Document N286DKjGXvXoKddG6wVzG7Mdp
Compliance Evaluation Inspection Report Buche's Gus Stop June 2024
Submitted to: U.S. ENVIRONMENTAL PROTECTION AGENCY
REGION 8 1595 Wynkoop St. Denver, CO 80202
Submitted by: Eastern Research Group. 14555 Avion Parkway, Suite 200
Chantilly, VA 20151 EPA Contract No. 68HERC21D0007
Task Order 68HERC23F0460 COMPLIANCE EVALUATION INSPECTION REPORT
Date of Report:
June 20, 2024
Date and Time of Inspection: April 29, 2024, at 4:20 pm MST
Weather:
Rainy and partly cloudy, 56 Fahrenheit
Facility Contact/Owner:
/ GF Buche Co.
Owner Address:
102 South Main Ave Wagner, SD 57380
Facility Address:
22285 SD Hwy 44 Wanblee, SD 57577
Facility Phone:
Facility ID Number:
4070017
Reason for Inspection:
Compliance Inspection
Inspector(s):
, ERG (Lead) , ERG
, Oglala Sioux Tribe UST Coordinator
Buche's Gus Stop CEI Report
ii
June 2024
TABLE OF CONTENTS
1. NARRATIVE ..................................................................................................................... 1 2. SUMMARY........................................................................................................................ 5
ATTACHMENTS
ATTACHMENT A: ATTACHMENT B: ATTACHMENT C: ATTACHMENT D: ATTACHMENT E: ATTACHMENT F: ATTACHMENT G: ATTACHMENT H: ATTACHMENT I: ATTACHMENT J:
EPA REGION 8 UST COMPLIANCE CHECKLIST PHOTOGRAPH LOG EPA NOTIFICATION OF OWNERSHIP CHANGE FOR USTS FORM TANK LEAK DETECTION RECORDS PIPING LEAK DETECTION RECORDS & ATG CERTIFICATION SPILL & OVERFILL PREVENTION TESTING RECORDS CATHODIC PROTECTION TESTING RECORDS WALKTHROUGH INSPECTION RECORDS FINANCIAL ASSURANCE DOCUMENTATION NOTICE OF INSPECTION
Buche's Gus Stop CEI Report
iii
June 2024
1. NARRATIVE
The Region 8 (R8) office of the Environmental Protection Agency (EPA) requested multiple facilities be inspected on tribal lands. Eastern Research Group (ERG) under EPA's Contract No. 68HERC21D0007, Task Order 68HERC23F0460, provided assistance to EPA in preparing for, conducting the inspection, and preparing this inspection report. ERG inspected the Buche's Gus Stop facility in Wanblee, South Dakota on April 29, 2024. The facility was last inspected on June 15, 2021.
Mr.
, contract inspector, contacted Ms.
, representative of Buche's Gus
Stop, on April 8, 2024, via telephone to notify the facility about the inspection on April 29, 2024.
The inspection verified compliance with the federal underground storage tank (UST)
requirements of Resource Conservation and Recovery Act (RCRA) Subtitle I under 40 CFR Part
280.
Upon arrival at the facility, Mr.
introduced himself as a contract inspector for EPA,
presented his credentials, and provided an in-brief to facility operator, Ms.
to explain the purpose of the inspection. The inspection team
gathered records, interviewed Ms.
and facility representatives,
and conducted a walkthrough of the site including access ports and dispensers for the USTs. Mr.
concluded with an exit brief and had Ms.
sign the Notice of Inspection. Mr.
took photographs during the inspection.
UST System Description
The Buche's Gus Stop facility, located at 22285 SD Hwy 44 in Wanblee, SD, has a two-
compartment UST that was constructed in November 1995. According to the previous EPA
inspection report and observations made during the inspection, each tank has a 6,000-gallon
capacity, contains regular unleaded gasoline, and has single-walled STI-P3 construction. The
dispensing system for each tank is pressurized piping with flexible plastic construction. While
the piping appeared to be double walled during the inspection, this was not verified. Mr.
and Mr.
completed an EPA Region 8 UST Compliance Inspection Checklist for the
USTs while on site which is included in Attachment A. Photograph #1 in Attachment B shows
the dispensers and an overview of the UST system. Attachment C includes the recent notification
form sent to the state regarding change in ownership to GF Buche Co.
UST System Records
The listing of documents reviewed for the Buche's Gus Stop inspection included the following:
1. State Ownership Change Notification Form 2. UST Leak Detection Records and Inventory 3. Tank Gauging and Line Leak Detector Test Records 4. Spill and Overfill Prevention Records 5. Cathodic Protection Records 6. Walkthrough Inspection Records 7. Financial Assurance Correspondence
Buche's Gus Stop CEI Report
1
June 2024
The facility maintains all records on site, except for the financial assurance documentation for
covering the state trust fund deductible. The corporate office for GF Buche Co located in
Wagner, SD maintains the insurance documentation. Ms.
provided the records for the
UST during the inspection.
Tank Release Detection
Releases from the tanks are detected by a Veeder-Root TLS 4C monitoring system and
associated in-tank probes that conduct automatic tank gauging (ATG) of the tanks. Attachment D
contains a compilation of the ATG continuous statistical leak detection test results for the months
since January 2023. Leak tests had passing records for both tanks at least once per calendar
month during the previous 12 months. Mr.
noted that the leak detection records were
available during each calendar month, but that the records were sometimes closer to 50 days
apart (e.g., passing record on June 9, 2023, and the next passing record not until July 31, 2023,
for Tank 1). Photograph #2 in Attachment B shows the monitoring system interface, and
Attachment D also includes a current inventory report printed during the inspection to ensure
proper monitoring system operation. Ms.
also provided a passing test record for the tank
gauging system performed by a contractor in February 2024 (see Attachment E).
Piping Release Detection
All tanks were installed with pressurized flexible plastic piping, which appeared to be double walled based on visual observation. The piping is equipped with submersible turbine pump (STP) sumps and mechanical line leak detectors (LLDs). UST Testing Services Inc conducted testing on the LLDs and also performed line tightness testing on the piping in February 2024. Attachment E includes the passing test records for the LLDs as well as passing line tightness testing records. The dispenser sumps appeared to have liquid sump sensors, but there was no indication that Buche's Gus Stop was using them for leak monitoring. Photographs #4 and #5 in Attachment B show the STP sumps for Tank 1 and Tank 2, respectively. The STP sumps had some residual water accumulated around low spots in the sump.
Spill/Overfill Prevention
The fill pipes for the USTs have spill buckets surrounding the pipes and flapper valves in the drop tubes. Photographs #6 through #8 (Tank 1) and #9 and #10 (Tank 2) in Attachment B show the fill ports and spill buckets for the respective USTs. The spill bucket for Tank 1 had approximately three inches of water present at the time of the inspection. UST Testing Services Inc. conducted testing on the spill buckets and flapper valves as spill and overfill prevention equipment in February 2024. Attachment F includes the passing test records for the spill buckets and flapper valves.
Corrosion Protection
According to facility documentation, both tanks are single-walled STI-P3 construction and
require cathodic protection, and the piping is flexible plastic construction. Ms.
provided a
record of the previous two cathodic protection tests for the tanks from February 2024 and June
2021. The exact voltage readings were not included in the records, so the inspection team was
Buche's Gus Stop CEI Report
2
June 2024
unable to verify the passing tests. Attachment G includes the cathodic protection testing records available on site from the previous two tests.
Operator Training
Buche's Gus Stop had training records for one operator at each of the Class A, B, and C levels.
Ms.
is certified as the Class A operator,
is a Class B operator, and
is a Class C operator. Mr.
noted that additional staff working in the building
should be trained as Class C operators in order to respond in case of emergencies. Photograph #3
in Attachment B shows the three training certificates posted on the wall inside the Buche's Gus
Stop building.
Walkthrough Inspections
Buche's Gus Stop only had one month of walkthrough inspections recorded in the past 12 months, which was for February 2024. Annual walkthrough records were not available at the time of the inspection. Attachment H includes the available recorded monthly walkthrough for February 2024.
Financial Assurance
Buche's Gus Stop provided a letter of correspondence between a state representative and Mr.
regarding coverage under the state trust fund for owners of USTs in South Dakota
(see Attachment I). Ms.
stated that the parent company, GF Buche Co., may have
insurance coverage or another financial mechanism to cover the $10,000 deductible for the state
program, and that the GF Buche Co. contact would have more information. Buche's Gus Stop
did not provide documentation for covering the $10,000 deductible during the inspection.
Physical Inspection
During the site visit, Mr.
and Mr.
reviewed documents on site and observed the
fill ports, STP sumps, one of the two dispenser sumps, and the ATG monitoring interface for the
two-compartment UST on site. Photograph #2 in Attachment B shows the interface for the
Veeder-Root TLS 4C ATG system. Attachment D includes tank inventory reports that Mr.
printed during the inspection to verify operation. Mr.
and Mr.
observed
the spill bucket and fill pipe for the two tanks. The spill bucket for Tank 1 contained
approximately three inches of water, and the spill bucket for Tank 2 had only about an inch or
less of water. Both spill buckets were otherwise in good condition. Flapper valves were present
in each of the fill pipes. Mr.
and Mr.
also observed the STP sumps for each of
the two tanks. Both of the STP sumps contained residual water at low points in the sump, but
otherwise appeared in good condition. The LLDs were also observed on each of the STPs.
Access ports for ATG probes were also present for each of the tanks, and no issues were noted
for these during the inspection.
There were two double-sided pump dispensers on site, and one of these, dispenser 3/4, was
opened as part of the inspection. The dispenser had what appeared to be a liquid sump sensor in
the containment area, but there was no indication that Buche's Gus Stop was actively using sump
monitoring for the dispensers. Mr.
and Mr.
did not observe signs of leaks at the
Buche's Gus Stop CEI Report
3
June 2024
time of the inspection. Photographs #11 and #12 in Attachment B show the piping beneath the dispenser.
No monitoring wells were observed at the tank field during the inspection. Vent lines are located on top of the sheltered area above the dispensers, and no obstructions or concerns were noted for the vent lines at the time of the inspection.
Buche's Gus Stop CEI Report
4
June 2024