HEATING VENTILATING AIR CONDITIONING GUIDE 1940 open. However, the A.S.H.V.E. Code for Heating and Ventilating Garages, adopted in 1929 and revised in 1935, states that natural venti lation may be employed for the ventilation of storage sections where it is practical to maintain open windows or other openings at all times. The code specifies that such openings shall be distributed as uniformly as pos sible in at least two outside walls, and that the total area of such openings shall be equivalent to at least 5 per cent of the floor area. The code further states that where it is impractical to operate such a system of natural ventilation, a mechanical system shall be used which shall provide for either the supply of 1 cu ft of air per minute from out-of-doors for each square foot of floor area, or for removing the same amount apd discharging it to the outside as a means of flushing the garage.6 Research ' Research on garage ventilation undertaken by the A.S.H.V.E. Com mittee on Research at Washington University, St. Louis, Mo., and at the .University of Kansas, Lawrence, Kans., in cooperation with the A.S.H. V.E. Research Laboratory, and at the A.S.H.V.E. Research Laboratory has resulted in authoritative papers on the subject. Some of the conclusions from work at the Laboratory are listed in the following statements: 1. Upward ventilation results in a lower concentration of carbon monoxide at the breathing line and a lower temperature above the breathing line than does downward ventilation, for the same rate of carbon monoxide production, air change and the same temperature at the 30-in. level. 2. A lower rate of air change and a smaller heating load are required with upward than with downwardJventilation. 3. In the average case upward ventilation results in a lower concentration of carbon monoxide in the occupied portion of a garage than is had with complete mixing of the exhaust gases and the air supplied. However, the variations in concentration from point to point, together with the possible failure of the advantages of upward.ventilation to accrue, suggest the basing of garage ventilation on completejnixing and an air change sufficient to dilute the exhaust gases to the allowable concentration Of carbon monoxide. 4. The rate of carbon monoxide production by an idling car is shown to vary from 25 to 50 cfh, with an average rate of 35 cfh. 5. An air change of 350,000 cfh per idling car is required to keep the carbon monoxide concentration down tb one part in 10,000 parts of air. Code for Heating and Ventilating Garages (A.S.H.V.E. Tiiassactiuss. Vol. 35. 1929, p. 355), (A.S. H.V.E. Reprint, January, 1935). Alration Study of Garages by W. C. Randall and L. W. Leonhard (A.S.H.V.E. Transactions, Vol. 36, 1930. p.233). A.S.H.V.E. Research Report No. 874--Carbon Monoxide Concentration in Garages, by A.S. Langs- dorf and R. R. Tucker (A.S.H.V.E. Transactions, Vol. 38. 1930, p. 511). A.S.H.V.E. Research Report No. 935--Carbon Monoxide Distribution in Relation to the Ventilation of an Underground Ramp Garage, by F. C. Houghten and Paul McDermott (A.S.H.V.E. Transactions, Vol. 38. 1932. p. 439). A.S.H.V.E. Research Report No. 934--Carbon Monoxide Distribution in Relation to the Ventilation of a One-Floor Garage, by F. C- Houghten and Paul McDermott (A.S.H.V.E. Transactions. Vol. 38,1932, p. 424). A.S.H.V.E. Research Report No. 967--Carbon Monoxide Distribution in Relation to the Heating and Ventilation of a One-Floor Garage, by F. C.' Houghten and Paul McDermott (A.S.H.V.E. Trans actions, Vol. 39, 1933. p. 395). . . Carbon Monoxide'Surveys of Two Garages, by A. H. Sluss, E. K. Campbell and, Louis M. Farber (A.S.H.V.E. Transactions, Vol. 40. 1934. p. 263). 648 Chapter 38 AUTOMATIC CONTROL Purpose of Automatic Control, Definitions of Control Units and Terms, Types of Control, Central Fan Systems, Unit Systems, Control of Automatic Fuel Appliances, Residential Control Systems, Control of Refrigeration Equipment, Indus trial Processes THIS chapter is prepared with the purpose of acquainting the engi neer with the principles underlying the use of automatic control, the general types and varieties of control equipment available and their application. Automatic control, properly applied to heating, ventilating and air conditioning systems, makes possible the maintenance of desired con ditions with maximum operating economy. A properly designed and complete control system has the ability to interlock and coordinate the various functions of heating, ventilating and air conditioning in a manner impossible to accomplish with manual regulation. Automatic control is an integral and essential part of a heating, venti lating or air conditioning installation and cannot be regarded as an acces sory. In order to insure satisfactory results, the control should be designed with and incorporated in the heating, ventilating or air conditioning system. The control equipment should be given careful consideration in the planning of any installation in order that the entire system may operate together with satisfactory results. ,. In order that proper selection and application of controlling devices may be made it is important that a broad understanding' exist as to the types of control available and their principles of operation. Improper selection and application of control equipment will result in unsatis factory and inefficient operation. Specific control devices and systems are described in the Catalog Data Section. PURPOSE OF AUTOMATIC CONTROL Automatic control is normally applied to heating, ventilating or air conditioning systems: 1. To insure the maintenance of certain desired or required conditions of temperature, pressure, humidity, air motion or air distribution. 2. To serve a safety function, limiting pressures or temperatures within predetermined points, or preventing the operation of mechanical equipment unless it may function without hazard. 3. To produce economical results and thereby insure operation of the system at a minimum of expense. 649