Document N73yJ9Erx9XnVazkwrrevYGw

(.) . I " -\ -i3_ - yrte, S**~- tkc&^CtL. 'Me XI. MlWCior Wildlife Project The analytical support work for the Aroolor Wildlife Project can be divided into 4 areas. | . 1. Develop sensitive and specific in-hand methods for ldentl, ' fylng Aroclor in our environment. 2. Initiate an outside toxicological test program and . provide necessary analytical methodology. ,i 3. To determine validity of methods used and the results obtained by workers In the residue area. - 4. Monitor labs doing research on environmental contamlna- tlon by Aroclors. j The following progress has been made In the following areasi 1. An F & M 4o2 High Efficiency Gas Chromatograph has been purchased and set up. This system allows two column operation and a choice of 3 detective systems - electron . ' capture, flame ionization and micro columetrlc. ' The OC electron capture system is operational and has been completely evaluated with regards to Aroclor sensi tivity and potential pesticide interferences using a QF1-Chrome Sorb W column. , 2. The second column (DC 200 Anaehrom ABS) will utilise both the flame Ionization and micro columetrlc detectors via an infinitely variable effluent splitter. The electron capture system provides an extremely sensitive method for Identifying nanogram amounts of polychlorl- ' nated biphenyls and possibly a semi-quantitative estima tion of amount present. The flame ionization micro columetrlc detector While not as sensitive, should provide a better quantitative measure. This second system Is not operational because of electronic failure and has not been completely evaluated. The characteristics of the polyohlorlnated biphenyls on the 2 different columns and 3 detectors will provide for their almost unequlvocable Identification In unknown samples. Some thin layer and column ohromatographle techniques have also been Investigated for the isolation of polychlorinated - . ' biphenyls from pesticides Which Interfere with the gas . chromatographic determination. In addition to this work, " Dr. Mleure has established the operating parameters necessary for the absolute Identification of polychlorl- . . nated biphenyls by OC/toASS. MQNS 035923 o) 14- 2, An outside toxicity study has been initiated with Indus trial Bio-Test Laboratories and the necessary analytical support work completely outlined on paper. Some tissue samples are now in hand and verification of outlined procedure will begin soon. An alternate hot analytical approach using C14 tagged Aroelor has also been outlined on paper and is available should its use be necessary. 3. After closely reviewing the available literature, 1 find it difficult to dispute the identification of the lnterferrlng peaks aB polychlorinated blphenylB. Still we have not aotually demonstrated this on real samples in the labs. For this reason a letter to the Fish and Wildlife people at Patuxent is being drafted requesting duplicate samples of some of the tissues in which they believe they have found polychlorinated biphenyl. These samples will then be subjected to an absolute OC/foASS Identification, If polychlorinated biphenyls are found, this still does not prove that Aroelors are the initial source of contamination. To help us deter mine if Aroelors are the actual source of contamination, the following experiments have been planned. a) Water solubility of Aroolor b) Incineration of Aroclorjcontaining paper c) Analysis of air, water,' and Boll samples from around our manufacturing sites. d) Feeding studies with pesticides that might be metab- ' ollzed to polyehlorinated blphenylB. 4. We have visited several government agencies in Washington todlsouss polyehlorinated biphenyls, Trips will be planned as deemed necessary.' - ' III. Industrial Hydraulic Fluids | . MCS 790. a 190 SUS Pydraul 312 type fluid was formulated for tne Japanese market. Properties are being obtained on this fluid whloh is similar in composition to Pydraul 135. After typical physical properties and fire resistance are obtained, data and a small sample will be sent to Japan and .pilot plant quantities blended;for full scale pump tests. ! Houghto-Safe 1120 - provided excellent anti-wear performance in a Viosc test in the same range as Pydraul 312 and anti wear petroleum oils. j HONS 035924