Document NEVLz28Md57rn7Kz8R997rEz8

TOWOLDMON0021697 WATER_PCB-00006166 CONTENTS Page Intioduction Compressor Fires & Explosions stable 1, Physical Proxies and Viscosity ble 2, Vapor Prod Page 4. Figure 1, Specifi/Heat Figure\2, Specific Gravity Plot Figure k Twfical Viscosities Page 5. F*ydraul FlrXResislance Page 6. Elimination of\Valve Deposits Page 7. Converting to Pydraul Lubrication Qualify Table 3, Film Strength /Table 4, Wear Under Continuous Lead Table 5, Timken (Extreme Pressure) Table 6, Shell rour-Ba\wear Table 7, Pump Test Mixing Compatability / Table 8, Pydraul with Other tf^drautic Fluids Page 10. Major Air Compressor Manufacturers Using Pydraul < Page 12. Safe Handling J I (jOoB'ibl TOWOLDMON0021698 WATER_PCB-00006167 The PYDRAUL Air Compressor Fact Finder ... is designed to make Die many facts and features about Pydraul fire-resistant lubricants for air compressors quick and easy to find. We hope you will /md it helpful in working with these safely lubricants for air compressors--Pydraul AC, Pydraul AC Winter Grade 28, and Pydraul 625. Special safety lubricants for air compressors provide three important advantages over petroleum oil: safety from fire and explosion, virtual eliminat ion of valve deposits, and lower maintenance costs. By eliminating combustible mists and minimizing carbonaceous residues, Pydraul lubricants reduce the threat, of compressor fires and explosions. Pydraul lubricants also reduce compressor main tenance costs. By eliminating deposits on exhaust valves, in coolers, and in piping, these lubricants greatly reduce the costs of compressor down-time and cleaning. These lower maintenance costs alone usually justify using Pydraul lubricants for air compressors. For air compressors which operate in low ambient temperatures, Pydraul AC Winter Grade 28, a low temperature lubricant, is recommended. Pydraul 625 is recommended for compressors requiring a high viscosity lubricant. 0oa*ae TOWOLDMON0021699 WATER_PCB-00006168 How Compressor Fires & Explosions May Occur There areseveral theories concerning the mechanisms of fires and explosions in air compressor systems, blit, one point is common in every case: petroleum oil lubricants are directly involved. Mist and accumulated films from petroleum oil in compressor systems can, under a variety of con ditions, break down into combustible gases and carbonaceous residues that can ignite and produce an explosion, a receiver fire--or both. The U. S. Rureau of Mines1 found that carbon deposits in air compressors lubricated with petroleum oil form a "carbon-oxygen complex." Oxidation forms this complex, and accelerated by heat, this oxidation process can load to an explosion. Safety devices do not completely eliminate fire and explosion possibilities. A recent study on "The Mechanism of Explosions In Starting Air Lines/'2 based on an exhaustive survey of compressor opera tions at 53 companies, reports that, a stuck or leak ing air check valve permits the engine being started to pack the section of line between the check and air timing valve with an explosive "oil residue-air" mixture. A pressure wave will force this mixture upstream into the main air line-- and coupling this with good flame propagation in tin: power cylinder, the condit ion is laid for explosion in the pipe system. Air line explosions and fires may even occur with out the engine being started or before the ignition is turned on.2 Carbon and rust, particles in a "hot" air line, due to operat ing an overheated compressor too long--hardly an improbable condition--can be come saturated with oil, and witli the flow of start ing air, can cause these oil-saturated particles to flame. The Walter Kidde Company, makers of fire ex tinguishing equipment, warns in a study3 that users of high pressure air should guard against int roducing a shock wave into high pressure linos by suddenly opening a plug cock in air compressor systems using petroleum oil. This report showed that in a 1-ineh diameter tube, the inside walls filmed with oil, a sudden admission of air at pressures above 1300 psi caused combustion. The variety of fire and explosive conditions that may occur in air compressors lubricated with petro leum oil are many and unpredictable. This danger and unpredictability raises the need for eliminating the source of carbon deposits, the basic cause of most air compressor fires and explosions. Fire- and explosion-resistant Pydraul air compressor lubricants essentially eliminates this basic cause: by minimizing carbon deposits. Their superior oxida tion resistance adds to their ability to prevent ex plosions. And by their inherent ability to resist burning in air, Pydraul lubricants substantially reduce the threat of fire. 1. "The Carbon Oxygen Complex as a Possible Initiator of Explosions and Formation of Carbon Monoxide in Com pressed Air Systems," by Busch, Berger, and Schrenk, Bureau of Mines paper RJ.4465, June 3949. 2. "The Mechanism of Explosions in Starting Air lines," by Ridgway, Robert $., Petroleum Refiner, June 1958. 3. "Oil Combustion Phenomena in High Pressure Air Systems," M. W. Weibel, Walter Kidde & Co., Inc., Report R-831, copyright 1952. 2 TOWOLDMON0021700 WATER_PCB-00006169 TABLE1 COMPATIBILITY WITH METALS Pydraul air compressor lubricants are compatible with all construction metals including aluminum. In most operations, aluminum bearing surfaces that have been anodized will wear as long as any other metal bearing lubricated with Pydraul lubricants. ) , : . Vapor Density- 11.2 compared to value for air of one (1). 0068*8* TOWOLDMON0021701 WATER_PCB-00006170 TOWOLDMON0021702 WATER_PCB-00006171 PYDRAUL Fire-Resistance I'ydraul fire-resistant fluids and lubricants have worked in industry since 1951, providing many millions of machine hours of fire-free operation. Never during these hours of ' machine operation has a Pydraul fluid contributed to a fire--and never since its introduction in 1954 as a fireresistant compressor lubricant has l'ydraul AC caused an air coni]'lessor fire. FIRE-RESISTANCE TESTS OF PYDRAUL AC TEST \ | RESULTS' High Pressure Spray Test AMS3150C and Federal Test Method Std. 791. Test fluid sprayed^at 1000 psi through orifice, passing through flame of oxyacetylene, torch, 6000F. Does not flash or ignite up to 31/? feet from orifice. Low Pressure Spray Test (AMS3150C). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of in crease in flame intensity. -Very slight id- crease in flame intensity. 1 Hot Manitold Test (Federal Test Method Std. 791). Test fluid/ dripped on tube at 1300F. Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 120CPF., to test for spontaneous ignition. Results are the same for Pydraul 625 and Pydraul AC Winter Grade 28, TOWOLDMON0021703 WATER_PCB-00006172 PYDRAUL AC Virtually Eliminates Valve Deposits Compressor Data: 142 CFM, 6" LP Bore, 5" HP Bore, 5" Stroke, 870 RPM, 100 psi air The^phtJtos compare exhaust valve deposits formed ^-during individual 500-hour operations on two lubri cants: a premium grade petroleum oil . . . and Pydraul AC*. A glance at the photo of the valve lubricated with petroleum oil shows considerable carbon deposit build-up after 500 hours operation. The improve ment in the valve condition in the photo on the right is obvious--virtually no carbon deposits after 500 hours operation with Pydraul AC. In the particular case, the compressor operator expects to get 7500 to 10,000 hours of service from Pydraul , AC without shutting down--a 15- to 20-fold in crease in operating time without a shutdown, liesuit: substantial maintenance savings in time and I money--and virtual elimination of the fuel source j of most air compressor fires and explosions. No photographs available of Pydraul 625 and Pydraul AC Winter Grade 28, but results are at least identical. O0faB`>87 TOWOLDMON0021704 WATER_PCB-00006173 Converting To oy PYDRAUL ^ Is Easy from air streams. A Monsanto development, a Brink mist eliminator is a particularly effective system, available from Monsanto in a series of lowcost mist eliminator systems to operate at all capacities. For information on a Brink series suitable for your compressor system, write to: ) Monsanto Engineering Sales Department t .* First, simply drain the petroleum oil and wipe the crankcase or lubricator. Thoroughly clean the exhaust valves and interstage equipment before filling the crankcase or lubricator 800 North Lindbergh Blvd. St. Louis, Mo. 63166 Telephone: (314) 694-2286 (Joseph A. Brink) with Pydraul. Pydraul will loosen carbonaceous deposits, varnishes and sludge. Unless these loosened SPECIAL CHECK FOR deposits are denned from the system, they could SPLASH-LUBRICATED COMPRESSORS clog pipelines and components, requiring additional downtime and production loss. Once the valves have been thoroughly cleaned of potentially dan gerous carbon deprxsits, Pydraul lubricants will keep them clean- and let compressors run longer between maintenance shutdowns. Crankcase paint.Pydraul air compressor lubricants will soften and loosen some paints from crankcase interiors. These paint particles could block the lubri cant passages. For this reason, it is a good practice to remove paint from crahkcase interiors before Pydraul is added to the system. Standard paint removers are adequate for removing this paint. STANDARD CHECK FOR COMPRESSORS-Plastic separator bowls. SPECIAL CHECK FOR FORCE-FEED LUBRICATORS Not all plastic separator bowls are suitable for Pydraul service. Certain plastics are "crazed" or softened when exposed to Pydraul. Bowls made of glass, brass, steel, and these plastics--polycarbon ate, polyethylene, or nylon--are recommended for use with Pydraul. If you have a question regarding the resistance of a particular plastic, Monsanto will be happy to advise you. Sight-glass fluid. If a separate forcc-feed lubri cator of the type normally filled with water and glycerine is used, one of two changes is necessary: either replace the sight-glass fluid with one heavier than Pydraul or insert a metal bobber in the sightglass. Pydraul fluids are heavier than water or glycerine and will not rise through these standard sight-glass liquids. Fluorochemical 101, a clear liquid Diaphragm valves. Pydraul lubricants have a sof tening effect on neoprene and buna N rubber diaphragms normally used for petroleum oil service. These diaphragms should be replaced with butyl supplied by the Minnesota Mining and Manu facturing Company, has a higher density than Pydraul and is a completely satisfactory replace ment. 1` \ ^ rubber, EPR (ethylene propylene rubber), fluoroelastomer, silicone or other compatible elastomer materials resistant to Pydraul fluids. Diaphragm sheeting is available from normal sources of supply. Metal bobbers. The alternate to using Fluoro chemical 101 is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, remov All diaphragms in unloading valves or downstream ing the guide wire and inserting the bobber. Opera control valves should be replaced at the time of tion of the lubricator is then indicated by movement changeover. Diaphragms in valving downstream of the bobber with each stroke of the pump plu nger from separator systems or drying systems need not instead of counting the drops as with guide wires. be replaced at changeover time, but should be Bobbers are available for either McCord, Mansell, changed on a preventative maintenance schedule or Lincoln Engineering lubricators. Modification of as soon as practicable after operation on Pydraul the Madison-Kipp lubricator requires replacement is begun. of the entire sight-glass. For air compressors supplying air for instrumenta tion functions, mist eliminator systems are rec Vacuum-sight lubricators. Vacuum-sight lubrica ommended to remove lubricant mists and moisture tors require no modification for Pydraul usage. " || i ( ' 0066468 TOWOLDMON0021705 WATER_PCB-00006174 PYDRAUL Provides The Lubricating Qualities Of Premium Petroleum Oil Long years of service in air compressors of almost every type have proved the lubricating qualities of Pydraul air compressor lubricants equivalent to those of premium petroleum oil. 1 I'ypical are the statements below from eng porting the performance of Pydraul as a lubricant. "Lubricating properties of Pydraul AC/have been very satisfactory.'Wear measurements on Molypak rings taken approximately five/months later indicate 0.003" wearV This is normal and con sidered very good. No corrosion hi cylinder liners, valves and piping has Deen/experienced, and service is very satisfactory) /Compfi ssor equipment: Cooper^- Bessemer JM5 "Pydraul AC--outside of reducing the fire hazard --also providesvery satisfactory lubricatiorNand protection of yalves ... It seems rather logica\to assume that'the complete absence of deposit! due to progressive oil oxidation and consequent high temperatures, shall help improve valve per formance! and maintenance, The higher gravity of Pydraul seems to result in better mechanical separ/tion, and its water like permanent clean liness does not interfere with the cleanliness of surfaces contacted." ' Compressor equipment: Joy Manufacturing WN-11 ? E TOWOLDMON0021706 WATER_PCB-00006175 Lubricating Qualities TABLE 3 FILM STRENGTH JAW LOAD (LBS.) TORQUE (LBS. INCHES) Pydraul 625 Pydraul AC Pydraul AC Winter Grade 28 4100 3600 3700 89 98 92 TABLE 4 WEAR UNDER CONTINUOUS LOAD lsl 10 MINUTES 2nd 10 MINUTES Pydraul 625 Pydraul AC Pydraul AC Winter Grade 28 0.000618 0.000428 0.000450 0.000332 0.000285 0.000330 TABLE 5 TIMKEN (EXTREME F>RES$URE)* Pydraul 625 Pydraul AC Pydraul AC Winter Grade 28 21.200.psi 23,250 psi 18,000 psi film strength--'Typical Petroleum Oil (measured by Timken 1 xtremc Pressure)--5,000 to 8,000 psi. TABLE 6 SHELL FOUR-BALL WEAR (167?., 1 hour, 630 rpm., mm scar diameter) STEEL ON STEEL PYDRAUL 625 PYDRAUL AC WINTER GRADE 26 10 kg 40 kg 0.26 0.62 0.32 0.70 0.30 0.65 TABLE 7 PUMP TEST* (Vickers V105E., 140*F,, 1000 hours.) PYDRAUL 625 PYDRAUL AC Ring, grams (loss or gain) -0.0013 Vane, grams (loss or gain) -0.0015 Bushing 2015 grams (loss or gain) -0.0045 Bushing 2016 grams (loss or gain) -0.0050 -0.0076 4 0.0014 4 0.0040 4-0.0045 No data is presently available on Pydraul AC Winter Grade 28. /v DROP SIZE Drop size of a lubricant is important to determine an adequate lubricant injection rate to insure proper compressor lubrication. The rate of lubri cation is controlled by noting the drops per unit of time. The drop size for the fluids tabulated below were determined by noting the number of drops formed at room temperature (75F.) on a 1 mm I.D. by 3y2 mm O.D. glass tip. (Larger or smaller drops will result if different sized tips are used.) Medium weight petroleum oil Pydraul AC Drops per cubic centimeter 33 39 OO68490 TOWOLDMON0021707 WATER_PCB-00006176 PYDRAUL Is Used As t) A Lubricant For Air Compressors Made By All Major Manufacturers o Mixing Compatibility New air compressors of most types and sixes pro duced by major compressor manufacturers can be manufactured for lubrication with Pydraul. The manufacturers listed (right)have manufactured com pressors equipped for Pydraul, upon specification of the buyer, for over ten years. Many compressors have operated on Pydraul lubricants continually with exhaust air temperatures of 350F. Pydraul is also used to lubricate cylinders in compressors operating at pressures over 4500 psig. TABLE 8 PYDRAUL WITH OTHER HYDRAULIC FLUIDS FYRQUELteb1?) 90 150 220 300 550 HOUGHTO-SAFE 1010 1055 1120 1130 625 YES YES YES YES YES AC AC-WG28 YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES oo`>8',,,V TOWOLDMON0021708 WATEFLPCB-00006177 0^ American Messer Corporation Bury Compressor Company Carrier Corporation Chicago Pneumatic Tool Company Clark Brothers Company, division of Dresser Industries Cooper-Bessemer Corporation DeLaval Steam Turbine Company Gardner-Denver Company Ingersoll-Rand Company Joy Manufacturing Company Kinney Manufacturing, division of The New York Air Brake Company Norwalk Company, Incorporated Schramm, Incorporated Worthington Corporation I i '"When installing new equipment, it is best to start with an increased lubricant feed rate and reduce this rate by successive increments. Inspection of cylinder walls and valves will indicate the proper degree of wetting. ~p irvu,\ A 3 l t {, p| 0068492 | TOWOLDMON0021709 WATER_PCB-00006178 T Safe Handling I There has been no reported ease in many years of service to indicate any special health hazard with Pydraul air compressor lubricants. However, as with all specialized industrial fluids, certain pre cautions are advisable. Skin contact. Jtepc.at.ed or continuous skin con tact with Pydraul fluids should be avoided. Pydraul fluids act as a solvent and repeated or prolonged skin contact can cause dry skin and chapping. Eye contact. Although eye irritation studies using Pydraul fluids at full strength indicate Pydraul to be an irritant, there is no evidence to show Pydraul causes permanent eye tissue damage. If Pydraul fluids are splashed or sprayed into the eyes, mod erately severe pain and irritation may result. Kyes should be thoroughly flushed with water and the workman referred to a physician. To relieve irritation, physicians have used 1% pontocaine solution, as well as the ophthalmic cortisone acetate solution. Vapor inhalation. At room temperatures, there is no vapor inhalation hazard from Pydraul fluids. Although there has been no problem with high con centrations of vapors, inhalation of vapors at high temperatures should be prevented. Air samples were taken from the line of a doy Manufacturing air compressor which had operated on Pydraul AC for three years. Filter paper and silica gel samples were collected and analyzed using a Beckman Spectrophotometer after iso-octane or iso-propanol extraction. No concentrations of the major components of Pydraul AC could be detected. No serious hazard is anticipated from vapors of Pydraul fluids; however, if the compressed air is to be used for air line masks, respirators, and other inhalation equipment, it- is always recommended that a commercial filter cartridge for air-supplied masks be incorporated in the compressor air line to remove any foreigj) matter. This is simply good industrial practice for any compressor fluid or lubricant. 1? OObB*93 | TOWOLDMON0021710 WATER_PCB-00006179 DISTRICT SALES OFFICES ALL DIVISIONS ATLANTA, GEORGIA 30326 Lenox Tomrs East 3400 Peachtree Rd. N. E.--Suite 1711 Tel. (404) 577-2260 BOSTON, MASSACHUSETTS 02149 Evorott Station Tel. (617) 387-5010 CHICAGO, ILLINOIS 3J58 Des Plaines Ave. Dos Plaines, (ftirois 60018 Tel. (312) 296-6688 CINCINNATI, OHIO 45206 1501 Madison Road Tel. (513) 751-6707 CLEVELAND, OHIO 44122 3645 Warrensville Center Rd. Tcl. (216) 991-5400 DETROIT, MICHIGAN 48235 500 Northland Towers East Tel. (313) 357-0910 HONOLULU, HAWAII 96812 205 Pacific International Bldg. 677 Ala Moana Blvd., P. 0. Box 3824 Tel. (808) 512-744 ^ HOUSTON,TEXAS 77002 1300 Main Street ' Tel. (713) 223-4011 LOS ANGELES, CALIFORNIA 90022 6670 E. Flotilla Sf. To/. (213) 723-2492 MINNEAPOLIS, MINNESOTA 55402 9J2 Northstar Center 110 S. Seventh St. Tel. (612) 339-4651 NEW YORK. NEW YORK 10017 277 Park Avenue Tel. (212) 922-4111 PITTSBURGH, PENNSYLVANIA 15222 No. 4 Gateway Center Bldg. Room 534 Tel. (412) 261-2156 ST. LOUIS, MISSOURI 63166 800 N. Lindbergh Blvd. Tel. (314) 694-1000 SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara, Calif. 95052 Tel. (408) 243-0414 SEATTLE, WASHINGTON 98104 911 Western Avenue Tel. (206) 622-4203 SPRINGFIELD, MASSACHUSETTS 01101 730 Worcester Ave. Tel. (413) 788-6911 WILMINGTON, DELAWARE 19803 2005 Concord Pike, Fairfax Tel. (302) 658-6531 ft V "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCTS REFERRED TO. no iuarantee of satisfactory results from reliance upon contained information or recommendations, and disdain" liability for any resulting loss or damag^. PYDRAUL (Monsanti TOWOLDMON0021711 WATER_PCB-00006180 F 06849s Monsanto FUNCTIONAL FLUIDS Monsanto Company, 800 North Lindbergh Blvd., St. Louis, Missouri 63166 TOWOLDMON0021712 WATER_PCB-00006181