May 5, 1992 Dow U.S.A. The Dow Chemical Company P 0 Box " 50 Piaouerhi'-e Loo'S.ana 7C765-0'50 Daniel Cortez Eddie Guillory Petrin Petrin Building 4106 cc: Wayne Russell Cellulose Building 4501 Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you, Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc PRODUCED FOR THE ASBESTOS DATABASE OATS; ____________________ MASTER No. 4^5%! \ DO A 114983 CONFIDENTIAL ASBESTOS MONITORING DATA RESULTS; CELLULOSE 1882 "LOD **'LOQ EXPOSURE GUIDELINES 8-HR. TWA LIMIT - 0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE# PERSONNEL DESCRIPTION DURdflIM) VQL4L) 4/30/92 13534 *551-17-4410 Insulator: Removing asbestos insulation from an exchange on wash deck - WET METHOD USED 30 76 * The proper protective clothing was worn during the job. North 7700 Respirator with HEPA (liters were worn during the job. ** LOD FIB/CC 0.03 *"LOQ FIB/CC <0.51 Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, fiie NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this Information, we will establish 100 Fibers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which is more representative of the actual fibers present} for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. DO 1 r.GNr j; tNT7h7 i LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE NS 1 3534 PLANT/DEPT. ____ MONITORING FOR:_ DATE t-bfO'fo OTHER CHEMICALS PRESENT:. SAMPLE COLLECTION MEDIA: BADGE NO.____ TYPE. TEMP/HUMIDITY: (REQUIRED FOR BADGES). CHARCOAL TUBE SIZE_________________ ""FILTER CASSETTE SIZE SILICA TUBE SIZE__________________ DRAGERTUBE TYPE_________________ OTHER __________________________________ SHIFT: (TThR. 12 HR. ""PERSONNEL SAMPLE FULL SHIFT TWA STEl/TASK AREA SAMPLE EMPLOYEE NAME___ - EMPLOYEE I.D.# <~S" I JOB CLASSIFICATION___ IH JOB CODE #_________ CONTRACTOR COMPANY _ RESPIRATOR USED? O^ES NO LvllwiRESPIRATOR MODEL / CANISTER TYPE %o^Ai'7QO MOUTH-BIT DUST "H"AhLaFl-fF-fAaCcEe / FULL-FACE AIR-LINE SC BA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING XL A jUUCLid ~ PUMP SERIAL NO. CALIBRATION DEVICE: 1 BUBBLEMETER OTHER________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: T. 7 a J~Q>- 3 _ a- sr03 ___ BEGINNING FLOW RATE AVG. 3T O'A&T:C/MIN L/MIN ENDING:!. 2. > rvJ- N 2V&U 3.__ 'arosb ENDING FLOW RATE AVG.. 0"c/min L/MIN ^ SAMPLE AVERAGE FLOW RATE i& TIME STARTED. iL'po ft* TIME STOPPED. it.'iQ___ l TOT. RUNNING TIME(MIN). ~%0 Hum** Jl1SAMPLE VOLUME (AVG FLOW X RUN TIME). _______________ ___________________________________ ANALYTICAL REPORT REFERENCE It JO-gimp's ANALYTICAL RESULTS: O. 03 Wi&- doJL^ U> O * RESTRICTED FOR USE WITHIN DOW ONLY * VP-124 uoq FORM FILLED IN BY:. I .5 r L j 00 i 1 <4 v t.j ~ j CONFTDFNTI Al