Document NEXpGdp5exz8QLNrQggjde7bg

--AT,NC ^^ilating ^^"conditioning guide~iqaa~ thinner wall and, in the small sizes, its freedom from the occasional tendency of welded pipe to split at the weld when bent. Wrought-Iron Pipe. Wrought-iron pipe is claimed to be more corro sion-resisting than ordinary steel pipe and therefore its somewhat higher first cost is said to be justified on the basis of longer life expectancy. Wrought-iron pipe may be identified by the spiral line marked into each length, either knurled into the metal or painted on it in red or other bright color. Otherwise, there is little difference in the appearance of Table 1. Dimensions of Schedules 30 and 40 and Standard Weight Pipe __ |j f--i 1 Diameter In. Weight per I Ft, Lb Transverse Area. Sq In. Length op Pipe, Ft I per Sq Ft t [Length op Pipe, 1 Weight Ft op . CON- I PAINING Water, Lb ICoFt per Ft A I 0.405 0.540 . 0.675 ' OMO 0.269 0.3641 aiosi0.493 .0.091 0.6221 0.244 0.424 0.567 0.850 0.245 27 0.425 18 0.568 18 0.852 14 1.050 1.315 1.660 1.900| 0.8241 1.049 1.330 1.610 1.130 , 1.678 , 2.272 I 2.717 1.134 14 1.684 2.281 2.731 2.375 2375 3^1 3.500 4.000 ' 4.500 I 5.563 6.625 I 8.625 8.625 2.067 0.154 2.469 a203 3.068 0.216 3MS a226 3.652 5.793 7.575 9.109 3.678 5.8191 7.616 ,, 93021 8 4.___ ,0.237 5,047| 0.258 10.790, 14.617 10.889 14.810 8 8 6.065 ft280 18.974 19.185 8 8.071 0.277 24.696 25.000 8 7.981 0*322 28.554 28.809 8 ) 10.136 [0^07 34.240 35.000 8 0.129, 0.229 0358 0.866 1.358 2.164 2.835J (L304 4.430, 6.492j 9.621 12.566 , 15.904 , 24.306 34.472 I 58.426 12.730 20.006 28.891 51.1611 58.426 150.027 SI . 14.199 2533.775 H 10.493 1383.789 " 7.748 754.360 6.141 473.906 0.025 0.045 0.083 0.132 0.333 0.494 0.669 0.799 3.637 4.635 2.904 3.641 2-3011 2.768 2.010) 2372 l.t , U28 1 1.091 0.954 1.847 1-547 1345 1.076 270.034 166.618 96.275 70.733 42.913 30.07^ 19.47) 14.565 0.231 0.375 0.65 038 1.45 2.07 3.20 4.29 3.174 0.848 0.948 4-300J 0.686 0.7561 5-5Sl| 0.576J 0.6291 11.312 5.50 7.198 8.67 4.984 12.51 0.4731 ft478 2.815 22.18 2378 21.70 ) 10.020, 0.365 40.483 41.132 8 > 12.090 t 12.000 3 45.000 8 2 50.706 8 ^ - T- 40.055 37.982 127.676 114 800 *0.055 37.699 127.676 113.097 0^5510.072 0.355 0.376 11.908 0.381 12.876 0.2991 0.315, 14.579 0.299 0318 1.785 34.95 1.826 34.20 1-254 49.70 1.273 49.00 *Staudard-weight wrought-iron pipe 1 ____ _____ _ _tiu_*aicsses ana weights as contained herein for steel pipe. For exact dimensions, seeAmerican Standardfor Wrought-iron and WroughtSteel Pipe, AS.A. B36.10. B36^.T1h0.icknesses shown in bold face type are identical with thicknesses for Schedule 40 pipe of AS.A. cSame as Schedule 30, A.SJL. B36.10. wrought iron and steel pipe, although microscopic examination of polished and etched specimens will readily disclose the difference. Cast-Ferrous Pipe. There are now available several types of castferrous metal pipe made of a good grade of cast-iron with or without additions of nickel, chromium, or other alloy. This pipe is available in sizes from V/2 in. to 6 in., and in standard lengths of 5 or 6 ft with external and internal diameters closely approximating those of extra strong wrought pipe. Cast-ferrous pipe may be obtained coupled, beveled for welding, or with ends plain or grooved for the several types of couplings. It is easily cut and threaded as well as welded. The fact that it is readily 324 CHAPTER 17. PIPE, FITTINGS, WELDINC welded enables the manufacturers to supply the pipe in any lengths practicable for handling. Alloy Metal Pipe. Steel pipe bearing a small alloy of copper or other alloying element and iron pipe bearing a small alloy of copper and molyb denum have been claimed to possess more resistance to corrosion than plain steel pipe and they are advertised and sold under various trade names. Copper Pipe and Fittings. Owing to its inherent resistance to cor rosion, copper and brass pipe have always been used in heating, venti lating, and water supply installations, but the cost with standard dimen sions for threaded connections has been high. The recent introduction of fittings which permit erection by soldering or sweating allows the use of pipe with thinner walls than are possible with threaded connections, thereby reducing the cost of installations. The initial cost of brass and copper pipe installations generally runs higher than the corresponding job with steel pipe and screwed connections in spite of the use of thin wall pipe, but the corrosive nature of the fluid conveyed or the inaccessibility of some of the piping may warrant use of a more expensive material than plain steel. The advantages of corrosionresisting pipe and fittings should be weighed against the correspondingly higher initial cost. COMMERCIAL PIPE DIMENSIONS The two weights of steel and wrought-iron pipe commonly, used are known as standard weight and extra strong, which correspond to Schedules 40 and 80 respectively of the American Standard for Wrought-iron and Wrought-Steel Pipe, A.S.A. B36.10. The same external diameter is used for both weights of each nominal'size for manufacturing reasons as well as to afford interchangeability in threading, and other elements associated with fabrication and erection. Hence the difference in wall thickness is accompanied by a corresponding change in inside diameter. In sizes up to 14 in., pipe is designated by its nominal size which, corresponds roughly to the inside diameter of Schedule 40 pipe. In sizes 14 in. and upward, pipe is designated by its outside diameter (O. D.), and the wall thickness is specified. While the demands for pipe for the heating and ventilating industry are reasonably well served by Schedule 40 (standard weight) pipe, the erection of pipe by welding sometimes warrants using lighter wall thicknesses. The considerations governing pipe wall thickness and its relation to joint design are covered in the American Standard Code for Pressure Piping, A.5.4. B31.1-1942, see Section 122. Standard schedules of pipe thick nesses are contained in the American Standard for Wrought-iron and Wrought-Steel Pipe, A.S.A. B36.10, which includes standard-weight and extra-strong thicknesses in Schedules 40 and 80,-respectively, and eight other schedules of varying wall thickness to provide for different service conditions. Dimensions and other useful data for Schedules 30 and 40 pipe are given in Table 1. Table 2 from A.S.T.M. Specifications A53 and A120 combines the schedule thicknesses of A.S.A. B36.10 and the old series designations. Standard-weight pipe is generally furnished with threaded ends in random lengths of 16 to 22 ft, although when ordered with plain ends, 325