe from the heat loss -df the; uninsulated
ness and at a certain; difference in temper or bare pipe and dividing the difference by
ature determines. the conductivity of the: the heat loss from the bate pipe. See How material through which the heat flows, A to Use Efficiency Tables on page 248 of smaller number of heat units flow; through Appendix. a given thickness of a material with a low
conductivity than through one with a high
On the following pages are tables and
conductivity.
technical data pertaining to Johns-Man
The relative efficiencies of various in ville Insulations, and on page 253 of Ap sulating materials may be appreciated by pendix is table showing thickness of steam
comparing their conductivities under sim pipe insulation recommended for various
ilar conditions.
temperatures and pressures.
9
CRMC-003373
Johns-Martville Service to Railroads
Johns-Manville Asbesto - Sponge Felted Sectional Pipe Insulation
The most durable, efficient and adaptable in sulation known for insulating pipes conveying steam at high pressures and temperatures.
QHNS-MANVILLE Asbesto - Sponge necessary it can be removed from the pipes
J Felted Insulation is made of layers of and replaced . without.;; injury,'.: : thin felt, composed of asbestos.;fibre.-and ; . Expansion and con.traction: of pipes will papticies pf finely ground, spopgy material not wear, away; or harm the inside, of Ast
- forming an extremely cellular felt, built besto-Sponge Felted Insulation. Because
: up like a book in laminated form, thereby of its durability^ adaptability and' perma
. ' confining: a: large.Volume. of minute dead nent efficiency it provides exceptional eco-
:S.ir cells in thedelt and. between ;the layers. ; ;nomy. -. Sections .arelcut entirely through
Johns-Manville Asbesto-Sponge Felted on one side only/ which is a distinct ad
. ; : Insulation possesses hot only very -high vantage From ah"ins
; initial efficiehcy as- sh6wn on thefollow-: Johns-Manville rAabesto-Sponge Felted
ing -pages* but permanent efficiency year Sectional Pipe. Insulation is- furnished in
after year because of: its" extremely dur thicknesses;.from,^"-;tQ 3",'in 3-foot sec
able construction. Because of its construction, and unlike
insulations of the molded type, Johns-
tions with canvas jacket and brass-lac quered bands, to fit standard pipe sizes. Specifications for insulating with JohnsManville Asbesto-Sponge Felted Insula
Manville Asbesto-Sponge Felted is tough, tion will be found on page 13.
flexible and practically indestructible.
Also furnished in sheets and blocks for
Pipe vibration, and the general wear and boilers, flues and other large regular sur
tear to which insulation is subjected, will faces, Sheets 24" x 36" and blocks 6" x
not pulverize Sponge Felted Insulation 36", in thicknesses from
to 4".
or break it away from the pipe. Even if For descriptive data on this insulation subjected to excessive moisture or satu in sheet and block form, see page 39.
rated with water it will dry out and
See approximate weights and price list
regain its initial efficiency. Whenever on page 32.
10
CRMC-003374
Johns-Manville Service to Railroads
Johns-Manville Asbesto-Sponge Felted Train Pipe Insulation
WEATHERPROOF ASBESTOS. FELT JACKET FOR. TRAIN PIPE INSOLATION
................ ...........................Ouant.tv of Weatherproof
. Size of,.-.-
-Asbestos :Felt required per
Pipe .,
100 lin:- it. of pipe, with stan-
Lin. ft. *
'A" .......................................... ... 42
. Va"
...............
...45
I" : ... .
47
iVa" ..................................
... 50
i Vi" .......................................... ... 53
.2" .......................................... . . . 58
VA" 3"
354"
4"
.......................................... . . . ....................................... . . . .......................................... . ..
........................................ . . .
64 70 75 81
w.......................................... ... 86
5" ...........................................
6" .......................................... . .. 104
r .......................................... . . . 115
3" .......................................... . . .125
9" .......................................... ...140
10"
.......................................... ...149
Sid. 32" wide.
. >
Squares
1.04 1.11
1.15 1.23 1.31 1.43 1.58 1.73 1.88 2-00 2.12 2.30 2.57 2 84 3.11 3.46 3.68
-Pounds of. Wo: 1X5 (B. & S.) Copper Wire per 100 - - Jin. ft.
1.70 1.85 '.2.00 ' 2.13 2.23 2.42 2.64 2,90 3.13 3.34 3.56 3.80 4.24 4.70 5.12 5.54 6.02
11
CRMC-003375
Johns-Manville Service to Railroads
Comparative Efficiencies of 1-inch Asbesto-Sponge Felted
and s/8-inch Indented Insulations on 10-Car Train
Example showing saving effected by using insulation of correct thickness and high efficiency on train pipes
RAIN pipes are frequently insulated
Twith an insufficient thickness of insulation and furthermore the insula-
The following data show the economy of using the correct thickness of highly efficient insulation. The slightly greater
tion used is often not of the most efficient first cost is repaid many times over by the
type.
saving effected.
Number of Cars--10 Length of Pipe Per Car--70 ft. of 2" pipe; 20 ft.
of 1" pipe Steam Pressure in Pipe--40 lbs. per sq. in. (gauge)
Steam Temperature in Pipe 287 F. Average Air Temperature surrounding Pipes--30 F. Temperature Difference--257 F. Efficiencies in Still Air at 257s Temperature Dif
ference:
1'' Pipe 2" Pipe
Standard Thick
fg" Thick
Asbesto-Sponge Felted
Indented
. ... 81.48% ..................................................... 65.78%
.... 84.55% ...................................................... 71.06%
Heating Value of Coal--10,000 B.t.u. available per pound. (This is very conservative as it is equivalent to a boiler efficiency of about 70% and coal with 14,000 B.t.u. per lb. Both the boiler efficiency and the heat ing value of coal are high and with lower boiler efficiency or lower heating value, the pounds of coal saved, would be even greater than given in the table.)
Ajr Velocity*., ,.. Miles per' hr;,
Losses
'V : B.t.u/;Per Linear Ft. Per Hour . , . 'insulated with:-;1
/Standard, T-hick Aibestd-Sponge Felted1
. ... ..Thick '. ' Indented
..Additional. Saving by. Asbesto-Sdonge Felted, as compared ..with Indented.
B:t.u. ..Per; Linear;; . . Saving 'Per Hour :
Ft. Per Hour .
on 10-Car Train
'
. 25
-so
. . Pipe Size Xv'T/x,;:/ .2
Pipe Size
. 1"
2":
' Pipe Size. ' v ;
';,r '2X
. B.t.u. Lbs. Coal'
.X ... / 49;7 r-. .7-4-1
91.8' . 138.9 . 42.1 ' - 64-.8'.' / : `"53,78d . 5.38. -
5,9.6 : 89.4 : ' 124.0 . 193.5' - 64.4; 104.1, . 85,690 : 8.57 .
60.0 . - 90.0
. 126.2 19.8.3
66.2 : 108.3
89,050 8.90 ;
Air.Velocity .may; be.,,due. ejtlje'r'.fo wind, when train,;is standing,..:pr'to motion.;of. train,';.with reference to
surrbu.ndirig..atr; ' ' r- :
:V.
Note the large' saving pri; a 10-car train insulated.... with .Standard Thick JohnsManville Asbesto-Sponge Felted as com pared with %" Indented Pipe Insulation. This saving amounts to 53,780 B.t.u. each hour or 5.38 lbs. of coal in still air and is increased to 85,690 or 8.57 lbs. of coal each hour that the air velocity is 25 miles per hour.
From the above table the value of the saving may readily be computed for any number of hours operation per year and any price of coal. For example, assuming 4000 hours operation per year with an average air velocity of 25 miles per hour,
the saving would be equivalent to
85,690X4000 _ _
,,V
io.oooxSooo^7-14 tons of coal
which at $5.00 a ton is equivalent to $85.70. Based on a list price of insulation of
$306.00 for the 10-car train and about 15% of list difference between Asbesto-Sponge Felted and Indented the difference in cost amounts to $45.90. This means that the extra cost of the Asbesto-Sponge Felted will be paid for in 3 months of the first heating season and that each year there after the Asbesto-Sponge Felted gives a clear saving of $85.70 more than the In dented.
12
CRMC-003376
Johns-Manville Service to Railroads
Standard Specifications for Insulating Steam Pipes with Johns-Manville Asbesto-Sponge Felted Sectional Insulation
All live steam and feed water piping shall be insu- Sectional Insulation applied in different thicklated with Johns-Manville Asbesto-Sponge Felted nesses for different classes of piping as follows:
Steam Pressure or Condition
Steam Temperature
Thickness of Insulation
Pipes larger
Pipes
Pipes
than 4"
2" to 4"
y3" toV/3
SUPERHEATED STEAM PIPING
High Superheat ........................................................................ 600 to 700 F. Superheat .....................................................................................500 to 600 F.
3"* 254"*
3" 254 "
2" 2"
* In addition to sectional insulation, Johns-Manville Insulating Cement l/3" thick is to be applied over the Asbesto-Sponge Felted Insulation on pipes larger than 4"
HIGH PRESSURE (OR LOW SUPERHEAT) STEAM PIPING
Higher than 200 lbs. (or low superheat).......................388 to 500 F. 1Q0 to 200 lbs. ........ ........................ .................................... .. .338 to 388 F,
254" 2"
2" 154"
154" 1"
MEDIUM PRESSURE STEAM PIPING
25 to 100 lbs................................................... ............................. ;267 to 338 F.
. 1^4"
' . ' 154"
1"
; : LOW PRESSURE STEAM AND FEED WATER PIPING
Oto 25 lbs. ................. .................. .......................................... 212 to 267 F.
'Feed .Water' Piping-' . .W.-v.
...V........ ...
''I" ' i"-
1" . i"-
1" !; -1"
Superheated Steam Piping
The insulation for superheated steam piping shall be applied in at least, two layefs .to'make up the. total thickness required,; as specified' above. The first layer shall be applied to the piping with out canvas jacket and be secured in place: with annealed iron, wire wrapped. around, its circum ference and fastened on at intervals of 6". [All joints in the insulation.shall be sealed during ap plication with Johns-Manville Insulating Cement. These joints shall be filled with cement as the sections are applied and the sections shall then be tightly drawn together by means of the wires referred to above. Any cement protruding from the joints shall be plastered back with a trowel.]
The second or succeeding layers shall be ap plied as described above and shall be so placed
. that all joints in adjacent, layers are broken or
.staggered. Canvas jacket js -to be ofnitted, except
on outer layer of. insulation on: .pipes., 4" and
smaller. . .
:;;V
On all pipes larger than. 4" after the sectional insulation has been applied as specified above there shall be applied over this a finish of JohnsManville Insulating Cement J4" thick applied in, two coats and troweled to a smooth and uniform surface.
Where the cement finish is not used it is more than ever essential that all joints be well sealed as the purpose of this cement finish is to make certain that there are no open joints through which heat can be lost.
High Pressure Saturated Steam Piping (or Low Superheat)
The insulation for high pressure steam piping, where thickness is 2" or more, shall be applied in two layers to make up the total thickness as given above and, where thickness is 1y2" or less, in a single layer of the required thickness. The can
vas jacket shall be omitted from the first layer where insulation is applied in two layers. All joints shall be cemented and the insulation shall be secured in place with wire in the same manner as specified for superheated steam piping.
13 CRMC-003377
Johns-Manville Service to Railroads
Low Pressure Steam and Feed Water Lines
The low pressure steam and. feed water pip- This insulation shall be applied with joints ing shall be insulated with a single layer of closely drawn together and canvas jacket pasted the required thickness, as given hereinbefore, down.
Fittings and Flanges
The bodies of all flanged fittings and all screwed fittings, including valves of the larger
sizes (4" and over) shall be insulated with block and cement insulation of the same material and thickness as is used on the pipe lines on which they occur. The block insulation shall be securely wired in place with annealed iron wire and all
joints shall be filled with insulating cement. The insulation shall be finished with Johns-Manville Insulating Cement troweled to a smooth and uniform surface.
All fittings smaller than. 4" in size shall be insulated with Johns-Manville Insulating Cement applied in layers, each about ^4" thick, to the same total thickness as the adjacent pipe insulation. Each layer of this cement is to be allowed to dry before the. next layer is applied and each layer, except the last,, is to be applied with a , rough surface. The last layer is to be troweled to a smooth and uniform surface.- .
Flanges may be insulated with either a perman-
ent or removable and replaceable type of insulation.
The permanent type of insulation shall consist of a built-up block and cement insulation constructed of the same material and of the same thickness as the adjacent pipe insulation and applied as described above for fittings,
The removable and replaceable type of flange cover shall be of the same thickness as the adjacent pipe insulation and shall be constructed as follows:
Use suitable size and length of Johns-Manville Asbesto-Sponge Felted Sectional Insulation to completely encircle flange and overlap the adjoining pipe insulation at least 2" on each side of the flange. Secure this flange insulation, with wire and fill the space between the pipe and flange insu'ation with Johns-Manville Insulating Cement and apply a thin coat of Johns-Manville Insulating Cement over the entire surface of the : flange cover.
Finish of Insulation
... After .all. insulation, has been., completely, ap are-to be located where least visible.
plied and all cement surfaces troweled to a This canvas jacket shall be painted with first
smooth.and uniform finish, apply over all insula-; a coat of sizing and then with two coats of fire
tion on piping and,fittings an additional jacket of. proof paint or lead and oil paint of color desired.
8 oz; canvas. This jacket is. to be .sewed on dyer, :(Where re-canvasing is not desired or is con
a lining of heavy, rosin-sized paper,, and all, seams sidered unnecessary, see Note B.)
\ \':V
Weatherproof jacket
If piping is located out of doors and is expbsed . ends twisted tightly together. . These wire rings to the weather the additional protectiomOf 8 oz. are to be placed on A" centers. The jacket is to canvas and paint may be omitted and in its place lap at least 3" in all directions and all horizontal the insulation shall be protected with a Johns- laps are to be located on the side of the insulation , Manville Asbestos Weatherproof: Pipe Insulation and turned downward in order to shed, all water jacket, secured with rings formed of No. 16 from the surface. Copper Wire wound once around the jacket and
NOTE "A": Johns-Manville maintains an Engineering Department at each of its Branches, which will on request recommend proper thick nesses of insulation for various special conditions.
NOTE "B": The light canvas jacket regularly furnished with the insulation shall be neatly pasted down over all laps. The pipe insulation shall be additionally secured in place with brass lacquered bands furnished with the material,
p'aced at suitable intervals at least two bands per section of pipe insulation.
All cement surfaces shall be finally finished with a jacket of light canvas neatly and securely pasted on.
NOTE "C": When extremely low tempera tures are encountered out of doors special recom mendations will be given by any Johns-Manville Branch Engineering Department.
14
CRMC-003378
Johns'Mairville Service to Railroads
What Insulation Efficiency Means
HE efficiency of an insulating mate
Trial is expressed by a percentage, which is the per cent of heat saved
ence in temperature between steam in the pipe and air surrounding the pipe, as well as according to thickness of insulation.
by using the insulation as compared what would be lost if no insulation were used and the pipe left bare or uninsulated.
toComplete of efficiency
information tables with
regarding the use examples to illus
The efficiencies of all insulations vary trate will be found on page 248.
according to the size of pipe to which they For table showing total heat loss from
are applied and according to the differ bare pipes, see page 249.
EFFICIENCIES OF STANDARD THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE
Pipe Size.
Temperature Difference Between Steam in Pipe and Air Surrounding Pipe
Inches
,-.0
100
150
200
<
250
300
360
Per. Cent.. Efficiencies
oo
450
500
54...-:.............. .. Ya.......................
I ........................
............... ...............
............
68.5% . 71.2%
71.9
. 74.3
74.3 ' ,. 76.5 ;.
73.3%
75.5 %
76.2 . 78.1 '
78.2 ", ; ,79.9
77.1% 79.6 81.3
78.7% 81.0 .82.6
80.4% 82.6 84.0 .
81.9% .83.8 ; 85.2'
83.1%
.85 0 . '86.2
84.5% 86.2 -87.4 -
P'.':. . 11;. , 2
.................. ..........:. .
75.7 77.0
.. .......... L : 78.6.
' 77.7 .' 79.5.. !' 81.0
82.3-
79.0 . . 80,5'. . 82.0 ; ' 83.2
.80,4
" 81.9
83.3 .
.84.4.
83.5
84.4 , 85.5
84.9 ' 86.0:
86.9
85.7r . 86.7.V
87.6
86.7
- 87.6
, .88.5 ; .
88.0 88.8 89.3
.......
...... 79.8
3 ........................
............ : ' 80.6 '
Si'...:..........
.......... 81.2
V" .'.............81.8 'J
........:.vL.. ........82.1
, 5" , ........ ''82.-3
81.5 82.2 .' 82.8
82.9
.. 84.3
8S.6 ; ' 64.9 -
84.1 .
85.4 ;
I-83;8 . 84.5 ' 85.8 '
: 83.6 ' . 84.8 . : 86.0 ,
; 83.8 1 ' 85.0
56.2
85.3 85.9 86.3
86.7 87 Q.. 87.1 ,
86.3 86.8 . . ,87.3
.87.6 87 9
88.0
87.5 87.9
83.4. 88.8
89.2 89.6
90.0 90.3
88.3
89.2 '
89.9
90.6 :
88.7
. 89.5 f. .. 90.2 '. . 90.0 .
889
89.7
90 4 '
89.0 , . . : 89.8 , ' ; . 80.5 ...
91.1 91.2
:3 V............
. ...........
82.7 ' 84.2 ;
7
. ........ 83.0.
; 84.5 '
3 ' '.i'-;-....
83.4 ; !- ; 84-8
109'
'. ..
. . .:83.5 ___ ............. . 83.8
84.01..' . ;85.i\ .
85.4 : 86.6 . 85.9", .
86.5 86.8 : 87.0
86.6' : 87.2 86.2; ; 87;3.
87.487.6.' 87.9
88.0 88.2, V
88.3
: 88.5 - 88:7
8:8 8
; 89.0
89.3 . 89.5 ; 89.7
69.8.'
89.9 '
- 90.1 ' 90.7
96.2 W : - 90.9
'90.4
' 9i:i ,
'. 80.5 \ V 91.2' .; '90.6: ( v , 91.3 -.
: 91.4 91;6
91.7
.91.8 91.9,-.
EFFICIENCIES OF 154'" THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE
Pipe Sizes Inches
60
Ya............................... 1 ............................... ...............
............................... .............. M4............................... 2 ............................... ..............
*14............................... 3 ............................... ............ 3'A............................... 4 ............................... ............... 4 ^............................... ............... 5 ............................... ..............
6 ............................... 7 ............................... ............... 8 ............................... ...............
9 ............................... ............... 10 ............................... ...............
76.1 77.8
81.0
03.0
84.2 84.6 85.0
e* 9 86.2 86.4 86.6
... Temperature Difference Between Steam in Pipe and Air Surrounding,-Pipe
`100 ;
150
200
250- 1 '300'
360
400 450
72.9% 75.9 78.1
79.7 80.7 82.7
83.7 84.5 85.0
85.5 85.9 86.3
86.7 87 1 87.5
87.7 87.8
75.0% 77.7 79.6
81 2 82.3 64.0
85.1 85 7 86.2
86.7 87.1 87.4
87.8 88.1 88.4
88.6
88.8
76.8% 79.4
61.3
82.5 83.5 85.2
86.1 83 a 87.2
87.7 88.0 88.3
88.6 89.0 89.1
80.3 89.6
Per Cent. Efficiencies
78.4% 83 9
82.7
83.0% 82.4 84.1
81.5% 83 5
85.1
83.8 84.7
86.2
85.1 86.Q 87.2
86 1 86 9 88.1
87 0 87.7
66.1
88 1 88 7 89.1
88 8 89.4 89.8
83 5 88.8 89.1
89.5 89.8 90.0
90.1 90.4 90.6
89.4 89.6 93.0
90.3 90.6 90.8
90 9 91.2 91.4
00.1 93.3
90.9 91.0
91.6 91. G
82.9% 84.9 86.3
87.2 88.0 89.1
89.8 90.3 90.6
91.0 91.2 91.4
91.7 91.9 92.1
92.2 92.3
84.2% 86.0 87.3
88.2
88 8 89.9
90 5 91.0 91.3
91.6 91 8 92.0
92.2 92.6 92.7
92.6 92.9
600'
85.2% 87.0 88.1
690 89.9 90.6
91.1 91.6 91.9
92.1 92.3 92.5 92.7 92.9 93.1 93.2 93.4
15
CRMC-003379
Johns-Manville Service to Railroads
EFFICIENCIES OF 2" THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE
Pipe Size, Inches
50
54............................... .............. yA............................... .............. l ............................... ..............
VA............................... .............. 154............................... .............. 2 ............................... ..............
2 54 ............................. .............. S ............................... .............. 854............................... ..............
4 ............................... .............. 4>4 ........................ .............. G ............................... ..............
6 ............................... .............. 7 ............................... .............. B ............................... ..............
0 ............................... .............. 10 ............................... ..............
73.2% 76.5 78.8
80.5 81.7 US.6
84.3 85.6 86.2
86.7 87.1 87.5
88.0 88.4 88.6
88.0 89.1
Temperature Difference Between Steam in Pipe an d Air Surrounding: Pipe
100
150
200
250
300
850
400
450
Per Cent. Efficiencies
75.6% 78.6 80.7
82.0 83.4 85.1
86.1 86.6 87.4
87.9 88.3 88.6
89.1 89 4 89.6
89.9 90.1
77.5 % 80.3 82.2
83.6 84.7 86.2
87.2 87.9 88.4
68.8 89.2 89.5
89 9 ' 90.2 90.4
90.6 90.8
79.2% 81.8 83.6
84.9 85.9 87.2
88.2 88.8 89.3
89.7 90.0 90.3
90.7 91.0 91.2
91.4 91.5
80.7% 83.1 84.8
86 0 86.9 88.1
69.0 89.6 90.1
90.5 90.7 91.0
91.8 91.6 91.8
92.0 92.2
82.0 % 84.2 85.8
87.1 87.8 89.0
89 7 90.8 90.8
91.1 91.3 91.6
91.9 92.2 92.4
92 5 92.7
83.5% 85.5 87.0
88.0 88.7 89.9
90.5 91.1 91.5
91.8 92.1 92.3
92.6 92.8 93.0
93.1 93.3
84.6% 86.5 87.8
88.8 89.5 9D.6
91.2 91.7 92.1
92.4 92.6 92.8
93.1 93.3 93.4
93.6 93.7
86.1% 87.8 89.0
89.8 90.4 91.4
92.0 92.5 92.8
93.1 93.3 93.5
98.8 94.0 94.1
94.2 94.3
500
87.4: 88.8 90.0 908 91.2 92.1 92.7 93.2 93.5
93.7 03.9 94.1 94.8 94.5 94.6 94 7 94.8
EFFICIENCIES OF 2^" THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPE
Pipe Size, Inches
50 -
Temperature Difference Between Steam in Pipe and Air Surrounding Pipe
100
150
200
250
300
350
Per Cent. Efficiencies
400
450
t/j. . ...................75.0%
y4:.............
.................. 78.2
1 ........ ..............80.5
77.3% . 78.9%
80.0
81.6
82.2. : .. 83.5
VA-':.'............. ................... VA ................ 2 . . :............ ..............
82.2 ` 83.4 '
' 85.2
83.8 . 84.9
84.9 -
86.0
86.5 : .. 87:5 > .
nyt.. ............... . .............. ' 86.3 3 ..........: .;............' 87.1. V; VA'.:............ ............-87.8
87.5
88.3 : 86.9 :
;. 88.4 :
: 89.1 '. 89.7.:.-:
.:..........\ 88.3 ''
!4 y:.;..........
' 6
___ ............
89.0 '
89.3 /
90.1 -
89.7 ` . 90.4 -
90.0 ' 90.7 :
6 'v.\. 8
___ : 89.5
V................ ' 89.9' ............ 90.1'-'
' 90 4 '
90.8 ' .91.0
91.1 ' 91.4..
91.6
91.2 > -91.8 .
10
.. .........
: 93.5 . .91.4
92.0-
80.7% 83.2 85.0
86;2 87.2 68.6
89,4 . 90.1 : 90.6
90.9 91.2 91.5
91.9 92.2 92.4 92.5 . 92.7
82.1% 84.4 86.0
87.2 88.1 89.4
90.2 90.3 91.2
91.6 91.9 92.0
92.0 92.7 92.9 :
93.1 . 93.2 '
83.7% 85.7 87.2
88.3 89.1 90.3
91.0 91.6 92i0
92.3 92.6 .92.8
93.1 93.4 : 93.5
93.7 : 93.8
84.8 a 86.7
88.1 '
85.9% . 87.7
89.0 >
69.1 89.9 . 91.0
90.0 '
90.6 91.7 .
91.7 92.2
92.6
92.3 . 92.7 . .-. 93.1 .
92.9 93 1 93.3
93.4
93.6 - 98.6 '
93;6.
93.8. 94.0
94.1 : 94.3 '
94.4
94.1
94.6 ...
.,,94.2' "" 94 7 ;
87.0%. 88.5 89.7
90.6 91.2 92.2
92 8 93.2 93.5
93.8 94.0 . 94.2
94 5 .94-7 94.8
94.9 95.0
500
88.0% 89.8 90.4
913 91.9 92.8 93.3 . `. 93.7 94.0.
94.3 ' 94-5 94.6, . 94.8 95.0 ' 95.1 95.2 95:3
' EFFICIENCIES OF 3-- THICK JOHNS-MANVILLE ASBESTO-SPONGE FELTED SECTIONAL . PIPE INSULATION ON VARIOUS SIZES OF PIPE
Inches'
54................ 3/4................ 1 ...................
1*4................... 1}4................... 2 ...................
2 Vr................... 3 ................... 3%...................
4 ................... iy2................... 5 ...................
6 ................... 7 ................... 8 ...................
9 ................... 10
........................ ........................ ........................
........................ ....................... ........................
........................ ........................
.....................
....................... ....................... ........................
........................ ....................... .......................
....................... .. .
Temperature Difference Between Steam in Pipe and Air Surrounding Pipe
50
100
150
200
250
300
350
400
Per Cent. Efficiencies
76.8% 79.7 81.9
83.5 84.7 86.5
87.5 88.4 89.0
89 5 89.9 90.2
90.7 91.1 91.3
91.5 91.7
78.9% 81.7 83.5
85.0 86.3 87.7
88.7 89.5 90.0
90.5 90.8 91.1
91.5 91.9 92.1
92.3 92.5
80.6% 83.1 64.8
66 2 87.2 88.7
89.6 90.3 90.8
91.2 91.5 91.8
92.2 92 5 92.7
92.9 93.0
82.1% 84.5 86.1
87.3 88.3 89.6
90.5 91.2 91.6
92.0 92.2 92.5
92.9 93.2 93.4
93.5 93.G
83.4% 85.6 87.1
88.2 89.1 90.3
91.1 91.7 92.1
92.5 92.8 93.0
93.3 93.6 93.8
93.9 94.0
84.6% 86.6 88.0
89.1 69.9 91.0
91.7 92.3 92.7
93.0 93.3 93.5
93.8 94.1 94.2
94.4 94.5
85.8% 87.6 68.9
89.9 90.6 91.7
92 4 92.9 93.3
93.6 93.8 94.0
94.3 94 5 94.7
94.8 94.9
87.0% 88.6 89.8
90.8 91.4 . 92.4
93.0 93.5 93.8
94.1 94.3 94.5
94.8 95.0 95.1
95.2 95.3
450 .
88.1 69.6 90.7 91.6 92.2 93.1
93.5 94.1 94.4
94.6 94.8 95.0 95.2 95 4 95.5
95.6 95.7
500
89.1% 90.5 91.5 92.8 92.6 93.7
94.2 94.6 94.8
95.1 95.2 95.4 95.6 95.8 95.0
96.0 96.1
16
CRMC-003380
Johns-Manville Service to Railroads
Johns-Manville 85% Magnesia Sectional Pipe Insulation
For the insulation of pipes conveying steam
OHNS-MANVILLE 85';% Magnesia nesses from standard (approximately V
J Pipe Insulation combines the high nonconducting qualities of carbonate of
thick) to 3" thick, in 3-foot sections with canvas jacket: and brass-lacquered bands,
magnesia and asbestos, affording a light, to fit standard pipe sizes up to and includ-
efficient insulation. Under; actual service- ing 12" in diameter;. For larger pipes,:
conditions, Johns-Manville 85% Magnesia curved segments or blocks are supplied,
has proven itself to be the most durable and efficient insulation of . the ' moulded ' Also furnished in blocks for covering
type. The Johns-Manville manufacturing/ boilers> boiler flues and other large regular
process produces an 85% Magnesia with and irregular surfaces, such as steam and
the, maximum number of voids or minute receiver pipes on Mallet _ locomotives,
dead-air cells which increase its natural Blocks 3- x 18 or 6. x 36 , in thicknesses
resistance to heat transmission and reduce from % to 4 .
its weight. In addition, this process pro- Specifications for the application of
vides maximum mechanical strength con- Johns_ManviUe 85% Magnesia Insulation
sistent with high efficiency.
wm be found on the following page.
The efficiencies of Johns-Manville 85% For descriptive data on this insulation
Magnesia are given on pages 19 and 20.
in sheet and block form, see page 40.
Johns-Manville 85% Magnesia Sectional See approximate weights and price list Pipe Insulation is made in various thick- on page 32.
17
CRMC-003381
Johns-Manville Service to Railroads
Standard Specifications for Insulating Steam Pipes with Johns-Manville 85% Magnesia Sectional Insulation
All steam piping shall be insulated with JohnsMahville 85% Magnesia Sectional Insulation of proper size and thickness, with all joints sealed with Johns-Manville Insulating Cement. (See note "A".)
The bodies of all flanged fittings and all screwed fittings, including valves of the larger sizes (4" and over) shall be insulated with block and cement insulation of the same material and thickness as is used on the pipe lines on which they occur. The block insulation shall be se curely wired in place with annealed iron wire and all joints shall be filled with insulating cement. The insulation shall be finished with Johns-Man ville Insulating Cement troweled to a smooth and uniform surface.
All fittings smaller than 4" in size shall be in
sulated with Johns-Manville Insulating Cement
applied in layers, each about
thick, to the
same total thickness as the adjacent pipe insula
tion. Each layer of this cement is to be allowed
to dry before the next layer is applied and each
. layer, except the last, is to be. applied with a
- rough surface.. The last layer is: to be troweled
to a smooth and uniform surface.
% All flanges shall be insulated by method "A" or
"B," depending upon whether flange insulation is to be removable and replaceable or non-replaceable.
Method "A"--Use No. 19 half-inch mesh gal vanized iron wire netting for forming frame for the removable and replaceable flange.
This wire mesh should be cut into two pieces of such a size that each piece will encircle onehalf (*4) the flange, and with the ends turned down so that they will meet and come in contact with the insulation on the pipe.
Attach to this wire mesh frame Johns-Man ville 85% Magnesia blocks or sectional insula tion of proper size and length and wire in place with wire lacing.
Apply on the ends of this removable frame Johns-Manville Insulating Cement of the same thickness as that of blocks or sectional insula tion, then apply, over entire surface of flange cover, one-half inch finish of Johns-Manville In sulating Cement.
Method "B"---Apply built-up block and cement. insulation of the same material and of the same thickness as tlie adjacent pipe insulation, as de scribed above for fittings. ./.: /. -
Finish of Insulation
All of the. above insulation, including fittings, valves and flanges, shall. beTfirially. finished and additionally protected with 8-punce .canvas,.neatly'served, on,-over.rosm-sized. paper, and this canvas painted either with fireproof paint, or lead
and oil paint, of the color desired, ...This, extra canvas covering to be placed over the canvas jacket furnished with this insulation. (When re canvasing is not. desired or considered unnecessary, see note "B.")
Weatherproof Jacket
If piping is Ideated out-of-doors and exposed to the weather, the additional protection of 8ounce canvas and'paint may be omitted and in its place the insulation shall be protected with a Johns-Manville. Asbestos Weather-proof Pipe In sulation Jacket secured with rings formed of No. 16 copper wire wound once around the jacket
and ends twisted tightly together. These wire rings are to be placed on four-inch (4") centers. The jacket is to lap at least three inches (3") in all directions, and all horizontal laps are to be located on the side of the insulation and turned downward in order to shed all water from the surface. (See note "C.")
NOTE "A"--Johns-Manville maintains an en gineering department at each of its branches, which will, on request, recommend proper thick ness for various pressures and temperatures.
NOTE "B"--If insulation is not to be re-canvased, lacquered bands furnished with the insula
tion are to be applied, at 18" intervals, on all sectional insulation.
NOTE "C"--When extremely low tempera tures are encountered out-of-doors, special re commendations will be given by any JohnsManville Branch Engineering Department.
18
CRMC-003382
Johns-Manville Service to Railroads
What Insulation Efficiency Means
HE efficiency of an insulating ma
Tterial is expressed by a percentage, which is the per cent of heat saved by using the insulation as compared to what would be lost if no insulation were used and the pipe left bare or uninsulated.
The efficiencies of all insulations vary according to the size of pipe to which they are applied and according to the difference
in temperature between steam in the pipe and air surrounding the pipe, as well as according to thickness of insulation.
Complete information regarding the use of efficiency tables with examples to illus trate will be found on page 248.
For table showing total heat loss from bare pipes, see page 249.
EFFICIENCIES OF STANDARD THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE INSULATION ON VARIOUS SIZES OF PIPES
Pipe Size, Inches
Temperature Difference Between Steam in Pipe and Air Surrounding Pipe
60
100
150
2003
250
300
350
400
450
% ...................... . ....................
%............... .......... 1 .......................... -........... . .
56.1% 6s.6 65.8
61.7% 66.8 : : 68.7 : '
64.8% 68.6 71.2
'/ 2 -.-................... ........................;
G7 7 -
70.3 :
69.6 ' 72.1-
74.3 76.7 i "
72 9 74.3
78.6
'
2"4-", ....................__________ : "3 .......... ..................... . sy2:,;
75.8
78.0.
' ' 7b.7 ; ' 78.8 .
... 77.4- ' . 79.5
79.8 ' 80.6 : - 81.2
4 ...........................................
. 5
............ .;,,.i............ ____
' 60.4 ' ' 83.7 .
01.0
81.7
82.0 82.3
83.1 ; 83:5 :
83.7
:6 .7 .8
9 io
................. .................... .......... .......... '.;
.......... ...v............
.......... ____
........
81.4 82 0 : 82.3- _
. 82 5 : ' 82.8 "
82.7 ; 84.1 '
83.4 '
84.7 '
63:7 . : - 85.1
84.6 ' 85.2 8.4.2.:- . 85.4
Per Cent. Efficiencies
' 67.9% 71.3
73.7
70.5% 73.7 75.9
75.1 76.4 . 80.5
77.2 78.3 . 82.1 ' .
'81.6 82.3 --
82.9 . .
82.9 . '
83.6 84.2
84.5 : 84 6 85 0
85.8 83.0
86.2.
85.4 -
66:0 .86.2. .
86.4 87:1 87.3 .
86 4 : .86.5
87.5 87.6
72.7% 75.7 77.7
78 9 80.0. . 83.3
. 84.2 . 84 8
- 854 .
86.9 87 1 87.S
87.6 , 88 2 . .88.4 .
89:5 88.7
74.9% 77.7. 79.5
80.6 Bl:784.5
B5.5 80.0 86.5
88.1 88 3 88.4
88.7 89.2 .89.4
'83 5 89.6
76i8% 79.3 81.1
62.1 83.0 85.7' 1
86.7 ; -87.1 87.6
89.1 .89.3 89.4 -
89.7 90:1 90.2
-
90 3 90.4
78.7% - 81.1
82.6
83.5
84.4 87.0
87.9 ' :88 2
88.7 .
90.0 . 90.1
90.3
.90.5 . 90 91.1
- 912 . ,91.3
500
80.6% 82.7 84.0 85.0 85.7 88.2 88.9. 89.3 89.7 90.8 910 91.2
91.8 91.8 91.9 .
.92.0 92.1
EFFICIENCIES OF \y2" THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPES
Pipe Size, Inches
50
i/2 ............... I'a............................... ............... I ............................... ............
V/a............................... l'A............................... ............... 2 ............................... - -..........
2'/,............................... ............... 3 ............................... ............... 3%............................... ...............
4 ............................... ............... 4 J4............................... ............... 5 ............................... ..............
C ............................... ............ 7 ............................... ............ 8 ............................... ...............
9 ............... 10 ............................... ...............
63.4% 7C.S 73.0
76 3 78 o
,-:9.8 80.8 81.6
82 1 82.6 80.0
61.5 84.1 54.4
84.G 84.9
Temperature Difference Eenveen Steam in Pipeand Air Surrounding-Pipe
100
150
200-
250
300
350
400
450
Per Cent. Efficiencies
69.4% 72.8 75.3
77.1 78.2 80.5
81.6 82.5 83.0
83.6 64.1 84.5
85.0 85.4 85.8
86 0 86.2
71.8% 74.9 77.3
78.9 80.0 82.0
83.2 83.9 84.4
85 0 85.4 85.8
66 2 86.6 86.9
87 1 87.3
74.2% 77 1 79.2
80.6 81.7 83.6
84.6 65 3 65.8
66.3 86.7 87.0
87 3 87 C 87.9
88 1 86.3
76.2% 79.0 81 3
02.2 83.2 84.8
B5.7 86.5 86.9
87.3 87.7 88 0
68.3 88.8 88.9
89.1 80.2
76.1 o 80.6 82.5
83.6 84 6 85.9
86.9 87.6 88.9
86.3 88.7 89.0
89.3 89.7 89.9
90 0 00.1
80.0% 82.2 84.0
65.0 85.9 67.1
88.0 86./ 69.0
89.3 89.7 90.0
90.2 90.5 90,t
93.9 91.0
81.7% 83.8 85.3
86.3 87.2 88.3
89.1 69.6 90.0
90.3 90.6 90.8
91.1 91.3 91.5
91.7 91.8
63.5% 65.4 86.7
87.6 88.5 89.5
90.1 90.6 91.0
91.3 91.5 91.7
91.9 92.1 92.4
92.5 92.6
500
85.2% 87.0 68.1 89 0 89.9 90.6
91.1 91.6 91.9 92.1 92.3 92.5 92.7 92 9 93.1
932 93.4
19
CRMC-003383
Johns-Manville Service to Railroads
EFFICIENCIES OF 2" THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPE
Pipe Size, Inches
60
Vi............................... a............................... 1 ...............................
IK............................... VA............................... 2 ...............................
va............................... 3 ............................... 854............................... 4 ............................... 4K............................... 5 ...............................
6 ............................... 7 ............................... 8 ...............................
9 ............................... 10 ...............................
............. ............
............. ............ ............
............. ............
73.2 75.8 77.8
84.3 85.3 86.3
87.3 67.6
Temperature Difference Between Steam in Pipe and Air Surrounding Pipe
100
150
200
250
300
350
400
450
72.9% 76.0 ' 78.4
79.8 81.4 83.3
84.4 85.2 86.0
86.4 66.9 87.2
87.8 88.1 86.4
88.7 88.9
75.2% 78.S 80.4
820 83.2 64.8
65.9 86.7 87.2
87.8 68.1 88.4
88.9 69.2 89.4
89.7 89.9
77.1% 80.0 62.0
83.4 64.5 85.9
87.0 87.7
88.2
68.7 89.0 89.3
89.8 90.1 90.3
90.5 90.7
Per Cent. Efficiencies
79.0% 81.6 83.4
80.7% 83.1
84.8
82.3; 84.5
86.1
64 7 85.7 87.0
86.0 86.9 88.2
87.2 87.9 89.2
88.0 68.7 89.2
89.0 89.6
90.2
69.8 90.5 90.9
69.6 89.9 90.2
90.5 90.7 91.0
91.2 91.5 91.8
90.5 90.6 91.1
91.3
91.6 91.6
92.1 92.3 92.5
91.3 91.5
92.0 92.2
92.6 92.8
84.0% 86.0 87.3
88.4 69.1 90.2
90.8 91.4 91.8
92.1 92.3 92.5
92.8 93.0 93.1
93.3 93.4
85.3; 87.1 86.8
89.2 89.8 90.9
91.5 92.0 92.4
92.7 92.9 93.1
93.4 93.6 93.7
93.9 94.0
600
68.2 89.5
90.8 91.7
93.2 93.4
93.8
94.2 94.8 94.4 94.5
EFFICIENCIES OF 2*4" THICK JOHNS-MANVILLE 85% MAGNESIA SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPE
Pipe Si2e, Inches
Temperature Difference Between Steam in Pipe and Air Surrounding Pipe
50
100
. 150 ;
200
250
300
350
400
450
Vi........................ ....................
l
Va........................ ....... ............
................ ____ .....
71.7% 76.4 78.0
74.6% 77.6,. 80.1
76.6%. 79.6
81.7 : .
1 Va................... ..
79.9
IK---...........- ......... 81.2
2 ........................ .. .................... : . 83.3
81.9 .. 83.1': 84.0.
83.2. ' .
84.5. ' 86.i: .
VA..-......... . . ;____ .
3 ........................ ............ '85.4
VA..,.......... ..
84.5 86.2
.
86.0. 86.9.-': 87.6. ,
87.1 87.9 , 88.6 .
4 ..................
86.8
VA.'.;.:............ .................... 87.2
5 ; . ............ . . ...... . , '87.6
88.0 '88.5.
88.8;-,
89.0 , 89.s;
, 80.7,':
G ............ '
'68.1
7 ....... ............... -........... 38.6
''69.2-..
90.1
89.7 " 90.5:
8 ! . ......................
-88.8
. 89.9. ' -90.7/
9
............ ..
____ " 89.0
90.1- / 90.9- '.
10
........../ :..-rv;.89.3 / 90.4.:.
91.1;;
78.4% 81.2 83.2
84.5 85.7 87.2
sail
88.9 89.5-
89 8 90.2 90.5
90.9 9i.3 : 91.5
91.6 91.8 ;
Per Cent Efficiencies
80.3% 82.8 84.6
82.1% 64.3 85.9
83.6% 85.6 87.1
86.9 85.9
88.3 -
86.0 87.1 . 89.3
89.1 . 86.2 .90.3 ....
89.1 89.9 90.3,
90.1 90.8 91.2
91.0: 91.6 92.0 '
90.7 91.1 91.3
91.6
91.9 92.1
92.3 92.5: . 92 8-
91.7 92.0 92.2
92.4 92.6 . 92.8 '
93.1 ' 93.3 93:5
92.4 92.5.;
93.1 93:2
93.6. ' 93.7 :
84.9%
86.8 88.2
89.9 89.3 91.0
91.8 92.2 92.6.;
92.9 93.2 93.4
93.7 93.9 ` 94.0
94;1 : 94.2'
86.3; 87.9 89.2
90.8 90.1 91.8: -
92.5 92.9 93.2
'93.5 93.7 . 93.9',
94.2 94.4 ; 94.5'
94.6'. .94.7.`
500
87.7% 89.1 90.2
91 7 91.1 92.6 93.2 93.6 93.9 .
94.2 94.4 : 94.5 .
94.7 94 9 95.0 95/1 95.2
EFFICIENCIES OF. 3" THICK JOHNS-MANVILLE 85% MAGNESIA' SECTIONAL PIPE IN SULATION ON VARIOUS SIZES OF PIPE
Pipe Size, Inches
1Va
IKIK-
2
VA 33 K
4
5l'A
6
78
9 19
50
73.7% 77.0 79.5
81.3 82.8 84.7 85.6 66.8 87.5
88.1 88.5 68.9 89.5 89.9 90.1
90.4 90.6
Temperature Difference Between Steam in Pipe-and.Air Surrounding Pipe-
100
150
200
250
300
' 350
400
450
76.3% 79.4 81.4
83.1 84 4 86.2
87.3 88.2 68.8
89.3 89.7 90.0
90.4 90.S 91.1
91.3 91.5
78.5% 81.2 83.1
84.7 65.8 87.5
88.5 89.2 89.8
90.2 90.6 90.9
91.3 91.7 91.9
92.1 92.2
80.2% 82.8 84.6
65.9 87.1 68.5
89.5 90.2 90.7
91.1 91.4 91.7
92.1 92.6 92.7
92.8 92.9
Per Cent.. Efficiencies
81.7% 84.2 85.8
83.4% 65.5 87.0
84.8% 66.7
88.1
87.0 88.0 89.3
88.2 89.1 90.2
89.2 699 91.1
90.2 99.9 91.4
91.0 91.7 92.1
91.8 92.4 92.8
91.7 92.1 92.3
92.4 92.8 93.0
93.1 93.4 93.6
92.7 93.1 93.2
93.3 93.6 93.7
93.9 9.l 94.3
93.3 93.4
93.9 94.0
94.4 94.5
86.1% 87.8 89.1
90.1 90.8 91.9
92.5 93.0 93.4
93.7 93.9 94.1
94.4 94.G 94.8
94.9 95.0
87.3% 86.9 90.0
91.0 91.7 92.6
93.1 93.7 94.0
94.2 94.4 94.6
94.9 95.1 95.2
95.3 95.4
500
88.4% 89.9 90.9 91.8 92.3 93.3
93.8 94.2 94.5 94.8 94.9 95.1
95.3 95.5 95.6
95.7 95.8
20
CRMC-003384
Johns-Manville Service to Railroads
Johns-Manville Improved Asbestocel Sectional Pipe Insulation
Every section of Johns-Manville Improved Asbestocel Sectional Insulation is marked with a red band on the inside of each end
in the same position shown by the shaded area in the illustration. This mark distin
guishes this more efficient, stronger Im proved Asbestocel from ordinary coverings.
OR insulating pipes conveying steam Johns-Manville Improved Asbestocel
`at medium or..low pressures or. for Sectional Pipe Insulation is furnished.; in
pipes conveying hot water, . ^
2, 3, 4, 5 and 6 ply thicknesses, each ply
Johns-Manville -Improved Asbestocel is approximately
thick.: It is made in: 3-
. '.a cellulartype of- ihsulation ma:de up of foot sections with canvas jacket and brass-
alternate layers of plain and corrugated lacquered bands,: to fit standard sizes of .
asbestos felt, which form a multitude of pipe-
\
air cells closed upon themselves, so that . each chamber contains dead air that can
not circulate. These dead air cells are formed by the corrugations^ which run in
Specifications for Johns-Manville Im proved Asbestocel Insulation will be found on page 23.
two directions, longitudinally and circum Also furnished in sheet and block form
ferentially.
for boilers, flues and other large regular
Because of its cellular structure, longi tudinal circulation of air is prevented.
Improved Asbestocel is strong and dur
surfaces. Sheets, 36" x 36" and blocks 6" x 36", 4" x 18", and 3" x 18", or special sizes, in thicknesses from %" to 4".
able because the cells form numerous For descriptive data on this insulation
arches which give the insulation strength, in sheet and block form, see page 42. and this construction accounts for its abil
ity to withstand vibration and wear and See approximate weights and price list
tear.
on page 32.
21
CRMC-003385
Johns-Manville Service to Railroads
Johns-Manville Fine Corrugated Improved Asbestocel Sectional Pipe Insulation
The smaller cells give greater strength and assure increased efficiency.
OR insulating train pipes or other. Johns-Manville Fine Corrugated Im
Fpipes conveying steam at medium or proved Asbestocel Sectional Pipe Insula-
: : low pressures dr for pipes'conveying ; tion is furnished in 4 arid 6 ply thicknesses
hot water. Johns-Manville Fine ^ Corrur: in 3-foot sections with canvas jacket and
-gated Improved -Asbestocel is a cellular, brass-lacquered bands ;to fit standard sizes
type of: insulation made up similar to the of pipes.
-.A V'A.:'v
Improved Asbestocel described on page 21, except that "the corrugations are smaller. However,: there .are 50% more laminations per inch of thickness and the additional small enclosed air cells provide greater efficiency.
In order to specify Johns-Manville : Fine Corrugated Improved Asbestocel, insert the words,-`Fine Corrugated" be fore the words "Improved Asbestocel" in the specification on the opposite page.
Due to the greater strength of the small cells, Fine Corrugated Improved Asbes tocel is even stronger and more durable than Improved Asbestocel.
As a result of smaller cells as described above, the conductivity of Fine Cor rugated Improved Asbestocel is lower than that of the regular Improved Asbestocel.
Also furnished in sheet and block form for boilers, flues and other large regular surfaces. Sheets 36" x 36" and blocks 6" x 36", 4" x 18" and 3" x 18", or in special sizes, in thicknesses from y2M to 4". For descriptive data on this insulation in sheet and block form, see page 42.
For prices, see price list on page 32.
CRMC-003386
Johns-Manville Service to Railroads
Standard Specifications for Insulating Pipes Conveying Low Pressure Steam or Hot Water with Johns-Manville Improved Asbestocel Insulation or Fine Corrugated
Improved Asbestocel Insulation
All pipes conveying low-pressure steam or hot water shall be insulated with Johns-Manville Improved Asbestocel Insulation of proper size and thickness. (See note "A.")
All fittings and valves shall be insulated with
Johns-Manville Insulating Cement, to be applied to a thickness equal to the adjoining pipe insulation.
All flanges shall be insulated by method "A" or "B," depending upon whether flange insulation is to be removable and replaceable or nonreplaceable.
Method "A"--Use suitable size and length of Johns-Manville- Improved Asbestocel Sectional Insulation to encircle flanges completely and overlap the adjoining pipe insulation at least two inches (2") on each side of the flange. Secure
this flange covering with wire and fill space between pipe and flange insulation with JohnsManville Insulating Cement and apply a thin coat of Insulating Cement over entire outside
surface of flange cover.
Method "B" -- First prime flange surface with a thin coat of Johns-Manville Insulating Cement applied so as to leave a rough surface.
When dry follow with successive one-half inch coats of Johns-Manville Insulating Cement until a thickness equal to that of the pipe insulation is obtained.
Each coat of this cement should be allowed to dry before the next coat is applied, and each coat should have a rough surface, except the final coat, which should be trowelled down to a smooth finish.
Finish of Insulation
All of the above insulation,., including-fittings, paint, of the color desired.. This extra, canvas
: valves and flanges, shall be 'finally finished- and ' cover to be placed over the. canvas jacket fur-
.'additionally- protected with S-ourice canvas, neatly nished with the-insuiatibhi^ '(When re-ca'nvasing
sewed on, over TOSimsized paper- and this canvas is not desired or considered unnecessary, see, note
painted with either fireproof paint, or lead and oil ` B."j
*
Weatherproof Jacket
1 If piping is located out-of-doors and exposed to the weather, the additional protection of 8-ounce canvas and paint may be omitted and in its place
the . insulation . shall'.be protected with a JohnsManville Asbestos Weatherproof Pipe Insulation Jacket, secured with rings formed of No. 16 copper wire wound once around the jacket and
ends twisted tightly- together. These wire rings . are to be placed on 4" centers. The jacket is to lap at least 3" in all directions, and all horizontal
laps are to be located on the: side of the insulation and turned downward in order to shed all water from the surface. (See note "C.")
NOTE "A"--Johns-Manville maintains an engineering department at each of its branches, which will, on request, recommend proper thick ness for various pressures and temperatures.
NOTE "B"--If insulation is not to be re-canvased, lacquered bands furnished with the insu
lation are to be applied, at 18" intervals, on all sectional insulation.
NOTE "C"--When extremely low tempera tures are encountered out-of-doors, special re commendations will be given by any Johns-Man ville Branch Engineering Department.
23
CRMC-003387
Johns-Manville Service to Railroads
Johns-Manville Asbestos Fire-Felt Sectional Pipe Insulation
An insulation that is partic ularly well adapted to high
temperatures.
OHNS - MANVILLE .Asbestos Fire- high temperatures and many other condi
J Felt; . Pipe. Insulation., iscomposed of asbest o s f ibr e f el ted together an d
tions; such as hot oil lines, gas engine ex haust lines, etc., where temperatures! are
molded into sections of. the' required size..especially high. For such conditions Fire-
This! composition assures high heat resist-, Feltis usually used for the layer of insula
ing: properties .and. the -process of/manu tion against the heated Surface and Asbes-
facture produces a strong resilient mater to-Sponge Felted Pipe Insulation is then
ial of good insulatingvalue, because of applied outside of the Fire-Felt, This re
the large number: of small air cells con sults in a combination which not only is
fined in its structure. - -r.:
suited to unusually high temperatures, but
Johns-Manville Asbestos Fire-Felt is unaffected by vibration, expansion and contraction and many other severe condi tions common to railroad and industrial plant service.
also is very efficient.
Johns-Mahville Asbestos Fire-Felt is furnished in sections 3 ft., long and. in thicknesses of 1" to 3", with canvas jacket and brass lacquered bands, to fit standard sizes of pipe. See approximate weights
Due to its high heat resisting properties, and price list on page 32.
Johns-Manville Asbestos Fire-Felt Pipe Also furnished in sheets 24" x 36" and Insulation is particularly adapted for use blocks 6" x 36", in thicknesses from to
on pipes conveying steam at unusually 4". For descriptive data, see page 43.
CRMC-003388
Johns-Manville Service to Railroads
Johns - Manville Asbestos Flexible Steam Pipe Insulation
Details of application of Johns-Manville Asbestos Flexible Steam Pipe Insulation.
/T'HIS Style of pipe covering, because , posite direction from the first. The cover:. | of its great flexibility, is admirably mg is then secured, with wire fasteners as
adapted to. many uses on. and about illustrated, Or with 1716" annealed iron
a locomotive, such/ as : steam pipes' to ! wire, fasteners being' located at 12 inch
: boosters, air pumps, injectors, lubricators, intervals.
VV-
head light generator, steam heat: to regur : The advantage of this method of appli-
lator, superheater damper, blower, stoker, cation is that it positively eliminates open
foot warmer, grate shaker, and other joints and consequent heat losses. The
steam pipes.
/ finished job is smooth and even over its
The illustration above shows how easy entire surface as compared to the uneven
it is to apply this covering. - Two layers and unsightly appearance where the ma-
.of Johns-Manville Asbestos Listing are terial is wrapped one.way and lapped over,
wrapped spirally, with butt joints, the All possibilities of burns are eliminated
second layer being wrapped in the op- where pipes are covered with this material.
Dimensions of Covering
1/16" x 1" for pipes up to and including 1" in diameter. 1/16" x 2" for pipes from 1" up to and including 2" in diameter. 1/16" x 3" for pipes from 2" up to and including 3" in diameter. This material also furnished in 1 yz" and 2l/2" widths.
NOTE--Used material may be re-applied as first layer, using new material as outside layer.
25
CRMC-003389
Johns-Manville Service to Railroads
Johns-Manville Asbestos Combination Spiral Pipe Insulation
Details of application of Johns-Manville Asbestos Combination Spiral Pipe Insulation
A l -VHIS insulation' consists , of one, layer . shaker. - Air purrip efficiency is greatly reJ_ of Johns-Manville Ceilinite Yk' thick, duced by condensation caused by heat' loss;
; cut. into v2^'' ; widths arid wrapped; from : uninsulated pipes. Moreover, eri-
spirally;around-' - the pipe,-, over which gineers arid firemen are indanger of being
Johns-Manville. Asbestos Listing is then . burned by coming in contact with: uniri-
; .wrapped spirally in the opposite direction, sulated hot surfaces.
; Both the Ceiliniteand the Listing are ap- The; insulation of these pipes as iUus.
plied.hutt Jomt., . I desired, a jacket of
above not only protects the loco
eight-ounce canvas may be sewed on over motive- creW; but it also effects the sav-
the Listing.
ing of a considerable amount of the heat
There is an enormous waste of coal otherwise lost through radiation,
caused by uninsulated pipes such as: steam lines to boosters, air pumps, injectors, lubricators, headlight generator, steam heat to regulator, regulator to flexible joint at tender, superheater damper, blower, stoker, foot warmer and grate
Johns-Manville Asbestos Combination Spiral Pipe Insulation is the most efficient covering for pipes where clearance conditions will not allow the application of standard thickness of molded pipe insulation.
26
CRMC-003390
Johns -Manville Service to Railroads
Johns-Manville Built-up Brine and Ammonia Insulation
Particularly well adapted to low temperature con ditions because of the efficiency and durability of the laminated con struction.
OR maintaining the extremely low
Ftemperature required in pipe lines conveying brine or ammonia or other
mg open. The effective method of sealing eliminates all chance of moisture accumulating between pipe and insulation and
cold liquids or gases. Johns-Manville then freezing and breaking the insulation
Built-up. Brine and Ammonia Insulation open,
consists of several, layers of insulating felts carefully applied around pipes to be
This form of insulation should be ap-
insulated.
plied by Johns-Manville. Applied prices
' " ",
quoted on request.
On account of the high insulating qual
ities of the hair felt used, .the flexibility of The conductivity, of Johns - Manville
hair felt and the method of sealing, Johns-1 Brine and Ammonia Insulation is .30
Manville Built-up Brine and Ammonia In- : B.t.u., and the conductivity: vof cork is
sulation is: not; only, -highly efficient as an about .35 B-t.u..per; square foot-per degree
insulator,: but will withstand contraction ' temperature difference per hour per inch :
and expansion without cracking or break- thickness,. .
HEAT
TRANSMISSION THROUGH
Pipe'. Size -
2 LAYER . Per lin. ft. Per si.
cf pipe of -:;e
, 3.LAYER ,
1 LAYER
Per'lin.;ft. Per sq. ft . \Pef. lin. ft. Per sq. ft.
of pipe . cf pipe
of pipe of pipe
` BUILT-UP BRINE AND AMMONIA INSULATION
The rates of heat
. X'2 3 .
-i'
ui* 2
inches.-............. inches .i .... inches. ..............
inches...1......... inches................ inches................
.. .086 . . .09j . . .107
. . .124 .132
. . .149
.390 .345 .310
.285 .255 .240
-074 .079 .088
.102 .109 .120
.
.331 .. .288 .257
.235 .218 .193
, ,065 .070 .078
.090 .095 .104
.
.295 .255 .227
.206 .190 .167
transmission given here are expressed in B. t. u. per hour, per degree temper ature difference be
2- ; inches................ 3 inches................ 3" ; inches................
4 inches................ 41 - inches................ 5 inches................
.. .167 .. .192 . . .211
. . .228 .. .247 .. .268
.222 .210 .201
.194 .188 .184
.133 .151 .165
.176 .190 .205
.177 .165 .157
.150 .145 .141
.114 .128 .138
.148 .158 .170
.151 .140 .132
.126 .121 .117
tween fluid in the
6 inches................ . . .307
.177
.233
.134
.211
.106
pipe and air sur
7 inches................ .. .343
.172
.257
.129
.230
.102
rounding pipe, per linear foot of pipe
S inches................ . . .380 p inches................ .. .415 10 inches................ . . .455
.158
.165 .162
.282
.307 .335
.125
.122 .119
.250
.273 .192
.099
.097 .111
1
and per square foot
12 inches.............. . . .528
.158
.387 .116 .311 .093
of pipe surface.
27
CRMC-003391
Johns-Manville Service to Railroads
Specifications for Insulating Pipes Containing Brine and
Ammonia or Other Cold Liquids or Gases with Johns-
Manville Built-up Brine and Ammonia Pipe Insulation
All pipe lines, including fittings and flanges it is interrupted by fittings, hangers, etc. These
and other apparatus containing brine or ammonia, sealing caps shall be at least two ply in thickness
or other cold liquids ot gases, shall be insulated and shall extend over the felt and under the out
with Johns-Manville Built-up Brine and Ammo side sealing membrane and shall be coated with
nia Insulation of the proper thickness. Where sealing compound the same as the outside mem
temperatures are between 15 F. and 50 F. use brane on the pipe.
two layer insulation and where temperatures are between minus 10 F. and plus 15 F. use three layer insulation.
All piping and other surfaces to be insulated shall be so located that there will be uninter rupted clearance around the finished insulation of at least 3" in all directions. The insulated piping shall not be located closely adjacent to any heated surface nor located in the same pipe chase or shaft with heated pipes.
FITTINGS:
All fittings shall be insulated separately from the adjacent piping, the insulation being of the same thickness and shall be applied and sealed in the same manner as on the pipe.
The insulation on each fitting or nest of fit tings is to be thoroughly sealed in with a sealing membrane not less than two ply thick and joined to the adjacent pipe insulation in such manner that there will be no interruption of insulation of
PIPES:
pipes and fittings.
All surfaces to be insulated shall be thoroughly cleaned and dried before insulation is applied and the system shall not be put in operation until the insulation work is completed. .
Wrap; .'pipes spirally with 'Johns - Manville
Waterproof Mefobfane so that all surfaces shall
HANGERS:
Each hanger is to.be insulated separately, the same as the fittings, running the insulation along the rod of a Hanger for a distance not less than 6" beyond the adjacent pipe insulation.
be covered with one; layer of, this .membrane.
ACCUMULATORS, TANKS, ETC.:
Then apply a layer of 1" .Hair Felt cut to proper
Surfaces of. accumulators, tanks,: etc.,: shall be.
length, so that all. longitudinal-and. abuttingjoints insulated in.die same, manner as specified above.
shall, fit .closely `tqgetherahd secure -this to. the Tor. .pipe lines, except that, .extra.- thicknesses of
pipe" by means,; of -a. wrapping of Two ply '.wrap insulation felts may'be 'required pn: account of
ping ...tyrine. wo.upd .spirally :,q.n.- .approximately 1" lowertemperatures;1-'{Aril exposed ends1- shall be1
centers.,. Then apply additional-layers of 1" Hair sealed in. with'sealing cap's.'."v:\v ; A
Felt in order to give the.tHichness specified above
and apply these1 so that all longitudinal and abut
FINISH GF INSULATION: `
ting joints: shall be staggered; or broken.
All of. the, above insulation exposed.to. view
When the proper number of plies have been shall be finished with a jacket of 8. oz. canvas,
applied, wrap, spirally with; Johns-Manville sewed on over a layer of oiled paper and a layer
Waterproof Membrane so that at no placeshall it of rosin-sized sheathing paper. This .canvas
be less than two ply thick. Apply to the surface of jacket shall be thoroughly sized and painted with
the outside waterproof membrane two coats of not less than: two coats of a first quality .lead and
Johns-Manville Waterproof Sealing Compound, oil paint.
allowing the first coat to set.before applying the NOTE: Johns-Manville maintains an Engin
second.
eering Department at each of its Branches which
A sealing cap of waterproof membrane shall will, on request, recommend proper thicknesses
enclose the end of the felt insulation wherever for various special conditions and temperatures.
Johns-Manville Built-up Hair Felt Insulation
OHNS - MANVILLE applies built-up As flow of water, duration of low tem-
J hair felt insulation in required thick- peratures and other factors have much to ness and number of layers to prevent do with the thickness and method of apthe freezing of pipes conveying water and plication, each case should be referred to
subjected to severe conditions.
the nearest Johns-Manville Branch.
28
CRMC-003392
Johns--Manville Service to Railroads
Johns-Manville Anti-Sweat Sectional Pipe Insulation
Showing the broken joint construc tion which eliminates through joints.
OR insulating pipes conveying cold
Fwater or other cold liquids at temper atures abqve :3? degirees Fahrenheit.
Johns-ManviUe Anti-Sweat Pipe Insu lation; is a combination of insulating felts that retard the flow of/heat, and moist; air to the pipes, and v Asbestos waterproofed - felts;, that protect; the--'. ihsulating,-..;.felts against the admission of .moisture.;. ; ;;r -
The special broken joint construction eliminates longitudinal.and abptting.joints that, extend from- the outside of the cover ing, to the pipe in ordinary: pipe covering construction. Each section is divided into two equal thicknesses in such a manner that the outer layer can be turned; around the inner layer and slipped lengthwise to a position where both the longitudinal and circumferential joints in the outer and in ner layers are widely removed from each other. This greatly increases the efficiency and durability of the insulation.
Johns - Manville Anti-Sweat is con structed of insulating felts protected by waterproofed felts, placed where they are most needed: one layer next to the pipe, two layers between the two layers of in
sulation, and two layers on the outside of
the insulation. . .
}
Anti-Sweat Insulation performs two im portant functions! It prevents the warm moist air from coming into contact with the pipe where the moisture from the air would condense and drip off. Such drip ping is unsanitary, and also is costly be cause of; damage to merchandise located below-the pipers,- V A'" 'aA."
The second function of `Anti-Sweat In sulation is that by prevehting heat absorp tion by the pipes it keeps the contents of the pipes cold. Where cold, drinking water is required, or where cold water is necessary in manufacturing' processes, it must be kept cold by insulation or re cooled mechanically. It costs less to keep water cold than to re-cool it.
Furnished in thicknesses of
1",
IV2" and 2", in 3-foot sections with canvas
jacket and brass-lacquered bands to fit
standard pipe sizes.
Not furnished in sheet and block form. See approximate weight and price list on page 32.
29
CRMC-003393
Johns-Manville Service to Railroads
Heat Transmission through Johns-Manville Anti-Sweat Pipe Insulation
Rates of heat transmission are given in B. t, u. per hour per degree temperature difference per linear foot and per sq. foot of pipe surface
Pipe
Size
Vi .............................................. K".......................................................... l" ............................................ 1VA" . 154".............................................. 2" ............................................... 2^".............................................. 3" .............................................. 3H>".............................................. 4" ............................................
Per
LirFt.
.212 .245 .285
.374 .443
.518 .511 .685 .757
Thick
Per
Sq. Ft.
.963 .891 .830
.777 .751 .713
.688 .666
.655 .643
RATES OF HEAT TRANSMISSION
3A" Thick
Per Per
Lin. Ft. Ft.
.185 .212 .243
.284 .312 .367
.841 .770 .706
.653 .627 .591
.425 .497
.553 .611
.564 .542
.528 .518
1" Thick
Per Per
Lin. Ft. Ft.
.167 .189 .215
.249 .272 .318
.758 .687 .625
.572 .546 .512
.364 .423
.484 .462
.468 .515
.447 .437
i'.;" Thick
Per Per
Lin. Sq. Ft. Ft.
.143 .160 .180
.642 .581 .523
.205 .223 .257
.473 .448 .413
.292 .337
.388 .367
.359 .404
.353 .343
2" Thick
Per Per
Lin. Sq. Ft. Ft.
.128 .142 .158
.581 .515 .460
.194 .221
.249 .284
.311 .338
.389 .356
.331 .310
.297 .287
Standard Specifications for Insulating Pipes Containing Cold Water
All cold-water mains, risers and branches, shall, Membrane, wound on spirally and coated with
be.insulated:with Johns-Manvilie .Anti-Sweat In- Johns-Manville Waterproof Sealing Compound.
: sulatiori 1" thick i(for unusually severe conditions,
All pipe and fitting insulation exposed to view
-use general . recommendations given ; below);:- ap- ; . shall : be enclosed , in an; extra jacket of- 8-ounce
: plied in two layers with all Joints broken, tightly canvas, applied over a- lining of heavy rosinrsized
drawn together and stapled in; place: . All joints, paper and sewed , in. place, seams to be located
. shall be-sealed by -means.of .Johns-Manville Mois- where least visible.
T
. ture-Resisting Cement applied \to the edges of the Where the lines are exposed to the weather this
insulation at the:joints, before They: are drawn to canvas jacket may be omitted, and in its place the
gether. All fittings .shall, be. insulated, with Hair insulation shall .be ^protected with, a layer, :of
Felt of the same thickness as the adjacent pipe Johns-Manville Asbestos Weatherproof Pipe In
insulation. This material'-shaH be cut' to fit The. sulation Jacket secured with rings of No. 16 gauge
`fitting and secured in place with close wrapping copper wire, applied on 4" centers. The jacket
of heavy jute twine. This insulation on the fit shall lap at least 3" in all directions and all hori
tings shall be thoroughly sealed by rneanS'of: a zontal laps are to look, downward, in order to
double wrapping of Johns-Manville Waterproof shed all water from the .surface.
General Recommendations
The above specification applies to insulation to prevent sweating under normal conditions, i. e., where temperature of water is over 50 degrees F., air temperature is less than 100 degrees F., and the humidity is not over 75%.
To maintain water temperature between 32 degrees and 50 degrees when room temperature is less than 100 degrees F. and humidity of air
is not over 75%, use 1J4" thick Anti-Sweat Pipe Insulation.
If humidity is between 75% and 80%, air tem perature not over 100 degrees F. and water tem perature is not lower than 50 degrees, 1*4" thick Anti-Sweat Pipe Insulation should be used.
For more severe conditions, consult JohnsManville Engineering Department.
30
CRMC-003394
Johns-Manville Service to Railroads
Johns-Manville Zero Sectional Pipe Insulation
The structure of Johns-Manville Zero Sectional Pipe Insulation adapts it exceptionally well to its
special service.
OHNS-MANVILLE Zero Sectional where temperatures are moderate rather
J Cold Water Pipe Insulation is con than extreme or where the length of time structed of a layer of 1" hair felt sur that the surrounding air would be below rounded by several layers of wool felt andfreezing-point is short, . -
with a layer of saturated wool felt inside
Where pipes run out of doors and are
the hair felt.. . This'prevents the hair .felt subjected to severe conditions or extreme
fromi coming' in direct, contact .with the. temperatures, Jbhns-Marivilie Built-up-
: pipe-.;
-
Hair Felt of: suitable thickness should be
Hair felt, one of. the-best known non applied. (See page 28;)
I!
conductors . of heat;, greatly- retards the
flow of heat frbm.the; water iii the pipe to
Johns-Manville Zero Sectional Pipe In
vthe cold surrounding air, and the'.wool felt sulation is: furnished ill one thickness only
jacket and the inner layer of saturated felt . (approximately '1%") in 3-foot 'sections
provide protection fbr the hair felt lining. : with canvas jacket ahd brass-lacquered
This material : is designed 'and- con- bands, to fit standard-pipe sizes.. .
. structed for insulating cold water pipes r 1 Not furnished in sheet and block form.
, that are located where there is a likelihood .. See approximate weight and price list on
of the water in the pipes freezing but page 32.
'
Johns-Manville Wool Felt Sectional Pipe Insulation
N inexpensive insulation for cold
A water pipes. Made of laminations of wool felt in sections 3 ft. long, in three styles: "Standard"--1" thick, with an inner lining of one layer of asbestos paper.
"Champion" or "Express"--thick;
same construction as "Standard/' "Aqua" or " C-B "--thick; same
construction as "Standard".
Not furnished in sheet or block form. See next page for approximate weights and list prices.
31
CRMC-003395
Johns-Manville Service to Railroads
Approximate Weights of Johns-Manville Sectional Pipe Insulations
(WEIGHTS GIVEN ARE POUNDS PER STANDARD 3-FOOT SECTION)
Kind of Covering
Thick ness 3
1" i.'r 1 W 2' 2
Pipe Sues 3" 3 2" 4" 4**2** S" 6" 7" 8" 9" 10" 12"
-
85 Magnesia'................. -
Std. 1 0*
3' Std. 1 2"
4.35 4.70 5.26 6.00 6.42 7.38 8.31 9.52 10.60 11.60 12.50 13.80 15.70 17.70 19.70 21.70 23.80 27.80 8.95 9.50 10.40 11.40 12.00 13.30 14.70 16.50 17.90 19.40 20.80 22.70 25.60 28.30 31.00 34.00 37.20 43.00 13.00 13.60 14.80 16.20 17.00 18.80 20.70 23.10 25.20 27.10 29.00 31.50 35.20 39.10 43.00 47.50 51.30 59.20 25.40 26.50 28.20 29.70 31.60 34.30 37.20 41.00 43.80 46.70 49.70 53.70 59.30 65.20 70.80 76.80 83.50 95.50 1.62 1.85 2.02 2.39 2.74 3.77 4.30 5.00 5.57 6.82 7.42 8.05 9.35 11.90 13.20 14.50 16.10 23.00 3.77 4.12 4.59 5.10 5.52 6.27 7.16 8.10 8.88 9.70 10.50 11.40 13.10 14.70 16.30 18.00 19.80 23.00 6.11 6.75 7.30 7.89 8.40 9.42 10.60 11.90 12.90 14.00 15.20 16.40 18.60 20.80 23.00 25.10 27.50 31.60
-i
* - Impr-oved Asbes- tocel.
* * --
Champion Wool Felt. . .. Zero...................
Std.
Std. 1 >" 2" 3' 2 ply
1" 1
v.* 1" .Std.
4.86 5.31 5.80 6.42 7.23 g.82 10.90 12.30 13.40 16.40 17.60 19.00 21.50 27.30 29.90 32.60 35.70 50.70 12.40 13.20 14.00 15.20 16.00 17.40 19.10 21.10 22.60 24.20 25.90
4.80 5.06 5.35 6.00 6.40 7.08 7.88 8.80 9.53 10.30 11.10 12.00 13.60 15.20 16.80 18.20 19.90 23.00 9.70 10.10 10.60 11.40 12.00 12.90 14.00 15.40 16.40 17.50 18.50 19.80 22.00 24.20 26.30 28.40 30.70 35.00 13.00 13.60 14.30 15.60 16.40 17.80 19.30 21.30 22.80 24.40 26.00 27.80 31.10 34.30 37.50 40.70 44.20 50.60 23.00 23.80 24.90 27.00 28.20 30.40 32.80 35.90 38.40 40.80 43.40 46.10 51.30 56.20 61.00 66.10 71.40 81.40
.90 1.04 1.18 1.37 1.49 1.74 2.02 2.37 2.64 2.92 3.19 3.48 4.05 4.60 5.14 5.68 6.26 7.34 1.27 1.42 1.60 1.86 2.01 2.37 2.71 3.15 3.50 3.87 4.20 4.60 5.37 6.04 6.75 7.47 8.25 9.65 2.00 2.19 2.40 2.69 2.90 3.30 3.74 4.25 4.67 5.09 5.54 6.00 6.89 7.72 8.56 9.41 10.35 12.00 2.46 2.67 2.90 3.21 3.44 3.90 4.35 4.95 5.40 5.87 6.33 6.85 7.87 8.80 9.7S 10.67 11.70 13.60 3.10 3.32 3.60 4.00 4.30 4.83 5.40 6.10 6.65 7.20 7.75 8.38 9.60 10.70 11.80 13.00 14.20 16.45 J .Jj 3.70 4.07 4.60 4.98 5.70 6.55 7.50 8.30 9.10 9.87 10.75 12.47 14.00 15.60 17.25 19.00 22.15 4.10 4.50 5.00 5.60 6.10 7.00 7.93 9.12 10.07 11.00 11.95 13.00 15.05 16.93 18.85 20.70 22.80 26.60 7.90 8.40 9.07 9.95 10.58 11.80 13.10 14.70 16.00 17.30.18.60 20.00 22.80 25.27 27.95 30.60 33.40 38.60 1.40 1.60 1.82 2.08 2.28 2.70 3.15 3.60 4.00 4.50 2.35 2.60 2.90 3.23 3.50 4.10 4.70 5.30 5.90 6.501 3.10 3.63 4,. 20 4.75 5.30 6.40 7.50 8.54 9.63`10.70 4.00 4.43 4.88 5.30 5.72 6.67 7.60 8.50 9.40 10.30
List Prices per Linear Foot for Johns-Manville Sectional Pipe Insulation
v> ."A (READ REMARKS BELOW TABULATION)
Thickness.
: I V" 1"' 1 `r 1
' Inside Diameter of Pipe
'
: ' . > '
Outside Diameter of Pipe
:-2 2" 3": -3 Y *- 4" 4U' 5V I-; 1 7 " i-s-". . 5"- 10 " 12 " *14" 16" 18" 20". 24" 30"
S
. ' iS: . i$-
5': S':"
$ : ;S'-' -j$ s is.1'... $ S- $ - $
$ $ 'S :
s-
.22' .241 .'27 :30 -.33- -.361 40 .4.5 .50 6C .65 ' .70 80-11:00 1.10 l',20 1.30 1.85 2:10 2.35 2.60 7 85 3 30 4.00
1 ' i?-Thick:.r.. .v..\ .46 .49.] 5? .5.6 :60' ;64`l 70 .76 .82 88 1 .941.001 10 1.20.1/35 1.50 1.65 1.85 2.10 2.35 2.60 2!85 3.30 4:00 2 " Thick ........ ./d :80; .85 -.90 :95 1.00 1.05 1.15 i.25 1:35 1.451.35,1 70' r.85';2.00 2.20;2.40 2.70 -3.00 3.30 3.60 4.0U 4.60 5:50
"DoubleStandard
" -1
Thick.............
.65 .70; .75 .80
Joints.................... i.20 1.35 1.40 . 1.45
1 .85! .9OM.O0 1.10 ! 1' 1155 1.65'. 1 ,0 1.90
l:20 l;4C 2.05 2;20
1 - 1 '< !... 1.50 1.601.80 2.2; 2:50 2:70 2.90 4.10
1 r 1 v L."'
2.35 2.50 2 70 290 3.15 3.40 3.65 4.10
4.60 5.10 5:60 6.00 7.00 8.40 ,
4.60 5.10 5.60 6.00 7.00 8.40
Inside Pipe Diameter
J
L" I'M `A
,, " 2 " ' 2
3" 3 :
4" 4*2* , 3
6" . ,7"
8" - Q,, 10":
Flange Covers . . .
S .30-
.36
.48
.54 .50
-.30 .3 3 .48 ..54 .50
$ S .30 I .30
.36 .36 .48 ! .48 .54 1 .54 .50 .50
$. .30
.36 .48 .54 .50
S 36 42 54 60
60
$ 42 48 60 78 70
S .48 .54 .70
.96 .80
S .54
.60 .80 1.20 .90
5 . .60'
./3 .95 1.50 1.00
5 .72
: ,.9t l.tc 1.85 1.30
$ 90
1 20 1.50:
2 25 1 60
i 1.30 1.60
2.00 2.80
1.90
$. 1:80 2.20
2.80 3.60 2.20
$ 2.40 3.00
3.60
4.40 .50
s 3.00 3.80 4.40 5.30 2.90
S ' 3.60
4.60 , .20 6.20 3.30
*85% Magnesia is made in Standard (approx. 1"), ll/2", 2", Double Standard Thick and 3" (broken joint) thicknesses. For pipe sizes from and including 14" in diameter it is furnished in segmental form.
** Applies only to 85% Magnesia.
These pipe insulations are supplied in sections three feet long, canvassed and with brass-lacquered bands.
Asbesto-Sponge Felted Insulation is made in thick nesses from Yi" to 4"; thicknesses 1'' and under, use list prices for Standard Thick.
Improved Asbestocel made in 2, 3, 4, 5 and 6 ply. Use Standard Thick list prices for all thicknesses.
Fine Corrugated Improved Asbestocel Insulation is made in 4 ply and 6 ply. Use Standard Thick list prices.
Zero Insulation is made in one thickness only, ap proximately 1*4". Use Standard Thick list prices.
Anti-Sweat Insulation is made in
33", 1". 1/4"
and 2" thicknesses; use Standard Thick list prices for
all thicknesses under 1".
32
CRMC-003396
Johns-Manville Service to Railroads
The Johns-Manville Underground System of
Insulation for Steam and Hot Water Pipes
HE Johns-Manville Underground
T System of Insulation provides a per manent, efficient and economical
of installation of them by Johns-Manville engineers.
The average efficiency of the Johns-
means of placing underground and insMuanville System is at least 90% when in
lating pipes conveying steam or hot water. stalled according to our specifications and
The system comprises not only the in by us or under our supervision. This high
tegral parts shown on page 35, but the efficiency is maintained for a long period
proper selection and arrangement of these of time on account of the character of the
parts and the installation or supervision materials used in the construction.
Insulating Material Used
For the base of the insulating material lated, it completely fills the space inside of
which surrounds the pipes we chose asbes the protecting and containing parts of the
tos -- a natural rock, unchanged by high system. It is extremely resilient and
temperatures,' ' immune to: moisture;' spongy, so that there is little tendency for
wear; rot and rust. To provide for maxi it to settle...
mum1 insulating. efficiency we combined.; The fact that Johns-Manville Asbesto-
specially selected fibres of this .asbestos;
rock with other'material of a. sponge-like r
nature .which, y^hen prdpdrly; mixed with
asbestos fibre,; forms the most efficieiit.and,
most durable insulating material for., un-,
derground work-^Johns-Manville Asbes-
to-Sponge Filling. "
%
Sponge Filling maintains its high initial ' heat insulating1 efficiency . year ;after' year without depreciation makes it the most economical insulation possible to use for this work. Its saving of heat does not diminish as- time goes on, and it is the "cheapest-per-year" of all underground
The. high and lasting heat insulating insulations..
UV'V'1
efficiency of Johns-Manville Asbesto-
Sponge Filling is due to the many "dead The correct amount and thickness of
air" spaces and cells which it confines, and this insulation has been accurately deter
to its base of indestructible asbestos fibre. mined for various conditions by the most
When packed around the pipe to: be insu- rigid tests.
Supporting Roll Frame
The Johns-Manville Supporting Roll Frame has been designed to provide sup port for the pipes and to insure that they may move freely when expanding and contracting.
This roll frame, anchored in a concrete
base, supports the entire weight of the pipes and their contents and prevents any load from being carried by the containing and protecting member. The movements of the pipes due to expansion and con traction thus produce no effect on the sys-
33
CRMC-003397
Johns-Manville Service to Railroads
tem. This method of support is sufficient to signed and made according to the number bear any weight required of it in service, and combination of pipes that may be
Johns - Manville Roll Frames are de- contained in the conduit.
Supporting Sections
The supporting section of the system is concrete base in which the roll frame is a most important part as it completely embedded and also acts as a connecting covers and encloses the roll frame and the link between the containing sections.
Containing Sections
The supporting sections are connected by containing sections, which complete the continuous stone protective member which surrounds the entire system and acts as a container for the Asbesto-Sponge Filling. The sections are split diagonally, so
that the lateral joints will shed water better than if the cut of the joint were straight, and each half of every section is numbered so that in the installation of the system mates.of each section will always be placed together.
Underdrain
-. Provision: ' is ,made to .prevent 'water. :frpm accumulating around the system and to drain or carry.it away by the use of an ;imderdrain of small .rtile'J0|pe-viaid;|vw.ith^ .open joints ;and ,storie, which is carried Up and: around the system to a-poirit above the lateral joints!
The design and proper location of an chors, anchor-pits, manholes and manhole covers are details carefully worked out by our engineers according to conditions.
Manholes or pits are used: as required by the nature of the installation. In a small installation there is no call for a large manhole, as the pipes may be an chored or a branch may be taken off in a small pit (commonly called a blind pit)
to which no ready means of access is. nec
essary.
"
,< Wherever there may be : valves, , expan-:
sion joints,; flanged joints; or other fea tures which:itsary to get at occasionally, and which cannot be placed in a building into which
the system runs, a manhole with a remov able but water-tight cover should be em ployed.
Where any part of the system termin
ates, whether at a building, anchor-pit or manhole, the ends are sealed in by spec ially designed shutters.
See pages 37 and 38 for detailed specifi cations.
34
CRMC-003398
Johns-Manville Sendee to Railroads
Integral Parts of the Johns-Manville Underground System of Insulation
- --------- --
SECTION SHOWINGiMETHQD-
OF CONSTRUCTION- AT - . - MANHOLE' !
35
CRMC-003399
Johns-Manville Service to Railroads The Johns-Manville Underground System of Insulation
in Course of Installation
Sections being split before being pieced intrench a* Pennsylvania Reform Schoo^Moiganze, Pa
36
CRMC-003400
Johns-Manville Service to Railroads
Specifications for Steam and Hot Water Pipes
to Be Installed Underground
1. All steam lines and returns and all hot
water lines that run outside of power plant or
buildings shall, as indicated, be run underground
and insulated by the Johns-Manville System of
Underground Insulation.
2. This system shall consist of:
(a) Roll frames and rolls for the support
of piping.
(b) Supporting sections for the enclosure
and support of the roll frames.
(c) Straight sections and unions for the
connections between supporting sec
tions and buildings or pits.
(d) Johns-Manville Asbesto-Sponge Fill
ing for the insulation of the pipes.
(e) Underdrain for drainage of system.
(f) Broken stone or gravel of suitable size
for surrounding lower half of system.
(g) Shutters to seal the ends of the system
. where it terminates, in buildings,..,
manholes, or pits.. '. ,
. -r
(h) Manholes and .-anchor pits to be pro-
. vided as indicated to allow for con- ;
trol of expansion and contraction -or ; ;
, for changes in direction or elevation
pf;the. system:-.: .Ur.v: J.U-V-/ v!..;.--
(i) Suitable covers for manholes.
The system complete and when installed shall
provide for the support of pipe or pipes at proper
intervals, so that neither the weight of the pipe
nor the movement of same due to expansion or
contraction will cause strain or stress to come on
the tile containing members of the system.
The containing members, (b) and (c), para
graph 2, shall be of a size that will provide not
less than three inches of space for insulation be
tween the top of pipe or pipes and the nearest
point of the containing member, and between the
side of pipe or pipes and nearest point of con
taining member. The space referred to, to be
measured between the outside surface of the pipe
and inside surface of the containing member.
The supporting sections shall be so designed
and made as to provide a suitable concrete base
extending from the broken stone or gravel bed
ding under the containing members up through
the special opening to the interior of the contain
ing members, and the .roll frames, are to be. set
into these bases when they are built.
The entire space in the containing member-not
occupied by pipe, rolls and, roll frames to be filled
with A'sbesto-Sponge Filling' a proper combina
tion of asbestos and suitable raaterial of a spongy
nature.
t-'.:
Material
3. 'All..material,,iisted.vun;de.r;:it:ems,:,(a:) to (e)
4. Material listed.under items
(g) and (h),
- inclusive-,;`;':and./item ;:;(i).;4paragfaph^2,;.to be .fur- paragraph.. 2, to be ..furnished'':by> party ' agreed .
nished by-johnsrMari.yiiie Inc,.
upon arid stipulated.hereafter.
Supervision of Installation
. 5. Johns-Manville Inc. shall -furnish a representative capable of supervising the installation of the system -above: described and all. work done by the labor required to install the system is subject to the approval of the Johns-Manville representative, whether said labor be furnished by Johns-Manville. Inc. or otherwise, as stipulated hereafter.
6. AU labor and tools required for the digging of trenches for the system, the handling of broken stone or gravel,: the back-filling of trenches after the insulation of piping has been cbtnpleted, and for the actual installation of the various parts of the system, shall be furnished by the party or parties stipulated hereafter,
NOTE TO ARCHITECT OR ENGINEER SPECIFYING
When possible it is advisable to consult with the engineering department at the nearest Johns-Manville branch regarding the selection of party or parties referred to in paragraphs 4, 5 and 6, as local con
ditions, the size of the installation, and the location of same have much to do with the selection of parties best qualified to handle various parts of the installation.
Whenever possible Johns - Manville
37
CRMC-003401
Johns-Manville Service to Railroads
recommends and desires to furnish its own men as well as a superintendent to install all items (a) to (g) inclusive, paragraph 2. There may be exceptions such as the in stallations of systems at some distant or
out of the way place or at some institution that desires to furnish its own labor. In all cases, however, the installation of the sys tem must be under the supervision of Johns-ManvilleInc.
Levels and Lines
7. Unless otherwise agreed, levels and lines for laying the system to true and proper grade shall be furnished by the engineer or owner.
The batter boards indicating such lines and levels shall be furnished and set at intervals of about 33 feet by the engineer or owner.
The Installing or Laying of Pipes to Be Insulated
8. It is to be understood by the steam-fitter or
In case any leaks or defects develop when pipe
contractor who is to furnish and install the pip is subjected to test, such repairs or replacements
ing to be insulated by the Johns-Manville Sys as are satisfactory to Johns-Manville Inc. are
tem, that no flanges, companion flanges or to be made before the system is insulated and the
flanged fittings are to be used where pipe is sur top halves applied.
rounded by the underground insulation, and that all such connections are to be made with extraheavy screw couplings or welded connections ac. cording to heating or steam-piping specifications covering that work.
All pipes to be anchored with suitable anchor ing devices furnished by the steam-fitter and pro per provision, made for expansion as shown in plans and specifications.
Where pipes are run through walls or through ; Furthermore, the piping shall be placed and shutters--item (g) paragraph 2--where the sysconnected on rolls; as they are provided by party installing same, as soon as said rolls have been - -tem or part of- same, begins and terminates, the installed and are-ready for the pipe. And before .steam-fitter shall furnish and place around pipe,
the Asbesto-Sponge Filling and top halves ofi the> . sleeves made of the next size of pipe that may be
-.system -are-' in, place,: the steam-fitter ;or con .. . slipped over pipe to be insulated, and these sleeves
tractor placing the piping shall subject the-pipe shall be of, such a length as to extend entirely
placed to a hydrostatic; test ib.utually agreed up through wall or shutter and from two to four
on by the: owner and Johns-Manville .Inc.
inches beyond;each side of wall or shutter.
NOTE TO ARCHITECT; OR-ENGINEER SPECIFYING
Next and finally, stipulate party or parties to provide labor and materials mentioned in paragraphs 4, 5 and 6.
38
CRMC-003402
Johns-Manville Service to Railroads
Johns-Manville Asbesto-Sponge Felted Sheets and Blocks
Illustration shows laminated construction of this material.
OR efficiently insulating any surface
Eto which these sheets may be fitted, providing the temperature of: the sur-
withstand vibration, - shocks, and the rough usage of shipment and general handling without, crumbling, pulverizing
face to which the material is applied, does- . or the loss of value or, efficiency , so com-
not exceed .7509 Fahrenheit. . ^
mon to moulded and similar insulations,
: Johns-Manville Asbesto-Sponge Felted The? can be removed and replaced with-
Sheets and Blocks are constructed by ut injury.
'.,AA.'
building up to the required size and thick- ': Asbesto-Sponge Felted Sheets and
ness a number of sheets ,of Asbesto- Blocks are flexible, and conform to curved
Sponge Felt, of the same kind as used in surfaces of boilers, tanks, etcJ, without the the manufacture of Asbesto-Sponge Felt- necessity of moulding specially for each
ed Pipe Insulation. . - .
'
required radius which is necessary in the
The remarkable efficiency of this mate- case of moulded insulation.
rial is due,; to the enormous number of minute confined dead air spaces in the felt itself as well as the dead air spaces formed between the layers of the felt as built up to produce the finished product.
The relatively large sizes in which Asbesto-Sponge Felted Sheets are fur nished assure fewer joints and less time and labor for application than in the case of materials which are furnished only in
The advantages of Asbesto-Sponge block form.
Felted Insulation lie in its high efficiency and the fact that it retains this high effi ciency throughout its long life.
Furnished in sheets 24" x 36" and blocks 6" x 36", from to 4" in thickness.
For efficiencies of Johns-Manville As
On account of the materials used and besto-Sponge Felted Sheets and Blocks,
the manner of constructing Asbesto- see page 48. For approximate weights Sponge Felted Sheets and Blocks they and list prices, see page 49.
39
CRMC-003403
Johns-Manville Service to Railroads
Johns-Manville 859 Magnesia Blocks
For insulating flat, curved and irregular surfaces.
OHNS -MANVILLE 85% Magnesia that can be broken in order to apply it to
Blocks are composed of 85% carbonate the irregularities.
of magnesia and 15% asbestos fibre, Furnished in blocks 3" x 18" and 6" x
molded, into block form. This material is 36", from to in thickness,
particularly; adapted to conditions where For efficiencies of Johns-Manville 85%
it is necessary to use material- that is light Magnesia Blocks,' see page 48.
.`
- in weight, or where surfaces are. so irregu- See approximate weights and price list
lar, that : it is necessary to use a material- on page 49. - - j
Johns-Manville 85 '/ Magnesia Locomotive Boiler and Air Pump Lagging
WENTY-FIVE to thirty years ago fit the surface of the boiler, in accordance
T wood- was: the standard lagging for : with blueprints submitted by the railroads locomotive boilers in this country, or builders, giving correct dimensions.
while at the present time practically all boilers are lagged with 85% Magnesia, which combines the high non-conducting qualities of carbonate of magnesia and
The magnesia lagging used in boiler in sulation can readily be applied in blocks ranging in length from 24 inches to 40 inches and 6 inches wide. In order to ob tain a uniform outline it is the common
asbestos in a light, highly efficient insula practice to taper the blocks to provide for
tion. This can be furnished in various the thickness of the boiler sheets where
thicknesses, curved, straight or tapered to they lap at the seams.
40
CRMC-003404
Johns -Manville Service to Railroads
It is highly im
blocks should be
portant to insulate
used. The blocks
boilers, domes, cyl
are applied by wir
inders, and large
ing them fast and
surfaces because if
finishing with a
not insulated these
coat of Johns-Man-
surfaces will radiate
ville Asbestos Insu
a great deal of heat
lating Cement ap
and consequently
plied in two layers
waste fuel. These
over hexagonal
surfaces are suc
Showing lagging in place.
wire reinforcement.
cessfully insulated with 85% Magnesia For pressures of 100 lbs. and upward 2"
Blocks which are easily applied, as shown below, remain permanently in place and are extremely light in weight.
Insulating these surfaces with JohnsManville 85% Magnesia Blocks will give much better.results than if insulating ce ment is used because the 85% Magnesia is a much more efficient: insulation.
85% Magnesia Blocks applied and finished as described above should be used.
For pressures below 100 lbs. use 1%" 85% Magnesia Blocks applied and finished as described above.
We also furnish complete sets of 85% Magnesia Lagging for all types and sizes of air pumps. .
For list-prices see, page 49. Prices for
, For . complete insulation1
to 2" air pump lagging-quoted on application.
Showing method of applying Johns-ManviUe . 85*^ :Magnesia Locomotive Boiler Lagging.
Method of Application.
Wires are passed around the boiler at about 4 inches from the ends of every course of blocks. Special T-hooks for fastening engage the wires, and the blocks are slipped under the hooks, which hold them firmly in place. This method of fastening permits the removal, when necessary, of a single block without dis
turbing the others. When all blocks are laid, a planished jacket is passed around the lagging and fastened on, thus closing the joints and binding the blocks securely together.
Blocks may be cut with saw, knife, or chisel.
41
CRMC-003405
Johns-Manville Service to Railroads
Johns-Manville Improved Asbestocel Sheets and Blocks
A particularly efficient sheet and block insulation that is light in weight and durable.
OR insulating medium or low pres
F sure boilers, feed-water heaters, dry rooms and other surfaces whose tem peratures are not extreme.
Johns - Manville Improved Asbestocel Sheets and Blocks are made of plain and
corrugated asbestos felts, several of which are built up one upon another until proper thickness of cellular structure is obtained.
The main corrugations are crossed at right angles by other corrugations at in tervals of about 1%", forming numerous enclosed dead air cells. This construction not only makes the sheet strong and dur able, but also eliminates circulation of air through the corrugations.
Asbestos Felt offers high resistance to heat and in cellular form provides parti cularly good insulation.
Furnished in standard sheets, coarse or fine corrugated* 36" x 36", or blocks 6" x 36", 3" x 18" and 4"x 18", from i/2" to 4" in thickness.. ..
See approximate Weights arid price list
on page 49.
;"
Johns'Manville Asbestocel
(In Flexible Roll Form)
OHNS - MANVILLE Asbestocel in
J flexible toll form is made by fastening together a plain and a corrugated as bestos sheet..
It is generally used for insulating hot air heater or furnace pipes* etc.
It is applied by wrapping one or more times around the pipe to be insulated and fastened on with wire wound around it spirally. Additional fastening should be provided by wire rings placed about every 18 inches. At least two layers of Asbes tocel should be applied on warm-air fur nace pipes.
To provide a neater finished appearance asbestos paper may be pasted over the sur
face of the Asbestocel after it has been wired on.
Furnished in rolls 3 feet wide containing approximately 250 square feet.
List Price
1 Ply (about thick). . .$0.10 per sq. ft.
42
CRMC-003406
Johns-Manville Service to Railroads
Johns-Manville Asbestos Fire-Felt Sheets and Blocks
An asbestos material especially adapted to insulating extremely hot surfaces.
OHNS-MANVILLE Fire-Felt Sheets Fire-Felt with the result that a highly
J and Blocks are made; by felting and efficient combination is obtained which moulding asbestos fibre into sheet or will withstand, higher temperatures than block form. The process used in the manthose to which the more efficient.materials
ufacture of Johns-Majiyjille Fire-Felt pro- may be applied direct.
.
. duces a heat resisting material of good in... sulating value, that is strong and resilient,
and that will not readily powder or crum ble even when , applied to .surfaces that move or vibrate.
Among the places where such combina tions are particularly desirable are furnace walls, oil stills and other apparatus oper ated at temperatures too severe for most other insulating materials;
Johns-Manville . Fire - Felt, due. to; its strength, durability arid high heat resist ing qualities; is - particularly; adaptable to many uses where the conditions are un usually severe, such; as the lining, of breechings or flues where the tempera tures are particularly high, and the lining of boiler tube doors where considerable mechanical strength is required to with
Johns-Manville Fire-Felt is furnished in standard sheets 24" x 36" and blocks 6" x 36", in thicknesses from %" to: 4".
The sheets rhay be furnished curved to radius in order to fit the surface to be in sulated. This permits of using full sized sheets on curved surfaces, instead of small
blocks.
stand the vibration due to opening and A decided advantage in the use of Johns-
closing of doors.
Manville Fire-Felt in large sized sheets is
Another use to which Johns-Manville that this permits of application with only Fire-Felt is especially adapted is for the a few joints, as compared with the large
first layer of insulation applied on a highly number required with a material furnished
heated surface where a material of high only in small blocks. This results in
heat resisting properties is required. Then higher efficiency, because the elimination
more efficient Johns-Manville insulating of joints eliminates a large source of heat
materials, such as Asbesto-Sponge Felted, loss.
85% Magnesia, or Fine Corrugated As- See approximate weights and price list
bestocel may be applied over the layer of on page 49.
43
CRMC-003407
sUfitgi^^ Johns-Martville Service to Railroads
Johns -Manville Thermo Fire-Felt Sheets and Blocks n
I
I
Exterior of sheet.
Section of block showing cellular center.
N improved, efficient sheet or block
A for insulating!, hot blast stoves in steel -plants, -kilns, and furnaces: in
be applied between a brick lining and an outside steel shell, as in the case of hot blast stoves in steel mills and other similar
industrial plants^ breechings, flues, boilecronditions. Thermo Fire-Felt is an insu
walls, etc, `-.T.
: - lation which.w-il.l remain securely in- place
t. Johns -Manville- Thermo Fire-Felt in spite of expansion and contraction of
Sheets and Blocks are made by felting and the brick lining.
molding: asbestos' fibre into sheets, of pro The application of Johns-Manville
per size arid thickness with a:, cellular Thermo Fire-Felt in large sheets gives
structure embedded in the center; of; each this material a decided advantage over
sheet. The construction - of; Johns - Man- materials furnished only in small blocks,
; ville Thermo Fire-Felt :is' unique, in that because the ; use; of large sheets requires
this cellular structure does not extend to only a few joints,, as compared with the
the edges of- the sheet, but is completely- large number required in the case of small
sealed in. Therefore, the efficiency of the blocks. Fewer joints mean higher effi
material is increased because of the con ciency, because the elimination of joints
fined air spaces. . ,
eliminates a large source of heat loss.
This construction is particularly desir
Johns-Manville Thermo Fire-Felt
able because in addition to giving in is furnished in standard sheets 24" x 36",
creased efficiency the cellular structure in thicknesses from iy2" to 4". This ma
adds strength and gives the desirable pro terial may be furnished also in curved
perty of resiliency, which makes Johns- sheets or sheets of special size.
Manville Thermo Fire-Felt especially
For efficiencies of Johns-Manville
suited to conditions where expansion and Thermo Fire-Felt Sheets and Blocks see
contraction are large factors.
page 48.
Johns-Manville Thermo Fire-Felt See approximate weights and price list
is especially desirable as an insulation to on page 49.
44
CRMC-003408
Johns -Manville Service to Railroads
Johns-Manville Vitro Fire-Felt Sheets and Blocks
OR the insulation of hot blast mains
Fand bustle pipes or particularly severe heat conditions, the use of Johns-
with the exception that the embedded cel lular structure is more rigid and has greater heat-resisting qualities.
Manville Vitro Fire-Felt between the shellFurnished standard in sheets 24" x 36",
and fire-brick is recommended. Thermally in thicknesses from l1/^' to 4".
efficient, this insulation is exceptionally
May be made in curved sheets or in
strong and durable.
sheets of special size.
Johns-Manville Vitro Fire-Felt is simi See approximate weights and price list
lar in construction to Thermo Fire-Felt on page 49.
Johns-Manville Asbestos Roll Fire-Felt
(Plain or Indented)
On account of its great flexibility, its insulating and heat esisbng : properties, :Asbestc>.S' Roll Fire-Felt is adaptable to a wide variety of uses.
T*) LAIN---A soft, flexible felt of asbes- / These indentations make the sheet more
tos fibre, used for a great variety of flexible so that-it can be easily bent to a
/ :: purposes where there is; need of an small radius., The indented construction.
insulating and Leat^fesisting felLthat may. : also provides greatereonfinement of dead
be folded, bent or .wrapped: around pipes air spaces when/the insulation -is wrapped
and.heated surfaces. : :-; ::
a.A:,
or built up on surfaces to be insulated. It
- It isespecially; adapted to :wrapping; around pipes which are too close to adja cent pipes, other equipment, or partitions to permit the use of sectional covering.
INDENTED--Made of the same ma terial as the plain Roll Fire-Felt except
is, therefore, more efficient than the plain material.
Both plain and indented Fire-Felt are
furnished in thicknesses of ^2.">
i c">
Yi" and
in rolls 3; ft. wide containing
that the surface of one side is indented at approximately 100 sq. ft. See page 49 for
close intervals over its entire area.
approximate weights.
LIST PRICES AND THICKNESSES
Thickness
:?" thick...........................................................
thick.......................................................................... /!." thick.......................................................................... J'' thick.......................................................................... iT thick..........................................................................
List Price Per Sq. Ft.
.................................................................... $0.16
.................................................................... .20 ...........................................................................26 .......................................................................... 30 .......................................................................... SO
45
CRMC-003409
Johns-Manville Service to Railroads
Johns 'Manville Vitribestos Sheets and Blocks
Curved sheets for lining stacks 'and-circular, ducts.
Flat sheets for lining breechings, square ducts, etc.
OR ..lining, smokestacks and flues, Johns-Manville Vitribestos Sheets are
Ebuilding theatre curtains and for use made either flat or curved to'any radius v: : where a strong, stiffy insulating sheet . .and on account of their insulating value
or block is required that will; resist teiri- are admirably adapted; to use' as a,stack;,
peratures up to 80d^F;';'hf;-hV-'v:^
. ' lining. They ar4 especially adapted to: the
V;
lining of steel stacks on .account of their
Johns-Manville Vitribestos is made of light weight,
asbestos felts which have been corrugated
,'
and built up to form a cellular sheet. Drawings showing arrangement of
These sheets are subjected to a treatment curved steel angles that provide for the
and process which vitrifies them and easy application of stack lining will be fur-
makes them more resistant to moisture nished upon request,
and high temperatures than other cellular
sheets which have not been vitrified.
Vitribestos when used as a flue lining or
in fireproof construction is held in place
The vitrified sheet has not, however, as and supported by bolts or steel angles, the
great an insulating value as untreated application of which depends upon the type
sheets and its use should, therefore, be of construction required. Full particulars
confined to those places which require the and details will be furnished by any Johns-
qualities referred to above.
Manville branch.
46
CRMC-003410
Johns-Manville Service to Railroads
Johns'Manville Asbestos Sheet Millboard
OR general use where sheet or board plants where fire protection is desired.
F is desired for protection against fire,
Standard sheets, 40" x 40", 42" x 44",
heat, acid fumes, etc. Made of as and 48" x 48".
bestos fibre and suitable binders. Exten
sively used for lining doors, partitions and
Made in three grades: Hard, medium
floors, and for a variety of heat-resisting and soft. Medium furnished unless other
purposes in factories, mills and power wise specified. Prices on application.
\
fastened'.: with . nails or . .........screws-- .. ... .. ..
WEIGHTS OF JOHNS-MANVILLE ASBESTOS SHEET MILLBOARD
Weights
Thickness
Per Sheet 40" x 40"
Weights Per Sq. Ft.
1^9-inch........... ............. 2.4 pounds.......... .............. 3.4 ounces
%-inch............ ............. 2.75 pounds.......... .............. 4 ounces
Ke-inch...........
.............. 5.3 ounces
f6i-inch........... ............. 5 pounds.......... .............. 7.2 ounces
5^>-inch........... ............. 5.5 pounds.......... .............. 8 ounces
J/g-inch........... ............. 7 pounds.......... ..............10 ounces
?3<rinch........... ............. 9 pounds.......... ..............13 ounces
Jfa-mch........... ............. 10 pounds.......... ..............14.4 ounces
J-^-inch........... ............... 14. pounds. ...... ......... .. .20.2 ounces
' $(6-inch........... ............... 17 pounds/. ... ......... .24.5 ounces
%-inch........... ............... 20 pounds'. .
......... 28.8 ounces
J^-inch........... ............... 25 pounds..... ......... 36 ounces
Johns-Manville Asbestos Paper and Roll Board
... The ; uses . of Johns-Manville- Asbestos Paper are large and varied; in general* it is used as a fire retardant. : Its thinness makes it necessarily less, efficient as an in sulator than either Johns-Manville Asbes-
tocel in flexible, roll form or Johns-Man
ville Roll FirerFelt, and in order to obtain
appreciable insulating effect, if used for
that purpose, several wraps are necessary.
Prices on application.
'
' Approximate Weight per 100 Square Feet
ASBESTOS PAPER:
Anproxiraate thicknessInches
6 pounds..................... ........................
....................................... 015
8 pounds.......................... ............................. ....................................... 018
10 pounds........................................................... ....................................... 020
12 pounds........................................................... ....................................... 025
14 pounds........................................................... ................................
16 pounds........................................................... ...................
.028
35 pounds........................................................... ................................
! i'o
ASBESTOS ROLL BOARD:
53 pounds............................................................ ................................ 68 pounds............................................................ ................................
&
%
47
/-
For use when insulating material of minimum thickness is required.
CRMC-003411
Johns-Manville Service to Railroads
What Insulation Efficiency Means
The efficiency of insulating material is ex pressed by a percentage, which is the percent of heat saved by using the insulation, as compared to what would be lost if no insulation were used and the surface left bare or uninsulated.
The efficiencies of all insulations vary accord ing to the temperature difference between the
surface and the surrounding air, as well as ac cording to the thickness of the insulation.
Complete information regarding the use of efficiency tables, with example to illustrate will be found on page 248.
For table showing the total heat lost from bare surfaces, see page 249.
EFFICIENCIES OF JOHNS-MANVILLE ASBESTO-SPONGE FELTED SHEETS AND BLOCKS
Thickness cf Insulation
1" ..................................
l'A".................................. 2 ".................................. Z`i"..................................
3 "..................................
..........
.......... .......... ..........
50
82.90%
90.64 92.36 93.54
Temperature Difference between Hot Surface and Sui rounding Air
100
84.17 88.77 91.32 92.92 94.02
150
85.42% 89.67 92.00 93.46 94.49
200
250
300
350
Per Cent. Efficiencies
86.50% 90.44 92.61 93.96 94.91
87.50% 91.15 93.12 94.39 95.25
88.38% 91.78 93.61 94.79 95.59
89.26% 92.40 94.10 95.19 95.92
400
90.10; 92.98 94.55 95.55 96.23
450
90.92% 93.56 95.00 95.91 96.54
50Q
91.73; 94.14 95.44 96.28 96.85
EFFICIENCIES OF JOHNS-MANVILLE 85% MAGNESIA BLOCKS
Thickness of Insulation
50
.......... 80.80%
2" ........................ ----------
' 2%"....................................
91.19
... 3
................................ .: - 92.55' : -
Temperature Difference between Hot Surface and Surrounding Air
100
150
82.36 i 83.90%
87.40 1 88.53 .
90.16 . . . 91.08
91.95
92.69'
93.22
93.83
200
250
300
350
Per Cent. Efficiencies
85.20% 89.49
91.85 93.32
94.37
86.48; 90.37
92.53 93.87 94.82
87.60% . 88.70%
91.16
91.94,
93.12
93.71
94.38
94.87 ;
95.25
95.67
400
89.64% 92.65 94.27 95.31 96.06
450
90.56% 93.32 94.80 95.73: 96.40
500
91.48% 93.97 95.31 96.14 96.75
EFFICIENCIES OF JOHNS-MANVILLE THERMO FIRE-FELT SHEETS AND BLOCKS
Temperature Difference between Hot Surface and Surrounding Air
Thickness of Insulation
50.. . 100 . ; iso.0.,
200 =
250
.300 . . ... 350- ''400.' . 450
500
Per Cent. Efficiencies
l'A". i..........i-i...
2 ...............
2SA"................. ,%.,...
3 ..........
..... 78.70%. : 80.55; ' 82.30% .
83.27,'. ' 84.64
86.00 .
. 86.09 :' 87.23 - 88.37
. 88.14: . 89.08
90.02. :
83.80% 87.18 . 89.39
90.92
85:10% 88:20
90.27 91.66
86.27% 89.14 91.03
92.33
87.42% . 90.08
91.79
93;00 '
86.48% 69.50%
90.92
91.73 ,
92.48
. 93.17 -
93.57 . .. 94.17. -
90.60%'
92.51
93.82 94.72 .
The above efficiencies'.are. b'ased.on the :a'pplicatiori'df sheets to flat surfaces. .. They. are,.approximately, correct however, for Curved', surfaces, curved ' to - taTge radius, such" as' boiler drums, tank's, etc.-
What is the efficiency of Asbesto-Sponge Felted In sulation .3" thick to be applied, bn a surface at a tem perature-of 450 F. in a room where temperature is 70 F.?
The temperature difference is 450 F.---70 F.=380. Refer to table of Efficiencies for Asbesto-Sponge Felted Insulation (on this page). Efficiency for
400 F. temperature difference is........... 96.23% 350 F. temperature difference is........... 95.92%
Difference for 50.... 0.31% If difference for 50 F. is .31% then for 1, difference is .31% + 50 = .006%. The difference (380) is 30 more than 350, so 30X.006%--.18%, which added to 95.92%*=96.1%; the required efficiency.
To find exactly how much heat is saved by applying this insulation, proceed as follows:
Refer to table giving total heat loss in B.t.u. per square foot of bare surface (page 249).
Under temperature difference of 400, you find loss is 1614.0 B.t.u. per hour, and under 350 difference loss is 1269.4. The difference in loss for the 50 difference is 1614.0--1269.4=344.6 B.t.u., and for one degree dif ference it is 344.6^-50=6.89 B.t.u.
The difference you have (380) is 30 more than 350, so 30X6.89=206.7 B.t.u., which added to 1269.4=1476.1 B.t.u., the required total heat loss from one square foot of bare surface per hour.
Having obtained the loss for bare surface, the saving effected by the 3" Asbesto-Sponge Felted Insulation is obtained by multiplying the total loss, 1476.1 B.t.u., by the efficiency of the insulation previously found (96.1%) or 1418.4 B.t.u. saved per square foot per hour.
This result may be compared with the quantities of heat saved by other forms or thicknesses of insulation, which quantities may be obtained in similar manner to the above.
48
CRMC-003412
ii
Johns"Manville Service to Railroads
Johns-Manville Sheet and Block Insulation
Approximate Weights and Standard Sizes
Material Asbesto-Sponge Felted Sheets and Blocks
Standard Sizes
Lbs. per Thickness Sq. Ft. x 36", Per inch of thickness--3.5
85% Magnesia Blocks................................................
' x 36", Per inch of thickness--1.4
Vitribestos Sheets ..................................................... ........... 36"x 72" ...........
............... /"
.88
i
36"x 72" ...........
............... 3Z"
1.3
36"x 72" ...........
............. 1"
1.8
36"x 72" .........
............... w
2.2
36"x 72" .........
............... 1/2
2.6
36"x 72" ...........
............... 2"
3.5
36"x 72" ...........
................ 2Vz"
4.4
36"x 72" ...........
............... 3"
5.3
Thermo Fire-Felt Sheets..:........ .. Vitro Fire-Felt Sheets......... . J...:.. . . . .
24" x 36" and 6" x 36"......... .............
24" x 36" and 6" x 36"......... ............... 24" x 36" and 6" x 36"......... .............
24" x 36" and 6" x 36" ......... ............... 24" x 36" and 6" x 36" ......... ............... 24" x 36" and 6" x 36"......... ........... . 24" x 36" and 6" x 36"......... ........... 24." x 36" and 6" x 36" .... .........
*/"
3Z" 1"
1/" 1/" 2" 2/" 3"
V 24"X 36" ......... 24"x 36" .........
............. 1/" .......... 2"
. . 24" x 36" .......... : 24" x 36" ..........
1/" 2",-..
1.2 1.8 2.3 2.9 3.5 4.4 6.2 7.0
3.5 4.5
3.8 4.8
Improved Asbestocel Sheets and Blocks 4-Ply to the inch;;.. .>..;. .'..:.;. . .... .>36" x 36", 3" x 18 ", 4" x 18"-, 6" x 36", 1"
1.0
6-Ply to the inch.. ;..
i V . .. .... .36" x 36", 3" x 18 ", 4" x 18", 6" x 36", 1"'' '
1.3
Asbestocel-Flexible Roll Form. , Asbestos Roll Fire-Felt.. ....^
* '. .
*1
.. i .. .. ... .
i
.
36" wide in rolls of about 250 sq. ft: 1-ply .
36" "
" .``Moo '``'.MM sV?-".
36" " " " " " iob 36" " " " " " 100 tt
.W Jl tt.
36" "
" " " 100
36" " " " " " 100
/" Vs"
,25' ;
*'' -38 .59 .75: 1.2 1.5
List Prices
Asbesto-Sponge Felted, 85<~c. Magnesia, Vitribestas, Improved Asbestocel, Fire-Felt, Thermo Fire-Felt and Vitro Fire-Felt
Thickness Inches
Price per Sq. Ft.
%" ............. ........... $ .27
f-q" ................................ 27
Vs" ............. ................... 30 r ............. ................. 30 iy6" ............. ................... 34
-w............. ................. 38
Thickness Inches
Price per Sq. Ft.
13/" ........... ................... 42 1/" ........... ................... 45
is/" ........... ................... 49 1/" ........... .................... 53 17/" ............. ................... 57
2" ........... ................... 60
Thickness Inches
Price per Sq. Ft.
2TZ" 2lA" 2V&" 2lA" 25/"
23/"
$ 64
68
... ..
72
75
79
............. ................... 83
Inches
4" V/," 31/" 4"
Sq. Ft. R7
OR
49
CRMC-003413
Johns-Manville Service to Railroads
Johns-Manville Insulating Cements
OHNS - MANVILLE Insulating Ce to seal all joints between the blocks and
J ments are composed of asbestos and to provide a smooth, attractive finish or binding materials that are low conduc a surface to which canvas may be applied tors of heat or efficient insulators. They if desired.
are applied, when mixed with water, in Johns-Manville Insulating Cements are
plastic form, producing an efficient insula also especially adapted for insulating ir
tion when dry.
regular surfaces where it would be im
They are generally used as a surface fin practicable to apply sectional insulation,
ish over block or sheet forms of insulation sheets or blocks.
Johns-Manville Asbestos Fire-Felt Insulating Cement No. 302
Johns-Manville Asbestos Insulating Ce ment No. 302 is made of asbestos fibre and binding materials that have high insulat ing values. It is'easy to mix and apply, and readily adheres to hot surfaces. As : it is light in weight and high in insulating value, No. 302 is one of the most economi
cal insulating cements manufactured.
Johns-Manville Asbestos Insulating Ce ment No. 302 finishes with a hard, durable and attractive surface, and does not peel, crack or break off.
Packed in 100 pound bags.
Johns-Manville Asbestos Insulating Cement No. 400
> . Johns-Manville Asbestos Insulating- Ce- general use whre efficiency, strength and ,-ment No. 400 is a combination of asbestos durability are desired. Besides its high ..and. other; materials of high .insulating insulating efficiency, it provides a smooth, .value... It is an idealinsulating cement for ; durable finish. Packed in 100-pound bags.
Other Johns-Manville Insulating Cements
Johns-Manville manufactures and is prepared to furnish 85% Magnesia Insulating Cement, also Johns-Manville No. 364 and No. 352 Cements. The latter two
cements are not as high : in insulating value as those referred to above and are generally used where a less expensive material is required.
NOTE:--The efficiencies of insulating-cements cannot be given in definite figures because the efficiency of a given cement may vary greatly according to the manner of application, the form of the surface on which it is applied, etc. However, it may be said that for the better grades of insulating cements applied one inch thick on flat surfaces and at temperatures corresponding to average high pressure steam conditions (about 150 lbs.), the efficiencies vary approximately from 70% to 85%.
50
CRMC-003414
Johns-Manville Service to Railroads
Johns-Manville Refractories and Cement Specialties
CRMC-0034" 5
Johns-Maiwille Service to Railroads
Johns-Manville Refractory Cements
Nos. 31, 26, 32, 20, 30 and Super-Refractories Nos. 33 and 35
ODERN engineering, power plant
M and boiler room practice is respon sible for higher temperatures in the
quality or type of brick used. If only one face or surface of a brick is exposed to flame or heat the temperature may be in
boiler fire box, and greater wear and ctreeaarsed to a point far beyond what the
on boiler settings, bridge walls and baffles. brick would stand if the entire brick were
Oil burners, mechanical stokers and surrounded by heat or if even small por
mechanical draft all contribute to increase tions of the other five surfaces were ex
power plant efficiency but result in more posed. The reason is that when only one
severe boiler conditions.
face or surface is exposed, the brick con
The maximum efficiency that can be ducts the heat from that surface and there
expected by modernizing boiler equip is a uniform drop in temperature from sur
ment can be most nearly approached by faces exposed to the surfaces directly op
building settings that are tight and do not posite. If more than one surface is ex
allow air to leak through, bridge walls that posed to heat, especially a part of the four
resist the action of flame and gases and adjacent faces, that part of the brick which
baffle walls that do not allow the hot gases is surrounded becomes hotter than the
to leak through or short circuit.
balance of the brick and this difference in
The life of a fire box or furnace brick temperature causes internal stress which
setting .does not depend entirely upon the results in spawling.
Cross-sections of Fire Brick Joints
Fire Clay .joint . befote'l firing;,';.
After firing. F.ire Clay joint opehv allowing -heat to attack front sur face .and portions of sides of brick-
Johns - Manville Refractory Ce ment as mortar on the brick already
placed.
Upper brick placed and tapped down until JohnsManville Refrac tory Cement has squeezed out at
edge of joint. i
Finished "T" joint of Johtis-Manville Refractory Ce ment. After firing and vitrifying, the bending material forms a strong protection for the
joint.
Showing that when Johns-Manville Refractory Cement is used for setting up the brick, the edges of the brick are protected against the action of the flames.
It will be noted in the illustration that the Johns-Manville Refractory Cement joint is shown thicker than the customary fire day joint. This is because it has been found that a three-sixteenth inch bond of Johns-Manyille Refractory Cement gives the best results because the greatest Strength is secured with this thickness and the desired elasticity to withstand expansion and contraction of the fire bricks is obtained. The fact that a Johns-Manville Refractory Cement bond will not disintegrate, crack and fall away under heat, which is the case with fire day joints, makes it possible to use this thickness of joint.
52
CRMC-003416
Johns-Manville Service to Railroads
An example of one and four adjacent surfaces of brick being exposed to heat is a fire-brick setting in which the fire-clay or bond between the brick has given way, either on account of the bond s having melted out because of its inability to resist heat or having crumbled and fallen out on account of its inability to resist expan sion and contraction. This falling away of the bond allows heat to come in contact with parts of the four brick surfaces adja cent to the face that forms the inside of the furnace setting. (See cuts on page 52.)
The thickness of the bond between fire bricks is often reduced, sometimes to practically nothing, but this method throws all stress due to expansion and contraction upon the brick itself and gen erally causes the brick to crack;
It is obvious that the ideal refractory
bond for setting up fire bricks would be one that resists high temperatures and ex pansion and contraction without melting or disintegrating and which possesses the quality of resiliency which would allow the fire brick to expand and contract with out damage to the brick or bond.
The use of Johns-Manville Refractory Cements, which are composed of highly refractory materials, is not limited to the setting-up of brick work. When baffle walls, dampers and other molded pieces which are to be subjected to high temper atures are built with these cements, ad ditional boiler efficiency is obtained on account of the practical elimination of heat leakage. Moreover, the life of the molded pieces and dampers is greatly in creased. The use of our refractory ce ments for these purposes is explained on this and following pages.
Johns-Manville Refractory Cement No. 31
For setting. up fire brick of boilers, and all sorts of furnaces. It begins to vitrify ; at 1450 F., and will withstand the action ` of flame and:heat, without fusing or melting, to a temperature of 3100 F. This is
as high; a temperature as is usually encountered in fire boxes or furnaces.
Johns-Manville Refractory;Cement No. 31 is packed in barrels and 100 lb. bags.
Directions for applying Johns-Manville Refractory Cement No. 31
When preparing mortar made of No. 31 Refractory Cement: Mixture must be kept thoroughly mixed and free from lumps. Use as little water as possible. Depend upon thorough mixing rather than excess water to get a workable mor tar.
"Butter" or trowel cement on brick al ready placed. Then lay brick and tap un
til joint between brick is about three-six teenths of an inch thick and the cement squeezes out between edges.
Do not point up or cut off cement that squeezes out between edges, but plaster and trowel it back over the face of the joint and brick so that it protects the edges of the brick, making a "T" joint.
53
CRMC-003417
Johns-Manville Service to Railroads
Johns-Manville Refractory Cement No. 26
Possesses certain properties that No. 31 lacks and should be used where conditions require a cement with such properties.
It begins to vitrify at 900 F. and must always be used for brick settings that are to be subjected to temperatures from 900 to 1450 F., as No. 31 does not begin to vitrify until temperatures reach 1450 F.
No. 26 will withstand temperatures up
to 2600 F., so may be used where temper atures range from 900 to 2600 F.
It is stronger than No. 31, and therefore should be used in preference to No. 31, provided temperatures do not exceed 2600 F., not only for setting fire brick but also for molding into slabs, walls or pieces that are self-supporting.
Johns-Manville Refractory Cement No. 26 is packed in barrels and 100 lb. bags.
Directions for applying Johns-Manville Refractory Cement No, 26
When setting brick: Mix water with cement to get proper mortar consistency, Mixture.must.be kept thoroughly mixed and free from lumps. Use as little water as possible.. Depend upon thorough mix ing rather than excess of water to get a workable mortar.
"Butter" or trowel the cement on the brick .already placed, then lay brick on top .and tap until joint between brick is about
thick and cement squeezes out be tween edges.;
Do not pointVup ;or cut .off cement that squeezes out between edges, .but plaster or trowel it back oyer the: face .of the joint and brick,, so that it protects the edges of the brick, making a "T" joint..
When No. 26 is to be used for molding dampers, slabs, door linings, etc.: Mix
sufficient water, but not too much, until the mixture has a consistency of dry mold-
ing sand, and is absolutely and thor oughly mixed and free from lumps.
Tamp cement in mold, or in place, sol idly; then dry gradually with a slow fire till all water has evaporated. After all water has been slowly driven out, the slab or molded piece may .be subjected to tem peratures in excess of 900 F., which will vitrify, it.
Large .molded pieces should be re-im forced by surrounding /the -edges with an., iron hand or frame and by running iron bolts or rods through the slab. All such rods should be covered or wrapped with asbestos paper to a thickness of about Via"- This allows for expansion of the iron.
Johns-Manville Refractory Cement No. 32
Made for coating the face of brickwork exposed to flame and heat, and will withstand any temperatures from 1250 to 3100 F.
It may be used both as a bond between, and coating for, fire brick setting if brick
is dipped in the cement instead of applying the cement with a trowel, as Nos. 31 and 26 must be applied when used as a bond.
Johns-Manville Refractory Cement No. 32 is packed in barrels and 100 lb. bags.
54
CRMC-003418
Johns-Manville Service to Railroads
Directions for applying Johns-Manville Refractory Cement No. 32
To prepare No. 32 Cement for use, mix sufficient water with the cement to get proper consistency. The mixture must be kept thoroughly mixed and free from lumps.
If cement is to be applied to the surface of the fire-brick settings or walls, apply it with a stiff brush or broom.
If saggers or brick are to be dipped, dip each brick or sagger separately.
When setting up brick which have been dipped, rub the brick, when placed, to a tight joint.
Amount of water required for mixing can best be determined by trial, as the porosity of the brick or sagger to be coated or dipped largely determines the proper consistency. A porous brick requires a thinner mixture than one not so porous. Use a mixture that gives a coating about %2" thick.
Johns-Manville Retort Cement No. 20
Johns-Manville Retort Cement No. 20 may be used as a refractory in connection with temperatures up to 2000 F. This cement is. furnished in plastic form and sets, hard when air dried. It is; admirably adapted for patching or filling cracks be tween . boiler door frames and boiler set ting and for general use around gas works and chemical plants: wherever a cement is
required that must resist acid fumes as
well as heat. On account of its combined refractory and acid-fume-resisting quali ties it is recommended for use in setting up brick smoke stacks. Recommended for use as a Front End cement.
: Packed in 1, 5, 10, 25, 50, 100, 200, 450
and 800 lb. containers. -
v
Directions for applyi Johns-Manville Retort Cement No.- 20
This cement 3s furnished. ' in ready-c If only a portion of -the contents of the
mixed form, and can be used directly from container is used and it is desired to hold
the container.
it over for another job, cover the cement
If It requires thinning, add water gradr with a wet cloth' or a thin seal of water,
ually, mixing thoroughly as the water is replace cover to exclude air as much as
added. .
possible and store in a cool place.
Johns-Manville Refractory Cement No. 30
Adaptable for a one-piece lining in cruci ble furnaces and for general metallurgical application. It begins to vitrify at 1850F. and is resistant to temperatures up to 3000 F. Being a carbon base cement it will give best service in a reducing at mosphere. It offers excellent resistance to slags, and is recommended for patching
along the slag line. It is not highly acted upon by either basic or acid slags. Where an excess of air is admitted to the combus tion chamber No. 33 Super-Refractory should be used.
Johns-Manville Refractory Cement No. 30 is packed in barrels and 100 lb. bags.
55
CRMC-003419
Johns-Manville Service to Railroads
Directions for applying Johns-Manville Refractory Cement No. 30
Crucible Furnace One-piece Lining
Mix cement with water to consistency of moulding sand. A form made of wood or heavy 14-gauge sheet iron, well oiled, should be set inside of the furnace, allow ing space of not less than two and one-half inches between form and shell of furnace, or whatever thickness of wall is desired.
Cement should be filled in and rammed solidly. Wooden form, if used, should be burned out. Iron form, if used, should be removed carefully.
Use slow fire to evaporate all water, then temperature should be raised grad ually to the highest point.
Laying Fire Brick
Add sufficient water to make the cement between the bricks should be spread back
about the consistency of mortar. Trowel about one inch on each brick, making a
mortar on about one-quarter inch thick so that when the succeeding brick has been tapped into place sufficient cement will re
"T" joint about three-sixteenths of an inch thick, to prevent the flames from im pinging on edges of bricks.
main between the bricks to seal uneven Always mix thoroughly until free from surfaces. The cement that protrudes from lumps.:
Johns-Manville Super-Refractory Cements Nos. 3.3 and 35
Steady improvement in:methods of fuel, chemical action, and: they will not be af-
burning, melting: of metals, etc., is, largely , dected by molten yellow metals, such as
responsible for the extremely high temper- brass, br0nze,; etc.
atures that are now encountered daily; both in special process work and' even in the fire boxes of oil-burning boilers, etc.
We have produced two super-refrac tory cements which will withstand these severe conditions. They possess one of the most important qualities required of such a cement--the ability to stand up under
These cements are particularly well -adapted for use in connection with elec trical and special furnaces.
No. 33 may be used where temperatures range from 1000 F., its vitrifying temper ature, to 3300 F., the highest temperature it will withstand.
these high temperatures with compara No. 35 may be used where temperatures
tively little shrinkage. This reduces the range from 1200 F., its vitrifying temper
possibility of cracking under severe tem ature, to 3500 F., the highest temperature
peratures.
it will withstand.
Because of the character of these ma- Nos. 33 and 35 Super-Refractory Ceterials, there is very little possibility of ments are packed in 100 lb. bags.
56
CRMC-003420
Johns-Manville Service to Railroads
Directions for applying
Johns-Manville Super-Refractory Cements Nos. 33 and 35
When preparing mortar made of No. 33 or 35 Super-Refractory Cement, material must be kept thoroughly mixed and free from lumps. Use as
little water as possible. Depend upon thorough mixing rather
than excess water to get a workable mortar.
Johns-Manville PR-15 Plastic Refractory Cement
PR-15 may be used for temperatures up to 2600' F., its highest working tempera ture. This cement is furnished in plastic form and sets hard when air dried. It is recommended for patching boiler settings, baffle walls, refractory linings in gas plant and coke plant equipment, and wherever a refractory lining or wall has broken or worn away, if the thickness of the patch does not exceed 2" and if the temperature is less than 2600 F. Patches over 2" thick or for temperatures above 2600c F. must have some other 'Jdhns-Manville Refrac tory mixed with PR-15.
The addition of PR-15 gives greater strength and density when air dried and before partial vitrification, and greater adhesion, to other Johns-Manville Refrac tory Cements.
PR-15 may also be used as a mortar in setting up bricks in furnace settings, ovens or kilns, gas plant and coke plant equip ment, etc., when temperatures are not high enough to vitrify other Johns-Man ville Refractory Cements.
PR-15 is packed in 100, 250, 45G and 800 lb. containers.
Technical Data--Qualities of Johns-Manville Refractory Cements
Lowest working temperature or low
point of vitnfaction.'.. !
.
. Highe'St w.orkm'gjtemperatvtfe,... ilyVi-;.
.. Melting point'..';i
..Complete fusion (dry pow'dfer.). .. .>i(:;.
No. 20 . Retort
900:F*
2000'F .
22.5.0:F . 2250-F.
No. PR-1S
800?^ : 2600
2700 2750s.
Specific gravity:j. . ....
. 1.84 - .
Weight in lbs. per cu. ft.;-dry moulded
powdered
Approximate capacity: lbs. required for'1 setting 1,000 bricks, with !5Jrj" thick-' ness of joints............ .. .:....................
400550
'^''Approximate capacity: lbs. required per hundred sq. ft. to coat the surface of fire brick settings 5:.V' thick
2.06
450600
No! 26
No. 30
No. 31
900 1850 2600" 3000 27t)0 . 3050.. 2750 ; 3ioo
1450 3100 . 3182 .3254.
1.68
105 7.7.
1.85 116 78 ,
1.76
110
99
500650
660850
550700
No. 32
1256 3100 3146 3200. 1:77 80.1 ...
90
No. 33 . No. 35
1000= 1200
33005".' 3500 . . 3350 :: -3542 3362 .'3570,
1.65
121
103
1;6Q .121
. 100 .
670850
670850
Character
Linear shrinkage at 2250F. ''per cent of length of dry sample before heatmg............................................................
Free and combined silica content (r{ )
Free and combined carbon content (', ()
Acid
3.3^*
Acid
Semi-acid Neutral Semi-acid Semi-acid Semi-acid Neutral
2.0***
1.5
46.77
0.0
1.4 13.9 74.4
2.0
55.11
0.0
4.5
52.5
0.01
1.0
50.0
0.0
0.0
9.5
0.0
' Sets hard when air dried.
'* Quantity of No. 32 cement required for coatinq varies a great deal, depending upon the- porositv of the brick. Above quantity, 90 lbs. per 100 so. ft. of surface, is based on average conditions and when the cement and water are used in enual quantities, i. e,, 100 lbs, cement and 100 |bs. water.
*'' Shrinkage on air drjdng.
57
CRMC-003421
Johns"Manville Service to Railroads
Johns-Manville Monolithic Baffle Walls
OILER baffle walls which are not
B perfectly tight allow some of the heat-laden gases to take a short-cut from the fire box to the stack. Such escap ing gases carry away wasted fuel. Full value from the fuel burned can only be re alized with leak-proof baffle walls.
The effectiveness of Monolithic Baffle
Walls built of Johns-Manville Cement is
very convincingly illustrated in
the diagram, showing a solid
wall or slab molded to fit closely
around the tubes, with absolutely
no joints or cracks.. The leakage
of heat-laden gases, through, such
a wall is impossible, particularly
as it is built of a strong, durable
material that will resist the stress
:.arid high temperature incidental
to this service.; '
.-ft-
the boiler, whereupon the wooden forms will burn out, leaving a solid monolithic refractory baffle wall, which eliminates leakage of hot gases.
Johns-Manville engineers are available for making suggestions with regard to the application of the various Johns-Manville Refractory Cements for building mono lithic baffles in water tube boilers.
; The Monolithic Baffle Wall is constructed by first eliminating the existing wall, in case of an old boiler, and then placing wooden forms or walls four or five inches apart, where the baffle is desired. Johns-Manville Baffle Wall Ce ment, mixed to proper consistency, is then poured and tamped be tween the forms.
After the mixture has dried completely a slow fire should be started in
How Johns-Manville Monolithic Baffle Walls effectively direct the flow of the gases of combustion and eliminate "short circuiting" and heat losses.
58
CRMC-003422
Johns-Manville Service to Railroads
Johns-Manville Aertite Boiler Wall Coating
TOUGH, rubbery coating in plas
A tic form used for covering the out side of boiler walls to prevent the
Sheet or block insulation properly ap plied to boiler walls is of course the most satisfactory manner of preventing infiltra
infiltration of cold
tion of air through the boiler walls,
air into the com
and the radiation of heat from their
bustion chamber.
surfaces. However, if such insula
Cracks and crev
tion is not applied the infiltration of
ices in boiler wall
air can be elimi
settings mean
nated at a compar
lower efficiency
atively small ex
and higher operat
pense by the appli
ing costs. While many cracks are quite small they will allow sufficient leakage to lower immediately the boiler efficiency,' Cold air,,)that leaks in. absorbs .heat im-: tii - it reaches- the :teinperature of the furnace; gases' and hence wbstes heat that : would other
wise perform use ful work. It is con servative, to esti-. mate on the fol lowing basis -- if
. HOW TO TiEST/A BOILER WALL
Fasten a'squa're of cardboard having a small aperture at its' center over a woodeii. frame. By pressing, this/ frame against a boiler wall, with the edges temporarily but completely sealed by some plastic material, any leakage in this part of the boiler wall will immediately be detected by the inrush of. air at the small aperture., A candle, flame held to this aperture will be sucked in ward if there is an infiltration of air through the boiler wall. By this method, an entire boiler wall can be very
quickly tested.
cation of JohnsManville. Aertite Boiler Wall Coat ing. . .
It forms a tough, rubbery coating or blanket over the entire boiler wall setting which re-, mains tight on ac count of its adhe sive a'ri d ductile qualities. 11 i s easily applied with a trowel.
Best results are obtained by keep ing the thickness
air leakage
as near Vie" as
through boiler walls amounts to only 5% possible. Amount required for Ylg"
of the actual quantity of air required for thickness--25 to 40 lbs. per 100 square
proper combustion and high efficiency-- feet, depending upon the number and va-
1% of the fuel burned is wasted. However, riety of cracks and the way the wall has
leakage often amounts to far more than been pointed up.
507c and, figured on the above basis, the Furnished in 25, 50, 150, 300 and 500 lb.
fuel wastage is correspondingly greater, containers. Prices on application.
59
CRMC-003423
Johns-Manville Service to Railroads
Johns-Manville Leak-No Metallic Compound
CHEMICAL metallic compound
A for repairing and closing holes and leaks in iron or steel, prepared in
Johns-Manville Leak-No differs from all other compounds made for similar pur poses in that it does not adhere as a ce
powdered form and used by mixing wmithent, but amalgamates with the metal it
water to a stiff putty. It metallizes in a self and makes a permanent repair. It
few hours and becomes a part of and the will hold high pressures, will not flake off,
same color as the casting to which it is and will resist any heat, acid, gas, or oil
applied.
that iron will stand.
Johns-Manville Ferrotite Cement
A liquid for stopping up sand holes and three hours is poured out, and the casting spongy spots in castings. Ferrotite is allowed to stand two or three hours before poured into the cavity and after two or using. Excess material can be used again.
Johns-Manville FI-O Pipe Joint Cement
A powdered material which may be makes a tight and, permanent joint,
mixed with linseed oil and used for making By mixing with water it can be used as
;tight joints, for all pipe work* such as a putty for: connecting sink wastes, base-
steam, gas, water and air. .
merit plugs, bowls,hath plugs, etc.
Economical, -.non- poisonous^ stainless, : Also furnished.ready mixed with linseed,
does not cause a bad taste in water, and oil..
Johns-Manville Fireite Asbestos Furnace Cement
A strong and durable cement for setting a few hours after application. When sub-. up-and. repairing broken joints in. furnaces, . jected to heat ityitrifies without shrinking -ranges; heaters and stoves. .It is.prepared or becoming porous. It is inodorous, and. ready for use, adheres: readily and firmly effectually prevents escape of smoke, to castings and sheet metal and "sets" in gases and dust, thus insuring perfect draft.
Johns-Manville Phoenix Asbestos Stove Lining
This is a perfect substitute for, and a great improvement upon, the old style of stove-brick for making new linings and re pairing cooking stoves, ranges, heaters, etc., also for lining doors of boilers and furnaces.
It costs less than stove-brick, is always
ready for use, will conform to irregular surfaces, can be easily applied, does not easily burn out and clinkers do not tend to adhere to it. Much time, and often ser ious injury to the stove, may be saved by having Johns-Manville Phoenix Lining on hand and not being compelled to send to distant points for stove-brick.
60
CRMC-003424
Johns-Manville Packings
61
cRMC-003425
Johns -Manville Service to Railroads
Johns-Manville Sea Rings
JOHNS-MANVIUE S6A RINGS
Note particularly the flexible lip and hollow space back of it which make the action of Sea Rings
automatic^
Cross-section of stuffing box showing Sea Rings in place.
O R packing Tods- and outside packed plungers against;, steam,. water,: air, .brine and. any. other Ruid that will not attack the. materials used in their construe^ tion. Furnished inr ring form only.
Long life and service arelobtained from Sea Ring Packing.,; because, i by preventing unnecessary : pressure ; and friction be tween rod and packing, needless wear is eliminated.
Johns-Manville Sea Rings are made for
rods. or.-plungers
ih diameter or over,
providing flange or space between rod and
stuffing-box is %" or rrtore. The action of
Sea Rings is absolutely automatic. They
press against or grip the rod only when
there is a tendency to leakage through the
stuffing-box. The pressure through the
box acts on the lips of the packing and in
proportion to the pressure.
Leakage is prevented because the flex ible lip more readily conforms to rod or plunger than the inside surface of an or dinary solid packing.
Loss of time and expense due to shut downs and labor cost of renewals are re duced to the minimum, because of the dur ability of Sea Rings.
The elimination of unnecessary friction where Sea Rings are used means great economy, on account of the saving in power required to drive the apparatus. The data and curves shown on page 63 conclusively prove the economy of Sea Rings even when good packing of the ordinary type may be purchased for less.
Sea Rings assist in Packing Standard ization through the elimination of a num ber of packings for various conditions, be cause they are constructed of materials that make them the best packing obtain able for nearly all conditions encountered where rod and plunger packing is re quired.
62
CRMC-003426
Johns-Manville Service to Railroads
Saving Power by Eliminating Friction
TREMENDOUS amount of power
A is wasted in the operation of pumps, engines, compressors, etc., because
the pressure of ordinary packing on a rod
or plunger is always constant and maxi mum, irrespective of the fact that the ten dency to leakage or pressure through the packing is usually variable.
See 7ft
7" 6st
6c*
S*c
y K 5 j%
s* &wf
/S.
a> s? af ag ta a
Relative Cost of Packing and Operating with Flax and
Johns-Manville Sea Ring Packing
Rodins vtmcaJly up each space repretenu JJ0 0&.
Reading herixofitally to the sight etch ipact rprf**At ipaeci seprewnt one week
two
Description of P.ump
frjmp--GouWi Triplex Dmm by JJ* Hikr mnni'4
DnnMtiR<%P*t,hMt*mn
phagm
IlK*
diuMlef
Sud'c*' i* Vcvv?*..
Pre^hut
3S M ft*. Pmcurr.
n*i.
4Wo#--C E Thm Phut 440 Vdl.liM.P
J4*r*e--E>urliiw
vmVdr a h Irh h**d id* of eSan, th fat te spec*
iKH, **!('f ihe (1*1 peckv*,* d iri I\yi ipn xrpmcot
Pits CO.th< iRvil or$e R*i P*&-rt
c*%\ of $f *3*4 Pirt^g !'<
ifc* eec*
>N( fl*ar lhp*aciku<>nU(> o* k*U' m-
34 3 30
4* 4S 4Z 43 J* St 0-*
7*>
7-"
&*>
sst **
4Se<*i 'j
'T^e actual coat of power (in .this ease 'electric current) i* added continually 10 that*'readinCiUp\fronP'a,ny'p6int'oni the horizonla] line (he total ce*Cof,the packing and current con* 'turned for the'given period' of'operation is obtained.' EXAMPLE?--Taking the 20*Week* of Operation*, the total cost ' Where ftax w.as used Is $297,00 and where,Sea Pings were.used $326.00.;. At the end of the 29th week the cost of packing and operation would have been identical if .the. stuffing boxes had not been re-packed with flax. From lhi..time on. a net saving was effected; and oh the,aame basis at the end efthe 52nd week, the* coat of flax and,current was $738.85 and',the. ' 'cost of ea Rings and current $666:12'.
NoletThis is an actual saving of,$72.73 during a peiiod of On'e year.'
As a matter of fact, the flax packing .never lasted over six months*so that an other $20.00 had to be added at (he end of ihe_26ih week to the curve represent*, tnglhe total cost of As% packing and eorrent'consumption. iThe 'dotted line has been drawn to show that even tf the fiax p acting lasted a* year, Sea Rings effected a sotable saving aflex the 29lh week, but with the additional cost of tepacking with taxa marked net saving was effected by Sea.Rings after the 26lh week which at the and of the 32nd week, or a year, amounted to $92.73.
Note that this swing U net--that is, the saving is clear profit after the additional <oii of Sea Rings has been allowed.
3E 3? E3d 46 Ur
7JW iff
Is,
2ft
Electrical Current Consumption and Packing Costs
Following data compiled from records made during Sea Ring test at Tide Water Paper Co., as shown in the chart above.
A--It costs $40.00 to pack a triplex electricaldriven pump with good grade braided flax
for 1 year (2 packings per year at $20,00) each). See note A, page 64.
It costs $718.85 to drive the same pump with electricity for one year. (9.6 K.W. per hour, 24 hours per day--144 hours per week--7488 hours per year=71,884.8 K.W. hours, @ 1c per K.W. hour=$718.85).
63
CRMC-003427
Johns-Manville Service to Railroads
B--It costs $115.00 to pack same pump with. Sea Rings for one year. (Sea Ring packing will last longer. See Note B, below.)
It costs $551.12 to drive pump with electric ity, one year, same number of hours as above. (7.36 K.W. per hour--55,111.6 K.W. hours at lc per K.W. hour.)
Saving in cost of power to drive pump packed with Sea Rings for 1 year. .$167.73
Premium paid for Sea Ring Packing (difference between cost of Sea Rings and Flax, $115.00--$40.00) . . 75.00
Actual net saving first year accom plished by the use of Sea Ring Packing...................................................... $92.73
This is a return of more than 123% on the $75.00 premium paid for Sea Rings.
Note A--Two packings of flax a year is conservative as pump was actually packed with flax every 4 months.
Note B--These Sea Rings were in service from November, 1917, to November, 1922.
As Sea Rings lasted five years--the last four years they saved--
Eight packings of flax at $20.00 each.$160.00 67,092 kilowatt hours at lc each......... 670.92 Total additional net saving in four
years ............................................................ 830.92 Net saving first year was....................... 92.73 Total net saving for five years is... . 923.65 Also note that actual cost of Sea
Rings ($115.00) is less than the cost of 10 flax packings at $20.00 each, or $200.00
Do not overlook the fact that electrical current saved per year was 16,773 K.W. hours.
This means that the pump packed with flax consumed 30.4% more current than when packed with Sea Rings.
Sea Ring Service
T costs more to pack a stuffing-box with
I Sea Rings than with any other packing r---except some types of mechanical
Rings. Combined, the saving afforded by Sea Rings amounts to a large return on the investment.
(metallic) packing. .'%
.; = :: ; .
The life of Sea Rings depends upon the
But the: service^rendered by Sea Rings service to which they are subjected, and
makes them: the most economical packing . in drawing conclusions from test, data
to purchase andvUse.; -/
their life should, be compared to the life
of other packings used under identical con
This service is due; to - their automatic ditions.;/
vv;:f;;;%/v :
V-
action/.which reduces friction .to the mini
The saving of: power by Sea Rings is in
mum, and so reduces wbar ori 'the; packing disputable, and-; easily determined and
and power required to /dr/ive the rod back checked by measuring.-the/power required
and fortli through the packirig/
/ ;. : to drive a machine Before and after it is
Either I service alon.e^-that: of long life packed with Sea/Rings/
or that of. power- saving--^will effect suffi
See chart and data on this and the pre
cient saving to justify the purchase of Sea ceding page.
Sorne examples of service rendered by Johns 'Manville Sea Rings
Hot Water Service Outside packed boiler feed pump at American Steel and Wire Consolidated Works, Cleveland: Plungers 12" in diameter, pumping hot water at a temperature of from 210 degrees to 212 de grees against a boiler pressure of 175 pounds. Two sets of Sea Rings were in service on the above pump for five years.
Air Compressor Service A set of Sea Rings was installed at the foun dry of a large electric company in January 1919 on the high pressure rod of an Ingersoll-Rand Compressor. This compressor operates at 257
R.P.M., the greater part of the time for 24 hours a day and 6 days a week, and develops 100 lbs. pressure. These Sea Rings were replaced by new ones on March 26th, 1922, having required practically no attention during their lifetime.
Centrifugal Pump Service Sea Rings used on a Wilson-Snyder centrifugal pump operating under varying speeds, from 750 to 1350 R.P.M., at one of the plants of a large steel company have lasted nine months and over where formerly the ordinary packing used was replaced weekly, and a brass sleeve, used in the stuffing-box, replaced every two weeks.
64
CRMC-003428
Johns--Manville Service to Railroads
Directions for the installation of Johns-Manville Sea Rings
SET of Johns-Manville Sea Rings is usually
A composed of one header ring, several Sea Rings and one follower ring. (See tags at
8. After all Sea Rings are in, install last fol lower ring, so tagged, and as arranged in set when received, so as to fit properly against
tached to rings.) The number of Sea Rings used last Sea Ring.
depends upon the depth of the stuffing box.
1. Remove old packing and clean stuffing box.
2. Install first header, so tagged, and as ar ranged in set when received, so first Sea Ring will fit properly against it. See that it is pushed back so all of it is seated against bottom of box.
3. Install Sea Rings with lips toward pressure,
9. Excessive gland pressure on Sea Rings will tend to distort the shape of the rings and reduce their efficiency and life, but it is also just as important that the gland presses against the packing with sufficient force to prevent movement of the packing in the stuffing box.
or back of box, joint of each ring to be on opposite side of box from joint of preceding ring.
4. Do not pull ends of rings straight apart, but separate them sidewise to, pass over rod.. ..
5. Work two ends of rings into .box first, then, remainder of ring.
10. Packing gland nuts should be frequently inspected and always kept tight enough to prevent any movement of the Sea Rings. Such motion will cause wear on the outside of the ring, possibly twisting or cocking of the ring in the stuffing box, and eventually a.failure.;
6. See that each ring is completely seated be-
fore installing next ring;;.
11. After Sea- Rings, have .been in service their
7. Never' cut'off ends or' any. part `of tings,,
size or volume may -be reduced, to some. ex-.
which are-made toVfit tight ;against inside'of
.. tent on account:Of' wear, and if such, is the
' box.- ;
case this ^necessitates' taking up the gland.
Specifications
wFbr those ivho desire to specify by description )
' : Each 1 set of packing shall have 'inside,' outside : degrees with; the axis: of the rod or plunger
' and depth dimensions'suitable for the. rod and packed.
'.
stuffing box for which it is .intended, and is to. The design and construction of the packing consist of several packing rings and not less than must be such that its action is positive--that is, one or more than two auxiliary rings or headers. the pressure of the packing on the rod or plunger
The packing rings of each set shall be con structed of a suitable fabric and friction or rubber cement for binding the plies of fabric together, and each ring shall have a **UM formed section having a thick heel on one side and a tapering, flexible lip or tongue on the other side.
The thick heel shall be harder than the lip, which shall be flexible so as to conform to the surface of the rod or plunger which it packs.
must be dependent upon the pressure through the packing or stuffing-box and not dependent upon the pressure of the gland on the packing.
The auxiliary or header rings shall be of such construction and shape as to provide suitable seats for the first and last packing ring in the box to rest against.
The above described packing is not to be fur nished where the space between the rod or plunger and the inside of the stuffing-box is less
The end of the heel shall be beveled or molded than 3/g of an inch or where the diameter of rod
so that it makes an angle of approximately 75 or plunger is less than 3' Gf an inch.
65
CRMC-003429
Johns'Manville Service to Railroads
0
Johns-Manville Kearsarge Rod Packing
Spiral Style No. 166
Ring Style No. 150
OR packing rods where space be
F tween rod and inside of stuffing box is %" or over.
The asbestos and other materials used and the construction of Kearsarge Rod Packing make it suitable for steam or air at any temperature and pressure, which . eliminates the necessity of using several
the rubber expansion back on top and covering the block thus formed with two wraps of asbestos cloth. There is no chance, even if cover wears away, for part of the packing to get loose and work away, for the center is folded from one piece of fabric--each layer a continuation of the adjacent one.
packings for various steam and air condi When cover wears, away, the first fold is
tions. This means a minimum stock and . presented to wear, and this is as strong
the convenience of having one; packing for and durable as the cover itself, for it is
many conditions.
'
made of-the same material.
Flexibility and resiliency: rare assured: There is .no rubber cement in the block . throughout the life of;Kearsarge -on ac- . or body, which entirely- eliminates the - count of its peculiar folded block or cen .possibility of its- becoming hard by vul
ter construction, by the rubber expansion canization. In assembling, the cover is so v back: or cushion which, adds resiliency, placed . that it is impossible for it to be
: and: because ; rubber;; cement, is entirely pulled of torn away from the body in ser ' eliminated from the center; block of: the vice.
. packing.
Sizes
and smaller, furnished with a
<. Kearsarge is Constructed.- differently : twisted core instead of the folded block from other asbestos packing which may construction.
have the same exterior appearance. The Furnished in Ring Style No. 150 and
block is formed byfolding unrubbered as Spiral Style No. 166.
bestos cloth (same quality as used for the
Jfithout rubber expansion back, Ring
outside cover) back and forth, placing Style No. 15 and Spiral Style No. 16.
Kearsarge Rod Packing is packed as follows:
Ring--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights:
Under 1" 1" to 2"
2" to 3" 3" to 4" Over 4"
rod............................... rod...............................
rod............................... rod............................... rod...............................
3 pounds 5 pounds
10 pounds 15 pounds 20 pounds
Spiral--Furnished in boxes, each containing one length of packing approximately 12^ feet long.
Approximate u-eight per hundred feet of Kearsarge
Packing treated with preserving liquid and graphite
finish:
3/6"......................................................13'4 pounds y2"......................................................20 pounds
`6''......................................................32 3 1"......................................................44
pounds pounds
7 6".........................................................57 1"......................................................71
pounds pounds
66
CRMC-003430
Johns-Manville Service to Railroads
Johns-Manville Duplex Rod and Plunger Packing
Coil Style No. 371
Ring Style No. 372
OR packing rods and outside packed
Fplungers where space between rod and inside of stuffing-boxor
are high because the layers of rubber cement between the seyeraPlayers of flax fabric form waterproof walls that prevent-
over, against hot or cold water, at alt pres- leakage through the packing. .
sures and temperatures. -
_ ..
,,
Flexibility and resiliency, are assured
The. flax and rubber material used and on account of these same layers of non-
the : construction of Duplex; .Rod - and vulcanizing rubber cement and because of
Plunger: Packinglmake it- suitable, for. rod. the rubber core iri-the cente'r of the pack-
and outside-packed plunger hydraulic ing.
v
;
service.
,:v ;
. Maximum durability ..and,-efficiency; are.,
.. johns-Manville. .Duplex;: Rod and Plun- obtained because of the woven wearing
ger Packing; is extremely durable, because . surface and. because of the. resiliency or
the cover orwearing surface is made of life of the packing,, which makes the stuff-
a fabric of tightly twisted, closely woven ing-box tight with the minimum amount
flax yarn, which wears better?than the sur- of gland pressure on the packing.
face of packing braided like ordinary flax.
^ . , . '. ,,
J'
Furnished in Goil Style No. 371, Ring
The waterproof qualities of this packing Style No. 372 and Spiral-Style No. 373.
Duplex Rod and Plunger Packing is packed as follows:
Ritiu--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights:
Under 1" rod................................... 3 pounds 1" to 2" rod.................................. 5 pounds 2" to 3" rod................................ jo pounds 3" to 4" rod.................................. 15 pounds Over 4" rod.................................. 20 pounds
XIay he ortiered in sr(s In lit rod and >tud':nbov
Spiral--Furnished in boxes, each containing one length of packing approximately 121. feet long.
(`.nil--Furnished, several coils to the box, the number depending upon the size of the packing.
.Ifjpro.vuiuiU; icWtdif per hundred feet of Duplex packing treated with preserving liquid and graphite finish:
3A"............................ Vz".................. .......................... H"............................
w............................ ..........................
V%.................. i"............................ ..........................
17 34 52
pounds pounds pounds pounds pounds pounds
67
CRMC-003431
Johns-Martville Service to Railroads
Johns-Manville Mogul Coil Packing
Twisted Style, No. 193
Braided Style, No. 222
OR packing small rods, valve stems, Mogul make it suitable for nearly any
Fetc., and where space between rod, condition. It is a convenient all-aroundstem or spindle and inside of stuffing- the-plant packing, specially recommended
box is less than
or for packing condfoir packing, small rods and boxes, or for
tions such as for oils and chemicals where no rubber is desired in the packing.
Made of long fibre asbestos yarn, twisted or braided into coil form, lubri
emergency use. ;
By untwisting the strands of Style 193, many smaller sizes may be obtained.
cated and gr.aphited..: The asbestos, yarn Furnished in coil form only, on spools
..and -lubricating compound' used;in the and reels--Twisted Style No. 193; Braided
manufacture; of both braided and twisted Style No. 222.
-
MOGUL PACKING IS PUT UP AS FOLLOWS:
Sires
' and
,. . ... ._____ __ .both styles, on % lb. spo.ols, each spool in an individual carton-,'and packed 50 spools to a large-carton'.
, Sizes W'M. JA".......................................... ..........both styles, on .1 -lb. spools,- or larger.
Sizes over. y2
......... l?oth styles, on-5 lb. spools, or larger.
-
APPROXIMATE WEIGHT OF 100-FOOT LENGTHS
Si2e Inches
Approximate Weight, pounds per
100-Foot length
of Twisted No. 193
Approximate Weight, pounds per
100-Foot length of Braided No. m
Vs ........................................... ................................................
JA ....................... ................................................
lJ/4 .................................. .................................................. 314 ..................................
V/a
Vs ........................................ ^ ........................................
SA ......................
................................................ 7/4 .................................. .................................................. ................................................ 1254 .................................. .................................................. ................................................ 2454 ..................................
7 Ya 11^4
h\
CO <N
3/a ...........................................
.................................................. 30J4
Vs ........................................ ................................................ 40 l ........................................
.................................. .................................................. A2%
6S
CRMC-003432
Johns-Manville Service to Railroads
Johns-Manville Universal Piston Packing
Cross-section of Coil Style No. 33, end opened to show construction.
Spiral Style No. 34
OR packing the pistons of inside
Fpacked pumps against water, brine, air, oils and some chemicals, where
The folded construction gives Universal greater flexibility, resiliency and ex pansion in the direction desired, which
packing space is %" or over. A combina- also means longer service and less leak-
tion of asbestos and cotton fabrics folded age or slippage past the packing when the
and molded;together so as to present a pump is in service,
wearing surface of rounded shoulders of most durable material. The back and
= , The rubber cement that holds the folds
: forth folded construction of Universal o Universal together is strong and tough.
/ Piston Packings makes it superior to the
packing.is vplcaniz^d in steel molds,
laminated type of -Hydraulic packing for so
the sizes are more accurate than
the following reasons:
v-V: laminated hydraulic packing which is cut
. ...
in strips from slab stock. Due to the
As this packing is-made of continuous methods and materials, used- in construc.tr
fabric folded back, and forth,, there are no jng Universal,..it is very durable and more
separate,laminations, to work;loose from. .economical than other packings sold at a
one.. another by the side-wiping action much lower per-pound price.';
against the pump cylinder walls. Thus
; : /'VU'.
the life of this packing is longer than that , Coil Style No. 33; Spiral Style No. 34;
of any. other hydraulic piston packing.
Ring Style No. 35.
JOHNS7MANVILLE UNIVERSAL PISTON PACKING IS PACKED. AS FOLLOWS
. Coil--Furnished in .coils approximately 12 feet long,
packed several coils to the box, depending upon the size of the packing and according to the following table:
Size of Packing
.................................................... 4 coils ' ir,"......................................................... 3coils A"......................................................... 4coils lie/......................................................... 3coils
.................................................... 3 coils M v,"....................................................... 2coils z/\"......................................................... 2coils A'................................................... 2 coils 1"........................................................... 2coils
perbox perbox perbox perbox perbox perbox perbox perbox perbox
Spiral--Furnished in boxes, each containing one length of packing approximately 12 feet long.
Ring--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights:
Under 1" rod......................................... 3 pounds
1" to 2 " rod........................................... 5 pounds
2 " to 3 " rod........................................................... 10pounds
3 " to 4" rod..................
15 pounds
Over 4 * rod...........................................................20pounds
May be ordered in sets to fit piston exactly.
Approximate weights of 100-foot lengths of Universal Piston Packing:
%"........................................................................ 10.5pounds
A"........................................................................ 18.7pounds
"A"...........................................
27.1 pounds
H*........................................................................ 41.8pounds
H"........................................................................ 52.0pounds
1"................................
68.1 pounds
69
CRMC-003433
Johns-Manville Service to Railroads
Johns-Manville Universal Combination Steam Hammer Packing
Universal Combination. Rmgi Style No. 29 .<
JOHNS-MANVIULE Steam Hammer , caused by dirt and grit, because the square Packing is a combination of asbestos, rings have -a wearing surface. of rounded cotton and rubber, and is well adapted shoulders instead of laminated edges, and
'.to railroad,'and general shop service. The style of packing recommended depends upon whether the rod is round or has one
all the rings are-made of a combination of cotton and asbestos fabrics which makes them most durable. The arrangement of
or more flat sides and upon other condi- the variously formed rings makes the set
tions Which vary considerably in different particularly flexible and resilient, and the
shops.
contraction and expansion caused by in-
Steam hammer service is exceptionally termittent service are also taken care of severe on account of the unusual vibra- by this method of arrangement,
tion, accumulation of dirt and grit on
..
rods, and intermittent service, ihe lorms ^
of rings used in Universal--round, square,
'
^
J
and diagonal cut--provide for vibration. Special sets can be furnished for rods
The wearing surface resists the wear with flat sides.
70
CRMC-003434
Johns-Maiwille Service to Railroads
Johns'Manville Jewett Ring Packing
Style No. 20
Style No. 10
OR packing small rods and spaces
Fwhere rings of exact dimensions are required or desired. Made of asbes
it is impossible to make other styles of packing in such small sizes.
All Jewett Rings are molded to exact
tos, cotton or flax yarn (according to styslehape and size in steel dies, so that they
and service), Jewett Rings are intended exactly fit rod and stuffing-box for which
for packing small spaces, i. e., where the they are intended. They are made in
space between rod, spindle or shaft and several styles for different conditions as
the stuffing-box is less than Ys" ar*d where follows:
Jewett Rings
For any condition where a ring of-small crosssection ;i;s required or where a packing' with -no 'rubber in its composition is preferable ; i;: e., for some chemical solutions, etc. This style is m&de of wire-inserted asbestos yarn, braided into jack-
..ets one over another around a thin lead ribbon, lubricated, graphited and molded into ring fornu This is an ideakpacking for the-steam regulating; and overflow valve stems., of the Hancock inspir ator.
Jewett Coil, Style No. 310
This-packing is: made. of exactly the same -ma is-: furnished in coil form. Especially recomterial, arid' by tHe. same method of .Construction as; : mended for use as. a.locomotive cab cock packing. Johris-Marivilie:Jewett' Rings, Style-No. 10, but (See page 77.) . . .
Jewett Rings , Style No. 20
Only for conditions that require a ring with a small and rectangular cross-section, i. e.,^a very ' narrow flange or width and a depth or thickness several times greater, for example: 12r' inside
diameter x y outside diameter x y&" deep. Made of Asbesto-Metallic cloth, folded into tape, cut to proper length and molded into rings.
Jewett Rings Style No. 40
Especially adapted for hot water, light oils and except that flax yarn, without wire, is used in gasoline service. Constructed similar to No. 10 stead of wire-inserted asbestos yarn.
Jewett Rings, Style No. 3
For hot and cold water service. Especially de signed for packing faucets, Fuller cocks and plumbing products. This packing is lubricated with mica instead of oil, so that it will not affect
the process of nickel-plating. Made with jute center with a braided cotton jacket or cover and molded to exact size. Furnished in white finish.
71
CRMC-003435
Johns'Manville Service to Railroads
Johns -Manville Universal Rod and Plunger Packing
Coil Style No. 30
Spiral Style No. 31
Ring Style No. 32
kOR. packing rods and outside-packed plungers where space between rod arid box is ^4, of an .inch, or: more.--
steam,, air, water and various fluids, Specially adapted where a packing with. great resiliency'is required. .-
Universal Rod Packing is made of as bestos and cotton fabrics, which have been treated with rubber cements, built up together arid Wrapped around a rubber core or cushion.
THe combination of asbestos and rub
ber produces a packing with great plia bility and resiliency which is suitable for steam, air, hydraulic and various other conditions.
It is specially recommended for severe
conditions such as high pressure hydrau
lic work, service where there is a great
deal of vibration or where rods may be in
poor condition or- slightly out of align-;
ment.
"y- U.
. .r
Furnished in Coil style No. 30, Spiral style No. 31 and Ring style No. 32.
Universal Rod and Plunger Packing is packed as follows:
Coll--Furnished in coils approximately 121 J feet long, packed several coils to the box, depending upon the size of the packing and according to the following table:
J4 *--8 coils. . . . V> "--4 coils. . . . 34'"--2 coils 5if;*--6 coils....'}jr,"--3 coils. . . . 78 "--2 coils %"--4 coils. . . . % "--3 coils.... 1" --2 coils -16*--3 coils., iff,"--3 coils
Ring--Unless otherwise specified, rings will be packed in boxes containing approximately the following weights:
Under 1" rod........................................ 3 pounds 1" to 2 "rod........................................... 5 pounds 2" to 3" rod...........................................10 pounds 3 " to 4 " rod...........................................15 pounds Over 4 " rod.......................................... 20 pounds
Spiral--Furnished in boxes, each containing one length of packing approximately 121-2 feet long.
-1 .................... .................... -" ".................... .................... 1 pound,
12 ounces 8 ounces
V'.................... .................... 2 pounds, bounces y,w.................. ..................... 2 pounds, 14 ounces n.r,".................. 3/)/ " .................... 7/ "
1"......................
72
CRMC-003436
Johns-Manville Service to Railroads
Johns-Manville Asbestos Wick Packing
Furnished regidarly in y2 and ldb. balls
Johns-Manville Asbestos Wick is made in six standard styles:
Style 4195--A single strand asbestos wick for ordinary requirements.
Style 195--Canadax, commercially pure asbestos wick made of several strands twisted together.
Style 199--A wick made from pure asbestos rov ing, in single strand form.
Style 202--A pure wick made from asbestos rov ing by twisting together several strands.
Style 4199--A single strand wick made of pure asbestos.
Style 4202--A pure wick made from several strands of asbestos twisted together.
Johns-Manville Asbestos Twisted Rope Packing
Furnished SA" diameter and up, in 10, 25 and 50-lb* reels
Johns-Manville Asbestos Twisted Rope is made in four standard styles:
Style 196 -- Canadax -- a commercially pure twisted rope made up around an asbestos core.
Style 4196--A plain twisted asbestos rope for ordinary service.
Style 200--A pure rope made by twisting several strands of asbestos roving around an asbestos core.
Style 4200--A pure rope made from several strands of asbestos twisted together around an asbestos core.
Johns-Manville Asbestos Braided Rope Packing
Furnished in 10, 25 and 50-lb, reels
Johns-Manville Canadax Braided Rope Packing, Round Style No. 566, Square Style No.; 787.; Made by braiding a commercially pure asbestos jacket over a pure asbestos twisted rope core. Made an(^ larger.- Sizes }4' to % inclusive have one jacket; % and over, two jackets.
to %" inclusive have one jacket; %" and over, two. jackets.
Johns-Manville Solid Braided Rope Packing, Round Style No. 702, Square Style No. 733.- Made of commercially pure asbestos yarn, braided into jackets, one over the other, in sizes an<3 over.
Johns -'Manville Pure Braided Rope Packing. Round Style No. 857, Square Style No. 869. Made by braiding a pure asbestos jacket over a pure asbestos twisted rope core. Made and larger. Sizes
Johns - Manville Pure Solid Braided Rope Packing, Round Style No. 788, Square Style No. 873. Made of pure asbestos yarn, braided into jackets, one over the other, in sizes %" and larger.
Johns-Manville Asbestos Cord
Furnished in and ldb. balls, 5 and 10-lb. spools, 25 and 50-lb. reels
Fire and acid resisting Asbestos Cord, with strong, hard twisted strands. Especially valuable in glass and chemical works, and for suspending metals, retorts
and crucibles in contact with fire or heat,
Also used as a string packing on small
valves.
Sizes: Mu" to
in diameter.
73
CRMC-003437
Johns-Manville Service to Railroads
Johns-Manville Slip-Type Expander Ring
HE Johns-Manville Slip-Type Ex- The Johns-Manville Slip-Type Expander
Tpander Ring is recognized as one of Ring exerts, through its broad, band-like the most valuable achievements in steel jacket, a uniform pressure on the
the air brake field, during recent years, packing, prevents it from dropping away
This device has solved one of the,many from the cylinder wall and increases the
problems which have .arisen incident to life and efficiency of the leather.
' perfecting the proper functioning of . the In regard to wear, it is practically ever-
air brake. 7
. . . ...
lasting and with ordinary care in handling
It is carefully' constructed of the best will outlast other; component parts of the
cold rolled steel and English spring wire brake equipment. '
and its superiority over the ol&style, round : There are, at the present time, over one
expander ring is apparent at a glance. The million of these rings in service on all
round ring can act.at only one point---the . classes of- equipment including locomo-
heel of the cup,.providing no support what- tives, tenders, passenger and freight cars,
ever for the lip of . the cup which accord- and the device is included m the A.R.A.
ingly drops away from the cylinder wall, rules for labor and material in inter-
The result of the concentration of pressure change.
. at the heel is rapid deterioration of the cup. Prices on application.
Cross-section of brake cylinder showing action of Johns-Manville Slip-Type Expander Ring as compared
with old style ring.
74
CRMC-003438
I
Johns-Manville Service to Railroads
Johns-Manville Power Reverse Gear i Piston Packing
OR a long
Ftime the prop er packing of
factory and will outlast them all, even under the
power reverse
most severe condi
gear pistons pre
tions.
sented a serious
The Johns-Man
problem. There
ville Power Re
were two types of
verse Gear Piston
packing in general
Packing Set com
use: one a soft
prises two Style
packing; the other,
No. 82 Moulded
metal rings. Both
Packing Cups to
of these methods of
gether with . two
packing gave good s er v i c e immedi ately after being
Joh.ns-ManviHe Power Reverse Gear Piston. Packing as installed
.>
Johns- Manville Slip Type Expan der Rings. ,
installed. ! However,: the soft packing The Style No. .82 Cup is produced es
required too frequent replacement and pecially for power reverse gear service and
the metal;! rings . had the: fault Common' is moulded of asbestos cloth and a com
to alb ' metallic and semi-metallic ' pack pound which- makes' it non-porous and
ings;' that is, they sdon - caused suffi
cient wear on the cylinder wall to necessi
tate,reboringv;:';"
'"7
The development of the johns-Manville Moulded Cup-Method solved the power re verse gear packing problem. This type of packing, produced to meet the require ments of a service too severe for cast iron
equally efficient undet air or steam pres
sure.
" '
The expander': ring is of the well known
slip type which is standard for air brake
cylinders, as described oh; page 74.
This packing set is produced in a num
ber of sizes and styles to suit all types and
sizes of power reverse gear' cylinders.
We welcome the opportunity of offer
orthe numerous types of soft packing used ing our engineering service on power re
for this purpose, has proven entirely satis verse gear packing problems.
SIZES OF POWER REVERSE GEAR PACKING CUPS
i
7i/ta M'3 int a - < rc
CRMC-003439
. . 1/ *
- u . &\
Johns-Manville Service to Railroads
Johns-Manville Mallet Locomotive Packing
Style .No. 49
.Style No. 35'....
Drawings showing the .alteration of the-old type of: joint, at left, to the;., new type, at right, furnished on request..
Style No. 49
Style No. 35
ACKING :for Mallet locomotives r- Style No. 35 has been developed to meet
Pmeets possibly the hardest service the demand for better service and de, encountered i:: railroad work, and creased maintenance expense. Both the
is, of necessity, a special typ.e.
. . ^ v .u 'i- i v- '
Style No.: 49 is- in use otia majority of P^kmg and its method of application are
railroads throughout. the United States the result o exhaustive tests plus years of
and has been adopted as standard on a experience in the manufacture of packing
number: of large systems because of the suitable for the extremely severe condi-
superior service and economy it affords. tions on Mallet locomotives.
Style No. 49 and Style No. 35 are furnished for both American and Baldwin Mallet Locomotives. Style No. 49 is also used in the expansion joints on high pressure steam, receiver and exhaust pipes.
At all of our offices there are detailed drawings giving all information necessary for the proper application and maintenance of these materials. Blueprints of these draw ings and prices of packing will be gladly sent on request.
76
CRMC-003440
Johns-Maiwille Service to Railroads
Johns -Manville Special Combination Air Pump Packing
Air End Style No. 55
Steam End Style No. 15
OR the safe and efficient operation of
F a locomotive, compressed air is not only highly important and necessary
The construction of each individual set that is intended for the air end is different from that intended for the steam end and
but also, most vital. Compressed air cathne packings for the air ends, and steam
only be produced through the expenditure ends are packed respectively in separate
of that valuable agent--steahi. Obviously, cartons, each carton marked for the end of
then^, the packing used on locomotive air the pump for which it is intended.
pumps on both steam and air ends of the rods should be the most efficient available. To this end, realizing full well that the best , results would be obtained by treating the air and steam ends;as two entirely differ ent packing problems and not' attempting
The packing for the'air end is a combi
nation of asbestos yarn and copper wire
formed into rings which are thoroughly
'
lubricated, sures and
and which will withstand pres temperatures incident to this
service without becoming hard and brittle.
to make one style of'packing serve for two
purposes, we .have developed Johns-Man-.. The packing for the. steam end is made
ville Special Combination Air Pump Pack of asbestos fabric thoroughly, lubricated,
ing---designed to' meet the most severe formed, cut and pressed to proper size and
conditions .encountered in , this service.
is admirably adapted to steam end service.
LIST OF SIZES
Style No. for Air End
1055 1155 1255 1355 2155 1255 1555 1655 1755
Style No. for Steam end
1015 1115 1215 1315 2115 1215 1515 1615 1715
......... ......... .... ....
......... ................................. For ......... ......... ......... ..................................For
6-inch Westinghouse Air Pump 8-inch Westinghouse Air Pump 81^-inch Westinghouse Air Pump 91^-inch Westinghouse Air Pump
11-inch Westinghouse Air Pump Nos. 1 and 2 New York Air Pump
No. 5 New York Air Pump No. 6 New York Air Pump
(Prices on application)
78
CRMC-003442
Johns-Manville Service to Railroads
Johns-Manville Moulded Air Pump Packing
Johns-Manville Keystone Air Pump Packing
OR packing the rods on the steam
Fand air ends of air pumps.
OR packing the rods on the steam and
Fair ends of Westinghouse and New York Air Pumps.
Each individual set of Johns-Man-
Each individual set of Johns-Manville
ville Moulded Air Pump Packing consists Keystone Air Pump Packing consists of a
of several convex and concave rings, the pair of Johns-Manville Moulded Concave two end rings of the set being shaped to and Convex Rings on each end of which is
fit the packing gland and the bottom Of placed a No. 10 Jewett Ring, bevelled to
the stuffing box, respectively.
fit the bottom of. the stuffing box and the
The rings used, in this type of packing packing gland.
are made of asbestos fibre and a suitable
The Johns-Manville Special Moulded
binder. 'This mixture is cured and mould- : Rings are made of asbestos and a suitable
ed to the proper sizes and shapes, steel binding material-which, when cured and
moulds being used.
pressed to shape and size in steel molds,
Our experience in making this material has enabled us to develop an air pump packing, which, is yery 'dense and yet re silient. The method of assembling the sets---i. e., convex and concave rings--in sures a tight fit against the rod and also against the inside of the stuffing box.
make a hard and resilient ring with great density. They are built to resist high pres sures and Severeservice,
The moulded Jewett Rings on each end of the set are made of asbestos yarn thor oughly lubricated, braided to. proper size and pressed into steel molds of exact shape and size. These-rings are softer than
Johns-Manville Moulded Air Pump the Special rings and not only conform
Packing is especially adapted to conditions readily to the shape of the stuffing box
where there is considerable lubrication.
and packing gland but provide for proper
lubrication.
LIST OF SIZES
LIST OF SIZES
Style No.
404--For
6-inch Westinghouse Air Pump
400--For
8-inch Westinghouse Air Pump
440--For 854-inch Westinghouse Air Pump
544--For 954-inch Westinghouse Air Pump
4444--For 1054-inch Westinghouse Air Pump
440--For
11-inch Westinghouse Air Pump
168--For Nos. 1 and 2 New York Air Pump
268--For
No. 5 New York Air Pump
368--For
No. 6 New York Air Pump
______________________ Prices r;n
Style No.
300--For 700--For 800--For 600--For 2100--For 800--For 900--For 1000--For 1100--For
6-inch Westinghouse Air Pump 8-inch Westinghouse Air Pump 854-inch Westinghouse Air Pump 954-inch Westinghouse Air Pump 1054-inch Westinghouse Air Pump 11-inch Westinghouse Air Pump Nos. 1 and 2 New York Air Pump
No. 5 New York Air Pump No. 6 New York Air Pump
Prices im a|>f>//i:tini>ii
79
CRMC-003443
Johns-Manville Service to Railroads
Westinghouse and New York Air Pumps
Cross section of typical stuffing box, identifying the dimensions given in
the table below:
DIMENSIONS OF STUFFING BOXES AND SCHEDULE OF PACKINGS
. . ..WESTINGHOUSE PUMPS
NEW. YORK PUMPS
.
SIZE' OF PUMP - d7 .8":, 834"-,
1.0 >2" ,11" No, 1 No.,2 No. 3 No. 4 No: 5 No. 6 , g.,, 834" -934" 11"
A- :nr
B
O mu his"
D im: ln4i
E. -W V F. , ........ V... Hr'
No. of Stuffing Boxes per Pump ` 2 -
2
Depth of Pack'g m"
r/r 13,''
2?*" 24c"
1.34" mk"
16 "
'Hr
- '32 " .. he"
4V 2 12&' m*
2" 2>V' 134" ;21^" "if"
7 J, "
4 I-3-;:"
IK" 134" lK" l.M"
2*16" 2" 2"
2" '
134" .134". 134" 134"
1-ik." w< 1%" i??6r
Hie' 'hr W
%" hV' 34c" nr
2 4 " ;4 '' 4i2K2" . T'To'"' 1M5e/ w lV|V'
nr - l Vo" l?s" l?'s"
2" '
2!4" 2vr
ur 134" 134" 11-16 "
vur 1%"- im" 1
'Hr W %" ;'W .nr. 9'3/2,,". .>32., . ?'l6"
4 V. 4''. 4" 2 I'Sfc' 1 25^'" v-nr i.H"
iw
2?v 134" 1236" w
7 .V >32
4' 1%"
nr nr
23-f6" 2?-16"-
1 nr .1)2'' wr l2^"
'Hr j3r6"
nr Hr
2 134"
2
o
Keaisarge No. 15...
.
4
4 4 4
4
44
4
4 ' ' 4: 4 "4' ' 4
4
4
4
PQ Combination
15-55 ......... 4.. 4
4
4
4
44
4 . 4 : .4'.. 4 - 4 4
4
4
4
w Keystone .. . 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
c 44 4 4 4 44 4 4 4 4 4 4 4 4 4 P3 Moulded . .. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Kearsarge No. 15... .
(A Combination No. 15
& Steam End c3 Combination z No. 55 Air 4)
w
Keystone
...
Moulded . . .
475
1015
1055 300 450 404
775
1115
1155 700 750 400
875
1215
1255 800 550 440
675
1315
1355 600 650 544
2175
2115
2155 2100 2150 4444
875 975
1215 1515
1255 800 550 440
1555 900 950 168
975
1515
1555 900 950 168
975
1515
1555 900 950 168
975
1515
1555 900 950 168
1075
1615
1655 1000 1050 268
1175
1715
1755 1100 1150 368
775
1115
1155 700 750 400
875
1215
1255 800 550 440
675 875
1315 1215
1355 600 650 544
1255 800 550 440
80
CRMC-003444
Johns -Manville Service to Railroads
Johns-Manville Kearsarge Locomotive Throttle Packing
Johns-Manville Universal Locomotive Throttle Packing
Style No. 15
Style No. 32
OHNS - MANVILLE Style No. 15 Johns-Manville Style No. 32 Universal
J Kearsarge Locomotive Throttle Pack Locomotive Throttle Packing is especially ing is the same as Style No. 150 Kear designed and adapted for high pressure, sarge Rod Packing, as described on Pagehigh temperature service, a statement
66,' except that it does,not have the rubber' which can be confirmed by an examination
expansion back, which,is usually found in of the throttle packing test records of a
high pressure packing.
number of railroads.
V This packing is made of.asbestos fabric,;
formed, cut and'tnpulded to proper 'sike. ; Since the advent of the larger locomo
All rings are thoroughly lubricatedi: Be tives and also where superheated steam is
cause of -the Johns-Manvilie method.: of . encountered, this particular packing has
-manufacturing and folding the fabric arid met the most severe requirements, giving
lubricating it, the. packing is more resili the maximum length of life. Th fact,
ent and durable than other rod packings, ' it is possible with this particular type of
.and is exclusively used on a great many packing to have one set remain in service
of the leading railroads.
from shopping to shopping of engine. It
is especially efficient where engines are
This packing is made from the best pooled, this being possibly the most dif
heat-resisting materials and therefore does ficult situation to handle with any other
not become hard in the stuffing-box.
type of throttle packing.
It is especially efficient where there is
considerable condensation, a condition that is very difficult to handle satisfac torily with other types of throttle packing.
Furnished in sets to fill the stuffing box exactly and when placing orders for this packing care should be taken to see that
Made in sets to fit stuffing-box accord the exact diameter of the rod, the inside
ing to exact diameter of rod, inside dia diameter and depth of stuffing box are
meter and depth of stuffing-box, as given. given.
81
CRMC-003445
Johns-Manville Service to Railroads
Johns-Manville Pump Packing Recommendations
Use JOHNS-MANVILLE SEA RINGS for all Rods and Outside Packed Plungers. They are the BEST PACKING for the following rea sons: 1. They save pouer, because they are absolutely auto
matic in action and the pressure of the packing on the rod is proportional to the pressure through the stuffing box. For this reason, the packing grips the rod only when there is a tendency to leakage and in proportion to the tendency to leakage. 2. They provide Packing Standardization--the elimina tion of various types of packing for different condi tions, because they are constructed of such materi als and so designed as to be the best packing obtain able for nearly all conditions. 3. They last longer than other packings because they are designed to operate automatically and are subject to pressure and wear only when necessary to pre vent leakage. The materials used are the best ob tainable.
For the BEST RESULTS pack pumps as follows:
~~~ea
B--Sea 0___5ea p
[ Except where rod or plunger is under 54"
Rings I diameter or space between rod and stuffing box
RinBSf *s less than ?$", in which cases use Mogul
Riii ns I
Twisted No. 193, Braided No. 222.
E--Universal Piston -- Coil No. 33, Spiral No. 34, Ring No. 35.
F--Pump Valves No. 206.
Packings that may be used but which are dependent upon gland pressure--the best of their class:
A--Kearsarge--Ring No. 150, Spiral No. 166.* B--Kearsarge--Ring No. 150, Spiral No. 166.* C--Duplex--Coil No. 371, Ring No. 372, Spiral No. 373.* D--Duplex--Coil No. 371, Ring No. 372, Spiral No. 373.*
* Except where space between rod and stuffing box is less than -Is", in which case use: Mogul Coil, Twisted, 193; Braided, 222.
F--Johns-Manville Rubber Pump Valves.
NOTE: For special conditions such as the pumping of chemicals, etc., consult nearest Johns-Manville office.
Inside Packed Type of Pump.
82
Vertical Outside Packed Type of Pump.
CRMC-003446
Johns-Manville Service to Railroads
Johns -Manville Service Sheet Packing
Style No. 60
OR packing parallel surfaces of
Fflanges against steam (superheated or saturated), air, water, ammonia,
oil and various acidulated and alkaline or
other chemical solutions. Johns-Manville
Service No. 60 is a sheet designed to give
satisfactory service under practically any
conditions where a sheet would be used. It has given and ivill give satisfactory service
where other sheet packings have failed.
The proper combination of Asbestos
and bonding materials thoroughly mixed
and felted together under enormous pres
sure has produced a sheet that is pliable,
resilient, adaptable to all: general work,
and which does not deteriorate with age.
This obviates the; necessity of stock
ing several sheets for different conditions, .... which not only reduces waste-and loss due
joints, wears, ionger and can be used
to deterioration but also eliminates the
' use of a wrong sheet for a; certain service, a sheet graphited on one side only are bet-
Scrap, consisting; of center and: corner ter than those cut from an ungraphited
pieces, may be saved and used at some - sheet, or, a sheet graphited on both sides,
future time, thus greatly-reducing- loss because one, side of: the gasket will stick to
due to waste. ; v
- " the flange and the other side will come
It is so dense and yet so resilient'that it -loose. This keeps the gasket in shape when
may be used in thicknesses one-half as repairs are being made so it may be used
: great as sheets of rubber 6r other materi- again, seating itself in the same place as
als. when the: joint was originally made; and
Taking into consideration the density, the sheet is also much easier to handle,
resiliency and light weight of Service
Sheet, it is more economical to use than Furnished, in standard sheets 54" x 63"
.rubber and many other types of sheet and 54" x 126" and in thicknesses of Yu",
packing sold at lower per-pound prices. V<52" and
also made
and % 2"
Surface finish--One instead of both sides thick. 3/-.2" and 1U-" thicknesses also
of the sheet is graphited. Gaskets cut from furnished in sheets 108" x 126".
SERVICE SHEET PACKING WEIGHS APPROXIMATELY:
Per square yard .......................................................................... Per square foot ............................................................................ Per square inch ..........................................................................
; " thick
5,4 lbs. lbs.
.0041 lbs.
: thick
2.7 lbs. .3 lbs. .002 lbs.
" thick
1.4 lbs. .15 lbs. .001 lbs.
83
CRMC-003447
Johns-Manville Service to Railroads
Johns-Manville Seigelite Sheet Packing
Style No, 711
A PPROVED by Underwriters' LaboraAV tories, Inc., for use against hazard
ous liquids.
For packing flanges or joints against gasoline, benzine, oil, greases, hot or cold water and air. A fibrous material that re sists the action of any of the above fluids, because it contains no rubber or rubber substitutes that are soluble in oil or gaso line. It has a very high tensile strength and when immersed in water or other fluids becomes extremely tough, resemb ling rawhide.
It is more desirable than rubber or rub ber cloth insertion sheets for hydraulic service, on account of its strength.
It is sold by the square, yard, is com paratively low in price and can be used with greater economy and efficiency than /`black oil proof" rubber sheet;/`red rub ber sheet"; : and C. I: (cloth insertion) sheet/'. The face of Seigelite sheet is ruled off with black lines into 1-iiich squares to facilitate cutting to any desired exact size without measurement.
In. general> Jqhns-Manyille Seigelite is
Seigelite Sheet Packing contains np rubber or similar materials. It assures better and more economical service fop many purposes.
recommended for: making joints on pipe flanges, gasoline, pumps, and plumbing specialties; used extensively by power .plants, mills and factories, auto repair shops, automobile manufacturers, gasengine manufacturers, the motor-boat trade, steam-fitters and plumbers.
SIZES, WEIGHTS AND LIST PRICES
Thickness
Width
Length
.01 inch ................................
Approximately48inches 25 or 50-yard rolls
inch............................................. Approximately48inches
25 or 50-yard rolls
.02 inch......................................... Approximately 48 inches
25 or 50-yard rolls
'32 inch............................................. Approximately48inches
25 or 50-yard rolls
lie inch............................................. Approximately48inches
25 or 50-yard rolls
532 inch..........................................
Sheets only, 36" x approximately 48"
5 s inch..........................................
Sheets only, 36" x approximately 48"
3ffi inch..........................................
Sheets only, 36" x approximately 48"
5 4 inch..........................................
Sheets only, 36" x approximately 48"
'ifi inch..........................................
Sheets only, 36" x approximately 48"
Approximate Weight per
Sq. Yd.
8 oz. 13 oz. lib. 1.7 lbs. 3.5 lbs. 5.1 ]bs. 7.0 lbs. 10,5 lbs. 14.0 lbs. 17.5 lbs.
List Price per
Sq. Yd.
$0.85 1.05 1.35 1.90 4.50 6.80 9.20
13.50 18.20 22.60
NOTE--The above weights are only approximate, because the weight of this material changes, depending upon the quantity 0/ moisture in the atmosphere. After a period of dampness it will weigh more than when dry.
84
CRMC-003448
Johns-Manville Service to Railroads
Johns'Manville Kearsarge Asbesto-Metallic Sheet Packing
Style No. 100
enerally used where
G surfaces are somewhat rough or uneven and where a sheet of a soft nature is there fore required. This packing is
constructed of tightly twisted asbestos yarn, spun with brass wire to give additional strength, woven into Asbesto - Metallic
J M KEARSARGE
ASBESTO-METAILIC ^ PACKING .
STYLE 5 100
"< \
_S
cloth and impregnated with Johns - Manville Heat-Resisting Compound.
Furnished in rolls 40" wide, about 250 lbs. each, in Yi-i" and 3 io" thickness. Can be furnished graphited on one or both sides, if desired.
Johns-Manville Mobilene Sheet Packing
Style No. 102
For packing gas and gasoline
J-
and impregnated with a special
engine parts;' While Johns-Mam MOBlLENE compound to withstand the high
ville Service Sheet Packing is our recommendation for. gas' engines . and garage service, Mobilene, a;
SHEET PACKING
temperatures incident to . this service. It has red compound, on one side, so that the packing will
pioneer gas -engine ' packing* is
stick to the flange when joint is
still, frequently; demanded for
broken, and graphite on the other
packing cylinder-head joints and various to allow joint to be easily taken part.
parts of gas and gasoline engines. This
packing is made of asbestos fabric of great
Furnished in rolls 40" wide, 250 lbs.
strength, interwoven with fine brass wire each; u. and ''l c thick.
Johns-Manville Liberty Red Rubber Sheet Packing
Style No. 107, without wire Style No. 108, wire-inserted
For medium or low pressure steam and hydraulic service. Manufactured from a special heat-resisting rubber compound of the highest quality, is comparatively light
in weight, and will not deteriorate rapidly,
Furnished plain or with wire insertion,
in rolls 36" wide and weighing about 200
to 250 lbs. each;
Ym" and Vs" thick.
85
CRMC-003449
Johns-Manville Service to Railroads
Johns-Manville Kearsarge Standard Asbesto -Metallic Boiler Manhole, Handhole and Tube Plate Gaskets
Better and longer service is ob tained from Kearsarge AsbestoMetailic Gaskets because of the greater strength of the unbroken round shoulder presented to the
pressure
OjR packing manhole and handhole The edges of the folds are on the inside of
Fplates of boilers. Made of Asbesto- the gasket. Metallic fabric treated with a heat-re sisting compound, and folded into severalKearsarge Gaskets may be used over
plies or thicknesses to proper size and shape. Furnished in oval form to fit plate for which they are intended. The gaskets
again if properly applied. On this account and because of their light weight, they are most economical gaskets to use.
are made so that an unbroken rounded
Furnished in Style No. 116 for man
shoulder comes 'on the outside of the ; holes, No. 117 for handholes, and No. 119
gasket which is presented to the pressure. for tube plates.. .
Johns-Manville; Kearsarge Jointless Tube Plate Gaskets
Style No, 118
For B. & W. and Heine, tube plates.
The advantage in using jointless gas
- Made, of Asbesto-Metallic fabric treated; kets for tube plate work is that there is no
with heat -.resisting compound and folded, -tape joint to interfere with perfect seat-'
into several plies or thicknesses to, proper . ing, so necessary when gaskets with a
size and shape.
very narrow flange are used.
Johns - Manville Kearsarge Jointless Tube Plate Gaskets, Style No. 118, are made seamless, without a joint, from As besto-Metallic yarn, woven into hose or tubular form and properly folded.
These gaskets are light in weight, very strong and treated with the same highheat resisting compound used in the man ufacture of Johns - Manville Kearsarge Standard Gaskets.
Directions for application of Johns-Manville Kearsarge Manhole and Handhole Gaskets
Best Tesults are obtained by placing a gasket on the manhole or handhole plate, then rubbing as much dry flaked graphite as possible on the exposed surface. The plate is then put into place. Before removing, the plate and boiler shell should be marked so that it can be replaced
in exactly the same position. If this method is followed, the gasket always seats in the same place. The graphite prevents the gasket from sticking to the boiler shell, while the ungraphited side next to the manhole or handhole plate makes gasket adhere to plate when withdrawn.
86
CRMC-003450
Johns-Manville Service to Railroads
Johns 'Manville Kearsarge Asbesto'Metallic
Gasketing Tape
OR making odd or ir
Fregular shaped gas kets to pack joints against steam, air, water, ammonia and various acid ulated, alkaline, and other chemical solutions. Made of Asbesto - Metallic yarn, woven into fabric and treated with a high-heat resisting resilient cement.
This material is gener
ally used when a softer gasketing than JohnsManville Service Sheet Packing is required, on ac count of rough surfaces to be packed.
Furnished in widths *4" and greater, and in thick ness 1/iG", Vs", 3/i6 and 14". Put up in 5 and 10 lb. rolls. Cannot be made in widths less than 1V/.
APPROXIMATE WEIGHTS PER 25 FEET OF KEARSARGE TAPE, STYLE NO. 120
Width
1 " 1 l- , . iy2. -.
" 2"
: s" Thick
................. ................... lit
..................
................... .................. 2U " ,.............
a:a:i
.........-.3*8 ;.............. 334'
.................. ......... ..
................. ....................434 . s:. .........
............. ..................5
" ...............
. -y Thick
. 1,4
...................... 2Y2 ........................3^4
.................. . .5
----- .............................................. ------ ............... ....6'4 ...,............ .. .:...............7N ........................83.4
.;................10
Thick
Johns -Manville Kearsarge Asbesto 'Metallic
Tubular Gasketing
To make manhole and handhole -gaskets in the case' of the doors of sterilizers, etc.
. for boilers in bases of emergency, or Kearsarge Asbesto ^Metallic Tubular
wherevera gasket with a round cross-sec Gasketing is packed in boxes weighing ap
tion is .required, as in the case of grooved proximately 5 lbs. or boxes weighing ap
flanges.
proximately 10 lbs., the number of I2V2-
Made by rolling the same Asbesto-Me- foot lengths per box depending upon the
tallic fabric used in the manufacture of size of gasketing. Tape and lead are
Kearsarge Standard. Gaskets into coils of furnished with gasketing.
round section with a hol
low center. This gas
keting is primarily an emergency packing, but
Approximate Weights of 12^-foot lengths.
is used quite extensively for making odd or irre gular-shaped gaskets, or for packing joints where grooves are provided for the packing to rest in, as
Style No. 124
Siae of Gasketing.
Inch
i/ "
?4
Approx. Weight
1 Pounds
1*8 2'/ 3%
87
CRMC-003451
Johns-Manville Service to Railroads
Johns-Manville Service and Seigelite Gaskets
HERE gaskets cut and ready for
Wapplication are desired, we shall be pleased to quote on application,
on sizes or sketches submitted. We are
prepared to cut and furnish gaskets from
any of our sheet packings. Inquiries should
be accompanied with complete dimensions
or sketches. Service and Seigelite are
adapted to practically any conditions and
we advise using gaskets cut from either of We recommend the ring type gasket. It makes a
tighter, better and more economical joint than the full
these materials whenever possible.
cut gasket and avoids fussing with bolt holes, etc.
Service Gaskets Style No. 61
Johns-Manville Service Gaskets No. 61 may be used for any variety of conditions,
are cut from Johns-Manville Service Standard in thicknesses of *^4",
and
Sheet No. 60, described on page 83, and 3ig".
Ring Flange Joint Gaskets Style No. 61
FOR. STANDARD FLANGES
* Size: . Pipe. Inches
O-tside D:sm., Inches
List Price, Each
3/4 . 1
2YS $0.06 2-G .09 2 .12
l;-2 . 2"
' 2^ 3
354 A
454 . 5;
61 7
8' : 9. 10 12
14' 15
m 4;S
5fi 6n
6? 8 7.;
. 754 8s y
10 -- 11 1-2*4 133* 16:
17-4 19
.15 ; .19
.28 .32 . .44 .46 . .46 .55. .62 .80 .90 1.18 ; 1.19 1.76 1.88 2.14
15
20-4
2.42
18
215g
2.2S
20
23` g
2.68
22 26 3.02
24
28*4
3.49
26
30*5
4.00
28
32-'4
4.54
30
34s g
4.70
FOR EXTRA HEAVY FLANGES
''Size Pipe.
Inches
Outside Diam.. Inches
List Price, Each
23/4 $0.11
lG 354 .14
154
2.
37/s
4Vs .
.20 .24
- 254
3
554 .30
57/s .42
355 Wz ,50
4. -
.754
.52 ; ..
4*4 734 .63 5 - 854 .75
6
.m
.97
7 11 1.13.
8
1254
1.26
9 13 1.43
10
14*4
1.62
12
16*4
2.22
14
1954
3.00
15
20 N
3.10
16
2154
3.61
18
2354
4.00
20
25*4
4.50
22
2734
4.90
24
303/8
5.76
NOTE:--The sizes given above, up to ar.d including 12 inch, are the nominal outside diameters of the pipe. Be sure that your flanges the nominal inside diameters of the pipe. Sizes above 12 inch are are standard and check with the above when ordering.
Seigelite Gaskets Style No. 712
Seigelite Gaskets No. 712 are cut from 84. Furnished in thicknesses of .01",
Seigelite Sheet No. 711, described on page
\ *02", Vvz'f */icw-
88
CRMC-003452
Johns-Manville Service to Railroads
Johns-Manville Water Gauge Gaskets
HE insistent demands for a satisfac We can also furnish water gauge gaskets
tory water gauge gasket induced us cut from Johns-Manville Millboard when
to make a study of this problem. so desired, this material also making a
It was found that the principal diffi highly efficient gasket.
culty was to obtain a packing material - The pads for the back of the gauge are which would most effectively compensate cut from Johns-Manville Millboard to the
for the difference in expansion between, same outside dimensions as the front
the glass and the metal of the gauge. Tests. gaskets.
developed the fact that; our Service sheet :packing met the requirements most suc cessfully and we accordingly proceeded
with, the manufacture: of these gaskets. Thousands of them have been placed in service and found to meet the require
The sizes shown in the table below are for the Reflex type of water gauge. We can also supply gaskets and pads for all other types of gauges.
Gaskets and pads furnished in thick
ments in every detail. They carry with nesses of I'ss" and 11 o".
them our full recommendation.
Prices on application.
89
CRMC-003453
Johns-Manville Service to Railroads
Johns -Manville
Rubber Pump Valves
Johns-Manville Cold Water Pump Valves, Style No. 416--A medium hard valve for cold water, fresh, salt or alkaline.
Johns-Manville Condenser Valves, Style No. 420--A soft, red condenser valve for lake, marine, and other severe con denser conditions.
Johns-Manville Hot Water Pump Valves, Style No. 424--A hard valve for hot water, oily and alkaline solutions. Will stand temperatures up to 250'' F.
though hard and dense, they possess the desirable quality of resiliency which makes them suitable for low-pressure as well as high-pressure conditions.
Johns-Manville Top Head and Bottom Head Gaskets for Air Pumps
Johns -Manville Pump Valves
Service Style No. 61
: Molded from a specially prepared 'grade of Asbestos Compound stock under tre mendous pressure and,at a high temper ature. ;
Style No. 206 Pump Valves will satis factorily meet almost any condition en countered in pump work. Therefore, their use eliminates the necessity of using many valves of various, densities for dif ferent conditions. Will not quick'.v de teriorate when kept in stock.
The asbestos fibre and binding ingredi ents used in the construction of these valves make them so tough that thev are practically unbreakable, and they wul not crack or chip off. Exceptional economy is afforded by the use of Style No. 206 valves on account of their life as com pared with rubber and other valves. Al
Johns-Manville .Top Head and Bottom Head Gaskets are cut from material suit able for this class of service.
Prices depend upon the size of pump for. which the gaskets are intended to be used, either New York or Westinghousen
Johns-Manville Union Washers
For packing "Standard" and "Crane" unions. These washers are designed to meet the demand for a satisfactory pack ing for pipe unions and are especially adapted for service in steam, hot water, ammonia and gas pipes. They are made of Johns-Manville Service Sheet.
Furnished Vic." or Vs" thick. When ordering Union Washers, specify whether "Standard," "Crane Standard C," or "Crane" are wanted. For "Standard" ................ Style No. 139 For "Crane"...................... Style No. 140 For "Crane Standard C" Style No. 140-C
90
CRMC-003454
Johns-Manville Car Insulation
i
91
CRMC-003455
Johns -Manville Service to Railroads
Johns -Manville Steel Passenger Car Insulation
HEN steel passenger
Wequipment was first de signed to take the place of wooden cars, several problems of design were encountered at the very outset. Could this type1 of equipment be satisfactorily heated : iit the winter ? - Could it, on- the
other hand, be made- at- all; com fortable in the; summer? Would it not be a- veritable metallic sounding board, magnifying the clatter of every crossing and the grinding of every brake-shoe?
One of the first materials sub mitted to the railroads and car builders, to solve these problems, was Johns-Manville 3-ply Sala mander Keystone Hair Insulator. This material when properly ap plied to the inside of the outside steel plates and the outside of the inside steel finish, does keep cars warm in winter and cool in sum mer, besides acting as an excel lent sound-deadener. Applied to
92
underframes, it prevents the sound of rumbling wheels, cross ing switches, and other noises from being transmitted to the in terior of the car,. It also prevents condensation from forming and settling on the side framing, as well as oh the upper and lower decks. .
This insulation consists of
three
layers of chemically
treated cattle hair fastened be
tween layers of building and as
bestos papers, with an outside
layer of muslin which allows the
material to be glued as well as
clipped to the steel plates.
Details of application of 3-ply Salamander Keystone Hair In sulator to steel baggage car.
CRMC-003456
Johns-Manville Service to Railroads
Johns-Manville Steel Passenger
Car Insulation
(Continued)
Johns-Manville Salamander is one of the most efficient insulating materials that have been tested. This high insulation efficiency exists not only at the time of installation but continues throughout years of service, as Johns-Manville Sala mander Steel Passenger Car Insulation does not rot, pack down or otherwise de teriorate.
Its application presents no difficulties whatever. It can be flanged around win dow posts, braces, carlines, purlins, up rights and any irregularities in sides, ends or roof framing, and can be curved to the radius of the decks.
Salamander Insulation is furnished in ' standard bales 3' and 4' wide, contain
ing, 200 square feet per bale. Also fur nished cut to size when so desired. ::
All car builders are familiar with Johns- Manville insulating 'materials; and rail
road companies have but to place the fol: lowing in their specifications,, to have the
material correctly used: -
Specification for Application of Johns- Manville Salamander Steel
Passenger Car Insulation
"Cars to be insulated throughout, in cluding sides, ends, upper and lower decks and underframes, with %" thickness of 3ply Salamander Keystone Hair Insulator, to be securely glued and fastened in place as shown on Railroad Company's draw ings, so as to prevent same from being dislodged."
93
Half section of Steel Car showing application of Johns-Manville Insulation
CRMC-003457
Johns-Manville Service to Railroads
Johns -Manville Ceilinite
for Steel Passenger Car Insulation
OHNS-MANVILLE Ceilinite is As-
J bestos Roll Fire Felt, as described in detail on page 45, reinforced on the back with asbestos cloth. It is used for insulating steel passenger cars, between the inner and outer shells, for fireproofing electrical apparatus such
as switch boxes, etc., or for any condition where a strong, flexible, fireproof felt is required.
Furnished in rolls 36 inches wide, 100 feet long.
A practically indestructible car in sulation; it retains its high initial
efficiency and is unaffected, by vibration or other conditions of
service
THICKNESSES AND WEIGHTS OF CEILINITE
Thickness :(
Weight per Sq. Ft.
Weight per 100 Sq. Ft.
s'.........
V'- v............ ................ v...... ........................
1 1 , lb. I7* lh.
.....................62 lb.
...................125
Ib.
. . ...................187 - Ib.
94
Half Section of Steel Passenger Car showing application of
Johns-Manville Ceilinite Fireproof Insulation
CRMC-003458
Johns-Manville Service to Railroads
Johns 'Manville Carinsul for Steel Passenger Car Insulation
it
I
A sample of Carinsul showing construction.
Carinsul is a felted cattle hair insulation, with a burlap center, backed on either side with a special asbestos covering. It is a panel form of insulation and is recom- mended for use back of the letterboard, as
its rigidity permits its use without any guard or protection against raising and lowering of windows. Furnished in %" and thicknesses, in sheets 36" x 72" or 40" x 72", or cut to dimensions required.
Johns-Manville Nycinsul for Steel Passenger Car Insulation
A sample of Nycinsul showing construction.
Nycinsul is similar in construction to Carinsul, but is not quite so rigid. It is recommended for use where a material of greater stiffness than Salamander, as described on page 92, is desired. It has been
used successfully by a number of railroads
as well as on earlier Pullman equipment,
Furnished in %" and
thicknesses, in
sheets 36" x 72" or 48" x 72", or cut to
dimensions required.
95
CRMC-003459
Johns-Manville Service to Railroads
Method of Applying Johns -Manville Insulation to Steel Cars
By Electric Spot Welding
HE simplest and least expensive
Tmethod of applying insulation to steel cars is that shown in the illus
These methods are typical and may be used in connection with the application of the Johns-Manville Insulations recom
tration herewith. This is accomplishmedended for steel passenger equipment as
by spot welding wires to the steel frame, described in detail in this section.
impaling the insulation thereon, using
either clips or tin roofing caps over the
wires and peening the ends of the wires
over these caps.
Another method of fastening is to use
channels, angles, etc. It should be kept in
mind in all designs, however, that it is es
sential that insulation be fastened, in addition to the mechanical means by
glueing to the steel sheets. This can be ac complished by the use of thick red freight
car paint, which also acts as a preservative
to the steel.
^7o Suit--4-
/Yofo
/2,"
tA/cA (TeSt/rifa
7~/}y
Sketch showing spacing of spot welded wires
7? &UFA 7V S7Z27 M/PT \S7Z7Z 'S/ZTY'T
/ 'V/'4S/Vr/f'SJ.ZtfJ}*
K \7<7 xsrssz &/&ST.
Mae, cvraw s/sts, 7*<?
G/y&Y, c>r//
*------------
96
CRMC-003460
Johns-Manville Service to Railroads
Johns-Manville Insulation for Locomotive Cab Roofs
HE reason for insulating locomotive purpose our Salamander Insulation, which
Tcab roofs is to remedy the extreme conditions of heat and cold under
is the same material that is used for the insulation of the majority of railway pass
which the engine crew in the uninsulatendger cars in service in the United States
cab must work. We recommend for this and Canada.
Specifications for Application
In applying insulation, first size it. as well as steel plate, with liberal application of thick red freight car paint.
Wires are to be spot welded to steel roof plate
as shown, on 12" to 15" centers.
annealed
wire may be used.
Salamander Insulation is furnished in bales 36"
and 48" wide, containing 200 square feet.
97
CRMC-003461
Johns -Manville Service to Railroads
Transportation of Perishables
EFRIGERATOR cars are impor Johns-Manville Hairinsul and Standard
R tant in the life of the people because Hair Felt are the oldest known refrigera ' they are used principally to carry tor car insulations and are used exten
the bulk of the nation's perishable foosdively on modern equipment.
stuffs. They are important to the railways because they are factors in the production of revenue.
It is insulation that makes the refrigera tor car possible.
Hairinsul Refrigerator Car Insulation
The ideal insulation for refrigerator cars is Hairinsul, which consists of long cattle hair, chemically cleaned and free from oils or other organic foreign matter. The hair is felted and placed between layers of waterproof paper, carefully stitched.
Hairinsul is furnished in two thick
nesses, namely %" and
and is covered
with three different weights of paper as
required -- 80, 90 and 110 pounds per
thousand square feet. The Hair Felt and
paper are stitched together with a good
quality thread, the stitches not more than 2" nor less than 1" in length and the rows of stitches are not less than 4" nor more than 6" apart.
This material is furnished in rolls, in widths up to 108" and of practically any length. It possesses all the qualities that make the ideal insulator, first, because it can be applied to refrigerator cars in one width from side sill to side plate and extending from side door around the end of car to side door on the opposite side, and second, it can be made in widths and
98
CRMC-003462
Johns-Maiwille Service to Railroads
Hairinsul Refrigerator Car Insulation
(Continued)
lengths to accommodate the dimensions of the roof structure. This elimination of joints means that it is practically applied in blanket form, and the calculation of heat conduction at any point of the car superstructure will always be the same.
There is no other material that has the same insulation efficiency, combined with
the everlasting feature of the hair itself. It can be applied en masse as shown for typical wall and roof sections for U. S. R. A. refrigerator cars, or applied against blind lining and inside and outside sheath ing. It has been used on practically all of the refrigerator cars built, and tests have indicated its superior qualities over any other form of insulation.
A
99
CRMC-003463
Johns-Manville Service to Railroads
Johns-Manville Standard Hair Felt
Refrigerator Car Insulation
OHNS-MANVILLE Standard Hair
J Felt is made of cattle hair, carefully se lected and chemically cleaned. An im proved process is used in the manufac ture, resulting in a perfectly combined felt which is not subject to disintegration. It is widely used for refrigerator car insula tion, ranking next to Hairinsul for this work. The illustration shows the applica tion of Standard Hair Felt in the recom mended thicknesses.
Standard Hair Felt is also used for the insulation of tank cars, as described on pages 101 and 102, for lining refrigerators and for insulating both hot and cold water pipes.
LIST PRICERS AND APPROXIMATE WEIGHTS
; Thickness
Price Per Sq. Ft. Weight-Per Sq.Ft.
Weight Per Bale
op.
CJ) 'MS
Ye, inch.;
4 ounces.. . 75 pounds
' ' K " . . ; -.08.
6 . " `... ......"
'. .... .10
...9 - " ...'.170
1 " . . .......... .12 .
v IK " : ............ .18
2 " . . ................ 24
12 18 " 24
..,225.
. . ..337-
____ 450
":
Refrigerator Car Insulation
Other Johns-Manville Refrigerator Car Materials
REFERITE--Used for waterproofing of floor insulation.
ASPHALT SATURATED FABRIC-- Used inside of outside sheathing and out side of lining, and as waterproofing fabric at floor line.
ROSIN-SIZED SHEATHING--Used for lining floors and walls.
ASBESTOS SILL COVERING--A brine-proof and acid-proof material used as sill protection in refrigerator, freight or stock cars.
No. 50 ASBESTOS WATERPROOF ING FELT--Used with 14 lb. Asbestos Felt and Referite as floor membrane.
100
CRMC-003464
Johns-Manville Service to Railroads
Johns-Manville Tank Car Insulation
NSULATED tank cars are constantly
I coming into more common use for the transportation of gasoline and other volatile commodities.
One reason for this is that both shippers and carriers have become aware of the ex plosion and fire hazard created by hand ling these products in the ordinary tank
car which is not equipped with any means of maintaining an even temperature with in the tank and offers no resistance to ex ternal heat being conducted through the tank shell and vaporizing the liquid car ried.
The second reason for using insulated tank cars is to avoid the enormous evapor-
INSULATION FOR CLASS IV TANK CARS
. Insulation to be secured with No. 9 B. W, G. Wire. Wire on 18" centers for .Regal, 2.4" foi^Hair Felt. Note wiring on end of tank. Same method is used on
dome. Stagger all joints.
End view of insulated tank car ready for steel jacket.
101
2'PLY #G*U. -
'srtet f*jKTc Showing details of built-up insulation.
CRMC-003465
Johns-Manville Service to Railroads
JohnS'Manville Tank Car Insulation
(Continued)
ation losses which must occur in bare or improperly insulated tanks.
Tank cars are divided into classes ac cording to date of construction, kind of construction, or service for which they are to be used. These classifications are shown in the "Standard Specifications for Tank Cars, Revised 1919, Effective Feb ruary 1st, 1920, American Railroad Asso ciation, Section III, Mechanical." Class IV covers tank cars for the transportation of volatile inflammable products whose vapor pressure at a temperature of 100 de grees F. exceeds 10 pounds per square inch, built after May 1, 1917.
The insulation for Class IV Tank Cars consists bf two courses of 1" Standard Hair Felt and three courses of 2-ply Regal Roofing Felt. The insulation is applied as shown oh the \ preceding page. This method of insulation is in general use and has .been successfully, applied on a large percentage of the insulated tank cars built by. the various car builders.
"We .are: prepared; .to- furnish complete engineering information on this subject upon request. We can also supply any
desired information on the insulation of Class V Tank Cars, which are described as --"Insulated tank cars of special con struction, built after January 1st, 1918, for the transportation of liquid products whose properties are such as to involve danger of loss of life in the event of any leakage or rupture of the tank." Liquid products of this description whose ship ment has been authorized are -- chlorine and sulphur dioxide.
Another tank car insulation problem which we have studied thoroughly is the transportation of such products as hot tar and asphalt. This is a matter entirely dif ferent from the insulation of cars carrying unheated^ materials such as gasoline. No specifications or data for the insulation of hot tank cars will be given in this catalog as each problem is handled separately, the method of insulation depending on several varying factors, such as loading temperature, temperature to be maintained, etc.
Complete information will be furnished, upon request, to cover tank cars of this type.
102 CRMC-003466
Johns -Manville Asbesto -Metallic Friction Blocks
and
103
CR^C-003467
HinfcSltm. Johns'Manville Service to Railroads
Johns-Manville Asbesto-Metallic Friction Blocks
applied to a brake band.:
OR friction brakes as. used on hoists,
F cranes, steam -shovels, /'dredges, and all Similar machinery, also for friction
Metallic Blocks is always under perfect control, as far as the brakes or frictions are concerned. \
; clutches: of Z all types,) or for any; brakingJohns-Manville Asbesto-Metallic Fric
or power transmitting duty.where friction tion Blocks, will riot char, burn or cause
material is used. Made: of selected: asbes fird, arid are practically unaffected by
tos fibre, brass or .copper: wire,- and a spec moisture, heat or oily surfaces.
ial binding compound,: densely Compacted The high friction co-efficient or grip
together by vulcanizing, under enormous ping power of these blocks means that less
pressure in metal; molds to. the exact form effort is necessary to control the machine
required.
on which they are applied than with
Johns-Manville Asbesto-Metallic Fric many other braking materials.
tion Blocks wear many times longer than The friction co-efficient of Johns-Man
wood, leather and various other materials. ville Asbesto-Metallic Friction Blocks re
Economy is effected not only on account mains more nearly constant than that of
of their durability, but by minimizing other materials, under adverse conditions,
shut-downs and reducing time and labor such as presence of oil, moisture, or exces
made necessary by replacement of other sive heat due to heavy service. This re
forms of braking materials.
sults in uniform braking action at all
These blocks grip smoothly and power times, without frequent adjustment.
fully and release quickly, yet with the Due to its high heat-resisting proper
minimum of shock to the machine to ties and resistance to wear, this material
which they are applied. Machinery can be used in smaller areas of friction sur
equipped with Johns-Manville Asbesto- face than other materials.
104
CRMC-003468
Johns-Manville Service to Railroads
Forms in which Ashesto'Metallic Friction Blocks have been furnished
secrnoN.
cra?
SECTION.
agerior*.
Description of Diagrams
Blocks Nos. 1, 2, 4,16--Types frequently used for steam-shovels, dredges, stationary hoists,
coal-dbck and mine-hoisting machinery. Blocks Nos. 8, 9. 10.--Types frequently used for multiple disc clutches and brakes. It is possible to mould Asbesto-Metallic Friction Blocks in a variety of forms for
various services.
105
CRMC-003469
Johns-Manville Service to Railroads
How and Where Johns-Manville AsbestoMetallic Friction Blocks May Be Used
KETCHES are not intended to
Sshow proper construction of clutch or brake mechanism, or of applica
tion of blocks, but only to show in gen
eral how and where our blocks may be
used.
Description of Diagrams A, B and C
Diagram A.--Typical hoisting drum with brake and friction equipment. Lever throws friction block B, on revolving gear wheel, into contact with winding drum, transmitting power from gear to drum. When unwinding, drum is stopped by forcing iron band lined with brake blocks "A" against drum. Diagram A also shows asbestos blocks used as a facing on old wooden frictions. Facings are less expensive than complete V-shape blocks. Diagram B.--Shows principle of simple cone clutch with Johns-Manville blocks used as facing. Power is transmitted from power to transmission shaft by forcing cone and facing into contact with fly-wheel. Pedal or lever controls cone. Diagram C.--Shows elementary principles of mul tiple disc clutch or brake. Discs "A" are keyed to transmission shaft; discs "B" are held to fly-wheel by slots cut in edges which fit around bolts. Power is transmitted or absorbed by forcing discs "A" and "B" together by a spring. Pressure is released by forcing spring back from, discs with lever. .
DIAGRAM A
/ICISTING'DrUM EQUIPPED WITH' FRICTION AMD , . brake- BLOCKS .
Typical Drum dkomna
.. 'arptbpelrieedblacks are.
DIAGRAM B
ContactJvr/scc of flyWheel. 3 '`Tr/ctton cone block,or facing
DIAGRAMMATIC SKETCH SHOWING PRINCIPLES
OF SIMPLE COME CLUTCH
DIAGRAM C
SHOWING ELEMENTARY PARTS OF MULTIPLE.
DISK FRICTION CLUTCH. CONSTRUCTION
DETAIL OF DISK ON TRANSMISSION SHAFT.WITM FRICTION BLOCK-/V
Sprtno & bald disks m mtasffer rwumitl*. Trsnsmisuon s'
J..Jedkn
End Ekration
"
Perspective.
SOLID ASBCSTO METALLIC brake blocks
A
Tr. Section
Elevation
Perspective
SOLID ASBESTO -METALLIC FRICTION BLOCKS b
Transmission Shaft
Disks keyed U transmission shaft
Tljrrheel^oVs
Sroores farflywhoet holts.
7r Section
Elevation
Perspectives.
ASBESTO -METALLIC BLOCKS ON WOOD BLOCK;
106
ONE HALF OF FLY WHEEL DISK B
CRMC-003470
Johns-Manville Service to Railroads
Johns-Manville Non-Bum Asbestos Brake Band Lining for Industrial Use
HERE machine de
Wsign prevents the use of blocks, we recom mend Johns-Manville NonBurn Asbestos Brake Band
Lining. Johns-Manville Non-Burn
Brake Band Lining is made of asbestos fibre spun into yarn, reinforced with wires
interwoven in each strand, and impregnated with a com pound which greatly increases its natural frict ional and wearing qualities.
Most economical because it has high gripping power and great resistance to heat and foreign matter.
Every piece of Non-Burn is stencilled with the name--look for it.
List Prices per linear foot
Furnished in two styles--Woven and Folded
NOTE.---The following, list covers widths and thicknesses usually used for machinery purposes. Folded style, can be; furnished in all sizes listed. Woven style can be furnished in . all widths listed, to and including ?f'6" in thickness.
Width1.''.
'1. *......
IX".......................
: ,IK".. : XX"....... :i'.. .a
,.:2X"....:.............
1 ;2X"..........................
:.2X"...............................
/ .3
.......... ;
3X"............................ .. 3X".........................
3X".............................. 4 *................... ; . ;
' AX"......... -.................. ,'AX".............................
AX"...............................
5 "...............................
SX"...............................
SX"..............................
SX"............................... 6 "...............................
6X"............................... 6X"...............................
6X"............................... 7 *...............................
7X"...............................
7X"...............................
7X"............................... 8 "...............................
BX"............................... 8X"...............................
BX"...............................
' Thick . Thick
Thick
$ .40 :'S U's iso'-- \ - .55 -
:so .60
: *.60. ..-.65 ''
.70
i-.70 - L-..7S 1 .;480.
. .80
-.8S : " :.9o
- `.90- . .95 1.00
; 1.00
1.05
1.10
.1.10 , l.IS - T.20
1.20 . i:25 - I-JO
' ,3.25
'1.35
1.40
1.30
1.45
1.50
1.35
1.50
1.60
1.40 - .1.55 . -1.70
1.73
1.8S
1.97
1.80
1.94 : 2.08
1.86
2.03
2.19
1.92
2.11
2.29
2.02
2.21
2.40
2.12
2.31
2.50
2.21
2.40
2.60
2.27
2.49
2.71
2.64
2.90
3.15
2.72
3.03
3.34
2.79
3.09
3.40
2.86
3.18
3.49
2.97
3.31
3.65
3.08
3.44
3.80
3.IS
3.51
3.87
3.22
3.59
3.96
3.33
3.72
4.10
3.44
3-80
4.23
3.51
3.93
4.28
:"X"
Thick
$ .70 .80 ' .90
1.00 1.20 1:30 1.50 1.60 1.70 1.80 1.90 2.05 2.20 . 2.37 2.50 2.63 2.70 2.88 3.01 3.14 3.27 3.80 3.94 4.08 4.20 4.37 4.52 4.66 4.80 4.95 5.09 5.24
Thick
$ .80 .94
1.11 1.26 1.41 1.56 1.72 1.87 2.02 2.16 2.21 2.31 2.50 2.71 2.92
3.07 3.22 3.36 3.52
3.67 3.82 4.44 4.61 4.78 4.95 5.12 5.28 5.46 5.63 5.60 5.96 6.13
X" X'f - '
. X":
H" .
Thick Thick Thick : Thick Thick
$ .96 1.16 1.35 1.54 1.73 1.92 2.12
2.31 2.50 2.69 2.88 3.08 3.27 3.46 3.65 3.84 4.04 4.23 4.42
4.61 4.80 5.00 5.19 5.38 5.57 5.76 5.96 6.IS 6.34 6.53 6.72 6.92
..$1.22' 1.48 1.73
1.99 2.24
2.50 2.76 3.013.27 3.52 3.78 4.04 ' 4.29 4.55 4.80 5.06 5.32 5.57 5.83 6.08 6.34 6.60 6.85 7.11 7.36 7.62 7.88 8.13 8.39 8.64 8.90 9.16
$1^48
1.80 2.12
2.44 2.75 ' 3.08 3.40 3.72 4.04 4.36 4.68 5.00 5.32
5.64 5.96 6.28 6.60 6.92
7.24 7.56 7.88 8.20 8.52 8.84 9.16 9.48 9.80
10.12 10.44 10.76 11.08 11.40
$1.73
$1.99
. 2:12 ' ; 2.44
->2.50 . .2.88
2.88. . : 3.33
3.27
3.78
3:65
4.23
4.04
4.68
. .4:42
5.12
4.80
5.57
5.19
6.02
5.57
6.47
5.96
6.92
6.38
7.36
6.72
7.81
7.11
8.26
7.49
8.71
7.88
9.16
8.26
9.60
8.64
10.05
9.03
10.50
9.41
10.95
9.80
11.40
10.18
11.84
10.56
12.29
10.95
12.69
11.33
13.19
11.72
13.64
12.10
14.08
12.48
14.53
12.87
14.98
13.2S
15.43
13.64
15.88
. i" Thick
$2.24 2.76 3.27
. 3:78 4.29 4.80 5.32
5.83 6.34 6.85 7.36 7.88 8.39 8.90 9.41 9.92 10.44 10.95 11.46 11.97
12.48 13.00 13.51 14.02
14.S3 15.04 15.56
16.07 16.58 17.09 17.60 18.12
(List Prices continued on next [nige.)
107
CRMC-003471
Johns-Manville Service to Railroads
List Prices per linear foot (continued]
Furnished, in two styles--Woven and Folded
NOTE.--The following list covers widths and thicknesses usually used for machinery purposes.
Folded style can be furnished in all sizes listed. Woven style can be furnished in all widths listed,
to and including
in thickness.
Width
A" . w Thick Thick
W Thick
X" Thick
'is" Thick
H" Thick
X" Thick
A" Thick
X" Thick
A" Thick
1" Thick
9 9'A".. 9'A"..
9 y**.. 10 10 A"..
lOX'-iox"-n
UX'.. UK"
UK' 12
12X"-. \1A"
12X*-13
13X"- 13X".13X"-14 '..
............ ..
14X"14X",- .............. ... ... ... . . 14X",IS
lSK". I5X"-:- ... ^
.. isx"-. 16 "..
.
16X":16X". - .*........... , ,
16X"-. 17 . ; ____
I7X"--
. . . ... . * .V..,
. 17X"-- *.*V. .**.. .i.
17X"--
18
' 18X"--
' 18X"-18X"'. 19 ......... ;
19X"19X"-.
19X"-20 ", .
20X". ........................
20X".-
20X"-. 21 "..
23X"--
21Xff..
21X*'.22 22X"--
22 y,r.
22X".
23
23X"--
23X".-
23X".24
$3.58
$4.00
$4.43
$5.38
3-69
4.13
4.57
5.52
3.80
4.26
4.72
5.67
3.87
4.36
4.86
5.81
3-94
4.42
4.90
5.96
4.05
4.53
5.02
6.10
4.16
4.64
5.13
6.24
4.23
4.74
5.24
639
4.30
4.84
5.36
6.53
4.41
4.95
5.49
6.68
4.52
5.06
5.61
6.82
4.59
5.16
5.74
6.96
4.66
5.24
5.84
7.11
4.76
5.36
5.96
7.25
4.85
5.46
6.07
7.40
4.96
5.57
6.19
7.54
5.06
5.68
6.31
7.68
5.15
5.79
6.43
7.83
5.2S
5.89
6.54
7.97
5.35
6.00
6.66
8.12
5.45
6.11
6.78
8.26
: 5.55
6.22
6.90
8.40
5.64
6.-33
7.02
8.55
5.75 6.44
7.14
.8.69
.'5.85 , . . 6.56
7.26
8.84
5:94 . 6.66 . 7.37
.8.98
6.04
. 6:76
7.48
9.12
.. 6.14
. 6.87.
7.60
.9.27
.6.24 .. 6.97 . .7.71
9.41
.6,33
7.08 . 7,83 ... .9.56
6.43 7.19
7.95
9.70
6.52 . 7.29
8.08 ' 9.84
6.60
7.40 . 8.20 9.99
6:70 -. 7151 - 8.32 : 10.13
6.80
7.61 . 8.45
10.28
, 6;90
. 7.72 ... 8,55 . 10.42
: - 7.00
7,83 ., 8.67
10.56
. 7.08
7.93
8.76
10,71
' 7.16'
8.03 . . 8.88 . .. 10,85
- 7.24 , 8:12 ' 9,01
11.00
7J2
8,23
9.13 11.14
. 7.41
8.33 , 9.25
11.28
7.51
8.43
936
11.43
7.60
8.53
9.46
11.57
7.68
8.64
9.60
11.72
7.77
8.74
9.72
11.86 '
7.87
8.84
9.83
12.00
8:95
9.94
12.15
8.04
9.06
10.07
12.29
8.13
9.16
10.19
12.44
8.23
9.26
10.30
12.58
8.32
9.36
10.43
12.72
8.40
9.47
10.53
12.87
8.49
9.57
10.6S
13.01
8.59
9.68
10.77
13.16
8.68 8.76 8.85
9.78
9.88 9.99
10.88 11.00 11.12
1330 13.44 13.59
8.95
10.09
11.25
13.73
9.04 9.12
10.20 10.30
11.36
11.47
13.88 14.02
$630
$7.11
$9.41 $11.72 $14.02 $16.32
6.47
7.30
9.67
12.04
14.40
16.77
6.64
7.49
9.92
12.36
14.79
17.22
6.81
7.68
10.18
12.68
15.17
17.67
6.98
7.88
10.44
13.00
15.56
18.12
7.15
8.07
10.69
13.32
15.94
18.56
732
8.26
10.95
13.64
1632
19.01
7.48
8.45
11.20
13.96
16.71
19.46
7.65
8.64
11.46
14.28
17.09
19.91
7.83
8.84
11.72
14.60
17.48
20.36
8.00
9.03
11.97
14.92
17.86
20.80
8.16
9.22
12.23
IS .24
18.24
21.25
8.33
9.41
12.48
15.56
18.63
21.70
8.50
9.60
12.74
15.88
19.01
22.15
8.68
9.80
13.00
16.20
19.40
22.60
8.84
9.99
13.25
16.52
19.78
23.04
9.02
10.18
13 .SI
16.84
20.16
23.49
9.19
10.37
13.76
17.16
20.55
23.94
936
10.56
14.02
17.48
20.93
24.39
9.53
10.76
14.28
17.80
21.32
24.84
9.70
10.95
14.53
18.12
21.70
25.28
9.87
11.14
14.79
18.44
22.08
25.73
10.04
1133
15.04
18.76
22.47
26.18
10.21
11.52
15.30
19.08
22.85
26.63
1039
11.72
is:56 19.40
23.24
27.08
10.54
11.91
15-81
19.72
23.62
27.52
10.72
1230 . 16.07 . .20.04
24.00
27.97
10.90
12.29 16.32 2036 ,24.39
28.42
11.07 . 12.48
16.58 . 20.68. . 24.77. 28.87
11.24
12.68
16.84 .21.00 . 25.16 . 29.32
11.40
12.87 . 17.09 ;21.32 . -25.54
29.76
11.56
13.06
17.35
21.64
25.92
30.21
,11.73
13.25 . 17.60 ' : 21.96 - 26.31
30.66-
11.90
13.44
17.86, 22.28
26.69- 31.11
12.07 '13.64
'.I8;i2 : 22.60 ' 27.08
31.56
.12.24
13.83 : 18.37 , 22.92 . , 27.46
32.00
12.40 14.02
18.63
22.24 - 27.84
32.45
12.57 - 14.21. .18.88 23.56 ' 28.23
32.90
,12.74 . 14.40 ; .19.14
23.88
28.61 33.35
12.92 ,14.60 . 19.40
24.20 , 29.00
33.80
13.08
14.79
19:65
24.52 ' ' 29.38
34.24
13.25
14.98
19.91 . .24.84 - 29.76 34.69
13.44
15.17
20.16
25.16
30.15
35.14
13.60
1536
20.42
25.48
30.53
35.59
13.76
15.56
20.68
25.80
30.92
36.06
13.93
15.75
20.93
26.12 . 31.30
36.48
14.10
15.94
21.19
26.44 . 31.68
36.93
14.27
16.13
21.44
26.76
32.07
37.38
14.44
1632
21.70
27.08
32.45
37.83
14.60
16.52
21.96
27.40
32.84
38.28
14.78
16.71
22.21
27.72
33.22
38.72
14.95
16.90
22.47
28.04
33.60
39.17
15.12
17.09
22.72
28.36
33.99
39.62
15.28
17.28
22.98
28.68
34.37
40.07
15.46
17.48
23.24
29.00
34.76
40.52
15.62
17.67
23.49
2932
35.14
40.96
15.79
17.86
23.75
29.64
35.52
41.41
15.96
18.05
24.00
29.96
35.91
41.86
16.13
18.24
24.24
30.28
36.29
42.31
1630
18.44
24.52
30.60
36.68
42.76
16.47
18.63
24.77
30.92
37.06
43.20
S18.63 19.14 19.65 20.16 20.68 21.19 21.70 22.21 22.72 23.24 23.75 24.26 24.77 25.28 25.80 26.31 26.82 27.33 27.84 28.36 28.87 29.38 29.89 30.40 30:92 31.43 31.94 32.45
.32.96 33.48
. 33,99 .. 34.50 3S.01 35.52 35.78 36.55 37.06 37.57
38.08 ' 38.60 39.11 39.62 40.13 40.64 41.16 41.67 42.18 42.69 43.20 43.72 44.23 44.74 4S.25 45.76 46.28 46.79 47.30 47.81 46.32 48.84 49.35
108
CRMC-003472
Johns-Manville Steam Traps
109 CRMC-003473
Johns-Manville Service to Railroads
The Johns'Manville Steam Trap
WNERS, superintendents arid engi- The little device that guards the outlet of
O neers give the purchase of large the coil or radiator, that should prevent - units for ' their power or- heating any steam from getting away before it has
plants the most careful consideration, but given up its heat and yet allow all
the importance of the smaller and less ex- water and air to get away and make room
pensive power-plant unit is often over- for m0re steam, is an important factor of
looked.
_ the heating system.
For example: The economical opera
tion of a plant is largely dependent upon See table showing loss due to steam
the efficiency of the steam trap used, leakage, page 252, Appendix.
Continuous Perfect Operation
of a trap necessarily depends upon the de sign of the trap and the arrangement of its parts. The Johns-Manville Trap has only three parts--the body, the discharge bushing, which screws into the outlet of the body, and the hollow, seamless copper
ball, which is free to float and move in the body.
Wear and maintenance cost naturally depend upon the number of trap parts-- especially those that move or those that are subject to corrosion.
no
CRMC-003474
Johns-Manville Service to Railroads
ACTION OF THE JOHNS-MANVILLE TRAP
When water first flows into the trap at X and begins flowing out of the discharge orifice Y, the ball (2) floats to and is held against the discharge bushing (3) by an unbalanced steam pressure.
The discharge orifice is completely sealed until the water level (W) in the trap begins to rise, then the buoyant force of the water roJJs the ball upwards on the face of the discharge bushing (3), exposing either part or the entire area of the discharge orifice (Y)--depending upon the quantity of water entering the trap at X.
When the quantity cf water entering the trap at X de creases. the level of the water drops to the point where the bait again partially or completely covers the discharge orifice Y being held tightly against the face of the bush ing (31 by the unbalanced steam pressure. In this way a water seal is provided between the steam in the top of the trap and the discharge orifice Y, eliminating all possibilty of steam leakage.
The one moving part of the Johns-Manville Trap, the ball--replaces the valve, valve stem, levers, cotter pins, springs, thermostatic parts, buckets and all other similar parts used in the construction of other types of steam traps.
The operation of the Johns-Manville Trap is positive and simple. It depends entirely upon the amount of water flowing to the trap. The ball is held against the flat surface
of the discharge bushing by the pressure
in the system.
Water flowing into the trap acts as a
force which raises or rolls the ball upward
on the face of the discharge bushing and
thus exposes part or all of the outlet ori
fice. The ball rises and falls, according to
the quantity of condensation coming to
the trap, and the flow from the trap is
regulated accordingly.
.
No Air Binding
The Johns-Manville Trap will not-.air If a trap will not discharge air or .gas as
bind" because air (heavier than steam. but ' well, as water, the air will accumulate in
lighter than water) accumulates- OriV the; the trap and system unless vented by some
surface: of the water,'which is a very`short supplementary means. The inability of
distance above the trap outlet and is dis other types of steam traps to discharge
charged with the water through small vor air ivith the water and without loss of steani
tices that form between the surface of the is due to their construction and principle
water and the outlet. We put a pet cock of operation requiring a thick water seal
on"the cover of our trap, not as an air re over the outlet of the trap to prevent the
lief, but because it is useful to show that loss of steam. Such a water seal effectually
the trap is operating properly.
prevents the discharge of air.
No Steam Leakage
is possible with the Johns - Manville Trap because there is always a thin water seal between the outlet and the steam. If the water-level drops too near the outlet
the ball also floats lower, closes the outlet and effectively stops discharge of water or steam.
ill
CRMC-003475
Johns"Manville Service to Railroads
The Johns-Manville Steam Trap
on account of its simplicity of construc tion and operation, requires practically no attention.
There are no adjustments to make--no valves to stick. Replacements or repairs seldom have to be made. In fact, there are only two parts -- the ball and dis charge bushing--that could wear.
Operation is positive and continuous, hence any machine or system to which these traps are attached is always free of air and water.
The Regular Models (made of cast iron) are suitable for all pressures. The Junior Models are made for pressures up to one hundred pounds per square inch.
*------------------- A--------------------- `
i*-----------------------------------E------------------------------------ 1
See table for; dimensions indicated.
Capacity and Dimensions
The capacities . given for pipe ; sizes
shown are average, not the ma.Yimz/ni-^as are frequently given in other capacity tables, Peak or emergency conditions fre quently require a trap to handle more water
than when operating under normal conditions so a factor'of safety should be al lowed. The Johns-Manville Trap will take care of more water than any other trap of the same size.
CAST IRON MODELS FOR ANY PRESSURE
Trap No.
Pipe Lbs. of Water Si2e, Ins. Per Hour
A
2- A........................ 3- A......................... 4- A........................ 5- A........................ 6- A......................
# 1 1# 1# 2
700 1000 1700 3S00 6000
7? jo 8# 10# 12# 14#
Dimensions in inches. (See diagram.) 8 CD
E
6 TVs 8# 11# 13
2'A 3# 4# 5H 6#
3# 4# 5# 7# 8#
6# 8 10# 12# 14#
Weight Lbs.
14# 23 47 85 126
List Price Each
$27.00 35.00 40.00 70.00 95.00
112
CRMC-003476
Johns-Manville Service to Railroads
The Johns-Manville Junior Trap
A compact trap for low, medium or high pressure services.
DEAL for small steam line drips, coils,': cover screws to the body instead of being
I indirect stacks, radiators, cooking-, bolted. This makes it extremely compact, utensils, coffee-urns, plate-warmers, The Junior, too, consists of only a body steam-tables, sterilizers, ovens, kettles, rolling ball and -discharge bushing. Disglue-pots, steam-plates, laundrymachines, : charges continuously; will not leak.steam; dryers, dressers, calenders, etc., or wher- has no complicated parts and cannot airever condensation does not exceed 250 bind.
pounds per hour.. .
Johns-Manville Junior Steam Traps are
The Johns-Manville Junior Trap is'tbie same in its principle of operation as the larger Johns-Manville Trap, the only difference being its size, the metal of which the body is made, and the fact that the
equipped with bushings for low, medium , or high pressures. Neatly finished, made, of highest grade steam metal. Pressure ranges are 1-10 lbs.; 10-30 lbs.; 30-100 lbs.; see tabulation below.
BRONZE JUNIOR MODELS FOR PRESSURES UP TO 100 POUNDS
Trap with bushings (or
Low Medium
High pressures
Pressure Range
1-10 lbs. 10-30 lbs. 30-100 lbs.
Pipe Size Inches
54
Dimensions
4%" long JC
3ys" high
Weight 23/8 lbs.
List Price Each $10.00
113
CRMC-003477
Johns-Manville Service to Railroads
The Johns -Manville Radiator Trap
A |,AHE Johns-Manville Radiator Trap Noiseless--Nothing'to vibrate, rattle or I operates on exactly the same princi-. make any kind .of noise, as the ball is the
pie as the; Johns-Manville Steam only moving part and is surrounded by a
Trap. The only, part that moves is the cushion of water.
ball--it discharges air, gas and water con- : No Steam Leakage--A thin but constant
tinuously as they come to.it and without water seal always prevents steam leakage.
loss of steam. The action of the Johns-Man- Non-Air Binding--Free discharge of air
ville Radiator Trap is positive--that is, it is. and water permits radiators to heat up
. operated directly by the water of condensa- rapidly. ''
;
tion which must be discharged from the Capacity^Not affected by variation in radiator, and not indirectly by the tern- temperature, of water discharged.
pej-ature of. the water to be discharged. Those qualities which make it superior, and so desirable to use with heating systerns are:
Simplicity Nothing to get out of order,
Finished Appearance--The shape and size make the Johns-Manville Trap an attractive t of the heating system.
The owner, arc.h.iztect. , engineer and, operator will get full satisfaction because
Durability--Nothing to wear -- repairs after installation perfect results are ob-
and replacements minimized.
tained without care or changes.
Non-Adjustable -- Nothing to adjust-- therefore no after adjustments necessary and no chance of adjustments being tarnpered with.
Steam-fitters and contractors will be relieved of all trouble after installation because of no after adjustments and a minimum of repairs and replacements.
114
CRMC-003478
Johns-Marrville Service to Railroads
For pressures up to 10 pounds--either For use on cast iron radiators only, unless gravity or vacuum systems. Furnished in ordered special. For dimensions, see op bronze or bronze with plain nickel finish. posite page.
LIST PRICES
Standard
Trap Angle
Connections
Type.. ..Vz" and
Pressure Range
Oto 10 pounds
Straightway Type........... Yz and Va"
Oto 10 pounds
Corner Type...................... . .Yz" only Oto 10
(Right and left)
pounds
Pipe Size Approximate
Inches
Weight
Finish
List Price Each
Yz" 2 lbs. 5 oz. bronze ................. $7.00
Yi" 2 lbs. 5 oz. nickel finish ... 7.50
3/a" 2 lbs. 7 oz. bronze
8.00
Yi" 2 lbs. 7 oz. nickel finish ... 8.50
Yz" 2 lbs. 3 oz. bronze ................. 8.00
Y2" 2 lbs. 3 oz. nickel finish ... 8.50
Y4" 2 lbs. 6 oz. bronze
9.00
3/4" 2 lbs. 6 oz. nickel finish ... 9.50
Yu" 2 lbs. 4 oz. bronze ................ 8.00 Yz' 2 lbs. 4 oz. nickel finish ... 8.50
How to specify a Johns -Manville Steam Trap
LL steam traps required shall be
A suitable for pressures at which they ""must operate, and must discharge
bushing. The hollow copper ball is to act as a valve to regulate the discharge from the trap, and is to be free to revolve or
,air as well as water without the aid of sep- move in any direction, having no levers,
arate air passages. All traps are to be of rods, weights or valves of any description
thd iion-attached rolling ball type, consist- attached to it. The traps are to contain no
ing of only three essential parts: body, thermostatic parts..
non-attached rolling ball and discharge
How to specify a Johns'Manville Radiator Trap
All radiator traps placed on the return side of the radiators shall have *4" connections and must discharge air as well as water without the aid of separate air passages. All traps shall be of the non-attached rolling ball type, consisting of only three essential parts, the body, non-attached rolling ball, and a union connec tion. The hollow copper ball which acts as a valve to regulate the discharge from the trap is to be the only moving part, is to act as a valve to regulate the discharge from the trap, and is to be free to revolve or move in any direction, having no levers, rods, weights or valves of any description
attached to it. The radiator traps are to contain no thermostatic parts,
No other valve will be accepted under this specification unless approved by the Architect in writing,
NOTE
If it is desired to specify Johns-Manville traps by their names, an additional paragraph should precede the other paragraphs on both steam and radiator trap specifications. This paragraph to read: "All traps shall be the Johns-Manville non-attached rolling ball type."
115
CRMC-003479
Johns-Manville Service to Railroads
The Johns-Manville Volume Meter
For the accurate measurement of boiler feed water, and other liquids
HE notable features of this meter are
Tits extreme accuracy, simplicity and durability. Constant accuracy and long life are se cured by the total elimination of fric tion between meter parts. The meter has no moving parts. It cannot wear out.
Although origin ally designed for the measurement of boiler feed water its freedom from: movihg parts makes it ideally suited for : the measurernent of many liquids such as corrosive chemicals which .prohibit the use of submerged bearingsj valves or other m ec ha n.i c al parts. . . As the meter is a purely static device and measures in fixed volumes it is equally well suited to the metering of liquids of varying viscosities and densities. It will accurately meter the volume of practically any liquid that will flow freely through a pipe or conduit.
The Johns-Manville Volume Meter con sists essentially of two tanks or compart ments of fixed volumetric capacity which are alternately filled and emptied. A
counter or chart re corder indicates the number of times the compartments are filled and emptied, thereby furnishing a record of the quantity of liquid passed through the meter.
The Johns-Man ville Volume Meter can be built for any . capacity from lab oratory size up to that required for measuring a city water supply. Its accuracy is practi cally 100%.
In boiler plants : the meter is partic
ularly adaptable for such services as the measurement of boiler feed water, make-up water, wastes from hot wells and blow-off tanks, or for the metering of condensate from power generating units. Additional information will be fur nished by any Johns-Manville Branch.
116
CRMC-003480
Johns-Man ville Asbestos Roofings
117
CRMC-003481
Johns'Mairville Service to Railroads
Johns -Manville Asbestos Roofing
A | ^HE quality of asbestos products de- The fibres extracted from the crushed
1 pends.; not only-upon , the experience, asbestos rock are graded by length and
.? skill- and equipment of the manufac strength. For roofing fabrics we select
turer, but also upon the quality of the raw that grade of fibres which gives uniform
material. Since asbestos fibres vary, the ity of texture and the highest tensile
correct grading and selection is absolutely strength. For built-up and ready-to-lay
necessary.
roofing these fibres are fabricated by spec-
. ial machinery into strong compact felts,
Controlling every step from mine to which in turn are thoroughly impregnated
market, combining the facilities of the with natural asphalts. The felts are then
miner with the expert knowledge of the cemented together with hot asphalt either
manufacturer, Johns-Manville has excep on the roof (for built-up roofing) or at the
tional opportunities for discriminating in factory (for ready-to-lay roofing).
the selection of asbestos fibre for JohnsManville Asbestos Roofings.
There is no roof built--flat, monitor, saw-tooth, or special design--to which
This in itself is a definite manufacturing Johns-Manville Asbestos Roofing in one
advantage.
form or another cannot be applied.
118
CRMC-003482
Johns-Manville Service to Railroads
Johns 'Manville Roof Registration
And What It Means to the User
ffMlIllliftm
.A.I.'S
nmisTEii mis nmmyo
'W1XXI OHOM12ST
>//., f/., /f //S'*/,///y //'t /fry1'r/rrf/s*//'.,
/>// //j'.s //-//// ,s?/'/ /"//f /.'*//'*/ ''`///'Y/
. ________
SyO"sYZ/tf."s///>'///............... ..........................................
yiW/TJ sy/..____
- Z//yZs,,y rs/s/t//
// ///YZ- ////</ Zf'Yf/rs/"/
JOHXS->rAXVSI/L>: Jxr.. Exccurivt offices.- fov vo&k
CANAOI<\N J<
---Lf'yj'-y'S'g.a > 'r
v ie sf *? -<ti; n-a
. CO..LTt M A y x x. v g . > srti=->--.gs-g .
A fac-simile reproduction of. the Johns-Manville Roof Registration blank.
N addition to a formal written guaran
I tee for "a, specified number, of years, which is the usual manner in which a
accidents, abuses or unusual condition ex isting at the time. .
In this way we assume the entire re
roofing. ^manufacturer vouches for thesponsibility for the performance of , our
service value of his material, Johns-Man materials and see-that every Johns-Man
ville offers -a still broader protection; ville roof owner* obtains the full service
through its plan of roof registration.
from his roofing that we promised for it.
Under this plan a Johns-Manville roof ing user registers his roofing with us, at the time of application, by filling in a reg istration blank as shown on this page and forwarding it to our nearest branch. This blank is recorded and placed in the hands of our roofing department which arranges for a periodical inspection of your roofing by a Johns-Manville representative.
And this applies to every part of his roof ing because we believe it is our duty to see that Our materials in the flashings and gutters stand up as well as the surface of the roofing itself.
By this policy of roof registration we translate the formal terms of our guaran tee into active service value to you.
Be sure that when a Johns-Manville Roof is applied to your building a registra
This means that we keep careful track tion blank is filled out and forwarded to
of the roofing in service, and notify you of us so that you will obtain the benefits of
the results of our inspection and of any this service.
119
CRMC-003483
Johns-Manville Service to Railroads
Approval by the Underwriters
HE attitude of insurance authorities and maintained under the direction of the
Ttoward a building material is of spec- National Board of Fire Underwriters, the ial interest, both because of its effect official body representing all recognized
on insurance rates, and because it serves fire insurance companies of the country,
as a reliable index to the fire-resistant At these laboratories, roof coverings of
properties of the material m question. e
description are tested, examined
For this reason the results of tests made and classified according to their resistance
by Underwaters Laboratories, Inc., are of t0 fire. The tests made
these roof_
particular importance to the prospective in ar most severe and exhaustive in_
buyer of any building material.
cluding the radiant heat; burning brand
The Underwriters' Laboratories are lo- and flame exposure tests described and cated at Chicago, 111., and are financed by illustrated on this and the following pages.
FIG. 1--MAKING RADIANT HEAT TEST The temperature of the circular plate at the lowest point of the gas
furnace is approximately 1200 degrees Fahrenheit. See page 124 for details of test.
120
CRMC-003484
Johns-Manville Service to Railroads
FIG. 2--APPARATUS .USED IN MAKING STANDARD FIRE TESTS OF ROOF COVERINGS
The cylindrical gas'furnace is. mounted on trunnions so it can be turned to any . . angle: at7.which: the':. roofing is tested.. The air duct is of sheet ;nietal and has a
; v-. ; L -. discharge opening 7 by 2$4 feet.
FIG. 3--APPLYING SAMPLE ROOFING TO STANDARD DECKS FOR TESTS
Experienced men are employed to do this work. A pile of completed decks is shown at the left. The motor and fan for securing the wind velocities are shown
in the background.
121
CRMC-003485
Johns-Manville Service to Railroads
Burning Brand Test
SAMPLE SUBJECTED TO AIR CURRENTS OF 12 MILES PER HOUR
Exposed Sidei;
Unexposed Side. /
SAMPLE SUBJECTED TO AIR CURRENTS OF 40 MILES PER; HOUR
Exposed Side.
Unexposed Side.
Figure 4
Fig. 4--Photograph at top of page on left shows condition of Johns-Manville Asbestos Roofing after burning brand test; photograph on right shows under side of sheathing after same test. Wind velocity 12 miles per hour.
Photograph at bottom on left shows condition of Johns-Manville Asbestos Roofing after burning brand test with wind velocity of 40 miles per hour; photograph on right shows under side of sheathing after same test. See page 125 for details of test.
122
CRMC-003486
Johns-Manville Service to Railroads
Flame Exposure Test
SAMPLE SUBJECTED TO AIR CURRENTS OF 12 MILES PER HOUR
Exposed Side;..
Unexposed Side..
SAMPLE SUBJECTED TO AIR CURRENTS OF 40 MILES PER HOUR
Exposed Side.
Unexposed Side.
Figure 5
Fig. 5--Photograph at top on left shows condition of Johns-Manville Asbestos Roofing after flame exposure test, subjected to air currents of 12 miles per hour; photograph on right shows under side of sheathing after test.
Photograph at bottom, on left, shows
condition of Jobns-Manville Asbestos Roofing after flame exposure test, subjected to air currents of 40 miles per hour; photograph on right shows under side of sheathing after completion of same test, See page 126 for details of test.
123
CRMC-003487
Johns-Manville Service to Railroads
Radiant Heat Test
SAMPLE SUBJECTED TO AIR CURRENTS OF 12 MILES PER HOUR
The illustrations on the left show condition of sample subjected to air currents of
12 miles per hour.
Exposed Side.
Unexposed Side.
SAMPLE SUBJECTED TO AIR CURRENTS OF 40 MILES PER HOUR
The illustrations oh the; right show condition of ; sample subjected to air currents.; of
40 miles per hour.. '
Exposed Side.
Unexposed Side.
Figure 6
Fig. 6--The photographs above show the condition of the Johns-Manville As bestos Roofing and under side of sheathing after the radiant heat test was completed. In the radiant heat tests wind velocities of 12 miles per hour and 40 miles per hour are used to determine the effect upon the roofing material under examination. See page 125 for details of this test.
Seldom does a roofing on an average building encounter such conditions as it is called upon to withstand under the search ing eyes of the impartial official investi gators at the Underwriters' Laboratories; so that any roofing which meets these rigid laboratory requirements and is clas sified to take the base rate of insurance, may be safely put on any building with a
124
CRMC-003488
Johns-Manville Service to Railroads
Fig. 7--Flame Exposure Test Apparatus in Action. See pages 123 and 126 for details.
knowledge that it is fire-safe to the high-
est degree.
Johns-Manville Asbestos Roofings are
put through the tests described and
are given either Glass "AT'br. "B" rating,
according to the construction of the roof deck and the type of' roofing. Either Class "A" or Class "B" takes the base rate of insurance.
'v ;
Radiant Heat Test
To ; determirie ` how the ^ '.roofing:. will to simulate wiiid. A sample of_ roofing is
stand up when;:\subjecte<L;fi^
shown undergoing such>:d. test in Fig. 1,
heat from a nearby fire farinecf by\a breeze,- page 120. The resujts^M: this test are
a radiant heat test,is made-on the roofing: shown in Fig. 6, page l:24tr ;
while it is exposed,to varyihg air currents
:iV
Burning Brand Test
To determine the fire resistance of a roofing when burning brands fall upon it, as is liable to happen to adjacent buildings when fire breaks out while a strong wind is blowing, each roofing examined at the Underwriters* Laboratories is sub-
jected to the burning brand test. In performing this test the burning
brand is made up of 1" by 1" maple strips formed into a grid, the strips being approximately *4" apart and held together
by similar strips to which they are nailed, The brand is approximately one foot square and is ignited by placing it in a gas furnace. This furnace is heated by a grill of gas jets which form the bottom of the furnace chamber.
The brand is supported above the jets and is exposed to the heat of the furnace until it is all aglow and completely covered with coals. The glowing brand is then lifted from the furnace and placed in
125
CRMC-003489
Johns-Manville Service to Railroads
the proper position on the surface of the roofing sample. The brand is permitted to burn until entirely consumed or until the roof covering has failed by permitting the ignition of the deck boards on the un der side. One operator carefully notes the time of ignition and the spread of flames
on the surface of the covering, also the rate at which the brand is consumed. An other operator observes the condition of the sample on the under side.
Fig. 4, page 122, shows the condition of Johns-Manville Asbestos Roofing and the under side of sheathing after this test.
Flame Exposure Test
To observe the behavior of roofing un- fails and the deck boards are ignited. One
der the action of flame playing directly operator observes the time of ignition of
upon it as might occur on a building roof, the covering and the rate of spread of
a direct flame contact test is made.
flame over the surface while another oper-
The apparatus used in subjecting sam- ator observes the under side of the deck
pies of roof covering to direct flame con- and notes the time in which the deck
tact is illustrated in Fig. 7, page 125. This boards take fire. The effects of such a test
apparatus consists of a burner with an ori- on Johns-Manville Asbestos Roofing are
fic.e 36 inches long and y2. inch wide from evidenced in Fig. 5, page 123.
which a gas flame is emitted. The flame As a result of the extremely high fire
passes over the surface of the sample di- resistance afforded by Johns-Manville
rectly exposing an area about 36 inches: Asbestos Roofings under these tests they
wide by 36 inches high,-;have been given highest ratings---Class
- The'Sample is set in-place before the- "A" or "B," according to roof deck and
apparatus and the burner, is ignited. The type of construction and take base rates of
sample is thus exposed-until the covering insurance.
Dock Freight Sheds of Michigan Central Railroad, at Detroit, Mich., showing application of Johns-Manville Asbestos Roofing.
126
CRMC-003490
r
Johns'Manville Service to Railroads
J M*
~i-Jd'' t?
hii-USi
RAILWAY EXCHANGE BUILDING,
: ,ST. LOUIS, MO.,
Covered with Johns-Manville Asbestos Built - up Roofing. Mauran, Russell and Crowell, Architects, St. Louis.
! ?. -
Johns-Manville
Asbestos Roofings
in different forms;
for every type of
service:
Page
Built-up Asbestos Roofing 128
Shingles, Asbestos (Rigid
type) ........:.
167
Shingles, Asbestos, (slate , surfaced, flexible type) . 179
Ready-to-lay . Roofing, As bestos, smooth and slate surfaced ............................ . 141
Asbestos Protected Metal Roofing and Siding.... 159
Corrugated Roofing and Siding, Transite.............. 151
Ready-to-lay roofing, ragfelt, smooth and slate surfaced .............................. 183
127
CRMC-003491
Johns-Manville Service to Railroads
Round House of the Central Railroad of New Jersey, Communipaw, N. J., showing Johns-Manville Asbestos Built-up Roofing and Johns-
Manville Transite Asbestos Wood Smoke. Jacks.
Johns -Manville Standard Asbestos
Built-up Roofing
OR fiat or pitched decks up to 6" to Realizing that a durable roofing must
Fthe foot; Johns-Manville Standard be made of raw materials that are natiir- Asbestos Built-up Roofing can also ally durable, Johns-Manville uses Asbestos
be.laid on pitches exceeding 6" to the foot felts and natural asphalts--two minerals
where: suitable nailing is provided,
'intended by nature .for: permanent water
As a roofing cannot-be better than the . and weather protection.-
-
materials of which it is made; .it is of-first Therefore, Johns-Manville Standard
importance to know the nature and prop- Asbestos Built-up Roofing, composed of
erties of the raw materials used to produce these two minerals--is different and natur-
it. If such raw materials are inherently ally affords longer and more economical
perishable or inflammable it would natur- service than roofings made of perishable
ally follow that the finished roofing would materials,
have the same limitations.
Its Main Points of Difference and Superiority Are;
It Is More Durable
It will last indefinitely because it is made of rock. There is nothing in it to rot or dry out. Asbestos, of which it is made, is a mineral that is practically as old as life
on earth; a mineral that has resisted the destructive forces of nature for centuries and is immune to rot and weather,
128
CRMC-003492
Johns-Manville Service to Railroads
It is More Economical
because it does not require painting, coat ing or surfacing of any kind after its in stallation. The reason it does not require this form of maintenance is that the asbes tos felts retain their asphalt impregnation and do not dry out. As compared to rag felt roofings, which do require such expen
sive upkeep, the elimination of this item with Johns-Manville Standard Asbestos Built-up Roofing represents a considerable and increasing saving, particularly where the roof area is large and service condi tions severe enough to compel frequent maintenance of other roofings.
Its Asbestos Felts
are waterproofed and built up on the roof deck with refined natural asphalts, the conceded best of all roofing and waterproofing agents. No coal tar pitch is used in the manufacture or application of Johns-Manville Standard Asbestos Built-
up Roofing. Our asphalts are carefully chosen and blended for longest life. We own no oil wells; we have no asphalt de posits to exploit; we buy only those ma terials that satisfactorily meet our high standards.
Its Smooth Finished Surface
means quicker and better drainage; for this construction the surfacing is likely
quick and easy tracing of leaks due to be separated from the felt by the sun
to abuse or accident to the roofing and cor- and carried away, by water, snow and ice,
rection with the minimunf of time, labor leaving the perishable rag felts exposed to
and expense.
V^-the direct attack of sun and: weather.. As
Its ! smooth surface . is particularly- they are not intended for such exposure'
adapted to sawtooth, cdnstructipp. Where the surfacing must be quickly replaced or
"a siag ot:gravel' surfacedv noofihg;:-is. used the felts may crack ana disintegrate. ' `
It is Reinforced at the Vital Points
the -valleys and flashings, --^the; places bination of asbestos, special Sashing fabric where, practically -90% - of all roofings and Asbestile Gerpent,-applied according troubles occur;; The flashings 'are a: com- to Johns-Manville specifications. .
It is Light in Weight
weighing approximately 300 to 400 pounds less per square thaii gravel or slag surfaced roofings.
Due to the durability of the materials used and the effectiveness of these specifi-
cations Johns-Manville can afford to back up the performance of' its Asbestos Builtup Roofing, including the flashings, with Johns-Manville Responsibility,
It is Approved by Underwriters' Laboratories, Inc.
and given Class "A"or"B" rating, according to the roof construction. Either classification takes base rates of insurance.
And you get the benefit of the JohnsManville plan of roof registration by
which we see that you get proper service from our roofing. See page 119 for complete details of this plan of roof registration.
You obtain the advantage of the pro-
129
CRMC-003493
Johns-Manville Service to Railroads
gressive improvements which our engi neers develop from practical experience. They study each particular roof deck and plan its roofing to meet the requirements
of the structure and the service demanded. Some of the details of application as shown in this section will be of interest to architects and engineers.
Johns-Manville Insulated Roofing
Where conditions of condensation or objectionable room temperatures from ex terior conditions are encountered, JohnsManville Insulated Asbestos Built - up Roofing will effectively eliminate a great percentage, if not all, of the trouble.
Johns-Manville Insulated Roofing is a combination of our Standard Asbestos Built-up Roofing applied over an efficient, durable, insulating felt that reduces the heat and cold conductivity of the roof deck. This felt is known as Johns-Manville
Roofinsul. The drawings on page 137 show some details of application of Johns-Man ville Insulated Roofing. Our engineers will be glad to make a survey of your con ditions and give you full recommendations without obligation on your part.
Whether you have a mammoth indus trial building or a one story addition the same degree of satisfaction and service is assured and the same scrupulous attention given to the application of the job, as well as the advantages of registration. :
130
CRMC-003494
Johns-Manville Service to Railroads
Specifications--Johns-Manville Standard Asbestos
Built-up Roofing Over Wood Sheathing
Underwriters' Laboratories, Inc. Class "A"
On all wood roof decks as shown on plans apply JohnsManville Standard Asbestos Built-up Roofing as follows:
Materials
Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns - Manville Standard Asbestos Built - up Roofing Felt.
Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb.
Nails: To be 1/%" barbed nails and flat tin caps. Asphalt Cement: To be Johns-Manville As phalt Roofing Cement. Flashing material as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over wood sheathing as follows:
Application of Materials
1. Lay sheets of the 60 lb. felt directly over the
Start at low point of roof with a one-half width sheet
sheathing. Lap the joints 3" and seal them with asphalt of the 14 lb. felt, then a full width sheet of the same
cement. Nail these sheets along the lap with barbed felt laid flush with and entirely covering the one-half
nails-driven through flat - tin caps, - spaced 6"' apart.' width sheet. Then lay full width sheets, setting the
The 60 lb. felt shall be laid parallel to pitch of roof and turned up 2"'on all vertical surfaces, but not ce mented to vertical surfaces. ,
first so as to over-lap the one-half width starting sheet 2" and then exposing 15" of each succeeding sheet to the weather.
Mop the entire surface between plies with the asphalt
' Over the 60 lb. felt,'Edging strips composed of"the, cement, heated to flow freely, and roll the felts closely
Flashing Material shall be applied at eaves^ arid gable . behind the mop so that no missing of asphalt can pos
over-hang,, extending.. 4" on roof, cemented and nailed, sibly take place.
.and turned down over and .secured to fascia and pro
Nail the back,edge, of, each, sheet with the barbed
jected'.^" beyond .to. form a drip' edge. . V;
nails driven through flat- tin caps spaced 9" apart; the
>. 2.. Mop the entire surface of the .60 lb. felt with- .the : -. center line of hail heads to be approximately Yi" be
asphalt cement,, heated,,to flow 'freely, and while th.e low back edge of sheet.'.
; -'
cement is- hot, imbed,in it- sheets .ofv-the 14 lb. felt in
3. ` When the* ropfing is' othefwise complete, cover
two-ply construction, the 14 lb, felt.to be run'at right, the entire surface with a mopping of the asphalt ce
angles to the, 60- lb. felt, lapped 17'-.and turned.up 2" ment, to be applied hot, using approximately 25 lbs.
on all-vertical-suffaces. v,
to the square. (See detail on page 135.)
Flashings
Walls and all other elevations ^bove .roof sur- shall be composed of base flashings of Johns-
fa.ce shall be.-, carried vertically at least 12" to; . Manville Asbestos Flashing material, approxi-
provide for proper flashing. ' . A
. mately 10^"; wide, cemented and nailed to ver-
Roofing material shall ,be carried up on all tical surface. Such flashing shall be counter-
vertical surfaces 2". All flashings, except those flashed with Johns-Manville'Asbestile System,
around ventilators, stand-pipes, exhausts, etc.,
Preparation of Roof Surface
The jollouing to he inserted in Carpenter s specifications:
Sheathing boards shall be dry, well seasoned and of uniform thickness, laid closely--tongue and grooved sheathing preferred.
Roof surface shall be graded to drain all water freely into gutters and down-spouts. Ends of all sheathing boards shall rest on and be properly secured with at least two nails to joists or purlins. If edges of sheathing boards are curled up, they shall be drawn down and properly secured to joists or purlins, eliminating all standing nail heads and other projections. All loose knots and other flaws shall be removed, and all holes prop
erly filled or covered. All loose nails, chips and ether rubbish shall be removed and the deck made and maintained perfectly clean and free of all obstructions other than tools and appliances of roofer. All drainage connections shall be set to permit free flow of water. A 3" x 3" triangular wood strip shall be furnished and installed (wherever base flashings are to be used) in the angle formed by roof and vertical surface. All to be done by owner or contractor other than roofing contractor.
131
CRMC-003495
Johns-Manville Service to Railroads
gres?'
- Specifications--Johns-Manville Standard Asbestos Built-up Roofing Over Non-Combustible Roof Surfaces
Underwriters' Laboratories, Inc. Class "A"
On all non-combustible roof decks as shown on plans apply Johns-Manville Standard Asbestos Built-up Roofing as follows:
Materials
Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns-Manville Standard Asbestos Built-up Roofing Felt.
Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb.
Asphalt Concrete Primer: To be Johns-Man ville Asphalt Concrete Primer.
Asphalt Cement: To be Johns-Manville As phalt Roofing Cement.
Flashing materials as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over DRY con Crete or gypsum roof deck as follows:
Application of Materials
1. Coat the concrete or gypsum with the cold primer, lb. felt, lapped 17" and turned up 2" on all vertical
using approximately 1 gallon over concrete and 1 to 2 surfaces.
gallons over gypsum per 100 square feet of roof sur
Start at low point of roof with a one-half width sheet
face to provide a proper bond between roof deck and of the .14 ,1b. felt; then a. full, width sheet of. the. same
asphalt. Allow the. primer to dry.
.felt laid flush with and entirely covering the one-half
2. Mop the entire Surface thus primed with the .width sheet. Then, lay full width sheets, setting the
asphalt cement, heated to flow freely and while the first so as to over-lap the one-half width starting
cement is hot; imbed in it sheets of the 60 lb. felt. sheet 2", and then exposing 15" of each succeeding
Lap'the'joints 3" and seal them with.the hot asphalt, .sheet to the weather. .. ;
cement. The 60 lb. felt shall be laid parallel to pitch; of
Mop the entire surface between plies with the asphalt
roof ahd.'.-tu'rh'e'd up 2" on all vertical surfaces, but hot cement, heated to. flow freely, and roll the felts closely
cemented to;vertical -surfaces.
behind .the mop . so that no missing of asphalt .can pos
Over the 60 ,1b. felt/Edging strips composed of the sibly take-place.
'
.
Flashing vIdat'erial' shall.'.be applied'. at . eaves and gable over-hang-extending 4" on fOof, cemented and turned down over and secured to fascia and. projected'^" be
; !:
4. On gypsum- arid other, types of roof decks permit of nailing, the:`laps of the 60 -lb. felt and the edges of the 14 lb. felts shall be securely nailed to
that back roof
slab with cut nails driven through flat tin caps in ad
yond'to form a drip' edge, .- .
dition to mopping.
'-
... 3. Mop the entire surface of the 6.0. :1b. felt with the
5. When the roofing is otherwise complete, cover
hot .asphalt cement, and while the cement is hot,-imbed the entire surface with a mopping of the asphalt ce
in it -.sheets, of the 14; lb. felt, in-,tw.o-ply construc ment, to be applied, hot', using'approximately 25 lbs. to
tion, the: 14 lb. felt, to be .run. at right , angles to the 60 , the square, (See detail on page 135.)
Flashings
Walls and other elevations above roof surface shall ;be carried vertically at least .12" to provide for proper flashings.
Roofing.material shall be carried up on vertical surfaces 2". All.flashings, except those around ventilators, stand-pipes, exhausts, etc., shall be composed of base flashings of Johns-Manville Asbestos Flashing material approximately 10*4"
wide. Such flashings shall be counter-flashed with Johns-Manville Asbestile System,
NOTE: On concrete surfaces maximum pitch upon which this roofing may be applied .without nailing is 3" to the foot except on short runs, as in sawtooth construction. If wood nailing strips are inserted in concrete, the pitch may be increased.
Preparation of Roof Surface
The folioicing to be inserted in Mason's specifications:
Roof surface shall be graded properly to drain all water freely into gutters and down-spouts. Roof surface shall be finished smooth and hard, containing no depressions or projections and must be thoroughly set, air-dry and free from frost. All rubbish shall be removed and the deck made and maintained perfectly free of all ob
structions other than tools and appliances of the roofer. All drainage connections shall be set to permit free flow of water. The angle formed by roof and vertical surface (wherever base flash ings are to be used) shall be rounded into proper cove. All to be done by owner or contractor other than roofing contractor.
132
CRMC-003496
Johns-Manville Service to Railroads
Specifications--Johns-Manville Asbestos Built-up Roofing Over Wood Sheathing
Underwriters' Laboratories, Inc. Class "B"
On all wood decks as shown on plans apply JohnsManville Asbestos Built-up Roofing as follows:
Materials
Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns-Manville Standard Asbestos Built-up Roofing Felt.
Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb.
Nails: To be 7/q" barbed nails and flat tin caps.
Asphalt Cement: To be Johns-Manville As phalt Roofing Cement.
Flashing material as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material.
Such materials shall be applied over wood sheathing as follows:
Application of Materials
1. Lay sheets of the 60 lb. felt directly over the sheathing. Lap the joints 3" and seal them with asphalt cement. Nail these sheets along the lap with barbed nails driven through fiat tin caps, spaced 6'' apart. The 60 lb. felt shall be laid parallel-to pitch of roof, and turned up 2" on all vertical surfaces, but not ce mented to vertical surfaces;
Over the 60 lb. felt, Edging strip.s- composed of the Flashing Material shall be applied at eaves and gable ; oyer-hang, extending 4" on roof, cemented and nailed,. ' and turned, down over and secured''to fascia and. pro
jected
to form a .drip edge.-
2. Mop- the. entire, surface of the 60 lb. felt with the ;.asphalt cement, heated, to flow freely, and while the
cement is hot, imbed imit sheets :of the 14 lb, felt in . single-ply construction; the. 14 -lb.: felt -*0 be run at. right
angles to the 60 lbi felt; lapped -3" and; turned up-2"-
on all vertical'surfaces.
Start at low point of roof with a one-half width sheet of the 14 lb. felt, then a full width sheet of the same felt laid flush with and entirely covering the one-half width sheet. Then lay full width sheets, over-lapping the preceding ones 3",, with. 29" exposed to the weather.
; Mop the entire surface between plies with the asphalt cement, heated to flow freely, and roll the felts closely behind the mop so that no missing of asphalt can pos-. ,'sibly take place.,
Nail the backedge of each sheet with the-barbed nails driven through -fiat tin. caps spaced 9" apart; the, center line of nafi heads.'to be approximately 54" be low back edge of sheet.
3. When the roofing 'is . otherwise complete, cover the entire surface /with, a mopping of the asphalt cement, to be applied hot,., using approximately 25 lbs. to the square. (See detail on page 136.)
Flashings
,
;Walls and all other elevations above roof sur face. shall' be. carried vertically' at least 12" to provide for proper, flashing.
Roofing material shall / be: carried up on- all vertical surfaces 2".All flashings, except those
around ventilators, stand-pipes; exhausts, etc.; shall be composed: of' base flashings of JohnsManville Asbestos Flashing material, approxi mately 10^2" wide, cemented and. nailed to ver tical surface. Such flashing shall be counterflashed with Johns-Manville Asbestile System.
Preparation of Roof Surface
The following to be inserted in Carpenter's specifications:
Sheathing boards shall be dry, well seasoned and of uniform thickness, laid closely--tongue and grooved sheathing preferred.
Roof surface shall be graded to drain all water freely into gutters and down-spouts. Ends of all sheathing boards shall rest on and be properly secured with at least two nails to joists or purlins. If edges of sheathing boards are curled up, they shall be drawn down and properly secured to joists or purlins, eliminating all standing nail heads and other projections. All loose knots and
other flaws shall be removed, and all holes prop erly filled or covered. All loose nails, chips and other rubbish shall be removed and the deck made and maintained perfectly clean and free of all obstructions other than tools and appliances of roofer. All drainage connections shall be set to permit free flow of water. A 3" x 3" triangular wood strip shall be furnished and installed (wherever base flashings are to be used) in the angle formed by roof and vertical surface. All to be done by owner or contractor other than roofing contractor.
133
CRMC-003497
Johns-Manville Service to Railroads
Specifications--Johns-Manville Asbestos Built-up Roofing
Over Non-Combustible Roof Surfaces
Underwriters' Laboratories, Inc. Class "B"
On all non-combustible roof decks as shown on plans apply Johns-Manville Asbestos Built-up Roofing as follows:
Materials
Felts: A heavy base sheet of asphalt impreg nated asbestos roofing felt 32" wide, weighing approximately 60 lbs. per 108 square feet: to be Johns-Manville Standard Asbestos Built-up Roofing Felt.
Single ply sheets of asphalt impregnated asbes tos roofing felt 32" wide, weighing approximately 14 lbs. per 108 square feet: to be Johns-Manville Asbestos Roofing Felt 14 lb.
Asphalt Concrete Primer: To be Johns-Man ville Asphalt Concrete Primer.
Asphalt Cement: To be Johns-Manville As phalt Roofing Cement.
Flashing materials as specified hereinafter. Edging: To be Johns-Manville Asbestos Flash ing Material. Such materials shall be applied over DRY con crete or gypsum roof deck as follows:
Application of Materials
1. Coat the concrete or gypsum with the cold primer, tion, the 14 lb. felt to be run at right angles to the 60
using approximately 1 gallon over concrete and 1 to 2 lb. felt, lapped 3" and turned up 2" on all vertical
gallons over gypsum per 100 square feet of roof sur-. . surfaces. .. .
face to'provide a proper bond between roof deck and
Start at low. point of roof with a one-half width sheet
asphalt, Allow the primer to dry.
of the 14 lb. felt; then a. full width sheet of the same
. felt laid flush with and entirely covering the one-half
2.-..'-Mop : the . entire.;, surface . thus primed with '-the' asphalt cement, heated' to .flow, freely .and while the cement..is-.hot,, .imbed . in,.it .sheets, oi: the 60 lb. felt,,
width sheet. Then lay full width sheets, overlapping the preceding ones 3", with 29" exposed to the weather.
-Lap the .joints. 3" ..and .seal them with .the hot asphalt . Mop the entire surface betweemplies with the> asphalt
cement.,. The 60.1b. felt shall beriaid parallel to pitch;of . cement, heated to flow freely, and roll the felts closely
roof, an^: turned up. 2". p,n all vertical surfaces, but not behind the mop so that no missing of asphalt - can pos
.cemented to vertical surfaces. ./
v sibly takeplace.;
v .Over:.the 60 Ib^ felt,. Edging strips composed of theFlashing, Material shall be applied at. eaves and gable, over-hang^; extending;:^" ion roof, cemented, and .turned;
down'over and secured to fascia and projected J4" be
.
4. On gypsum and other types of roof decks that `permit o. nailing, the laps -of the 60 lb., felt and the back . edges of the 14 ,1b. .felts',shall be securely nailed to roof slab with cut nails , driven through flat tin caps in ad dition to. mopping.
yond to form a drip' edge..-
; 5. When the roofing is otherwise complete, cover
, ; 3/ Mop the entire- surface of'the 60 lb. felt with the the entire surface with a, .mopping, of the asphalt ce-
hot; asphalt, .cement, ahd.while the .cement .is hot, imbed njent, to be applied hot, using, approximately '25 lbs. .to
in it sheets of the 14 lb- felt, 'in single^-ply construc the square.' (See detail' on page 136.)
Flashings
Walls and other elevations above roof surface shall be carried vertically'at least 12" to provide for proper flashings.
Roofing material shall be carried up on vertical surfaces 2". All flashings, except those around ventilators, stand-pipes, exhausts, etc., shall be composed of base flashings of Johns-Manville Asbestos Flashing material approximately 10*4"
wide. Such flashings' shall ..be counter-flashed with Johns-Manville Asbestile. System,
NOTE: On concrete surfaces maximum pitch upon which this roofing may be applied without nailing is 3" to the foot except on short runs, as in sawtooth construction. If wood nailing strips are inserted in concrete, the pitch may be increased.
Preparation of Roof Surface
The jolloiving to he inserted in Mason's specifications:
Roof surface shall be graded properly to drain all water freely into gutters and down-spouts. Roof surface shall be finished smooth and hard, containing no depressions or projections and must be thoroughly set, air-dry and free from frost. All rubbish shall be removed and the deck made and maintained perfectly free of all ob
structions other than tools and appliances of the roofer. All drainage connections shall be set to permit free flow of water. The angle formed by roof and vertical surface (wherever base flash ings are to be used) shall be rounded into proper cove. All to be done by owner or contractor other than roofing contractor
134
CRMC-003498
Johns"Manville Service to Railroads
ddpi'np fa v. carried out an roe/* as sfioiun and turned doian airier /asera.
Details' -of ^application. of Johns-Mahville Standard Asbestos. Built-up Roofing-- Underwriters' Laboratories Class "A" over wood sheathing: Drawing.. R-94-S
~'dpinp fa Pe carried out an reef as sfratan end fumed dawn overfascia
Details of application of Johns-Manville Standard Asbestos Built-up Roofing--Under writers' Laboratories Class "A" over non-combustible roof surfaces: Drawing R-94-C
135
CRMC-003499
Johns-Manville Service to Railroads
Details- of application of r Johns-Manville Asbestos Built-up RoofingUnderwriters'.Laboratories Class '`B" over wood sheathing: Drawing &-38
Details of application of Johns-Manville Asbestos Built-up Roofing--Underwriters' Laboratories Class "B" over non-combustible roof surfaces: Drawing R-39
136
CRMC-003500
Johns-Manville Service to Railroads
Details'of application of Johns-Manville Roofinsul.(Va"- or XA" thick) in connection with JohnsManville Standard Asbestos Built-up Roofing---Path Method--Sheathing--Drawing; R-42
Details of application of Johns-Manville Roofinsul
or z/2" thick) in connection with Johns-
Manville Standard Asbestos Built-up Roofing--Path Method--Concrete--Drawing R-43
137
CRMC-003501
Johns-Manville Service to Railroads
Coping to be set after- flashing is on place flashing to be ca.7~r-z.ed to within ? "of outside face of coaZZ
ftt**lU-
It ts advisable to have angle farm ed by watt and roofslab rounded
inJ&. proper cove
+iTt'C-'-*o-'n-c/. y. ..1v'" sa^osnjy\
Details of Johns-Manville Asbestile System of Flashing--Cap flashing carried up wall. and-a'crossVtOp under coping'to within 2" of outside face--Drawing F-l8.
HOTS-rAl! - bricJz CofcOnereTe) surfaces to
. be .printed with '.Jbhns-Ptanz/iZle Gsncrets
Primer before mopping with fspliaZt
RoafingOtment.
--
'plies' of Jbh.ns~`Ptani7zZle jSsbestos
Roofing Felt, /4 lit., carr.ief over brzch'Zey and mopped solid '. Required length o ~^\
project.and. be left loose ; until base is
iTtsZdlled.
-Flashing to- exten
f
To zoithzTi Z"
' of outer' face
oftuall.
Details of Johns-Manville Flashing--Cap flashing carried through wall over brick key to within 2" of outside face--Drawing F-24. 138
CRMC-003502
Johns-Manville Service to Railroads
^Details of Johns-Manville Asbestile System of Flashing. ; (Concrete wall and concrete roof deck):--Drawing F-27.
Details of Johns-Manville Built-up Gutter in wood sawtooth construction--Drawing G-20 139
CRMC-003503
Johns-Manville Service to Railroads
140
CRMC-003504
Johns-MaTiville Service to Railroads
The durability, freedom from maintenance and fire resistance of Johns-Mariville Asbestos Roofings assure the best fire and weather protection, for railroad buildings at the least cost.
Johns -Manville Asbestos Ready-to -Lay Roofings
OHNS-MANVIU.K Asbestos Ready-
f to-lay Roofings give years of positive protection- against firfe^and leather/ Q
by, special machinery into strong compact felts, which in turn ard thoroughly impreg
nated with natural/ asphalts of known
a comparative basis--as to first cost plusvalue for durability.: !
repair cost -- Johns. - Manville - Asbestos .' Ready-today Roofings effect a ' saving
which represents a splendid return on the investment.. That's why they are called the "cheapest-per-year". roofings.
Their low upkeep is due to the unchang ing properties of the raw material, asbes tos, plus proper design and manufacture.
These properties are not subject to var
.
And this asphalt impregnation does not dry out. It is held intact and protected in the body of the felt--actually sealed there because, unlike animal or vegetable fibres, asbestos fibres are non-tubular. They are immune to the capillary attraction set up by sun and weather, which draws off the asphaltic oils of roofings composed of tu bular animal or vegetable fibres.
iation, nor are they dependent upon any
coating or reinforcement which requires Made in different styles and weights to
periodical renewal. It is because of what's meet different types of buildings and vary
IN them--not ON them--that Johns- ing service conditions. Suitable for appli
Manville Asbestos Ready-to-lay Roofings cation on engine houses, sheds, stations,
give years of fire and weather protection tool houses, warehouses, shops, elevators
to the buildings they cover.
or on any type of building where a ready-
Selected asbestos fibres are fabricated to-lay roofing is desired.
Hi
CRMC-003505
Johns-Manville Service to Railroads
Flexstone Brand Asbestos Ready Roofings
Smooth Surfaced
Slate Surfaced
Double Coated
Flexstone slate surfaced roofing com
bines the attractiveness of a colored sur
MADE of heavy, tough felt of asbes tos fibres thoroughly impregnated
face with the fire protection of asbestos.
with natural asphalt and then Where a roofing must be ornamental as
heavily coated on both sides with aspwhaelltl. as durable this type will meet every
. Packed in one-square rolls which in requirement.
clude completing materials and instruc
It is made of the same asbestos fibres as
tions for application. Shipping weight ap Flexstone Smooth Surfaced Roofing. The
proximately 55 lbs. per square.
crushed slate is imbedded in the asphalt
Heavy
coating while it is hot. The asphalt used is carefully chosen and blended and retains
A rugged asbestos roofing of
its durability under all weather
special strength.
conditions and affords a posi
Made of three plies of asbestos felti Packed in one-square rolls which include completing mate rials and instructions for appli cation, Shipping weight, ap proximately 60 lbs. per. square.
. - Also made in sheets 32" x 80" which are shipped six sheets to a-: spuare.and. five squares ,to.the: prate. Shipping weight -approxi mately 72 lbs. per square, crated,: . including' completing materials and instructions fox application.
JohnsManville
fiEXSTONi
asbestos
roofing
tive, firm, constant grip, on the particles of the surfacing.
Furnished with a surfacing of . crushed red, green or blue-black slate. The choice of surface color is merely a matter of per sonal taste or of harmonizing the roof with the side-wall color ing.
v Packed in y One-square rolls which : include : completing ma-. Aerials and instructions for. ap plication:, Shipping weight, ap proximately 80 lbs. per square.
Extra Heavy ;
. The heaviest type of Flexstone. Made of four plies of as bestos felt. Particularly adapt ed for service where acid or gas conditions exist.
Furnished only in sheets 32" x 80". Packed in crates, 6 sheets to.the square; 4 squares to the crate. Shipping weight approxi mately 95 lbs. per square, crated, including completing materials and instructions for application.
Industry has found in Johns-Manville Flexstone and other Asbes tos Roofings the cheap est per year roofings.
Underwriters' Approval
Johns-Manville Asbestos Ready-to-lay Roofings, Flex stone and White Top Brands, are approved by Underwriters' Laboratories, Inc., and take base rates of insurance.
And they are backed not only by a definite guarantee, but by the broader and more satisfac tory terms of the Johns-Man ville plan of Roof Registration, described on page 119.
142
CRMC-003506
JohnsAianville Service to Railroads
White Top (Brooks Brand) Asbestos Ready Roofing
OHNS - MANVILLE White Top white side is exposed the pitch of the roof
J (Brooks Brand) Asbestos Roofing is must be at least 3" to the foot. particularly adapted for saw-tooth con Made in two weights--heavy and extra struction and buildings where the whiteheavy. Heavy is shipped in rolls of 1 or
surface of the roofing has the advantage2 squares which include necessary com
of reflecting a maximum of sunlight into pleting materials and full instructions for
the interior of the building; also widely application. Approximate shipping weight
used on buildings where a clean, neat, 62 lbs. per square. Extra Heavy is fur
white roof surface is desired.
nished only in sheets 32" wide by 80" long,
Made of two or three plies of asphalt 6 sheets to the square; 4 squares to the
impregnated asbestos felt and one ply of crate. Approximate shipping weight 90
unimpregnated (white), asbestos felt, ce lbs. per square, crated, including complet
mented together with asphalt. It can be ing materials and instructions for applica
laid either side to the weather but where tion.
Safeguard the Application with Pyramid Kaps
(Fig. 1)
(Fjg.. 2)
-Under the old system (Fig. 1) nails driven into cracks work loose and eventually come. out,= leaving, holes through both layers of roofing, causing leaks. X Under the.Pyramid Kap.System (Fig. 2) the continuous pressure of the strip and, the
adjoining, kaps eliminate all trouble from this source.
:. -We recommend the application ofall - nailing points and to tear away at the laps
pur/ Ready-today Roofing's ..with. Pyramid under the strains from expansion, con
Kaps. . These are .patented fasteners that traction and wind pressure;
exert,a positive, even and continuous pres-*, sure along all'laps, and provide a more sat-: isfactory weathertight and watertight,job than -is possible with nails and cement.
Pyramid Kaps are designed for quick and easy application and applied, end to end, along the entire length of all horizon tal and vertical laps, provide a continuous, evenly distributed pressure at all points where the roofing felts are joined.
Experience clearly shows that nails driven through tin caps or large headed nails and cement are woefully inefficient. Their principal fault is that they offer but a relatively small and intermittent binding
90% of all leaks experiericed.-With readyto-lay roofing can be traced to faulty laps which are so difficult , to avoid when only nails and cement are used in the applica tion. These troubles are positively avoided by the use of Pyramid Kaps, which in ad^ dition to their great efficiency enhance the general appearance of the finished job, giving a neat, standing-seam effect.
Pyramid Kaps are furnished only when ordered, and at slight additional cost, but this is negligible when their advantages and the satisfaction they afford the user are considered.
pressure over the laps (when spaced the
Be sure to specify Pyramid Kaps in
usual 2" apart) and permit the roofing your orders for Asbestos Ready-to-lay
fabric to pucker and buckle between the Roofing.
143
CRMC-003507
Johns-Manville Service to Railroads
Standard Specifications for the Application of Johns-Manville Asbestos Ready-to-Lay Roofings
OR Asbestos Ready-to-lay Roofings
Fapplied over wood sheathing, moni tor type roofs, slow burning mill con
tra Heavy); Johns-Manville White Top (Heavy and Extra Heavy) and Flexstone Asbestos Slate Surfaced Roofing.
struction with saw-tooth roof, steep surOn White Top Asbestos Roofing and
faces, etc.
Flexstone Asbestos Slate Surfaced Roof
Note: The following specifications ap ing there is a black selvaged edge on one
ply to Johns-Manville Flexstone Asbestos side to permit proper joining at horizontal
Roofing (Double Coated, Heavy and Ex laps.
Materials
Asbestos roofing, 32" wide, ready for applica tion, to be Johns-Manville Asbestos Ready-tolay Roofing..............................................................Brand.
Cement for laps of roofing to be Johns-Man ville Lap Cement.
Roofing Fasteners to be Zinc ^Pyramid Kaps and special galvanized round head Pyramid Kap
nails; or
large head, galvanized roofing nails.
Flashing materials as specified hereinafter.
Gutters and valleys to be lined with JohnsManville Standard Asbestos Built-Up Gutter and Valley Lining.
Such materials shall be applied over wood sheathing as follows:
Application of Materials
\ .1. When in rolls cut the roofing materials into
With the Flexstone Double Coated Roofing lap
sheets approximately 13' 6" in length. When in the end joints 4", applying a coating of lap ce
sheets apply as received. Commence at eaves or ment in the joint.'
: gutters; and :apply' Such sheets parallel with them,
4. Secure all horizontal lapped joints: with
.flush with \edge and over edging, strip of special Pyramid Kaps butted end to end approximately
: -.flashing material, . which shall; have , been prev.- l/z" from edge of sheet or with large head gal
. iously applied.
:; :
vanized roofing nails on about 2" centers y"
h . 2. Lap horizontal joints 25, and apply an -in ..'.from-- edge of,sheet. . Secure .all vertical butted,
termediate layer of Johns-M:anville Lap Cement. joints-in a similar-manner applying-one row. of
3. Lay sheets so that vertical'joints will break fasteners.on each-side of vertical joint about yr.
joints with preceding courses of sheets as in brickwork. Butt the ends of the sheets at veftical joints closely together without lapping. Lay,-
with blabk side up (in all cases), the 6" wide strips of asbestos felt (furnished with all JohnsManville Asbestos . Ready-to-lay Roofing except Flexstone Double Coated) underneath each vertical joint, extending it 3" on each side of joint for entire width of roofing sheet. Be sure that lower end of butt lap is led out on top of sheet below. Cover each strip of felt furnished for a butt end joint with lap cement, and imbed the
back from same."
A"
With the Flexstone Double- Coated Roofing
secure all vertical lapped joints with the large
head nails spaced 1" apart,, staggered, or with the
Pyramid Kaps butted end to end.
5. Extend top sheets on each side of ridge
approximately 2" over ridge; lapping one sheet
over the other and nailing on 9" centers.
6. Apply a capping or finishing strip cut from
roofing material, approximately 10 y2" wide,
lengthwise of ridge; extend it equally on each
side of ridge and thoroughly secure its lower
edges with large head galvanized nails or Pyra
butted ends of roofing sheets into this cement.
mid Kaps.
Flashings
Walls and all other elevations above roof surface shall be carried vertically at least 12" to provide for proper flashings. If such flashings are to
be constructed in accordance with Johns-Manville Asbestile System, such walls and other elevations need not extend more than 8" to 10"
144
CRMC-003508
Johns-Manville Service to Railroads
above roof surface, unless otherwise demanded by local building authorities.
Roofing material shall be carried up on vertical surface approximately 2". All flashings, except those around ventilators, standpipes, exhausts,
etc., shall be composed of base flashings, of special Asbestos Flashing Material, approxi mately 1054" wide, cemented and nailed to ver tical surface. Such flashings shall be counterflashed with Johns-Manville Asbestile System.
Preparation of Roof Surface
(To be inserted in Carpenter's Specification)
Roof surface shall be graded to drain all water freely into gutters and downspouts.
Sheathing boards shall be dry, well seasoned and of uniform thickness, laid closely--tongueand-grooved sheathing preferred. Ends of all sheathing boards shall rest on and be properly secured with at least two nails to joists or pur lins. If edges of sheathing boards are curled up, they shall be drawn down and properly secured to joists or purlins, eliminating all standing nail heads and other projections. All loose knots and
other flaws shall be removed, and all holes prop erly filled or covered. All loose nails, chips and other rubbish shall be removed and the deck made and maintained perfectly clean and free of all obstructions other than tools and appliances of roofer. All drainage connections shall be set to permit free flow of water. A 3" x 3" triangu lar wood strip shall be furnished and installed (wherever base flashing is to be used) in the angle formed by the roof and vertical surface. All to be done by owner or contractor other than roofer.
Details of Application of Johns-Manville Asbestos Ready-to-lay Roofing. Drawing R-25.
145
CRMC-003509
Johns-Manville Service to Railroads
Washington Power and Reduction Co., Republic, Wash., showing application of Asbestoside with batten strips
placed over vertical joints.
Johns -Manville Asbestoside
OHNS-MANVILLE Asbestoside is an. Can be applied perpendicularly or horh
asbestos sheet. Wall1 siding (without . zontally. When applied, perpendicularly
metal reinforcement) for . application , the three ply roll stock should be used and
directly. oyCr sheathing on section houses; "wooden batten strips should be applied
stations, grain elevators, repair shops, and .over all joints, thus giving an attractive
: other, byildingsi' t^here protection against half-timber effect.':
fire, water, gases., chemical- fumes and all Completing materials consist of large
weather conditions is desired. ,
.head, thin shank, galvanized nails,-or
This, material, is composed of two or Johns-Manville Pyramid Kaps, as ordered.
three plies of asphalt impregnated asbes Star Brand (3-ply) is furnished in rolls
tos felt and one ply of: white or unimpreg of one square of 108 square feet or two
nated asbestos felt, all. cemented, together squares of 216 square feet, weighing ap
at the factory with asphalt. The unim proximately 64 lbs. per square; also in
pregnated sheet of asbestos felt produces sheets 16 x 50" weighing approximately
a white surface on one side. The material 70 lbs. per square, crated, without com
can be applied either side to the weather. pleting materials. Shipped in crates con
When the white side is exposed it pro taining 1 to 5 squares.
vides a clean, attractive surface that im Shield Brand (4-ply) is furnished in 16
proves the appearance of the building. As x 50" sheets only, weighing approximately
Asbestoside is a non-conductor of heat and 90 lbs. per square, crated, without complet
cold, it keeps buildings cooler in summer ing materials. Shipped in crates contain
and warmer in winter.
ing 1 to 5 squares.
146
CRMC-003510
Johns -Manville Service to Railroads
Standard Specifications for the Application of Johns-Manville Asbestoside (Exterior Wall Siding)
Applied Horizontally
Material to be applied over siding of building that sheets will butt against casing, covering the
as specified shall be:
3" extension of strip previously applied under
Asbestos Sheet siding ready for application in sheets 16" x 50"; to be Johns-Manville Asbesto side, Star or Shield Brand.
Fasteners to be either Johns-Manville large headed galvanized roofing nails or Pyramid Kaps and special nails, as specified.
Such material shall be applied over wood sheathing as follows:
If corner boards are to be used first apply a strip of Asbestoside of sufficient width to cover corner of building and extend 3" from under cor ner boards after they have been applied. The joints of these strips to be butted.
casing. Siding sheets shall be applied, white side to the weather longitudinally and parallel with the cornice and eaves. Perpendicular or cross seams shall be lapped 3". Horizontal or long seams shall be lapped 2".
Start first course at top with a full sheet, tuck ing the upper edge of same underneath the finish or frieze board.
Start the second course with a half sheet so that succeeding joints will break in the center of the sheet above.
Start the third course with a full sheet, the fourth course with a half sheet and so on in ro tation to break joints.
Top of door or window openings shall have a
To insure the proper alignment and the even
strip of Asbestoside approximately 10" wide ap application of Asbestoside, chalk lines should be
plied, so that it will rest on and extend over the snapped across the building.
face of the casing..
\
All seams shall be properly secured with large
Sides and bottom of door and window openings head roofing nails or oval head nails and Pyramid
shalbbe faced with a strip of Asbestoside of suffi Kaps. If large head nails are used they shall be
cient, width, to extend 3" beyond edge of casing. spaced on 2" centers $4V'"back from the edge of
The joints of-such strips shall be butted.
sheet. If oval head nails and Pyramid Kaps are
Corner boards and dobir and Window casings : used Kaps shall be butted end to end and placed
may' now be installed.' If-corner boards are not 34" back from edge of sheet.
to be used apply Siding so. that sheets will extend : If corner boards are not used apply, over cor-
flush with corners' :f. the- building.; If corner : ner of building arid Asbestoside previously ap
.boards; are.used: apply. Siding so that sheets will ; plied, 8" wide strips of Asbestoside bent at right
butt against corner.- boards,-, covering, the 3" ex `.angles so that they; will lap 4" oh the Asbestoside
tension of thel strip previously installed, under- . . on each side*. These strips to be fastened along
neath corner boards.
'> both edges with large head nails or oval, head
At door and window openings apply Siding so nails and Pyramid Kaps, \
Applied Perpendicularly
Where it is desired to apply Asbestoside perpendicularly: material in roll form 32" wide to be used. Sheets are to be cut from the roll not more than 10 ft. long.
The details of application, strips, lapping, fastening, etc., are the same as when the material
is applied horizontally. If desired, unplaned wooden battens, 3" :to 6" wide, may be applied over the laps of the finished job, thus- giving the building a half timber effect. These strips may be stained or painted as desired,
Preparation of Surface
(To be inserted in Carpenter's Specification)
Sheathing boards shall be dry, well seasoned and of uniform thickness laid closely, tongue and grooved sheathing preferred. Ends of all sheath ing boards shall rest on and be properly secured with at least two nails to joists or studs. If edges of sheathing boards are curled up they shall be
drawn down and properly secured to joists or studs eliminating all standing nail heads and other projections. All loose knots and other flaws shall be removed and all holes properly filled or covered. All to be done by owner or other con tractors.
147
CRMC-003511
CbjAC-003512
Johns-Manville Service to Railroads
/"T^O withstand successfully the excep- and acid fumes and second, because it. is
I tionally - severe conditions encoun- specially designed ior the purpose.
tered on railroad; locomotives, ,a roof ing material for .such purposes must not' .only resist the direct; and continuous at
,
It is made of asphdlt impregnated tos felts with a special reinforcing web of asphalt saturated fabric of
asbescentre great
tack of smoke, soot, steam' and sulphuro-us tensile strength. It is fire-safe and never
acid fumes, but it must be positively, fire- needs paint or similar maintenance.
safe because of the constant exposure to
sparks and hot cinders.
Johns-Manville Cab Roofing has been
' It must have the maximum of tensile' an accepted standard of locomotive build
strength to take care of the vibration and ers and designers and railroad mainten
movement of the cab frame. It must be ance engineers for many years because of
extremely compact and dense to resist the its durability and economy.
effects of driving rain, snow and sleet as
well as the surface friction and terrific wind pressure created when the locomo tive is at high speed.
Johns-Manville Cab Roofing is particu larly satisfactory, durable and economi cal; first, because it is immune to smoke
Specifications for Application
Remove all loose nails, chips, or other rubbish, leaving the surface perfectly clean and smooth. See that all boards are resting on purlins so that they cannot spring and that they are fastened securely with at least two nails at each purlin.
149
CRMC-003513
i Johns-Manville Service to Railroads
Roofing is furnished 32" wide and should be cut to suit width of cab, and laid with a 254" lap, thoroughly cemented with Johns-Manville Lap
Cement and nailed with large head galvanized
iron nails spaced not over 1 y2" apart. Roofing
to be laid crosswise of cab.
Johns-Manville Asbestos Barge Roofing
ROOFING material for barges must
A not only withstand particularly se vere weather conditions but it must possess exceptional tensile strength. The movement of a barge in rough water and straining due to the pull of tow lines are all transmitted to the super structure. Ordinary roofing used for building purposes would be impractical for use on barges. It cracks under these strains and requires constant patching and painting to retain its waterproof qualities.
Johns-Manville Barge Roofing is not subject to these limitations because it is an asbestos roofing and is specially de signed for marine service. It is made of asphalt impregnated asbestos felts with a
special reinforcing center web of fabric of great tensile strength.
It does not rot or dry out and it does not require painting or surfacing of any kind. Being mineral it is unaffected by the ac tion of salt air. It is the ideal material for the roofing of barges and similar craft.
Made in sheets 32" x 80"; packed 4 squares to the crate. Shipping weight, approximately 90 lbs. per square includ ing completing materials.
Johns-Manville Asbestos Barge Roof ing has been used almost exclusively for many years in roofing barges for railroads and private companies operating in the waters around New York.
Specifications for Application
Remove all loose nails, chips or other rub- iron nails spaced not over 2" apart. End laps to be
bish, leaving surface,-perfectly, clean. See that all butt lap construction. Where desired to protect
ends of boards are.resting-on and securely nailed, nail heads against exposure it is recommended
to supports so that they cannot spring.
. that all joints and nails be covered with a 4"
.-A'. wide strip of impregnated 14 lb. Asbestos Felt,
Roofing is furnished 32" Wide and should .he . laid in. and mopped on top with hot Johns-Man-
, laid with 2" lap, tho.foughly cemented wifh: Johns- ville Asphalt Cement. -Roofing to be laid cross-
Manyille Lap Cement and nailed, with galvanized wise of barge. .
150
CRMC-003514
Johns-Manville Service to Railroads
An installation for M. L. Shoemaker, Philadelphia, Pa. Note the neat gray finish and the continuous horizontal. arid vertical lines made possible by the special cut corner
construction.
Johns-Manville Transite Corrugated Asbestos Roofing and Siding
A PARTICULARLY economical, dur- strong sheets of solid mineral. It is ideal
able and fireproof roofing and sid- for many conditions, particularly on low
.ing .for application directly , over .buildings over boilers and where sustained
purlins or girts in skeleton frame construe^ high temperatures or condensation and
tiori, or over wood sheathing;
corrosive fumes make the use of ordinary
A material that will, not rot,trust or corrugated roofing impractical and expen-
burn; that never needs paint; that is im- sive. Transite Corrugated does not warp,
mutie to alkalies, gas fumes and most 1 crack or peel. It is unaffected by temper-
acids. A rigidj corrugated slab of mineral ature differences. It is: practically inde-.
that actually grows tougher with age.
structible and this fact assures the long-
Made of Asbestos'fibres and Portland est, most economical and satisfactory ser-
cement molded under great hydraulic vice,
pressure into dense, tough, structurally
Can be used on Spans up to 45 inches
Because of its unusual strength, Transite Corrugated Asbestos Roofing and Siding can be laid on spans up to 45" directly on the purlins or girts. Our en-
gineers may be able to help in making a substantial saving of structural steel where a building has not yet been erected,
151
CRMC-003515
Johns-Manville Service to Railroads
Economically, Quickly and Easily Applied
Johns - Manville Transite Corrugated Asbestos Roofing and Siding has none of the disadvantages of metal roofing, which is always liable to rust or corrode and al low water to drip in on valuable stock or machinery.
The history of a metal roof is one of expense for constant painting and patch ing and within a few years, replacement. When once erected the metal sheathing cannot be painted between the laps, under flashings, or on the underside where it rests over the purlins or girts. It is at these vital points that rust starts. The metal becomes thinner and thinner and finally gets beyond repair.
The history of Transite Corrugated As bestos Roofing and Siding, on the other hand, is one of long life, low cost and min imum upkeep expense; It never needs paint or other protection to help it keep
its original structural strength--in fact it actually grows tougher with age.
Johns - Manville Transite Corrugated Asbestos Roofing and Siding requires no special tools for application and can be in stalled as rapidly and in the same general way as other corrugated material. It can be readily sawed, punched or drilled and fastened with bolts, nails or screws, as shown on page 156.
The extra width of the sheets in which this material is furnished requires the handling of fewer sheets and the making of fewer laps, thus permitting a substan tial saving in labor and materials as com pared with ordinary corrugated roofing.
Johns - Manville Corrugated Asbestos Roofing and Siding presents a clean, neat, gray finish which lends an attractive ap pearance to the building.
Where Used
- Reco-rnrnended fqr use on engine houses, bridges over tracks, or any place where
boiler houses, chemical and fertilizer, roofing or siding of this type can be used,
.plants* warehouses, .piers, coal; .bunkers, .. On sawtooth robf construction it pro-
. hangars, oil houses,; elevators, . boating vides a maximum of light reflection into
plants,- garages* car .barns, train: sheds, the interior of the buildirig in addition to
.awriings and sheds overloading platforms, durability and economy. .
bridges between buildings, covered
, !.
152
CRMC-003516
Johns-Manville Service to Railroads
Cut Corner Construction --A Feature
A feature of this mate rial is the manner in which sheets are butted and lapped at the corners, which is provided for by special cut corner con struction. These cut cor ners eliminate a thickness of material where the four sheets come together in the corner lap, thus allow ing the sheets to nest per fectly at these points, per mitting them to be laid with laps forming contin uous horizontal and verti cal lines. This improves the appearance and elimi nates cutting of sheets at one end of thebuilding; The inside add outside radii; of ' the corrugations are the . samej thereby, allowing the.. sheets to . nest perfectly-at all laps.O'..' All of the foregoing fea- . tures pr ovide . a; more weathertight, watertight . and better looking job than is possible with any ::: similar type of roofing.
Our engineers will be glad to go over plans and discuss, the use of Transite Corrugated for new build ings, or for the replace ment of roofing and siding on buildings already in service.
How Furnished
Johns-Manville Transite Corrugated Asbestos Roofing and Siding is fur nished in sheets 42" wide,
Bevel Cut Corners of Transite Corrugated
Asbestos Roofing
1. Corner drawn apart. Extra thickness is avoided by butting the two bevel corners in stead of lapping.
2i. Upper-, bev.el. sheet moved : i'nto ..place.
': When , remaining top sheet' is in -position, fhere.; .are ' no crevices
: for:.'the weather: to e.riter.
3. Complete corner. Note the vertical as well as horizontal laps form continuous straight lines, a better looking job than the custom ary staggered vertical lap.
153
and in standard lengths of 4, 5, 6, 7 and 8 ft. Sheets can be furnished, on spe cial order, cut to any de sired length possible from the above mentioned stan dard sizes. Comes in two thicknesses, approximately
and y<l'. This material is smooth on the weather side, the other side being slightly pebbled.
Special Curved Sheets
Where it is desired to use curved sheets, they can be furnished, on special or der, curved at the factory with the following limita tions; sheets may be curved longitudinally, the arc being formed along the direction of the corruga tions. Minimum radius when so curved 48".
Sheets may be curved ; Crosswise,. the arc being formed across the cbrruga-, i tions.; Minimum . radius when so curved 12". Sheets may; be. curved either way. but not in combination;
The' same materials that are used in forming the corrugated sheet are moulded at the factory in to, special standard shapes to be used : as ridge roll, corner roll, louvres and ventilators; see pages 156, 157 and 199. Flat sheets can be furnished as de scribed on page 188. All of the above mentioned materials are particularly designed to be used in con nection with the corrugat ed material, but can also be used independently.
CRMC-003517
Johns-Manville Service to Railroads
Fasteners especially designed for use in connection with this material can be fur nished by us.
This material may be laid on roofs pitched 2" to the foot and over. Where pitches are from 2" to 4" to the foot, Johns-
Manville Asbestos Roof Putty is to be used in all laps. Where pitch is over 4" to the foot this precaution is not necessary unless extraordinary service conditions demand it.
A Tested and Proved Material
Asbestos is a mineral that withstands all the destructive forces of nature. Port land cement is used universally in build ing for permanence. These materials com bined in Transite Corrugated Asbestos Roofing and Siding, make the ideal mate rial for skeleton frame construction.
This product is simply a different form of a time-tested material. It is the same as Johns-Manville Transite Asbestos Wood
which has been used in railroad and in dustrial construction over a period of many years as fireproof roofing and sid ing, partitions, walls, ceilings, in fact, any where a fireproof and durable material is needed.
This tested and proved material is cor rugated to give greater strength thus al lowing for its use as roofing and siding over widely spaced purlins.
This building of the Iowa Southern Utilities Company, Centerville, Iowa, will be free from roof troubles practically as long as the structure stands. The natural gray sur face of this Transite Corrugated. Asbestos Roofing never needs paint or other protective
coating. David F. Fisher & Co., Engineers.
154
CRMC-003518
Johns-Manville Service to Railroads
Standard Specifications for the Application of Johns-Manville Transite Corrugated Asbestos
i
Roofing and Siding
ROOFING AND SIDING
enabling material to be laid with side laps form
Where shown on plans, the roofs and sides of building shall be covered with Johns-Manville Transite Corrugated Asbestos Roofing and Siding
ing vertical lines. Sheets shall be laid with 6" end-lap and two
corrugations side lap.
as manufactured by Johns-Manville Inc. The FLASHING (AND BUILDING TRIM)
i
material to be of a dense, homogeneous construc
Where shown or indicated on plans Ridge Roll,
tion, weighing approximately 3.5 lbs. per square Corner Roll, Louvers and Flashing to be of the
foot, and to be approximately
thick at ridge same material as the roofing and siding. All other
and valley of corrugations and approximately y
flashing to be of 4 lb. Sheet Lead.
thick on slope.
FASTENERS
When J/i" material is to be specified cross out above data on weight and thicknesses ONLY and substitute
Johns-Manville Standard sheradized or galvan
the following:
ized Fasteners shall be used. Heads of all fasten
Weighing approximately 7 lbs. per square foot, and to be ers on weather side of building shall be protected approximately $4" thick at ridge and valley of corruga with Johns-Manville Asbestos Roof Putty.
tions and approximately l/i" on slope.
METHOD OF APPLICATION
Sheets shall be 42" wide and of suitable length
The method of application shall be in strict
.so that all end-laps shall occur over a purlin or accordance with the manufacturer's standard
girt. Sheets shall be furnished with cut corners erection instructions.
Types of Johns-Manville Transite Corrugated Asbestos Roofing and Siding, (/" thick) Louvres, Ridge Roll, etc.--Drawing AW-1. 155
CRMC-003519
Johns"Manville Service to Railroads
Tgcei'A ridye ro//
OSfiAOsrr.&Sr. o^'A4s"c~e2sn'"*k^^css-/o*aicAefdrs
s"e/>om. G.I--on each sSe'e.
XrkcfooTty (gray) may
be ose</ tf regu. `
/
Pars.-long Softant/ Jagg/e az sfiotvr? 6e6>uj moy he
used if c/esired.
UP--j/b*7eCsTobrrs. TWrooncsct/'/?
C. / P/jn/er -/ t/om.
ype U ooTfen 6" /ong: --.
' \ ^V /Butt'joint....
Tupe ld_ ridge rc /J51DF. VIEVS OF Rip<5.& BATTS//
lypeU boT/en sTd 6>"/ongxTh 7o /// ouer 6*6" Type Xd BaT/en 7o 6s 6o/fed 7o_ ridge sec7rorrs^
T,;/puffy-?-zg
4i.c\7,j97*\ lana ia> ? - 3~'?&/*-j
Type V -- sfosK/*/'^S-3"
Co/a Jr9P iVaiAer -/pdon
Jiwon'aofftXiz$ X J 7& -- c
aacu>ra/u bo/?9^ to r~oa~* n>
7ype (V ridge ro//.
tff'O'fang a >f /t>
,
*'4>cnr fo &C>*anj.
/ roof puTT'! my ;/r of Sftr/pa fX,"'* Vfismcc/.
Type X/ ridge ro!/ -0~ Tong X - 'fb. x 6"*. 6 "
totngs -- sections
6<jT7e</ /a<je/6er
4-_ >o/Ts psr boT/en f/z teach tsidej
/S' * ^rzneratd /"dtom. G / cuazber
eacn side. Gray poo/pu'77ty ooer.
This s us fen of Ridge feo/i is odjusTab/e To ony pifchr
Ridge Roll for Johns-Manville Transite Corrugated Asbestos Roofing and Siding. Drawing AW-3. 156
CRMC-003520
Johns-Manville Service to Railroads
A// Corner- X?oft to hove buff joints os fo/touis -- A--&utt joint, may be covered ur/ft type (J hotter) ffor 6x6" "type ht)set m grot/ roof putty ~7~he top s/tde of batten to be poinfed~vp ui/tti gray roof
pet ftj/ as sbo tun B --Between The butting ends of corner ro// insert a sheet /each si// about 6" uuide (or more if necessary) mode of *5* Jb. /ead -Some to be carried up inside of top. ro// earned thru joint and brovq/t
dacon oner outbids of bottom ro// oboad -s'-' to be botted To ~/op ro//
os shocun.
______ .
...................................... ___________.__________________________________________
CRMC-003521
Johns-Manville Service to Railroads
Men/for roof. ^00000000
/`lain roof.
Shapes of sheets usee/ above.
00
2! --App/teJ fie-gt.
. /tea rocona^ ot/erfapp/rtg **/ 7Z+c co^^g.
43.. ~4pp//c<f fcusTh--over #j2 a/fc/ C*3om. e/
4*J2.
J-M LAP -- PATEftT APPLIED FOR
00S0B000 JZ7Lt;Zr ^ 00000000
reef
B0000000 3/ieeTs regci/rcc/ for >ui/efir>g
os s^Oujn.
4
T^url/p
*ss'?re'ms requirec/ per-s/teef for roofing.
PttMOS or CVTTIh'G BEVEL COZYSP.
fibre-/f rails are usee/ theef
ekou/d be spoccc/ every o7uer corrugation.
Details of Application,;d Johns-Manville Transite Corrugated Asbestos Roofing atid
and Siding--Drawing AW-7. 158
CRMC-003522
Johns -Manville Service to Railroads
UNITED STATES GOVERNMENT BALLOON HANGAR, SCOTT FIELD, ILL.
- -
. Erection supervised by. Construction Quartermaster.
This is one of a number of balloon hangar installations on which the in sulating value, of Asbestos Protected Metal plays an .important part and - assures strength, ' long life and freedom from maintenance expense. The United States Government is a large and regular purchaser of this
product.
Asbestos Protected Metal Roofing and Siding
HIS is another type of corrugated asbestos roofing and siding. Like Transite Corrugated Asbestos Roof ing and Siding described on pages 151 to 158, Asbestos Protected Metal is intended for use over skeleton frame construction, or wood sheathing. However, these two materials are distinctly different in ap pearance and general characteristics. They are made of different elements and in a radically different manner. Asbestos Protected Metal is a light, strong, permanent, acid, alkali and weath erproof building covering. It is easily handled and can be erected without regard
to weather conditions. Its long life, insu lating qualities and the elimination of painting and maintenance costs effect large financial savings.
Asbestos Protected Metal combines in one product all the merits of both corru gated metal and the best built-up roofing. In effect it is a corrugated steel roof on which a perfectly made built-up roofing has been applied at the factory to both surfaces under exact heat control and exact pressure.
Asbestos Protected Metal has many times the insulating value of corrugated steel. This is the reason, as shown by ser-
159
CRMC-003523
Johns"Manville Service to Railroads
vice tests, that buildings on which it is used in tropical countries are so much cooler and more comfortable to work in, as well as more attractive in appearance and more durable. As no thinners or driers are used, the coatings set up hard and tough when exposed to the sun.
In cold countries the insulation results in buildings being easier to heat than those covered with unprotected metals.
The original product has been constant ly improved until today it has a number of exclusive patented features which greatly add to its quality and durability. The pro duct is not new or untried. For many years it has stood the test of service on buildings where conditions are the most severe that can be encountered.
The foremost American, Canadian and foreign industries have used it exclusively under a great variety of conditions for new construction and for replacing other old or wom::out materials: The ease and speed with which it rhay be erected and; freedom from Jitter allow continuous plant opera tion, ^making it; specially desirable for re newals.
permanent construction at a price that ma terially reduces overhead charges.
The base, or core, of Asbestos Protected Metal is a specially annealed steel sheet. The surface is thoroughly cleansed of rust, grease, moisture or any other substance that might interfere with the perfect bond ing of the three protective coatings. The sheets, or shapes, are then immersed in the first asphaltic coating. When the asphal tic coatings are applied they are all heated to definite and uniform temperatures.
How Asbestos Protected Metal Is Manufactured
A SBESTOS Protected Metal is made /-V by combining steel sheets, (of 18, 20,
22, 24 or 26 gauge) asbestos and three different asphaltic compounds, each being prepared to meet a different require ment. They are the result of seventeen years' experience, together with investiga tions by able engineers and chemists and by the foremost chemical research organi zations. Considered from either an erec tion or maintenance viewpoint Asbestos Protected Metal offers building owners
Sample of Asbestos Protected Metal with portions cut away to show relative position of the three corrosionproof and insulating coatings with steel base or core.
160
CRMC-003524
Johns-Manville Service to Railroads
The first asphaltic coating forms a thick, special process before leaving the factory,
elastic, gas and moisture-proof shield that so that no metal is exposed.
entirely encloses the metal., The coating is soft, the asphaltic base containing oils that help to keep it "live" and at maximum effi ciency long after ordinary coatings have outlived their usefulness. This coating is then completely encased with a tough sheet of asbestos felt thoroughly impreg
Asbestos Protected Metal can be fur nished coated on both sides with aluminum paint. This finish has the limitations of other paints in wearing qualities but fur nishes an excellent priming coat for suc ceeding paintings.
nated with asphalt.
Specially selected asbestos fibre is used in the manufacture of this second, or mid dle, coating. It is made by a special pro cess, and is so constructed that it can be impregnated with the asphalt to the best advantage.
The asphalt impregnated asbestos felt is laid over ,the still hot first , coat and forced against it under.heat and pressure in such .a way that the steely the first coat and the asphalt impregnated asbestos felt -
Corrosion Proof
The great resistance of Asbestos Pro tected Metal to corrosion under the most severe conditions that industrial and rail road buildings encounter is important. It is impervious to moisture, salt air, mine water, condensation, acid and alkali fumes, even in combination with high humidity, coming in contact with it from either in side or outside the building.1 Now that the destructive.force of corrosion is gaining recognition the resistance: of Asbestos
are thoroughly" and permanently bonded. Protected Metal to this destructive action
The felt forms ail opaque insulating cover is becoming more appreciated.
> ;:
ing and protects the first coat from light,
Corrosion is Sometimes called "theslow
v.heat and mechanical abrasipn. On the two fire." Although less spectacular than: fire
side edges the felt: is folded over and both it is now believed to cause even greater
ends are closed so that the first- coat is her-:, losses--and they are not covered by insur
metically sealed.:
.A V.v;-S:
. VA'>. ance. It is intensified by sulphuric, bold,
A ; Finally the asbestos coating is protect-', sulphurous, acid, hydrochloric acid and
ed from mechanical abrasion by an ex^/ ammonia compounds contained in soot.
: elusive patented / waterproofing. - This' Wherever coal is burned these elements
waterproof - coating, either black or ma roon, as Ordered, is applied at a high tem perature to: the asphalt impregnated as
are created, so that plants located in
"pure" country air generate their, own de
structive elements.
....
bestos felt forming a tough- and elastic The University of Pittsburgh investiga surface that allows the material to be tion showed losses due to the destructive
handled freely in shipment and erection action of smoke in this country each year
without damage to the protective coating. exceeding the cost of the Panama Canal,
This coating is not affected by natural and that if the acid content in smoke from
temperature changes. It is easily handled Pittsburgh chimneys, alone, in one year
in summer, as it does not melt; and it will acted entirely upon structural steel 265,000
not chip or crack in cold weather.
tons would be dissolved.
Where necessary to cut sheets for build Much of the building part of this in ing trim, ventilators, skylight metal parts, vestment loss can be prevented by the use etc., all exposed edges are treated by our of Asbestos Protected Metal.
161
CRMC-003525
Johns-Manville Service to Railroads
Roof Pitches
Asbestos Protected Metal corrugated sheets can be used on any roof pitch on which other corrugated sheets can be ap plied. Where the pitch is less than 4 inches in 12 inches both side and end laps should be laid in asphaltic cement. Cor rugated sheets should not be used on roofs with a slope of less than 2 inches in 12 inches.
Forms and Sizes
Asbestos Protected Metal is made in a variety of standard forms and sizes which good practice has demonstrated to be most useful, economical and attractive in the general run of construction work. Besides roofing and siding sheets we supply ridge caps, flashings, louvers, ventilators, sky lights,made of Asbestos Protected Metal.
Corrugated Asbestos Protected Metal sheets are 27%" wide and are. carried in stock lengths of even' feet from 5 to '12 ft. inclusive. They have 10% corrugations each 2%" wide and %" deep. They have a net covering width of 23%" with 1%
corrugations side lap. See drawing on page 164.
Standard Mansard sheets possess ar chitectural advantages for both roofing and siding purposes. It is a sheet 27 %" wide showing five beads, each bead meas uring 2" wide by %" high. Sheets are made in lengths of even feet from 5 to 12 ft. in clusive with a net covering width of 24" per sheet.
Standard flat sheets are 30" wide and furnished in lengths of even feet from 5 to 12 ft. inclusive. They are also made in widths less than 30" for special purposes. They may be used for interior sheathing where desired. Also for making ventilat ing flues, ventilators, acid fume ducts, hoods, conveyor boxes, light partition walls, flashings, etc.
Standard fasteners for various types of construction are furnished as required.
The constructioh engineers at our near est branch: will be glad to go over, your plans or confer with you personally ; on roofing or .siding problems in connection with buildings of any type or size .
Standard Specifications for the Application of
tecfed Metal
ROOFING
All roofing shall be of...;........... Corrugated Asb.estos .Protected Metal.
gauge
SIDING'
'! '
All siding shall be of...................................:Sgauge Corrugated Asbestos Protected Metal.
^ , ( Maroon Color to be )(Black
(Maroon Color to be
(Black
Sheets shall be laid with one and one-half cor rugation side lap, and not less than 6" end lap. Manufacturer's Standard Fasteners shall be used and the method of application shall be in strict accordance with the manufacturer's Standard erection instructions. All flashings and ridge cap shall be of................................ *gauge Asbestos Pro tected Metal and of same color as the roofing.
Sheets to be laid with one and one-half corru gation side lap and not less than 4" end lap. Manufacturer's Standard Fasteners shall be used, and the method of erection shall be in strict ac cordance with the manufacturer's Standard erec tion instructions. All flashings shall be of ............................*gauge Asbestos Protected Metal and of the same color as the siding.
No. 18-20-22-24 or 2G gauge depending on pwrlin or girt spacing. See page 1C3.
162
CRMC-003526
Johns-Manville Service to Railroads
Supporting Purlin and Girt Spacings
For Corrugated Sheets on roof structures hav ing a rise of 4" or more in 12", supporting purlins may be spaced as follows:
No. 26 gauge for spans up to 3'9" centers. No. 24 gauge for spans up to 4'9" centers. No. 22 gauge for spans up to 5'9" centers. No. 20 gauge for spans up to 6'6" centers. No. 18 gauge for spans up to 7'6" centers.
Corrugated Asbestos Protected Metal Sheets for Siding, the supporting girts may be spaced as follows ;
No. 26gauge for spans up to 3'10" centers. No. 24gauge for spans up to 4'XO" centers. No. 22gauge for spans up to 5'10" centers. No. 20gauge for spans up to 6' 8" centers.
Gauge
26 24 22 20 18
WEIGHT OF ASBESTOS PROTECTED METAL IN POUNDS PER 100 SQUARE FEET OF MATERIAL AREA
ALL WEIGHTS SUBJECT TO VARIATIONS
Black
CORRUGATED OR MANSARD
Net For Crated Shipments Add
Maroon
Domestic
Export
138 144
14
165 171
15
192 198
16
218 224 ' 17
272 278
20
20 21 22 24 30
Black
FLAT
Net For Crated Shipments Add
Maroon
Domestic
Export
128 154 179 204254
134 160 185 '210 . -260.
10 11 12
13 16
16 17 18 21 25
Estimating Data--Method of Estimating Quantity
. Areas of Asbestos Protected Metal Sheets may
It is, however, .always' desirable to submit
be figured by multiplying thej total added, length ^sketches or blueprints, so. that, the correct quan
of a number of sheets'by the width, of a .sheet.
tity and gauge of sheets,, as well as flashing and
' The standard corrugated and mansard sheets . fasteners can be estimated. Blueprints will be
are27}4 inches wide, which is 2.3 feet.
returned with our estimates, when: requested.
Therefore the total area of sheets given in the
following example is as follows: ,
:
Number of Sheets 30
30 60
Length. . 6'0" :
9'0" .
io;o"
Total Feet 180 270 600
Total Linear Feet ... . 1050 V2.3
3150 2100
Total Material Area. .2415.0 sq. ft.
Standard Flat Asbestos Protected Metal Sheets are 30 inches wide, therefore the added length of a number of sheets would be multiplied by 2yz.
To obtain an approximate figure on corrugated Asbestos Protected Metal required for roofs and siding add 25 per cent, to the actual building area. This takes care of all end and side laps.
SECTION THV.OVCR MONITOR
ALTERNATE SECTION AT EAVE
163
CRMC-003527
Johns'Manville Service to Railroads Standard Building Details
CRMC-003528
i
Johns-Manville Service to Railroads Standard Building Details
165
CRMC-003529
i
Johns-Manville Service to Railroads Standard Building Details
166
CRMC-003530
Johns-Maiwille Service to Railroads
The artistic appearance, durability and positive fire protection of Johns:Manville Rigid Asbestos Shingles make them ideal lor railroad passenger j' stations-and other railroad buildings. They last the life, of the. building
and never require painting or other maintenance.
Johns-Manville Standard and Colorblende Asbestos Shingles
N. the planning:-.of-modern railroad ter- such a variety of sizes, shapes and colors
I minals and suburban, passenger sta-- as to offer the widest range of artistic and tions, railroad Y.M.C.A.'s and similar interesting roofing effects and to provide
buildings, the architect or engineer de- the utmost in service, economy, fire and
mands a roofing that combines beauty weather protection.
with fire protection and durability. He Made of Asbestos Fibres and Portland
demands a roofing material that will retain Cement united under great hydraulic pres
its artistry and effectiveness indefinitely sure, Johns-Manville Rigid Asbestos Shin-
and serve with the same maintenance gles cannot rot, rust or burn. They do not
economy as the stone and steel of the foun- warp, curl, split or shale. They are not as
dation and walls.
heavy as slate or tile. They are simply
Such a roofing material is the Johns- a combination of rock with rock--an ever-
Manville Rigid Asbestos Shingle, which is lasting roofing material that never needs
truly the Aristocrat of Fire-Safe Roofings, paint and lasts as long as the building it
It is a solid slab of mineral that is made in protects.
167
CRMC-003531
Johns-Manville Service to Railroads
Add Distinction and Dignity to the Building
Whether the roofing should have the simplicity of straight lines, the rugged ir regularity and pleasing shadows of heavy butts and rough edges, a bright over-all tone of one color, or a mellow, weathered appearance, the architect will find in the variety of sizes and shapes, the two dif ferent surface textures as well as the color ings of Johns-Manville Rigid Asbestos Shingles an opportunity to obtain just the roofing effect desired.
He can obtain a pleasing harmony or a distinctive contrast, as the style of archi tecture, the sidewall treatment, the size of the building or natural environment may dictate. These shingles give a distinc tion and interest to the building which is quite impossible with roofings confined to fewer shapes and colors.
The color plates shown on pages 171 to
174 represent only a few of the combina tions which can be obtained with JohnsManville Colorblende shingles. It is quite impossible to reproduce the peculiar charm of a Colorblende roof in its proper setting but these plates will show its at tractiveness and how it may be adapted to particular conditions.
The various shades of a Colorblende Roof of Conglomerate Brown alone, or with the Natural Gray or Indian Red add ed, may be laid at random or in accordance with a predetermined pattern or color scheme, the results of both these plans be ing shown in the color plates.
Our Architects' Service Department will be glad to confer with architects about the use of either Standard or Colorblende As bestos Shingles for any type of building.
Colors, Sizes and Shapes
The color range of. Johns-Manville. gles are made in one size only, 9"xl8",
Rigid Asbestos/ Shingles includes: a soft/,
thick, rough edges, No. 50 or No. 52.
Natural Gray, an Indian Red, an Autumn
The three shades, Indian Red, Natural
Brown arid a composite known as Con Gray and Autumn Brown are known as
glomerate / Brown. The Conglomerate . /Brown, blend is made'up of four separate shingles, each representing a different shade of brown, thus producing a subtle, pleasing blend, which can be used alone or
Standard Asbestos Shingles and are made in y8" thickness with smooth edges and in *4" thickness with rough edges, in the sizes and shapes shown on page 176 and in the tabulation of construction data on
in combination with Red or Gray. All six page 169.
of these shades are made in either smooth
or rough surface. The rough texture is The Natural Gray, Indian Red and Au
particularly appropriate with face brick tumn Brown Shingles, in both and 34"
side walls or on buildings of the Spanish thicknesses are not blended one with the
Renaissance type.
other but are intended for use when a solid
To the Conglomerate Brown Shingles, over-all roof tone of soft red, gray or
(either smooth or rough texture) when brown is desired. Where a mottled or
laid alone, or with any proportion of Colorblende effect is preferred the Con
Indian Red or Natural Gray, the regis glomerate Brown shingles alone or mixed
tered trade name of `"Colorblende" has with Indian Red or Natural Gray should
been given. Conglomerate Brown Shin be chosen.
168
CRMC-003532
Johns-Manville Service to Railroads
Ideal from Every Standpoint
On account of their practically inde B, when laid Hexagonal method. They can
structible nature and their permanent col be applied by any roofer, slater or carpen
oring, Johns-Manville Shingles do more ter according to any of the various meth
than express the artistic ideas of the ar ods in vogue,--American, Hexagonal or
chitect for a short time. They maintain Diagonal (French) on roof decks of ordi
their original beauty indefinitely. They nary design.
do more than merely cover a building-- The Hexagonal or "honeycomb" method
they protect it against all weather condi of application is much more artistic than
tions--they require no painting or similar the Diagonal method. In the Hexagonal
maintenance and they are fireproof. This method apparently six sides of the shingles
is of particular importance in railroad are shown thus overcoming the objection
building on account of the prevalence of to severely straight lines and producing a
flying sparks and hot cinders.
more pleasing effect. It is not only more
Whether the first consideration in the choice of shingles is their artistic fitness-- their fire protection and weather protec tion or their economy and permanence,
attractive but affords better protection, due to the fact that the overlap at the lower ends is greater. For illustration of various methods see pages 175 and 176
Johns-Manville Rigid Asbestos Shingles Johns-Manville Asbestos Shingles are
meet every requirement.
covered by the policy of roof registration
They are approved by Underwriters' described in detail On page 119.
Laboratories, Inc., and are labelled Glass Construction data, drawings and detail
A, when laid American method and Glass' specifications are included in this section.
Data on Johns-Manville Rigid Asbestos Shingles
Catalog
Number Size of Main . (Ins.) .Body
Shingle
. Thick ness.
: Approx.
. Weight. per 100
.Shingles iLbs.'..
Aoprox,. Weight per Sq. Applied
Lbs.i
Number Surface Shingles, Exposed per Sq. (Inches **
*3 M* *5 *6*
9
12
*50f
*S2t 60
12x12 12x12
8x16 8x16
16x16
1 v" ' 1 <"
i v "
l _
\s."
12x12 1 s "
9x18
9x18
12x12
\'
V
1 V '
215 205 . 185 175
.
343
200
515 495 480 455
300'
320
320 650
320 740
200 320
300
240 . . 5X12 240 5x12 260 . . 7x8 260 7x8
87 13x13
160 91jx91 <
204 230 160`
8x9 18x3!j 91 vx9 ' >
No. of .
GMvt
' No. of Storm
Sections Ridge
Catalog
Nails Anchors
Number
per sq. ReLbs. . quired
quired
of Starter
- per Sq. Lin. Ft.
lap
No. of Starters
Required per 100 Lin. Ft.
Method of
Laying
2'.y 93 51 I'd"1-. . 67 American
2
' 93 - -51 i"
67. American
2>
93 51
67 American
2.
93 51 S
67 American
1
87 ,
93
17 i V' / 75 1 1'1 s " 1 67
Diagonal
1j
160
93
17 1 1 ,| "1 14 ( ' s"i
75 89 Diagonal
2
93
17. V* 51 i V
75 67 American
2j
93 51 t
67i Longitudinal
l;
160
93
17 < ' 4 ' 61 l',"'
75 77 Hexagonal
l
87
93
17 i , ") 71
75 58 Hexagonal
NOTE.:--With this style cf shingle we recommend Bostcr. -,r Chicago) Hip and Ridge: when used with No, 50 or 52 Shingles allow about 1?. squares extra of No. 50 Shingles i'.r every 100 lineal feet to be covered. When used with Nos. 3, 4, 5 or 6 Shingles allow l:j squares extra of No. 5 for every 100 lineal feet to be covered.
f Conglomerate Brown (blend) furnished only in the Nos. 16 and 52 Shingle sizes. No. 52 is punched and intended for application by the horizontal method fthc long dimension paraiieiir.g the eaves).
* Numbers so marked have clipped corners.
i Order 35 No. 51 starters and halve the long way to get the C7 starters (4';" :: IS"'i.
169
CRMC-003533
Johns-Manville Service to Railroads
For Re-Roofing Over Old Wooden Shingles
,A.-most practical and satisfactory way of .fireproofing, and weatherproof ing an.old wooden shingle roof. It not only saves time and expense but avoids the dirty job of ripping, off the old shingles. It also eliminates . painting and similar maintenance expense and the building has been
RE-ROOFED FOR THE LAST TIME.
.
N- old shingle rpof, particularly on a Another advantage is.that the retention
A railroad building, is a decided liabil- of the old shingles, provides a double roof ity, not only Oil account of the- fire, which makes a building cooler in summer
hazard but'the.constant, painting and raend warmer in winter.
,.
pairs which it requires. ' When it must be' replaced the work
can be done, for the last, time, and time, money and labor saved in the operation by the application of Johns-Manville (Rigid) Asbestos Shingles.
No longer is it necessary to rip off the old shingles. All the dust/dirt and delay can now be eliminated.
The old shingles can be left just as they are and Johns-Manville Rigid Asbestos Shingles applied right on top of them. This is the quick, clean, economical and perma nent way to re-roof. It quickly transforms
When it comes to the replacement of an old wooden shingle roof on any building apply Johns-Manville Standard or Colorblende (Rigid) Asbestos Shingles right over the old ones. The building will be re-roofed for the last time and perman ently protected from fire and the elements.
Over old shingles as well as on new roofs Johns - Manville Rigid Asbestos Shingles are given highest ratings by Un derwriters' Laboratories, Inc; Class A for the American method and Class B for the Hexagonal.
a dilapidated wooden shingle roof that is a Note: When rigid Asbestos shingles
constant menace into one that is positively are applied over old wooden shingles spec
fire-safe and good looking.
ify 2" nails when ordering.
170
CRMC-003534
fireproof roof of Johns-Manville "Colorblende" Asbestos Shingles makes a pleasing contrast to the wails of red brick and white mortar. 1 he varied combinations in which these shingles can be laid offer many pleasing effects for every type of building where a colorful roof is desired.
171
CRMC-003535
_jXOTHER colorful roof oj * x indestructible Johns-lMa/reilh- the fireproof, 'll'eat h erp ro of. p ru ctirally
Colorblende Asbestos Slutujles. the planting is admirably topped off by the subtle slunl-
' s--one zchit'h ~eill please the most exact i;?//.
CRMC-003536
a a rtw
JDL'ILDIXGS covered oath Jo hus-Manville " Colorblende" Asbestos Shmrjles are distinctive because oj ike beauty of color oj their roots.
When, also, the endurance and fire-safety of "Coiorhlcnd<" S!nu</lcs are considered they become doubly desirable ivhen buildina for permanence.
17
CRMC-003537
the. plain severeness oj .:co walls is relieved by the lively color roof of J ohns-ISIanville S Jorblende" .dshestos Shingles.
These everlasting shnu/les are v texture, as suits the individual to.
with either smooth or rough surface ' particular architectural scheme.
:*4
CRMC-003538
Johns-Manville Service to Railroads Details of Application of
Johns-Manville Asbestos Shingles
Sketch showing application of Johns-Manville Asbestos Shingles, American Method.
NOTE:--The sketch is correct in detail for the application of No. 5 and No. 6, 8" x 16". Where the No. 50, 9" x 18" shingle is to be applied No. 17 is the first starter, followed by No. 51 as a second starter, outlined
. in specification at top of.page 177.
Sketch^showing application of.' iJohns-Manville Asbestos -^Shingles, Horizontal Method.
Sketch showing application of Johns-Manville Asbestos Shingles, Hexagonal Method.
175 CRMC-003539
Johns-Manville Service to Railroads Details of Johns-Manville Asbestos Shingles
Hexagonal' Shingle^--Showing. Application' of . Storm
"V .
Anchor... . Enlarged:. Scale.'
Standard Shapes
176
CRMC-003540
Johns -Manville Service to Railroads
Specifications for the Application of Johns-Manville Standard and "Colorblende" Asbestos Shingles
American Method "Colorblende"* Asbestos Shingles (No. 50, 54" chick, rough edge)
Lay roof boards in the usual manner, breaking joints and nailing securely in place with at least two nails at each rafter, leaving no loose ends. The roofing boards shall be well seasoned, of narrow width and uniform thickness; tongue and grooved preferred. Over the roofing boards lay one thickness of Johns-Manville Asbestos Slat ers' Felt, laying horizontally with a 4" lap, and with 12" lap on ridges, hips and valleys. (See detail on page 175.)
Apply J4" thick x 134" wide furring strip parallel with and flush with the eaves, then apply one course of Standard.(Brown)* No. 17, 4" x 16" Starters, at eaves lengthwise and parallel to same, overhanging the eaves about 1". Apply, second starter course using Standard (Brown)* No. 51, 9" x 18" Starters, at eaves lengthwise and parallel to same, breaking joints.with and entirely cover ing the first starter: course. Then apply first main body course using'Conglomerate Brown* No. 50; 9" x 18", and (Indian Red* No. 50.9" x 18") (Nat
ural Gray* No. 50, 9"xl8") (mark out color not to be considered) Johns-Manville Asbestos Shingles, breaking joints with and entirely covering the starter courses; after which proceed in the regu lar manner as with wooden shingles or slate, ex posing 8 inches to the weather and fastening each shingle in place with two galvanized iron (or copper) needle pointed shingle nails. Never drive the nails down tight; it is only necessary to drive them firmly.
The various shades of "Colorblende"* Asbes tos Shingles shall be laid at random.
HIPS AND RIDGES
Construct "Boston" (or "Chicago") Hip and Ridge using No, 50 Johns-Manville Asbestos Shingles--(color.to be as selected). -
FLASHINGS
' Flash all chimneys, ..valleys,: etc.,, with copper or other approved material'.
American Method
(Shingles Laid Horizontally) .'A
<fCdldrblende"*-Asbestos Shingles (No. 52, 34" thick, rough edge)
When this specification is used, begin it by re exposing 354" to the weather and fastening each
peating the -first ..'paragraph, regarding' the roof shingle in' place with' two--galvanized, iron (or
deck; of the-Specification above, continuing as follows: copper) needle pointed shingle nails. Never drive
Apply 34" thick x 134" wide furring strip the nails down tight, it is'only necessary to drive parallel with and flush with the. eaves, then apply them firmly.
one course of (Brown) 434"xl8'^: starters, (these to : The various shades of "Colorblende"* Asbes
be made on the job from No. 51, 9" x 18" starters) tos Shingles shall be laid at random.
at eaves lengthwise and parallel to same, over hanging the eaves about 1". Then apply first main body course using Conglomerate Brown* No. 52,
HIPS AND RIDGES
Construct "Boston" (or "Chicago") Hip and
9"xl8", and (Indian Red* No. 52, 9"xl8") (Nat Ridge using No. 50 Johns-Manville Asbestos
ural Gray* No. 52, 9"xl8") /mark out color not Shingles--(color to be as selected).
to be considered) Johns-Manville Asbestos Shin gles breaking joints with and entirely covering the starter course; after which proceed in the
FLASHINGS
Flash all chimneys, valleys, etc., with copper
regular manner as with wooden shingles, or slate or other approved material.
*ifhen Johns-Manville (/'l . I sixains Shinnies are to he hud in one color, omit the word "(hdorblende in the above .s//cJWficolions. Insert the desirctl color nhere reijuired.
177
CRMC-003541
Johns-Manville Service to Railroads
In the jollotcing specifications reference is made to definite sizes and styles of shingles. fl here other sizes end styles are to he specified, insert color, size, style number and weather exposure as desired. (See pages 169 and 176 for necessary data.)
American Method
Standard. Asbestos Shingles (No. 3, No. 4, No. 5 or No. 6, } s" thick, smooth edge).
Lay roof boards in the usual manner, breaking joints and nailing securely in place, with at least two nails at each rafter, leaving no loose ends. The roofing boards shall be well seasoned, of nar row width and uniform thickness; tongue and grooved preferred. Over the roofing boards lay one thickness of Johns-Manville Asbestos Slaters' Felt, laying horizontally with a 4-inch lap, and with 12-inch laps on ridges, hips and valleys.
Apply %-inch thick by 1%-inch wide furring strip parallel with and hush with eaves, then, apply one course of No. 51 *(B), 9 x 18 inch starters at eaves lengthwise and parallel to same, overhanging the eaves about 1 inch. Then apply first main body course using No. 5 *(A) shingle, breaking joints with and entirely covering starter course; after which proceed in the regular man
ner as with wooden shingles or slate, exposing 7 inches to the weather and fastening each shingle in place with two galvanized iron (or copper) needle pointed shingle nails. Never drive nails down tight, it is only necessary to drive them firmly.
HIPS AND RIDGES Over the ridges and hips apply Johns-Man
ville Asbestos Ridge and Hip Roll with not less than 3-inch lap, fastened in place with special ridge roll fasteners, or construct "Boston" (or "Chicago") Hip and Ridge, using No. 5 shingles.
FLASHINGS Flash all chimneys, valleys,, etc., with copper
or other approved material.
Hexagonal Method
Standard Asbestos Shingles (Nos. 60 or 70, %" thick, smooth edge).
Lay roof boards in the usual manner, breaking joints and nailing' Securely in' place with two nails at each rafter, leaving no loose ends.; 'The roofing boards shall be well seasonedi of narrow width ahd uniform thickness; tongue and grooved preferred; Over the roofing boards lay one thick- ness of Johns-Manville Asbestos Slaters' Felt* laying horizontally with a. ;4-inch lap, and with
12-inch lap on ridges, hips and valleys. Apply a j4-inch thick by. J^-inch wide furring
strip parallel with and flush, with eaves, then apply one course of No. 17 -(C) starters at eaves lengthwise and parallel to same, overhanging the eaves about 1 inch. Apply second starter course using No. 61 *(B) shingles at eaves lengthwise and parallel to same, breaking joints with and en-
tirely covering the first starter course. Insert
copper storm nails between abutting ends of
shingles of second starter course.
Cover balance of roof with No. 60-(A) 12"xl2", Johns-Manville Asbestos Shingles with copper storm nails protruding through hole in lower corner; these shingles to be laid with their side edges
forming a 45 degree angle with the. eaves. Bend down copper storm nail protruding through the shingle, insert copper,storni nails between abutting corners of shingles; and securely fasten each shingle- in place' with;, two .galvanized iron (or copper) needle pointed' shingle- nails. Never drive nails down tight; it is only necessary to drive them firmly.
HIPS iXD RIDGES 0ver `the ridges and hips 'apply Johns-Manville
Asbestos Ridge and Hip Roll, with not less than 3-inch lap, fastened in place with special ridge roll fasteners
leurvr-e FLASHINGS
Flash all chimneys, valleys, etc., with copper
or ot^er approved material,
DIAGONAL METHOD
The Diagonal Method (No. 9 or 12) Asbestos
Shingles are applied in the same manner as specified for the Hexagonal Method. The foregoing specification will apply by substituting the desired size and style number.
*Refer to sketches on pages 175 and 176 for identification of alphabetical references.
178
CRMC-003542
Johns-Manville Service to Railroads
] Flexstone Asbestos Shingles afford better service and greater fire protection because of their all-mineral, asbes tos rock fibre felt base.
Johns-Manville Flexstone Asbestos Shingles
(Slate Surfaced)
"T TF.THERE for any reason the archi-
VV tect prefers a flexible, slate sur-
faced shingle Johns-Manville
Flexstone Asbestos Shingles are recom-
mended for any size bf building with a roof pitch sufficient to accommodate this type of roof covering.
V * V: , Flexstone Asbestos Shingles are an improved, all-mineral form of the flexible
slate surfaced shingle. There are two types of flexible slate surfaced shingles on the market today. One is the so-called asphalt shingle and the other is the JohnsManville Flexstone Asbestos Shingle. Although quite the same in surface appearance, the Johns-Manville Flexstone Asbestos Shingle is radically different and more desirable because of the basic raw material of which it is made.
Flexstone Asbestos Shingles are Rock--Not Rags
In a modern sky-scraper the strength and everlasting qualities of the foundation determine the durability, safety and usefulness of the structure; so it is with a flexible, slate surfaced shingle.
A shingle cannot be better than its foundation. The felt base is its backbone, It depends for its useful life upon the re sistance of its felt to fire, time and weather. Therefore, the most important thing
179
CRMC-003543
Johns-Manville Service to Railroads
about a roofing of this kind is the nature of the raw materials used in the manufac ture of the felt.
The base of the ordinary asphalt shingle is a rag felt which is partly rags and in some cases partly jute, waste paper and other refuse material. It will burn to a cinder.
The base of Johns-Manville Flexstone Shingles is the same asbestos rock fibre that is used in all Johns-Manville Asbestos Roofings. It is proof against rot, weather and fire.
That is why Flexstone Asbestos Shin gles are superior. The natural durability --the practically indestructible nature of their asbestos felt base assures longer and more economical service and a greater de gree of fire protection.
Flexstone Asbestos Shingles are better, more durable and- more fire-safe because
of what is IN them, rather than because of
what is ON them. And yet they cost little
more than rag-felt shingles.
As for the surfacing: On Flexstone
Shingles the only function of the slate is to provide an attractive, colorful surface rather than a further protection for the felt. Asbestos felt needs no such protec tion. It is not dependent upon any kind of surfacing for its resistance to time, fire and weather.
Flexstone Asbestos Shingles are attrac tive in appearance; moderate in first cost, easy to apply, fire-safe and they will not curl when properly applied.
Flexstone Asbestos Shingles are fur nished with a surfacing of crushed slate in soft Red, a cool Green and a rich Blueblack.
Johns-Manville Flexstone Shingles are approved by Underwriters5 Laboratories, Inc. ASBESTOS SHINGLES ARE THE ONLY FLEXIBLE COMPOSITION SHINGLES that take base rates of insur ance. Flexstone Asbestos Shingles have been labelled Class "B," the highest rating for this type of shingle. Many localities prohibit roofs of lower rating than Class "B."
Made in
(1) Flexstone Rectangular Indi vid u al Shinglessize 8" x424 shingles will cover 100 square feet of surface. Shipped in bundles of % square of 106 shingles, in cluding directions for application. Ap-
proximate shipping weight: 230 lbs. per square.
Mexstone Asbestos
Individual Shingles,
Sl2e 8 x 12^"-
6 lbs. of 1" large head galvanized nails per square required for application.
(2) Flexstone Strip Shingles. A strip of asbestos slate surfaced felt 32" long by
10" or 12%" wide, .notched to represent four shingles. 112 strips: will cover 100 square feet. Shipped, in/bundles of y2 square of 56 strips, including directions for application. Strip shingles are quicker and easier to lay and require fewer nails. Approximate shipping weight 10" width 185 lbs., J-2%" width 240 lbs. per square.
4 lbs. of 1" large head galvanized nails per square required for application.
Flexstone Asbestos Strip Shingles Size 32" x 10" or 12^".
180
CRMC-003544
Johns-Manville Service to Railroads
Standard Specifications for Application of Johns-Manville
Flexstone Rectangular Individual Asbestos Shingles
(Size 8" x 123/")
ROOF BOARDS
Lay the roof boards in the usual manner, breaking joints and nailing securely in place with at least two nails at each rafter, leaving no loose ends. The roof boards shall be well-seasoned, of narrow width and uniform thickness; tongued
and grooved preferred.
MATERIALS
Shingles shall be a heavy weight single thick
ness of asbestos felt impregnated with asphalt, the weather surface to be covered with crushed slate,
same to be Johns-Manville Flexstone Rectangular Asbestos Shingles (red, green or blue-black), size
8" x 1234", laid up in the following manner:
ROOFING
cut into strips approximately 8" wide and applied
At the eaves apply sheet metal drip edge extending 4" each side of hip or ridge. Both edges
(painted both sides), or a wooden strip, over shall be securely nailed with large head galvan
hanging the eave approximately/ 54"-
ized nails at least 1" long. These nails shall be
Line the valleys with sheet metal, or Johns- spaced approximately 2" center to center and
Manville Flexstone Slate Surfaced Asbestos Roof placed 34" from edge.
.
ing. If the.slate surfaced roofing is used it shall.. If the individual shingles are used application'
be applied in two layers,- the first layer being 12" shall be started at either end of ridge and lower
wide and the second or top layer, being 20" wide. : end of hip. Apply one shingle flush with main
Lay the first, or. starting course, of shingles, body shingles, extending 4" each side of hip or
vertically and butted- together, flush: with drip : ridge. Apply another shingle in the same man edge, thus making a solid strip along the . eave, ner and directly , over the first. Apply the next
1234" wide, r;
vv r r-:.
shingle in a similar manner, 4" from the butt of
Lay another starting course,; directly; on top of the first shingle, fastening each shingle with two
- the first and flush with -same;, starting- at the left : large head galvanized nails at least 1" long. These
with a one-third width, shingle (254" X: 1234"), nails shall be placed 5" above the butt and 34"
so 'that all. joint's will. be broken with first starting; from the sides, one either side of ridge or hip.'
course. Space/these shingles :54" apart.
> Apply succeeding: shingles in a similar manner*
Start: the first main body course .at the. end .4" exposing 4" of each shingle- to the weather. .
up, from the eave, with a whole shingle. Start the FLASHING
.next course with - a two:-third : width shingle. Flash and counter flash, where necessary, with
,,(534. x 1234"). Start the third main body course
with a whole shingle, and the fourth course with a one-third width shingle, and so on in rotation,
sheet metal applied in an approved manner.
SIDING
breaking all joints one-third and two-thirds and
Except as hereinafter noted, the specification
spacing all main body shingles 34" apart.
for applying roofing shall apply to Siding:
All shingles shall have a weather exposure of 4".
Allow J4" space around all doors, windows,
etc., to permit shingles to be carried behind face
NAILING
boards, (these face boards shall be put on after
Each shingle shall be nailed to the sheathing the shingles have been applied and shall lap the
with two large head galvanized nails at least 1" shingles at least 2".)
long. These nails shall be placed 5" above the
The shingles shall be exposed 3" to the weather,
butt and 34" in from the sides.
nailing each shingle with two large head galvan
HIPS AND RIDGES
ized nails at least 1" long. These nails shall be
After the main body shingles have been ap placed 4" above the butt and 1" in from the sides.
plied, hips and ridges shall be covered with Johns- Secure the two lower corners of the exposed butt
Manville Flexstone Slate Surfaced Asbestos Roof of each shingle with small copper brads or small
ing or individual shingles.
headed nails.
181
CRMC-003S45
Johns-Manville Service to Railroads
Standard Specifications for the Application of Johns-Manville Flexstone Asbestos Strip Shingles
Lay the roof boards in the usual manner, each cut-out, and one at the end of each strip.
breaking joints and nailing securely in place with These nails shall be placed 5" up from the butt
at least two nails at each rafter, leaving no loose and 54" in from the sides. Center nails shall be
ends. The roof boards shall be well-seasoned, driven first.
of narrow width and uniform thickness; tongued and grooved preferred.
MATERIALS
HIPS AND RIDGES
After the main body shingles have been applied, hips and ridges shall be covered with Johns-Man
Shingles shall be a heavy , weight single thick ville Flexstone Slate Surfaced Asbestos Roofing
ness of asbestos felt impregnated with asphalt, the or individual shingles.
weather surface to be covered with crushed slate,
If the slate surfaced roofing is used, it shall be
same to be Johns-Manville Flexstone . Asbestos cut into strips approximately 8" wide and applied
Strip Shingles (red, green or blue-black), size extending 4" each side of hip .or, ridge, Both edges ;
10" x 32" or 12x 32", laid up in the following shall be securely nailed with large head galvan
manner:- /
ized nails at least 1" long. These nails shall be
ROOFING :
\ ] ' ; spaced approximately 2" center to center and
At the' eaves apply sheet metal drip edge placed 54" from edge. ; '
{painted both sides), or a wooden strip, over
If the individual shingles are used same shall
hanging, the eaye approximately
be cut from, the strip shingles and .application
.. Line ., the , valleys: with' sheet metal, or . Johns- shall be started at either end of ridge and lower
Manville Flexstone Slate Surfaced Asbestos Roof-: end of hip. Apply one shingle flush; with main
ing, If slate surfaced rpofirig is used, it shall be applied in two. .layers, the- first layer being 12"
body shingles, extending each side,of hip or
5 ridge. Apply another shingle in the saniemanner
wide and the second, or top layer; being 20" wide. and directly over the first. Apply the next shin
Lay the first^ .or starting course, of shingles gle in a similar manner 4'- above the butt of the
flush with .the drip edge with the cutouts' up the first shingle and fasten with two large head gal
roof, butting the. strips end to end.
vanized nails at least 1" long. These nails shall
Lay another starting course directly on top of. be placed 5" above the butt and 54" from the
the first and flush with same, with the cutouts sides, one either side of ridge or hip, Apply suc
down the roof, breaking joints. Butt the strips ceeding shingles in a similar manner, exposing 4"
end to end.
of each shingle to the weather.
;
Start the first main body course at the end 4" up from the eave, with a strip from which half of the end shingle has been cut longitudinally. Start the next course above with a full width strip, and so on in rotation to break joints.
All shingles shall have a weather exposure of 4".
NAILING
FLASHING
Flash and counter flash, where necessary, with sheet metal applied in an approved manner.
Siding--Note: Refer to same paragraph in spe
cification for Flexstone Individual Shingle on page 181 and follow same instructions. In writing this specification, copy as part of it the "Siding" paragraph, making the following change: "These
Strips shall be nailed to the sheathing with one nails shall be placed 4" above the butt and 1"
large head galvanized nail at least 1" long above from the cutout."
182
CUMC-003546
Johns-Martville Service to Railroads
Johns-Manville Rag-Felt Ready-to -Lay Roofings
FHILE our Asbestos Ready-to-lay
Roofings are the most satisfactory
and economical .in. the long run,
sometimes `the. matter of first
cost, or nature; of the building,
confines the choice to the. rag-felt ..
type' of roofing,
;
. . To meet this deuiaiid/; Johns-. .
ManVille makes ragrfelt roofings,
and makes them according,to-the
same, high standards of manufac- .
ture that govern the production
of all its roofings. This assures
the best return on the money in- ;
vested no matter what type you
buy.
Johns-Manville Rag-felt Roof
ings are made of carefully
selected, clean rag - stock free
from straw, jute and similar
shoddy. This rag-stock is fabri
cated into tough felts that are
thoroughly saturated, literally
soaked with a combination of waterproof
ing, life-giving, natural asphalts, sealed
into the felt by a heavy coating of the same natural asphalts on both sides.;
The life of rag-felt roofing is largely dependent upon the character of the waterproofing used, so we choose only those that best resist the action of ;the sun' and wear and. tear Of weather; ;; In the selection Of: our asphalts we have no particular one to ex ploit. We compound and process asphalt materials in the light of the, most recent, up - to - date knowledge, without regard to what anyone else is doing or ex ploiting. We own no oil wells; we own no asphalt deposits; we are free to buy and use what experi ence teaches us is best. Therefore, the choice of the asphalts for roof ing is made with the primary ob ject of giving to the felt the max imum protection against time,
weather and water, and to assure longest service with the minimum upkeep expense.
183
CRMC-003547
Johns-Manville Service to Railroads
Where Used--How Furnished
OHNS-MANVILLE Rag-Pelt Ready Roofings
J are for use on roof decks where the pitch is 1%" or more to the foot.
Made 32" wide and shipped in one-square rolls (108 sq. ft.) or two-square rolls (216 sq. ft.), except Slatekote Brand, which is shipped only in onesquare rolls. Pyramid Kaps or nails and cement, (as ordered), as well as directions for application are packed in each roll.
Regal Brand
The best grade of rag-felt roofing which will give splendid service. Extensively used for barns, sheds, outhouses, garages, freight car roofs, etc. Made in three weights: light, medium and heavy. Approximate shipping weight per square: light 35 lbs.; medium 45 lbs.; heavy 55 lbs.
Slatekote Brand
Made to meet the demand for an inex For use where an: ornamental surfaced,. pensive roof covering. It does not have , inexpensive rag-felt roofing is desired. the strength and durability of Regal Brand Made of a heavy sheet of rag-felt armored but . for the .conditions -under which ; it with a coating of crushed RED, GREEN should be used and ;considering .its cpsti.it . or BLUE BLACK slate, which is securely .will give very satisfactory; service. Made, imbedded into the surface of the felt. Has a in three weights, light, medium and heavy,': ; 2" selvaged edge to permit the proper join` Approximate shipping weight per square:, ing of laps:;: Made in one weight only ; light 35 lbs.; medium 45 lbs./heavy 55 lbs. shipping weight, about 85; lbs. per square.
Pyramid Kaps
The Pyramid Kaps are patented roofing fasteners which are far superior to nails and cement because they assure a more watertight and weathertight job.
They are applied, end to end, along the entire length of all horizontal and vertical laps, thus providing a continuous, evenly distributed pressure at all points where the roofing felts are joined. This avoids the puckering, buckling and tearing away of felts due to imperfect cementing or where
nails are driven into knot holes or cracks and the other faults of application some times experienced where nails and cement are used.
These Kaps are designed for quick and easy application and their efficiency in ser vice eliminates 90% of leaks experienced with ready-to-lay roofings. See page 143 for complete description.
These Kaps are only furnished when or dered, at slight additional cost.
184
CRMC-003548
Johns-Manville Service to Railroads
Johns* Manville Roofing Accessories
Johns-Manville Asbestos Fibrous Enamel
An acid-resisting, bitumi nous coating, made of asbes tos fibre and natural asphalts and oils.
It has the consistency of heavy paint or enamel and is furnished in two colors, black and red. It produces a tena cious, durable, protective film, thus seal ing the metal or roofing from the weather and preventing rust, corrosion and unnec essary upkeep expense.
Due to the use of Asbestos' fibres, it is remarkably elastic, expanding and con tracting with the/surface and avoiding chipping and flaking common to ordinary paints, .assuring longer and;better service.
Used on exposed steel work, bridges, iron electric railway poles, street lampposts, skylights, outside stairways, fireescapes, cornices, agricultural imple ments, contractors' equipment. In fact, every place where metal or composition roofing is exposed to the weather or to other corroding influences it should be covered with Fibrous Enamel.
Easily applied; will not check in dry weather nor crack in cold. Covering ca pacity, 100 to 150 square feet , per gallon, varying according to the surface to which it is applied. Shipped ready for use in containers the same size as shown for Black Regal Roof Coating.
Johns-Ma nvi 11e Regal Roof Coating
; An impervious^ durable, protective coat ing for : roofings /generally -- especially composition felt, tin, iron or other metal. Also for the protection of steel work. Made of pure asphalt and asphaltic oils absolutely free from coal tar pitch. For this reason it retains its waterproof qual ities much longer than other similar pro ducts, making it most economical and satisfactory.
It preserves the life of felt roofing be cause it penetrates the body, fills the voids and restores its original waterproof and weather-proof qualities and what is of es pecial importance, it maintains this con dition indefinitely. On metal roofs, lead
ers, gutters; etc., it fills; fust spots, pin holes, seams, etc/; It is unaffected by con traction or expansion, gases or alkalies. Will not run in hot weather nor crack in cold..
Made in black, light red, and light green. Furnished in 1, 2, 3 and 5 gallon cans, 25 and 50 gallon drums in the Black. Colored coatings are furnished in 1 and 5 gallon cans and in half and full barrels.
Covering capacity 150 to 200 square feet per gallon, varying according to the smoothness and porosity of the surface.
185
CRMC-003549
Johns-Manville Service to Railroads
Johns-Manville Asbestos Slater's Felt
N insulating felt made of asbestos
A fibres, impregnated with natural * asphalts. Used as an insulating
As it contains no vegetable, animal or organic material it is rot and weatherproof and will
and waterproofing material between roloafst indefinitely. Made 32"
boards and shingles, slate, tile, etc.; also wide and shipped in 3-square
between siding and shingles and similar rolls. Weight approximately
building insulating purposes.
14 lbs. per square.
Johns-Manville Asphalt Roofing Cement
For the application of built-up roofing or to re-waterproof and provide a weather proof surface finish for old roofing felts; for the laying of patch strips or full
sheets of felt in general roofing repair work, where conditions demand a mop ping of hot asphalt.
Johns-Manville Asphalt Roofing Ce ment is shipped in full, one-half and onequarter drums, weighing approximately 400, 200 and 100 lbs., respectively. As shipped it is a solid, hard mass which is melted in kettles at the job and applied hot.
Johns-Manville Asbestos Roof Putty
A roofing cement used to stop leaks,'; due to holes in tin, zinc, slate,: shingle, wood or .composition roofs* gutters or; flashings; also for pointing up around leaky chimneys, skylights, etc. ;i iiv fact, may be used for any job where leak-proof.
repair cement is desired. Shipped ready for applica
tion in black, red and gray in 1, 2, 3 and 5 lb. cans, 25, 50,100 and 200 lb. containers.
Johns-Manville Cold Water Paint
(For Interior Use)
Johns:-Mahvi;lle- White Cold Water, ing for all interior building and, other
Paint makes a durable, fire-resisting coat- surfaces; brick, stone, concrete, plaster
or Wood. For the interior of train
sheds, factories, warehouses, garages,
docks, freight houses, interior squash, ten
nis and handball courts, gymnasiums, ho
tels, clubs, hospitals, office buildings,
stables, etc.
Furnished in white and sixteen tints,
which can be intermixed to obtain any
other desired tint, or can be deepened in
tone by adding a small portion of ordinary
After an application of Johns-Manville Cold Water Paint.
tinting colors.
186
CRMC-003550
Johns-Manville Transite
Asbestos Wood
187
CRMC-003551
Johns-Manville Service to Railroads
Fresh Pond Road Station, Brooklyn Rapid Transit System. H. J. Kolb, Engineer of Design, Brooklyn, N. Y.
Johns-Manville Transite Asbestos Wood as interior paneling.
Johns-Manville Transite Asbestos Wood
OHNS-MANVILLE Transite Asbes - Johns-Manville Transite Asbestos
J tos Wood is a (flat) rigid, all-mineral Wood has all the desirable properties of material for general' use in permanent, natural wood arid sheet metal but it is su fireproof interior and exterior construc- perior to them. Unlike natural .wood
; 'tion, in place of natural-wood,;plaster, wall- Transits is not inflammable. It cannot
board,, stucco, or sheet metal. .
burn because it is actually a sheet of stone
Johns - Manville. Transite Asbestos --neither will it rust, dent or buckle like
: Wood is made of asbestos, fibres and Port- sheet metal.-r And .Transite never needs
... land, cement united under , hydraulic-pres paint or any other surface protection
sure into, dense, homogeneous, structur which eliminates the expense and bother
ally strong sheets of various sizes and of maintenance so necessary for natural
thicknesses.
wood and sheet metal.
Easy to Apply
Johns-Manville Transite is easy to ap ply. It is comparatively light in weight and can be handled in the same manner and with practically the same ease as any hard wood. It can be cut and worked with ordinary tools and fastened with nails, screws or bolts.
It is unaffected by water, alkali and most acids. Sudden or extreme changes
of temperature do not affect it in any way; it actually becomes tougher with age.
It has many of the physical character istics of ordinary wood, except that it is harder and takes a higher polish.
It has a fibre strength under transverse loads of 3,500 pounds per sq. in., being about two-thirds as strong as ordinary wood.
188
CRMC-003552
Johns-Manville Service to Railroads
Attractive Appearance
Transite has a neat, attractive appear ance. Its smooth, gray surface permits its use just as it comes from the factory but where it is necessary to have Transite match the surroundings it can be painted, varnished or grained as desired.
In every way Transite Asbestos Wood is the ideal material for walls, partitions, panelings, ceilings, fire doors, roofing or siding, because it provides the maximum of fire protection and durability with the
minimum of construction thickness. Johns - Manville Transite Asbestos
Wood is approved by Underwriters' Lab
oratories, Inc. Its fireproof nature, its durability, its
service economy and many other desirable qualities recommend it strongly to archi tects and engineers for use in railway sta tions, public buildings, shops, garages and factories for many of the purposes sug gested in the list below.
How Furnished
Transite Asbestos Wood is made in two finishes -- STANDARD and SPECIAL, Standard Transite is reasonably smooth on both sides. Special Transite is perfectly smooth on both sides and is preferable for use where precise and uniform thickness throughout is desired. Both kinds are furnished in sheets 36" x 48", 42" x 48" and 42" x 96" in the thicknesses shown below,
The finish of the- %" thickness is slightly
different--it is reasonably smooth on one side and slightly pebbled on the other and is oniy furnished in the 42" x 96" sheet when specially ordered,
_ Where it may be desired to use a flat instead Of a corrugated material, Special Lipped Transite is .recommended. Details of application of this material will be
found on page 191.
Thickness: : ..., . .} s"
Approximate. Weight per Sq. ft. lbs., 1 '1.7
W.. : H" '
: -2-1 - . 2.? > 3.4
i.
h" - . .1"
. Hi". '
2.' . -
4.0 . 5.3 . 7.6.. 10.1
13.0; . 15;. 7 ; 18.5 , , 21.0 ..
A Partial List of Uses in Prominent Industries
Automobile Manufacturers
Acid ducts and openings Automobile foot boards . Baffles Ceilings, walls, partitions, sid
ings: walking surface over enameling ovens: over rail road switching tracks in ware houses Dry kilns Furnace dampers and doors Smoke flues and breeching lin ing Ventilators
Chemical Industry
Acid ducts and openings Bus-bar barriers and spacers Ceilings, walls and partitions Cabinets, boxes and . similar
equipment in laboratories, etc. Fume Hoods General Fireproofing Furnace dampers and doors Smoke flues and breeching lining
Table; sink tops and hoods Ventilators
Manufacturing General
Drying .and enameling ovens Baffles--Over oil stills; in stor
age battery dry olate kilns; between Burton stills Ceilings, walls and partitions Canopies over loading platforms Cabinets: boxes and similar equipment Dry Kiln Partitions Fire doors General Fireproofing Fireproof Partitions--Office and Industrial buildings Furnace dampers and doors Fireproofing Elevator shafts Powder Houses Smoke flues and breeching lining Storage Bins Siding and roofing Oil and Gasoline Storage Rooms Ventilators
Oil Refineries
Ceilings, walls and partitions Curtain walls between condens
ers in refineries Cabinets, boxes and similar
equipment Dampers General Fireproofing Furnace and Flue dampers and
doors Fire Barriers Housing for Insulated Pipe
Lines Ventilators
Railroads
Ceilings, walls and partitions Canopies over stations and load
ing platforms General Fireproofing Under upholstering of car seats
where heating coils are in stalled Portable houses
Smoke jacks Ventilators Smoke Ducts
Rubber and Rubber Goods Manufacturers
Ceilings, walls, partitions Curing rooms General Fireproofing Furnace dampers and doors Laboratory Table tops Ventilators
Textile Industry-
Acid ducts and openings Bins for storage of hemp, saw
dust or textiles Ceilings, walls and partitions Fire doors General Fireproofing Smoke flues and breeching
lining Table tops Ventilalors
189
CRMC-003553
Johns-Manville Service to Railroads
Some typical uses of Transite As bestos Wood un der widely dif ferent conditions. Top right and left: As used for oil switch com partments. Left center: As in terior sidewalls.
Center: On walls and ceilings of railroad main dining room. Right Center: On walls and ceiling of underground passageway. Bot tom: As exterior siding.
190
CRMC-003554
Johns-Manville Service to Railroads
el
Figure'1. Sketch' of -Transite Asbestos Wood Roofing showing specialJip.' construction.
Figure 2. Details of ridges, lining of gutters and valleys, etc., in connection with the application of Transite Asbestos Wood Roofing, special lip construction. 191
CRMC-003555
Johns-Manville Service to Railroads
ASB.T&DU Panel / Voo> EVRJLUfG
ASB.WC3D> BaTTEH'
ELEVATION OP JIJ>riVAU_-
E)XOCK.IK<JWodJ> RAIL.
SheaTHIhg-
LOTTGm/JMAL
Stvwihg
ASh ya . K-AS5- WCDJ
.) .
PAttLU_
Note- *
A3Bt5T05 VC5*r>. SIZE*
SH-tlPTS ARfr
Asb . Wqd> Yaiv?i. .
TAIL
4E"x4-e" A1^J> 3G"*Ae"
Casb.Vgdj* mat also xr
5tCT10H
XrSX-> TOR. ^XTE-5J05l
flCDR
CtILl'KG VIE-w
PAht-LS Alf> HALF IIKbPRJ ET-KfcCTS0 '
Figure. 3. Application.'of Standard Transite* Asbestos Wood as. wall panels with/'batten strips.
Figure 4. Application of Standard Transite Asbestos Wood as a paneling for ceilings.
192
CRMC-003556
Johns"Manville Service to Railroads
Johns -Manville Transite Asbestos Wood Smoke Jacks
OHNS-MANVILLE Transite Asbestos usual conditions, special designs will be
J Wood Smoke Jacks, being made of an all-mineral material--Asbestos Wood
furnished. The ventilated type of jack is to be pre
--will withstand gas, sparks, frost andferred as this type will permit the escape
moisture far better than wood or metal through the ventilating space of any
jacks. Both wood and metal jacks require smoke or gases which may, due to impro
frequent painting; in the case of wood per spotting of the locomotive, fail to be
jacks, to make them somewhat fire resist drawn out through the stack.
ant, and also to slow up the inevitable and
The lightweight of these jacks, coupled
rapid decay. The metal jacks must be with their simplicity of design, makes
heavily blanketed with paint to guard them easily assembled and erected, and
against the destructive forces of the ele avoids the necessity of special roof sup
ments outside of the roundhouse and the ports.
gases pouring from the stacks of the loco
The various standard jacks are illus
motives inside the; houses vjbhhs-Manville trated on the followingTages.,'
' Transite Asbestos Wood .Smoke jacks re-,
quire nb painting; hr. 6ther upkeep,\ Their
first cost is their fifial tbst.h.AJA
We have deyeloped^tbis line-to a point
where we can ship anw{dbsiredrnumbeAbf
;hur ten;standar.d-;jaqks\with.';:prat^
delay, and when; necessary to, meet un
Johns - Manville Transite Asbestos Wood Smoke Jacks and Johns-Manville Asbestos Built-Up Roofing on round house of Central Railroad of
New Jersey, Communipaw, N. J.
193
CRMC-003557
Johns-Manville Service to Railroads
Johns -Manville
Transite Asbestos Wood Smoke Jack, Type "G
(Patented)
The type "G" Smoke Jack illustrated here, is a low priced and popular style of Jack which has been in use on various railroad systems under all conditions of service for a number of years. It is light in weight, easily installed and requires prac tically no attention after being erected.
The illustration and bill of material
e0W*,
U
to*i Cast A*ft*
\
Co*tr,hepds fa?
. jcr&r* Witn
cover types "G-l" and "G-2." For type "G-3," which has a 10-foot stack, an extra 2-foot stack section and collar are fur nished.
BILL OF MATERIAL
Part
Description
Quantity Per Jack
fyp e G -No. 2 G -No- 1
A Transite Cap, with
reinforcement .... 1
B Transite Stack
Piece ......................... 2
C Transit e Stack
Piece ........................ 2
F Cast Iron Flashing
i
2 2
Angie (4 pieces) G Cast Iron Collar (4
pieces) .................... H Transite Hood Piece J Transite Hood Piece K Transite Hood Piece L Transite Hood Strip M Transite Hood Strip
1 1
2 2 2 2 2
1
1 2 2 2 2 2-
P Hanger .Irons, ,^"x .2"x5'-6" or to'suit 4
4'
R, ..Iron : Cap - Supports, 4
4
.. S../ Plain ..Lag- ; Screws/. 32' V 32
Plain Machine .Bolts,' . .' .%.','x2''; (-1- washer) .16 Vy -Round ,' Head '; Iron .--.yStoveBolts, .-%"x
- ' 1.5 - ..
.... 130 . . 130 A
W ..Round. Head ; Iron
\ASt.ove; -.-Bolts,' %"-x
vv-;i2^.=-'-;:-;V-L iVA-Av//-.- 142 : 110
i
xr . Disked Washers: for.
Bolts .
..: 544 480 '
Cement -. .
50 lbs. 40 lbs.
Galvanic Varnish.... }A gab Vz gal..
Opening in roof sheath ing should be :n accord ance with the following dimensions:
r i
NOTE:--When ordering pa'rts: state part numbers as shown.
All identification marks plainly stamped as shown.
IMPORTANT:--Protect body and threads of bolts and cover ail bolt heads and nuts with cement.
Paint cap supports, hanger irons, iron hood to stack collar and flashing angle with two coats of Galvanic Varnish.
Opening in roof timbers should be 28"x51".
Line No.
1 2 3
No. Type
G-l G-2 G-3
A
4'0" 8'Q" lO'O"
Weight (in place)
1265 lbs. 1445 lbs. 1605 lbs.
194
CRMC-003558
Johns-Maiwille Service to Railroads
Johns-Manville
Transite Asbestos Wood Smoke Jack, Type "H"
(Patented)
The type "H" Smoke Jack is similar to type "G,'? with the addition of a roof stack, which makes it a ventilating type. This ventilating feature provides for the escape from the round house of smoke or gases which may, due to improper spotting of a locomotive, escape from the hood. This Jack is installed in the same manner as the type "G," requiring no special bracing of the roof timbers.
Quantity
Part
Description
Per Jack
A Transite Cap with reinforcement i B Transite outside stack piece......... 2 C Transite outside stack piece......... 2
D Transite outside stack strip......... 2
E Transite outside stack strip......... 2
F Iron stack feet, 3^"xli4"x6"xl8" 6
G Cast iron collar (4 pieces).............. 1
H Transite Hood Corner Piece......... J Transite Hood Corner Piece......... K Transite Hood Side Piece.............
2 2 2
L Transite Hood Strip........................... 2
M Transite Hood Strip........................... 2
N Transite Inside Stack Piece........... 2
O Transite Inside Stack Piece........... 2
P Iron Hangers, *4"x2"x5'-6" or to
suit ........................................................... 4
R Iron Cap Supports, 34"xl5-T'x7J4"
x33"
.................................................. 4
S Plain Lag Screws,54"x254" ... 28
T Plain Machine Bolts, A4"x2"
(1 washer).........;..................
16
V Round Head Stove Bolts, y^"x\y2"
(iron)-
A .;........ 284
W Round Head -Stove: Bolts, :$"x2"
(Iro.n) _____ ... ..... . ............
42
'X Dished Washers for.- 44" Bolts.: 652
Cement
. 1. / 50 lbs. .
Galvanic' -Varhish .4. .... .... 54.gak.
> Bex bt/rii vp (e> to svppe't arts.*
staot
Cere* fttoss ef 'ey,
--------
Weight in place--1615;lbs.'
''
NOTE:--When ordering- parts Estate, part- num bers as shown.;y '' 'V
All identification, ma'rks.'pjaiiily..stamped as shown.
IMPORTANT (-^Protect.body and threads ofbolts and cover alb bolt .heads and nuts with ce ment.
Paint cap supports, hanger irons, iron hood to stack collar and flashing angle with two coats Galvanic Varnish. , /
Opening in roof' timbers should be 28"x51".
Opening in roof sheathing and box should be in accordance With the cut below:
Sectie*
to -c
195
SecTion ot foot Line.
CRMC-003559
Johns-Manville Service to Railroads
Johns-Manville
Transite Asbestos Wood Smoke Jack, Type "J"
(Patented)
The latest developments in Smoke Jack design have been included in the type "J" Smoke Jack. It has been built to meet the requirements imposed by the large loco motives now in service. The hood is de signed with an angle which will mater ially assist in disposing of the greatest amount of smoke consistent with the
stack dimension. The round stack pro
vides for the greatest possible smoke
space, with the minimum opening in the
roof.
The illustration covers types "J-l" and
"J-2." For
which has a 10-foot
stack, an extra 2-foot stack section and
collar are furnished.
BILL OP MATERIAL
Quantity Per Jack
Part -- A AB AC B BC
C G H HA
J JA K. KA KB KC b:
~. Description
Type J-No. 1 J-No. 2 J-No. 3
Cap m 2 pieces, with cleat.............. I Stack Section...........................................
I1 1
Stack Cleat................................................
1
Stack Cleat..-.......... .............................. Stack Section........................................... 1
11 1
Stack Cleat. ..................... .. -.................
11
1
Cast Iron Hood to Stack Collar.. 1
1
Hood Corrier Section (Transite)., 2
22
Hood Corner .Section (Transite).. . 2 . Hood Corner Sectiori (Transite)..' 2
2 2
2 2
Hood Corner Section (Transite).. 2
22
Hood Side. Section (Transite) 2 2 .2
Hood Side Section (Transite)-... 2
2 .2
Hood Side. Section (Traiisite).... 2 2 2
Hood Side Section (-Transited... 2
22
Hood Side;, Cleat. (Transite) v.-.1 (;
2 " 2 '
M MAP T --*
--
Hood End 1 Cleat '(Transite) .;. 2 .
Hood End ' Cleat- (Transite):.;.... 2 Ho.od Side Cleat .i.Tratvsite),;l .: 2
Hood Side , Cleat (Transite); . ... ?, Flashing Angle, (Casr .Tron) :3' pcs. 1
Round Head"- Iron ' Stove '. Bolts. (1Vi" x f(i'(.:-.....V..Av..T.-..: 339 '
;2 2
' '2: 2 1
384:
2 2 2, '' 2 1
428
---- . Round Hedd-, Iron'.. Stove: Bolts.
2": X
.............
72 '
'72- ' 72 '
Lag Screws, 2" x.
...:... 28
28 26
--- . Machine Bolts; 2" x A"............. 16 16 16
Dished Washers....... .. ---- Cement
S22 912 1020 . 60 lbs. 70 lbs 75 lbs.
' -- Galvanic Varnish'. ... i ... i.
A ga:
Iron Cap Supports, Ya" x 1!4" x
7YY` x 33"................... ........... ........... 6 6 G
Hanger Irons, U" x 2" x 9'-6".. 4 4 4
NOTE:---When ordering- parts state part letters as shown. All identification marks plainly stamped as indicated.
IMPORTANTProtect body and threads o{ bolts and cover all bolt heads and nuts with cement.
Paint cap supports, hanger irons, flashing angle and cast iron hood to stack collar with two coats Galvanic Varnish.
Opening in roof timbers to be 46"x4G".
Opening in rool sheathing should be 41" in diameter.
Line No.
Type No.
1............................... J--No. 1
2............................... J--No. 2
3............................... J--No. 3
196
A
4'-0" 8'-0" lO'-O"
Weight (inplace)
2060lbs. 2315lbs.
2570 lbs.
CRMC-003560
Johns-MaimUe Service to Railroads
Johns-Manville
Transite Asbestos Wood Smoke Jack, Type "K"
(Patented)
The type "K" Smoke Jack is identical
with the type "J" Jack, with the exception that it has a roof stack--thus providing a ventilating feature. There are occasions when a locomotive is improperly spotted and the smoke escapes from the hood. With this type of Jack such smoke is drawn out through the space provided between the inside and the outside stack.
BILL OF MATERIAL
Part --
Description
Quantity Type
K-No. 1 K-No. 2
Cap in 2 pieces, with cleat--
(Transite) .................................... 1
1
A Stack Section, Inside (Transite) 1
1
AB Stack Cleat, Inside (Transite) AC Stack Cleat, Inside (Transite)
1 1
1 1
B Stack Section, Inside (Transite) 1
1
BC Stack Cleat, Inside (Transite) 1 C Stack Section, Inside (Transite) 1
1 1
G Cast Iron Hood to Stack Collar (4 pieces).............................. 1
1
H HA
J JA K
Hood Corner Section (Transite) Hood Corner Section (Transite) Hood Corner Section (Transite) Hood Corner Section (Transite) Hood Side Section (Transite)
2 2
2 2 2
2 2
2 2 2
KA Hood Side Section (Transite) 2
2
KB Hood Side Section (Transite) 2
2
KC Hood Side Section (Transite) 2
2
L Hood Side Cleat (Transite).. 2
2
M Hood End Cleat (Transite).. 2
2
MA Hood End Cleat (Transite).. 2
2
P Hood Side Cleat (Transite).. 2
2
T Hood Side Cleat. (Transite) .. 2
2
W Stack Section, Outside (Tran-
site) ......................:.........
11
wx Stack Cleat, Outside (Transite) 1
1
wz Stack Cleat, Outside (Transite) 1
1
X Stack Section, Outside. (Tran-
site)' ............. .(/'.;.. ...
11
XY Stack Cleat, Outside (Transite) 1
1
Y Stack Section, Outside (Tran-
site) ............. -\;;...
1. 1
YZ Stack Cleat, Outside -(Tran-
site)................ A ; iv. ...
1 1 ..
Z Stack Section, : Outside . (Tran-
. site) ......... ..................................... 1
1
-- Flashing Angle (Cast' Iron) 3
pieces '............ .
:,..
__ Round Head Iron Stove Bolts,
1
1
WxM"
......... 394
__ , Round Head Iron Stove Bolts,
468
2"*H" ........... ................................. 56
56
__ Lag Screws, 2"x*.<" .......... 32
32.
-- Machine Bolts, 2"x54" ......... . 16
16
__ Dished Washers ........................... 904 1048
__ Cement ............................... ............... 75 lbs. 85 lbs.
-- Galvanic Varnish ......................... Vz gal. V, gal.
-- Iron Cap Supports, Wxl!/>"x
66
-- Hanger Irons, J^"x2"x9'-6"... 4
4
NOTE:---When ordering parts state part letters a shown. All
identification marks plainly stamped as indicated
IMPORTANT:--Protect body and threads of DoltS and cover at
bolt heads and nuts with cement.
Paint cap supports. hanger irons, flashing angle and cast iron hooc
to stack collar with two coats Galvanic Varnish Opening in rool
timbers to be 4G"x4G". Opening in roof sheathing should be 41' in diameter.
Line
No. l.. ...........................
2. . ...........................
Type No.
K-No. 1
K-No. 2
A
4'-0"
8'-0"
Weight din iilncel
2295 lbs. 2620 lbs.
197
CRMC-003561
Johns-Manville Service to Railroads
Johns -Manville Transite Asbestos Wood Smoke Jack, Type "L"
(Patented)
The type "L" Jack is of the same gen eral design as type "J," but has a shorter and lower hood, so that it can be used in engine houses having too low a roof line to permit the use of the type "J."
BILL OF MATERIAL
1I Part
!--
Description
Quantity Per Jack
Cap in 2 pieces, with Cleat.... 1
|A
B IC
Stack Corner ......................................
Stack Corner ...................................... Stack Corner ......................................
1
1 1
j AB Stack Cleat ..........................................
BC Stack Cleat .......................................... ' CA Stack Cleat ..........................................
1
1 1
G H J IK
Hood to Stack Collar (4 pieces) Hood Corner ...................................... Hood Corner ...................................... Hood Sides .........................................
1 2 2 2
KA Hood Sides ......................................... 2
L Hood Cleat .......................................... I M Hood Cleat ..........................................
2 2
T Hood Cleat ......................................... 2 ' -- C. I. Flashing (3 pieces) ............. 1
i -- Hanger Irons, *4"x2"x6'................ -- Cap Supports, 34"xl'.j".................
4 6
-- R. H, Stove Bolts, M'xl}4".... 252 -- R. H. Stove Bolts, $4"x2"........... 62
-- -.Dished Washers, Y&'...................... 648 :
-- Machine. .Bolts, y2"x2".................. 16 .
-- Lag Screws,. 1<"x2.K"................ 28
-- Cement
.......... .................. 50lbs
-- Galvanic Varnish
...:........... lA gal.
Weight in place--1-775 lbs.
NOTE:--When ordering parts state part letters as shown. All identification marks plainly stamped . as shown. When more than one jack is furnished, parts will be numbered in addition to usual letter ing; via.--1 A, 1 K, etc. All parts bearing same number must be used on same jack.
IMPORTANT:--Protect body and threads of bolts and cover all bolt heads and nuts with ce ment. Paint cap supports, hanger irons and flash ing angle with two coats Galvanic Varnish. Open ing in roof timbers should be 46"x46". Opening in roof sheathing should be in accordance with the cut shown below:
198
CRMC-003562
Johns--Manville Sendee to Railroads
Johns-Manville Transite Asbestos Wood Stacks and Caps
Johns-Manville Transite Asbestos Wood Ventilators
Painting-, and similar forms of. maintenance are unnecessary with-these ,two products. . ;Being--made of Transite Asbestos Wood their all-mineral com position defies weather and acid fumes. They never need painting and actually grow -tougher with age which is the exact reverse of experience
with wood or iron products.
OHNS-MANVILLE Transite Asbestos
OHNS-MANVILLE Transite Asbestos
J JWood Stacks and Caps,are made in all sizes and for all purposes^ The mater ials used in the construction of these stacks,
Wood Ventilators are adaptable wher ever the common wood, iron and cop per ventilators are installed. They are es
is the same as for Transite Asbestos^Wood pecially recommended for engine houses,
Smoke Jacks described in detail on pages gas and power houses, laboratories, fac
193 to 198.
tories, etc., where it is essential to select
They are used principally over forges in a material that will withstand the action
machine shops, on gas houses and chemi of acid and alkaline fumes and gases.
cal laboratories, or as flues for conducting
These ventilators are constructed of the
acid and alkaline gases, as they are quite same material as Johns-Manville Transite
impervious to such destructive agencies.
Smoke Jacks, described on page 193, that
We are in a position to quote on Johns- is, a composition of Asbestos Fibre and
Manville Transite material made to any Portland Cement--recognized as the most
special shape for stacks, flues, hoods or durable and time-resisting materials used
ducts.
in engineering. Prices upon application.
Prices upon application.
See next page for dimensions, etc.
199
CRMC-003563
Johns-Manville Service to Railroads
Johns-Manville Transite Asbestos Wood Ventilators
(Continued)
DESCRIPTION
- The following tabulation describes those, parts of ' "/..' the. .ventilators illustrated above which are marked .;'-.
with similar letter references:
M..Johns-Manville Transite Asbestos WoodStack
N . .......... .. .. .Johns-Manville Transite Asbestos Wood Guard
. P.. ..,.... Johns-Manville Transite Asbestos Wood- Upper Cone
R.....Johns-Manville Transite Asbestos Wood" Lower' Cone
:S ......... ..........Angle Iron Ventilator Support
T.. ................
.Bar Iron Cap Support
U....... ...................... . .Bolt and Separator Cap Support".
W..................................Round Head Stove Bolt
X......................... . . . Lag Screw
Type "D" No.
1 2 3 4 5
Type "E" No.
11 12 13 14 15
TABLE OF DIMENSIONS IN INCHES
ab
cd
ef
g
10 20 17 14 7 1 51;
18 36 31 21
10V2 iK 7
24 49 42 30
14
2
9
30;::
61
54 42
14
5
9
36 74 64 48 21
3 14
Outside diameter of stack.
h 2T 4 3K 5 5 7
j 3 5 6 8 10
k
K K K K K
200
CRMC-003564
Johns -Manville Keystone Hair Insulator
201
CRMC-003565
Johns-Manville Service to Railroads
Johns -Manville Keystone Hair Insulator
A Necessity in Qood Building Construction
HE increasing value of floor space
Tin all types of buildings demands that walls, floors, partitions, etc., be of minimum thickness. One of the evils and discomforts which come with such space conservation is the annoyance due to the great increase in the noises transmitted through such parts of the building. Also the loss of comfortably cool rooms in summer and increased coal con sumption required to properly heat such rooms during the win ter months. All this is due directly t o the
reduces to the minimum the disturbing sounds generally transmitted through thin, hard walls, floors, ceilings, etc., but which also provides an efficient barrier to heat and cold.
Johns-Manville Keystone Hair Insula tor efficiently meets this three-fold re quirement, not only adds to the privacy
but greatly increases
the comfort of the ten ant or owner. It nets a
cumulative return on the investment by the
yearly savings in fuel
required to properly heat the structure.
practically negligible ; heat, cold and sound
resistance of such con struction and the ma-. terials used. . These objections can
illustration shows typical struc-
While Keystone Hair Insulator is particular ly adapted for heat and cold and sound insulation in private dwell-
be easily overcome by .
Hair insulator.
mgs, hospitals, dormi-
the adoption of a sirn- ;
: y. jtories, etc., it will be
pie yet effective remedy--building insula- . apparent that practically - every type of
tion with johns-Manville Keystone Hair . building can be made more comfortable in
Insulator. Progressive, architects: arid summer and still more comfortable and
. owners have always insisted upon build- -easier to heat in winter if it is protected
. ing insulation---insulation which not only with Keystone.
Building Insulation
An Investment in Comfort and Economy
Efficient wall, floor, ceiling and roof insulation is an investment--not an ex penditure. It pays dividends every year it is in service in the added comfort and greater operating economy it af fords. . But what is proper and efficient insula tion? How can owner, engineer or archi
tect differentiate between the good and bad in the various kinds of insulation that are offered? Clearly, the best insulation must answer certain definite requirements and because Keystone measures up squarely to the conditions for which it is recommended we offer it as the best insu lation and stand ready to prove our claims.
202
CRMC-003566
lilaiyiisit Johns-Manville Service to Railroads
Why Johns-Manville Keystone Hair Insulator Is Superior
O meet the exacting demands of the majority of the average "insulations"
Tmodern construction practice a build can be quickly rejected. They are un ing insulation must be sanitary, fire- clean, furnish refuge for vermin, are high
resisting and durable or it is a menalyceinflammable, rot, "pack down" or have
to health, to safety and
little or no insulating
to your investment.
value because they are
It must be durable
too tightly packed or
because deterioration
are not adaptable as
and the necessity for replacement in a few years not only mean annoyance and expense but such work is prac tically impossible after the building has been completed and occu
good insulation.
Johns-Manville Key stone Hair Insulator because of its construc tion and the materials of which it is made has none of these draw
pied.
backs, yet it possesses
And what is more important--it must be v.as11 y more. than. a
Franklin High School, Seattle,. Wash., Edgar Blair,- . Architect. Johns-ManvilleKeystone'Hair Insulator is used for .prac-.
tically/cvery type of building.
all the virtues claimed for the ordinary insu lations. Not only that
mere "filling." It must
but the user can get
insulate~effectively by offering the maxi just the proper insulation for his con
mum resistance to heat,- cold, dampness ditions. The insulating material used in
and sound.
d:. Keystone^chemically cleansed cattle hair
And it certainly ought not to be readily --is furnished with plain building paper,
inflammable or carry . flame.
asphalt saturated or. asbestos paper on
How many insulations meet .such rigid one or both sides according to the re
requirements? ; Investigation shows that quirements.
Actual Savings in Coal by the Use of Johns-Manville Keystone Hair Insulator
The illustrations on page 207 show typi cal methods of outside wall construction with Johns-Manville Keystone Hair Insu lator installed as a heat and cold insula tion, in comparison with the same forms of construction without insulation.
No. 1 shows wall without insulation.
Nos. 2 and 8 show application of one layer of Johns-Manville Keystone. No. 9 shows the application of two layers of Keystone.
As an example of the efficiency of Key stone Hair Insulator, the rate of heat transmission through No. 2 is only .182
203
CRMC-003567
Johns-Manville Service to Railroads
B.t.u. per square foot
No. 1 under the same
of exposed wall surface
conditions. Therefore,
per hour, per degree
there is less than half
temperature difference
of the heat loss through
between air inside the
a wall insulated with
building and air out
two layers of Johns-
side, while the loss
Manville Keystone
through the same con
Hair Insulator as
struction (No. 1), with
shown in No. 9 than
out Johns-Manville
through an uninsulated
Keystone, is .28 B.t.u.
wall, as shown in No. 1.
under the same condi tions.
Translating these figures into pounds of coal saved by the use of
Residence of N. Roy Shambleau, South Bend, Ind. which was insulated with Keystone.
Johns-Manville Keystone Hair Insulator is ideal for the moderate size residence.
With No. 9 the ac tual saving in coal is 348 pounds for every 100 sq. feet of exposed sidewalls during a heat
Keystone Hair Insulator in outside walls, ing season of 210 days, with an average
shows an actual saving of 236 pounds of temperature difference of 40 F.
coal for every 100 sq. feet of exposed side- The net results to the user of Johns-
walls during a heating season of 210 days, Manville Keystone Hair Insulator are
with an average temperature difference of such a saving in coal consumption as
40 F;
should pay for the material in a short
The rate of heat transmission through. time; maintenance of more even tempera-
No. 9 is only .135 B.t.u. per sq. foot per tures in his building; cooler in summer,
deg. temp.: difference per hour, as com- warmer in winter and more comfortable
pared with the loss of .28 B.t.u. through and quiet at all times.
Description of Keystone Hair Insulator
Johns-Manville Keystone Hair Insula-.: in weight than most other insulating ma
tor consists of a heavy layer of thoroughly cleansed cattle hair securely fastened be tween two sheets of protective paper, es pecially chosen for the conditions under which the insulator is to be used, as will be noted under the full description of brands, on page 205.
The body of Keystone is the best grade of cattle hair, treated chemically to render it vermin-proof and odorless. It will not dry out, split, pack down or rot with age and lasts indefinitely. As it merely shriv
terials and therefore easier to handle. It is uniform in thickness throughout and be ing flexible, fits odd corners making it easy to apply.
Packed in bales 3 feet wide containing five hundred square feet with the edges bound and beveled. It spreads on surfaces as easily as paper or wool felt and is, therefore, easily applied. The bound and beveled edges allow a 1" lap instead of hav ing to be butted, thus assuring tighter and
els when it comes in contact with fire, it more effective application. Excello Brand,
will not carry flame.
page 206--furnished in sheets 3' x 8'.
Bulk for bulk Keystone is much lighter All weights given are approximate only.
204
CRMC-003568
Johns-Manville Service to Railroads
Where Used for Insulation or Sound Deadening
Johns-Manville Keystone Hair Insu lator is recommended for the following uses but this is by no means a comprehen sive list as Keystone serves in almost every place where an efficient, durable material is desired for heat and cold insulation and sound deadening.
Sound Deadening: Passenger sta tions, offices, residences, Y.M.C.A.'s, apart ment buildings, schools, hospitals, studios,
hotels, dance halls, theatres, lodge rooms, dormitories, bowling alleys, etc.
Insulation: Refrigerator cars, ice boxes, cold storage and refrigerating plants; all types of apartment houses and dwellings, factory or other roofs, poultry houses, garages, dairies, etc.
Detail drawings on page 208 show some typical methods of installation.
The Various Brands of Johns-Manville Keystone Hair Insulator
Salamander--^Fireproof and damp- Neptune--Waterproof paper on one
Asbestos paper on both ..sides. side and plain gray building paper on the
.For. fire protection,as well as insulation other. For. use where protection against
,again.st heat and cold.
dampness is desired.
Also for sound deaden
Packed in bales of 500
ing. Packed in bales of
sq. fU, weighing 75 lbs.
500 sq. ft., weighing
----36" wide.
130 lbs.--36" wide.
Double : Neptune --
Phoenix---Fireproof and damp-*proof Asbes tos paper on one side, and plain gray building paper on the other. Packed in bales of 500 sq. ft., weighing 100 lbs.--36" wide.
Res. of J. C. Oliver, Sewickley, Pa. JohnsManville Keystone Hair Insulator makes
every building more comfortable.
Waterproof paper on both sides. For weather proofing against ex cessive dampness. Also for sound deadening. The best brand for this purpose. Packed in bales of 250 sq. ft., weighing 42% lbs.--36"
Peerless--Wool felt
wide.
paper on one side and plain gray build
Acme --Plain gray building paper
ing paper on the other. Particularly on both sides. Can be used for all
adapted for sound deadening where fur forms of general insulation and weather
ring strips are not to be used. Packed in proofing. Packed in bales 18" or 36"
bales of 500 sq. ft., weighing 85 lbs.--36" wide, containing 500 sq. ft. and weighing
wide.
65 lbs.
205
CRMC-003569
Johns-Manville Service to Railroads
Empire --The same as Acme Brand except that it has a thicker felting of hair and weighs more. Packed in bales of 500 sq. ft., weighing 80 lbs.
Arctic--Arctic brand is especially adapted for cold-storage work. Covered both sides with heavy asphalt-saturated paper; water and vermin-proof. It is also used for insulation between walls in music rooms, such as phonograph rooms in de partment stores where transmission of sound is annoying. Packed in bales 3 ft. wide, containing 150 sq. ft., *4" thick, weighing 65 lbs. per bale, and %" thick, weighing 85 lbs. per bale.
Excello--This is a rigid insulation with chipboard backing. It meets most satisfactorily the demand for panel insu
lation in the erection of houses, garages, bungalows and other detached buildings. Furnished in sheets 3x8 feet and packed 21 pieces to the bundle, approximately 500 square feet. Packed for shipment a bundle will weigh from 165 to 170 lbs.
Excello can also be furnished in panels 18" wide by 8 feet long, when so specially ordered.
In many instances, the insulation will be used on the inside face of the studding. However, where studs are only 16" from inside to inside and it is desired to use the insulation between studs, the narrow 18" panel of Excello can be forced into place, bending it V on either side. This will not detract from the insulating value of the material and will not be considered objec tionable by contractors.
Science Hail, a new building for Marshall College, Huntington, West Va., insulated with Johns-Manville Keystone Hair Insulator, Keystone makes every building warmer in winter, cooler in summer and quieter all the time.
206
CRMC-003570
Johns-Manville Service to Railroads
Diagrammatic Drawings of Typical Wall Constructions for Johns-Manville Keystone Hair Insulator
CRMC-003571
Johns-Manville Service to Railroads
Details of Jokns'Manville Keystone Hair Insulator
TYPES OF WALL AND PARTITION INSULATION
TYPES OF FLOOR AND CEILING INSULATION
SECTIONS THRO PAPT/TJOA/5 OyPSl/At 0/OCffS O/l HOILOH' T/IE
KEYSTONEHAIR INSULATOR IN SUSPENDED CEILING KEYSTONE HAIR. INSULATOR UNDER ROOF
KEYSTONE HAJ& INSULATOR UNDER FLOORS (rough andfinishedflooring foe-nailed ofedges)
CRMC-003572
J ohns-Manville Industrial Flooring
209
CRMC-003573
Johns-Manville Service to Railroads
Johns -Manville Industrial Flooring
FLOORING that is a solid mono
A lithic sheet of mineral without con struction joints or cracks; that can
trucks, the hard knocks of massive castings or the comparatively light weight of foot traffic--and recommend a proper con
be laid in just the right consistency and sistency and thickness of Johns-Manville
thickness to meet the service conditions Industrial Flooring that will assure the
under which it is to be used. A flooring that is resilient; slip-proof;
easy under foot; dry and warm; fire re tardant; alkali and acid resistant.
These are the features that make JohnsManville Industrial Flooring supreme in its field--that free it from the shortcom ings of other flooring which cannot be changed to accommodate the varying de mands Of different services. JohnS-Manville-Industrial Flooring is a combination of the best materials and the long experi ence of our engineers.
greatest satisfaction. We know before any of the material leaves our factor}'what the floor must do and the recommendation of our engineer is rigidly followed by expert workmen whose skill is the result of constant application of our flooring in every part of the United States and Can ada. So, the flooring, from the first meas urement to the final finishing stroke on the top coat, is in the hands of conscientious experts--every precaution is taken and the responsibility for your satisfaction is con centrated in the Johns-Manville organiza-
Its remarkable success is due:
tion.
1. 'To the natural .durability of-the ma-.
teriais of which it is made.
Johns - Manville Industrial Flooring
/ 2. To it's "flexibility^ i which 'permits consists of a binder or asphalt cement
fitting it exactly to service requirements, made up of a combination of natural as-
an3_L
; ; phalts and a well graded mineral aggre-
3. To the fact that we Control every 'gate ranging in size from that passing a
element in its man
%" screen down to
ufacture and appli
that which passes a
cation and can maintain a uniform ly high standard.
There is no hit or miss about JohnsManville Industrial Flooring. Our en gineers carefully study your present
200 mesh screen. The finer aggre
gate, or that passing an 80 mesh screen, is combined with the asphalt cement by heating and me chanical agitation at our factory for a
or prospective ser
period of several
vice conditions --
hours. The mass
whether the grind ing wear of heavy
The extremely severe service conditions of the Canadian Pacific Railway Shop has proven the superiority of Johns-Manville Industrial Flooring.
is then molded in to blocks of con-
210
CRMC-003574
Johns-Manville Service to Railroads
venient size for shipment. These blocks are of 1*4" weighs only 18 lbs. to the square
broken up on the work and reheated to a foot in place.
temperature of 450 F., mixed with the coarser aggregate, using a pure asphaltic
Easy and Economical to Repair
flux to help break down the blocks in the This flooring is not only easily laid but
kettle, giving proper consistency in the easily repaired if changes in the floor
floor.
surface are made necessary at any time or
The resilient, softened and plastic mass where unusual hard service or accident re
is transported to the work in oak buckets, quires an occasional patch. In fact it is the
laid down hot in one and two courses, de only monolithic flooring which is so easy
pending upon the re
to repair. Just cut out
quired thickness and then given a compara tively smooth finish by rubbing with wood floats.
the damaged section, reheat the very mater ial that has been taken out, together with a small amount of flux
Where Used-- How Laid
which can be obtained from us, and then re lay it. The new spot,
Johns- Manville In
floated and rubbed
dustrial Flooring can
down to the proper
be used for practically
level, immediately be
every condition in can
comes one piece .with
ning factories, railroad
and has all characteris
and machine:
tics of the surrounding
passenger and? freight
floor, naturally so, be-
stations, loading plat
cause itis the same
forms and docks, ware
houses, freight .houses/ factories, roundhouses, cold storage, plants,: battery houses, chemi
Johns-ManVille 'Industrial .Flooring is un: . equalled, for. .freight and. passenger station . platforms, A typical, installation- 'for the
Southern Railroad, at Mobile, Ala.
Of particular interest is the tabulation of. properties of various floorings shown on
cal laboratories,
C. A. buildings, page 212, which is the result of actual
creameries/ packing houses, office build tests of all the materials mentioned.
ings, school buildings, and institutions of every kind.
It can be laid over any foundation which is firm and stable such as wood, brick, con crete or tile already in place, in any de sired thickness up to 3". The usual stand ard thickness is 1*4" which affords maxi mum service at a commensurate cost. Can be laid in sections of any size and its in stallation does not necessarily occasion any
This tabulation affords a direct compar ison of the merits of Johns-Manville In~; dustrial Flooring with others.
It is always dense, yet it has a certain amount of resiliency which prevents foot soreness and fatigue commonly caused by concrete and other non-yielding floor sur faces. Where employees of machine shops, factories and other operations are compel
delay in the routine of operation of a plant. led to stand while at work this adds greatly
It adds very little to the dead load of to their comfort and efficiency. Further
the building as the standard thickness more, being dry and warm it is a protec-
211
CRMC-003575
Johns'Manville Service to Railroads
tion against rheumatism and other ailments common to damp flooring conditions,
\-iri ti -vr tiTt ^ * i
Why Johns.'Manville Industrial
Flooring IS Superior
It is tough and elastic, it will withstand
extremes of temperatures far better than
any other monolithic floor and will not
chip, crack, crumble
^
for factory and warehouse use even under the heaviest trucking conditions and on account of its noiseless character is a boon where traffic conditions and
the consequent noise is objectionable.
If your past experience has proved the old-fashioned types of flooring inadequate to your needs; if you are looking for a floor
^ ^ wh^ich ^will gi^ve
points of. superior- - -
,, . ,T ,
.tv'-'- ' r_ : , ,
, . Thompson Chemical Laboratory,. Williams College,
Ity are, brought out , Wiliiamstown; Mass., where johns-ManvilieAcid-
by the Underwrit- proof Industrial Flooring >vas Chosen for its many
-ers test, excerpt. s -
' excellent. qualities as well as its acid resistance.
in
..
the
iy, e. ar
in
many .
Snop IlOOrs where
the traffic IS most
severe and, not.hi.ng
of which are shown on pages 213 and 214. but an exceptionally rugged floor could
VV'here:light or accurate machinery is in last. One notable example is in the Cana-
operation or merchandise is stored Johns- dian-Pacific Ry. Shops, Calgary, Alberta,
Manville Industrial; Flooring is peculr... where 400,000 sq. feet--nearly ten acres--
iarly satisfactory because -it does not or- are in service, the largest floor area ever
or hold dust. . It is unequalled , laid at one time with Industrial Flooring.
PROPERTIES OF VARIOUS FLOORINGS
Industrial Common Paving Flooring Brick wrick
1. Acid Resistance.................... ----- -------100 80 100
. 2. Alkali Resistance.................
...100'
95 100
.3. Durability .............................
75 60 100
4. Elasticity ............................... ................. 60 0 5
5. Fire Resistance .................. ........ 75 100 100
6. Non-Abrasion .................... ................. 95
0 30
7. Non-Slip
............... 100
100
30
8. Quietness ............................... ............... 75
10
5
9. Resilience ............................... ............... 90 0 4
10. Sanitary ............................. ............... 70
6 50
11. Thermal Insulation............. ............... 60
10
0
12. Waterproof ........................... ................ 100
0 10
ConCrete
50 70 90
1 100
10 70
5 1 40 5 60
Maple
30 90 50 90
0 95 50 50 90 35 90 25
Average ............................... .....................83.3
38.4 44.5 41.8 57.9
Oak .
33 90 50 90
0 95 50 50 90 35 90 25
Pine
30 90 ` 40 90
0 88 60 60 90
0 90 25
58.2 53.6
Note the very high average for Johns-Manville Industrial Flooring 212
CRMC-003576
Johns-Manville Service to Railroads
We shall be glad to make a small in stallation knowing that the results will demonstrate conclusively the many ad vantages of Johns - Manville Industrial Flooring. Why not try this plan in some part of your plant where other floorings have not given proper service? It will af ford an opportunity to make a personal test of Industrial Flooring where you can
convince yourself by actual use. Let us know your conditions. We will recom mend the proper consistency and put in a test section. You will then be able to de termine that it is BEST BY TEST.
Our Engineering Department will be glad to confer with you on any of your flooring problems.
Johns-Manville Industrial Flooring as Fire Retardant
odern
M building practice de
mands that as many
Properties" the re port of Underwrit ers' Laboratories, Inc., says of Johns-
of the materials as
Manville Industrial
possible be fire-re
Flooring:---
sisting to the great est possible degree. The following facts
"The top flooring isn o t readily inflam mable and does not.
on Johns - Manville Industrial' Flooring, will answer your rn.o s t .searching questions as to its. ability to retard fire.
: A. few years ago the National Board
Showing how J.ohns-Mativille Industrial Flooring" is laid. . The ;care used;.in selecting and. mixing the proper- materials, for each condition and the skill of these workmen in; application assures uniform re-
' ' - suits and satisfactory service.
carry or communicate, fire to any material-ex tent It disintegrates, slowly under- heat, af fords.. very v consider able . heat insulation to-> the floor.structure.,and-., the progressive disin tegration does not ma
of Fire Underwriters completed exhaust ive tests to determine the fire-retardant qualities of Johns - Manville Industrial Flooring.
The following excerpts from their re
terially reduce the insulation afforded. "By comparing a sample of the `Industrial' top
flooring with a sample of the maple flooring, it will be seen that the maple flooring was readily inflammable and carried and communicated fire to a material degree, giving off flame in consid
port (dated August 21, 1917) substantiate erable volume and more or less smoke. By re
our claims for our Flooring as a fire-re tardant and the excerpts are vitally impor tant to every one interested in flooring for industrial and mercantile plants, pub
ferring to the logs cf tests it will be seen that flames developed on the maple sample in 1 min ute and 45 seconds after which it burned readily and spread rapidly, reaching the unexposed end of the sample in 20 minutes.
lic and private institutions, shops, brew
"In the case of the `Industrial' sample, flame
eries, packing houses, laundries, railway buildings and all floors where the service is particularly severe.
Under the heading of "Fire-Resisting
developed in 5 minutes and 50 seconds and spread slowly, giving off short, intermittent flames. At the end of the test (1 hour and 10 minutes), it had only reached to a point 6 feet from the ex posed end of the sample. At the end of the test,
213
CRMC-003577
Johns-Manville Service to Railroads
after the exposing flames had been extinguished and the gases of combustion given off from the wood at the edges of the sample had been quenched with water, the surface of the sample ceased to burn."
In addition to their findings concerning
the fire-resisting qualities of Industrial Flooring the Underwriters' Laboratories, Inc., also included in their report much interesting data on its design, construc tion, practicability, durability, etc. Quo tations follow:--
Design and Construction
"The design and construction of the top floor ing are suitable for the purposes intended. The materials are suitable for the purpose, forming a
homogeneous mass which can be readily in stalled under ordinary service conditions."
Practicability
"It is practical to prepare the materials as furnished to the job and to apply them in the manner advocated. The flooring can be easily re-
paired or maintained if repairs and maintenance are required."
Durability
"All floorings examined in the field were sub knowledge of the materials used indicates that, if
ject to hard usage and in no case was there any anything the top flooring should have a preserva-
apparent deterioration from the effects of wear. tive effect.
"In .none of the. installations examined was
"Although the; floorings were carefully exam
there any evidence of deterioratioii- in the top ined for cracks which would ordinarily indicate
flooring due to expansion, contraction or settle failure of the surfacing to conform to the expan-
ment of the building. In only one of the.instah . sion and,contraction of the main flooring in which
lations examined- was the top flooring exposed to. it rests,: no cracks were discovered, indicating that
the elements, but this 'installation appeared to be the surfacing is not open to criticism.in this par
in good condition.
V;,'
ticular. In only one of the installations examined
"While the investigation did not give positive was the flooring exposed to the elements, but no
evidence to the effect that the top floor has no criticism developed in the case of this installa
deteriorating influence bn the floor structure, a tion."
"This flooring material, by offering a relatively high resistance to slipping, should reduce the accident hazard due to this cause. . "The examination of the material indicated a structure presenting a suitable anti-slip surface both when new and worn.
"The friction tests brought out results compar
ing favorably with results of test on anti-slip sur faces which have proven to be effective in reduc ing accidents due to slipping.
"Examination made in the field showed no marked difference in the resistance to slipping after being subject to actual service conditions."
214
CRMC-003578
Johns-Manville Service to Railroads
Specifications for Johns-Manville Standard Industrial Flooring Over Wood Sub-Base
1
Over the wood sub-base lay a heavy rosin-sized building paper lapping same one-half its width.
2
The Johns-Manville Standard Industrial Floor ing Blocks shall be delivered on the ground, plainly marked with the brand and broken up before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral aggregate shall then be added and thoroughly mixed into the mass by use of iron stirring rods and the temperature of the mixture brought to 450 F. The material shall be frequently stirred to prevent burning and then removed from the kettles in oak buckets or all iron wheelbarrows and taken to the work as required.
coarse sand, gravel, trap rock or any crushed stone of sufficient hardness.
4
This flooring shall be laid in one course to a thickness of 1", spread with wood floats and suffi cient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint al ready on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats.
5
The top surface of the floor shall be given a
sand finish in the following manner: The top
surface while hot shall be sprinkled with a fine
dry sharp sand, which shall be thoroughly rubbed
into the surface of the flooring and the surplus
sand allowed to remain on the floor until the
same is put in use.
6
The mineral, aggregate shall be thoroughly, dry .: In case of a cement finish the top surface shallbefore being introduced into-the, mix and shall: be sprinkled and. rubbed with sharp sand, which be a clean, well graded material of.:a .size, to\meet ;. shall then be swept off while the material is still, the., particular.'; service conditions encountered.: , warm. . The surface shall; then .be dusted with The . mineral aggregate, is to consist -of a sharp, r Portland .Cement, and .same thoroughly rubbed in;-
--OR*--
. This .flooring shall ,be laid- in one course to a already on the floor and allow it to remain until
thickness of
spread with wooden: floats and ..the, same is thoroughly heated. The surplus ma-.
sufficient pressure applied to eliminate all 'voids . terial shall then be cut off and the . joints made
and blowholes.; When the joints are made, place ; compact arid tight by rubbing with wood floats, the hot mixture over the cold edge of the joint
--OR*--
This flooring shall be laid in two courses to a total thickness of 154". It shall be spread with wood floats in such a manner as to avoid; bring ing the joints in the two courses directly over each other, and these joints shall be lapped at least 12" and sufficient pressure applied to elim inate all voids and blowholes. When the joints
are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats.
Preparation of Floor Surface
(To be incorporated in Carpenter s Specifications)
The wooden sub-base shall be securely nailed and free from loose ends or sharp projections and pitched, if necessary, to proper grade for drainage.
It shall be of sufficient strength to support the loads contemplated,
*Where either of these alternates is used it should be substituted for paragraph 4 in the complete specifi cation above and paragraphs 1, 2, 3, 5 and 6 included.
215
CRMC-003579
Johns-Manville Service to Railroads
Specifications for Johns-Manville Standard Industrial Flooring Over Concrete
i3
The Johns-Manville Standard Industrial Floor
This flooring shall be laid in one course to a
ing Blocks shall be delivered on the ground, thickness of 1", spread with wood floats and suffi
plainly marked with the brand and broken up cient pressure applied to eliminate all voids and
before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral aggregate shall then be added and thoroughly mixed into the mass by use of iron stirring rods
blowholes. When the joints are made, place the hot mixture over the cold edge of the joint al ready on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats.
and the temperature of the mixture brought to
4
450^ F. The material shall be frequently stirred
The top surface of the floor shall be given a
to prevent burning and then removed from the sand finish in the following manner: The top
kettles in oak buckets or all iron wheelbarrows surface while hot shall be sprinkled with a fine
and taken to the work as required.
dry sharp sand, which shall be thoroughly rubbed
into the surface of the flooring and the surplus 2 sand allowed to remain on the floor until the
The mineral aggregate shall be thoroughly dry same is put in use. before being introduced into the mix and shall-
5
be a clean, well graded material of a size to meet
In case of a cement finish the top surface shall
the particular service, conditions encountered, be sprinkled and rubbed with fine sharp sand,
The mineral aggregate, is to consist of' a. sharp, which shall then be.swept off while the material is
coarse:-sand, gravel, trap rock or any crushed, still warm. The.surfa.ee shall then be dusted with
stone of..sufficient, hardness. . .
. Portland Cement and same thoroughly .rubbed in.
--OR*--
' This "flooring, shall;be laid in one course ;to .a
thickness of
spread, with wooden .floats and
sufficient pressure; applied to eliminate .all voids
and blowholes. ; .When, the joints'are made,' place
the: hot mixture over 'the'cold' edge of the joint
already on the floor and allow it to remain until same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight-.by -rubbing, with wood floats:
This .flooring shall be laid in two courses to a , totalthickness of /lpj".. It shall'be spread with wood floats in such a manner as to avoid bring ing the joints yin .the two courses directly over' each other, and these joints shall be lapped at least 12" and'sufficient pressure applied fo elim inate all voids and blowholes. When the joints
are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The' surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats.
Preparation of Floor Surface
(To be incorporated in NqsotCs Specifications')
After the concrete base has been placed and pitched, if necessary, to the proper grade for drainage, it shall be given a screeded and floated surface free from all sharp projections or offsets
of any character except those shown on the plans, The concrete shall then be allowed to set and dry out.
*Where either of these alternates is used it should be sustituted for paragraph 3 in the complete specifi cation above and paiagrapns 1. 2. 4 and 5 included.
216
CRMC-003580
Johns-Manville Service to Railroads
Specifications for Johns-Manville Acid-Proof Industrial Flooring Over Wood Sub-Base
1
Over the wood sub-base lay a heavy rosin sized building paper lapping same half of its width.
2
The Johns - Manville Acid - Proof Industrial Flooring Blocks shall be delivered on the ground, plainly marked with the brand and broken up before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral aggre gate shall then be added and thoroughly mixed into the mass by use of iron stirring rods and the temperature of the mixture brought to 450 F. The material shall be frequently stirred to prevent burning and then removed from the ket tles in oak buckets or all iron wheelbarrows and taken to the work as required.
3
The mineral aggregate shall be thoroughly dry before being introduced into the. mix and . shall be a- clean,, well, graded material of a size to meet the ' particular ' service conditions' encountered.
The mineral aggregate is to consist of fine silica sand, silica pebbles, certain trap rocks or any crushed stone or granite of sufficient hardness and which is immune to the action of all commer cial acids, except hydrofluoric.
4 This flooring shall be laid in one course to a thickness of 1", spread with wood floats and suf ficient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint al ready on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats.
5
The top surface of the floor shall be given a sand finish in the following manner: The top surface while hot shall be sprinkled with a fine dry sharp sand, which shall be thoroughly rubbed into the surface, of the flooring and the..surplus sand allowed to remain on' the floor ..until" the same is put in. use. .
__OR*--
This flooring shall be laid in -one: course to a
: thickness of: 1
spread with wooden floats and
sufficient pressure, applied to eliminate'Sail voids
. and'blOwholes. When the joints are made,' place
the hot mixture over the cold edge of the-joint al
ready on the flobr;and allowTt-to remain until, the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood, floats.
_OR*^
This flooring shall be laid in two courses to a
total thickness of
shall be spread with
wood floats- in such a manner as to avoid' bring- -
ing the joints in the two courses directly over
each other, and these joints shall be'lapped at
least 12" and sufficient pressure applied to elimi-
nate all voids and blowholes. When the joints
are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats,
Preparation of Floor Surface
(To be incorporated ui Carpenter's Specifications)
The wooden sub-base shall be securely nailed and free from loose ends or sharp projections and pitched, if necessary, to proper grade for drainage
and shall be of sufficient strength to support the loads contemplated,
"Where either of these alternates is used it should be substituted for paragraph 4 in the complete specifi cation above and paragraphs 1. 2, 3 and S included.
217
CRMC-003581
Johns -Manville Service to Railroads
Specifications for Johns-Manville Acid-Proof Industrial Flooring Over Concrete
1
The Johns - Manville Acid - Proof Industrial Flooring Blocks shall be delivered on the ground, plainly marked with the brand and broken up before being placed in the kettles. There shall then be added the proper percentage of Flux and both allowed to cook until the blocks are entirely melted. The proper percentage of mineral ag gregate shall then be added and thoroughly mixed into the mass by use of iron stirring rods and the temperature of the mixture brought to 450 F. The material shall be frequently stirred to prevent burning and then removed from the kettles in oak buckets or all iron wheelbarrows and taken to the work as required.
2 The mineral aggregate shall be thoroughly dry before being introduced into the mix and shall be a clean, well graded material of a size to meet the particular service conditions encountered, The mineral aggregate is to consist of fine silica sand; silica pebbles, certain trap rocks or any
crushed stone or granite of sufficient hardness and which is immune to the action of all commer cial acids, except hydrofluoric.
3
This flooring shall be laid in one course to a thickness of 1", spread with wood floats and suf ficient pressure applied to eliminate all voids and blowholes. When the joints are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats.
4 The top surface of the floor shall be given a sand finish in the following manner; The top surface while hot shall be sprinkled with a fine dry sharp sand, which shall be thoroughly rubbed into the surface of the flooring and the surplus sand allowed to remain on the floor until the same is put in use.
--or*--
This flooring shall be laid in one course .to a thickness of l%", spread' with wooden floats and .sufficient pressure-applied to eliminate all voids and blowholes^ When the joints are made, plate the' hot- mixtures, over'the cold edge of the joint
already on the floor and allow it to remain until the same is thoroughly heated. The surplus ma terial shall then be cut off and the joints made compact and tight by rubbing with wood floats*
--OR*--
This flooring shall be laid in two courses to a totaFthickness of IJ2". It shall be spread with wood floats in such a manner as to avoid bringingUhe joints in the two courses directly over each other, and these joints shall be lapped at least 12" and sufficient pressure applied to eliminate all voids and blowholes. When the joints
are made, place the hot mixture over the cold edge of the joint already on the floor and allow it to remain until same is thoroughly heated. The surplus material shall then be cut off and the joints made compact and tight by rubbing with wood floats,
Preparation of Floor Surface
(To be incorporated in il/ason's Speci/icotionsJ
After the concrete base has been placed and pitched, if necessary, to the proper grade for drainage, it shall be given a screeded and floated surface free from all sharp projections or offsets
of any character except those shown on the plans. The concrete shall then be allowed to set and dry out.
*Where either of these alternates is used it should be substituted for paragraph 3 in the complete specifi cation above and paragraphs I. 2 and 4 included.
218
CRMC-003582
J ohns-Manville Waterproofing and
219
CRJVfC-003583
Johns-Manville Service to Railroads
Waterproofing--What It Is
ATERPROOFING is a broad crete recommends abandoning this
Wterm often misapplied and misun method. derstood. In reality waterproof ing should only be thought of in the pres The Membrane Method-
ence of seepage or where there is actual water pressure arising from such seepage and pressure conditions. Every other case of "waterproofing" properly comes under the head of Damp-proofing. For these conditions Johns-Manville can sup ply you the proper materials for either prevention or correction.
Why It Succeeds
This method provides for the applica tion of a protective bituminous skin or membrane over the surface to be water proofed as shown in details on page 224. The membranous covering of waterproof ing asphalt, reinforced with suitable fab ric or felt or both, is strong and flexible
Damp-Proofing
and has the necessary characteristics to resist water pressure and enough "give"
Damp-proofing is protection against to bridge over hair cracks in the concrete
moisture where no actual water pressure due to temperature changes.
is encountered. It is simply the preven
The membrane is built up in as many
tion of dampness penetrating walls or plies of reinforcing' material as is neces
floors.
:1
sary to meet the conditions, and these plies are bonded together and to the concrete
Two Methods of Waterproofing,
Integral and Membrane
with asphalt cement. It is conceded that a carefully com
bined asphaltic compound is the most ef
It is an accepted-fact among engineers fective and durable waterproofing sub
and arehitects.that there are but two meth- stance in existence. As the base of all
, ods of waterproofing, but it has been provx : Johns-Manville Waterproofing materials
en that ONLY ONE of them is capable of we have chosen Gilsonite which is the pur
giving permanent, positive results. .
est form of asphalt known. However, in
spite of its great purity, Gilsonite requires
The Integral Method-- Why It Fails
special preparation before it can be suc cessfully used commercially. By our ex clusive process of refining and combining
This method provides for the incorpora... tion of a powder, paste or liquid into the
concrete during- its construction. It is mixed with the cement, becomes part of the' mass and is supposed to add to the density of the concrete to such an extent
other natural asphalts with Gilsonite, it is rendered remarkably ductile and adhesive, characteristics which adapt it more per fectly than any other material to with stand the peculiar and exacting condi tions of service to which it is subjected.
as to prevent the seepage of water. It fails when hair cracks or larger open
ings develop in the concrete, due entirely
Johns-Manville Membrane Waterproofing
to expansion and contraction or unequal In selecting a material for waterproofing
settlement in the structure. The Joint purposes, the first consideration is dura
Committee on the Waterproofing of Con bility. Waterproofing that is not perma-
220
CRMC-003584
Johns"Manville Service to Railroads
nent is a mere makeshift and actually worse than none at all because of the ex pense, inconvenience and loss of time in connection with correcting it, to say noth ing of the damage generally caused by its failure.
Johns-Manville Membrane Waterproof ing is the result of years of experience in
the successful waterproofing of every con ceivable type of construction. It has been proven by actual experience to be the most economical, not in the first, but in the last cost, and the most satisfactory because IT IS WATERPROOF--NOT APPROXI MATELY BUT ABSOLUTELY WATERPROOF.
Material used in Johns-Manville Waterproofing
Johns - Manville
hot. One ton of this
Concrete Primer
This is the first coat ing applied to the con crete, brick or stone
material should cover 3000 square feet of sur face Vs of an inch thick.
Johns-Manville
surfaces which are to
Asbestos
be waterproofed. It penetrates the : surface
Waterproofing Felt
to such an extent as to,
Used as a reinforce
form an anchorage for
ment and to give body
the subsequent water Showing typical application of. Johns?Man- and substantiality to
proofing. It also acts as a cleanser for the
ville Waterproofing, Materials to foundation walls of Buffalo Wat.er .Works, Buffalo, N. Y.
the membrane; ce mented together and
surface, preparing it '
: V bonded to the concrete
for the asphaltic coatings to follow'. The: by t--he- wa. .t.e.Tripr roofing cement. It is made
covering capacity of. this material should , of pure asbestos (rock fibre), thoroughly
run about 100 square feet to the gallon on impregnated with pure asphalt. This is
comparatively, smooth surfaces':
v the only all-mineral felt made, therefore,
:
Johns-Manville
the only material of its kind that is proof ; against water, cold acid, mold and decay,
Asphalt Waterproofing Cement
r ca
for all time. Virtualiy a pliable bituminized otone sheet. Furnished in two
This is applied while hot over the Prim weights, 14 lb., felt in 3 square rolls and
er and is used to cement the various fab 35 lb. felt in 2 square rolls.
rics together into one composite sheet.
Owing to great care exercised during the process of manufacture, this bituminous material is absolutely uniform in charac
Johns-Manville Asphalt Saturated Fabric
ter. It is 99.5 per cent pure and contains Used not only as a reinforcement for
no matter that will disintegrate or decay. the membrane but to give added tensile
Proof against the action of cold acid, al strength. It is an especially strong cotton
kali, brine and water; very slightly affect fabric or duck used in connection with
ed by a wide range of temperatures be Asbestos Waterproofing Felt in as many
tween melting and brittle points. To ap plies as are required to meet the condi
ply this Waterproofing Cement it is tions. Being a loosely woven material, the
heated to 450 deg. F. and mopped on while waterproofing cement, which is mopped
221
CRMC-003585
Johns-Manville Service to Railroads
on hot, thoroughly impregnated, cements if desired with a melting point of 150 deg.
and bonds together the several plies of the F. In lining wooden tanks it is sometimes
reinforcement.
used to coat the tongues and grooves of
the boards when the tank is being built,
Johns-Manville Self-Healing Waterproofing Cement
the boards being drawn tightly together and held in place permanently by the use of wooden dowels. After the tank is
This is an asphaltic compound -which carries a very low congealing point and a melting point of 125 deg. F., although we can furnish it with a melting point of 90 deg. F., when a softer material is desired. The use of this product is naturally limit
erected the inside is primed and given from two to four coats of the Pickling Tank Cement. It is immune to all the cold commercial acids, including hydro fluoric. It is shipped in iron drums weigh ing approximately 400 pounds.
ed for waterproofing purposes on account of its tendency to move readily under
Johns-Manville Expansion
comparatively high temperatures and also
Joint Filler
its extremely viscous nature. For brine
An asphaltic compound of great tenac
decks in packing-house hog-coolers and ity and elasticity. Used for filling expan
for waterproofing work between wooden sion joints. It is capable of taking care of
floors, this material is ideal. We have also certain movement in structures, paying
found that on account of its adhesiveness and road work due to expansion and con
at low temperatures it makes an excellent traction. It is melted and poured into
: expansion-joint filler arid we are using it . place. Immune to the action of street
largely for that purpose. It is shipped in . acids. Shipped in iron drums of approxi
.wooden barrels weighing approximately. mately 400 pounds each.
.500 pounds and; half barrels weighing ap
proximately 250 pounds.
..
Johns-Manville Bituminous Putty
Johns-Manville Pickling Tank Cement
This is ail asphaltic compound; evolved . principally for. use in lining the inside of
wood of concrete tanks where an acidproof coating is a necessity. It is mopped on the surface in a heated condition and carries a melting point of 200 deg. F., al though a. softer material can be furnished
This material is composed of an asphal tic compound and asbestos fibre, used as a filler to prevent the infiltration of water in recesses where a permanent seal is hard to maintain with the waterproof membrane. It forms an elastic, bond but little affected by temperature . change and vibration. Largely used in connection with certain types of bridge waterproofing where the waterproof membrane is sealed to the sides of the girders.
Johns 'Manville Damp -Proofing
In the large majority of cases the appli cation of cold surface coatings will effec tively damp-proof any structure. There are, however, special cases of damp-proof ing which require the membrane method of waterproofing. We firmly believe, and
successful installations prove, that JohnsManville Damp-proofing is the most effi cient system to keep out dampness and to prevent discoloration due to the absorp tion of moisture.
222
CRMC-003586
Johns-Manville Service to Railroads
Johns-Manville
Johns-Manville Aquadam
Liquid Waterproof Coating
This is applied cold over brick, stone or
HIS is used in connection with Johns- tile and concrete surfaces, where it is re-
TManville Concrete Primer, and is ap- quired to damp-proof the walls and proplied cold in one or two coats, for vide a plaster finish over the damp-proof-
damp-proofing only. It is used for wall ing. In tile partitions it prevents dampness
work or for other surfaces not liable to from driving the saltpeter out of the tile,
injury from abrasion and where there is through the plaster and discoloring the
no hydrostatic pressure. It will withstand decorations.
seepage of surface water and prevent the It is applied in one or two coats, de
discoloration or staining of the outside pending upon the porosity of the surface,
face of concrete walls. It has a covering It has a covering capacity of about 80
capacity over smooth surfaces of about square feet per gallon.
2-00 square feet to the gallon when used
--
over the Primer.
All Johns-Manville Waterproofing ma-
_ ... ^ 0
n i
terials are sold on an f.o.b. basis, for appli-
Johns-Manville Cut Stone Backing cation by the user or local contractor.
This is used for coating the sides and back of .cut stone to prevent discoloration ; and dampness of inside or anterior walls, It should cover approximately 6.0 square feet: per gallon over rough surfaces.
The felts are furnished in rolls, ready for use and the various asphaltic cements, putty and coatings are packed in containers most convenient for shipping and handling on the job.
Applying Johns-Manville Waterproofing on side walls. See detail drawings on page 224. 223
CRMC-003587
Johns-Manville Service to Railroads
Details of application'of 3-Ply Built-Up Waterproofing Membrane.
Details of application of 2-Ply Built-Up Saturated Fabric Waterproofing Membrane. 224
CStMC-003588
Johns-Manville System of
Acoustical Correction
225
CRMC-003589
Johns -Manville Service to Railroads
Johns -Manville System of Acoustical Correction
OR the elimination of unnecessary
Fand disturbing sounds, reverberation, echoes and poor acoustics in Railroad
Passenger Stations, Offices, Banks, Thea
tres, Schools, Colleges, Auditoriums,
Clubs and Hotels. The Acoustical De
partment of Johns-Manville Inc. is main
tained for the purpose of conferring
with architects and owners in the design
and construction of new buildings to in
sure good acoustical conditions as well as
to correct poor acoustics in structures
already built. Through its System of
Acoustical Correction the Johns - Man
ville Company is prepared to produce good hearing qualities in auditoriums of churches, theatres, court-rooms and. other public buildings; also to reduce to the mini
Waiting Room, Southern Pacific Railroad, Oakland, California, Jarvis Hunt, Chicago, 111., Architect;
The annoyance of noises common to railroad stations has been eliminated by the installation of Johns-Man-
ville Acoustical treatment on ceilings.
mum the fatigue and. loss of efficiency
due to confusion and noise in. offices, . and these factors must be carefully stud-
banks, hospitals and rooms of similar; led in every case. The nature of the treat
character, resulting from the unavoidable ment, its amount and location, is a matter
concentration of, employees and' noisy, md- for expert determination. The problems
chahical office appliances...
` involved are highly technical and for their
In broad terms., good acoustics requires' satisfactory solution the trained know
that there shall be no confusion or blur- ledge of specialists is indispensable.
ring 7 of speech; or music due to over- Through the Johns-Manville Company,
lapping or interference of tones and syl the services of competent acoustical engi
lables and that everything shall be done neers are available to architects and others
to bring about that clarity of tone which; who have acoustical difficulties to be over
is consistent with the maintenance of suf come. The methods used are based on the
ficient loudness and proper balance. The scientific researches of the late Professor
acoustical conditions of any room are af W. C. Sabine of Harvard University and
fected partly by size and shape, and partly the Johns-Manville Company has devel
by the character of interior surfaces and oped special materials and methods of ap
furnishings, as well as by the distribution plication for producing the necessary cor
and size of the audience or occupants.
rection.
A certain amount of absorption is neces The Johns - Manville engineering ex
sary in every auditorium. In some cases perts are prepared to examine plans and
furniture and the clothing of persons pro specifications at any time, without fee,
vide all that is needed in this respect, but and to recommend suitable treatment
more often artificial treatment is required where it may be necessary.
226
CRMC-003590
J ohns-Manville Electrical Materials
227
CRMC-003591
.?'B Johns^-Manville Service to Railroads
Johns-Manville Ebony Asbestos Wood
johns-Manville Ebony Asbestos Wood has been examined and approved by the Underwriters' Laboratories, Inc., under the direction of the National Board of Fire Underwriters.
OHNS-MANVILLE Ebony Asbestos factor when the loss due to handling more
JWood is recommended for use as an in sulating base for switchboards, panel
fragile materials is considered, and its lightness is in its favor both on the basis
boards, bus bar barriers, switch bases, inof mechanical strength and the saving of
sulators for collector rails on ore bridges freight charges.
and all kinds of cranes, charging and For years the chemical industry has been
drawing machines in coke plants, third looking for an ideal material for labora
rails on top of coke ovens, etc. It is of tory table tops, sink tops, lining hoods
fered in the form of composition sheets over hot tables, and cabinet hood linings.
made up of asbestos fibre and binding
The perfect material would be one
cements and
which would be im
densely impregnat
pervious to chemi
ed under heat and
cals, acids and acid
pressure into; 'a
fumes, one that
compound 6 f very
would.not break
high die 1 e c t r i c
glass containers on
strength. /
::
account of tempera
/This material pos-r.
ture : change when
-. sesses the least pos
they are put down
sible -surface leak
while hot.
;
age, feeing .affected.
The ideal mater
/ neither by oil -nor, atmospheric . mois-
, ;i, .. ,
ture, nor Win- It- rot .
nr rilof pxTpn .when
exposed to the ac-
Sections of switchboards at United Electric Light & Power Co., Hell Gate/ New York City, one of the most,, modern-power stations in the world. JohnsManville Ebony Asbestos Wood was chosen for the huge switchboards and; many other uses because of
its superior dielectric strength, ability to withstand vV1ibUrIaOtViioVnJll-aCknllXdX ashuovcvkfi faiHnUd flirPeCeUdWoMmii furoumiu m414eC1ta01lJlAicI* vWeiinll?s..
......
ial has been discov ered in Johns-Man ville Ebony Asbes tos Wood.
Johns - Manville
tion of water, gas, oil, chemicals or ordi- Ebony Asbestos Wood is taking the place
nary acids. Although comparatively light of slate, porcelain and Alberene stone in
in weight, Ebony Asbestos Wood has hundreds of plants for hundreds of dif-
great physical strength due to its fibrous ferent uses.
structure, hence is free from ruptures due On the next page there are shown some
to rapid temperature changes. It will with- typical uses of Johns-Manville Ebony As-
stand heat up to a temperature of 500 de- bestos Wood in industrial plants. There
grees F. and is not likely to warp, shrink, are uses in your plant--find them--and
crack or buckle under extreme service con- increase your production by reducing
ditions. This strength is an important breakdowns to the minimum.
228
CRMC-003592
Johns-Manville Service to Railroads
Some Typical Uses for Ebony Asbestos Wood
Disconnecting switch bases for lightning arresters
Primary fuse boxes Washers to separate bus
rings Terminal blocks, motor
and generator Back board controllers
Charging rheostats Theatre pockets Theatre expansion plugs Theatre boxes and dus
ters Button switch boxes Wattmeter bases Ground, petticoat and line
insulators
Lightning arrester boxes Panels for switchboards Switch barriers Faces for rheostats of all
kinds Electric elevator controls Shunt bases Fuse blocks Exciter panels
Cabinets for distant con trol of oil switches
Converter panels Barriers to separate units Wire cleats Divider cleats Bus bar supports Resistance boxes Distributing boards
Linings of cabinets Mercury arc rectifier pan
els Solenoid switches Back connected switches Cabinets Small wire holders for in
strument connections Dinkey controllers
INSULATION RESISTANCE IN MEGOHMS PER SQUARE INCH OF SURFACE, AT 18; C.
Thickness
%"..................
Va".............
v%".................. V.................. w..................
___ ____ ____ ____
Resistance As Received,
Megohms
475,000 1,700,000 2,500,000 3,000,000 3,200,000
After 96 Hours Immersion, Megohms
50,000 1,000,000 1,500,000 1,900,000 2,500,000
Thickness
3/4".................. ......... 1" .................. ......... U4".................. ......... ilA".................. ......... 2" .................... .........
Resistance As Received,
Megohms
3,500,000 4,000,000 5.000,000 6,000,000 7,500,000
After 96 Hours Immersion. Megohms
3,000.000 Above 3,000.000 Above 3,000.000 Above 3,000.000 Above 3,000.000
COMPARATIVE TABLE OF PHYSICAL PROPERTIES OF SWITCHBOARD MATERIALS
B-V Marble
Slate
Soapstone
Johns-Manville Ebony Asbestos
Wood
Weight per cubic foot...............................................
Dielectric strength, one inch in thickness.... ... 65,000 V
Insulation resistance: per one. inch cube...... ... 170,000 meg.
Crushing strength per square, inch'........... . 13,000 lb.
. Transverse, modulus of rupture in'lbs. per sq. in..
8901b.,
1801b. 8,000 V
25 meg. 10,000 1b. ,6,2001b..
175 1b.
121 lb
25,000 V,
76,000 V
250 meg. 4,000,000 meg.
'. 8,000 lb. .
15,0001b.
1,300 lb. .
3,500 lb.
NOTE:--The figures in1 this table are the values obtained by actual test, and care should be taken not to use .the strength' ejven : in construction, without a suitable factor cfsafety. The insulation resistance and puncturing voltage of slate, marble and soaostone ' are only approximate; since individual-specimens of the same kin d vary 500 % among themselves';
-
. . 'Th preceding; tabie has beeri-computed'on the'basis of tests made in the dry state and the materials are' considered to have absorbed no moisture..: The results, would be different if figured on tfiie basis of absorption,;
with the exception' of -soapstone\and Johns-Manville; .Ebony Asbestos Wood, which are practically unaffected!' after immersion in water for 'any length of: time. . The result on marble and slate would be considerably re-, duced after immersion in water.
PUNCTURING VOLTAGE
Thickness
Puncturing . Voltage
Average
Thickness
Puncturing Voltage
Average
Thickness
Puncturing Voltage
'Average
Thickness
Voltage: Average
v%........ ... 12.900'
V':.......
37.000
'VA"................ . . . 54,000
IV........ .. 80,500'
Va"........
. S/8 ........ . . . 43,000
1" ................ . . . 66,000
1 Vi ............... .
85,000
... 30,500
2" ................ . . . 96,000
WEIGHTS AND LIST PRICES This material is supplied in standard size sheets 36" x 48", 42" x 48" and 42" x 96" in the following thicknesses:
Weight per
Thickness
Square Foot
y8--............ ...................... 1,50 lbs______
List Price per Square Foot
$0 90
*v*............. v............. .......................2.75
.......................... 1.20 " ... ....................... 1.30
......................3.50 "... ......................... 1.45
W *A" Vs
............. ...................... 4.25 ............. ...................... 5.43
............. .......................6.88
" " ... " ...
.......................... 1.60 ......................... 1.90 .......................... 2.35
Prices on thicknesses above 2" on application.
Thickness
Weight per Square Foot
List Price per Square Foot
74"
9 00 "
............................ $2.50
1" 10 35 "
Wa"
l'A" Wa"
2"
............. ................... 12.85
............. ................... 15.00
.............
17 80
............. ....................20.65
". ". * ".
............................... ...............................
...............................
3.10 3.65
6.20
* Supplied only in sheets 36" x 48".
229
CRMC-003593
Johns-Manville Service to Railroads
Johns'Manville Transite Asbestos Wood
Examined and approved by the Underwriters' Laboratories Inc., under the direction of the National Board of Fire Underwriters,
. Oil switch .compartments and transformer protective cover of Transite Asbestos Wood. Insialled at Station F, Pacific Gas and Electric Co., San Francisco, Calif.
OHNS-MANVILLE Transite Asbestos Transite Asbestos Wood can be fasten-
JWood is recommended for general elec- ,ed with nails or screws, takes any kind of trical construction.use, and is most satr. a wood finish, yet withstands successfully
isfactory where ;_'.fireprdo, heat-resisting,, .the most severe fire tests and sudden
material is. required and. great dielectric , changes of temperature. '' Will not warp;
strength, is not necessary. It has, proven.;. or become distorted! or. weakened in ser--
to be most durable for bus bar barriers, vice; in fact, it actually becomes tougher
transformer doors, fireproof lining or con- with age.
tainers and other, forms of construction . Supplied in sheets .36" x 48", 42" x 48"
. throughout the plant where long-contin- and 42" x 9.6" in various thicknesses from
ued, positively fireproof service is essen-
to 2".
tial.
Some of the Electrical uses of Transite Asbestos Wood
Bases and floors about '. switchboards Washers to separate bus
rings Troughs about wires Lightning arrester boxes
Switch barriers
Shunt bases.
. Resistance boxes
Potential transformer
Charging rheostats
boxes
- EquaiizeJ. bases
Frames for small boards p e b x s Protection from magnetic
blow-outs on railway Panel board hners
cars
Wattmeter bases
Barriers to separate units Wire cleats, large and
small Separation plates for
street car controllers Electric elevator controls
For uses and application of Transite Asbestos Wood for building- purposes see page 1SS.
WEIGHTS AND LIST PRICES OF FLAT TRANSITE ASBESTOS WOOD
Thickness in inches
1
Weight per sq. ft.
1.7 lbs.
2.1 " 2.8 -
3.4 "
Price per sq. ft-
0.15 0.225
.30 .38
Thickness in inches
J
1
1
Weight per sq. ft.
4.0 lbs.
5.3 "
7.6 "
10.1 "
Price per sq. ft.
0.45
.60
.90
1.20
Thickness in inches
1! 11
l?
2
Weight per sq. ft.
13.0 lbs.
15.7 "
18.S "
21.0 "
Price per sq, ft.
1.50
1.80
2.10
2.40
230
CRMC-003594
Johns-Manville Service to Railroads
Orangeburg Fibre Conduit
Manufactured by THE FIBRE CONDUIT CO., Orangeburg, N. Y.
JOHNS-MANVILLE INC., NEW YORK CITY
SOLE SELLING AGENT
RANGEBURG fibre conduit is a Standard Specifications--General
Obshuearcgrdti,oFntio.burIegnhCmocaonnndudufuiat,ict,tBuceryinnldignsdOrairncadanlgFeinittinwgist1h.
It shall be thoroughly insulating compound.
impregnated
wet wood pulp fibre is formed on a
2. The walls shall be compact and
mandrel to the desired length and
incapable of separation into layers
thickness of wall. The individual
when heated to 212= Fahr.
fibres become felted into and form a
3. The material shall not be af
solid, homogeneous wall. Taken off
fected by acids which may be present
the mandrel, the wet pulp structure is in the ground and shall itself be free from
subjected to a drying process, after which any substances which might corrode the
it is placed in a vat of bituminous impreg sheath of leaded cable.
nating liquid compound. There are suffi 4. The bore shall be straight, the
cient creosote salts in the compound to cross-section shall not vary at any point
kill any vegetable matter or bacteria more than y8" from a true circle and
that might cause
the inner surface
decay. This coin-
shall: be free from
pound is therefore
dents or other ob-
a thorough pre-: servatitfe,. and. is a Iso' insu 1 atioh
arid waterproofing. It thoroughly pei>::
fneates the entire structure, . so that, after treatment the wall of; the con duit, when cut, presents a strong resemblance to hard rubber. The ends are tooled in a lathe to make Socket or Har rington joint, as may be desired. Stock is stored in winter and sum mer in the open yards of the manfacturing plant.
Fibre Conduit installation by "built-up" method. Grooved
moulded concrete separators hold tiers of conduit in posi tion to pour concrete in a single operation.
structions, as gauged by' ability to: pass a 36'' long mandrel of less diameter than the nominal size of the conduit. : 5. The i.nne: surface shall b< free from excesi surface o f com pound and fron r o ugh or flak} areas.
6. On size: from 2'' insidt diameter to 4%' inside diameter lengths shall be ! ft., with the excep tion of not mor< than 15% whicl may be furnishec in lengths shortei
231
CRMC-003595
Johns-Manville Service to Railroads
than 5 ft. but not less than 3 feet. On sizes 1". and 1%" inside diameter as sorted lengths shall be furnished from 2y2 ft. to 5 ft. in multiples of 6".
The Harrington Joint Type
This type of joint is made with both ends tapered. The sleeves are also tapered, there by allowing more ``swing'5 to the conduit
Types of Joints
than can be secured by other types of joints. With this type the conduit does
not butt, permitting greater flexibility.
Orangeburg Fibre Conduit, Bends and
Fittings are made with two types of
Special Sizes of Fibre Conduit
joints; namely, Socket and Harrington. Fibre conduit can be made on special
Each type has its advantages for certain order up to 18 inches in inside diameter.
different types of applications. List prices For prices and delivery on special material
are given in the succeeding pages. Prices apply to the nearest Johns - Manville
and promises of delivery on special Branch.
material can be secured from the nearest
Special Bends
Johns-Manville Branch.
Special bends can be formed to dimen
sions desired,
The Socket Joint Type
The/Socket or mortise, and ten'on: -connections that are. cut on ;: the ends; of each;, length of .Socket:/ Joint v Orange- ; burg Fibre' Con duit are ; autom a; t i c a 1 1 y turned, slightly tapering and uniform in size.
Fibre Conduit incorporated in retaining wall.
within the limits given in the table below, if not mitred. If mitred any de gree or radius desired may be obtained and the bend can be made anywhere in length of standard pipe.
These bends are made only to . order.
As the joints are automatically formed,
the connection secured in laying the con duit is perfect in fit and alignment. The inside of the joint is reamed during the process of cutting so that there can be no offset at the joints when laid.
The flange of this joint also serves to exclude the cement when concrete is poured.
SWEEP BENDS
Not Mitred I- D. in Shortest Radius
Incnes
Inches
1 .... 8
........ 12
2 ........ 18
2/2 ........ 24
3 ........ 30
3 54 . ........ 36
4 ........ 36
454 ........ 36
"S" BENDS
I. D. in
_
Max. off-
Not Mitred
Inches set, Ins.
1 .. . 16 .. . 8 Wz ... 36 .. .. 18
2 ... 36 . 18 2'A . .. . 28 . . . 24 3 ... 24 .. . 36
. .. . 20 . . 36
4 .. . 20 . . . . 36
41 < . . . 20 . . . . 36
232
CRMC-003596
Johns-Manville Service to Railroads
Advantages of Fibre Conduit
the sheath becomes seriously abraded
1. Low initial cost. Small percentage
w; or cut. Orangeburg Fibre Conduit
of breakage. Low freight cost per foot.
joints prevent seepage of concrete.
Minimum space in duct line. Easy to
Lack of protection to the cable in the
handle. Low cost of finished duct.
duct is usually in the form of loose and
2. Strength. Building excavations and non-waterproof joints which allow stray
short circuits have the minimum amount currents access to the cable.
of damaging effect on fibre conduit.
Orangeburg Fibre Conduit when prop
3. Ease of cut
erly laid provides
ting and con
a duct in which
necting into a
all joints are
fibre duct; and
watertight. Ad
ease of avoiding
vantages of this
obstacles.
are obvious
4. Ease of pul
where electroly
ling cable in or
sis is likely to
out -- minimum
prevail.
of damage to cable.
Uses of
5. Ducts can
Orangeburg
be spread to en
Fibre Conduit
ter manholes. 6. Damaged
duct r em a i n s useable ."after, .se? verecablefailure. 7. Can be in
Installatiori.'. of ' Fibre .'Conduit,, Switchboard : Floor, between lines-."E" and .-`F'V at' United'Electric Company, Springfield., Mass., Stone and-Webster, Inc.,' Engineers .and Contractors.'
While the largest field of application for Ora n g e bur g .Fibre Conduit has been in elec-
stalled "rapidly
-AA'",
trie service un
--an advantage in :a.busy street. ...
j. derground-systems,; this product: has also-
8. Will not warp,-".'stick.. or. grip cable,;, been applied satisfactorily in many special
either-from the effect, of 'moisture or heat. fields. I.t has been; used as a conduit for
. Checks fire, in case of; arcing. "< "
electric conductors on electrified railways;
Protection of Cables
it has been laid in concrete forms for com ducting power house cable systems and for
It is a recognized fact that about 90 per cent of all underground cable trouble is directly traceable to some injury to the lead casing of the cable, which takes place when the cable is being drawn into the duct; or to lack of protection which should be afforded to the cable after being placed in the conduit. The injuries to the cable
leaders from aerial lines to underground ducts. In addition to this, certain other special applications have been successfully tried but it is recommended that before Fibre Conduit be purchased for applica tions other than the above, the matter be taken up with the nearest Johns-Manville Branch.
while being drawn in are usually caused by burrs or blisters on the interior of the
Approved by the Underwriters
conduit, or to nipples of concrete that The Underwriters' Laboratories, Inc.,
have seeped through the joints, formed have approved Orangeburg Fibre Conduit
and hardened on the bottom of the duct. for use in electrical generating and sub
In drawing the cable over these defects stations when laid in concrete.
233
CRMC-003597
Johns-Manville Service to Railroads
Price List--Schedule "A" Covering Standard Material
Prices F. 0. B. Factory
Subject to Change Without Xotice
AN EXTRA CHARGE WILL BE MADE FOR BENDS OF SPECIAL DEGREE OR RADIOS, FOR CUTTING TO SPECIAL LENGTH, FURNISHING MATERIAL TO SKETCH AND MATERIAL COT TO WASTE
Inside
FIBRE CONDUIT Diameter,
Inches
Price per Foot
Standard
Crate
contains, Feet
Approximate
Gross Weight
Standard Crate, Pounds
Approximate No. of Feet
Minimum Carload
30,000 Lbs.
Socket Joint
2 So. 10 200 270 33000
2H .11 200 320 27000 3 .12 150 285 22800 3H .13 125 290 19800 4 .15 100 280 16000
4H . 19 100 330 13200
2 SO. 13 200 295 31300
Harrington
2'A . 14 200 355 24750
Joint
3 .15 150 320 21250 3H .16 125 320 18000
Coupling Included with
4
.18 100 320 14850
AU . .23-
100
380
12000
Maximum No. of Feet
in 36 Ft. Car
Approximate
Gross Weight Maximum
Quantity 36 Ft.
Car, Lbs.
Approximate Net Weight
per Foot,
Pounds
35000 30000 25000 21000 16500 13300
31800 33250 32800 31800 30800 30250
0.90 1.10 1.30 1.50
1.85 2.25
33000 27000 23000 20000 16000 12000
31600 32700 32500 . 33300 32300 30000
0.95 1.20 1.40 . 1.65 2.00 2.50,
.
BENDS. AND FITTINGS
Inside
Diameter, Inches .
. Standard Bends,'.Each
...Standard Crate, of Bends' contains . Pieces
Approximate.
Gross Weight Standard
Crate Bends, Pounds
Radius, . Standard . 45= &,90";'
.Bends
. Radius,/
1 Standard ... ^`S'-.'Behds ' i.20" Offset i
Elbows,, , -Each
Extra
Couplings.' Each '
Socket-. . Joint:.
.'Si:. 75';
' ' -2-hL:. . 1:80
:'X: a 1785
. .. 3K
. 2 : 00 .
.'4 7 2. 25:
' A1 2 ; ..3.25
'
25 25 20: .15 12
9
255
295 280 295 295 250
- 18"-24-`-36,/ 2.4':-36"
' -36'" -36"".': 36".
- 36"
36" "; v- 367 ' 36"...
" 36" "' 36" 36"
S2.15 2.15 : 2.20 . 2.20
7 2 .25 3.00
' 2
$1V90 '
25
265 18"-24"-36" ; 36"
Harrington
" 2J2 -.'2.00
25
310 24"-36"
. 36"
3 2.10 20 290 36"
36"
. 3 Vo
2.30
.15 - 310
36"
36"
Coupling Included with Each Bend or Kitting
4 41
2 60 3.65
12
9
305 260
36" 36"
36" 36"
$2.25 ; 2.25 2.35 2.35 2.45 3.25
.$0.10 .11
-12 .14 .16 .20
it.cy.zr joixt type
234
karrixcto.v joint tvpe
CRMC-003598
Johns-Manville Service to Railroads A Few Standard Bends
45 Bend--5' Long, 36" Radius--Socket Joint
"S" Type Bend--Socket Joint
90 Bend--5' Long, 36" Radius--Socket Joint
Elbows
Dimensions below are in inches and only approximate:
4 90 ELBOW
: 45' ELBOW
D 2" 2A 3 314 4 Ay2. 2 2J4 3 3$4 :-;4 4J4
;r
. ill e - 'G
2y2 214 3
6 6^ 6#
3 3A 4A:2A 2A 3 .3- 314 414 7 7A s:
'8# .9. 9 9y2 10* 12
.Socket Joint
T J4; A A A A ft.- A \A A.
A iV
Harrington Joint
L 14
14
A
A
A
A:: !4
A
A
14
14
A
Trade Customs
The right is reserved to ship from any of our plants. Sales subject to strikes, accidents or causes beyond our control.
Every piece of conduit is carefully inspected, but as it is impossible always to detect imperfections, the only guarantee that is given by us is to replace such goods as prove defective or allow credit for such goods at our option. Under no circumstances are we responsible for any damages beyond the price of the goods. No charge for labor or expense will be allowed. If the goods are defective, the measure of damages is the price of the defective pieces.
No material will be taken back and credited or re placed unless arrangements for such return have previ ously been made.
The carriers are responsible for the goods lost or
damaged in transit, therefore, as required in Rule 3 of Uniform Bill of Lading, in case of loss or damages en route, consignee must immediately notify the railroad agent at destination in writing in order to substantiate formal claim when presented.
Claims for shortage or deductions or erroneous charges must be promptly presented with full details or will not be allowed.
Special goods made to specification, where buyer is to inspect, must be inspected and accepted before ship ment is made. After shipment is made, our respon sibility ceases.
Requests for cancellation of orders calling for odd sizes or cut lengths, will not be considered if the man ufacture of the material has been commenced when the request reaches the mill.
235
CRMC-003599
Johns~Manville Service to Railroads
(Pat. App. For)
JOHNS - MAN VILLE INC.,- Sole Selling Agents
A flexible system of distribution for service ^vires through ducts
integral with the concrete floor
RANGEBURG underfloor duct sys-
O tern molds a network of wire tun nels in the concrete floors of mod-
Description: The system consists of fibre ducts laid in the Concrete of the floor in parallel lines sufficiently close one to
; erri firesafe buildings which by such intchlueother that, wherever electrical machin
sion become ah integral part of the struc ery or apparatus may be placed, it will be
ture. The specification of this system obvi
ates for all time mutilation of walls arid floors; reduces to practically the bare cost of the wire itself the expense of additional electrical facilities or the rearrangement
over one of such lines. At convenient dis tances and at right angles are constructed header lines of the same duct, connected to these distributing lines and extended to the floor wiring centres. To the duct, ac
of old; removes the hazard of exposed cess is had through an insert or outlet fit
wires, their unsightliness and the failure ting placed through the finished floor and
of the apparatus they serve, through their floor covering. Such outlets are only es
liability to interference and damage; and tablished as needed and if subsequently
makes available for electric service every abandoned are closed in a simple manner,
possible location at which apparatus or being, however, immediately available if
equipment may be wanted.
wanted again.
236
CRMC-003600
Johns-Manville Service to Railroads
where service might be required at least twice as many outlets have been installed as were finally used.
In the Orangeburg system no outlets and no wire are installed until service is required and then only for the necessary requirements. Subsequent additions are as cheaply made as would have been the case had they been included in the original installation.
Two systems are offered: a double duct
Showing installation of Orangeburg System of Underfloor Duct in a floor of over 3" fill. Note "pad" or "bench" provided under duct
and inconspicuous floor outlet.
for heavy duty and a single duct for lesser requirements.
In the double duct system, two ducts are run side by side at the agreed spacing be
Duct: Is the well known Orangeburg tween the parallels: one duct for electric Fibre Conduit which through a quarter of light and power wires, one duct for signal a century has come to be the standard of and communication wires.
subway construction, for almost the entire
In the single duct system all wiring is
electric light and power and electric rail- carried in one duct.
way industries. Confidence in its .
It is recommended that the paral-
durability is assured by this record .
lels of the system be spaced from 5 to
as its placement in floors (imbedded :
6 feet apart, the first and last parallels
in concrete) is identical with . its
y from 2% to 3 feet from the adjacent
treatment'in Subway construction.
wall. ; . .
: Jundiion.Soxes .* Of cast iron with brass Headers should be spaced solely on a
tops, and covers ; , strong and .rugged ; will.; basis of estimated wire density, as wire
withstand- rust, and corrosion equally;vfith can be fished to any distance met with in
the building frame; and a rload- weight the floor areas of modern buildings.
equal to the floor in which they are im
bedded;.-
Outlet Fittings : Of cast brass of ade quate design to withstand the; compres sion in the top of floor slab in which they are placed.
Wafer .Exclusion.* Both junction boxes and outlet fittings are provided with dur able gaskets making certain watertight joints at the floor line.
Design
The Orangeburg system distinctly mer its consideration from this point as it en tirely eliminates guesswork in planning.
In systems previously used it has been necessary to install duct, outlet fixtures and wire previous to the occupation of the building. Further, in guessing as to
Installation showing crossunder fitting used when piping crosses the Orangeburg System of Underfloor Duct installation.
237
CRMC-003601
Johns-Manyille Service to Railroads
Standard size
the ceiling below.
ducts used in the
A reasonable num
Orangeburg Under
ber can be accom
floor Duct System
modated by a spec
are 4%" wide and
ial cast iron cross-
2-J4" high over all
under fitting which
and have been in
is installed in the
stalled with entire satisfaction in build
duct line and offsets the line down about
ings with floor fills of only 3". How ever, in most office buildings a fill of
A typical floor plan of duct layout in the American Telephone & Telegraph Company's office building in New York City; 22 stories fitted with Orangeburg
Underfloor Duct; complete installation.
2 leaving a space 4wide and the entire height of the fill through
4y2" to 6" is generally provided.
which pipes may be run as shown on
Where the fill is greater than 3%" a page 237.
concrete "pad" or "bench" should be pro vided so that when the ducts are installed
Finish
on top of the pad the top of the duct will In designing the fittings and duct full
be about 1" or 1%" from the finished floor consideration has been given to both util
surface. (See illustration on page 237.) ity and appearance. The finished floor is
This facilitates the installation of
neat in appearance and in satisfying
fittings and also raises the ducts
contrast to the results obtained with
above the floor slab so that other
other methods of interior wire distri
pipes can cross under the ducts by
bution.
cutting through the pads. ;
Where a fill of only 3" or 314" is provided
For details and specifications of the
any. pipes. which must? cros? the path pf Orangeburg System, apply to the nearest
the ducts should' preferably be cast.in the Johns - Manville . branch or write, dor
concrete floor construction, or installed on pamphlet E-30. , j
. .p
SYSTEM IN REINFORCED CONCRETE
Closed-bottom Duct installed in Office Building, Long Island Railroad Co., Morris Park, N. Y.; Hatzel &
Buehler, Inc., Elec. Contractors.
SYSTEM IN FLOOR FILL
Installation in Western Electric Warehouse Building, N. Y. C-; double grid layout; J. P. Hall-Smith Co.,
Electrical Contractors.
238
CRMC-003602
Johns-Manville Service to Railroads
CRMC-003603
OflAKGftU
Johns-Manville Service to Railroads
240
CRMC-003604
Johns-Manville Service to Railroads
Johns-Manville Friction Tapes
JOMANCO
FRICTION
TAPE
A(;rt*C9 v.
* -O'* *'
Johns-Manville, Inc.
Atb&u Cottuobo
Itaaphis -rimliriiitti
Haitimore Pis^er -l. --
JCBirufett - < ^rtUaOv*r-
Bo<on DefcoSi
Brulalo
71tt\ wwk.J. 8thUeCSt?
Chicago
\ ySa J WOtWs fiuFr*ad*oJ
CitKiredi Ktaa< CSty VJrV HeTi . Se*ffVi. . -
.C!*T*ai 'L*
Os&Jii* * ; . W*to."::.y."
; l4d*vt&
Fhiid^phte
^
,
Careful manufacture of selected materials assures the highest quality in Johns-Manville Friction Tapes. They are better, more satisfactory and more durable in every way.*
OHNS-MANVILLE Friction Tapes : class of insulated joint is required. It is
J : are made of strong,: closely woven fab-. preferred by manufacturers of high-grade ric, heavily impregnated with a specials electrical machinery because of its ability ly treated compound. They have remark- to withstand high voltages. Used for all . able ,adhesive properties and long; life; purposes under the most exacting condi-
are not affected by heat, cold or moisture; tions, it has never been known to fail,
do not dry out with age; contain nothing .. Johns-Manville No. 3 Tape-A popular
to,corrode wires; are free from pin-holes, material for taping motor leads, switch-
lumps and thin spots and have exceptional- boards and inside wiring where a good in- ,
insulating efficiency, due to the heavy and. sulation is required. Strong in friction,
even saturation;' They, contain the maxi- possesses high heat - retarding qualities
mum yardage per pound..
and dielectric strength.
Johns-Man vi 11 e Friction Tapes . are \ Johns-ManvilleNo. 5Friction Tape-A three-fourths, of. an inch wide and are put good grade for standard electrical work
up in standard 4-ourice and 8-ounce rolls, and other miscellaneous and domestic
wrapped in tin-foil and packed in strong uses; free from surface defects. Shows
Manila paper cartons.
little or no deterioration for a year, if
Jomanco--Gray in color', is the high- stored under proper conditions,
est grade of friction tape on the market, Johns-Manville Armature 'Tape--Made
and is recommended for permanent un- from thin, closely woven sheeting of high-
derground, subway, mines, railway signal, est quality, frictioned on one side only,
sign, wireless telegraph systems and gen- Suitable for winding armatures, field coils, eral out-door work, where the highest etc.
`Johns-Manville Friction Tapes are standard with many of the largest steam and electric railroads in the United States. These are guaranteed tapes and with the ex ception of Johns-Manville Armature Tape will be re
placed if found defective within one year from date of manufacture. Prompt shipment can be made from adequate stocks in all important cities in the United States and Canada.
241
CRMC-003605
Johns-Manville Service to Railroads
Johns-Manville Rubber Splicing Compound
ADE of Para rubber scientifically
M compounded so that it does not dry out. When applied it forms
in 4-oz. and 8-oz. rolls, wrapped in tin-foil and packed in Manila paper cartons.
Alpha Brand--A splicing compound
a homogeneous mass without the aidofothf e highest grade. It assures absolutely
heat, making watertight joints that last perfect joints, is impervious to moisture
indefinitely.
and stronger dielectrically and mechani cally than the insulation of the wire itself.
Uniform in thickness throughout -- no Will stand a test of 300 volts per mil.
lumps or thin spots -- and it has ex
Brooklyn Brand -- A good splicing
ceptional strength. Furnished in two compound recommended for low voltage
brands, Alpha and Brooklyn, %" wide, work.
Johns-Manville Asbestos Braided Tubing
This tubing is largely used for insula- It is absolutely fireproof and has been
ting conductor wires, of arc lamps and for in constant use for many years, during
covering electrical wires where, superiorwhich it has never burned out, thereby
fireproof protection is required.
causing a short circuit.
This material is extremely flexible; it
can easily be made impervious to mois
ture, and is permanently durable.
i
Some of the stees in which Braided Asbestos Tubing is made.
No.
of . Tubing
To fit . over
Wire N.o. .
Approximate Outside Approx. iN.o ..List1' Diameter Lineal Ft; Price,
of .Tutiing Per .Round Per,Round: 1
1516 1517 ' 1518 1519 1520 .1521. 1522 1523 1524 1528 1529 1530 1531 1532
' 17 B. & S. . 10B. &S. 8 B. & S. 5 B. & S. 4 B. & S. 2 B. & S. OB. &S.
: 1 >"
175 $4.00 -
100: , 4:00
-io" 85 4.0Q
t" " .65
4.00
Vs" 50 3.00
46 ' 7 3.00
1AH 22 3.00
>/" 20 3.00
Mir,"
16 3.00
T" 15 3.00
Vs" 13 3.00
1" 12 3.00
IT"
10 3.00
\yy
9 3.00
Other diameters made to order; also any form of braiding desired.
242
CRMC-003606
Johns-Manville Service to Railroads
Johns-Manville Niagrite and Asbestoment Fireproof Cable Insulation
The illustration shows the slight effect of an electric arc at a voltage of from 90 to 110 and a current of from 400 to 2000 amperes, the electrodes placed J/n" below the test piece. It was intended to reproduce the destructive action which might be expected should an arc occur in the cable adjacent to the one on which the fireproofing was being tested. The
arc was sustained for a period of two minutes. It has been estimated that the temperature at the crater was from 3500 to 4000 F., the temperature falling off slightly at the higher voltage. During the test the thermo-couple showed the temperature rise in the tested cable over 75 F. within the bounds of safety.
HE Johns-Manville Niagrite-Asbes to a thick paste, is then applied by hand
Ttoment Method of fireproofing cables has been developed to protect valu
to a thickness of approximately When dried, which takes approximately
able cable equipment from the destructifvoer,ty-eight hours under normal air condi
action of an arc occurring in adjacent con-. tions, the Asbestoment sets and becomes
ductors, It is. used, wherever cables of adamantine with age. Moisture or even
. high. potential are: exposed, . particularly immersion indefinitely has no effect on it.
in manholes where splices are located, or. It may be applied 50 Ac faster than any
where feeder cables are trained to the back other form of cable fireproofing and will
of switchboards. .
.A.
allow greater freedom in bending cables
Its components are Johns-Manville' without cracking the fireproofing than any
Niagrite and. Johns-Mariville ^ Asbesto other known form of. cable protection.
ment. Niagrite is an:.asbestos felted'ma
terial . backed with asbestos cloth, made in
the form of .a -tape, in rolls 15 feet long:
and in ail thicknesses from to
The
best standard construction is a double
layer of G" thickness. A roll of this tape
is loosened and immersed for about twenty
minutes in a solution of Johns-Manville
Asbestoment. This is a special super-re
fractory cement, chemically neutral. Both
these materials are free from ingredients
which might corrode lead cable sheathing.
When the Niagrite tape has been
thoroughly moistened with the cementing
material, it is applied directly to the cable,
being wound spirally with butted joints.
The second layer should be applied with
. It has superior thermal conductivity' so that heat, within the cable is led away more rapidly than by muslin, paper or the rubber insulation nearest the copper con ductors.
This Niagrite-Asbestoment combina tion has been tested under actual manhole conditions by some of the largest com panies in the United States. (See test.)
This is assurance that this combination will prevent communication of burnouts where cables are exposed to an arc occur ring in adjacent circuits. The resulting saving in valuable equipment and contin uity of service is well worth the moderate cost of such an installation.
joints midway between joints of the initial The nearest Johns-Manville office will
layer, which makes for greater strength. be pleased to offer further suggestions as
An outer covering of Asbestoment, mixed to cable equipment protection.
243
CRMC-003607
Johns-Manville Service to Railroads
Johns-Manville Third-Rail Covering
Special covering for the bonded fish plate joints.
Straight section for rail covering.
(As used by Philadelphia Rapid Transit Co.)
Covering of the T . rail in the' conddit ' of .the Surface.road of New York City.'
Wilgus Under-run ning third-rail cov ered with indurated
fibre covering.
Transmission rail of . the Elevated and the
New York Subway: .'.The exposed parts
covered by indurated .fibre material.
.
1 ,^QR. many years we have, supplied a cluding the maker's name; section number P weatherproof covering made of .fibre and full size, sketch of. the rail, together
and impregnated with .a high quality . with quantities and delivery desired. Pres
of : asphalt, for .enclosing the feed rail of. ent factory equipment will produce several
electric railways.
pf the more popular types, but. where
Recent specifications have called for im : special material is required, a nominal, pre sulatipn to cover the sides and top of liminary charge may be made.
power rail, the contact being from the un der side. To take care of the joints be tween rail lengths, enlarged sections have been developed which allow suffi cient room to cover the fish plates, bolts and hangers, as shown above, but material can be furnished for practically any type of installation.
Johns-Manville Third Rail Insulation is the most modern protection so far devel oped; it has ample dielectric strength; provides a complete cover, if desired; will effect large savings through protecting power rails from ice coating in the north ern latitudes; presents a most pleasing and ornamental appearance and, unlike
All inquiries sent in should include com wood covering, will withstand the ele
plete information as to use and service, in ments indefinitely.
Price on application.
244
CRMC-003608
Johns-Martville Service to Railroads
Johns-Manville Success Chemical Fire Extinguishers
Approved and labelled by the Underwriters' Laboratories, Inc.
Automatic Type
Hand-Pumped Style (Non-Freezing)
Johns-Manville Success Fire Extin guisher is made of extra heavy, cold rolled, Lake Superior copper. Starts and stops simply by reversing the position, of the extinguisher.
An effective fire-fighting apparatus that can be easily handled, operated and re charged. Throws a high pressure stream for dis tances up to 50 ft. Ex tinguishes benzine, naphtha, tar and other flames on which water has practically no effect. It is superior to others for the following reasons:
All joints are securely riveted ;and. reinforced, by heavy shoulders. of solder.;
Tested to a pressure of 350 lbs. to the square inch; ---four times .'the
Made with a standard, size bottle- andcast brass bottle holder,' instead of the flimsy brass wire .holder ordinarily used.
The Johns-Manville Success NonFreezing Fire Extinguisher will not freeze at any temperature above forty de grees below zero. It will afford unfailing protection from fire at all times, particu larly when other fire extinguishers, as well as water pipes, would be frozen up and out of commission.
Easily portable and can be operated by anyone. A pliable rubber hose makes it possible to aim the stream in any direction without moving the extinguisher.
Throws a continuous stream fifty or sixty feet. Has a 2% gallon capacity, suf ficient for most incipient fires.
Tank is made of copper, protected by a
double application of lead-tin alloy and a
coating of "Insulite," an asphaltic base,
paint. Double acting pump is made of
seamless brass tubing. Pump plunger
made of a special alloy not affected by the
solution.
.
Tested by the .Under writers' Laboratories, Inc., by being operated 73,000 strokes and remained in good working order.
Also a unique bottle stopper which regulates the flow of sulphuric acid into the bicarbonate of soda thus generating the correct amount of gas at all times. This avoids explosion--which is possible in extinguishers where total quantity of both liquids is mixed at once.
The Johns-Manville Success Fire-Ex tinguisher meets every requirement of de pendability and durability.
To operate: withdraw the metal pin holding the pump handle which releases the pump and permits im mediate use. Recharged by pouring solution through filler opening. No recharg ing necessary until contents have been discharged, as so lution will not deteriorate.
245
CRMC-003609
Johns-Manville Service to Railroads
Johns-Manville Asbestos Lead Joint Runner
Runner equipped with spring clamp.
OR making lead joints in cast-iron
Fgas and water pipes, Johns-Manville Asbestos Lead Joint Runner is the most practical device on the market. is composed of specially prepared asbestos rope, of square cross-section, having a fer rule on each end and. provided with a clamping device for fastening in place on the pipe as shown, in the above illustra tions; The rope used is solid asbestos, containing no core1 of jute br other com bustible material.
Owing to the shape of this device and its flexibility, it covers the pipe joint snug ly, so that there is no leakage of lead nor aInty unnecessary lead left protruding from the joint to be chipped off afterwards.
Being made of asbestos, it will not char or burn from contact with molten metal. The ferrules are of: such design that they cannot be pulled off. The clamp is of simple construction and practically inde structible.
ASBESTOS .RUNNERS FOR VARIOUS SIZES OF PIPE
No.
..'I 0..............Rope ./ 44 inch square, for. 2, 3 and 4 inch pipe
2 , ........... Rope ;r. 44'inch square, for' 4, 5 and 6. inch pipe
' 3 . . ..............Rope T inch square, for 6, 8: and 10 inch pipe
4 ; ........... Rope U : inch square, for 10, 12 and 14 inch pipe
- 5 . .
.. Rope :144 inch square, for 16, 18 and 20 inch pipe
6 . ............ Rope'444 inch square, for
24 inch pipe
7- . ................ Rope, 1*4 inch square, for 8 ................ Rope 1 j/j-inch square, for
48 inch pipe ; 42 inch pipe
9 ; , ........... Rope 144 inch square, for
36 inch pipe
10 . ............. Rope 144 inch square, for
30 inch pipe.
Johns -Manville
Asbestos Clothing
We are prepared to furnish Asbestos Clothing of any de scription, and in any quantity. This clothing is made up in standard clothing sizes.
The following list covers articles which will be made up according to any desired specifications:
Aprons Arm protectors Caps
Coats Gloves Gaiters
Helmets Overalls Jumpers
Leggins Mittens Shoes
246
A suit of Johns-Manville Asbestos Clothing com plete with helmet, gloves
and gaiters,
CRMC-003610
CRMC-003611
Johns-Manville Service to Railroads
How to Use Tables of Pipe Insulation Efficiencies
The efficiencies of pipe insulations vary ac cording to the size of the pipe insulated and ac cording to the temperature difference between steam in the pipe and air surrounding the pipe.
The relative values of different insulations may be determined by comparing either their effi ciencies or the heat losses through the various types of insulation.
The efficiencies furnish a means of comparing the savings effected by insulations with bare pipe losses. These latter are very large; there fore, a seemingly small difference in efficiency may represent a really large difference in heat losses.
The heat losses may be compared directly as follows:
Bare surface loss............................= 100% Efficiency' ................ .... .............. .=Percent saving
100%--% Efficiency = Loss through, insulation
expressed as a percentage of bare surface loss.
For example, an insulation which is. 90% effi
cient allows a loss of only 10% of the loss from bare surface.
EXAMPLE:--The efficiency of 2" thick AsbestoSponge Felted Sheet Insulation at 500 temperature difference is 95.44% and the efficiency of the same in sulation 3" thick is 96.85%. The difference in efficien cies is only 1.41% which seems extremely small and might lead one to believe that it would not pay to use the extra inch of thickness.
However, the loss through the 95.44% efficient insula tion is 4.56% of the loss from bare surface and the loss through the 96.85% efficient insulation is 3.15% of the loss from bare surface. The difference 4.56%--3.15% = 1.41%. Therefore, the loss through the 2" thickness is (1.41 -4--3.15=) 45% greater than the loss through the in sulation 3" in thickness.
The table on page 249 gives the total heat losses at various temperature differences on bare pipe of different sizes, and on fiat surfaces. Tables of efficiencies of the different insulations on vari ous sized pipes and on flat surfaces at various temperature differences are given following the pages describing the insulations.
Use such efficiency tables as follows:
Example
What is the efficiency of: Johns-Manville :Asbesto-Sponge Felted Pipe Insulation .2. inches thick, to be applied on a 6-inch pipe conveying steam at 200 pounds gauge -pressure through a room where temperature is'7.0 -F,,?
1. . Determine;, difference between temperature
of steam in pipe and , air surrounding pipe (see Steam-Tables, pages.249 to 252..
' Temperature of steam 200 lb. pressure 388 F. Temperature of air around pipe......: 70 F.
Difference .......................................... ..
318 F.
2. Refer to Table of Efficiencies for 2". thick
Asbesto-Sponge Felted Pipe Insulation.
Opposite pipe size (6"), you find
Efficiency for 350 F. difference.............. 92.6% for 300 F. difference............. 91.9%.
Difference for 50 ......................................
.7%
If difference for 50= .7% then for 1 difference is .7-t-50=.014%.
The difference you have (318) is 18 more than 300, so 18 x .014=.252% which, added to 91.9% (efficiency for 300)=92.15% the required effi ciency.
If you desire to find exactly how much heat, is. saved by applying this 2" insulation, proceed as follows :
1. Refer to table giving total , heat loss .in
B.t.u. per lineal foot of bare pipe .(page 249).
Opposite pipe size (6") and under. 300 differ-, enc.e you find loss is 1694.9 - B.t.u. per hour. ..Under 350 difference the loss is. 2198.7 B.t.u. Difference in loss, for the 50 difference=2198.7-- 1694.9=503.8 B.t.u. and for Is difference it is 503.8-4-50=10.07 B.t.u.
The difference you have (318) is 18 more than 300, so 18 x 10.07 = 181.3 B.t.u., which added to 1694.9=1876.2 B.t.u., the required total heat loss from 1 lineal foot of the 6" bare pipe per hour.
Having obtained the loss for bare pipe the sav ing effected by the 2" Asbesto-Sponge Felted Insulation is obtained by multiplying the total loss 1876.2 B.t.u. by the efficiency of the insula tion formerly found (92.15%) or 92.15 x 1876.2 = 1729 B.t.u. saved per lineal foot per hour.
This result may be compared with the quanti ties of heat saved by other types or thicknesses of pipe insulations which quantities may be ob tained in similar manner to the above.
248
CRMC-003612
Johns-Manville Service to Railroads
Total Heat Loss in B. t. u. Per Hour Per Lineal Foot of Bare Pipe of Different Sizes, and Per Square Foot of Flat
Surfaces, at Various Temperature Differences
(For finding losses at temperatures between those shown, the B. 1.1 Differences per Degree are given in small type between the Ma in Columns)
Temperature Differences
Pipe Sur- 50
100
150
200
250
300
350
Pipe face per
Heat Loss in B. t. u. per lineal ft. per Hour
79.2 *-6 117.3 *.90 162.3 *1.03 215.2 *1.28 279.1 1.54 355.1 1-93 451.4 *2-37
3' " .274 26.8 -64 59.0
98.6
146.8 1.11 202.1 1.33 268.5 1.3S 347.6 I,S9 442.2 z.40
2.95
.344 33.6 .Si 74.0 X.00 123.8 t-19 183.4 t.41 253.7 1.D7 337.4 1.98
2-37
3.03
3-69
i >r 15."
2"
.435 .498 .622
42.5
93.6
48.7
107.2
60.9 1.46 133.9
3.26 I.So
156.6 179.3 223.9 2-13
231.9 1.78 265.4 2.04 331.5 2.54
320.8 j.o9 367.3 2.39 458.7 2.99
425.4 2-53 487. 2-90
608.3 3-62
SSI.9 3-00
3-44 4-29
702.1 3.So
4-36 5-45
892.6
4.68
5-30 6.0Q
1126.7
2;:.~
3" 3);"
1.76 161.6
89.6
197.3
1.047 102.3 2.46 225.3
2.18 2.66 3.03
270.4 330.1 376.9 3-62
400.3 3.07 488.8 3-73 558.1 4-2S
553.9 3.01 676.3 4.41 772.2 3.04
734 .S 896.8 1024.
4-37 952.8 5-33 1163.4
6.09 1328.4
5. IO 1212.1
0.33 -.43
6.5S 1541.1 8.0S
8.03
9.S;
9-17
11.3
1945.1
4" 1.178 115.1 n -- 2S3.5
424.2
627.9 4.S2 868.8 s-t: 1152.1 6.S3 1494.6 s.13 1901.3 10.3 2417.3 12.7 3051.
4 > 1.309 127.9
281.5
470.9
697.2 5.35 964.7 0.20 1279.2 7.0i 1659.5 0.03
5" 1.456 142.2 3.42 313.1 4.21 S23.8 3.03 775.5 5*95 1073. 700 1423. S.46 1846. 20.0
n.05 52.7
14.1 15-7
3768.5
6" 1.734 169.4
371.9
623.9
923.7 7.09 1278.1 S.34 1694.9 10.1 2198.7 12.0 2797.1 15-2 3556.2 IS.6 4488.5
1066.0 S.n 1475.6 o.-.t 1956. 11.66 2539. 13.7S
17.46
21.6
8" 2.257 220.6 5-30 485.7 6.54 812.5 7.Si 1203. 9.23 1664.5 to.5 2207.3 13-1 2863.6 15.6 3642.8 19-S 4631.4 24.3
9" 2.52 246.0
542.
907. 8.72 1343. 10.34 1860. 12.t 246S. 14.7 3200. 17.4 4070. 24.0 5170. 27.3 6530.
10" 2.817 275.4
606.2 s.16 1014.1
1501.5 11.3 2077.5 13.6 2755. 16.4 3574.1 19-5
24-7
30.3
11" 3.08 300. 7.26 663. s.92 1109. 10.66 1642. 12.6 2272. 14.76 3010. >7-9 390S. 21.3
20.9
33-3
12" 3.34 326. 14"o. d. 3.66 16"o. c. 4.19 408.
719. 786.
`>.S4 901.
12.2
1203. 1318.
1510.
,, 12.04 Uo
1780. 1950. 2233.
13.7 13.0 17.2
2465. 2700. 3095.
16.02 3266. 17 05 3580. 20.1 4100.
19.4
21.3 44-4
4235. 4645.
23-1 2 t.? ?s.g
5390. 6/65.
29.2
31.9 3t-3
6850. 30*0 39-5 45-2
8650.
Surfaces.
97.5 2-35 215.2 ' 2.f)0 360.0 7.an
(. 1.950
2.1S2
2.400 .
533.0 2.665
u. per sq. ft. per Hour
4-to 737.8 4
978.0 5.S3
269.4 6.80 1614.0
per degree temperature difference per Hour
2.951
3.260
2" Pit e, 235 5 Temp. Difference. 235 r -- 200 " = 35: 3 5 x 2.S4 (B. . u. per degree) =88.9 B. t. 1 . 331. -r88.9 = 420 4 : B. t u. loss at 235* Temp. difference.
Steam Table
Reprinted from Marks '& Davis' Steam Tables and Diagrams, by permission of the publishers, Longmans, Qreen & Company V
; Press.
lbs. -
`p '
1-
.0 .3 4.3
S
6
8 9 10
11 12
14 14.7
15 16 17 18 19
9.3 24
Deg: T. t
101,83 126.15 T41.52
162.28
170.06 176.85 182.86 188.'27 193.22
197.75 201.96 205J87 209.55 212.00
213.0 216.3 219.4 222.4 225.2
228.0 230.6 233.1 235.S 237.8
Press. Atmos*
' ----
0.068 0.136 0.204 0.272 0.340
'Sp.Vol. Density" cu. ft.- lbs: per
.-per !b. CU.'ft . v or s ' . v.
333.0
173.5 118.5
90.5 73:33
0.00300 0.00576 0.00845 0;01107
0.01364
' Heat of the liquid h or q
69.8 94.0 109.4 120.9 130.1
0.408 0.476 0.544 0.612 0.680
61.89 53.56
' 47.27 42.36 38.38
0.01616 0.01867 0:02 US 0.02261 0.02606
137.9 144.7 150.8 156.2 161.1
0.748 0.816 0.885 0.953 1.000
35.10 32.36 30.03 28.02
26.79
0.02849 0.03090 0.03330 0.03569 0.03732
16S.7 169.9 173.8 177.5 180.0
1.021
1.089 1.157 1.225 1.293
26.27 24.79 23.38
22.16 21.07
0.03806 0.04042
0.04277 0.04512
0.04746
181.0 184.4
187.5 190.5 193.4
1.361
1.429 1.497 1.S65 1.633
20.08 19.18 18.37 17.62 16.93
0.04980 0.05213 0.05445 0.05676 0.05907
196.1 198.8 201.3 203.8 206.1
Latent heat of evap. L or r
1034.6' 1021.0 1012.3 100S.7 1000.3
995.8 991.8 988.2 98S.0 982.0
979.2 976.6 974.2 971.9 970.4
969.7 967.6 96S.6 963.7 961.8
960.0 958.3 956.7 9S5.1 953.S
Total heat of steam
H:
1104.4 1115.0 1121.6 1126.5 1130.5
1133.7 1136.5 1139.0 1141.1 1143.1
1144.9 1146.S 1146.0 1149.4 1150.4
1150.7 1152.0 1153.1 1154.2 1155.2
1156.2 11S7.1 1158.0 1158.8 1159.6
Internal Energy B.t.u. ....
Evap. Steam' 1 or P
Entropy
Water . tsvap. Steam n or 6 L/-T or r,,.T Nor#
972.9 ' .956.7 946.4 938.6 932.4
1042.7
0.1327
1050.7 0.1749
10SS.8
0.2008
1059.5 . . .0.2198
1062.5 . 0.2348
1,8427 1.7431 1.6840 1.6416 1,6084
1.9754 1.9180 1.8848 1.8614 1.8432
Gauge Press lbs.
927.0 922.4 .918.2 914.4
910.9
1064.9 1067.1 1069.0 1070.5 1072.0
0.2471 0.2579 0.2673 0:2756 0.2832
1.5814 1.5S82 1.5380 1.5202 1.5042
1.828S 1.8161 1.8053 1.7958 1.7874
907.8 904.8 902.0 899.3 897.6
1073.4 1074.7 1075.8 1076.8 1077.5
0.2902 0.2967 . 0.3025 0.3081
0.3118
1.4895 1.4760 1.4639 1.4523 1.4447
1.7797 1.7727 1.7664 1.7604 1.7565
.0
896.8 894.4 892.1 889.9
887.8
1077.8 1J78.7 1079.6 1080.4 1081.1
0.3133 0.3183 0.3229 0,3273 0.33 IS
1.4416 1.4311 1.4215
1.4127 1.404S
1.7549 1.7494 1.7444 1.7400
1.7360
.3 1.3 2.3 3.3 4.3
885.8 663.9 882.0 880.2 878.5
1081.9 1082.6 1083.2
1083.9 1084.5
0.3355 0.3393 0.3430
0.3465 0.3499
1.3965 1.3887 1.3811 1.3739 1.3670
1.7320 1.7280
1.7241 1.7204 1.7169
5.3 63
7.3 8.3 9.3
' 1 atmo (standard atmosphere) = 760 turns, of Hg. by def. = 29.921 ins. of Hg. = 14.696 lbs. per sq. in.
T * =t` +459.6; J =777.S ft. lbs. per B.t.u. Hog = 2.89 071,; A = >/j = 1.286 XI0-1; 144 A =0.1852 (Jog =1.26 7641-
NOTE.--The gauge pressures arc put in only for your guidance in making quick estimates of conditions, Wherever very accurate computations ure to be made, find out the atmospheric pressure at vour altitude and add this to the gauge pressure ond use the resulting abvu/ure pressure in the table.
249
CRMC-003613
Johns-Manville Service to Railroads
Steam Table
(Continued)
Press.
Vos.
10.3 11.3 J2.3 13.3 14.3
Temp. Press.
Sp.Vol. Density cu. ft. lbs. per
Heat of the
Latent Total Internal Energy
heat of heat of
B.t.u.
Entropy
Gauge
lbs. Deg. F Atmos*
cu. ft
liquid
evap. steam Evap. Steam
Water Evap. Steam Press
P
t
---*
v or 5
W
horq L or r
H
1 or p
E
n or 0 L/T or r/T R Or lbs.
25
240.1
1.701
16.30 0.0614
208.4
9S2.0 1160.4 876.8 1085.1
0.3532 1.3604 3.7136
10.3
26
242.2
1.769
15 72 0.0636
210.6
950.6 1161.2 875.1 1085.6
0.3564 1.3542 1.7106
11.3
27
244.4
1.837
15.18 0.0659
212.7
949.2 1161.9 873.S 1086.2
0.3594 1.3483 1.7077
12 3
28
246.4
1.905
14.67 0.0682
214.8
947.8 1162.6 872.0 1086.7
0.3623 1.3425 1.7048
13.3
29
248.4
1.973
14.19 0.0705
216.8
946-4 1163.2 870.5 1087.2
0.3652 1.3367 1.7019
14.3
1S.3 36.3 17.3 18.3
19.3
30
250.3
2.041
13.74 0.0728
218.8
945.1 1163.9 869.0 1087.7
0.3680 1.3311 1.6991
1S.3
252.2
2.109
13.32 0.0751
220.7
943.8 1164.5 867.6 1088.2
Q.3707 1.3257 1,6964
16.3
32
254.1
2.178
12.93 0.0773
222.6
942.5 1165.1 866.2 1066.6
0.3733 1.3205 1.6938
17.3
33
255.8
2.246
12.57 0.0795
224.4
941.3 116S.7 864.8 1089.1
0.3759 1.3155 1.6914
18.3
34
257.6
2.314
12.22 0.0818
226.2
940.1 1166.3 863.4 1089.5
0.3784 1.3107 1.6891
19.3
20.3 21.3 22.3 23.3 24.3
35
259.3
2.382
11.89 0.0841
217.9
938.9 1166.6 862.1 1089.9
0.3808 1.3060 1.6868
20.3
36
261.0
2.450
11.58 0.0863
229.6
937.7 1167.3 860.8 1090.3
0.3832 1.3014 1.6846
21.3
262.6
2.518
11.29 0.0886
231.3
936.6 1167.8 859.S 1090.7
0.3855 1.2969 1.6824
22.3
38
264.2
2.S86
11.01 0.0908
232.9
935.5 1168.4 858.3 1091.0
0.3877 1.2925 1.6802
23.3
39
26S.8
2.6S4
10.74 0.0931
234.5
934.4 1168.9 857.1 1091.4
0.3899 1.2882 1.6781
24.3
25.3 26.3
29.3
40
267.3
2.722
10.49 0.0953
236.1
933.3 1169.4 855.9 1091.8
0.3920 1.2841 1.6761
25.3
41
268.7
2.790
10.2S 0.09*6
237.6
932.2 1169.8 854.7 1092.2
0.3941 1.2800 1.6741
26.3
270.2
2.858
10.02 0.0998
239.1
931.2 1170.3 853.6 1092.5
0.3962 1.2759 1.6721
27.3
271.7
2.926
9.80 0.1020
240.5
930.2 1170.7 852.4 1092.8
0.3982 1.2720 1.6702
28.3
44
273.1
2.994
9.59 0.1043
242.0
929.2 1171.2 851.3 1093.2
0.4002 1.2681 1.6683
29.3
30.3 31.3 32.1 33.3 34.3
45
274.5
3.062
9.39 0.1065
243.4
928.2 1171.6 850.3 1093.5
0.4021 1.2644 1.6665
30.3
46
27S.B
3.130
9.20 0.1087
244.8
927.2 1172.0 849.2 1093.8
0.4040 1.2607 1.6647
31.3
47
277.2
3.198
9.02 0.1109
246.1
926.3 1172.4 848.1 1094.1
0.4059 1.2S71 1.6630
32.3
48
278.5
3.266
8.84 0.1131
247.5
925.3 1172.8 847.1 1094.4
0.4077 1.2536 1.6613
33.3
49
279.8
3.334
8.67 0.1153
248.8
924.4 1173.2 846.1 1094.7
0.4095 1.2502 1.6597
34.3
35.3 . 36.3 .
37.3, . 38.3
39.3
50 . 51 52 53 54
281.0 282.3 283.5 284.7 . 285.9
3.402 3.470 3.538 3.606 3.674
8.51 8.35 8.20 8.05 . 7,91
0.1175 0.3197 0.1219 0.1241
,0.1263
250.1 251.4 2S2.6
253.9
2S5.1
923.5 922.6
921.7 920.8 919.9
1173.6 1174.0 1174.3 1174.7 1175.0
843.0 844.0 843.1 842.1
841.1 .
1095.0 1095.3 5095.5 1095.8 1096.1
0.4113 0.4130 0.4147 0.4164 0.4180
1.2468 1.2435 1.2402 1.2370 1.2339
1.6581 3.6565
1.6549 1.6534 1.6519
35.3 36.3 37.3 38.3 39.3
40.3 4i.3
:
43.3 . 44.3 ,
55 56 57. 58 S9.
287.1 . 288.2
289.4 290.5 291.6
,3.742 3.810 3.878 3.947 4.015
7.78 7.65 .7:52 7.40 7.28
0.1285 0.1307 0.1329 0:i350 04372
256.3 257.5 2S8.7 259-8 261.0
919-0 916.2 917-4 916.5 915.7
1175.4 1175.7 1176:0 1176.4
1176.7
840.2
839.3 838.3
837.4 836.S
1096.3 1096.6 1096.8 1097.1
1097.3
0.4196 0.4212 0:4227 0.4242
0.4257
1.2309'
1.2278 ' 1.2248 1.2218
1.2189
1.6505 1.6490 1.6475 1.6460
1.6446
40.3 41.3
' 42.3 43.3 44.3
45.3, 46.3 :.
49.3
.60 61
64 ;
. .292,7 293.8 294.9 295.9 .2.97.0
4.083 4.151 4.219 4.287 ,4.355
.. 7.17 7.06 6:95 6:85 6.75
0.1394 0.1416 0.1438 ,0.1460 0.1482
262.1 263.2 264.3 265.4 .266.4
. 914.9
914.1 : 913.3 . 912.5 911.8
1177.0 1177.3 1177.6 1177.9 1178.2
835.6 834.8 833.9 833.1 832.2
1097.6 1097.8 IQ98.0 1098.2
1098.4
0.4272 0.4287 0.4302 0.4316 0.43,30
1.2160 1.2132 1.2104 1.2077 1.2050
1.6432
1.6419 1.6406 1.6393 .1.6380
4S.3 46.3 47.3 48.3 49.3
50.3 SI.3 ' 52.3.'
S3.3 i. 54.3
6S 66- : 67 68 69
;29fl.0,.
i299.Q\ .300:0 ::3'oi;o 302-0.
,4.423
4.491 4.S59 . 4i627 .4,695
6.65 0..1S03 ,6.56 0.1525
6.47 . 0.1547 648 0.1569 6129 O.I590
.
.267.5 268.5 ,269.6
270.6 ,271.6
911.0 . 1178.5 . 910.2 .1)78.8 ; 909.5 1179.0
908.7 1179.3
908.0 1179.6
831.4 830:5 829.7 828.9 828.1
1098.7 1098.9'. 1099.1 1099.3 1099.5 :
0.4344 0.4358 0.4371 0.4385
0.4398
1.2024 ' 1.6368
1.1998 . 1.6345 . L1972 1.6323 1.1946 1,6311
1.1921 . 1.631.9
. 50.3 51.3 52.3 53.3 54.3
55.3 ' 59,3 '.
70 74. -.
302.9
.4.763
" 303.9
4:831
304.8
-4:899
.305.8. .4.967
- 306.7 ' 5.035
6.20 ' 6.12 : "6.04
5.96
i 5.89
0,1612 0.1634 Q.16S6 ,0.1678 0.1699
.2,72.6 ,273.6 .274.5 275.S 276.5
907.2 906.5 . 90S-8
90S! 904.4
,11.79.8 1180.1 1180.4 1180.6 1180.9
827.3.826.5 825.8
825:0 . 824.2
1099.7 0.4411
1099.9
0.4424
1100.1
0.4437
1100.3 0.4449
1100.5 . 0.4462
1.1896L1872. 1.1848 1.182S 1.1801
1.6307. 1.6296 1.6285 1.6274
1.6263
S5.3 56.3 57.3 58.3 S9.3
60.3 61.3
64.3
,76. '
.78 . 79
.'307.6 308,5
309-4 310.3 311.2
5.103 5.171 5:239 5.307 5.375
5.81 ' -5.74 ' 5.67
5.60 5.54
0.1721 0.1743 0:i764 0.1786 0.1808
277.4
.278.3 ,279.3 , 280.2
281.1
. 903.7 903-0 902.3 901.7 901.0
1181.1 1181.4 1181.6
1181.8 1182.1
823.5
822.7 822.0
821.3 820.6
1100:6
1100.8 1101.0 1101.2 1101.4
0.44 74 - 0.448/
0.4499 0.4S11 0.4523
1.1778 1.1755 1.1732 1.1710 1.1687
1.6252 1.6242 1.6231 1.6221 1.6210
60.3 61.3 62.3 63.3 64.3
65.3 66.3 67.3 68.3 69.3 ,
80
312.0
5.444
S.47 0.1829
282.0
900.3 1182.3 819.8 1101.6
0.4535 1.1665 1.6200
65.3
81
,312.9
5.S12
,5.41 0.1851
282.9
899.7 1182.5 819.1 \ 101.7
0.4546 1.1644 1.6190
.82
313.8
5.580
5.34 0.1873
283.8
899.0 1182.8 818.4 1101.9
0.4557 1.1623 1.6180
67.3
83
314.6
5.648
5.28 0.1894
284.6
898.4 1183.0 817.7 1102.1
0.4568 1.1602 1.6170
68.3
84
315.4
,5.716
5.22 0.1915
285.5
897.7 1183.2 857.0 1102.2
0.4579 1.1581 1.6160
69.3
70.3
65
3V6.3
5.784
S.16 0.1937
286.3
897.1 1183.4 816.3 1102.4
0.4590 1.1561 1.6151
70.3
71.3 .
86
317.1
5.852
5.10 0.1959
287.2
896.4 1183.6 815.6 1102.6
0.4601 1.1S40 1.6141
71.3
72.3
87
317.9
5-920
5.05 0.1980
288.0
895.8 1183.8 815.0 1102.7
0.4612 1.1520 1.6132
72.3
73.3
88
318.7
5.988
5.00 0.2001
288.9 . 895.2 1184.0 814.3 1102.9
0.4623 1.1500 1.6123
73.3
74.3
89
319.5
6.056
4.94 0.2023
289.7
894.6 1184.2 613.6 1103.0
0.4633 1.1481 1.6114
74.3
7S.3
76.3 77.3 78.3
79.3
90
320.3
6.124
4.89 0.2044
290.5
893.9 1184.4 813-0 1103.2
0.4644 1.1461 1.610S
7S.3
91
321.1
6.192
4.84 0.2065
291.3
893.3 1184.6 812.3 1103.3
0.4654 1.1442 1.6096
92
321.8
6.260
4.79 0.2087
292.1
892.7 1184.8 811.7 1103.5
0.4664 1.1423 1.6087
93
322.6
6.328
4.74 0.2109
292.9
892.1 1185.0 8)1.0 1103.6
0.4674 1.1404 1.6078
94
323.4
6.396
4.69 0.2130
293.7
891.5 1185.2 810.4 1103.8
0.4684 1.1385 1.6069
80.3 81.3
82.3 83.3 84.3
9S
324.1
6.464
4.65 0.2151
294.5
890.9 1185.4 809.7 1103.9
0.4694 1.1367 1.6061
80.3
96
324.9
6.532
4.60 0.2172
295.3
890.3 1185.6 809.1 1104.1
0.4704 1.1348 1.6052
97
325.6
6.600
4.56 0.2193
296.1
889.7 1185.8 808.5 1104.2
0.4714 1.1330 1.6044
82.3
98
326.4
6.668
4.51 0.221S
296.8
889.2 1186.0 807.9 1104.4
0.4724 1.1312 1.6036
83.3
99
327.1
6.736
4.47 0.2237
297.6
886.6 1186.2 807.2 1104.S
0.4733 1.1295 1.6028
84.3
1 atmo {standard atmosphere) = 760 mmt. of He. by def. = 19.971 ins. of Kg.13 14.696 lbs. per sq. in, T* = t * + 459.6; J =777.5 ft. lbs. per B.t.u. (log = 2.89 0711; A = /j =1.286 X10-1; 144 A =0.18S2 (log = 1.26 664[.
NOTE.--The gauge pressures are put in only for your guidance in making quick estimates of conditions. Wherever very accurate com putations are to be made, find out the atmospheric pressure at your Altitude and add this to the gauge pressure and use the resulting ab$olu to pressure ia the table.
250 CRMC-003614
Johns-Manville Service to Railroads
Steam Table
(Continued)
Gauge Press.
Absol. Press.
lbs.
89.3
104
94.3
109
99.3
114
106.3 114.3
123 129
124.3
139
134.3
149
144.3' '
159
148,3; 154.3 169
164.3
179
174.3 184.3
189 191'
199
Temp. Press. Deg. F, Atmos*
330.7
7.08
334.1
7.42
337.4
7.76
343.2
8.37
346.8
8.78
' 352.S
9.46
3S7.9 : ,'359;0
10.14
363.1
10.82
36e:o ' . 11.50'-
-372.7 ,.12:i8
377.2 381:4
12.86 . 13.00
13:40 13.54
Sp.Vol Density cu. ft. lbs. per per lb. cu. ft v or s i/v
4.268 0.2343
Heat of the liquid h or q
298.3 299.1 299.8 300.6 301.3
Latent heat of evap. L or r
886.0 887.4 866.9 886.3 885.8
Total
steam H
1166.3 1186.5 1186.7 1186.9 1187.0
Internal Energy
Evap. 1 or P
606.6 806.0 805.4 804.8 804.2
Steam E
1104.6 1104.8 1104.9 1105.0 1105.1
Entropy
Water Evap. Steam n or 6 L, T or r/T Nor* 0.4743 1.1277 1.6020
Gauge Press
lbs.
85.3 86.3
0.2386 4.082 0.2450
302.0 302.7 303.4 304.1 304.8
885.2
884.7 884.1 883.6 883.0
1187.2 1187.4 1187.5 1187.7 1187.9
803.6 803.0
802.5 801.9 801.3
1105.3 110S.4
0.4789 0.4798
1.1191
1.5980
90.3
3.912 0.2556
30S.S 306.2
306.9 307.6 308.3
882.5
881.9 881.4 880.9 880.4
1188.0 1188.2
1188.4 1188.5
1188.7
800.7 800.2 799.6 799.0 798.S
1105.9 1106.0 1106.2
1106.3 1106.4
0.4834 1.1108 1.5942 0.4860
9S.3
3.639 0.7480 3.478 0.2875
309.0 310.3 311.6 313.0 314.3
315.5 316.6 318.0
879.8 878.8 877.8 876.7 87S.7
874.7 873.8 872.8
1188.8 1189.1 1189.4 1189.7 1190.0
1190.3 1190.S 1190.8
797.9 796.8 795.7 794.7 793.6
792.6 791.5 790.S
1106.5 1106.8 1107.0 1110.2 1107.4
1107.7 1107.9 1108.1
0.4877 0.4894
1.1030
1.5907
100.3
0.4959 0.4974
1.0880
1.5839
110.3
3.241 0.3086
319.3 320.5 321.7 322.8 324.0
871.8 870.9 869.9 . 869.0 868.1
1191.1 1191.3 1191.6 1191.8 1192.1
789-S 788.5 787.5 786.S . 785.5
1108.3 1108.5 1108.7 1108.9 1109.1
O.SOOS 1-0796 1.5801 116.3
3.033
0:3129
0,3171 0:3213 0:32SS 0:3297
325.2 326.3 327.4
328.6 -329.7
867.2 866.3 865.4 864.5 863.6
1192.3 1192.6 1192.8 1193.0
1193.3
784.6 783.6 782.7 781:7 780.8
1109.3 1109.5
1109.6
0.5079 1.0662 1.5741 126.3
2.861 0.3508
330.8 331.9 ' 332.9 334.0 33S.1
862.7 861.8 861.0 860.1 859.3
1193.5 1193.7 1194.0 1194.2
1194.4
779.9 779.0
778.1 777.2
776.3
1110.2 1110.4 1110.S 1110.7 1110.8
0.5148 0.5162
. 0.5175 0.5188 0.5201
1.0538 1.0513 1:0489
.1.0443
1.5686
136.3
336.2
- 337.2
' 338.2
0,3675
339.2
> 2.690 0.3717 : 340.2
8S8.4 8S7.6 6S6.8 8S5.9 855.1
. 1194.6 1194.8 1195.0 1195.2
: 1195.4
775.4 774.S. 773.6 . 772.8
771.9
1111.0 1111.2 > 1111.3 . 1111.4
. 1111.6
0.5214 v 0.5226 . 0^5239
0.5251
0.5263,
1.0420 -1,0398
1.0354 1.0332
1.5634
146.3 15,4.3
2.602 . 2.547
0.3759 ; 341.2 0:3801. ' -342.2 '0.-3843 . 343.2 0.-3865 1 344.2 0:3927 '345.2
854.3 853.S 852.7 851.9 8S1.2
: 1195.5 771.1 1111.7 1195.7 . 770.2 . 1111.9
, 1195.9 .7.69.4 . 1112.0 1196.1 768.6 . 1112.2
: 1196-3. : 767.8 1112.4 ,
0.5275 1.0311
. 0.5287 . 1,0289
0.5299 0.5311 - 1.0246
.0-.5322 1.0225
1.S586 156.3
1.5567. , 160.3 162.3
1.5547 -164.3
2.520 2.418
0.3969 0:4010 0:4052 '0.4094 0.4136
- 346.1 347.1
' 348.0 1 349.0 .349.9
850.4 849.6 848.8 848.0
.847.3
1196.5 767.0 1196.7 766.2 1196.8 765-4
1197.0 764.6
' 1197.2 . 763.8
1112.5 1112.6 lli2.8
1112.9 1113.0
0.5334 1.0205 ' 0.5345 . .1.0185
0.S356 1-.0164 .0.5367 1.0144 0.5378 ' 1.0124
1.5539 1.5530 1.5520 1.5511 1.5502
166.3 '168.3 170.3 . 172.3 174.3
2.393 2.369 2.346 2.323 2.301
0.4178 0.4220 0.4262 0.4304 0.4346
350.8
351.7 352.7 353.6 ' 354.4
846.5 845.8 845.0
844.3 843.6
1197.3 1197.S 1197.7 1197.8
' 1198.0
763.0 762.2 761.4
760.7 759.9
1113.2 1113.3 1113.4 1113.6 1113.7
0.S389 0.5400 . 0.5410 0.5421 0.5431
1.010S
1.0085 . 1.0066
1.0047 1.0029
1.S494
1.5476 1.5468 1.5460
176.3 184.3
194.3
201
203
205 384.0
207
384.8
14.08
209
385.6
14.22
2.279 2.2S8
2.237 2.217
2.197
0.439 0.443 0.447 0.4S1 0.4SS
355.3 356.2
357.1 358.0
358.8
842.8 842.1 841.4 840.6
639.9
1198.2 1198.3
1198.S 1198.6 1198.8
759.2
758.4 7S7.6 7S6.9 756.2
1113.8
1113.9 1114.0 1114.2
1114.3
0.5442 0.5452
O.S463 0.5473 0.5483
1.0010 0.9992
0.9973 0.99S5
0.9937
1.5452 1.5444 1.S436 1.S428 1.5420
186.3 188.3 190.3 192.3 194.3
196.3 198.3 200.3
204.3
208.3 210.3 212.3 214.3
211
386.4
14.36
213
387.2
14.49
215
388.0
14:63
217
388.8
14.77
219
389.S
14.90
221
390.3
15.04
223
391.1
15.17
225
391.9
1S.31
227
392.6
15.45
229
393.4
IS.56
2.177 2.158 2.138 2.118 2.100
0.459 0.463 0.468 0.472 0.476
2.082 2.064 2.046 2.030 2.013
0.480 0.485 0.489 0.493
0.497
3S9.6 360.5 361.4 362.2 363.0
363.8 364.6 365.5 366.3 367.1
839.3 838.6 837.9 837.2 836.5
835.8 835.1 834.4 833.8 833.1
1198.9 1199.1 1199.2 1199.4 1199.5
1199-6 1199.8 1199.9 1200.0 1200.2
75S.S 754.7 754.0 753.3 752.6
751.9 751.2 750.5 749.8 749.1
1114.4 1114.5 1114.6 1114.7 1114.8
111S.0 1115.1 1115-2 1115.3 1115.4
0.5493 0.5503 0.5513 0.SS23 0.5533
0.S543 0.5553 0.5562 0.5572 0.5582
0.9920 0.9902 0.988S 0.9867 0.9850
0.9833 0.9816 0.9799 0.9783 0.9766
1.5413 1.540S 1.5398 1.5390 1.5383
1.5376 1.S369 1.5361 1.S3S5 1.5348
196.3 198.3 200.3 202.3 204.3
206.3 208.3 210.3 212.3 214.3
*1 atmo (standard atmosphere) =760 mms. of He- by definition =29-921 ins. of Hg. = 14.696 lbs. per sq. in. T" =t *+459.6; J =777.5 ft. lbs. per B.t.u. [log =2.89 071J: A ='/j =1.286 X10-J; 144 A =0.1852 Jlog =1.26 664). NOTE.---The gauge pressures are put in only for your guidance in making quick estimates of conditions. Wherever very accurate com putations are to be made, find out the atmospheric pressure at your altitude and add this to the gauge pressure and use the resulting absolute
pressure in the table.
251
CRMC-003615
Johns-Manville Service to Railroads
Steam Table --(Continued)
Gauge Preia.
lb*.
216.3 218.3 120.3 222.3 224.3
Absol. Press. lbs.
x>
231 233 235 237 239
Temp. Deg. P.
t
394.1 394.9 395.6 396.4 397.1
Press. Atmos*
---*
35.72 15.86 15.99 16.13 16.26
Sp.Vol. cu. ft. per lb. v or s
1.996 1.980 1.964 1.948 1.932
Density lbs. per
cu. ft */v
0.501 0.505 0.509 0.513 0.518
Heat of the liquid h orq
367.9 368.7 369.4 370.2 371.0
Latent heat of evap. L or r
832.4 831.8 831.1 830.4 829.8
Total heat of steam
H
1200.3 1200.4 1200.6 1200.7 1200.8
Internal Energy
B.t.u.
Evap. Steam
1 or p
E
748.4 747.7 747.0 746.4 745.7
1115.5 1115.6 1115.7 1115.8
1115.9
Entropy
Water Evap. Steam no r 0 L/Tort/T Note
O.S591 0.S6C1
0.5610 Q.S619 0.5629
0.9750
0.9733 0.9717 0.9*00 0.9684
1.5341 1.5334 1.5327
1.5319 1.5313
Gauge Press
lbs.
216.3 218.3 220.3 221.3 224.3
226.3 228.3 230.3 232.3 234.3
241
397.8
16.40
243
398.5
16.53
245
399.3
16.67
247
400.0
16.81
249
400.7
16.94
1.917 1.902
1.887 1.872
1.857
0.522
0.526 0.530 0.534 0.538
371.8
372.6 373.3 374.1 374.8
829.2 828.5 827.9 .827.2
826.6
1200.9
1201.1 1201.2 1201.3
1201.4
74S.0 744.4 743.7 743.0
742.4
1116.0 1116.1 1116.2 1116.3 1116.4
0.5638 0.5647 0.5655 0.5663 0.5672
0.9668 0.96S3 0.9638
0.9623 0.9607
1.5306 1.5300
1.5293 1.5286 1.5279
226.3 228.3 2303 23 2J 234.3
235.3
250
401.1
17.01
237.3
252
401.8
17.15
239.3
254
402.4
17.28
241.3
256
403.1
17.42
243.3
258
403.8
17.56
1.850 1.836 1.822 1.839 1.795
0.541 0.545
0.549 0.553
0.557
375.2 376.0 376.7 377.5 378.2
826.3 82S.6 825.0
824.4 823.7
1201.5 1201.6 1201.7 1201.8
1201.9
742.0 741.4 740.8 740.1 739.5
1116.4 1116.5 1116.6
1116.7 1116.8
0.5676 0.5685
0.5694 0.5702 0.5711
0.9600 0.9584 0.9569 0.95S4
0.9539
1.5276 1.5269 1.5263 1.5256 1.5250
235.3 237.3 239.3 241.3 243.3
245.3 247.3 249.3 2S1.3
253.3
260
404.5
17.69
262
405.2
17.83
264
405,9
17.96
266
406.6
18.10
268
407.2
18.24
1.782 1.769 1.756
1.743 1.731
0.561
0.565 0.S69
0.574 0,578
378.9 379.6 380.4 381.1
381.6
823.1 822.5 821.9 821.3
820.7
1202.1 1202.2 1202.3 1202.4 1202.S
738.9
738.2 737.6 737.0 736.4
1116.9 1117.0 1117.1 1117.2 1117.2
0.5719 0.5727 0.5735 0.5744 0.5752
0-9525 0.9511 0.9497 0.9482 0.9468
1.5244 1.5238 1.5232 1.5226 1.S220
245.3 247.3 249.3 251.3 253.3
255.3
270
407.9
18.37
257.3
272
408.6
18.SI
259.3
274
409.2
18.64
261.3
276
409.9
18.78
263.3
278
410.5
18.92
1.718
1.705 1.693 1.681 1.669
0.582 0,587 0.591
O.S95 0.599
382.5 383.2
383.9 334.6 385.3
820.1 819.5 816.9 818.3
817.7
1202.6 1202.7 1202.8 1202.9 1203.0
735.8 735.1 734.5 733.9 733.3
1117.3 1117.4 1117.S 1117.6 1117.6
0.5760
0.5768 0.5776 0,5784 0.5792
0.9454
0.9440 0.9426 0-9412
0.9398
1.5214 1.5 208 1,5202
1.5196 1.5190
255.3 257.3
2S4.3 261.3 263.3
365.3 267.3 269.3
271.3 273.3
280 282 284 286 288
411.2 411.8 412.4 413.1
413.7
19.05 19.19 19.32 19.46 19.60
1.658 1.646 1.635 1.624 1.613
0.603 0.608 0.612 0.616 0.620
386.0 386.7 387.4 388.1
388.7
817.1
816.5 815.9 815.4 814.8
1203.1 1203.2 1203.3 1203.4 1203.5
732.7 732.1 731.5
730.9 730.3
1117.7 1117.8 1117.9 1118.0 1118.1
0.5800 0.58QS 0.5816 0.S824 0.5832
0.9385 0.9371 0 9357 0.9344
0.9330
1.5185 1.51*9 1.5173 1.5168 1.5162
265.3
267.3 269.3 271.3 273.3
275.3 277.3
279.3 281.3 ,
283.3
290 292
294 296 298
.
414.4415.0 4IS.6 416.2.
- 416.8
19.73 19.87 30.01
20.14 20.28
1/602
1.591 1.581
1.571 1.561
0.624 0.629 0.633 0.637 0.641 .
389.4 390.1
390,8 391.4 392.1
814.2 813.6
812.5 811.9
1203.6 1203.7 1203.8
1204.0
729.7 729.2 728.6 728-0 .. 727.4
1118.1 1118.2 1118.3 1118.4
1118.4
-
0.S840
0.5848 0.5856 0.5863 0.S871
0.9316 0.9302 0.9289 0.9276 0.9263
1.5156 1.5150 1.5143
1.5139 1.5134
275.3 277.3 279.3
281.3 283.3
285.3 295.3 .305.3 " 3SS.3.
375.3--.
300 310 320 370 390
.
` 417.5 420.5
423.4 - 437.2
; 442.3- .
20.41 21.09 21.78
25.18 26.54
' 1.S51 1.S02
1.456 . 1.264
1.200
0.645 0.666 0.687 0.791
0.833
392.7
811.3 1204.1
395.9.
1204.S
399.V
1204.9
4J4.0 . , 792:8. - . 1206.8
419.5 , 787.9 1207.4
. 726.8 *24.0 721.2 708-2 . 703-3 ..
1118.5 1118.9 1119.21120.8 1121.4
0.5878
0.5915 0.59S1 0.6116 0.6178
0.9251
0.9187 0.9125 0.8S40
0.8737
1.5129 1.5102 1.5076 1.4956
1.4915 ,
285.3 295.3 305.3 355.3
375.2
385.3 405.3-- 455.3- .S10.3 . .
560.3". S8S.3V-
400 420
470 525 575 600
444.7 .449.6 460.9 472.3 -.481.9
486.4
.
27.22 28.58 31.98 3,5.72 39.13: 40.83
1.17 .1.11 -0=99 0.89 0.81 0.78
0.86. 0.90 1.01 1.12 . 1.24" 1.28
422. 427. 440., 453. : 464. -
469. 1
786. 780. ' 769.
747. 742.
1208.
1208. 1209. 1210.. 1211.
1211.
701. 696. 685. 673. 663. 658.
'
1122. . 1122. 1123. 1124. 1125. 1125.
, , .
0.621 0.627 . 0.640-' 0.654 ; 0.664 0.670
0.868 0.858 0:835 0.813 0.794 0.784
1.489 1.485 1.475 1.467 1.458 1.454
385-3 405.3 455.3 510.3
560.3 585.3
*i atmo (standard atmosphere} = 760
Hg. by definition.=29 921 ins. of Hg. =14.696 IBs; per sq. in. 1
. , T-? =.t *rf4S9.6;. J;= 777.5 ft. lbs. per B.t.u. [log =2.89 071J; A = '/j - 1.286X1.0-3: 144 A =0.1852 (log =1.25 764J. .
NOTE.---The gauge pressures are put in only for youc guidance in malting quick estimates of conditions. Wherever very accurate ccm-
putalipns.are to be made, find, out the atmospheric pressure-at your alti: ude and add this to the gauge pressure and use: the resulting, absolute
pressure in:the table., .
.'
Table showing Loss due to Steam-leakage
SIZE OF
.AIR;
-;;r;| :........
! STEAM
' - WATER.
OPENING Number of Cu. Ft. - Total Cost of Number of'Pounds ' Total Cost of Number: of Gals.' Total Cost of
-Wasted/, p,er; Mo. Waste per Mo.
Wasted per Mo. Waste per Mo.- .-Wasted.per Mo. Waste per Mo. @
100 lbs. -Pressure 10c. per M. Cu. Ft. 100 lbs. Pressure @ 60c. per M. lbs. 40 lbs. Pressure 15; 3c. per N3. Gals.
17,798,400
$1,779.84
305,000
$483.00 . . 1,231,000. 1' ' i
$192.00
V
9,979,200
997.92
460,000
276.00
692,400
108.00
V
4,449,600
444.96
303,000
121.80
307,700 '
48.00
'w*
1,114,560 278,640
111.46 27.86
50,500 12,750
30.30 7.65
76,900 19,200 |
12.00 3.00
69,552
6.96
3.175
1.91
4,800
.80
This Table was prepared hy the Rock Island Railroad ami y.>t:'d on their bulletin boards. This Table has n direct applicaticn
to Steam Traps, Piston and Plunder Packings and Sheet Pac!ii:)c. . .v.-.s.-Manville Traps do not air bind. The pet cock with which
they are furnished docs not have to be "cracked " to allow air t,-
off and keep the (rap functioning properly. The quantity of
steam which is lost through open steam pet cocks is convinciu^A -..c*\vt\ in the chart. As regards Packings, the chatt i? cl assistance
in show.ng bow necessary it is to maintain packing boxes and tia.-;;.-.- in steam lines in a proper state of tightness.
CRMC-003616
Johns-Mairville Service to Railroads
Volume of Water at Various Pressures
At Saturation Temperatures Corresponding to Pressures Given.
Gauge Pressure, Lbs. Per Sq. In.
.3 25.3 50.3 75.3 100.3 125.3 150.3 175.3 200.3 225.3 265.3 435.3
Absolute Pressure, Lbs. Per Sq. In.
15 40 65 90 US 140 165 190 215 240 280 450
Specific Volume, V' or O
Cu. Ft. Per Lb.
0.0167 0.0171 0.0174 0.0176 0.0178 0.0180 0.0182 0.0184 0.0185 0.0186 0.0189 0.0197
Density, v, Lbs. Per Cu. Ft.
Energy of Expansion, 144 Ap V' B. t. u.
59.8 58.3 57.4 56.8 56.0 55.4 54.9 54.5 54.0 53.6 53.0 50.8
0.05 0.13
0.21
0.30 0.38 0.47 0.56 0.65 0.74 0.83 0.98 1.65
Heat Losses from Uninsulated Hot Surfaces
Steam Pressure (Gauge)
0 10
25
50-
75
100
150
200
250
Steam Temperature (Deg. Fahr.)
212
240
267
298.
320
338 366 .
388 406 :
ORDINARY STEAM TEMPERATURES Temperature of Surrounding Air 70 F.
Difference between Temper- Loss Per Sa. Ft.
ature of Steam and Sur-
Per Hour
rounding Air (Deg. Fahr.)
(B.t.u.)
142 170 197 228 250 . 268 296 318, 336.7
334 425 522.5 644 , 737.5 820 . 950 1,079 1,184 .
Per Year
293 372 458 564 646 7187 840 945 . 1,036
.
Number of Sq. Ft. of Surface That Wastes a Ton of Coal in 1 Year
6.82 5.38 4.37 3.55 3.10 2.79 2.38
2.12
1.93
Surface Temperature-' (Deg. -Fahr;)
lOOr : 120 -
.1.40-7. .. - 160: .
180 -
; 20.0.7-
TEMPERATURES LOWER THAN 212 DEG.
Difference .Between Surface Temperature
and Surrounding.
Air. (Deg. Fahr.)
Loss Per Sa. Ft. : Per Hour (B.t.u.)
F.' ' 7
Waste of Coal in Lbs; Per Sq. Ft.
' Per Year
-
30
50.'
7 70: .
90- - .
110 7
. 130- ....
:
56.6: 97.5 ' 142. 190. 242. .298.5
. 49.6
"7 '85.4
... 124-3
------ - 166.3-
212.
261.5.
-
Number of Sq. Ft. of Surface That Wastes a Ton of Coal in 1 Year
40.3
23.4 16.1
. 12.03 9.44 7.65
.Above figures .involving. waste-.of coal are .based-on 10.00.0 B. t.u. available per pound of coil, 'which is'equivalent to a boiler efficiency
of 70% usipg.coal with'an assumed heat value of about 14,000 B. t. q. per pound.1
' ." ......... -
These figures are very, conservative.-as both the1 boiler efficiency and the heat value of the coal are high--a lesser boiler efficiency or
inferior grade of coal would cause, even a greater waste in pounds of fuel.
..
' :
.The figures are based-also-on .continuous service. 24 .hours per day.
'.
Minimum Thicknesses, of Steam Pipe Insulation to be used for Given Character of Service
Steom;.r Pressures
.. . Steam . Temperatures
Thickness of Insulation for Pipes Larger than 4" in Size
Thickness of Insulation Thickness of Insulation for Pipes 2'' to 4" in for Pipes jj" to 1 ;<" Size
0 to 25 lbs.
212 to 267 F.
1" or Standard*
1" or Standard*
1" or Standard*
25 to 100 lbs.
100 to 200 lbs.
Higher Pressures { or Superheat )
267 to 338 F.
338 to 388 F.
\ 388 to 500 F. ] 500 to 600 F.
lK"
IK"
1" or Standard*
2" or D'ble Standard*
IK"
1" or Standard *
214"
3"
2" or D'ble Standard*
IK"
2K"
2" or D'ble Standard*
For higher temperatures obtain special recommendations. * Standard and Double Standard thickness apply to 85 <1 Magnesia Insulation only--other thicknesses apply to all types of insulation.
It is always preferable to apply insulation greater than 1^-inch thickness in two or more layers with all joints broken or staggered.
253
CRMC-003617
Nom inal Internal, , In.
A ctual E xternal, In.
J
Approx. Internal, In .
J
Nom inal Thickness,
External, In . 1 1
Internal, In. External, Sq. In . j Internal, Sq. In.
1 M e ta l, Sq. In . External Surface, F t. Internal S u rfa c e , F t. Length o f Pipe Con taining 1 Cu. F t., F t. N om inal W eight per F t., Lbs. No. of Threads per.In. o f Screw Area E xternal Surface per Lineal Foot, Sq. F t
Data on. Standard Full-Weight Wrought-Iron and Steel Pipe
Diameter
c Transverse Areas
Circum ference
Length of Pipe per Sq.Ft.
of
X 0.405
K 0.540
X 0.675
K 0.840
X 1.050
0.27 0.36 0.49 0.62 0:82
0.068 0.083 0.091 0.109 0.113
1.27 1.70 2.12 2.63 3.30
0.85 1.14 1.55 1.95 2.59
0.13 0.23 0.36 0.55 0.87
0.06 0.10 0.19 0.30 0.53
0.07 0.12 0.17 0.25 0.33
,9.44 14.15 7.08 10.49 5.66 7.76 4.55 6.15 3.64 . 4.64
2513.00 1383.30
751.20 472.40 270.00
0.24 27 .106 0.42 18 .141 0.57 18 .177 0.85 14 .220 1.13 14 .275
i 1.315
IK 1.660
IK 1.900
2 2.375
2K 2.875
1.05 1.38 1.61 2.07 2.47
0.134 0.140 0.145 0.154 0.204
4.13 5.22 5.97 7.46 9.03
3.29 4.34 5.06 6.49 7.75
1.36 2.16 2.84 4.43 6.49
0.86 1.50 2.04 3.36 4.78
0.50 0.67 0.80 1.07 1.71
2.90 2.30 2.01 1.61 1.33
3.65 2.77 2.37 1.85 1.55
166.90 96.25 70.66 42.91 30.10
1.68 2.27 2.72 3.65 5.79
UK -344
UK -435
UK -498 UK -622
8 .753
3 3.500
3K ' 4.000 4 4.500 '
4K 5.0005 5.563
3.07 3.55 4.03 4.51 5.05-
0.2l7 11.00 9.63
0.226 . 12.57 11.15 ,0.237- '14.14 12.65 0.246 . ' 15.71 - 14.160.259 17.48 15.85
9.62 12.57 15.90 19.64 24.31
7.39 9.89 12.73 15.96 19.99
2.24 2.68 3.18 3.68 4.32
1.09 0.96 0.85 0.76 0.69
1.25 1.08 0.95 0.85 0.76
19.50 14.57 11.31:
9.02 7.20
7.57 9.11 10.79 12.54 14.62
8 .917 8 1.047 8 1.178 8 1.309 81.456
6 6.625 7 7.625 8 8.625 8 '8.6259 ' 9.625'
6.07' 7.02: 8.07 7.98 8.94'
0.280-: 0.301 0.276 ' 0.322 0.344
20.81 19.05 23.96 22.06 27.10 ''25.35" 27.10 25.07' 30.24 28.08
34.47' 45.66 58.43 -58.43 72.76
28.89 38.74 .51.15 5Q.02 62.72
5.59 6.92 7.28 8.41 10.04
0.58 0.50 0.44 0.44. 0.40
0.63 0.54 0.47 0.48 0.43
4.98 18,97 3.72 23.54. 2.82' 24.69 2.88 , 28:55. 2.29 33.91
8 1.734 8 1.996 8 2.257 8 2,257 8 2.519
10 10.750 . : 10.19' ; .0,278 ,,33.77 32.01
10 : 10.750 10.14- ..P-306, 33.77: 31.86
-10 10.750 10:02- 0.366 33.77 3.1.47'
11 ' 11.750- 11.00 0.375 36.91 34.56
12 12.750 12.09 0.328 40.06 ; 37.98'
. 90.76 -90.76 '90.76
108.43 127.68
81.55 80.75 78.82 95.03 114.80
9.21 10.0.1 11,94 13.40 12.88
0.36 0.36 0.36 0.33 0.30
0.37 0.38 .. 0.38 , 0.35 0.32
,1.76' ,,31.20 1.78 '34.24' 1.82 40.48 1.S1 45.56 1:25 . 43.77'
8 2.817 8 2.817 8 2.817 8 3.073 8 3.337
12 12.750 140D 14.000 150D 15.000 160D 16.000
12.00 13.25 14.25 15.25
0.375' 0.375 0.375 0.375
40.06 37.70 43.96 . 41.60 47.10 44.70' 50.27 47.90
127.68 153.86 176.62 200.96
113.10 137.81 159.39 182.55
14.59 16.05 17.23 18.41
0.30 0.27 0.25 0.24
0.32 0.29 0.27 0.25
- 1.27 1.04 0.90 0.75
49. S6 54.57 58.57 62.58
8 3.338 8 3.663 8 3.927 8 4.188
i
i 254
CRMC-003618
Johns-Manville Service to Railroads
Total Radiation Areas and Equivalents of Standard Flanged Fittings
Including the accompanying flanges bolted to the fitting
Figures in columns under "Area' give surface areas in SQUARE FEET. Figures in columns under "Pipe Lengths" give the number of feet of pipe
which has an area equivalent to the area of the fittings.
Size I. D. 1"
I1HH""
2V2"
3
3M
4 411"
5" 6"
r
9"
10" 12"
iV'O.D, 15" O.D. ..
16" O.D,
Flanged Coupling
Area
Pipe Lengths
.320 .533 .477
.93
ss
95
.672 S41
.945
1.06 1.12 1.03
1.122 1.344 1.474
1.07 1.14 1.13
1.622 1.82 2.17
1.11 1.049 1.097
2.41 3.00 . 3.43 .4.41
1.067 1.19 1.22 1.32
5.39 . 6, IS
6.6<J
V .465 . 1.572
K60
90 Ell
Area
Pipe Lengths
795 .957 1.174
2.31 2.20 2.35
1.6S 2.09 2.38
2.65 2.78 2.60
2.98 3.53 3.95
4.44 5.13 6.17
2.85 2.90 3.01
3.049 2.95 3.09
6.98 8.71 10.18 13.08
3.09 3.457 3.61 3.92
16.38 38.50 20.17
4.47 4.72 4.82
Long Radius Ell
Area
Pipe Lengths
.892 1.0S4 1.337
2.59 2.49 2.68
1.84 2.32 2.68
2.96 3.08 2.93
3.28 3.96 4.43
3.13 3.36 3.38
5.00 5.99 7.3S
3.43 3.45 3.697
8.56 10.57 12.3S 16.35
3.79 4.20 4.38 4.90
20:17 22.92 25.41
5.47 5.83 6 07
Tee
Area
1 .235 1.481 1.815
Pipe Lengths
3.59 3.40 3.64
Cross
Area.
Pipe Lengths
1.622 1.943 2.38
4.72 4.47 4.78
2.54 3.21 3.66
4.08 4.26 3.99
3.32 4.19 4.77
5.34 5.56 5.70
4.48 5.41 6.07
4.28 4.59 4.63
5.83 7.03 7.87
5.56 5.97 6.01
6.81 7.84 9.37
4.67 4.53 4.69
8.82 10.08 12.00
6.06 5.81 6.01
10.55 13.18 15.41 19.67
4.67 5.23 4.47 5.59
.
13.44 16.78 19.58 24.87
5.96 6.66 6.95 7.45
24.81 27,91 30.32
6.78 '31.48
7.10
35.48
. 7.23
38.34
8.60 9.04 9.15
"otal Rad iation Areas a nd "Squrtalent s of Extra Heavy Flanged Fittings
. Including, the accompanying flanges bolted to the fittincr
Figures, in columns under "Area' giye surface areas in SQUARE FEET.
:.
Figures in columns under "Pipe Lengths" give the number of feet of pipe ,.
'which has an area equivalent to the area of the fittings.'
Size I. D1
1"
i Yi' 1" 2w
y
y/2
4" 412"
5" 6'
?'J
8" 9" 10" 12"
14" O.D. 15" O.D. 16" O.D.
Flanged. Coupling
' .... -
Pipe
. Area
Lengths
1. . 43S .510 .727
' 1.273 1.172 1.459
' \S4S
1.107 1.434
'1.363
1.463
1.619
1.644 1.914 2.04
1.57 1.624 1.553
2. IS 2.7S 5.46
1.497 1.603 1.733
3.77 4.-44 5.20 6.71
1.670 1.762 3.846 2.01
S.30 9.52 10.05
2.26 2.43 2.4
90 EU
Area
Pipe Lengtns
1.015 1.098 1.332
2.95 2.524 2.674
. . Long Radius EU
Area LePnipgeths
1.055 1.340 .1.874
3.148 3.08 3.762
2.01 2.57 3.49
3.23 '3.41 3.807
2.16 2.76 3.74
3.473 3.665 4.08
3.96 4.64 5.02
3.782 3.938 3.834
4.28 4.99 5.46
4.087 4.236 4.170
5.47 6.99 S.62
3.756 4.031 4.318
6.02 7.76 9.73
4.134 4.475 4.874
9.76 11.44 13.58 17.73
4.324 4.541 4.82 5.31
11.09 13.17 15.60 18.76
4.913 5.228 5.538 5.622
22.31 25.2S 2; . IS
6.08 6 43 6.475
25.70 29.34 31.73
7.02 7.47 7.57S
Area
Tee
' Pipe
Lengths
1.575 1.92S 2.68
4.578, 4.425 5.381
3 09 4.05 5.33
4.968 5.37S 5.S15
6.04 7.07 7.72
5.76S 6.001 5.897
S .52 10.64 12.33
5 .SSI 6.136 6.177
14.74 17.23 20.41 26.65
6.531 6.84 7.245 7.987
33.63 3S.04 40.94
9.18 9.68 9.775
Cross
Area
. 2.07 2.53 3.54.
Length*
. 6.02 5.816 7.108
.
4.06 5.17 6.95
6.528 6.865 7.582
7.89 9.24 10.07
7.535 7.843 7.692
10.97 13.75 16.83
7.534
7.929 8.431
18.97 22.10 26.26 34.11
8.405 8.773 9.322 10.222
43.15 48.79 52.35
11.75 12.4 12.5
255
CRMC-003619
Johns-Manville Service to Railroads
Table of Decimal Equivalents
OF MILLIMETERS AND FRACTIONS OF MILLIMETERS
OF 8THS, 16THS, 32DS, AND 64THS OF AN INCH
' 'too = .0003937"
mm. Inches
` :o = .00079 - so -- .00157 5 50 = .00236 s* = .00315
5/5o = .00394 so = .00472 -50 = .00551
so = .00630 S 'so = .00709
= .00787 n so = .00866
so = .00945 `5 io = .01024 'so = .01102
15 jo = .01181 >e 50 = .01260 i-'io = .01339 >5 so = .01417 ' jo = .01496
so so = .01575 -> so = .01654 "so = .01732 "'so = .01811 " so = .01890
so = .01969 Jfi so = .02047
50 = -02 1 26 "so = .02205 m so = .02283
m so = .02362 so = .02441
i- s., = .02520 so = -02598
si ;o = .02677
s'. 5,, = .02756 3" = .02835' . a: 3,, =='.02913 '> so = .02992
mm. Inches
so = .03071 *oiso = .03150
*',-5o= .03228 `-'so = .03307 so = .03386 /jo = .03465
so = .03543 so = .03622 so = -03701 'jo = .03780 a, so = .03858
1= 23= 4=
.03937 .07874 .11811 .1S748
5= 6= 7= 8= 9=
.19685 .23622 .27559 .31496 .35433
10 = 11 = 12 -- 13 = 14=
.39370 .43307 .47244 .51181 .55118
15 = 16 = 17 = 18 = 19 =
.59055 .62992 .66929 .70866 .74803
20 = .78740 21 = .82677 22 = .86614 23 = '.90551 24= i.94488
25.= .98425 26 = 1.02362
mm. Inches
27 = 1.06299 28 = 1.10236 29 = 1.14173
30= 1.18110 31 = 1.22047 32 = 1.25984 33 = 1.29921 34= 1.33858
35 = 1.37795 36 = 1.41732 37 = 1.45669 38= 1.49606 39= 1.53543
40= 1.57480 41 = 1.61417 42 = 1.65354 43 = 1.69291 44 = 1.73228
45 = 1.77165 46 = 1.81102 47 = 1.85039 48 = 1.88976 49 = 1.92913
50 = 1.96850 51 = 2.00787 52 = 2.04724 53 =2.08661 54 = 2.12598
55 = 2.16535 56 = 2.20472 57 = 2.24409 58 = 2.28346 59 = 2.32283
60 = 2.36220 61 = 2:40157 62 = 2.44094 63 = 2.48031
mm. Inches
64 = 2.51968 65 = 2.55905 66 = 2.59842
67 = 2.63779 68 = 2.67716 69 = 2.71653 70 = 2.75590 71 =2.79527
72 = 2.83464 73 = 2.87401 74 = 2.91338 75 = 2.95275 76 = 2.99212
77 = 3.03149 78 = 3.07086 79 = 3.11023 80 = 3.14960 81 =3.18897
82 = 3.22834 83 = 3.26771 84 = 3.30708 85 = 3.34645 86 = 3.38582
87 = 3.42519 88 = 3.46456 89 = 3.50393 90 =3.54330 91 =3.58267
92 = 3.62204 93 = 3.66141 94 = 3.70078 95 = 3.74015 96 = 3.77952
97 = 3.81889 ' 98 = 3.85826 '99 = 3.89763 100 = 3.93700
lOmra. -- 1 Centimeter .= 0.3937 inches ,10 cm. ' =' 1 Decimeter = ,3.937 inches' ; -
10 dm. = 1 Meter = 39.37 inches 25.4 mm. = 1 English inch
'../,
8ths
xs = .125 )i = .250 A = .375 i.; = .500
= .625 % = .750 A = .875
lfiths
` 16 .0625
J 16 .1875
J 16 .3125
` 16 .4375
j 16
.5625
"l6 = .6875
15 w = -8125
is, = .9375
32ds
'j, = .03125 8 a. = .09375
.15625 .21875 .28125 .34375
13^ .40625 ,s4 .46875 17-6 .53125 lt6 .59375 2 % .65625 M-4 .71875 2i-6 .78125
2'-4 .84375 .90625
814 .96875
64ths
16 = .015625
% = .046875 V6 = .078125 W4.= -109375,
= .140625 . .171875 ;"i*6.= -203125
- .234375'
'Cl .265625
19'6 .296875 2'4l .328125
.359375
K4i .390625 .421875
.453125
3I4 = .484375
= .515625
35^ = .546875
= .578125
3Vi = .609375
ii / '61
_
--
.640625
= .671875
= .703125 _A4 7/6y4 -- .734375
= .765625
5'4 = .796875
53 ' -61
= --
.828125
a''61_ ~ .859375
a'.-4 -= .890625
59.' '64
=
--
.921875
61 ' -- .953125
.984375
AL'ircumierences ana /\reas or v^ircies
Diam: Cite/ Area Diam; . Circ. Area-. - Diain.
-16
A-
" 16
Jf
's *'w
A 1 \f>
*
' tic
.0981 .1963 .3926 .5890 . .7854 .9817 1.178 1.374 1.570 1.767 1.963 2.159 2.356 2.552 2.748 2.945
'3;T-'
.00076
.00306 '
.01227 <
.02761
A :A
.04908
.07669 : .1104 .1503
A
.1963
4
.2485
A
.3097
'.4
.3712 ' a
.4417
.5184 .6013
3 34
.6902
'
9;424 . 9;817 10.21' 10.6010/99 ' 11.38
1-1:78' 12.17
7.068 1 7 '
7.669
8:295 ; 8:946 "
9:621
10:320 .:
IS A
11.044
X
11.793
12.56 12,95. 13.35 13.74 14.13 14.S2 14.92 15.31
12.566 13.364 14.186 15.033 15.904 16.800 17.720 18.665
8
a
u
1 3.141 .7854
V* 3.534 .9940 a 3.927 1.227
A 4.319 1.484 4.712 1.767
* i 5.105 2.073 A 5.497 2.405 ' H 5.890 2.761
2 a A
a
A 'b
6.283 6.675 7.068 7.461 7.854 8.246 8.639 9.032
3.141 3.546 3.976 4.430 4.908 5.411 5.939 6.401
5 H A A A /i A X
6 H H X
rj J
X y
15.70 16.10 16.49 16.88 17.27 17.67 18.06 18.45
18.84 19.24 19.63 20.02 20.42 20.81 21.20 21.57
19.635 20.629 21.647 22.690 23.758 24.850 25.967 27.108
28.274 29.464 30.679 31.919 33.183 34.471 35.784 37.122
9 !i
?4
10 Is M
s '4
Circ.1 Area Diam.
21.99 22/38 ' 22.77-'
23.16. 23.56 23.95 24.34 24.74.
38.484 39/871 41.282 42:718 44.178 45:663 47:173 48.707
11 L.*
\y \-
j.
25.13 25.52 25.91 26,31' 26.70 27.09 27.48 27.88
50.265 51.848 53.456 55.088 56.745 58.426 60.132 61.862
12
y% >A :iy 1'
3'
28.27 28.66 29.05 29.45 29.84 30.23 30.63 31.02
63.617 65.396 67.200
69.029 70.882 72.759 74.662 76.588
13 \< H
Y.
31.41 31.80 32.20 32.59 32.98 33.37 33.77
34.16
78.539 80.515 82.516 84.540 86.590 88.664 90.762 92.885
14 A Va /._ h
3-:*
Circ. Area. Diam.- . Circ.
34.55 34.95 35.34 35.73 36.12 36.52 36.91 37.30
. 95.033 .97.205
99.402 101.62 103.86 106.13 108.43 110.75
15
!j '
H H] - '
5;
47.12 47.51 47.90 48.30 ,48.69 49.08 .49.48 49.87
37.69 38.09 38.48 38.87 39.27 39.66 40.05 40.44
40.84 41.23 41.62 42.01 42.41 42.80 43.19 43.58
43.98 44.37 44.76 45.16 45.55 45.94 46.33 46.73
113.09 115.46 117.8S 120.27 122.71 12S.18 127.67 130.19
132.73 135.29 137.88 140.50 143.13 145.80 148.48 151.20
153.93 156.69 159.48 162.29 165.13 167.98 170.87 173.78
16 1< K
^
u s
17 1^ u l
A `S
18 is
U 1
50.26 50.65 51.05 51.44 51.83 52.22 52.62 53.01
53.40 53.79 54.19 54.58 54.97 55.37 55.76 56.16
56.54 56.94 57.33 57.72 58.11 58.51 58.90 59.20
Area'. Diam. Circ. . Area
176^71 . 19
179.67 182.72 1.85.66 188.69
'H u 1 .C It
191.74
194.82
A
197.73
59.69 60.08 60.47 60.86 61.26 61.65 62.04 62.43
283.52 287.27 291.03 .294.83 298.64 302.48 3C6.35 310.24
201.06 204.21 207.39 210.59 213.82 217.07 220.35 223.65
20
.n A
.i j
A
62.83 63.22
63.61 64.01 64.40 64.79 65.18 65.S8
314.16 318.00 322.C6 326.05 330.06
334.1C 338.16 342.25
226.98 230.33 233.70 237.10 240.52 243.97 247.45 250.94
254.46 258.01 261.58 265.18 268.80 272.44 276.11 279.81
21 N
J
A
22 lk A
15 ^
!> '
65.97 66.36 66.75 67.15 67.54 67.93 68.32 68.72
69.11 69.50 69.90 70.29 70.68 71.07 71.47 71.86
346.36 3SC.49 354.65 358.84 363.05 367.26 371.54 375.82
380.13 384.46 388.82 393.2C 397.6C 402.03 406.49 410.97
256
CRMC-003620
i l
Johns-Manville Service to Railroads
Circumferences and Areas of Circles
Diam. Circ. Area Diam. Circ. Area Diam. Circ. Area Diam. Circ. Area Diam. Circ. Area Diam. Ciic. Area
23 }s
X3 .
U ti
H
72.2S 72.64 73.04 73.43 73.82 74.21
74.61 75.00
415.47 420.00 424.55 429.13 433.73 438.30 443.dl 447.69
34
X X Vs X Vs X V*
106.8 107.2 107.5 107.9 108.3 108.7 109.1 109.5
907.92 914.61 921.32 928.06 934.82 941.60 948.41 955.25
45
H X
if
Vs X
141.3 141.7 142.1
142.5 142.9 143.3 543.7 144.1
1S90.4 1599.2 1608.1 1617.C 1625.9 1634.9 1643.8 1652.8
56
Ys X X Vs H Xy$
24
Vi X3 . X
25
X
>4
J-3
X X
26 J< ?<'
lA X Vs X X
75.39 75.75 76.18 76.57 76.96 77.36 77.75 78.14
452.39 457.11
461.86 466.63 471.43
476.25 481.10 485.97
78.54 78.93 79.32 79.71 80.10
80.50 80.89 81.28
490.87 495.79 500.74 505.71 510.70
515.72 520.70 525.83
81.68 82.07
82.46 82.85 83.25 83.64
84.03 84.43
530.93 536.04
541.18 546.35 531.54 556.76
562.00 567.26
35
X X Vs X Vs H Vs
36
X X
H
SA X Vs
37
X X X X
X yi
109.9 110.3 110.7 lll.l 111.3 111.9 112.3 112.7
962.11 968.99 975.90 982.84 989.80 996.78 1003.7 1010.8
113.0 113.4 113.8 114.2 114.6 115.0
115.4 115.8
1017.8 1024.9 1032.0 1039.1 1049.3 1053.5 1060.7 1067.9
116.2 116.6 117.0
117.4 117.8 118.2
118.6 118.9
1075.2 1082.4
1089.7 1097.1 1104.4 1111.8
1119.2 1126.6
46
Li X X
)K
Vs X `/t
47
H X Vs X X X
48
X X
1>
s.< X ys
144.5 144.9 145.2 145.6 146.0 146.4 146.8 147.2
147.6 148.0 148.4 148.8 149.2 149.6 150.0 150.4
150.7 151.1 151.5 151.9 152.3 152.7 153.1 153.5
1661.9 1670.9 1680.0 1689.! \698.2 1707.3 1716.5 1725.7
1734.9 1744.1 1753.4 1762.7 1772.0 1781.3 1790.7 1800.1
1809.5 1818.9 1828.4 1837.9 1847.4 18S6.9 1866.5 1876.1
57
Vs X Vs X Vs X
58 X X X l! X
59
Vs X X X Vs X 7i
27
X X H X : XX
Vs : X
VsX . ' Vi
'
84.82 572.55
85.21 577.87 85.60 583.20 86.00 588.57 86.39 . 593.95 86:78 599.37
87:17 604.80
'87.57 610.26
38
X :x Vs
- 5i,;i.
X>9 :
119.3 1134.1 119.7 1141.5' 120.1 1149.0
120:5 ' 1156.6 120:9' 1164.1
121.3 117.i:7 121.7 1179.3
I22:i. 1186.9'
49
. V}s:
X .. >A
xis x
87.96 615.73
: 88.35 621.26
. 88.75 .626.79 89.1-41 632.35 89:S3 637.94
. 89.92 643.54
"90.32 : 649.18 90.71 654.83
'39:. 122.5 1194.5 '
X 122.9; 1202:2
Xz.: .
. 123.3- 1209.9 123.7."'1217.6-
j j 124.0 1225.4.
u,..
'
124.4 1233:1.. 124:8:.' 1240.9 :
.125.2 1248.7,
50
. Vs X
ii* j4
H U--
153.9 1885.7 154.3 1895.3
154.7 . 1905.0 155.1 1914.7 155.5 1924.4 155.9 1934.1 156.2 1943.9
156.6 .1953.6
60
Vs
X
u
X
.X
Vs
157.0 .
157A-
157.8, -
158.2 158.6 159.0 . 159.4 . 159.8
1963.5 61
1973.3 :
1983.1
1993.0
x X Vs
2002.9 X
2012.8
2022.8
x
2032.8
29
X X . Vs X H a>'8;
91.10 91.'49
660.52 666.22
*
:40\i''
'
'91.89 671.95 . x
92.28 677.71
92.67 683:49 93.06 689.29
',
X::
3.
. 93.46 695.12 S ' X -
193.85 700:98
125:6"- X256.'6126,0. 1264.:S'. 126.4 1272.3 ' 126.8 I2S0.3 127.2: 12S8;2. 127.6 129-1:2
1:28.0 1304.2 128.4 1312.2'
51 160:2
.. 3 s - .160.6.
731y
161.0 , 161.3
1,, 16i:7
ii < 162.1
X 162,5
162.9
2042.8 62
2052.8 2062.9
<
X
2072.9
X
2083.0 . X
2093.2
2103.3 X
2113.5
ys
30;
Vs H %
X V
31
H X Vt X
X A
94.24 94.,64 95.03 95.42 95.81 96.21 g6.60 96.99
706.86 '41 712.76 * t.?* '
718.69 724.64
aX,;
730.61 736.61
X* .
742.64 748.69
X >9
97.38 97.78
98.17 98.56 98.96 99.3S 99.74 100.1
754.76 760.86 766.99 773.14 779.31 785.51 791.73 797.97
42 )
X X
X
128.8 1 1320:2 129.1 1328.3' 129.5 1336.4 129.9 1344.5 130.3 1352.6 130.7 1360.8
131.1 1369.0 131.5 1377.2
' 131.9 13S5.4 132.3 1393.7 132.7 1401.9 133.1 1410.2 133.5 1418.6 133.9 1426.9 134.3 1435.3 134.6 1443.7
>2
31"
X V1 s'
51
x Vi
163.3 163.7 164.1 164.5
164.9 165.3 165.7
166.1
2123.7 '63.
2133.9 2144.1 2154.4
X X.1 '
2164.7
Ys
2175.0 2185.4
X X
219S.7
ys
53 H
X
3$ *i 5.
34
166-5. 166.8
167.2 167.6 168.0 168.4 168.8 169.2
2206.1 2216.6 2227.0 2237.5 2248.0 2258.5 2269.0 2279.6
64
A X X H Vs
32
X X X 2 % X Vs
100.5 100.9 101.3 101.7 102.1
102.4 102.8 103.2
804.24 810.54 816.86 823.21 829.57 835.97
842.39 848.83
43
X X
l
55
X
135.0 135.4 135.8 136.2 136.6 137.0 137.4 137.8
1452.2 1460.6 1469.1
1477.6 14S6.1 1494.7 1503.3 1511.9
54 ?S
X
1 A,
X `$
169.6 170.0 170.4 170.8 171.2 171.6 172.0 172.3
2290.2 2300.8 2311.4 2322.1 2332.8 2343.5 2354.2 236S.0
65 ! '4
X
ii
X7/
33
M a X
u
x }n
103.6 104.0 104.4 104.8 10S.2 105.6 106.0 106.4
855.30
861.79 868.30 874.88 881.41 888.00 894.61 901.25
44
X l,
s
X
138.2 13S.6 139.0 139.4 139.S 140.1 140.5 14C.0
1520.5 1520.1
1537.S 1546.S 1555.2 1564.0 1572.8 1531.6
55
X
34
t ,,
l
V72.7
173.1 173.S 173.9 174.3 174.7
175.1 175.5
2375.8 2386.6 2397.4 2408.3 2419.2 2430.1 2441.0 24S2.0
66
Xi'
1
175.9 176.3 176.7 177.1 177.5 177.8 178.2 178.6
179.0 179.4 179.8 180.2 180.6 181.0 181.4 181.8
2463.0 2474.0 2485.C 2496.1 2507.1 2518.2 2529.4 2540.5
2551.7 2562.9 2574.1 2585.4 2596.7 2608.0 2619.3 2630.7
67 K
l1 >>
?S
H
68
X X X X X
210.4 210.9 211.2 211.6 212.0 212.4 212.8 213.2
213.6 214.0 214.4 214.8 215.1 215.5 215.9 216.3
3525.6 3538.8 3552.C 3565.2 3578.4 3591.7 3605.C 3618.3
3631.6 3645.0 3658.4 3671.8 3685.2 3698.7 3712.2 372S.7
81
}i a X
82
X1,; X
83
X }-i X
84
X
182.2 182.6 182.9 183.3 183.7 184.1 184.5 184.9
185.3 185.7 186.1 186.5 186.9 187.3 187.7 188.1
188.4 188.8 189.2 189.6 190.0 190.4 190.8 191.2
2642.0 2653.4 2664.9 2676.3 2687.8 2699.3 2710.8 2722.4
69
X X1
it >8
216.7 217.1 217.5 217.9 218.3 218.7 219.1 219.5
3739.2 3752.8 3766.4 3780.0 3793.6 38C7.3 3821.0 3834.7
2733.9 2745.5 2757.1
2768.8 2780.5 2792.2
2803.9 2815.6
70
IXt X1 ^
5;
X y'e
219.9 220.3
220.6 221.0 221.4
221.8 222.2 222.6
3848.4 3862.2 3875.9
3889.8 3903.6 3917.4
3931.3 3945.2
2827.4 2839.2 2851.0
2862.8 2874.7 2886.6 2898.5
2910.5
71
Ys :X .X
i;
X
!
;8 .
223.0 223.4 '223.8 224.2 224.6 225.0 225.4 225.8-
39S9.2
3973-1 '3987.1 4001.1
4015.1 ;4029.2 4043.2
4067.3
X
85
X
U
66
X
a 54
87
X
X
88
X
ii
X
89
X
X
191.6 192.0 192.4 192.'8 193.2 193.6 193.9 194.3
194.7 195.1 195.5 195.9 196.3 196.7 197.1 197.5
197.9 198.3 198.7 199.0 199.4 199.8 200.2 200.6
201.0 201.4 201.8 202.2 202.6 203.0 203.4 203.8
204.2 204.5 204.9 205.3 205.7 206.1 206.5 206.9
2922.4 2934.4
2946.4 2958:5
72
Vs . .X\
226.1
.226.5 : 226.9 ;
4071.5 4085.6
4114.0
90 X
X X
2970.5
2982.6 ...
2994.7 3006.9 x .
3X4'-
' 228:5"
91
X
La
3019.0 3031.2
Vs .
.' X
"92 "
3043.4
X
3055.7 3067.9 3080.2
230.?
`a " it
3092.5 3104.8
.232.0 4286.3 93 X
.74
3117.2 w
3129.6
X
232.4. 232.8
233.2
4300.8
4315.3 4329.9
k
3142.0
233.6 4344.5 94
3144.4
X 234.0 ; 4359.1 . X
3166.9
234.4 4373.8
3179.4 3191.9 3204.4
3216.9 3229.5 3242.1
X Vs '
75'
X h
X
234.8 .235.2
235.6 236.4
4388.4 4403.1
4476.9 4506.6
X
95
X
X
X
3254.8 3267.4 3280.1 3292.8 3305.5
76
239.5
240.3 241.1
4566.3 4596-3 4626.4
96 X
X X
77 241.9 4656.6 97
3318.3 3331.0 3343.8 3356.7 3369.5 3382.4 3395.3 3408.2
x X X
78 *; 1j
X
242.6 243.4 244.2
245.0 245.8 246.6 247.4
4686.9 4717.3 4747.7
4778.3 4809.0
4870.7
X X X
98
X Vi X
207.3 207.7 208.1 208.5 208.9 209.3 209.7 210.0
3421.2 3434.1 3447.1 3400.1 3473.2 34S6.3 3409.3
3512.5
79
l
80
! ]
{,,
X
248.1 4901.6 99
250.S
251.3 252.1 252.8 253.6
499S.1
5026.5 5058.0 5089.5 5121.2
100 JX'
it
254.4 255.2 256.0 256.8
5153.0 5184.8 5216.8 5246.8
257.6 258.3 259.1 259.9
5281.0 5313.2 5345.6 5378.0
260.7 261.5 262.3 263.1
5410.6 5443.2
5476.0 5508.8
263.8 264.6 265.4 266.2
5541.7 5574.8
5607.9 5641.1
267.0 267.8 268.6 269.3
5674.5 S707.S
5741.4 5775.0
270.1 270.9 271.7 272.5
5808.8
5842.6 5876.5
5910.5
273.3 274.1 274.8 275.6
276.4 277.2 278.0 278.8
5944.6 5978.9 6013.2 6047.6
6082.1 6116.7 6151.4 6186.2
279.6 280.3 281.1 281.9
6221.1 6256.1 6291.2 6326.4
282.7 283.5 284.3 285.1
6361.7 6397.1 6432.6 6468.2
.285.8. .,6503.8
286.6 6539.6 287.4 6575.5 288.2 . 6611.5
289.Q" 6647.6 289.8 6683.8
290.5 ' 6720.0 291.3 67S6.4
292.1 6792.9 292.9 6829.4 293.7 .6866.1
294.5 . 6902.S
295.3 296.0 296.8 297.6
6939.7 6976.7 7013.8 7050.9
298.4 299.2 300.0 300.8
7088.2 7125.5 7163.0 7200.5
301.5 302.3 303.1 303.9
7238.2 7275.9 7313.8 7341.7
304.7 305.5 306.3 307.0
307-8 308.6
7389.8 7427.9 7466.2 7504.5
7542.9 7581-5
310.2 311-0
313.3
314.1 314.9 315.7 316.*
7697.7 7736.6 7775.6 7814.7
7853.9
257
CRMC-003621
Johns'Martville Service to Railroads
Fahrenheit and Centigrade Conversion Table
Cent.
0 s 10 15
20 25 30 35
40 45 50 5S
60 65 70 75
80 85 90 95
100 105 no 115
120 125 130 135
140 . 145
! 150 ;155
.160 165 : 170 175
180 185 ,190 105
!:: 200 205
. ! 210
215 220 225
Fahr.
32 41 50 59
68 77 86 95
104 113 122 131
140 149 158 167
176 185 194 203
212 221 230 239
248 257 266 .275
284 293 .302 -311;. i2q
329 .338 347
.356 365 374 3.83
3,92 .401 :41Q
.419 428 437
Cent. Fahr. Cent. Fahr.
230 446 235 45S 240 464 245 473
460 860 465 869 470 878 475 887
250 482 255 491 260 500 265 509
480 896 485 905 490 914 495 923
270 518 275 527 280 536 285 545
500 932 505 941 510 950 515 959
290 554 295 563 300 572 305 581
520 968 525 977 530 986 535 995
310 590 315 599 320 608 325 617
540 1004 545 1013 550 1022
555 1031
330 626 335 635 340 644
345 653
560 1040 565 1049 570 1058 575 1067
350 662
580 1076
355 671
585 1085
360 680
590 1094
365 689 . 595 : U03
370 698 375 707 380 716 385 / -725;
'600 1112 605 1121 r 610 1130 015 1139
390 '734 395 , >.'743 400 752 .405.- ; 76i
.
620 ;.1148 625 1157630 1166
635 1175 '
410 770 : 640 ; 1184
415
779
645 1193
.420
788
650 1202
; 425. - 797: 655 : 1211 -
430 :435 ; 44p .
-806 815 .824
660 : 1220 665 1229 670 1238
' 445
833
' 450 . . 842
455 - '851
. 67:5 ' 1247 680 ' 1256
-685 1265
Cent. Fahr.
690 1274 695 1283 700 1292 705 1301
710 1310 715 1319 720 1328 725 1337
730 1346 735 1355 740 1364 745 1373
750 1382 755 1391 760 1400 765 1409
770 1418 775 1427 780 1436 785 1445
790 1454 795 1463 800 1472 805 1481
810 1490 815 1499 820 1508 825 1517
830 1526 835 ; 1535 840 .1544 45 : :1553 850 >1562 855 ;l57l 860 ,1580 ; 865 ;1589
870 ;i598 875 1607 880' 1616 i 885 : 1625
890' 1634 ' 895: 1643 ' 900' v .1652
905 -1661 9io -1670 915 1679
Cent.
920 925 030 935
940 945 950 955
960 965 970 975
980 985 990 995
1000 1005 1010 1015
1020 . 1025
1030 1035
1040 1045 1050 1055
1060 1065 1070 1075
1080 1085 1090 1095
1100 1105 mo 1115
1120 1125 1130
1135 1140 1145
Fahr. Cent. Fahr.
Cent.
1688 1697 1706 1715
1150 1155 1160 1165
2102 2111 2120 2129
1380 1385 1390 1395
1724 1733 1742
1751
1170 1175 1180 1185
2138 2147 2156 2165
1400 1405 1410 1415
1760 1769 1778 1787
1190 1195
1200 1205
2174 2183 2192 2201
1420 1425 1430 1435
1796 1805 1814 1823
1210 1215 1220 1225
2210
2219 2228 2237
1440 1445 1450 1455
1832 1841 1850 1859
1
1230 1235 1240 1245
2246 2255 2264 2273
1460 1465 1470 1475
1868 1877 1886 1895
.
1250 1255 1260 1265
2282 2291 2300 2309
1480 1485 1490 1495
1904 1913 1922 1931
1270 1275 . 1280 . 1285
2318 2327 2336 2345
1500 1505 1510 ' 1515
1940 1290 1949 1295 1958 1300 1967 - 1305
2354 2363 2372 2381
1520 1525 1530 . 1535
1976 1985 1994 2003
1310 1315 1320 1325
: 2390 2399
\.:.2408'.- . ' , 2417.
1540 1545 1550 1555
2012 2021 2030 2039
. 1330, ,1335
1340 - 1345'
2426 2435. 2444 2453
1560 x 1565
1570 1575
2048 ;1350 2462
2057: ' .1355 ; .2471 2066, 1360 2480
1580 : 1585
1590
2Q75 ' 2084
2093
v 1365 ,1370
1375
2489 2498
2507
> 1595 1600
Fahr.
2516 2525 2534 2543
2552 2561 2570 2579
2588 2597 2606 2615
2624 2633 2642 2651
2660 2669 2678 2687
2696 2705 2714 2723 ~ 2732
2741 2750 2759
2768 2777 2786 2795
2804 2813 2822 2831
2840 2849 2858 2867
2876 2885' 2894;
2903 2912
Metric Conversion Table
Millimetres y. .03937 -- inches.
Millimetres -r 25,4
inches.1
Centimetres X .3937 cr inches.
Centimetres ~ 2.54
inches.
Metres X 39.37 =r inches. (Act of Con
gress.)
Metres X 3.281 = feetMetres X 1.094 = yards.
Kilometres X -621
miles,
Kilometres ~ 1.6093 =: miles.
Kilometres X 3280.8693 = feet.
Square Millimetres X .00155 = sq. inches.
Square Millimetres ~ 645.1 = sq. inches.
Square Centimetres X .155 = sq. inches.
Square Centimetres -X 6.451 -- sq. inches.
Square Metres X 10.764 = sq. feet.
Square Kilometres X 247.1 = acres.
Hectare X 2.471 = acres.
Cubic Centimetres-7- 16.383 = cubic inches.
Cubic Centimetres -f- 3.09 -- il. drams (U.S.P.)
Cubic Centimetres -r- 29.57 =; fluid ounce
<U.S.P.>
Cubic Metres X 35.315 =; cubic feet.
Cubic Metres X 1.308 = cubic yards.
Cubic Metres X 264.2 = gallons (231.
cubic inches.)
Litres X 61.022 = cu. in. (Act of Con gress.)
Litres
33.84 = fluid ounces (U.S.P.)
Litres \ .2642 = gallons (231. cu, in)
Litres -f- 3.78 = gallons (231. cu. in.)
Litres -r- 28.316 = Cubic leet.
Hectolitres X 3.531 =: cubic feet.
Hectolitres X 2.84 =.bushels (2150.42 cu. inches.)
Hectolitres X .131 =; cubic yards.
Hectolitres d-26.42 = gallons (231. cu. in.)
Grammes X 15.432 = grains. (Act of
Congress.)
Grammes
961. -- dynes.
Grammes twater) -r- 29.57 = fluid ounces.
Grammes
28.35
ounces avoirdupois.
Grammes per cu. cent, -j- 27.7 = lbs. per cubic inches. .
Joule x .7373 = foot pounds.
Kilo-grammes X 2.2046 = pounds.
Kilc-grammes X 35.3 := oz. avoirdupois.
Kilo-grammes -r- 907.2 = tons (2,000 lbs.)
Kilo-grammes per sq. cent. X 14.223 = lbs. per sq. in.
KiJo-gram-metres X 7.233 = foot lbs.
Kilo-gr. per Metre X .672 -- lbs. per foot.
Kilo-gr. per Cu. Metre X .062 = lbs. per cubic feet.
Tonneau X 1.1023
tons (2.000 lbs.)
Kilo-Watts X 1-34 = Horse Power.
Watts -f- 746. = Horse Power.
Watts X .7373 = foot pounds per second.
Calorie
3.968 = B. t. u.
Chcval vapeur 4- .9863
Horse Power.
^Centigrade X 1.8) -1- 32
degree Fahr.
Gravity Paris = 980.94 centimetres per sec.
258
CRMC-003622
Johns-Manville Service to Railroads
INDEX
A Page
Accessories, Roofing ............................................................... 185
Acid-proof Industrial Flooring .................................. 217-218
Acme-Keystone Hair Insulator ......................................... 205
Acoustical Correction, Architectural .............................226
Aertite Boiler Wall Coating ................................................. 59
Air Brake Packing Cup Expander Ring ...................... 74
Air Pump Gaskets, Top Head and Bottom Head ... 90
Air Pump Lagging, 85% Magnesia ............................... 40
Air Pump Packing,
--Kearsarge ..............................................
77
--Keystone ................................................................................ 79
--Moulded .................................................................................. 79
--Special Combination ....................................................... 78
Anti-Sweat Sectional Pipe Insulation ........................... 29
Appendix .......................................................................................... 247
Approval of Roofings by Underwriters .......................... 120
Aquadam (for waterproofing) ........................................... 223
Architectural Acoustics, Correction of ............................226
Arctic-Keystone Hair Insulator ......................................... 205
Areas and Circumferences of Circles .............................. 256
Areas, of Flanged Fittings, Radiation ............................255
Asbestocel, Improved, Pipe Insulation ....................... 21-22
--Sheet & Block Insulation ............................................ 42
--Insulation (Flexible Roll Form) ............................. 42
Asbestoment and Niagrite Cable Insulation .............. 243
Asbesto-Metallic,
--Friction Blocks ...
104
--Gasketing Tape ........................ - 87
--Gaskets* Manhole, Handhole. & Tube Plate .... 86.
--Sheet- Packing, Kearsarge
..................... : 85
--Tubular Gasketing,- Kearsarge . ...........
..'87
.Asbestos Braided Rope Packing .'.
;73
Asbestos Braided Tubing
... . ...........242
-Asbestos Brake-Lining, Non-Burn, Industrial .. ... .".107 .
.Asbestos Clothing '.. .. !.. . ; V.... . .. ........ .246
Asbestos Combination Spiral. Pipe Insulation
26
Asbestos Cord
.'73
, Asbestos .F.eltj ' Slater's - . V..'--a. .... .......... 186-
i Asbestos.' Felt, - Waterproofing
221 -
: Asbestos Fibrous 'Enamel ........ ................ 1.85 .. '
Asbestos Fire Felt
--Insulating Cement' No. 302 v.;........... ............... ..- 501:
;--Pipe insulation' . .. -........... ........................................... 24
' --Roll V......... ........................................................... ................ 45 --Sheet & Block insulation ............................................ 43
Asbestos Flexible Pipe Insulation
...................... 25
Asbestos Furnace 'Cerneiit, Fireite ................................... 60
Asbestoside, Asbestos Exterior Wall Siding ............. 146
Asbestos Insulating Cements, Nos. 302. 352. 364, 400. . 50
Asbestos Lead Joint Runner ............................................... 246
Asbestos Paper & Roll Board ............................................ 47
Asbesto-Sponge Felted Insulations,
--Sectional Pipe ..................................................................... 10
--Sheet & Block Insulation............................................... 39
--Train Pipe Insulation ..................................................... 11
ASBESTOS ROOFINGS
--Asbestos ProtectedMetal ................................................159 --Barge ........................................................................................150 --Built-up ................................................................................... 128 --FlexstoneReady-to-lay ..................................................... 142
Page --Locomotive Cab .................................................................. 149 --Transite Corrugated ......................................................... 151 Asbestos Roof Putty ................................................................186 Asbestos Sheet Millboard .........................................................47 Asbestos Slater's Felt ............................................................. 186
ASBESTOS SHINGLES
--Flexstone Brand (slate surfaced) .............................179 --Standard and Colorblende (Rigid) ........................ 167 Asbestos, Story of ..................................................................... 6 Asbestos Stove Lining, Phoenix ......................................... 60 Asbestos Waterproofing Felt ..............................................221 Asbestos Wick & Rope Packing ........................................ 73 Asbestos Wood, --Ebony ....................................................................................... 223 --Caps & Stacks, Transite ................................................ 199 --Smoke Jacks, Transite ........................................193-198 --Transite (Flat) for building purposes .................... 188 --Transite (Flat) for electrical purposes ...................230 --Ventilators, Transite ....................................................... 199 Asphalt Roofing Cement ......................................................... 186 Asphalt Saturated Fabric ....................................................... 221 Asphalt Waterproofing Cement ......................................... 221
B
Baffle Walls* Monolithic ..................
58
Bare Pipes and other Bare Surfaces, Losses from, etc. 249
Barge Roofing, Asbestos
.150
Bituminous .Putty ................................................. . :222
Blocks,! Asbesto-Metallic Friction ... ..............
.1104
Block & Sheet,Insulation,
--Asbestpcel,. Improved .... *;
............-..'..; 42
--Asbestocel,. Flexible Roll Form ..................................... 42
--Asbestos Fire Felt. ................................... 43
--Asbesto-Sponge .Felted
39
--85% Magnesia V. ..; -:,40
--List Prices'.. . .. -. I";';:-.
......... >'. - - . 49
--Millboard, Asbestos .
-.;........... .....; 47
--Thermo Fire^Felt
... l . .. .........44
--Vitribestos ;
:v. '.. . .. ......... ..
46
--Vitro -Fire ; Felt ............ ............... .'.. i.45
--Weights' and Standard.:'Sizes .
49
Board (Roll.and Paper, Asbestos) .47
Boiler Lagging,. Locomotive; 85% Magnesia ....... 40
Boiler Manhole Gaskets, Kearsarge Asbesto-
Metallic ..............
86
Boiler Wall Coating, Aertite..................
59
Brake Lining, Non-Burn Asbestos, Industrial .............107
Brake Blocks, Asbesto-Metallic .......................................... 104
Brine and Ammonia, Insulation Built-up ....................... 27
Brooks Brand (White Top) Asbestos Ready-to-lay
Roofing ..........................................................................................143
Building Insulation (Keystone Hair Insulator) ....202
Built-up Asbestos Roofing ..................................................... 128
Built-up Hair Felt Insulation ............................................. 28
c
Cab Cock Packing, Locomotive .............. Cable Insulation, Niagrite Fireproof .. . Cab, Locomotive, Asbestos Roofing for Cab Roof Insulation, Locomotive ...........
77 243 149
97
259
CRMC-003623
Johns-Manville Service to Railroads
Page
Carinsul, Steel Passenger Car Insulation ...................... 95 Car Insulation, Refrigerator, Hairinsul ........................ 98 Car Insulation, Steel Car, SalamanderBrand ................ 92 Car Insulation, Tank Car .......................................................101 Ceilinite. Railroad Car Insulation...................................... 94
CEMENTS
--Asbestos Insulating, Nos. 302, 400, 352, 364 .... SO
--Asphalt Roofing .................................................................186
--Asphalt Waterproofing ................................................. 221
--85% Magnesia, Insulating .......................................... 50
--Fireite Asbestos Furnace ............................................. 60
--Fire Felt, No. 302 ............................................................... 50
--H-O Pipe Joint................................................................... 60
--Insulating .............................................................................. 50
--Pickling Tank ...................................................................... 222
--Refractory or High Temperature,
Nos. 20, 26, 30, 31, 32, 33 & 35 ............................... 51-5B
--Super-refractory, Nos. 33 & 35 ................................. 56
--Waterproofing, Asphalt ................................................221
--Self-Healing, Waterproofing .......................................222
Centigrade and Fahrenheit Conversion Tables............ 258
Chemical Fire Extinguisher, Success ........................... 245
Circles, Areas and Circumferences .................................... 256
Clothing, Asbestos ...................................................................... 246
Coating, -
--Aertite Boiler Wall ...... v.'.......................... 59
--Liquid Waterproof ;................ 223
--Regal Roof ..V....-. . . . . . ........................185
Coil Packing, Mogul. ..V... ..... . . ........................................ 68
Cold Water Paint
....... -......... ................... 186
"Colorbleride" andStandard- Asbestos-Shingles
(rigid) , . v.. . .
: VV V ^
......... .. ..167
" Combination.Air Pump Packing, Special ..... .. . 78
" Combination.' Spiral Pipe; Insulation .................................. 26.
Compound; Leak-no Metallic...... / ...... 60
Compounds, Rubber "'Splicing-'.".'
. ...:.. . .242
".Concrete '''Primer .. .TV.:.-;-://';;-:/T-.V./ .'221.
Conduit,. Orangeburg Fibre -C:.; V;/" TV.......... .231
Conversion Table, Centigrade ,&' Fahrenheit ........258
' Conversion; Table, Metric'-; /. T. >1 T.. ..:.. .. .............. . .258
Cord, Asbestos ... , Tv;...
.................. 73
Correction of Architectural .Acoustics ..............................226
Corrugated Asbestos Protected Metal Roofing
and Siding ......... ... T.;.. TT... /........... .......................... 159
Corrugated- Asbestos .'Roofing, and Siding, Transite .. 151-
Covering,' Sill ...........v;. v V.............................. ioo
Cut Stone. Backing
......... ..................................... ;223
D
Damp-proofing ..............................
222
Data on Wrought Iron and Steel Pipe ......................... 254
Decimals, Equivalents of ......................................................... 256
Double Coated Asbestos Ready-to-lay Roofing,
Flexstone ......................................................................................142
Duct, Underfloor, Orangeburg System of ..................... 236
Duplex Rod & Plunger Packing ........................................ 67
E
Ebony Asbestos Wood ........................................................... 228 --technical data ...................................................................... 229
Page
Efficiencies, --Asbesto-Sponge FeltedPipe Insulation ...............15-16 --Asbesto-Sponge-Felted Sheets and Blocks .... 48 --85% Magnesia Blocks ................................................... 48 --85% Magnesia Sectional Pipe Insulation......... 19-20 --Thermo Fire Felt, Sheets & Blocks ......................... 48
Efficiency Tables, How to Use......................................248 85% Magnesia Cement............. ............................................... 50 85% Magnesia Blocks, Weights of .................................. 49 85% Magnesia Locomotive Boiler and Air Pump
Lagging ...................................................................................... 40 85% Magnesia Sheet & Block Insulation.......................40 Enamel, Asbestos Fibrous ................................................185 Equivalents and Radiation Areas of Standard
Flanged Fittings ......................................................................255 Equivalents of Decimals, Table of .....................................256 Excello-Keystone Hair Insulator .....................................206 Expander Ring, Slip Type for Packing Cups ............. 74 Expansion Joint Filler .............................................................222 Express Brand, Wool Felt Pipe Insulation ............... 31 Extinguishers, Fire, Success Chemical ......................... 245
F
Fabric, Asphalt Saturated ...................................................... 221
Fahrenheit and Centigrade Conversion Tables ............ 258
Fasteners, Roofing, Pyramid Kap ......................................143
Felt, Asbestos Slater's
186
Felt, Asbestos Waterproofing
221
Felt, Hair, Standard ...............................
100
Ferrotite Cement ............
60
Fibre Conduit, Orangeburg. ...................................................231
: Fibrous Enamel, Asbestos .....................
185
Filler, Expansion Joint. ...;...... .
222
----- Fire Felt,
--Asbestos Insulating .Cement No. 302 -........... ..... 50
--Asbestos Roll,-Plain or Indented
45
-- -^-Asbestos Pipe Insulation'
.. 24
---Asbestos Sheet & Block Insulation . .... .............. 43
--Thermo Sheets and Blpcks ............
44
' --Vitro, Sheets and .Blocks:........
.............. 45.
- Fire Extinguisher,
. --Success Chemical-.:-;.V./. .'.7...................................... 245
' --Success Non-Freezing, . ........................245
Fireite Asbestos Furnace. Cerfient .............. ............
60
Fireproof Cable Insulation, Niagrite .................................243
Flanged Fittings, Radiation areas and equivalents ..255
Flange Joint Gaskets, Service and Seigelite ................ 88
Flashings and Gutters, Details of,.:...................... 138-140
Flexstone Asbestos Ready-to-lay Roofing ................... 141
Flexstone Asbestos Shingles (Slate Surface) ...............179
Flexstone Double Coated Asbestos Ready-to-lay
Roofing ........................................................................................ 142
Flooring,
--Industrial ................................................................................ 210
Friction Blocks, Asbesto-Metallic ..................................... 104
Friction Tapes ............................................................................ 241
Furnace Cement, Fireite Asbestos .................................... 60
G
Gasketing, Tape, Kearsarge Asbesto-Metallic ............ 87 Gasketing, Kearsarge Asbesto-Metallic, Tubular ... 87 Gaskets
--Air Pump, Top Head and Bottom Head .............. 90
260
CRMC-003624
Johns-Manville Sendee to Railroads
Gaskets (cont.)
Page
Page
--Jointless Tube Plate, Kearsarge ............................. 86
--Steam Pipe Insulation, Minimum Thicknesses
--Kearsarge Asbesto-Metallic Boiler Manhole,
for various services ...........................................................253
Handhole & Tube Plate ................................................. 86 --Service and Seigelite Flange Joint ........................... 88
--Tank Car Insulation ......................................................... 101 --Thermo Fire Felt Sheet & Block Insulation ... 44
--Water Gauge ........................................................................ 89
--Train Pipe (Asbesto-Sponge) .................................... 11
Gutters, Built-up, Details of .................................................. 139
--Underground System of Insulation ........................ 33
Gypsum Roof Decks, Specifications for Built-up
--Vitribestos Sheet & Block .......................................... 46
Roofing .....................................................................132 and 134
--Vitro Fire Felt .................................................................... 45
--Weights of Sectional Pipe Insulations .................. 32 H --Weights of Sheet & Block Insulations ..................49
Hair Felt Insulation,
--Wool Felt Insulation ...................................................... 31
--Built-up, pipe ...................................................................... 28
--Zero Sectional Pipe Insulation ............................. 31
--Standard, refrigerator car ..............................................100
Insulator, Keystone Hair .........................................................202
--for Buildings, (Keystone) ............................................. 202
Integral Waterproofing ...........................................................220
Hairinsul, Refrigerator Car Insulation......................... 98-99
Iron and Steel Pipe, Data on ...............................................254
Handhole, Manhole and Tube Plate Gaskets, Kearsarge Asbesto-Metallic ............................................. 86
Heat Losses from Uninsulated Hot Surfaces ............ 253 Heat Losses per Lineal Foot of Bare Pipes, etc.......... 249 High Temperature or Refractory Cements,
Nos. 20, 26, 30, 31, 32, 33 and 35 ................................. 52-58 H-O Pipe Joint Cement.......................................................... 60 Hot Surfaces, Heat Losses from Uninsulated ............ 253 How to use Tables of Insulation Efficiencies............. 248
J
Jacks, Transite Asbestos Wood Smoke ................. 193-198 Jewett Ring Packing ................................................................. 71 Joint Filler, Expansion ...........................................................222 Joint, Flange Gaskets, Service andSeigelite ................ 88 Jointless Tube Plate Gaskets, Kearsarge...................... 86 Joint Runner, Asbestos Lead ..............................................246 Junior Steam Traps .................................................................. 113
K
I Kaps, Pyramid
143
Industrial Brake-Band Lining, Non-Burn Asbestos .107
Industrial Flooring
........... 210
INSULATING CEMENTS J ' :
Kearsarge Air Pump Packing ............................................ 77
Kearsarge Asbesto-MetaUic Gasketing Tape ..................-87
Kearsarge Asbesto-Metallic Manhole, Handhole
and Tube Plate Gaskets
......... :.. 85
Asbestos. Nos.^ 352, 364.and.400. ............. ................... 50
.Fire,-Felt No, 302
50
Kearsarge Asbesto-Metallic Sheet Packing
85
-Kearsarge Asbesto-Metallic Tubular Gasketing .... 87-
85%; Magnesia ................... 50
Kearsarge Join'tiess;.;Tube Plate Gaskets ........... 86
Insulated Roof .Decks;. .:,... .... i.................130'
Kearsarge Locomotive Throttle Packing......... .............: 81:
INSULATIONS
% -
...........
..Insulation, Object of ...,.. . . .. 9
--AntLSweat Sectional Pipe
29
Kearsarge Rpd Packing '. . ;.............. ............. ...................... 66
Keystone Air Punipf Packing '.;......... .. . 79
Keystone Hair Insulator
.................... . . 202
--Asbestos Fire Felt Sectional. ............................... ;.. 24
--Asbestocel Flexible ..Roll Form ,.............. ...... 42 .
Lagging, Locomotive .Boiler, 85% Magnesia ...____40
. --Asbestos Flexible,:S;team::Pipe. Insulation . .
25. Lagging, Locomotive and Air .Pump, 85% Magnesia. .40
. --Asbesto-Sponge Felted. Sectional Pipe ........... ; 10
-Lead Joint Runner,. Asbestos ........................... . 246
---Asb,esto-Sponge; Felfedr'Sheets & Blocks ................. 39 .--Asbesto-Sponge -Felted .-Train Pipe, Sectional .; 11
Leak-no Metallic Compound
6b
.Liberty Red Rubber Sheet Packing ............... ......... 85
--Asbestos Paper. & Roll Board
:........ 47 -
Lining, Non-Burn Asbestos Drake Band, Industrial, 107
--Asbestos Roll Fire Felt .v:. ..... . ............................... 45 --Building Insulation (Keystone) ................................ 202
Lining, Asbestos .Stove, Phoenix ;.........................; 60Liquid Waterproof Coating ................................................223
--Built-up Brine and Ammonia ...................................... 27
LIST PRICES
,
--Built-up Hair Felt ......... ................................................... 28
--Ebony Asbestos Wood ...................................................229
--Carinsul Steel Passenger Car Insulation ............. 95
--Industrial Brake Band Lining, Non-Burn
--Ceilinite Railroad Car Insulation ............................. 94
Asbestos ................. ;.....................................................107-108
i
--Combination Spiral Pipe Insulation, Asbestos .. 26
--Orangeburg Fibre Conduit ......................................... 234
--85% Magnesia Sectional Pipe .................................... 17
--Sectional Pipe Insulation ............................................. 32
--85% Magnesia Blocks ................................................... 40
--Sheet & Block Insulation ............................................ 49
--Hairinsul Refrigerator Car Insulation ............98-99
--Transite Asbestos Wood ............................................. 230
--Improved Asbestocel Sectional Pipe ...................... 21
Locomotive Boiler and Air Pump Lagging,
--Improved Asbestocel, Fine Corrugated,
85% Magnesia .......................................................................... 40
Sectional ................................................................................ 22
Locomotive Cab Cock Packing ........................................... 77
--Improved Asbestocel, Sheets and Blocks ........... 42
Locomotive Cab Roofing, Asbestos.................................. 149
--Locomotive Cab Roof Insulation .......................... 97
Locomotive Cab Roof Insulation .................................... 97
--Minimum thicknesses for various services .........253
Locomotive (Mallet) Packing ............................................. 76
--Niagrite Fireproof Cable Insulation ......................243
Losses due to Steam Leakage ..............................................252
--Nycinsul Steel Passenger Car Insulation ........... 95
Losses from Bare Pipes and Other Bare
--Roll Fire Felt ..................................................................... 45
Surfaces, etc................................................................................. 249
--Standard Hair Felt Insulation ...................................100
Losses Heat from Uninsulated Hot Surfaces ............ 253
261
CRMC-003625
Johns-Manville Service to Railroads
M Page
Magnesia, 85% Cement ........................................................... 50
Magnesia, 85% Locomotive Boiler Lagging ............. 40
Magnesia, 85% Locomotive Air Pump Lagging .... 40
Magnesia, 85% Sectional Pipe Insulation .................... 17
Magnesia, 85% Block Insulation......................................... 40
Mallet Locomotive Packing .................................................. 76
Manhole, Handhole and Tube Plate Gaskets,
Kearsarge Asbesto-Metallic .............................................. 86
Metric Conversion Table......................................................... 258
Metallic Compound, Leak-No .............................................. 60
Millboard, Asbestos Sheet .................
47
Millimeters and Fractions of Millimeters,
Decimal Equivalents- of ....................................................... 256
Mineral Surfaced Roofing, Asbestos Ready-to-lay,
Flexstone ......................................................................................142
Minimum Thicknesses of Steam Pipe Insulation ,. .253
Mobilene Sheet Packing ......................................................... 85
Mogul Coil Packing ................................................................. 68
Monolithic Baffle Walls ........................................................... 58
Moulded Air Pump Packing.................................................. 79
N
Neptune Brand, Keystone Hair Insulator ................... 205 New York Air Pumps, Packing for .................................. 80 Niagrite and Asbestoment Fireproof Cable Insula
tion
243
NonrBurn Asbestos Brake Lining, Industrial .............107
Non-Freezing Fire Extinguishers, Success ................... 245
Nycinsul, Railroad Car Irisulatipn ........ . . ^ . 95
o
Orangeburg Fibre Conduit........... .......................
.231
Orangeburg Underfloor Duct .System ........................... .236
v P
PACKINGS. r - ,
--Air Pumpi .Special Combination ;:......... 78
--Air - Pump, Kearsarge ;
. ......................... 77
--Air Pump,''Keysfone:................... 79
--Air Pump, Moulded .... - :...............................
79
--Asbesto-Metallic; Gasketing-. Tape ...........
. 87.
. --Asbesto-Metallic;GasketSs Kearsarge
.. 86
--Asbesto-Metallic; Sheet, Kearsarge
.................. 85
--Asbesto-Metallic Tubular, Kearsarge ....... .... 87
--Asbestos Braided Rope. 1................... 73
--Asbestos Wick .........................................
73
--Coil, Mogul
..................
68
--Combination Air Pump, Special ..............................- 78
--Duplex Rod & Plunger . ..................
67
--Gasketing, Asbesto-Metallic Tape ............................ 87 --Gasketing, Asbesto-Metallic Tubular ....................... 87
--Gaskets, Kearsarge Asbesto-Metallic ..................... 86
--Gaskets, Kearsarge, Jointless .................................... 86
--Jewett Ring .......................................................................... 71
--Kearsarge Air Pump
77
--Kearsarge Asbesto-Metallic Boiler, Manhole. Handhole & Tube Plate Gaskets .........................
--Kearsarge Asbesto-Metallic Gasketing Tape . --Kearsarge Asbesto-Metallic Gaskets, jointless
86 87 86
87
85 79 85
77
Page
--Locomotive Throttle, Kearsarge ............................. 81
--Mallet Locomotive ........................................................... 76
--Mobilene Sheet .................................................................. 85
--Mogul Coil ............................................................................ 68
--Moulded Air Pump ....................................................... 79
--Piston, Universal ................................................................ 69
--Plunger & Rod, Duplex ................................................ 67
--Plunger & Rod, Universal............................................ 72
--Power Reverse Gear, Piston ..................................... 75
--Pump Valves Moulded, No. 206 .............................. 90
--Pump Valves Rubber .................................................... 90
--Pump Packing Recommendations ............................ 82
--Red Rubber Sheet, Liberty .......................................... 85
--Reverse Gear Piston ..................................................... 75
--Rod & Plunger, Universal .......................................... 72
--Rod & Plunger, Duplex ................................................ 67
--Rope & Wick....................................................................... 73
--Rubber Pump Valves .................................................... 90
--Sea Ring .................................................................................. 62
--Seigelite Sheet, Style No. 711 ................................... 84
--Seigelite Gaskets, Style No. 712 .............................. 88
--Service Gaskets, Style No. 61 ................................. . 88
--Service Sheet, Style No. 60.......................................... 83
--Special Combination Air Pump .............................. 78
--Universal Locomotive Throttle Packing ............. 81
--Universal Piston.................. ...... ;.................................... 69
--Universal Rod & Plunger ............................................ 72
--Universal Combination Steam Hammer .............. 70
--Valves, Pumpi Moulded,. No. 206 .............................90
--Valves, Pump, Rubber.....................................
--Wick & Rope ........................................... .......................... 73
Packing Cup Expander Ring
Paint, Cold Water . .............. .......... 186
Paper & Roll Board, Asbestos
..................! ... 47
Passenger. Car1 (Steel) Tnsulatibn. . ................................ 92
Peerless-Keystpne Hair Insulator .................................... 205
Phoenix Asbestos Stove Lining
Phoenix-Keystone Hair Insulator . ............. ............ .205
Pickling Tank; Cement ...
. ................222
Pipe Insulation Efficiency Tables. How to Use .... 248
PIPE INSULATIONS
'
90 74
60
--Anti-Sweat Sectional. . ^
............. 29
--Asbestos Combination.. Spiral
25
--Asbestos Fire Felt, Sectional.......... ........................... 24
--Asbestos Flexible Pipe ...... .................................... 25
--Asbestd-Sponge Felted Sectional .......................
10
--Asbesto-Sponge Felted Train. Pipe, Sectional ... 11
--Built-up Brine and Ammonia . .................................... 27
--85% Magnesia Sectional ................................................ 17
--Fire Felt Sectional ............................................... ... 24
--Improved Asbestocel Fine Corrugated, Sectional 22
--Improved Asbestocel, Sectional ................................... 21
--List Prices ............................................................................. 32
--Minimum Thicknesses of, for Various Services .253
--Underground System of............................. ............. 33 --Weights of Sectional ............................... ............. 32 --Wool Felt, Sectional................................... ............. 31
--Zero, Sectional ............................................ ............. 31
Pipe Joint Cement, H-0 ................................... ........... 60 Pipe, Data on Wrought Iron and Steel.......... ........... 254 Piston Packing,
--Power Reverse Gear................................... ........... 75
--Universal ........................................................
262
CRMC-003626
Johns-Manville Service to Railroads
Page
Plunger & Rod Packing, --Duplex ..................................................................................... 67 --Kearsarge ............................................................................... 66 --Universal ................................................................................. 72
Price List, Non-Burn Asbestos Brake Band Lining .................................................................................... 107-108 --Orangeburg Fibre Conduit............................................234 --Sectional Pipe Insulations..............1............................. 32 --and Weights, EbonyAsbestosWood ......................... 229 --and Weights, Transite AsbestosWood ................. 230 --and Weights, Sheet and Block Insulations ......... 49
Primer, Concrete .........................................................................221 Pump Packing Recommendations .................................... 82 Pump Valves, Rubber ............................................................. 90 Putty, Asbestos Roof ..............................................................186 Putty, Bituminous .......................................................................222 Pyramid Kaps, Roofing Fasteners ..................................... 143
R Radiation Areas and Equivalents of Flanged
Fittings ...................................................................
255
Radiator Trap ................................................................................ 114
Rag-Felt Ready-to-lay Roofings ..........................................183
Rail Covering (Third Rail) .................................................. 244
Railroad Car Insulations .............................
92-102
READY-TO-LAY ASBESTOS ROOFINGS
--Flexstone (smooth or slate surfaced) ................... 142
--White Top .................. ........................................................ 143
:Red Rubber Sheet Packing, Liberty . ............................. 85
Refractory -Cements ....................................................
51-58
.Refrigerator Car Insulation .
98
Regal Roof . Coating
./;.................................................. 185
Registration, Roof .... /...': L..................119
Re-roofing- over old wooden shingles
.................. 170
Retort Cement
.' v.'...... ... ................................. .. 55
Reverse Gear'Piston Packing .;............. ............................ 75
Ring, Expander,-Slip Type. ....................
74
Ring ..Packing, Jewrett .
;... .. ........... 71
Ring; Packing, Sea .Ring '............................. 62
Rod Packing, :Kearsarge:;;/............. ............................. 66
Rod & Plunger: Packings, : .
--Duplex -l.
--r'Kearsarge:.v................
--Universalvi.y.......
... ........... 72
Roll. Board and-Paper, Asbestos ;, -.
Roll Fire. Felt; Asbestos-Plain, or Indented ...........
67 66
47 45
Roof Coating, -Regal ....... ............ I.... ....................185
Roof Decks, Insulated ......... :
130
Roof Insulation, Locomotive Cab....................................... 97
Roofing Cement, . Asphalt ........................
186
Roofing Fasteners (Pyramid Kaps) ................................. 143
Roof Putty, Asbestos ..............................................
186
ROOFINGS
--Built-up Asbestos ..............................................................128
--Barge, Asbestos ............................. f................................ 150
--Flexstone, Slate Surfaced Asbestos .......................... 142
--Locomotive Cab, Asbestos ............................................ 149
--Rag-Felt, Ready-to-lay ...................................................183
Roofing and Siding, Asbestos Protected Metal.........159
Roofing and Siding, Asbestos, Transite Corrugated .151
Roof Registration .................................
119
Roofs, "Colorblende" ....................................................... 171-174
Rope & Wick Packing, Asbestos....................................... 73
Rosin Sized Sheathing .............................................................. 100
Page
Rubber Pump Valves .............................................................. 90
Rubber Sheet Packing, Liberty Red .............................. 85 Rubber Splicing Compound ................................................. 242
S
Salamander Steel Passenger Car Insulation ............... 92
Saturated Fabric, Asphalt ......................................................221
Savings effected by Insulating Train Pipes ............... 12 Sea Ring Packing ................................................................. 62-65
SECTIONAL PIPE INSULATIONS
--Anti-Sweat Pipe ................................................................ 29
--Asbestos Fire Felt .......................................................... 24
--Asbesto-Sponge Felted ................................................ 10 --Train Pipe Insulation ..................................................... 11
--85% Magnesia ..................................................................... 17
--Improved Asbestocel, Fine Corrugated .................. 22
--List Prices ............................................................................ 32 --Weights of ............................................................................ 32
--Zero ......................................................................................... 31
Seigelite Gaskets, Flange Joint .......................................... 88
Seigelite Sheet Packing, Style No. 711 .......................... 84 Self-Healing Cement (Waterproofing) ........................222
Service Gaskets, Flange Joint ............................................ 88
Service Sheet Packing, Style No. 60 ............................... 83 Sheathing, Rosin Sized ...........................................................100 Sheet Millboard, Asbestos ................................................... 47
SHEET PACKING
--Kearsarge Asbesto-Metallic ....................................... 85
--Liberty Red Rubber ...............
85
--Mobilene ....................................................................... ...... 85
--Seigelite, Style No. 711 . . .. .:................................... 84
--Service, Style No. 60 ....................................................... 83
SHEET & BLOCK. INSULATIONS
--Asbestocel, Improved...........
42 .
--Asbestos Fire. Felt
........... ........... 43
` --Asbesto-Sponge Felted ... .
39
..--35% Magnesia
40-
- --Improved..Asbestocel ...
42 '
. . --List .Prices . ......................................... 49-
r-^Millboard,. Asbestos
47-
. --Thermo, .Fire Felf
............. ,..- 44.
=>. .--Vitri.bestos .. '.V..V'v..........................46/
.' --Vitro Fire Felt.'.../'/ .. ............ .........4.5-
. --Weights, and Standard Sizes ...................... ....... 49
'. Shingles, Flexstone, Asbestos, (Slate Surfaced) .... 1-79 .- Shingles, Standard and "Colorblende" (Rigid) .....167
. Siding, Asbestoside
146
Siding and Roofing, Asbestos Protected Metal ..... 159
Siding and Roofing, Transite Corrugated Asbestos .151
' Sill Covering-......... ................................
;100
60 (No) Service Sheet Packing ................................
83
Sizes & Weights, Asbestos Protected Metal Roofing & Siding .....................
163
Sizes, Weights & List Prices, Sheet & Block Insulation .................................................................................. 49
Slater's Felt, Asbestos ............................................................. 186
Slate Surfaced Asbestos Ready-to-lay Roofing,
Flexstone ..................................................................................... 142
Slip Type Packing Cup Expander Ring ...................... 74 Smoke Jacks, Transite Asbestos Wood,
Types G, H, J, K and L ........................................... 193-198
Special Combination Air Pump Packing ...................... 78
Specifications for application of
--Asbestoside ............................................................................ 147
263
CRMC-003627
Johns-Manville Service to Railroads
Page
page
Specifications for Application of (cont.)
--Roofing, (corrugated) .................................................. 151
--Asbesto-Sponge Felted Sectional Insulation .... 13
--Smoke Jacks .................................................................. 193-198
--Asbestos Protected Metal ............................................ 163
--Ventilators ............................................................................ 199
--Barge Roofing ....................................................................ISO
Transite Corrugated Asbestos Roofing & Siding ...151
--Built-up Roofing ........................................................ 131-134
Traps, Junior Steam ..................................................................113
--Built-up Brine and Ammonia Pipe Insulation .. 28
Traps, Radiator ...........................................................................114
--85% Magnesia Sectional Pipe Insulation ............. 18
Traps, Steam ..................................................................................112
--Flexstone Asbestos Ready-to-layRoofings ............ 144
Tube Plate Gaskets, Kearsarge Asbesto-Metallic ... 86
--Flexstone Asbestos Shingles .............................. 181-182
--Kearsarge Jointless ........................................................... 86
--Improved Asbestocel SectionalPipeInsulation 23
Tubing, Asbestos Braided .................................................... 242
--Industrial Flooring ..................................................215-216
Tubular Gasketing, Kearsarge Asbesto-Metallic .... 87
--Insulating Cold Water Pipes ...................................... 30
Twisted Asbestos Rope Packing ....................................... 73
--Locomotive Cab Roofing ..............................................149
--Sea Ring Packing ............................................................ 65
--Standard and "Colorblende" Asbestos
Shingles ..........................................
177-178
--Transite Corrugated Asbestos Roofing & Siding 155
--Underground System of Insulation ........................ 37
Spiral Combination Pipe Insulation ............................... 26
Splicing Compound, Rubber ...........
242
Stacks and Caps, Transite Asbestos Wood.................199
Standard & "Colorblende" Asbestos Shingles (Rigid), 167
u
Underfloor Duct System, Orangeburg ........................... 236 Underground System of Insulation ................................... 33 Underwriters Approval of Roofings ................................ 120 Uninsulated Hot Surfaces, Lossesfrom ......................... 253 Union Washers .............................................................................. 90 Universal Piston Packing ....................................................... 69
--Combination Steam Hammer Packing .................... 70 --Rod & Plunger Packing ................................................. 72
Standard Flanged Fittings, Radiation area of .........255
V
Standard Hair Felt ....................................................................100
Valves, Rubber Pump ................................................................ 90
Steam Hammer Packing, Universal Combination ... 70
Ventilators, Transite Asbestos Wood .............................. 199
Steam Leakage, Losses due to ...........................................252
Vitribestos Sheets and Blocks ............................................ - 46
Steam Pipe Insulation, Minimum Thicknesses of .. .253
Vitro Fire Felt Sheets and Blocks..........................
45
Steam Traps ...................................
HO Volume of Water at VariousPressures ............................253
Steam Tables (Marks') .................................................. 249-252
Volume Meter ........................................................
Steel Passenger Car Insulation-
92
Steel and Wrought Iron Pipe, Data on ....................254
Stone Backing, Cut ......................................................
223
Story of Asbestos ......... ..:................................ 6
w
Walls'and Ceilings,'Transite Asbestos Wood,
Details of................ . : ,
...............191-192
Stove Lining, Phoenix Asbestos ................ .................... 60 . . Wall Coating,'. Boiler, Aertite ........................................ ..;. 59
Strip ShingleSj Flexstone Asbestos ...............
179-180 ; Wall,1 Monolithic Baffle
.........................................,58.
... Success :Fire;.Extinguisher,./Automatic Type .......245-
Wall Siding, As'oestosid'e Y...............,........................... .. 146,
v Success pire. Extinguisher; Non-Freezing: .................. 245 ... Washers, Union.
........................................ 90.
' Superb-Refractory-Cements,-Nos. 33 and 35 ............... 56'
Water Gauge Gaskets ........... ......................... ........................ 89
. Waterproof: Coating,- Liquid .....................................: 223
Table of Data.on Wrought Iron: and Steel Pipe ....254.
--Decimal--Equivalents .........................................................256
--Fahrenheit :ahd': Centigrade Conversions ;............258
. --^Metric Conversion .
..258
--Losses dueFoYSteam Leakage ............
252
. . --From-.Bare; Surfaces
.Vr............................ .. . 249
--Steam. .'-v'.
....
. . . . : .249
Tank Car Insulation: ..... :...........
101
Tape, Friction :vv\Y.'.....':.................................................. 241
.Tape, Kearsarge Asbesto-Metallic Gasketing ............. 87
Technical Data, Refractory Cements ............................... 57
Temperature Conversion Tables. ........................
...258
Test on Roofing,. Underwriters ........................................... 120
Thermo Fire Felt Sheets and Blocks ............................. 44
--Efficiencies .of ..................
48
--List Prices ............................................................................ 49
Thickness of Steam Pipe Insulation, Minimum ..........253
Third Rail Covering ............................................................... 244
Throttle Packing, Kearsarge ......................
81
Top Head and Bottom Head Gaskets for Air Pumps 90
Train Pipe Insulation, Asbesto-Sponge Felted.......... 11
Transite Asbestos Wood (flat)
--(Building Purposes) ......................................................... 188
--(Electrical Purposes) .................................................... 230
--Caps and Stacks .................................................................. 199
, Waterproofing.
:-
--Cement, -Asphalt'. -...........................
221 '
--Self-Healing .Y. .. ..................'..............222.
. --Felt;. Asbestos .
...221
. . ..Water Volume at Various Pressures ................
253
..Weights Corrugated Asbestos Roofing & Siding;
. Asbestos -Protected Metal :... . ................................. 163
.Weights and List Prices
--Ebony-Asbestos Wood . ...........................................229
--Transite Asbestos Wood .......................................... ..230
--Sheet '& Block Insulation. ........................................... .. 49 --Sectional Pipe Insulation ............................................. 32
Westinghouse Air Pumps, Packing for ........................ 80
White Top Asbestos Ready-to-lay Roofing ............... 143
Wick and Rope Packing, Asbestos .................................... 73
Wood, Ebony Asbestos .........................................................228
Wood, Transite Asbestos (fiat) ......................................... 188
--for Electrical purposes .................................................. 230
--Smoke Jacks ................................................................ 193-198
--Stacks and Caps .................................................................. 199
--Ventilators ..............................................................................199
Wool Felt Sectional Pipe Insulation ............................... 31
Wrought Iron and Steel Pipe, Data on............................254
z
Zero Sectional Pipe Insulation ............................................. 31
264
CRMC-003628
116-