Document NEV7EnX4aYpndpvremoXGBQ3b
Air Conditioning ^,TMaFtl>e^u-ii,ment: d Heaters, Unit Heateri>
Lee Corporation
%
Foot of Madison Street, P. 0. Box 1801, Wilmington, Delaware M
Baltimore, Mo.
.
NewYork, N. Y.
. Chicaoo, III'^
Representatives hi all Principal Cities
Manufacturers and Designers of Complete Line of Industrial and Commercial Warm-
Air Heaters
il
MODEL HD--750,000 to 2,000,000 Btu MODEL TSE--2,000,000 to 8,000,000 B$1 MODEL VTH--2,000,000 to 6,000,000 Btu MODEL BST--2,000,000 to 10,000,000 B0
LEE HEAVY DUTY HEATERS
& LEE HEATERS have been in continuous;'
operation since 1918. Lee Heater install
lations have been made in most of the'
States of the United States, in Canada,"
Alaska, Yukon Territory, Northwest
Territory, Labrador, Iceland, Norway,
Mexico and South America.
Firing Equipment manufactured spe
cially for us by leading Companies with
International service organization.
There is a Service man near you if and
when you require assistance. In addi
tion Lee maintains a competent field
serving staff.
Replacement and Spare Parts Service
Lee Direct-Fired Space Heater Model hd
760,000 to S,000,000 Btu
is maintained. Most items are carried in
stock. VERSATILE
Types of Fuel
Light Oil (# 3 or Lighter) Medium Oil (#5 or Lighter) Heavy Oil (# 6 or Lighter) Gas (Natural, Manufactured Propane,
Coke Oven.)
Combination Light Oil & Gas Combination Heavy Oil & Gas
Mount in any Position
. Floor-Mounted Horizontally Mounted (& Suspended)
Vertically Mounted (& Suspended) Use with Ducts for Central Heating System Use without Ducts as Self Contained Heating System
Output Capacity (Btu per hr) Total Heating Surface in Sq Ft Cu Ft of Air per Min. (Approx.)* Air Fan Motor h.p.
Induced Draft Fan Motor h.p. External Static Pressure (Std.) Maximum External Static Pressure Avail
able for Duct Work** Temperature Rise-Degrees F, Fuel Consumption***
Gas (cu ft per hr) Oil (gal per hr)
Shipping Weight-lbs Refractory Comb. Chamber Stainless Steel Comb. Chamber
Heater Length Heater Width Heater Height Number of Outlets Number of Blowing Fans
HD-750
750,000 175
8,500 5 H H' 1'
82
940 6.5
5000 3100
4'0' 9'11'
3 2
,HD-1000 HD-1250 HD-1500 HD-1750 HP-200
1,000,000 1,250.000 1,500,000 1,750.000 2 000,000
192 218 260 328 363 *
11,000 5
14,000 7H
17,000 7H
20,000 10
.22.000 15
HH HH
H' H' H` M'
1' 1' 1' H*
80 83 82 81 84
1250 1560 1880 2190 2500 8.6 10.8 13.0 15.0 17.2
5300 3400
7'-lH' 4'0' 9'11'
4 2
5800 3800
8'3' 4'0* 9'11'
4
3
7000 4700 8'-4H' 4'4'
ll'-3Hr 4 2
8600 6300
8'-4H' 4'4' ll'll'
4 2
0400 7000 ` 9MH' 44'
wn' 4
* Based on Standard Air at 70 F Free Delivery
** Requires large Air Fan Motor *** Fuel consumption based on 1000 Btu per cu ft of Gas, 145,000 Btu per gal of Oil and .on ! l percent efficiency for the heater.
100
Air Conditioning SXlS
Mammoth Furnace Company
6452 Cambridge Street Minneapolis 26, Minnesota
Strong-built for rugged service and safe shipment. Quiet Fan Operation--a rigid tubular fan shaft supported by two self aligning
bearings eliminates shaft and bearing problems. Retractable Burner Tray--allows com plete service to burner. Permits removal
from unit with no disassembly and mini mum handling.
Central Control Cabinet--provides con trols, fusing and wiring in an accessible
dust-tight enclosure.
Direct Driven Induced Draft--troublefree, vortex cooled motor shaft connec
tion io blower wheel. No belts arid addi tional bearings to service.
Variety Of Controls And Power Supplies
--units may be "off-on" thermostat con trolled, hiJow fire or modulated control.
Wiring and controls can be provided for
all power supplies. Integrated Burner Applications--burners
by reputable manufacturers are tailored to produce the most effective flame con
figuration for the heater design. Combustion Safety And Draft Controls--
MH-Electronic flame control system,
pre-ignition draft purge timing and draft
sensing give a high degree of operation
safety.
., ,
Series "F" Floor mount with discharge
heads for industrial plants, foundries,
Series "H" Horizontally suspended unit
for use where floor space is unavailable. Series "FD" For duct distribution. For churches, schools, auditoriums, etc. Series "U" Suspended inverted unit for make-up air applications in plants,
foundries, etc.
SPECIFICATIONS
Length! W idth Plenum
Opening Approx.
Shipping W e ig h t
Model
Btu Output
Sq ft Htg.
Sag
Sur <jeS
face B.D.T.
aSs
o
Blower DIDW
Motor hp
KO
eae-
a.* at* <
Max Firing Rate
Oil Gas gph cfb
300 300,000 135.3 4,000
n 575 3.0 375 60*
550
<00 800
400.000 135.3 5,500 550,000 183.6 7,000 700,000 183.6 8,700 800,OOC 276.8 10,000
i 640 1H 750 2 820 3 710
4.0 500 5.0 688 7.0 875 7.5 1.00C
60'
80' 80'
80'
1,000.000 276.8 13,000
5 790 9.5 1.25C 80*
1500
1,250.000 1,500,000
431.0 431.0
16,000 19,000
5 755 11.5 1,662 100' 7H 830 14.0 1,875 100'
1.750,000 574.1 23,000
680 1 16.5 2,182 120'
2.000.000 574.1 26,000 21'-triple 10 740 18.5 2.500 120*
.e66 `3 S3
80# 32'
80' 32* 80' 32* 80' 32* 83' 48' 83' 48' 96* 54' 96' 54' 96' 60* 96' 1 60'
Mech. Ex haust Dis charge
18x60 8'dia. 1,590 18x60 8' dia. 1,690 18x80 8'dia. 1,950 18x80 8'dia. 2,160 22x80 10* dia. 2.775 22x80 10* dia. 2,850 26xlO( 10* dia. 3,850 26x100 i 10* dia. 4,010 30xl2( ! 12* dia. 4,750 30x120 12' dia. 4,910
[uivalent Direct Transfer Projection Not Included.
** Adjustable.
t Burner Projections Not Included. ft Discharge
101