Document N2QD77Djb3Q8NJgBBz3kLdNDD

HEAT TRANSFER FLUID THERMINOL FR - Lo Temp THERMINOL FR-Lo Temp is a low temperature, fire-resistant heat transfer fluid formulated specifically for practical pumpability at -20eF. THERMINOL FR-Lo Temp permits installation of a non-pressurized system operating with a liquid that has no fire point, and will not support combustion. The recommended operating range of THERMINOL FR-Lo Temp is -20F. to 400F. and will not show measurable change after years of exposure at such temperatures. The fluid is non-corrosive with all common metals used in heat transfer system design. Monsanto Company Organic Division Functional Fluids 800 North Lindbergh Blvd. St. Louis, Missouri 63166 0593017 I TOWOLDMON0037472 WATER_PCB-00021941 TYPICAL PROPERTIES Composition Appearanoe Four Point Plash Point Plante Point Autolgnltlon Temperature Distillation Range: First drop 10* 90* Aoldlty Moisture Chlorinated biphenyls and hydrocarbons Oily, clear, nearly color less liquid -60* P. 280* P. None to boiling Over 1100* P. 432* P. 433* F. 627* P. <0.01 mgKOH/g. <50 PPM Temp. * P. -30 -20 0 40 100 200 210 300 400 Density gm/oc 1.5051** I.4985 1.4870 1.4630 1,4260 1.3665 1.3060 1,2460** Kinematic Viscosity C8, ' 653 264 65 <12.2 > 3.39 1.084 0.459 Specific Heat* Btu/lb *P. 0.2'4 0. a;?6 0.23 0.238 0.26 0.27 0.29 0.31 Thermal Conductivity* Btu/hr-ft-P 0.0633 0.0632 O.063 0.0626 0.062 0.06l .... 0.060 0.059 Vapor Pressure mm.Hg. 1.0 -- -1.1 2.7 12.6 -- 69 300 * Cal.oulated values '* Sxtrapolated values 0593018 TOWOLDMON0037473 WATER_PCB-00021942