At e* c \
c.c. G*&, Moore
DVNIl/iiS
16th Juno, 1967
Kosnre. Titanine Ltd., Titanine Work*, Sheaveshlll Avenue, London N,V. 9.
For the Attention of Mr. Cillleon
Saar Sirs,
_
With referenoo to our recent discussion over the telephone oonoemlnc the possible hazard in spraying aircraft with your uoryllo lucquer, whiol. oontaina our Aroolor 1242, I hare oade the following calculations from the
data given to me.
^opposition of Aorvlic hesln Lacouer
'
29 parte Aroolor 12^2 100 >arts Acrylic hesin ay 90 parts I iguent
179 parts
Composition of Snncr
Applied at 18,. aolidei assumo Aroolor 1242 is not included in solldc. llenoe composition of spray 1b -
} parte Aroolor 1242 12 parte Aorylio roein 6 parte Figment
62 parte Thinnera
1_ ) 18 J*rtB
Rate of Application
2 guns for 1^ hours eaoh at 10 fluid 0-./minute i.e. total quantity applied 1000 fluid ozs.
. OSW 018291
STLCOPCB4004835
tiU.<intlty of Aroolor 1242
At 5> the 1800 fluid oss. eontain 54 o.:o. Aroolor 1242. This io equivalent to 54 x 28,OOOBpraa l,652,OOOngro.
Hence if
the Aroolor 1242 is volatilised (and this in inpouaible)
the volume of air necessary to dilute to 1 mgrtn./a* i.e. the maximuw
permissible for oontinued breathing (8 hours per day on each and every day
durine working life!) is 1,652,000 a* or 50*520,000 cub. ft. during the
spraying period of lfi hours.
Dlmenolona of Hanrar
If ve take 150' * 150* x 40' as the minlmuij neoesaary to houce the aircraft and provide reasonable working acoeos we have a
volume of 900,000 oub. ft., but the actual volume of your hangar is probably auoh greuter.
Air C>aiiCTS necessary to ivo 1 mura/n^
^goofooo^' - 6> ln hour#
44 ohangee/hour.
You oan eetiaate by this approach, knowing the else of your hangar and tho oapacity of the ventilation syetea, the nunberu of changes that would apply in your case, but as 1 have enphusised above, this is to give the safe working oonosrtration for oontinued vorklnr. For oooaoional spraying periods, suoh sb ws have oonBiderod above* the oonosrtration oould go ouch higher for safely* but the workers say objeot to the sawll et concentrations of 1 part, Billion of air or over.
So far we have considered the spray only froo the Aroolor vievf>oint, but, there is about 2^ tinea as ouch thinnere to be reckoned with, and these arc not very pleasant things to breathe.
Ac regards the risk of inhaling Aroolor and solvent nists, 1 would think it desirable for those carrying out the spraying to ues a none and mouth ^respirator with a eannister suitable for absorbing organic vapours, or with a reoote breathing tube oonneoting to the outer air, but tho wearing of theae ay well raise the aooident risk, and you auet balance one against the other. Moreover, as you have had no trouble <>ith sprays containing phosphoric acid, it is probably unlikely that liquid droplets of the aorylle spray are going
OSW 018292
STLCOPCB4004836
3to cauue much trouble.
Please write to me a*:oin if there are other pointB to bo considered.
Youre fuithfully, P.V.K. RAhDY
osw 018293
STLCOPCB4004837