Document N2BeBy2oNw9QGGpqrBdBm4gyw
TEN N EC 0INTER-QFFICE MEMO CHEMICALS, INC.
\
To From Subject
M, W. Williams
at Piscataway
H. B. Carr
AT Burlington
Electrical Tests for Prominsa
date November 5, 1969
copy to e. L. Kanyok File ^
Quality Control had signals crossed in replying to your request of 9/10/69 regarding standard PVC testing plus stand ard volume resistivity testing on samples submitted by Jim Hahn.
To clear up some confusion and to set the record straight, the following occurred:
1. Samples were originally sent to Flemington for analysis. 2. Since the Flemington VR instrument was not working, the
samples were forwarded to Burlington for VR testing. 3. Earl, not realizing that two of the samples were 250-12
for which the Western Electric Method is run, ran the standard VR test on all samples. 4. Tenneco standard values listed represent VR test results that Earl obtained on Flemington retained standard resins. For the 250-12 standard, the value of 20.0 represents an average of past Burlington VR results (excluding 250-12). This is where the goof occurred. Art Gallmayer thought that this value of 20 x 1012 ohm-cm represented the 250-12 standard value.
While you were acting on jumbled information in your memo to J. C. Hahn, we feel that your statement that a VR value of 20 x 1012 ohm-cm by the standard test is desirable , for electrical performance to be correct. However, we should set Jim straight on the fact a Western Electric type test (Method No. 2-4) has been run in Burlington 250-12 with a specification minimum of 1.0 x 10^ ohm-cm. For this test we average a 3.5 x 10^2 ohm-cm and this would be considered desirable for electrical performance (by this test).
Regarding the "separate test"; e.g., this Western Electric test:
1,This test was put into effect some years ago as it gave a better correlation to Compound Plant VR testing.
COLORITE 016321
\
-2-
November 5, 19&9
2. A check with Paul Gawason indicates that an excellent correl
ation still exists. 5. Earl Kanyok states that this different test causes no prob
lem to our technicians - there is no confusion over the different formulation required. 4. While 1-3 may be true, we are presently running some standard VR tests on 250-12 to determine whether a correl ation exists with the Western Electric test. When and if this is established, the Western Electric test method will be promptly dropped.
HBC/rjl
H. B. Carr
COLORITE 016322
IntW-Office Memo
TENNECO CHEMICALS, INC.
To M. W. Williams(10) At Piscataway
Date II/5/69
From H. B. Carr
At Burlington Copy to
Subject prominsa Copolymer Samples
Reference: Memo: M. W. Williams to H. B. Carr, dated 10/29/69
Per the referenced memo, relative viscosity and bound acetate testing has been completed on the two Prominsa copolymer (385 type) samples. The bound acetate testing was performed jointly by Burlington Analytical Control and by
the Flemlngton A & E Group.
The results are:
Prominsa Sample Designation
Rel. Vise.
Tenneco Spec.
$ Bound Acetate Tenneco
Burl. Flem.
Spec.
618014
1.60
1.59-1.62 14.6 14.4
13.1-14.9
618021
1.63 (1.64)
13.8 13-9
As seen in this data, the 021 sample has a slightly high relative viscosity. The bound acetate results are within specification and the lot-to-lot variation noted Is not unusual. Burlington has ranged from 13*5 to 15.1$ on the last eight lots of 385. 'It should be noted that these eight lots were produced under SPA 783 which called for a target acetate of 14 to 15$.
HBC/rjl
- "^
,
H". B. Carr
COLORITE 016323
TITLE: APPARATUS:
CHEMICALS: PROCEDURES:
TENNECO PLASTICS DIVISION
TENNECO CHEMICALS, INC.
QUALITY CONTROL
TESTING METHOD DATE:
October, 1969
METHOD NO.: 3-65
Evaluation of Triallyl Isocyanurate (TAIC)
Abbe Refractometer, Type 3L at 25C Brookfield Viscometer EVF with KV #1 Spindle Kodak Timer Waterbath 25C and 100"C Thermometer 0 - 120C Graduated cylinder 50 ml, 100 ml Beaker 600 ml, 50 ml Test tube, 19mm OD, 150 mm long; 25 mm OD, 200 mm
long Pipette, 1 ml Glass Rod
Sample to be tested Benzene, reagent grade Heptane, reagent grade Benzoyl Peroxide, 99$
A. Refractive Index @ 258C
1. pre-condition sample to 25C in a water bath. Check temperature with thermometer.
2. Measure Refractive Index.
B. Brookfield Viscosity
1. pre-condition sample to 25C in water bath.
m
2. Measure Brookfield viscosity in 600 ml beaker. Use the KV #1 Spindle.
C. Gel Test
1. Prepare fresh for each test a 10$ benzoyl peroxide solution in benzene (8.79 gm of jbenzoyl peroxide in 100 ml of benzene).
COLORITE 016324
2 METHOD NUMBER: >65
CALCULATIONS: REPORT:
2. Weigh into a previously tared 50 nil beaker 10 gm of the TAIC to be tested.
3. Pipette 1 ml of the freshly prepared 10$ benzoyl peroxide solution into the 50 ml beaker containing the TAIC.
4. Swirl well and transfer the mix into a 19 x 150 mm test tube.
5. While starting the timer, insert the test tube into a previously heated waterbath
(100*0).
6. Stir the contents in the test tube with the glass rod continuously until all the liquid has polymerized.
7. Stop the timer.
D. Polymer Content Test
1. Transfer 5 ml of the TAIC to be tested into a 25 x 200 mm test tube.
2. Add 45 ml of Heptane.
3. Shake the test tube until all the TAIC has been dissolved.
4. As soon as the TAIC has been dissolved, hold the test tube up into the light and grade.
A. Refractive Inde'x is direct reading.
B. Brookfield viscosity in CPS scale reading x 5.
C. Gel time is direct reading. D. Polymer content test is visual.
*
A. Refractive index to the fourth decimal place.
B. Brookfield viscosity to the first decimal place.
COLORITE 016325
\ 3- -
METHOD NUMBER: >65
C. Gel time is time in minutes elapsed in waterbath until polymerization.
D. Polymer content is acceptable ("pass") if the solution is clear to a slight haze. If turbid "fail".
Written by: F. W. Kanzler
Issued by: H. B. Carr Manager, Quality Control
COLORITE 016326
TENNECO PLASTICS DIVISION
\ TENNECO CHEMICALS, INC. QUALITY CONTROL TESTING METHOD DATE: April, 1968 METHOD NO.: >65
TITLE:
Evaluation of Triallyl Isocyanurate (TAIC)
APPARATUS:
Abbe Refractometer, Type 3L at 25C Brookfield Viscometer RVF with RV #L Spindle 600 ml Beaker Water Bath, 25C Thermometer 0 - 100C
CHEMICALS:
Sample to be tested Benzene
PROCEDURES:
A. Refractive Index @ 25C
1. Pre-condition sample to 25C in a water bath. Check temperature with thermometer.
2. Measure Refractive Index.
B. Brookfield Viscosity
1. Pre-condition sample to 25C in water bath.
2. Measure Brookfield viscosity. Use the RV #1 Spindle. t
CALCULATIONS: Refractive index Is direct reading. Brookfield viscosity in CPS = scale reading x 5
REPORT:
Refractive to the fourth decimal place. Bropkfield viscosity to the first decimal place.