Document NEY8eq4xe7jkeqJgZ8Vq0OR9y
S8F9 89 A3H0
%
if**
_ _____ _____
TYPICAL ANALYSIS DATA
PLAINTIFF'S EXHIBIT CHV-51I
PRODUCT:
... PANELEX T.P.
DESCRIPTION:
NON-ASBESTOS, ULTRALIGHT, HIGH-STRENGTH, INSULATION-
SPECIMEN TYPES:
I GUNNED
RECOMMENDED SERVICE LIMIT:
2000F
P.C.E.:
CONE 5 (2230F)
ASTM CLASS (C-401):
CLASS "0"
WATER REQUIRED TO CAST 100 LBS MATERIAL:
N/A
MATERIAL REQUIRED TO GUN 1 CU. FT. :
* 28 TO 32 LBS
RECOMMENDED PRE-WET PER 100 LBS. (GUN) :
IQ TO 1.5% CBY WEIGHT!
PACKAGING:
50 LB BAG
APPLICATION METHODS:
TROWEL, CAST, GUN, PUMP
CHEMICAL ANALYSIS
Si2 ai2o3 Fe23 CaO MgO
T102 Alkalies
as Na20 L.O.I.
41.83 12.96
2.75 26.86
6.39 .33
3.05 5.83
THERMAL CONDUCTIVITY (BTU/FT2/HR./F/IN.')
MEAN TEMP.
"K"
500 1000 1300
.80 1.15 1.27
PHYSICAL PROPERTIES:
Fired to F
220 500 1000 1500 2000
Density Lbs/cu.Ft.
25.4 26.027.1 26.5 25.3
Linear Change %
0.0 -0.2 -0.6 -1.0 -1.7
Modulus of Rupture, psi -
154 150 135
84 45
Cold Crushing Strength, psi
294 289 ' 287 186
84
* NOT INCLUDING FIELD WASTE NOTE: ASTM TEST METHODS USED WHERE APPLICABLE
375C4Q6G1 C873 Rev.i
INFORMATION GIVEN AND RECOMMENDATIONS MADE HEREIN ARE BASED UPON OUR RESEARCH ARE BELIEVED TO BE ACCURATE. BUT NO GUARANTEE. EITHER EXPRESSED OR IMPLIED. IS MADE L RESPECT THERETO OR WITH RESPECT TO THE INFRINGEMENT OF ANY PATENT. OUR PRODUCTS
ni iir-i rv rniin*'iv mo
Hi
9Efr9 8a A3H0
THERMAL CONDUCTIVITY - PANELEX TP (Gunned)
CONDUCTIVITY FACTOR - (BTU/FT 2/HR/ F/IN)
HOT FACE TEMPERATURE
MEAN TEMPERATURE ( F) * PERFORMANCE GRAPH - PANELEX TP (Gunned)
BTU LOSS (FtVHr)
COLD FACE TEMPERATURE
`THESE CURVES ARE BASED ON STILL AIR, 80 F AMBIENT TEMP AND EM1SSIVITY FACTOR OF 0.9
REFRACTORY A N D CONSTRUCTION ANCHORS