Document N23x9Y3ZMedLrdkxGYmmvdpNg
American Society of Heating and Ventilating Engineers Guide, igjj
case the walls must be air-tight and there should be only one smoke opening ; chimney. Cleanout, if provided, must be absolutely air-tight when closed. * nto 1
The walls of brick chimneys shall be not less than 3% in. thick (width of a ,,, size b....r..i..c...k....).....a...n...d.......s...h...a....l.l....b....e.....l..i.n....e...d......w.....i..t..h. fire-clay f-lue lining. --Fire-clay f-lue il-ining"s5Stanid?
m
manufactured from suitable refractory clay, either natural or compounded, and be adapted to withstand high temperatures and the action of flue gases. They sh of standard commercial thickness, but not less than M in. All fire-clay flue lining
1
Chapter 15
meet the standard specification of the Eastern Clay Products Association. Th
sections shall be. set in special mortar, and shall have the joints struck smooth o inside. The masonry shall be built around each section of lining as it is placed anaTM^ spaces between masonry and linings shall be completely filled with mortar. No
^ ^,,-.jbs'v;'
SOLID FUELS
flue lining shall be used. Flue lining shall start at least 4 in. below the bottom of sm pipe intakes of flues, and shall be continued the entire heights of the flues and nro'"^
at least 4 in. above chimney top to allow for a 2 in. projection of lining. The wash^I
of Coal, Coke; Combustion of Coal and Coke; Hand Firing; ^!^# 'S^mnical Stoker Firing; Storage Space for Coal; Dustless Coal.
its splay shall be formed of a rich cement mortar. To improve the draft the wash surf
should be concave wherever practical.
at?J
Flue lining may be omitted in brick chimneys, provided the walls of the chitnneJi
j i--
has been the most
are not less than 8 in. thick, and that the inner course shall.be a refractory clay brie?!
All brickwork shall be laid in spread mortar, with all joints push-filled. Exposed joint both inside and outside shall be struck smooth. No plaster lining shall be permitted)!
used fuel; it graauuny .v* I iDFidtrlyaninsproercteantitonyeafarsc.iliAtiecscoirndcinregastoe_de. sTtihmeatuesseo0f1thwe wU. S. B-u--r-e--au of
Chimneys shall extend at least 3 ft. above flat roofs and 2 ft. above the ridges ofl
peak roofs when such flat roofs or peaks are within 30 ft. of the chimney. The chimneys shall be high enough so that the wind from any direction shall not strike the top of tbit
chimney from an angle above the horizontal. The chimney shall be properly capped wittf!
`stone, terra cotta, concrete, cast iron, or other approved material; but no such caba
or coping shall decrease the flue area.
rS
There shall be but one connection to the flue to which the boiler or furnace smoke-g
pipe is attached. The boiler or furnace smoke-pipe shall be thoroughly grouted into thl
chimney.and shall not project beyond the inner surface of the flue lining.
1
The size or area of flue lining or of brick flue for warm-air furnaces depends on height of chimney and capacity of heating system. For chimneys not less than 35 ft. in height!! above grate line, the net internal dimensions of lining should be at least 7 x llj^ in.^1 for a total leader pipe area up to 790 sq. in. Above 790 and up to 1,000 sq. in. of leader! pipe area the lining should be at least 11)4 X UK in. inside. In case of brick flues not!
less than 35 ft. in height with no linings, the internal dimensions should be at least? 8 x 12 in. up to 790 sq. in. of leader area, and at least 12 x 12 in. for leader capacities! up to 1,000 sq. in. Chimneys under 35 ft. in height are unsatisfactory in operation and:^ hence should be avoided.
SMOKE TEST
The chimney flue must be smoke tight and shall be subjected to a:J smoke test by the mason contractor in the presence of the architect or ,| his representative, after the mortar has thoroughly hardened.
The method of conducting this test shall be as follows; With a good jl fire in the boiler or furnace, or in the base of the chimney, put about a)| square yard of tar paper on the fire) As soon as smoke appears at the \ top of the chimney close the top of the flue with a piece of old carpet or g wet newspapers held down by a weighted board. Keep the tar paper burning in the firepot for five minutes. The architect or his represen tative shall sign an acceptance in triplicate, stating that the chimney :$ was tight under the foregoing test, and shall give one copy to the mason 3 contractor, one copy to the heating contractor and one copy to the owner.
Mh&S, the coal and coke used for heating purposes in 1928 was;
........................................46 to 56 million tons
Anthracite-
.56 to 77 million tons
Bituminous.....
.7% million tons
>*-<"?All coaCl ookreigs.i.n..a...t.e...d---...f..r.o...m......v..e...g...e...t.a...t.i.o.- n in swampy places. This vegetation
?^decayed as it fell and built up in successive layers, in time forming peat ) trliich in turn became lignite and then under the influence of pressure and
:'heat gradually changed into coals of higher carbon content. In America xfifvitfe boals in the East have generally-developed 'further than those in the
5.;"..-,\Vest. As the coals are less developed their moisture and oxygen content
r.$ increase and their heating value decreases.
r ` .> .'a ` , . '
.
xsrj-'.kr:KINDS OF COAL
, The complex composition of coal makes it difficult to classify it into '-> r* c1ear-cut types. Its chemical composition is some indication but coals
A? having the same chemical analysis may have distinctly different burning
' . characteristics. Users are mainly interested in the available heat per /.%'pouhd of coal, in the handling and storing properties, and in the burning
;. characteristics, A description of the relationship between the qualities
. of coals and these characteristics requires considerable space; a treatment applicable to heating boilers is given in U. S. Bureau of Mines Bulletin 276.
; Fig. 1 illustrates the distribution of the kinds of coal by States and
;.:Shpws the average calorific values and the ash and moisture contents of
; a limited number purchased on the open market. Five hundred tests in
....; a small domestic boiler were made with these coals by the U. S. Bureau
.'. . ,of; Mines and the lower curves show the averages of the pounds of water evaporated per pound of coal under similar and normally good operating
co. Andbitiroienfs.description of the kinds of fuels is given in the following* but Hjlphould be recognized that there are no distinct lines of demarcation -djetween the kinds and that they graduate into each other:
241 240