Document N80NR8E0v2yDQZY6X1Gb4p0w

SC-ELEC-06425 274 UNIT SUBSTATION--WIRES Acme Electric Corp., Cuba, N, Y, 14727 GTE Sylvania, Ire., Electrical Equipment Group, Waltham, Mass. 02154 Sierra Switchboard Co., Menlo Park, Calif. 94025 Sorgel Electric Corp., Subsidiary of Square D Co., Milwaukee. Wis. 53204 Unicom Industries, Anaheim, Calif. 92806 Westinghouse Electric Corp., Greenville, Pa, 16125 Ztnsco Electrical Products, Los Angeles, Calif. 90012 WIRES (460 10) ZGZX Insulated wire is intended for installation and use in accordance with the National Electrical Code. Unless indicated in the individual General Information sections under the various Wire Classifications, conductor sizes range from Nos. 14 Awg to 2000 MCM inclusive. WIRES, ASBESTOS-INSULATED (460 12) ZHNV Asbestos-Insulated wires are classified and rated as follows: Type A--with asbestos insulation, 300 volts maximum, Sizes No, 14 through No. 8 Awn inclusive, copper. Type AA--with an asbestos or glass braid and asbestos insulation, 300 volts maximum, Sizes No. 14 through No. 4/0 Awg inclusive, copper. Type AI--with impregnated asbestos insulation, 300 volts maximum. Sizes No, 14 through 8 Awg inclusive, copper. Type AIA--with an asbestos or glass braid and impregnated asbestos insulation, 800 volts maximum, Sizes No. 14 Awg through 1000MCM inclusive, copper. -> LOOK FOR THE LISTING MARK *- American Insulated Wire Corp., Pawtucket, R. I, Belden Corp,, Geneva, I1L 60134 Carol Cable Co., Pawtucket, R. I. 02362 Cerro Wire & Cable Co., Division of Cerro Corporation, New Haven, Conn. 06504 Cleveland Insulated Wire Co., Cleveland 11, Ohio. Collyer Insulated Wire Co., Inc., Lincoln, R. I. Continental Wire & Cable Corp., Subsidiary of The Anaconda Co., York, Pa. 17405 Electrical Cable Div,, United States Steel Corp., Worcester, Mass. 01607 General Electric Co,, Bridgeport 2, Conn. Interstate Wire Corp., Minooka, 111. 60447 Jemco Insulated Wire Co., Joliet, III 60434 Radix Wire Co., The, Cleveland-32, Ohio. Techbestos, Inc., Moonachie, N. J. Teledyne Western Wire & Cable, Los Angeles, Calif. 90058 Triangle PWC, Inc., new Brunswick, N. .1, 08903 Westlake Insulated Wire Co,, Westlake, Ohio. WIRES, ASBESTOS-VARNISHED-CLOTH (460 13) ZIBT Asbestos-varnishad-cloth wires are classified as follows: Type AVA--an asbestos or glass braid, ami insulation consisting of varnished cloth and impregnated asbestos. Sizes No. 14 Awg through 2000MCM inclusive, copper. Type AVB--a flame-retardant cotton braid, and insulation consisting of varnished cloth and impregnated asbestos. Sizes No. 18 Awg through 2000MCM inclusive, copper, and No. 12 Awg through 1000MCM inclusive, aluminum or copper-clad aluminum. Type AVL--a lead covering, and insulation consisting of varnished cloth and impregnated asbestos. Sizes No. 14 Awg through 20Q0MCM inclusive, copper. Wires for use at voltages above SOU are inuicateo by adding numerical suflixes to the type letters, as follows; All raanufacrur certain mar Tyne AVH w<Wire* with co;. Wires with aiur The ampacif conductors. Tn< recognized for u* except that 1Z1 binding screws a are recognized li able for interm connections oni: intermixed conn- American In; Cerro Wire & Conn. 0650 Cleveland Ins Collyer Insul; Continental V York. Pa. Electrical Ca Mass. 016- General Elec Radix Wire < Techbestos. I Teledyne We Triangle PW Westlake Ins Fixture wires u Flexible Co: All conductors ? 90 C may e: Thermoplastic c care should Gasoline resists: sidered inhe rating of th Gasoline resistar extruded ny line vapors and by p "Type TFN oil at 60 0 is suitable Fixture wires 60 C maxim Tbermopla 600 v. i' Christmas* 125 v. 2 The mi sulation on the c 75 C maxim Rubber-ins 300 v. !; 600 v, 1 9u C max in Cotton-ins 300 v. : Thermopit 600 v I '04 ional :nder ilCM *'o. 8 num, - 1* . 600 loth and WIRES Wires. Asbestos-Varnished-Cloth--Continued 275 Nnmerical Malinom Working Designation Voltage 10 1000 20 2000 30 3000 40 4000 - 50 5000 All manufacturer* are listed for 600-volt wires- As stated in the individual listings, certain manufacturer* are also listed for wires with voltage rating up to 5000 volts. Tyne AVli wire may empjoy copper, or aiuminum, or copper-clad aluminum conductors. Wires with copper-clad aluminum conductor* are surface printed "AL (CU-CLAE)-1' Wires with aluminum conductors shall be surface printed "AL." The ampacity of copper-clad aluminum conductors is the same as for aluminum conductors. The wire connectors used "with copper-clad aluminum conductors shall be recognized for use with copper and aluminum conductors and shall be marked "AL-CU." except that 12-10 Awg solid copper-clad aluminum conductors may be used with wire binding screws and in pressure-plate and push-in spring-type connecting mechanisms that are recognized for use with copper conductors. Copper-clad aluminum conductors are suit able for intermixing with copper or aluminum conductors in terminals for splicing connections only when the wire connectors are specifically recognized for such use. Such intermixed connections are limited to use in dry locations. LOOK FOR THE LISTING MARK American Insulated Wire Corp., Pawtucket, R, I. Cerro Wire & Cable Co., Division of Cerro Corporation, New Haven, Conn. 06504 Cleveland Insulated Wire Co., Inc., Cleveland 11, Ohio. Coliyer Insulated Wire Co.. Inc., Lincoln, R. I. Continental Wire & Cable Corp., Subsidiary of The Anaconda Co., York, Pa. 17405 Electrical Cable Div., United States Steel Corp., Worcester, Mass. 01607 General Electric Co., Bridgeport 2, Conn. Radix Wire Co., The, Cleveland 32, Ohio, Techbestos, Inc., Moonachie, N. J. Teledyne Western Wire & Cable, Los Angeles, Calif. 90058 Triangie PWC, Inc., New Brunswick, N. J. 08903 Westlake Insulated Wire Co., Westlake, Ohio 44145 FIXTURE WIRE (460 16) 2IPR Fixture wires me isted 6bh volts, or less, as shown, ami comply with the Standard for Flexible Coid and Fixture Wire of Underwriters' .Laboratories, Inc. (TJL52). All conductors are copper except fixture wire having a temperature rating higher than 90 C may employ nick*?). Thermoplastic compounds may stiffen at temperatures below minus 10 C (14 F) and care should be used in handling at such temperatures. Gasuhne resistant wire has been tested at 30 C when immersed in gasoline. It is con sidered inherently resistant to gasoline vapors within the limits of the temperature rating of the wire type. Gasoline resistant TFN or TFFN--Indicates a TFN and TFFN conductor with a jacket of extruded nylon suitable for exposure to mineral oil, and to liquid gasoline and gaso line vapors at trilinary ambient temperature. It is identified by tag marking and by printing on the insulation or nylon jacket with the designation "Type TFN (TFFN) Gasoline and Oil Resistant I" if suitable for exposure to mineral oil at 60 C or "Type TFN (TFFN) Gasoline and Oil Resistant II" if the compound is suitable for exposure to mineral oil at 75 C. Fixture wires are classified as follows: 60 C maximum operating temperature. Tbermoplasttc-inaulated wires. 600 v. 18-16 AWG sizes: Types TF, TFF. Christmas-tree wire*. 125 v. 20-18 AWG size: Type FXT*. The maximum voitage is 300, provided that the nominal thickness of the in sulation on the conductor is 2/64 in. 75 C maximum operating temperature. Rubber-insulated, beat-resistant wires. 300 v, 18 AWG size: Types RFH-l, FFH-1. 600 v. 18-16 AWG sizes: Types RFH-2. FFH-2, 90 C maximum operating temperature. Cotton-insulated wire, 300 v. 18-10 AWG sizes: Type CF. Thermoplastic-insulated wires. 600 v. 18-16 AWG sizes: Types TFN. TFFN.