Document N2m135Gvr2XrEaB3r3nnmGGBE
FILE NAME: Goodyear (GY)
DATE: 1988 July 22 DOC#: GY068
DOCUMENT DESCRIPTION: Safety & Health Bulletin - Clearance Samples for Asbestos Removal
Industrial Hygiene Mailing List
C L UILCOX HAZARDOUS MATERIALS COORDINATOR TECH CENTER AKRON
FROM
Corporate Industrial Hygiene
5D 0B CATt
duly 22, 1988 .
SUBJECT
Clearance Samples for Asbestos Removal
If valid documentation of proper clean-up after indoor asbestos removal operations is desired, clearance samples should be collected both before and after all operations. Post removal results should be 0.01 f/cc or the level of pre-removal sampling, whichever is higher (by phase contrast microscopy). If sample levels are above the higher value, then cleaning should be conducted again with additional post clean-up samples for rvaluation.
These samples should be collected with a high flow pump running at 2 LPM for a 24 hour period. This will require plugging the pump into the charger and the charger into an appropriate outlet.
Please insert this document in Section C of your Industrial Hygiene Polices/Practices Manual.
If you have any questions, please contact Corporate Industrial Hygiene.
J L Holtshouser e8p5a31/pb
-yyf
Manager Corporate Industrial Hygiene
GY01-002529
GOOOYCAR
GLD0C1O19